red lion RAM-6021 Guide de démarrage rapide

Taper
Guide de démarrage rapide
CONNECT. MONITOR. CONTROL. © 2014 - 2017 Red Lion Controls. All Rights Reserved 1
QUICK START GUIDE
RAM-6021 WIRED ROUTER
LP1043-A
UNPACKINGINSTRUCTIONS
1. Unpack the Red Lion unit and verify the following compo-
nents are enclosed for the RAM-6021 Router: RAM-6021 &
this quick start guide.
2. There are 2 methods to provide power to the router:
4-pin screw terminal
Side mounted 2.5mm barrel connector
The router requires a power source between 8 and 30 VDC
to operate:
3. Connect to the WAN or LAN port for network connectivity.
ACCESSINGTHEWEBUSERINTERFACEUSINGAUTONET
1. Connect the RAM-6021 router to an existing network.
a. Connect an Ethernet cable between the router and your
local corporate LAN or directly to your PC/Laptop.
b. Verify the green LED on the Ethernet port is lit.
2. RAM-6021 will obtain its IP address via DHCP if a DHCP
server is present, if not the Ethernet interface will set a static
IP and enable a DHCP server on the interface. If your PC is
connected directly to the Red Lion router it will obtain a local
IP address from the router.
3. Access Web User Interface
Open a web browser and navigate to http://ram-<Last 6 of
Ethernet MAC Address>:
Example: http://ram-6d3f11.local/
ACCESSINGTHEWEBUSERINTERFACE(TRADITIONALMETHOD)
1. Connect the PC to the RAM-6021 router.
a. Connect an Ethernet cable between the local PC and any
available Ethernet port.
2. Setup PC IP Address.
PC to Ethernet Interfaces
Select “Use the following IP address” and fill in the blank
fields with the information below:
3. Access Web User Interface
Open a web browser and enter the following in the address
bar:
WAN/ETH0: http://192.168.0.1:10000/
LAN/ETH1: http://192.168.1.1:10000/
LOGININSTRUCTIONS
User Name: admin (lowercase letters)
Password: last six digits of the unit’s serial number
Upon successfully logging in, the web UI will launch.
Note: For security purposes, it is recommended that the
admin password be changed according to your internal poli-
cies.
To change password, go to: Admin
Access Settings.
If you have any problems getting connected, please refer to the
Red Lion Software Manual located at::
www.redlion.net/sixnet_documentation.
Web UI:
You are now connected to the web interface. If you should
see anything other than the screen shown above, please
refer to the RAM-6021 User Manual, located on our website:
www.redlion.net.
For more information to set up Modbus features, please refer
to the RAM-6021 User Manual.
LABEL DESCRIPTION
GND Ground
PWR+ Power 8 to 30 VDC (12 or 24 VDC
nominal)
IN Digital and analog input
OUT Digital output
WAN/ETH0 LAN/ETH1
IP Address 192.168.0.2 192.168.1.2
Subnet Mask 255.255.255.0 255.255.255.0
Default Gateway 192.168.0.1 192.168.1.1
Preferred DNS 192.168.0.1 192.168.1.1
CONNECT. MONITOR. CONTROL. © 2014 - 2017 Red Lion Controls. All Rights Reserved 2
Quick Start Guide
HARDWARESTATUSLEDS
REDLIONCONTROLSTECHNICALSUPPORT
If you have followed all of the instructions up to this point, are
satisfied that you are not having an authentication problem
and your unit is still not communicating, then it it is time to
contact Red Lion Technical Support at [email protected]
or 1-877-432-9908.
INSTALLATIONANDHAZARDOUSAREAWARNINGS
All power, input and output I/O wiring must be in accordance
with Class I, Division 2 wiring methods are in accordance
with the authority having jurisdiction. This equipment is suit-
able for Use in Class 1, Division 2, Groups A, B, C and D or
Non-Hazardous Locations Only.
WARNING - EXPLOSION HAZARD - DO NOT DISCON-
NECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-
HAZARDOUS.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2.
WARNING - EXPLOSION HAZARD - BATTERIES MUST
ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-
HAZARDOUS.
WARNING - EXPOSURE TO SOME CHEMICALS MAY
DEGRADE THE SEALING PROPERTIES OF MATERIALS
USED IN THE RELAYS.
WARNING – POWER JACK CONNECTOR IS NOT TO BE
USED IN HAZARDOUS LOCATIONS.
AEVERTISSEMENTSPOURINSTALLATIONETENDROITSDANGEREUX
Tout pouvoir, le câblage d'entrée et de sortie (I/O) doivent
être conformes aux méthodes de câblage de Classe I, Divi-
sion 2 et conformément à l'autorité compétente. Cet équipe-
ment est adapté pour une utilisation en Classe1, Division 2,
Groupes A, B, C et D ou endroits non-dangereux seulement
AVERTISSEMENT - RISQUE D'AVERTISSEMENT - NE
DÉBRANCHEZ PAS L'ÉQUIPEMENT PENDANT QUE LE
CIRCUIT EST DIRECT OU À MOINS QUE L'ENVIRONNE-
MENT SOIT CONNU POUR ÊTRE NON-DANGEREUX.
AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTI-
TUTION DE TOUT COMPOSANT PEUT NUIRE À LA CON-
FORMITÉ DE CLASSE I, DIVISION 2.
AVERTISSEMENT - RISQUE D'EXPLOSION - LES BAT-
TERIES DOIVENT SEULEMENT ÊTRE REMPLACÉES
DANS UNE ZONE RECONNUE COMME ÉTANT NON-
DANGEREUSE.
AVERTISSEMENT - L'EXPOSITION À CERTAINS PRO-
DUITS CHIMIQUES PEUT DÉGRADER LES PROPRIÉTÉS
D'ÉTANCHÉITÉ DES MATÉRIAUX UTILISÉS DANS LES
RELAIS ÉTANCHE PÉRIPHÉRIQUE.
AVERTISSEMENT – CONNECTEUR JACK D'ALIMENTA-
TION NE DOIT PAS ÊTRE UTILISÉ DANS DES ENDROITS
DANGEREUX.
LED State Description
Power ON Power is applied to the router
W View section 1.1.7 in Hardware
Guide
RS232 ON Link established with serial device
but no data activity
FLASH Data transmitted/received with
attached serial device
Ethernet ON Link established with Ethernet
device
  • Page 1 1
  • Page 2 2

red lion RAM-6021 Guide de démarrage rapide

Taper
Guide de démarrage rapide

dans d''autres langues