INTRODUCTION
The Light incorporates a PIR (Passive Infra Red) sensing device
which continuously scans a preset operating zone and immediately
switches the light on when it detects movement in that area. This
means that whenever movement is detected within the range of the
sensor the light will switch on automatically to illuminate pathways,
steps, patios, porches, or whatever area you have selected to light
for reasons of safety, convenience or security.
While there is movement within range of the unit the light will remain
on.
The light incorporates a camera which continuously scans a preset
operating zone and record the video when it detects movement in
that area. .
WHILE TO FIT YOUR LIGHT
To achieve best results, we suggest you account the following
points:
Ideally the Light should be mounted 1.8 to 2.5 meters (6 to 8ft)
above the area to be scanned
To avoid damage to unit-do not aim the sensor towards the sun.
To avoid nuisance triggering, the sensor should be directed
away from heat sources such as barbecues, Air-conditioners,
other outside lighting, moving cars and flue vents.
To avoid nuisance triggering, keeping away from the area of
strong electromagnetic disturbance.
Do not aim towards reflective surfaces such as smooth white
walls, swimming pools, etc. The Security light scanning
specifications (Max. 15 meters at 180°) may vary slightly
depending on the mounting height and location. The detection
range of the unit may also alter with temperature change.
Before selecting a place to install your light you should note that
movement across the scan area is more effective than
movement directly toward or away from the sensor. (refer
Figure). If movement is made walking directly towards or away
from the sensor and not across, the apparent detection range
will be substantially reduced.
FITTING THE UNIT
Installation by a licensed electrician and according to IEC wiring
Regulation.
Before commencing any electrical work, ensure mains supply
cables are isolated by switching off and removing the relevant
fuse.
1. Mounting the mounting support onto the Junction box
2. Connect the main cable to the terminal
3. Mounting the mounting panel onto the mounting support
4. Mounting the main light onto the mounting panel.
5. Switch the main power on.
IMPORTANT:
1. Never attempt to remove the lens cover as this will damage the
sensor and render all guarantees invalid.
2. Before touching the light, please switch off first and then let it
cool
UNDERSTANDING THE CONTROLS (referring to
the Figure)
ADJUSTING THE ON TIME: The length of time that remains
switched on after activation can be adjusted between
TEST,1min,5min,20min .
Note:
1. Once the light has been triggered by the PIR sensor any
subsequent detection will start the timed period again from the
beginning.
2. TEST, the light will turn on about 5s whether day or night
3. 1min,5min,20min:The light only turn on at night.
ADJUSTING THE DURATION SENS: The sensitivity means the
Maximum distance which PIR Sensor can be triggered by
movement body.
ADJUSTING THE Brightness LEVEL: The brightness of the light
can be adjusted between high and low
ADJUSTING THE Dual Brite: The Dual brightness of the light can
be adjusted between OFF ,6h ,Dusk to Dawn.
OFF: No dual brightness
6h: The light will turn on at low brightness at night, then off after 6
hours or going to day, in this time, When the signal is sensed, the
lights will turn on high brightness.
Dusk to Dawn: The light will turn on at low brightness all the night,,
in this time, When the signal is sensed, the lights will turn on high
brightness.
TECHNICAL DETAILS :
Voltage:108-132 VAC ~ 60Hz
Wattage: 20W LED
Lumen: 2200LM
Color temperature:4000K
Detection range: 180º and Max. 15 meters
Duration time: TEST,1min,5min,20min
Weatherproof: IP44
ProtectionClass
Suitable for indoor and outdoor use
CompanyAUROLITE AUTOTECH
GUANGDONG LTD
AddressNo. 1 Jinsheng 1 Road, Hualong
Town, Panyu District, Guangzhou, China
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Warning: Changes or modtifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference
that may cause undesired operation of the device.
FCC Responsible Party Name:Globe Electric Company Inc.
Address: 150 Av. Oneida, Pointe-Claire, QC H9R 1A8 Canada
Telephone Number: (514) 694-0444
CAN ICES-005 (B)/NMB-005 (B)
RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set
forth for anuncontrolled environment. This equipment should be inst
alled and operated with minimum distance 20cm between the
radiator & your body.
This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil contient des émetteurs / récepteurs exemptés de
licence conformes aux RSS (RSS)d'Innovation, Sciences et
Développement économique Canada. Le fonctionnement est
soumis aux deux conditions suivantes :
(1) Cet appareil ne doit pas causer d'interférences.
(2) Cet appareil doit accepter toutes les interférences, y compris
celles susceptibles de provoquer un fonctionnement indésirable de
l'appareil.
avertissements radio pour les appareils portables :
L' équipement a été évalué et satisfait aux exigences générales
d'exposition par radiofréquence. L'appareil peut être utilisé sans
restriction dans des conditions d'exposition portables.
  • Page 1 1
  • Page 2 2

Globe Electric 17000214 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues