Globe Electric 17000213 Manuel utilisateur

Taper
Manuel utilisateur
Outdoor Fixed Security Light with remote
sensor
MODEL:17000213
INTRODUCTION
It contains a light and a sensor.
The sensor incorporates a PIR (Passive Infra Red) sensing device
which continuously scans a preset operating zone and immediately
transmit a signal to the light to switches the light on when it detects
movement in that area. This means that whenever movement is
detected within the range of the sensor the light will switch on
automatically to illuminate pathways, steps, patios, porches, or
whatever area you have selected to light for reasons of safety,
convenience or security.
While there is movement within range of the unit the light will remain
on.
WHILE TO FIT YOUR LIGHT
To achieve best results, we suggest you account the following
points:
Ideally the Light should be mounted 1.8 to 2.5 meters (6 to 8ft)
above the area to be scanned
To avoid damage to unit-do not aim the sensor towards the sun.
To avoid nuisance triggering, the sensor should be directed
away from heat sources such as barbecues, Air-conditioners,
other outside lighting, moving cars and flue vents.
To avoid nuisance triggering, keeping away from the area of
strong electromagnetic disturbance.
Do not aim towards reflective surfaces such as smooth white
walls, swimming pools, etc. The sensor scanning specifications
(Max. 15 meters at 240°) may vary slightly depending on the
mounting height and location. The detection range of the unit
may also alter with temperature change. Before selecting a
place to install your sensor you should note that movement
across the scan area is more effective than movement directly
toward or away from the sensor. (refer Figure). If movement is
made walking directly towards or away from the sensor and not
across, the apparent detection range will be substantially
reduced.
FITTING THE UNIT
Installation by a licensed electrician and according to IEC wiring
Regulation.
Before commencing any
electrical work, ensure mains
supply cables are isolated by
switching off and removing the
relevant fuse.
Mounting the Light:
1. Mounting the mounting support
onto the Junction box
2. Connect the main cable to the
terminal
3. Mounting the mounting panel
onto the mounting support
4. Mounting the main light onto the
mounting panel.
5. Switch the main power on.
Mounting the Sensor:
1. emove the back cover
2. Unscrew the battery cover
screw
3. Remove the battery cover
4. Instilling two AA batteries into
the battery box. Re-fit the
battery cover onto the sensor
5. Use the back cover to mark
the position of screw holes
onto mounting surface. Drill
the wall to depth of about 60
mm and fit the plastic plugs,
and then fix the Cover to the
mounting surface with rightly
screws. Be careful to avoid
drilling or screwing into
concealed electrical wiring.
6. Mounting the back cover
onto the wall
7. Mounting the sensor onto the
back cover.
IMPORTANT:
1. Never attempt to remove the
lens cover as this will damage
the sensor and render all
guarantees invalid.
2. Before touching the light, please switch off first and then let it
cool
UNDERSTANDING THE CONTROLS (referring to
the Figure)
ADJUSTING THE ON TIME: The length of time that remains
switched on after activation can be adjusted between
TEST,1min,5min,20min .
Note:
1. Once the light has been triggered by the PIR sensor any
subsequent detection will start the timed period again from the
beginning.
2. TEST, the light will turn on about 5s whether day or night
3. 1min,5min,20min:The light only turn on at night.
ADJUSTING THE DURATION SENS: The sensitivity means the
Maximum distance which PIR Sensor can be triggered by
movement body.
Distribution network method:
Long press the switch, the indicator light will flash 5 times, and then
release. The indicator light will flash every 1 second. At this time, the
sensor enters the distribution mode, and the lights that have not
been connected to the network will be powered on. The lights will
remain on for 3 minutes when not distributed to the network, and will
turn off after being distributed to the network. Press the switch again
for 1 second, and the sensor will exit the distribution mode
Cleaning network method: (Note: Even sensors that have not
been connected to this light can be cleaned and re connected to this
light)
Turn off the light that needs to be cleaned, press the switch, and the
indicator light will flash 10 times before releasing. The indicator light
will remain on, and the sensor will enter the cleaning mode. Then,
turn on the light that needs to be cleaned, and enter the cleaning
mode. The successful cleaning light will flash 5 times every 1
second, and then enter the constant light mode for 3 minutes; Press
the switch again for 1 second, and the sensor will exit the cleaning
mode. If it is necessary to distribute the network for this lamp, it
needs to be distributed according to the distribution network method
within 3 minutes.
TECHNICAL DETAILS :
LIGHT:
Voltage:108-132 VAC ~ 60Hz
Wattage: 20W LED
Lumen: 2200LM
Color temperature:4000K
Weatherproof: IP44
ProtectionClass
SENSOR:
Voltage: 2 AA 1.5V battery
Detection range: 240º and Max. 15 meters
Duration time: TEST,1min,5min,20min
Weatherproof: IP44
ProtectionClass
Suitable for indoor and outdoor use
CompanyAUROLITE AUTOTECH
GUANGDONG LTD
AddressNo. 1 Jinsheng 1 Road, Hualong
Town, Panyu District, Guangzhou, China
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Warning: Changes or modtifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference
that may cause undesired operation of the device.
RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set
forth for anuncontrolled environment. This equipment should be inst
alled and operated with minimum distance 20cm between the
radiator & your body.
This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil contient des émetteurs / récepteurs exemptés de
licence conformes aux RSS (RSS)d'Innovation, Sciences et
Développement économique Canada. Le fonctionnement est
soumis aux deux conditions suivantes :
(1) Cet appareil ne doit pas causer d'interférences.
(2) Cet appareil doit accepter toutes les interférences, y compris
celles susceptibles de provoquer un fonctionnement indésirable de
l'appareil.
avertissements radio pour les appareils portables :
L' équipement a été évalué et satisfait aux exigences générales
d'exposition par radiofréquence. L'appareil peut être utilisé sans
restriction dans des conditions d'exposition portables.
FCC Responsible Party Name:Globe Electric Company Inc.
Address: 150 Av. Oneida, Pointe-Claire, QC H9R 1A8 Canada
Telephone Number: (514) 694-0444
CAN ICES-005 (B)/NMB-005 (B)