GE RAK180W1 Le manuel du propriétaire

Catégorie
Thermostats
Taper
Le manuel du propriétaire
THERMOSTAT
Wireless Thermostat with Occupancy Sensor
OWNER’S MANUAL &
INSTALLATION INSTRUCTIONS
RAK180W1
49-5000416 Rev. 1 07-19 GEA
F
2 49-5000416 Rev. 1
THANK YOU FOR MAKING GE APPLIANCES A
PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is
your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and
design that goes into every GE Appliances product,
and we think you will too.
49-5000416 Rev. 1 3
Table of Contents
Safety Information ............................................................................................................ 4
Before You Begin .................................................................................................................5
Thermostat Installation .................................................................................................... 7
Installing the Wireless Control card ........................................................................................7
Wireless Installation ...............................................................................................................10
Wired Installation ....................................................................................................................10
Thermostat Configuration ............................................................................................11
Setting the clock .....................................................................................................................12
Entering the room number ....................................................................................................13
Configuring the Equipment Settings - Compressor Type ....................................................14
Configuring the Equipment Settings - Electric Heat ............................................................15
Configuring the Equipment Settings - Reversing Valve ......................................................16
Configuring the Energy Saving Settings...............................................................................17
Custom Energy Savings Settings .............................................................................. 19
Using the Thermostat Settings Screens ...............................................................................20
01 – FAN CONTROL MODE ................................................................................................21
02 – 1ST STAGE DIFFERENTIAL - HEAT .........................................................................22
03 – 2ND STAGE DIFFERENTIAL - HEAT ........................................................................23
04 – 1ST STAGE DIFFERENTIAL - COOL ........................................................................24
05 – INCIDENTAL OCCUPANCY THRESHOLD ...............................................................25
06 – NIGHT OCCUPANCY THRESHOLD ..........................................................................26
07 – FORCED 2ND STAGE HEATING ...............................................................................27
08 – NIGHT OCCUPANCY START .....................................................................................28
09 – NIGHT OCCUPANCY END .........................................................................................29
10 – TEMPERATURE RECOVERY TIME ..........................................................................30
11 – RECOVERY TEMPERATURE - HEAT .......................................................................31
12 – TEMPERATURE SETBACK DELAY - HEAT .............................................................32
13 – MINIMUM SETBACK TEMPERATURE ......................................................................33
14 – TEMPERATURE SETBACK DELAY - COOL ............................................................34
15 – MAXIMUM SETBACK TEMPERATURE.....................................................................35
16 – RECOVERY TEMPERATURE - COOL ......................................................................36
17 – MINIMUM SET POINT .................................................................................................37
18 – MAXIMUM SET POINT ................................................................................................38
19 – TEMPERATURE CONTROL MODE ...........................................................................39
20 – AUTO CHANGEOVER SET POINT OFFSET
(DEAD BAND) ...............................................................................................................40
21 – SETBACK SET POINTS / AUTO-RESTORE .............................................................41
22 – AUTOMATIC HUMIDITY CONTROL† ........................................................................42
23 – TEMPERATURE CALIBRATION.................................................................................43
Thermostat Maintenance .............................................................................................44
Troubleshooting ................................................................................................................45
Appendix 1 - Energy Saving Presets ......................................................................48
Technical Specifications ..............................................................................................49
Limited Warranty ..............................................................................................................50
4 49-5000416 Rev. 1
Specifications.
WARNING
FIRE AND SHOCK HAZARD
Always turn off power at the main power supply
before installing, cleaning or removing the
thermostat. Failure to do so could result in
electrical shock hazard.
Do not use on voltages over 30 VAC. Higher
voltages will damage the thermostat and could cause
shock or fire hazard.
NOTICE
All wiring must conform to local and national
electrical and building codes.
Use this thermostat only as described in this manual.
Electrical rating: 24 VAC (18–30 VAC)
1 amp maximum per terminal
4 amp maximum total load
Operating temperature range: 40°F–99°F (4°C–37°C)
System Configurations:
* 1 stage cool, 2 stage heat (heat pump/resistance heat)
1 stage cool, 1 stage heat (resistance heat)
Terminations: *R, C, W, Y, GH, GL, B for 2-stage heat
R, C, W, Y, GH, GL, for 1-stage heat
Wiring:
Maximum wiring length is 66ft (20 meters) for
AWG18
Maximum wiring length is 60ft (18 meters) for
AWG20
*Default setting
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
49-5000416 Rev. 1 5
Before You Begin
Determine the appropriate installation location for the
thermostat
The thermostat should face the bed area of the
room.
The thermostat must not be installed near or on
metal structures or surfaces including metal air
ducting that may be in the wall.
0HWDOVWUXFWXUHVDQGVXUIDFHVVLJQL¿FDQWO\
reduce the range of the wireless signal.
A. Refer to the Zoneline Owner’s Manual to change
the AUX setting to 6A (class 2 mode). The unit will
display “use wall thermostat” when finished.
B. Zoneline output is 24VAC. Be sure the jumper on the
wireless control card is on the AC position – jumper
is connecting “R” and “C” (common) pins. This is the
default position.
Other Zoneline Auxilary Control Settings for use with
*DBM & *EBM Models
Mode E: Enables Zoneline Makeup air vent door control
EDVHGRQRFFXSDQF\GHIDXOWLVRႇDQGPRGHPXVWEH
turned on to utilize this feature.
Refer to the Zonelines Owner’s Manual for instructions
on how to change this AUX setting/mode.
6 49-5000416 Rev. 1
NETWORK INSTALLATION ONLY
NOTE: This section is not required unless the thermostats are
networked
Pairing the Thermostat and the Control Card:
In case of Network Installation with online management, the
thermostat and the Control Card must be paired with a Network
Programmer specific to the property before the installation.
Note: Thermostat and Control Card are factory paired.
The thermostat and control card must not be powered during the
pairing procedure - remove batteries from the thermostat and unplug
the control card from the HVAC unit during the pairing procedure.
• Plug one programmer connector into the thermostat;
Plug the other programmer connector into the control card.
Push the black button on the programmer.
The red light on the programmer should turn on and remain
steadily lit.
If the red light on the programmer is blinking or is not steadily
lit, unplug the programmer from the thermostat and the control
card and repeat the steps above.
Unplug the programmer from the thermostat and the control card.
Thermostat
Network
Programmer
Programmer
Connector
Control
Card
49-5000416 Rev. 1 7
Thermostat Installation
Installing the Wireless Control Card
Power off the Zoneline
Insert the Control Card wiring harness into the thermostat
connection port on the front of the Zoneline control box cover.
For Makeup Air Models (*DBM and *EBM), insert the small
connector into the mating CDC Connection port next to the
thermostat port. (See Drawing 1)
NOTE: If not a Makeup Air Model, DO NOT plug in the CDC/
occupancy connection.
AC input
CDC /
Occupancy
Connection
Remote
Thermostat
Connection
Red Aux Set
Button
Drawing 1
8 49-5000416 Rev. 1
Thermostat Installation
Installing the Wireless Control Card (cont.)
Using the supplied double sided tape, attach the control card
to the Zoneline control box cover. (See Drawing 2)Mount the
control card inside of the hvac unit.
The wireless control card antenna must not be touching any metal
components of the hvac unit.
The wireless control card antenna must face the thermostat on the
wall and be oriented so that any metal parts of the Zoneline do not
obstruct the wireless communication to the thermostat and, in case of
a network installation, to other wireless control cards and the server.
The wireless control card must not be placed in the Zoneline
condensation pan and must be mounted so it cannot fall into the
condensation pan.
For wired applications, join the common and 24VAC wires with
any code-approved low voltage field supplied connection method.
CDC/
Occupancy
Remote
Thermostat
Connection
Control
Card
Drawing 2
49-5000416 Rev. 1 9
Thermostat Installation
Wire Color Terminal Letter Terminal Connection
Black C Common
Red R 24V
Yellow Y Compressor
White W Heat
Orange O or B Reversing Valve
Green GH Fan High
Purple GL Fan Low
Brown AUX Occupancy
NOTE: If the PTAC unit has only one (1) fan speed,
connect both fan control wires – Green and Purple –
to the fan terminal (G).
Wiring Table 24V AC
10 49-5000416 Rev. 1
Thermostat Installation
Wireless Installation
GH OB W R Y C
AUX
GL
F
Mounting the thermostat to the wall
Remove the thermostat cover;
Use the supplied wall anchors and mounting screws to
secure the thermostat to the wall;
Insert two (2) AA-cell batteries (not supplied) into the
thermostat battery compartment;
Follow the “Thermostat Configuration” instructions
starting on page 11.
Replace the thermostat cover and screw in the locking
screw.
Wired Installation
GH OB W R Y C
AUX
GL
R C
F
Mounting the thermostat to the wall
Connect R & C from HVAC unit to the corresponding
wires on the harness by splicing 24VAC and common
wires from the thermostat into the 24VAC and common
wires to the zoneline.
Remove the thermostat cover;
Use the supplied wall anchors and mounting screws to
secure the thermostat to the wall;
Follow the “Thermostat Configuration” instructions
starting on page 11.
Replace the thermostat cover and screw in the locking
screw.
49-5000416 Rev. 1 11
Thermostat Configuration
Once the thermostat is powered, thermostat configuration
settings will appear on the thermostat screen.
In order to properly operate the HVAC unit:
Set the thermostat clock
Enter the room number
Configure the equipment settings
Select Energy Savings Preset (Zoneline custom settings
are the default).
The thermostat configuration screens have a 30-second
time-out. If no action is taken within thirty (30) seconds, the
thermostat will exit configuration settings.
NOTE: You can
access Thermostat
Configuration settings at
any time by pressing the
“Configuration” button.
NOTE: If the thermostat is connected to a network, the
settings configured online will be applied.
12 49-5000416 Rev. 1
Thermostat Configuration
Setting the thermostat clock
Set the thermostat clock to current time in 24h (Military Time)
format.
Use the “Up” and “Down” buttons to set the hours
Press the “Fan” button to advance to the minutes setting
Use the “Up” an “Down” buttons to set the minutes
Press the “F/C” button to advance to the next menu
Setting the clock correctly is crucial for proper operation of
the thermostat.
NOTE:
The thermostat clock will need to be reset each time
the batteries are replaced.
Hours
Minutes
49-5000416 Rev. 1 13
Thermostat Configuration
Entering the room number
Enter the room number by changing the digits on the screen.
Leading zeros “0” preceding other digits will be ignored, i.e.
Room number “123” should be entered as “00123”.
Use the “Up” and “Down” buttons to change the digit;
Press the “Fan” button to advance to the next digit;
Press the “F/C” button to advance to the next menu;
Entering the room number correctly is crucial for proper
operation of networked systems.
14 49-5000416 Rev. 1
Thermostat Configuration
Configuring the Equipment Settings - Compressor Type
Use the “Up” and “Down” buttons to change the compressor
type by changing the first digit
0 - No Compressor
1* - Heat pump
2 - Air Conditioner
Press the “Fan” button to advance to the next setting;
* Indicates default setting
NOTE:
If the Zoneline is an AZ45 model, change the
compressor type to a 2.
Compressor Type
49-5000416 Rev. 1 15
Thermostat Configuration
Configuring the Equipment Settings - Electric Heat
Use the “Up” and “Down” buttons to change the Electric Heat
setting by changing the second digit;
0 - No Electric Heat- All Zonelines have Electric heat -
Do not select this option.
1* - Electric Heat
Press the “Fan” button to advance to the next setting;
* Indicates default setting
Electric Heat
16 49-5000416 Rev. 1
Thermostat Configuration
Configuring the Equipment Settings - Reversing Valve
Use the “Up” and “Down” buttons to change the reversing
valve type by changing the first digit
0 - OB contact is energized to cool
1* - OB contact is energized to heat (default operation for
Zoneline heat pump models)
Refer to the HVAC unit documentation to determine the
correct OB VALVE setting.
If incorrect OB VALVE Setting is selected, the HVAC
unit will turn on the heating when air conditioning is
requested and turn on the air conditioning when heating is
requested.
Press the “F/C” button to advance to the next menu
Press the “Fan” button to advance to toggle to equipment
settings.
* Indicates default setting
NOTE: Zonelines OB is energized in heating mode.
Reversing Heat
49-5000416 Rev. 1 17
Thermostat Configuration
Configuring the Energy Saving Settings
Use the “Up” and “Down” buttons to select the Energy Saving
preset:
E-C*: Custom Energy Savings
Refer to the APPENDIX 1 on page 48 for Energy Saving
Preset details.
For details on changing the custom settings, refer to the
“Custom Energy Savings Settings” section on page 19.
E-0: Energy Savings Off - No Temperature Setback;
E-1: Lowest Energy Savings;
E-2: Lower Energy Savings;
E-3: Standard Energy Savings;
E-4: Higher Energy Savings;
E-5: Highest Energy Savings;
Press the “Power” button to save the Thermostat
Configuration and start using the thermostat.
* Indicates default setting
18 49-5000416 Rev. 1
Thermostat Configuration
Testing the thermostat
Following the thermostat configuration, test if the thermostat
is controlling the Zoneline unit.
Press the “Power” button to turn the thermostat ON;
Press the “Down” button to change the temperature set
point below the current room temperature to confirm that
the thermostat initiates air conditioning.
Press the “Up” button to change the temperature set point
above the current room temperature to confirm that the
thermostat initiates heating.
Change the fan speed by touching the “Fan” button to test if
the thermostat is controlling the fan speed.
49-5000416 Rev. 1 19
Custom Energy Savings Settings
This thermostat comes preprogrammed to use a custom
energy setting. To change any of these presets, follow the
instructions below.
Accessing the Thermostat Settings
With the thermostat turned on, press and hold the
“Configuration” button until the first thermostat settings screen
appears. The thermostat must be turned on to access the
thermostat settings.
³&RQ¿JXUDWLRQ´EXWWRQ
NOTE: If the thermostat is connected to a network, the
settings configured online will be applied.
Use the “Up” and “Down” buttons to change the setting;
Press the “F/C” button to advance to the next setting;
Press the “Fan” button to return to the previous setting;
Press the “Power” button to save and exit thermostat
settings.
20 49-5000416 Rev. 1
Custom Energy Savings Settings
Using the Thermostat Settings Screens
Use the “Up” and “Down” buttons to change the setting.
Press the “F/C” button to advance to the next setting.
Press the “Fan” button to return to the previous setting.
Press the “Power” button to save and exit thermostat
settings.
The above is a representation of how to read the
digits on the thermostat screen.
Setting Value
Screen Number
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150

GE RAK180W1 Le manuel du propriétaire

Catégorie
Thermostats
Taper
Le manuel du propriétaire

dans d''autres langues