Simplicity 030471-02 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Not for
Reproduction
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WISCONSIN, U.S.A.
Manual No. 80010760 Revision -
Portable Generator
Operator’s Manual
This generator is certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04
(motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers’ Association)
standard PGMA G200 (Standard for Testing and Validating Performance of Portable Generators).
Not for
Reproduction
2 BRIGGSandSTRATTON.COM
Thank you for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you’ve placed your confidence
in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs &
Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generator products
and how to avoid them. This generator is designed and intended only for supplying electrical power for operating compatible
electrical lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read
and understand these instructions thoroughly before attempting to start or operate this equipment. Save these original
instructions for future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final
assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There
are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact
Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at BRIGGSandSTRATTON.COM.
Generator
Model Number
Revision
Serial Number
Engine
Model Number
Type Number
Code Number
Date Purchased
Copyright © 2014. Briggs & Stratton Power Products Group, LLC
Milwaukee, WI, USA. All rights reserved.
BRIGGS & STRATTON POWER PRODUCTS is a registered
trademark of Briggs & Stratton Corporation
Milwaukee, WI, USA
Not for
Reproduction
3
Safe Operation Checklist
Safe operation of the portable generator requires the completion of the following tasks:
Carbon Monoxide (CO) Alarm
Carbon monoxide (CO) alarm(s) in working order.
Smoke Alarm
Smoke alarm(s) in working order.
Generator Location
Generator placed in a Carbon Monoxide (CO) safe zone. See Generator Location to reduce the Risk of Carbon Monoxide
Poisoning.
Generator placed in a fire safe zone. See Generator Location to reduce the Risk of Fire.
Generator located on flat and level surface.
Oil and Fuel
Engine has proper oil level. See Verify Engine Oil Level.
Fuel tank filled at or below baffle. See Add Fuel.
Inspect fuel lines, tank, cap and fittings each time before using generator. DO NOT use if fuel leak or damage is found.
Electrical
When connecting to a buildings electrical system install listed transfer equipment. See Connecting to a Building’s
Electrical System.
Electrical cords are rated for intended loads. See Cord Sets and Receptacles.
Electrical cords do not run through doorways, windows, holes in ceilings, walls or floors.
Inspect electrical cords thoroughly before each use. DO NOT use if damaged.
All labeled electrical cord safeties are understood and being followed.
Operation
Start engine. See Starting the Engine.
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Table of Contents
Safe Operation Checklist...........................3
Operator Safety .................................5
Safety Labels ................................................5
Equipment Description.........................................7
Important Safety Information....................................7
Assembly .................................... 10
Unpack Generator ...........................................10
Install Wheel Kit.............................................10
Attach Negative Battery Cable ..................................10
Verify Engine Oil Level ........................................11
Add Fuel...................................................11
System Ground .............................................11
Connecting to a Building’s Electrical System.......................11
Portable Generator Location ...................................12
Features and Controls............................ 15
Cord Sets and Receptacles ....................................16
Battery Charger .............................................16
Operation .................................... 17
Starting the Engine...........................................17
Connecting Electrical Loads....................................18
Stopping the Engine..........................................18
Low Oil Shutdown ...........................................18
Cold Weather Operation.......................................18
Don’t Overload Generator......................................20
Maintenance .................................. 21
Maintenance Schedule ........................................21
Generator Maintenance .......................................21
Battery Maintenance..........................................21
Fuel Valve Maintenance .......................................22
Engine Maintenance..........................................22
Storage....................................................25
Troubleshooting................................ 26
Schematic - Model 030470 (7000 Watt) ..........................28
Schematic - Model 030471 (8000 Watt) ..........................29
Warranty..................................... 30
Generator Owner Warranty ....................................30
Specifications ................................. 32
Product Specifications ........................................32
Common Service Parts .......................................32
Not for
Reproduction
5
Operator Safety
Safety Labels
The generator safety labels shown below and on the next page are placed on your portable generator to draw attention to
potential safety hazards.
202997
Not for
Reproduction
6 BRIGGSandSTRATTON.COM
Not for
Reproduction
7
Equipment Description
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
The generator is an engine-driven, revolving field, alternating
current (AC) generator equipped with a voltage regulator.
The voltage regulator is designed to automatically maintain
a constant output voltage level. It was designed to supply
electrical power for operating compatible electrical lighting,
appliances, tools and motor loads. The generator’s revolving
field is driven at about 3600 rpm by a single cylinder engine.
NOTICE
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices connected
to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Every effort has been made to ensure that the information
in this manual is both accurate and current. However, the
manufacturer reserves the right to change, alter or otherwise
improve the generator and this documentation at any time
without prior notice.
The Emission Control System for this generator is warranted
for standards set by the Environmental Protection Agency
and the California Air Resources Board.
This spark ignition system complies with the Canadian
standard ICES-002.
Important Safety Information
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard. The warnings in
this manual, and the tags and decals affixed to the unit are,
therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that
it is safe for you and others. You must also make sure that
the procedure, work method or operating technique that you
choose does not render the generator unsafe.
Safety Symbols and Meanings
The safety alert symbol indicates a potential personal
injury hazard. A signal word (DANGER, WARNING, or
CAUTION) is used with the alert symbol to designate a
degree or level of hazard seriousness. A safety symbol may
be used to represent the type of hazard. The signal word
NOTICE is used to address practices not related to personal
injury.
DANGER indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING indicates a hazard which, if not avoided,
could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE address practices not related to personal injury.
Fire
Explosion
Toxic Fumes
Hot Surface
Moving Parts
Electrical Shock
Kickback
Flying Objects
Operator’s Manual
Not for
Reproduction
8 BRIGGSandSTRATTON.COM
WARNING The engine exhaust from this product
contains chemicals known to the State of California to
cause cancer, birth defects, or other reproductive harm.
WARNING Certain components in this product and
related accessories contain chemicals known to the State
of California to cause cancer, birth defects or other
reproductive harm. Wash hands after handling.
WARNING
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury.
WARNING Fuel and its vapors are extremely
flammable and explosive which could
cause burns, fire or explosion resulting
in death or serious injury.
WHEN ADDING OR DRAINING FUEL
Turn generator engine OFF and let it cool at least 2 minutes
before removing fuel cap. Loosen cap slowly to relieve pressure
in tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
Check fuel lines, tank, cap and fittings frequently for cracks or
leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are in
place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT operate this product inside any building, carport,
porch, mobile equipment, marine applications, or enclosure.
DO NOT tip engine or equipment at angle which causes fuel to
spill.
DO NOT stop engine by moving choke control to “Choke
position
( ).
WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT
Transport/move/repair with fuel tank EMPTY or with fuel shutoff
valve OFF.
DO NOT tip engine or equipment at angle which causes fuel to
spill.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers, or other appliances that have pilot light or other ignition
source because they could ignite fuel vapors.
WARNING Starter cord kickback (rapid retraction)
will pull hand and arm toward engine faster than
you can let go which could cause broken bones,
fractures, bruises, or sprains resulting in serious
injury.
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
WARNING POISONOUS GAS HAZARD. Engine
exhaust contains carbon monoxide, a poisonous
gas that could kill you in minutes. You CANNOT
smell it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be exposed to carbon
monoxide gas.
Operate this product ONLY outside far away from windows,
doors and vents to reduce the risk of carbon monoxide gas
from accumulating and potentially being drawn towards
occupied spaces.
Install battery-operated carbon monoxide alarms or plug-in
carbon monoxide alarms with battery back-up according to
the manufacturer’s instructions. Smoke alarms cannot detect
carbon monoxide gas.
DO NOT run this product inside homes, garages, basements,
crawlspaces, sheds, or other partially-enclosed spaces even
if using fans or opening doors and windows for ventilation.
Carbon monoxide can quickly build up in these spaces and can
linger for hours, even after this product has shut off.
ALWAYS place this product downwind and point the engine
exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this product,
shut it off and get to fresh air RIGHT AWAY. See a doctor. You
may have carbon monoxide poisoning.
Not for
Reproduction
9
NOTICE
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices connected
to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting electrical
loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
NOTICE
Improper treatment of generator could damage it
and shorten its life.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact
local service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect them
from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
WARNING Starter and other rotating parts could
entangle hands, hair, clothing, or accessories
resulting in serious injury.
NEVER operate generator without protective housing or covers.
DO NOT wear loose clothing, jewelry or anything that could be
caught in the starter or other rotating parts.
Tie up long hair and remove jewelry.
CAUTION Excessively high operating speeds could
result in minor injury.
Excessively low operating speeds impose a heavy load.
DO NOT tamper with governor spring, links or other parts
to increase engine speed. Generator supplies correct rated
frequency and voltage when running at governed speed.
DO NOT modify generator in any way.
WARNING
Generator voltage could cause electrical
shock or burn resulting in death or serious
injury.
Use listed transfer equipment, suitable for the intended use,
to prevent backfeed by isolating generator from electric utility
workers.
When using generator for backup power, notify utility company.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel
tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5feet (1.5m) of clearance on all sides of
generator including overhead.
It is a violation of California Public Resource Code, Section
4442, to use or operate the engine on any forest-covered,
brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined in Section
4442, maintained in effective working order. Other states or
federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer, or dealer
to obtain a spark arrester designed for the exhaust system
installed on this engine.
Replacement parts must be the same and installed in the same
position as the original parts.
WARNING Unintentional sparking could cause fire or
electric shock resulting in death or
serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Not for
Reproduction
10 BRIGGSandSTRATTON.COM
Assembly
Your generator requires some assembly and is ready for use
after it has been properly serviced with the recommended
fuel and oil level is verified.
If you have any problems with the assembly of your generator,
please call the generator helpline at (800) 743-4115. If calling
for assistance, please have the model, revision, and serial
number from the identification label available.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from
top to bottom.
4. Leave generator on carton to install wheel kit.
The generator is supplied with:
Operator’s manual
Battery float charger
Wheel kit
Keys (2)
Install Wheel Kit
NOTICE Wheel kit is not intended for over-the-road use.
You will need the following tools to install these
components:
13 mm and 19 mm wrench
Socket wrench with 10 mm and 16 mm sockets
Install the wheel kit as follows:
1. Tip generator so that engine side is down.
2. Slide axle stud (A) through mounting bracket with
threaded end facing out.
3. Insert retaining pin (B) through hole on axle stud.
4. Slide a wheel (C) over axle stud.
NOTICE Be sure to install wheel with raised hub inboard.
5. Attach wheel to axle stud with a washer (D), lock
washer (E) and nut (F). Tighten with a 16mm socket
wrench and 19mm wrench.
6. Place hub cap (G) into center of wheel and push until it
snaps into place.
7. Repeat steps 2 through 6 to secure second wheel.
8. Line up holes in support leg (H) with holes in generator
frame.
9. Attach support leg using 4 capscrews (J) and 4 hex
nuts (K). Tighten with a 10mm socket wrench and
13mm wrench.
10. Return generator to normal operating position (resting
on wheels).
Attach Negative Battery Cable
Your unit is equipped with electric start capability but can be
started manually. If you choose not to use the electric start
feature, you do not need to connect the negative battery cable.
The sealed battery on the generator pre–installed except for
the negative (black) battery cable.
To install:
1. Cut off tie wrap securing loose end of negative (black)
cable.
2. Using 8 mm or 5/16” wrenches, remove nut (H), lock
washer (J) and flat washer (K) on negative battery
terminal (—).
3. Slide negative battery cable (L) over screw (M) on
negative terminal.
4. Reattach washer and nut and tighten.
5. Verify that connections to battery and generator are
tight and secure.
NOTICE If your battery is discharged, charge prior to use
following the instructions in the section Battery Charger.
WARNING Battery posts, terminals and related
accessories contain lead and lead compounds - chemicals
known to the State of California to cause cancer and
reproductive harm. Wash hands after handling.
B
G
C
D
A
E
F
K
J
H
M
L
H
J
K
Not for
Reproduction
11
Verify Engine Oil Level
The generator engine is shipped from the factory filled with
oil (API SJ or higher 10W-30). This allows for generator
operation in the widest range of temperature and climate
conditions. Before starting the engine, check oil level and
ensure that engine is serviced as described in Maintenance.
NOTICE Any attempt to crank or start the engine before
it has been properly filled with the recommended oil could
result in equipment failure.
Refer to Maintenance for oil fill information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
NOTICE See Oil in the Maintenance section to review oil
recomendations. Verify provided oil in engine is the correct
viscosity for current ambient temperature.
Add Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
A minimum of 87 octane/87 AKI (91 RON). For high
altitude use, see High Altitude.
• Gasoline with up to 10% ethanol (gasohol) is acceptable.
NOTICE Use of unapproved fuels could damage generator
and voids warranty.
DO NOT use unapproved gasoline such as E15 and E85.
DO NOT mix oil in gasoline or modify engine to run on alternate fuels.
To protect the fuel system from gum formation, mix in a fuel
stabilizer when adding fuel. See Storage. All fuel is not the
same. If you experience starting or performance problems after
using fuel, switch to a different fuel provider or change brands.
This engine is certified to operate on gasoline. The emission
control system for this engine is EM (Engine Modifications).
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded gasoline (A) to fuel tank (B).
Be careful not to fill above the baffle (C). This allows
adequate space for fuel expansion as shown.
3. Install fuel cap and let any spilled fuel evaporate before
starting engine.
High Altitude
At altitudes over 5,000 feet (1524 meters), a minimum
85octane / 85 AKI (89 RON) gasoline is acceptable. To
remain emissions compliant, high altitude adjustment is
required. Operation without this adjustment will cause
decreased performance, increased fuel consumption, and
increased emissions. See an authorized dealer for high
altitude adjustment information. Operation of the engine at
altitudes below 2,500 feet (762 meters) with the high altitude
kit is not recommended.
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to the
AC neutral wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there
may be additional regulations which must be observed.
Connecting to a Building’s Electrical System
Connections for standby power to a building’s electrical
system must use a listed transfer switch installed by a
current licensed electrician. The connection must isolate the
generator power from the utility power and must comply
with all applicable laws and electrical codes.
FUEL
TANK
C
B
A
WARNING
Generator voltage could cause electrical
shock or burn resulting in death or serious
injury.
Use listed transfer equipment, suitable for the intended use,
to prevent backfeed by isolating generator from electric utility
workers.
When using generator for backup power, notify utility company.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
WARNING Fuel and its vapors are extremely flammable
and explosive which could cause burns,
fire or explosion resulting in death or
serious injury.
WHEN ADDING FUEL
Turn generator engine OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
Check fuel lines, tank, cap and fittings frequently for cracks or
leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
Not for
Reproduction
12 BRIGGSandSTRATTON.COM
Portable Generator Location
Before starting the portable generator there are two equally
important safety concerns regarding carbon monoxide (CO)
poisoning and fire that must be addressed.
NOTICE Satisfying the RISK OF CARBON MONOXIDE
POISONING location requirements may not satisfy the fire
location requirements. Satisfying the RISK OF FIRE location
requirements may not satisfy the CARBON MONOXIDE
POISONING location requirements.
Operation Location of Portable Generator to REDUCE
THE RISK OF CARBON MONOXIDE POISONING
All fossil fuel burning equipment, such as a portable
generator, contains carbon monoxide (CO) gas in the engine
exhaust, a poisonous gas that could kill you in minutes.
You CANNOT smell it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be exposed to carbon
monoxide gas. The following must be completed prior to
starting the portable generator engine:
By law it is required in many states to have a Carbon
Monoxide (CO) alarm (A) in operating condition in
your home. Install/maintain battery-operated carbon
monoxide alarms or plug-in carbon monoxide alarms
with battery back-up according to the manufacturer’s
instructions. A CO alarm is an electronic device that
detects hazardous levels of CO. When there is a buildup
of CO, the alarm will alert the occupants by flashing
visual indicator light and alarm. Smoke alarms cannot
detect CO gas.
Operate this product ONLY outside far away from
windows, doors and vents to reduce the risk of carbon
monoxide gas from accumulating and potentially being
drawn towards occupied spaces.
DO NOT run this product inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for
hours, even after this product has shut off.
Your neighbor(s) home may be exposed to the engine
exhaust from your portable generator and must be
considered when deciding on a location for the safe
operation of your portable generator.
ALWAYS place this product downwind and point the
engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this
product, shut it off and get to fresh air RIGHT AWAY. See a
doctor. You may have carbon monoxide poisoning.
A
Not for
Reproduction
13
EXAMPLE OF LOCATION TO REDUCE THE RISK OF CARBON MONOXIDE POISONING
DO NOT OPERATE IN ANY OF THE FOLLOWING LOCATIONS
Only use OUTSIDE and
FAR AWAY from windows,
doors and vents.
Direct exhaust AWAY
from windows, doors,
and vents.
KEEP
FAR AWAY
CO Alarm
in Living Areas
E
X
H
A
U
S
T
(
C
O
)
Generator too
close to home and
exhaust directed
towards windows,
doors and vents.
Garage
Attic
Living Area
Basement
Crawlspace
Entryway,
Porch
E
X
H
A
U
S
T
(
C
O
)
Not for
Reproduction
14 BRIGGSandSTRATTON.COM
EXAMPLE OF LOCATION TO REDUCE THE RISK OF FIRE
Operation Location of Portable Generator to REDUCE
THE RISK OF FIRE
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death or serious injury.
Portable generator must be at least 5feet (1.5m) from any
structure, overhang, trees, windows, doors, any wall opening,
shrubs, or vegetation over 12 inches (30.5 cm) in height.
DO NOT place portable generator under a deck or other type of
structure that may confine airflow.
Smoke alarm(s) MUST be installed and maintained indoors
according to the manufacturer’s instructions/recommendations.
Carbon monoxide alarms cannot detect smoke.
DO NOT place portable generator in manner other than shown.
Direct exhaust AWAY from
windows, doors, and vents.
E
X
H
A
U
S
T
(
C
O
)
5 ft. (1.5 m) min.
5 ft. (1.5 m) min.
Not for
Reproduction
15
Features and Controls
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
A - Start Switch — Turn key to start (
) position to start
the engine. Turn key to OFF (0) position to switch off
engine.
B - Hour Meter — Displays and records how many hours
your generator has run (up to 9,999.9).
C - Rocker Switch Circuit Breaker — The 120/240Volt AC,
30A locking receptacle is provided with a 2 pole rocker
switch circuit breaker to protect the generator against
electrical overload.
D - Choke Control — Used when starting a cold engine.
E - Battery Float Charger Jack — Use battery float charger
jack to keep the starting battery charged and ready for
use.
F - 120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120and/or 240Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.
G - 120 Volt AC, 20 Amp, Duplex Receptacle — May be
used to supply electrical power for the operation of
120Volt AC, 20Amp, single phase, 60 Hz electrical,
lighting, appliance, tool and motor loads.
H - Circuit Breakers (AC) — The 120 Volt AC, 20A duplex
receptacles are provided with “push to reset” circuit
breakers to protect the generator against electrical
overload.
J - Oil Fill Cap/Dipstick — Check and add engine oil here.
K - Oil Drain Plug — Drain engine oil here.
L - Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
M - Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
N - Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
P - Recoil Starter — Used to start the engine manually.
R - Fuel Valve Used to turn fuel supply on and off to
engine.
S - Fuel Tank — Capacity of seven (7) U.S. gallons (26.5 l).
Items Not Shown:
Engine Identification — Provides model, type and code
of engine. Please have these readily available if calling for
assistance.
Identification Label — Provides model and serial number
of generator. Please have these readily available if calling for
assistance.
A
C
S
M
B
D
E
F
G
H
J
K
L
P
R
N
Not for
Reproduction
16 BRIGGSandSTRATTON.COM
Cord Sets and Receptacles
Use only high quality, well-insulated, grounded extension
cords with the generator’s receptacles. Inspect extension
cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator’s manuals of devices for the
manufacturer’s recommendations.
A double pole rocker switch main circuit breaker is provided
to protect the locking receptacle. If this circuit breaker is
tripped, all receptacles are disconnected.
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same 4-wire cord if you plan to
run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 7200 watts of power (7.2kW) at
30 Amps for 240 Volts or two independent 120 Volt loads at
30 Amps each. The outlet is protected by a two pole rocker
switch circuit breaker.
NOTICE
Receptacles may be marked with rating value
greater than generator output capacity.
NEVER attempt to power a device requiring more amperage than
generator or receptacle can supply.
DO NOT overload the generator. See Don’t Overload Generator.
120 Volt AC, 20 Amp, Duplex Receptacles
The generator has two 120 Volt, 20 Amp duplex receptacles.
The receptacles are protected against overload by push-to-
reset circuit breakers.
Use each receptacle to operate 120Volt AC, single-phase,
60Hz electrical loads requiring up to 2,400watts (2.4kW) at
20Amps of current. Use cord sets that are rated for 125Volt
AC loads at 20Amps (or greater). Inspect cord sets before
each use.
Battery Charger
Use battery float charger jack to keep the starting battery
charged and ready for use. Battery charging should be done
in a dry location, such as inside a garage.
1. Plug charger into unit’s “Battery Float Charger” jack,
which is located next to the start switch. Plug battery
charger into a 120Volt AC wall receptacle.
2. Unplug charger from unit and wall outlet when generator
is being started and while it is in operation.
3. Keep this charger plugged in when generator is not in
use to prolong battery life. The charger has a built in
float equalizer and will not overcharge the battery, even
when plugged in for an extended period of time.
NOTICE See Battery Maintenance for additional information.
WARNING Damaged or overloaded electrical cords
could overheat, arc, and burn resulting in death
or serious injury.
ONLY use cords rated for your loads.
Follow all safeties on electrical cords.
Inspect cord sets before each use.
240V
120V
120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-30
Ground (Green)
4-Wire Cord Set
Not for
Reproduction
17
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
NOTICE Failure to start and operate the unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn the fuel valve (A) to the ON (I) position.
3. Pull choke control out to close choke ( ).
4A. For electric starting, turn and hold key in start switch
to start ( ) position until generator starts. To prolong
the life of starter components, DO NOT hold key in start
( ) position for more than 5seconds, and pause for at
least 30seconds between starting attempts.
If engine starts, proceed to step 6.
If engine fails to start, proceed to step 5.
NOTICE If battery is discharged, use manual starting
instructions.
4B. For manual starting, turn key in start switch to run (I)
position, grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly one time only to
start engine.
If engine starts, proceed to step 6.
If engine fails to start, proceed to step 5.
5. Push in the choke handle half way, turn key in start
switch to run (I) position and pull recoil handle twice or
turn and hold key in start switch to start (
) position
as described in step 4A.
If engine fails to start, repeat steps 3 thru 4.
6. Open the choke gradually as the engine warms up by
pushing in on the choke handle.
NOTICE If engine floods, push choke handle all the way in
and crank until engine starts.
NOTICE If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase. This
unit may be equipped with a low oil protection device. If so,
oil must be at proper level for engine to start.
A
WARNING Starter cord kickback (rapid retraction)
will pull hand and arm toward engine faster than
you can let go which could cause broken bones,
fractures, bruises, or sprains resulting in serious
injury.
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel
tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5feet (1.5m) of clearance on all sides of
generator including overhead.
It is a violation of California Public Resource Code, Section
4442, to use or operate the engine on any forest-covered,
brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined in Section
4442, maintained in effective working order. Other states or
federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer, or dealer
to obtain a spark arrester designed for the exhaust system
installed on this engine.
Replacement parts must be the same and installed in the same
position as the original parts.
Not for
Reproduction
18 BRIGGSandSTRATTON.COM
Connecting Electrical Loads
1. Let engine stabilize and warm up for a few minutes
after starting.
2. Ensure circuit breaker on control panel is in ON (I)
position.
3. Plug in and turn on the desired 120 and/or 240Volt
AC, single phase, 60Hz electrical loads.
NOTICE When plugging into the 120 Volt receptacles, plug
items to be powered in sequence as shown below.
NOTICE
DO NOT connect 240Volt loads to the 120Volt duplex
receptacles.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See Don’t
Overload Generator.
NOTICE
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices connected
to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting electrical
loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Turn key in start switch to OFF (0) position.
4. Move fuel valve to OFF (0) position.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil switch will
stop the engine. Check oil level with dipstick.
If oil level is between ADD and FULL mark on dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Briggs & Stratton Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below ADD mark on dipstick:
1. Add oil to bring level to FULL mark.
2. Restart engine and if the engine stops again a low oil
condition may still exist. DO NOT try to restart the
engine.
3. Contact an Authorized Briggs & Stratton Service Dealer.
4. DO NOT operate engine until oil level is corrected.
Cold Weather Operation
Under certain weather conditions (temperatures below 40°F
[4°C] combined with high humidity), your generator may
experience icing of the carburetor and/or the crankcase
breather system. To reduce this problem, you need to
perform the following:
1. Make sure generator has clean, fresh fuel.
2. Turn the fuel valve to the ON (I) position.
3. Use SAE 5W-30 oil.
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following Maintenance Schedule in
Maintenance section.
6. Shelter unit from elements.
WARNING Fuel and its vapors are extremely flammable
and explosive which could cause burns,
fire or explosion resulting in death or
serious injury.
DO NOT stop engine by moving choke lever to CHOKE position
( ).
1
4
3
2
Not for
Reproduction
19
Creating a Temporary Cold Weather Shelter
1. For temporary shelter, the original shipping carton can
be used.
2. Cut off top carton flaps and one long side of carton to
expose muffler side of unit. If required, tape up other
sides of carton to fit over generator as shown.
NOTICE If required, remove wheel kit to fit carton over
generator as shown.
3. Cut appropriate slots to access receptacles of unit.
4. Face exposed end away from wind and elements.
5. Locate generator as described in the section Generator
Location. Keep exhaust gas from entering a confined
area through windows, doors, ventilation intakes or
other openings.
6. Start generator as described in the section Starting
the Engine, then place carton over generator. Keep at
least 5 ft. (1.5 m) clearance on all sides of generator
including overhead with shelter in place.
7. Remove shelter when temperatures are above 40°F
[4°C].
8. Turn engine OFF and let cool two (2) minutes before
refueling. Let any spilled fuel evaporate before starting
engine.
Building a Cold Weather Shelter
1. Using non combustible material with a fire rating of at
least one hour, build a shelter that will enclose three
sides and the top of the generator. Make sure muffler
side of generator is exposed.
NOTICE Contact your local building material supplier for
non combustible materials with a fire rating of at least one
hour.
NOTICE Be sure shelter can easily be repositioned for
change in wind direction.
2. DO NOT enclose generator any more than shown.
Shelter should hold enough heat created by the
generator to prevent icing problem.
NOTICE If a wheel kit is installed on the generator, enlarge
shelter accordingly.
3. Follow steps 3 through 8 as described previously in
Creating a Temporary Cold Weather Shelter.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel
tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5feet (1.5m) of clearance on all sides of
generator including overhead.
Remove shelter when temperatures are above 40°F [4°C].
WARNING POISONOUS GAS HAZARD. Engine
exhaust contains carbon monoxide, a poisonous
gas that could kill you in minutes. You CANNOT
smell it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be exposed to carbon
monoxide gas.
Operate this product ONLY outside far away from windows,
doors and vents to reduce the risk of carbon monoxide gas
from accumulating and potentially being drawn towards
occupied spaces.
Install battery-operated carbon monoxide alarms or plug-in
carbon monoxide alarms with battery back-up according to
the manufacturer’s instructions. Smoke alarms cannot detect
carbon monoxide gas.
DO NOT run this product inside homes, garages, basements,
crawlspaces, sheds, or other partially-enclosed spaces even
if using fans or opening doors and windows for ventilation.
Carbon monoxide can quickly build up in these spaces and can
linger for hours, even after this product has shut off.
ALWAYS place this product downwind and point the engine
exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this product,
shut it off and get to fresh air RIGHT AWAY. See a doctor. You
may have carbon monoxide poisoning.
Wind
Not for
Reproduction
20 BRIGGSandSTRATTON.COM
Don’t Overload Generator
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is the
amount of power your generator must produce to keep
your items running. See Wattage Reference Guide.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge (Starting) Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity, as
described above.
* Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge (Starting)
Watts
Essentials
Light Bulb - 75 watt 75 -
Deep Freezer 500 500
Sump Pump 800 1200
Refrigerator/Freezer - 18 Cu. Ft. 800 1600
Water Well Pump - 1/3 HP 1000 2000
Heating/Cooling
Window AC - 10,000 BTU 1200 1800
Window Fan 300 600
Furnace Fan Blower - 1/2 HP 800 1300
Kitchen
Microwave Oven - 1000 Watt 1000 -
Coffee Maker 1500 -
Electric Stove - Single Element 1500 -
Hot Plate 2500 -
Family Room
DVD/CD Player 100 -
VCR 100 -
Stereo Receiver 450 -
Color Television - 27” 500 -
Personal Computer w/17” monitor 800 -
Other
Security System 180 -
AM/FM Clock Radio 300 -
Garage Door Opener - 1/2 HP 480 520
Electric Water Heater - 40 Gallon 4000 -
DIY
Quartz Halogen Work Light 1000 -
Airless Sprayer - 1/3 HP 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 HP 1000 1000
Circular Saw - 7 1/4” 1500 1500
Miter Saw - 10” 1800 1800
Table Planer - 6” 1800 1800
Table Saw/Radial Arm Saw - 10” 2000 2000
Air Compressor - 1-1/2 HP 2500 2500
Tool or Appliance Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500
Light (75 Watts) 75
3075 Total
Running Watts
1800 Highest
Additional Surge Watts
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Simplicity 030471-02 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur