Installation Guidelines Part 1: Setup & Installation
Part 2: Setup & Installation
StreamLabs
®
Control
12V DC Power Adapter
3/4" and 1" come
with SharkBite
Disconnect Clips**
**1-1/4" Disconnect Clips can be purchased online
*Two spare included, only one per tting required for assembly
Gasket (4*)
Temporary Bypass Flow Tube
Close Button
Open Button
Wi-Fi Indicator LED
Wi-Fi Reset Button
9V Battery
Access Cover
(temporary
alternate
power only)
Power
Adapter
Plugin
NPT or SharkBite Unions (2)
Failure to comply with all aspects of these instructions may result in unsafe
performance.
All installations must comply with relevant State, Provincial and Local
Authority requirements.
Control can be installed vertically or horizontally.
If installing a Control with SharkBite
®
connections on copper pipe, use
appropriate grounding clamps and run a jumper wire across the unit.
Only use the provided StreamLabs DC Power Adapter.
The temporary bypass ow tube is for new construction or maintenance
applications of the Control.
Max pressure at max temperature: 200 psi at 105° F.
Control must be installed with correct ow direction as indicated on the
bottom of the unit.
1. Download the StreamLabs App.
2. Create an account or log in to an existing account.
3. Power your Control. The device should not be installed on pipe during initial
Wi-Fi pairing.
4. Follow the on-screen instructions in the app to setup and pair your device to
your wireless network.
5. Once Wi-Fi pairing is complete, unplug the Control, go to the installation
location and reference Part 2.
1. Locate your incoming cold water line.
The Control should be installed on the incoming water line aer a shut-o valve and a
pressure regulating valve. The Control is not meant to be used as the main shut-o valve to
the house. If you do not have a main shut-o valve or pressure regulating valve, install prior
to installing the Control.
Take note to install the Control prior to any pipe branches. Branches prior to the Control will
not be monitored or protected. At your installation location, you must have access to an
electrical outlet and a Wi-Fi signal. The Control comes with a DC power adapter with a 10
foot cord. Power adapters of additional lengths can be purchased from
StreamLabswater.com.
2.
Check your Wi-Fi strength at your installation location. If there is an inadequate
Wi-Fi signal:
a) Choose another location closer to your wireless router.
b) Relocate your wireless router closer to the installation.
c) Purchase a wireless extender to improve Wi-Fi coverage.
3. Shut o your incoming cold water line.
4. Drain your plumbing system.
5. If installing a Control with SharkBite connections refer to the pipe cut out table
below. If installing a Control with FNPT connections, thread your adapters (not
included) onto the unions and measure the cutout length.
Ball Valve
Cold Water to Home
PRV
Not MonitoredFlow Direction Monitored
Pipe Cut Out Table
6. Cut and remove pipe section. Ensure the pipe is cut clean, square, and is free
from any dirt or debris.
7. Install unions onto the cut sections of pipe. (If using SharkBite unions, refer to
the side 2 for How to Install a SharkBite Push-to-Connect Fitting)
8. Place a gasket into each union.
9. Insert the Control between the unions. Thread the unions by hand onto each
side of the Control. Tighten the union nuts with a wrench.
Make sure the device is installed with the directional arrow (found on the bottom of the
unit) pointing toward the direction of water ow.
10. Turn the water back on and check the installation.
11. Open a downstream faucet to ush air from your lines.
12. Plug the DC Power Adapter to an outlet and run the cable to power the
Control. The device will automatically reconnect to Wi-Fi and the Wi-Fi icon
will turn green.
13. Test the Control by opening and closing the valve using the touch panel on the
device.
14. Return to the StreamLabs App to complete setup.
Pipe Size SharkBite Pipe Cut Out Section
3/4 in. 8.5 in.
1 in. 10 in.
1-1/4 in. 10 in.
Copyright© 2019 all rights reserved by StreamLabs
®
• Terms of Service • Privacy Policy
Contact Us
website: StreamLabswater.com
support: support.StreamLabswater.com
email: support@StreamLabswater.com
phone: (770) 691–5524
rwc.com
streamlabswater.com/patents
Warning: This product can expose you to chemicals including lead which is known to the State of California to cause cancer
and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Certications
CE ICFCC NSF 61 NSF372
AUS/NZ 4268
Copyright© 2019 all rights reserved by StreamLabs
®
• Terms of Service • Privacy Policy
1. Check that ttings and pipe are clean, in good condition and are free from
damage and foreign objects. Also check that the pipe is free from scratches,
cuts, or gouges.
2. Cut the pipe so that the ends are square. Ensure that there are no burrs or
damage to the cut end.
3. Once the pipe end is cut square and clean, use the SharkBite Depth Deburr
Gauge (sold separately) and a permanent marker to mark the insert depth on
the outside of the pipe. (See chart to the right)
4. Insert the pipe through the release collar to rest against the grab ring.
5. Push the pipe rmly with a slight twisting action until it reaches the tube
stop, To ensure that the pipe is correctly inserted, check that the depth
mark is by the release collar.
Making a SharkBite
®
Connection
Pipe Size Insertion Depth
3/4 in. 1-1/8 in.
1 in. 1-3/8 in.
1-1/4 in. 1-7/8 in.
Insertion Depth Table
How should I go about selecting an installation
location for the Control?
The main water entry line may be located in a basement, utility closet, garage,
or crawlspace depending on which type of dwelling it is (a house, townhome
or apartment). The main water entry line should have a shut-o valve used to
stop the water supply to the home. (Note: this product is not intended to replace
the main shut-o valve in a dwelling.) The main water entry line is typically
near the water heater. It is the line that splits into the water heater and the cold
water for the building. The Control is compatible with 3/4", 1", and 1-1/4" pipe
diameters.
Install the Control on the main water line, before any branches to other
appliances, and aer the shuto valve and pressure reducing valve (PRV).
Installing on a pipe other than the main line will not allow you to see all water
usage in your home. The Control should only be installed indoors or in a covered,
enclosed area where it is safe from excessive moisture, temperature uctuations,
wind, and direct sunlight (such as a crawlspace). Note: If you don't have a PRV,
you may need to disable your pressure alerts. This device is not intended to serve
as the main shuto valve for your line. Do not install this product on a re
suppression system.
The Control requires varying lengths of pipe to be cut when using Sharkbite Push-
to-Connect (PTC) ttings.
We are not able to advise on cut lengths or space requirements if you are using
National Pipe Thread (NPT) ttings.
Please Note: Consider checking your Wi-Fi signal strength at this location
before installing the Control. The Control requires a 2.4ghz Wi-Fi connection
for operation. Try opening a browser page on your phone from this location to
ensure you receive a signal. The chosen install location must also be in range of
a standard wall outlet. The included power supply can reach an outlet a linear
distance of 10 feet away from the install spot. 25-foot and 50-foot extension
cords are available for purchase on
www.StreamLabsWater.com.
For more information about the StreamLabs Control, please visit our website
at www.StreamLabsWater.com.
The Wi-Fi icon will indicate dierent connectivity status. See below for a guide on
how to interpret the Wi-Fi LED.
Amber, single-blinking pattern: The Control is in pairing mode and is waiting for
a smart phone or tablet to connect to it during the Wi-Fi setup process.
Amber, solid: A smart phone or tablet is currently connected to the Control.
The Control will play a short beeping tune when this connection is successfully
established.
Green, double-blinking pattern: The Control is attempting to pair to the Wi-Fi
network with the password that was given to it.
Green, triple-blinking pattern: The Control has connected to the Wi-Fi network
and is now attempting to reach the StreamLabs servers.
Green, single-blink once every 3-4 seconds: The Control has established a
connection to the StreamLabs servers via Wi-Fi and is now online.
If there is an error at any point during the connection or Wi-Fi setup process, the
Wi-Fi LED will revert to Amber and the error message will be displayed on the
screen in the StreamLabs app.
Federal Communications Commission Regulations
FCC & IC Disclosure
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20cm between the radiator and any part of your body.
Additional Information, Warnings and Certifications Industry Canada Regulations
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not
more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
This equipment complies with the ICES RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20cm between the radiator and any part of your body.
Cet équipement est conforme aux limites d’exposition aux radiations ICES définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé à une
distance minimale de 20 cm entre le radiateur et une partie de votre corps
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2)
This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Antenna Information
NOTE: The UFCV-1000 Module bearing FCC ID: 2AHFE-UFCV1000 and IC: 21143-UFCV1000 has been approved by the FCC and ISED to operate with the antenna types listed
below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater
than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Inverted F PCB antenna, +0.97dBi peak
Le présent émetteur radio RM-10002705, FCC ID: USKRM-10002705, IC: 11898A-10002705 a été approuvé par FCC y ISED pour fonctionner avec les types d'antenne énumérés
ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur
au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
Antenne F inversée pour circuit imprimé, pic de 0,97 dBi
Wi-Fi Troubleshooting
In what direction and orientation should I
install the Control?
The Control must be installed such that the direction of water ow in the pipe
matches the direction of the arrow on the bottom of the unit. If you're looking at
the top of the StreamLabs Control unit such that the words "open" and "close"
are upright and read le to right, the water in the pipe should ow from the le of
the unit to the right of the unit.
The Control can be installed either horizontally or vertically as long as it is
installed in the correct orientation with respect to ow direction as shown above.