Dirt Devil
®
Built - In Central Vacuum Systems
OPERATING INSTRUCTIONS
Dirt Devil
®
Filtered Cyclonic
MODELS:
299e, 599e & 799e
General Information
Do Not Store Objects on top of the
power unit. This will block the motor
cooling ventilation. Restricting the
cooling airflow may shorten the
motor life.
The central vacuum is designed to vacuum
ordinary household dirt and dust. The
system is designed for dry pickup. A Wetvac
accessory is needed if the system will be
used for liquid pickup.
The central vacuum system is a network
of inlet valves, 2” PVC tubing, and
low voltage wiring installed in the walls
of your home. To operate the system,
simply plug the hose into an inlet valve,
attach the cleaning tool to the curved
hose end and begin vacuuming. The dirt
is transported through the in-wall tube
system back to the dirt canister (located
on the power unit).
Caution: Do not allow the motor
to remain turned on, unless a hose is
connected or an inlet valve is open. If
air is not permitted to pass through the
fan blades, damage may occur to the
motor.
Operating Instructions
Using the Central Vacuum System is easy.
Simply raise the inlet valve lid, insert the
hose end and attach the desired cleaning tool
to the
hose wand. The Power Unit is
activated when the hose is inserted
into the valve.
Emptying the Dirt
Canister & Replacing
The Filter Cartridge
The dirt canister – where the
vacuumed dirt is deposited – is the
removable lower portion of the power
unit. The canister needs to be removed
and emptied when it is 1/2 - 2/3 full.
The filter cartridge should be replaced
once a year.
When the dirt canister is removed the
Cyclonic Cone will be visible. The cone
is designed to stay attached to the body
of the power unit when the dirt canister
is removed. The cone is removable to
allow access to the replaceable pleated
filter. To replace the cone, follow the
steps listed under replacing the filter.
Follow these steps to empty the dirt
canister (refer to Illustration #1)
Make sure the Power Unit is OFF.
1) Disengage the canister latches located
on opposite sides of the power unit.
2) Remove the dirt canister.
3) Dispose of canister contents in trash
receptacle.
4) Raise the empty dirt canister to the
proper location under the power unit
and engage the latches.
5) Be certain the dirt canister and
the cyclonic cone seal are “seated”
properly to the body of the unit.
Follow these steps to replace the filter
cartridge
(refer to Illustration #2)
Make sure the Power Unit is OFF.
1) Unlatch and remove the Dirt
Canister.
2) Remove the cyclonic cone by pulling
down on it. Place cone in dirt
canister.
3) Remove the pleated filter by turning
the filter latch 90° (counterclockwise) to
disengage the filter. (The filter latch is
located at the bottom of the pleated
filter)
4) Insert new pleated filter (p/n 8107-
01) and engage filter latch (by rotating
it 90° clockwise until you feel it snap
in place).
5) Raise the dirt canister (with cone
inside) to the proper location under
the power unit and engage the
latches.
6) Be certain the dirt canister and
cyclonic cone seal are “seated”
properly to the body of the unit.
ILLUS. #1
Filter
Cartridge
Filter Latch
(turn 90° to
disengage filter)
Dirt Canister
Cyclonic
Cone Seal
Cyclonic Cone
ILLUS. #2
General Power Unit
Maintenance
The simple care and maintenance
instructions included here will help
ensure trouble-free use of the central
vacuum system.
• Do not place objects on top of the
power unit. The motor could
overheat.
• Do not allow the motor to remain “on”
unless a hose is connected or an inlet
valve is open. If airflow is not permit-
ted to flow through fan blades, motor
damage may occur.
• Do not operate without a filter in place.
• Empty the dirt canister when it is
1/2 - 2/3 full.
• Change the filter cartridge once a year.
• The power unit does not require
any lubrication.
• The exterior of the power unit can
be wiped with a clean, dry cloth.
Do not use liquid cleaners or water as
an electrical shock may occur.
• For additional service contact a
qualified service person.
Troubleshooting
the System
Motor Fails to Turn On:
• Check the main fuse or circuit
breaker at the main power supply
panel of your home. Reset breaker
or replace fuses if necessary.
• Check the Power unit reset button
located above the power cord.
Pressing the button should restore
operation.
• If the circuit protector continues to
trip off after a short period of time, the
motor brushes may be worn out. Call a
qualified service person for service.
Loss of Vacuum
If the system shows a loss of vacuum
power, check the following:
• The dirt receptacle and filter may need
cleaned – follow instructions
in this guide.
• The hose may be clogged – To
check if there is an obstruction,
unplug the hose and insert an
object that is smaller then the
diameter of the hose (A butter knife
works well). Pass the object completely
through the hose, if it stops that will in-
dicate where the obstruction is located.
A dry garden hose can be inserted
into the hose to help push obstruction
through.
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM SYSTEM
WARNING
To reduce the risk of fire, electric shock or injury:
When using an electrical appliance, basic precautions should
always be followed, including the following:
• Unplug and disconnect power
before servicing.
• Do not use on wet surfaces.
• Do not allow to be used as a toy.
Close attention is necessary
when used by or near children.
• Use only as described in this
manual. Use only manufacturer’s
recommended attachments.
• Do not use with damaged cord
or plug. If appliance is not
working as it should, has been
dropped, damaged, left outdoors,
or dropped into water, return it
to a service center.
• Do not pull or carry by cord, use
cord as a handle, close a door on
cord, or pull cord around sharp
edges or corners. Do not run
appliance over cord. Keep cord
away from heated surfaces.
• Do not unplug by pulling on
cord. To unplug, grasp the plug,
not the cord.
• Do not handle system or appliance
with wet hands.
• Do not put any object into openings.
Do not use with any opening blocked.
Keep openings free of dust, lint, hair,
and anything that may reduce air flow.
• Keep hair, loose clothing, fingers,
and all parts of body away from
openings and moving parts.
• Do not pick up anything that is
burning or smoking, such as
cigarettes, matches, or hot ashes.
• Connect to a properly grounded
outlet. See grounding instructions.
• Turn off all controls before
unplugging.
• Use extra care when cleaning
on stairs.
• Do not use to pick up flammable
or combustible liquids such as
gasoline or use in areas where
they may be present.
• Do not place or store anything on top of
power unit – over-heating of motor could
occur.
• Do not use without filter in place.
SAVE THESE INSTRUCTIONS
INTENDED FOR HOUSEHOLD AND LIGHT COMMERCIAL USE.
IMPORTANT INFORMATION FOR CENTRAL VAC OWNERS
Dirt Devil
®
Models 299e, 599e & 799e
OPERATING INSTRUCTIONS
Do not vent into a wall, a ceiling, or concealed space of a building or structure.
GROUNDING METHOD
FIG. A
GROUNDING
INSTRUCTIONS
This appliance must be grounded. If it should
malfunction or break down, grounding
provides a path of least resistance for electric
current to reduce the risk of electric shock.
This appliance is equipped with a cord
having an equipment grounding conductor
and grounding plug. The plug must be
plugged into an appropriate outlet that is
properly installed and grounded in accordance
with all local codes and ordinances.
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the outlet is properly
grounded. Do not modify the plug provided
with the appliance - if it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
The 299e, 599e, and 799e appliances are for
use on a nominal 120 volt circuit and has
a grounding plug that looks like the plug
illustrated in Fig. A.
Make sure that the appliance is
connected to an outlet having the same
configuration as the plug. No adapter should
be used with this appliance.
Connect to a properly grounded outlet only.
ELECTRIC SHOCK
COULD OCCUR IF
USED ON WET
SURFACES.
CAUTION:
DO NOT USE ON WET
RUG OR FLOOR.
US LISTED
WARNING:
Dirt Devil
®
Models 299e, 599e & 799e Warranty
All Permanently installed components of the Dirt Devil
®
Built-In Central Vacuum System are
warranted to be free from defects in material and workmanship under normal use and care as
long as the original consumer purchaser owns the home of original installation or until the power
unit is removed from its original installation, whichever occurs first.
In the event of a defect in permanently installed components of the Dirt Devil
®
System, an
authorized dealer should be contacted. Repaired or replacement parts (at our option) will be
provided to you for any items under warranty. Filter cartridges are not covered under warranty
and should be replaced yearly.
Attachments
Dirt Devil
®
cleaning attachments including: turbine power brushes, non-electric hoses, wands,
tools and tool caddies are warranted to be free from defects in material and workmanship under
normal use and care for three (3) years from original date of consumer purchase. Electric power
brushes and hoses, are warranted to be free from defects in material and workmanship under
normal use and care for one (1) year from original date of consumer purchase. In the event of a
defect in a Dirt Devil
®
attachment, a repaired or replacement (at our option) part will be provided
to you for any item(s) under warranty. There is no warranty for consumable items such as light
bulbs, belts and beater brushes.
Limitations of Warranty
The lifetime warranty begins on the date of the original purchase of the unit. This warranty
specifically excludes and there is no warranty on original or replacement filter cartridges and
further excludes any damage due to shipping and handling or damage due to installation, or faulty
installation.
In order to obtain coverage under this warranty, an owner must provide proof of purchase
or have registered the Dirt Devil
®
Central Vacuum Power Unit at 1-800-822-8356 or online at
cvacregistration.com, or by completing and mailing the warranty registration card. In addition, to
recover under this warranty, an owner must have provided normal care and maintenance for the
unit including, but not limited to, replacing the filter cartridge as needed and recommended by
the Instruction Manual.
THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY FOR THIS PRODUCT. ALL OTHER
WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR WARRANTIES
OF FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED. THIS WARRANTY
COVERS ONLY THE LIABILITY AND RESPONSIBILITY DESCRIBED HEREIN, WHICH IS REPAIR
OR REPLACEMENT, AND THERE IS NO LIABILITY FOR ANY CONSEQUENTIAL, INCIDENTAL
OR SPECIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT OR THE FAILURE OF THIS
PRODUCT.
H-P Products, Inc. • 512 W. Gorgas Street • Louisville, OH 44641 • 1-800-822-8356