INSTALLATION
GAS HOOK-UP
GAS REQUIREMENT
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating
plate agrees with that of the supply. The rating plate is located underneath the unit bottom. Never connect an
unregulated gas line to the appliance. You must use the gas regulator provided with the unit, even if the supply
is controlled.
An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied
parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1
Natural Gas Installation Code or CAN/CGA-B149.2 Propane Installation Code.
All pipe sealants must be an approved type and resistant to the actions of LPgases. Never use pipe sealant on
flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes
and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code,
ANSIZ223.1. Gas conversion kits are available from the factory. When ordering gas conversion kits, have the
model number, and the type of gas (natural or LP) from your grill.
TOTAL GAS CONSUMPTION OF THE GRILL WITH ALL BURNERS ON HI:
BGB30-BQR - 64,000 Btu/hr
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be
isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation
of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSIZ223.1. Installation in Canada must be in accordance with the Standard Canl-b149.1 and/or .2
(installation code for gas burning appliances and
equipment) and local codes.
NATURAL GAS HOOK UP: (THIS TYPE OF
CONNECTION SHOULD BE PERFORMED BY A
CERTIFIED OR LICENSED TECHNICIAN ONLY.)
Connection: 1/2" NPT male with 3/8" flare adapter.
Operating pressure: 4.0" W.C. Supply pressure: 5" to
14" water column. If in excess of 14" W.C., a step down
regulator is required. Check with your local gas utility
company or local codes for instructions on installing
gas supply lines. Be sure to check on type and size of
run, and how deep to bury the line. If the gas line is
too small, the grill will not function properly. Any joint
sealant used must be an approved type and be
resistive to the actions of LP gases.
TO HOOK-UP THE FITTINGS SUPPLIED
WITH THE GRILL:
Assemble as shown (Fig. 22). Use threading compound
on male threads only. Do not use threading
compound on the male end of the 1/2" NPT to 3/8 flare
adapter. Use a second pipe wrench to hold the grill inlet
o O
\ Botomofunt/
Coup,n9
Threading compound "/_
mustb .... istanttoLP gas _ £_/_ 12!02,:'NPTx
_ -_/ Nipple
\ _ __ Regulator
1/2"NPTxS.O"\ tS_/_// 4.o,,w.c.
CloseNipple _/_
_../ Adapter 1/2" NPT
j to 3/8"flare fitting
Installer
supplied
shut-off
__ _ Do not put threading
valve must be easily
accessible _
compound on these
threads
_lnstallation must conform with local
codes or with the National Fuel Gas Code
ANSI Z223.1 or the CAN/CGA-B149.2
Propane Installation Code
FIG. 22 Natural Gas
pipe to avoid shifting any internal gas lines of the grill. Ensure that the regulator arrow points in the direction of
gas flow towards the unit, away from the supply. Do not forget to place the installer-supplied gas valve in an
accessible location.
LP GAS HOOK UP (TYPE 1 OR QCCl REGULATOR):
Grills orificed for use with LP gas come equipped with a high capacity hose/regulator assembly for connection to
a standard 20 lb. LP cylinder (Type 1). The LP tank is not included.
16