Installation spacing for a recessed area or closet installation
All dimensions show recommended and minimum spacing
allowed.
n Additional spacing should be considered for ease of
installation and servicing.
n Additional clearances might be required for wall, door, floor,
moldings, dryer venting, and drain system.
n Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
n For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required for
vented models. Louvered doors with equivalent ventilation
openings are acceptable.
n Companion appliance spacing should also be considered.
Recommended installation clearances (dryer
only):
*Additional spacing recommended.
Minimum installation clearances (dryer only):
Front Sides Rear Top
Recessed NA 0" (0 mm) 0" (0 mm) 0" (0 mm)
Closet NA 0" (0 mm) 0" (0 mm) 0" (0 mm)
Under
Counter
NA 1" (25 mm) 0" (0 mm) 0" (0 mm)
0" (0 mm) rear spacing is allowed for straight-back venting only.
For steam models only, inlet hose must not be kinked.
Mobile Home – Additional installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety, Title
24, HUD Part 280) or the Standard for Mobile Homes, CAN/CSA-
Z240 MH.
Mobile home installations require:
n Metal exhaust system hardware, which is available for
purchase from your dealer.
n Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.
Electrical Requirements – U.S.A.
It is your responsibility:
n To contact a qualified electrical installer.
n To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/ NFPA
70 – latest edition and all local codes and ordinances. The
National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved in
remodeling after 1996, and all mobile home installations. A
copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02169–7471.
n To supply the required 3- or 4-wire, single-phase, 120/240 V,
60 Hz, AC-only electrical supply (or 3- or 4-wire, 120/208 V
electrical supply, if specified on the serial/rating plate) on a
separate 30 A circuit, fused on both sides of the line. Connect
to an individual branch circuit. Do not have a fuse in the neutral
or grounding circuit.
n Do not use an extension cord.
n If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
n This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground conductor must be
removed from the external ground connector (green screw),
and secured under the neutral terminal (center or white wire)
of the terminal block. When the neutral ground conductor is
secured under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor. The green ground wire of the 4-wire power cord
must be secured to the dryer cabinet with the green ground
screw
n If local codes do not permit the connection of a neutral ground
wire to the neutral wire, see “Optional 3-Wire Connection.”
n A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral conductor is prohibited for (1) new branch-circuit
installations after 1996, (2) mobile homes, (3) recreational
vehicles, and (4) areas where local codes prohibit grounding
through the neutral conductors.
If using a power supply cord:
Use a UL-listed power supply cord kit marked for use with clothes
dryers. The kit should contain:
n A UL-listed 30 A power supply cord, rated 120/240 V
minimum. The cord should be type SRD or SRDT and be at
least 4 ft. (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
n A UL-listed strain relief.