Posiflex Gen9 Base Manuel utilisateur

Taper
Manuel utilisateur
1
FCC NOTES
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
CE CLASS A WARNING
This equipment is compliant with Class A of CISPR 32. In a residential environment this
equipment may cause radio interference.
AVERTISSEMENT CE CLASSE A
Cet équipement est conforme à la classe A de CISPR 32. Dans un environnement résidentiel, cet
équipement peut provoquer des interrences radio.
WARRANTY LIMITS
Warranty will terminate automatically when the machine is opened by any person other than the
authorized technicians. The user should consult his/her dealer for the problem happening.
Warranty voids if the user does not follow the instructions in application of this merchandise. The
manufacturer is by no means responsible for any damage or hazard caused by improper application.
LIMITES DE GARANTIE
La garantie prend fin automatiquement lorsque la machine est ouverte par une personne autre que
les techniciens autorisés. L'utilisateur doit consulter son revendeur pour le problème qui se produit.
La garantie s'annule si l'utilisateur ne suit pas les instructions d'application de cette marchandise.
Le fabricant n'est en aucun cas responsable de tout dommage ou danger causé par une mauvaise
application.
警告使用者
為避免電磁干擾,本產品不應安裝或使用於住宅環境。
SAFETY INSTRUCTIONS
This equipment is not suitable for use in locations where children are likely to be present.
Gen9 Base
User Manual
16080902010 Ver. A0
http://www.posiflex.com
2
CONSIGNES DE SÉ CURITÉ
Cet équipement ne convient pas à une utilisation dans des endroits où des enfants sont susceptibles
d'être presents.
WARNING
Power cord shall be connected to a socket-outlet with earthing connection.
ATTENTION
Le cordon d'alimentation doit être connecté à une prise de courant avec mise à la terre.
Package Contents
Gen9 Base Stand with VESA 100x100 Mounting Bracket..........……(x 1)
VESA 75x75 Mounting Bracket with Hinge Cover.............................(x 1)
2nd Display VESA Mounting Bracket with Hinge Cover.…………(x 1)
12V to 12V DC Power Cable for XT/PS/RT Series POS Terminal….(x 1)
24V to 24V DC Power Cable for ZT Series POS Terminal………….(x 1)
User Manual………………………………………………………..(x 1)
Views of the Gen9 Base
Overview
VESA Mounting
Bracket for Main System
Paper Roll Exit
Printer Door
3
Power Board View
Top Cover
3-Pin 24V DC-IN
Connector (Only
for Power Adapter)
4-Pin 12V DC-OUT Connector
4-Pin 12V DC-OUT
Connector
3-Pin 24V DC-OUT
Connector
Cable Cover
4
Main Parts in Accessory Pack
Installing XT/PS/RT/ZT Series to Gen9 Base
Gen 9 base support XT, PS, RT, and ZT series POS terminal. Please follow the
below procedure to install the POS terminal into Gen 9 base stand. However,
to avoid users installing by mistake, it is suggested that professional
technicians implement the installation. To get more detail information about
the installation, contact directly the Posiflex’ technical service team.
For RT series, make sure your RT terminal is Q version, which means the
VESA mount bracket of the RT terminal can be opened through two
thumbscrews. To get more detail information, please refer to the relevant user
manual on Posiflex global website: http://www.posiflex.com/en-
global/Download/download. Or contact directly the Posiflex’ technical service
team.
1. Remove the top cover and the cable cover by pressing and pulling at the
position which circled in the below picture.
Press and pull.
VESA 75x75
Mounting Bracket
with Hinge Cover
2nd Display
VESA Mounting
Bracket with
Hinge Cover
12V to 12V DC
Power Cable for
XT/PS/RT Series
POS Terminal
24V to 24V DC
Power Cable for
ZT Series POS
Terminal
5
2. Remove the rear cover of the Gen9 base stand.
3. Remove the hinge cover like the below pictures.
6
4. For RT and ZT series terminal, you have to change the VESA 100x100
mounting bracket to the VESA 75x75 mounting bracket which provided
in the packing. Remove and install the bracket with six screws.
For XT and PS series terminal, you can skip this step.
5. For XT/PS series terminal, fix the terminal to the VESA 100x100
mounting bracket with four hex socket head screws. You can find the
Allen Wrench in the package of the main system.
VESA 75x75
mounting bracket
VESA 100x100
mounting bracket
7
For RT/ZT series terminal, fix the terminal to the VESA 75x75
mounting bracket with four hex socket head screws. You can find the
Allen Wrench in the package of the main system. Please note the screws
marked A are for ZT series terminal, and screws marked B are for RT
series terminal
6. Connect the power cable to the POS terminal. Furthermore, if there is a
printer in the Gen9 base stand, connect the USB cable to the POS
terminal.
XT/PS series terminal view
VESA 75x75 mounting bracket
Screws A: for
ZT series terminal
Screws B: for RT series terminal
USB Cable of
printer (If there
is a printer.)
Power Cable
8
ZT series terminal view
RT series terminal view
7. Connect the power cable to the power board of the Gen9 base stand.
Please note that XT/PS/RT series are 12V DC-IN POS terminal, so you
have to connect the power cable to the 4-pin 12V DC-OUT connector of
the power board. Please refer to the below picture, or you can refer to the
power board view on P.3.
USB Cable of
printer (If there
is a printer.)
Power Cable
Power Cable
USB Cable of
printer (If there
is a printer.)
Cable Exit
Pass the cables
through the
VESA bracket.
4-Pin 12V DC-OUT
power connector
9
ZT series terminal, is a 24V DC-IN POS terminal, so you have to
connect the power cable to the 3-pin 24V DC-OUT connector of the
power board. Please refer to the below picture, or you can refer to the
power board view on P.3.
8. For XT/PS series terminal.
If there is no 2nd display for Gen9
base stand, close the I/O cable cover
to the XT/PS series terminal.
If there is a 2nd display for Gen9
base stand, please install the 2nd
display first before closing the I/O
cable cover.
Please find the relevant user manual
for the installation guide of the 2nd
display for Gen9 base stand.
9. Put the top cover and the cable cover to the Gen9 base stand.
I/O Cable Cover
3-Pin 24V DC-OUT
power connector
10
10. Put the hinge cover to the rear side of the terminal with both hands.
11. Put the rear cover back to the Gen9 base stand.
12. Tilt the monitor screen to your desired angle. While setting up the tilting
adjustment, be careful NOT to press on the LCD panel.
11
About 2nd Monitor for Gen9 Base
Gen 9 base support LM/TM-5015 and LM/TM-5016 2nd monitor. The detail of
installation guide is provided in the relevant monitor’s user manual. However,
to avoid users installing by mistake, it is suggested that professional
technicians implement the installation. To get more detail information about
the installation, contact directly the Posiflex’ technical service team.
Installing the Optional Printer into Gen 9 Base Stand
Follow the below step to install the PP-7900 printer into Gen 9 base stand.
However, to avoid users installing by mistake, it is suggested that professional
technicians implement the installation. To get more detail information about
the installation of the printer, contact directly the Posiflex’ technical service
team.
1. Hold the concave portion of the cable cover with thumb, as shown in the
circled portion of the figure, and then remove the cable cover in the
direction indicated by the arrow in the below picture.
2. Fix the bottom tray bracket to the bottom side of the printer with two
M2.5 screws. Please fix PP-7900 printer into the screw holes marked B.
Remove
The screw holes marked B
12
3. Install the printer to the GEN 9 base stand like the below picture. Make
sure the positioning plunger is well installed into the positioning hole.
If you want to remove the printer, please pull the plunger upwards on
the rear side and then push the printer out.
4. Remove the top cover and the cable cover by pressing and pulling at the
position which circled in the below picture.
Press and pull.
Push the
printer.
Pull the plunger.
Push the
printer.
13
5. Remove the rear cover of the Gen9 base stand.
6. Remove the hinge cover by releasing the hooks like the below pictures.
7. Connect the 24V power cable and the USB cable to the printer.
14
8. (1) Connect the other side of the power cable to one of the 24V DC-OUT
connector.
(2) Pass the USB cable through the cable exit, and then connect the other
side of the USB cable to the POS system.
9. Put the top tear cover and the cable cover to the Gen9 base stand.
10. Put the main system hinge cover to the rear side of the terminal with both
hands.
24V DC-OUT
Connector
15
11. Put the rear cover back to the Gen9 base stand.
Driver Download
Please download the relevant driver that you need from the Posiflex website
(http://www.posiflex.com/en-global/Download/download).
Specifications
Gen9 Base
Thermal Printer
(Optional)
PP-7900
Power Source
24V/120V power adapter
Power Board
1 x 24V DC-IN connector (only for power adapter)
2 x 24V DC-OUT connector
2 x 12V DC-OUT connector
Mechanical
1. VESA 100x100 mounting bracket (default), for XT
and PS series terminal
2. VESA 75x75 mounting bracket (provided as
accessories), for RT and ZT series terminal
Screws marked A are for ZT series terminal
Screws marked B are for RT series terminal
2nd Display
(Optional)
LM/TM-5015, LM/TM-5016
Environmental
Requirements
OperatingC 40°C , 20%RH - 90%RH
Storage-20°C 70°C, 10%RH - 90%RH
Regulatory
CE/FCC
16
Outline Dimension
The product information and specifications are subject to change without
prior notice. To get the detailed information on Gen9 Base, please check this
model from Posiflex Global Website (http://www.posiflex.com/en-
global/Download/download).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Posiflex Gen9 Base Manuel utilisateur

Taper
Manuel utilisateur