Zephyr AK8300ASX Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
SEP13.0101 © 2013 Zephyr Corporation
Tempest I
AK7000BS
AK7036BS
AK7042BS
READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS ....................................................... 4
INSTALLATION
Ducting Calculation Sheet
....................................... 5
Mounting Height & Clearance
................................ 6
Ducting Options
........................................................... 7
Specifi cations
............................................................... 8
Mounting the Range Hood
...................................... 9-10
Horizontal Conversion
............................................... 11-12
PBD-1200A Dual Blower
.......................................... 13-14
FEATURES & CONTROLS
Touch Controls & Features
..................................... 15-17
Optional Remote Control
......................................... 18
MAINTENANCE
Cleaning, Filters & Recirculating
.......................... 19
Lights
................................................................................ 20
TROUBLESHOOTING
................................................................ 21
WIRING DIAGRAMS
................................................................... 22
FAN CURVE DIAGRAMS
......................................................... 23-24
LIST OF PARTS AND ACCESSORIES
.............................. 25
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
b. Always turn hood ON when cooking at high heat or when fl aming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
e. Keep fan, fi lters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the fl ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fi re is small and contained in the area where it started.
3. The fi re department is being called.
4. You can fi ght the fi re with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards.
Including fi re-rated construction.
b. Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.
No for use over an outdoor grill.
OPERATION
Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- To contact a qualifi ed electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualifi ed electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
List of Materials
4
www.zephyronline.com
MODELS: AK7000BS, AK7036BS, AK7042BS
PARTS SUPPLIED
1 - Hood
2 - Baffl e fi lters (3 - AK7036BS and AK7042BS)
2 - Halogen light bulbs (pre-installed)
1 - Single internal blower and blower plate (pre-installed)
1 - Rectangular starting collar (for single blower horizontal ducting)
1 - 8” round starting collar
1 - Rectangular metal cap (for single blower horizontal ducting)
1 - Hardware package
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Dual blower kit (PBD-1200A, compatible with AK7036BS and AK7042BS only)
- Recirculating kit accessory *
*Recirculating kit only compatible with single internal blower, not with dual internal blower.
Light Bulb Removal
Suction Cup (1)
M6 x 1” (4)
M6 x 1-1/2” (4)
M6 x 2” (4)
M3.5 x 8 (4)
Wire Caps (3)
3/16 x 3/8 (4)
Washers (4)
5
Installation – Ducting Calculation Sheet
Duct pieces
To t a l
Equivalent number
length x used =
3-1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
7”-10” Round,
straight
1 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.90
0
elbow
15 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.45
0
elbow
9 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.90
0
flat elbow
24 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) =
Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6” Round,
90
0
elbow
15 Ft. x ( ) =
Ft.
6” Round,
45
0
elbow
9 Ft. x ( ) =
Ft.
Ft.
6” Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
To t a l
Equivalent number
length x used =
6” Round
wall cap
with damper
30 Ft. x ( ) =
Ft.
Round
wall cap
with damper
30 Ft. x ( ) =
Ft.
7” - 10”
Round,
90
0
elbow
15 Ft. x ( ) =
Ft.
7” - 10”
7” - 10”
Round,
45
0
elbow
9 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6” Round,
roof cap
30 Ft. x ( ) =
Ft.
7” - 10”
Round,
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 100 equivalent feet.
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round or 3-1/4” x 10” rectangular
duct must be used to maintain maximum air fl ow
effi ciency for single blower and 10” round duct for
dual blower.
Always use rigid type metal ducts only. Flexible
ducts could restrict air fl ow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fi re hazard; while
hoods mounted too high will be hard to reach and
will lose its performance and effi ciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
8” round minimum (singe blower)
10” round minimum (dual blower)
Horizontal Ducting:
3-1/4”x10” minimum (single blower)
8” round minimum (single blower)
No horizontal option available for dual blower
DAMAGE-SHIPMENT / INSTALLATION:
Please fully inspect unit for damage before
installation.
If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
If the unit is damaged by the installer (if other
than the customer), repair of replacement
must be made by arrangement between
customer and installer.
36”
26” min.
36” max.
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape.
Some Ducting Options
Installation – Ducting Options
Side wall cap
w/ gravity damper
Ductless
Recirculating
Roof Pitch w/
Flashing & Cap
Rear Ducting
8
www.zephyronline.com
Installation – Specifi cations
top
side
back
8 9/16”
1 5/8”
1”
3 1/2”
6”
*8 1/8”
or
**10 3/8”
*9 1/2”
or
**14 3/16”
2”
*7 7/8”
or
**9 15/16”
* Single Blower Dimension
** Dual Blower Dimension
R 9/16”
29 7/8” (30”)
35 7/8” (36”)
41 7/8” (42”)
3”
12”
11”
22 1/2”
34˚
C/L
9 7/8”
11/16”
7 3/8”
3 1/4”
3 1/4”
3 1/2”
1 1/4”
7 7/8”
rect. C/L
round C/L
4 1/16”
1 1/4”
2 3/16”
**14 5/16”
9
ELECTRICAL
WARNING
All Electrical work must by performed by qualifi ed electrician or person with similar technical know
how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use
extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/
ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements
and codes, purchase and install appropriate connector if necessary.
Installation – Mounting the Range Hood
Cable Lock
10
www.zephyronline.com
Installation – Mounting the Range Hood
For dual blower installation instructions please refer to
page 13.
If recirculating range hood refer to the manual
included with ZRC-07xxxB recirculating kit or on our
website prior to installing hood. Recirculating kit
compatible with 650cfm single internal blower only.
For Mounting Under a Kitchen Cabinet
1. Select preferred duct location (vertical or horizontal).
2. Begin installation by removing the baffl e fi lters.
3. Reinforce cabinet with 1”x2” wood strips if additional
strengthening is required or if cabinets are framed.
4. Temporarily position the range hood in the desired
mounting location. Measure and mark the mounting
holes, duct and electrical locations with a pencil.
NOTE: If using single internal blower a 8” round duct
opening is necessary. If using a dual internal blower,
please refer to page 14 for cut-out dimensions.
5. Drill/cut out the required openings for duct and
electrical access; make sure the duct opening is large
enough to apply duct tape.
6. Fasten hood onto cabinet with (4) M4 wood screws
provided.
7. Install electrical.
8. Install duct work and duct tape.
9. Reinstall baffl e lters.
10. Power up hood and check for leaks around duct tape.
For Mounting to a Wall
1. Select preferred duct location (vertical or horizontal).
2. Begin installation by removing the baffl e fi lters.
3. Temporarily position the range hood in the desired
mounting location. Measure and mark the mounting
holes, duct and electrical locations with a pencil.
4. Drill/cut out required openings.
5. Fasten hood onto wall with screws provided.
6. Install electrical.
7. Install duct work and duct tape.
8. Reinstall baffl e lters.
9. Power up hood and check for leaks around duct tape.
duct/silver
tape
5. Duct
opening
cutout
3. Add 1x2
wood strips
2. Baffle
filters
2. Baffle
filters
11
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8”
round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below.
NOTE: Horizontal ducting is only available for the single internal blower.
NOTE: If horizontally ducting via 3 1/4” x 10” rectangular ducting, the maximum airfl ow of 650 CFM will
be reduced to 550 CFM. Other CFM levels will not be affected.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
1. Disconnect blower plug.
2. Remove (4) screws at top of hood body attaching
blower to blower plate. Remove blower from
interior of hood body.
3. Remove (4) screws from interior of hood body
attaching blower plate to hood body. Remove
blower plate.
4. Knock out rear plates A & B for 8” round
rear ducting or plate B only for 3 1/4” x 10”
rectangular rear ducting.
A
B
Installation – Horizontal Conversion
12
www.zephyronline.com
5. Place blower inside hood as shown. 6. Attach blower to hood body from the back of
hood using (4) previously removed blower
screws and reconnect blower plug.
7. Attach 8” round duct collar or 3 1/4”x10”
rectangular duct collar to back of hood body
using (4) M3.5 x 8 screws.
8. Attach top cover plate to top of hood body using
(4) 3/16 x 3/8 screws.
Installation – Horizontal Conversion
13
1. Disconnect blower plug.
2. Remove (4) screws at top of hood body attaching
blower to single blower plate. Remove blower
from hood body.
3. Remove (4) screws from inside hood body
attaching single blower plate. Remove single
blower plate from hood body.
4. Install dual blower plate from PBD-1200A kit
into hood body. Attach by (4) screws previously
removed from step 3.
Installation – PBD-1200A Dual Blower
This range hood is equipped standard with a single blower vertical duct option. To convert from single blower
vertical ducting to dual blower vertical ducting please following the instructions below.
PBD-1200A dual blower kit compatible only with AK7036BS and AK7042BS models.
5. Install previously removed blower onto one side
of dual blower plate and attach by (4) previously
removed screws from step 2.
6. Install blower from PBD-1200A kit onto other
side of dual blower plate by (4) 3/16 x 3/8
screws.
14
www.zephyronline.com
Installation – PBD-1200A Dual Blower
NOTE: To secure the 10” transition adapter to top of hood a cut out of 14 1/2” width x 10 1/2” depth will need
to be made in the cabinet bottom.
If internal cabinet dimensions prevent this size of a cut out then the 10” transition adapter may be mounted
to the cabinet bottom rather than the top of the hood. Cut out dimensions for this type of installation are
13 1/4” width x 6 1/4” depth.
9. Place 10” round adapter (included with PBD-
1200A) on top of hood and secure with (4)
M3.5 x 8 screws.
8. Connect blower wire extrension cable from
PBD-1200A kit to new blower. Connect both
blower plugs.
7. Dual Blower screw mount locations.
15
Features & Controls – Touch Controls & Features
Lights On/Dim/Off
5 Min Delay Off
Display (speed level, delay off, filter clean)
Adjust 6 Speed Levels
Blower On/Off
1. Blower On/Off
By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1.
ACT Verification
- Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
- To verify the maximum blower CFM:
- With hood off, hold the button for 3-4 seconds. If number 6 displays = default max. CFM, if number 3 displays = max.
390 CFM, and if number 2 displays = max. 290 CFM.
2. Speed Selection
The 6 speed levels are selected by pressing to decrease and to increase speed levels. The display indicates levels
selected.
ACT Enabled Speed Selections
- When ACT is enabled, the number of blower speeds will be reduced as follows:
- 390 CFM = Maximum 3 speeds
- 290 CFM = Maximum 2 speeds
3. Delay Off
This feature is used for programmed shut down of blower 5 minutes after the function is activated. Press once, a dot flashes
in the lower right side of display indicating the function is on. The blower will completely shut down after 5 minutes.
4. Lights On/Dim/Off
Switch lights on by pressing once, press a second time to dim and again to shut off lights.
5. Display Window
The display window indicates speed levels and features such as baffle filter clean reminder, delay off and clean air indicator.
16
www.zephyronline.com
Charcoal Filter Change Reminder (charcoal filter, if installed)
When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust
and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to
be replaced after every 120 hours of use. The charcoal filters should never be cleaned or placed in a dish
washer.
The filter change reminder function in the microprocessor needs to be switched on. When switched on, the
microprocessor will elapse and count usage time and indicate by a flashing when charcoal filter
replacements are needed.
C
Setting the Filter Change Reminder
When off, hold for approximately 5 seconds.
The display will change from (exhaust mode) to
(recirculating mode) this indicates that the
elapse timer function is switched on and charcoal
filters are used.
Filter Replace Indicator
When the display starts flashing, the charcoal
filters need to be replaced.
Re-setting Function
Once filters are replaced, with hood off, press and
hold the display will appear; hold for apprimately
5 seconds until on displays disappears .
The filter change reminder is now re-set and a new
120 hour elapse cycle is initiated.
C
C
C
C
hold 5 sec. display from < - > to < C >
Set Mode
Set Mode
display < C > flashes
Change FIlters
C
hold 5 sec. display from < C > to < >
To Reset
C
Features & Controls – Touch Controls & Features
Features & Controls – Touch Controls & Features
17
Baffle Filter Clean Reminder
Aa set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from
cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle-
Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the
baffle filters need to be cleaned after every 30 hours of use. Filters can be cleaned by hand with non-
abrasive soap or in a dishwasher. Heavily soiled filters should also be soaked in grease cutting detergent
prior to cleaning.
Baffle Filter Clean Indicator
When flashes on the display, the baffle filters
needo be cleaned. This will occur after every 30
hours of use.
Reset the filter clean reminder timer after filters are
cleaned and re-installed. With hood off, press and
hold for approximately 5 seconds until on
display disappears . The filter clean reminder
function is now reset and a new 30 hours elapse
cycle is initiated.
F
Clean Filters
display < F > flashes
F
hold 5 sec. display from < F > to < >
To Reset
F
A
hold 3 sec. display from < A > to < >
To Disable
hold 3 sec.
To Enable
F
F
display < A > flashes
A
A 1 A 1
Clean Air Indicator
While Clean Air is active, the display will alternate
between , , , .
A
fter 10 minutes of Clean Air operation, the blower
will power off and the 4 hour timer will reset.
If the blower speed is changed while the Clean Air
Function is in use, the cycle will be interrupted and
the timer will reset after.
Clean Air Function
Clean Air is a feature that turns on the blower on low speed every 4 hours for 10 minutes to remove stagnant
air in the kitchen. The Clean Air function is disabled by default and must be enabled by the user.
and
and
18
www.zephyronline.com
Features & Controls – Optional Remote Control
RF REMOTE MAINTENANCE:
Clean the remote control using non abrasive detergents
Follow instructions below for replacing battery.
Using a small fl at head screwdriver, raise the cover of the battery
door (A) in order to access the battery compartment. FIG. 2.
Remove the battery and replace with battery type A23 12V.
Negative end of battery should face the spring inside the remote.
Re-install battery door and recycle old battery.
RF REMOTE FEATURES:
The RF remote control is equipped with a magnet on the back for easy
storage. The remote may be placed on any magnetic surface such as a
refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can
be inserted into a standard electrical outlet for easy storage. Note: The
remote holder does not charge the RF remote.
Maximum remote control communication distance is 15 feet from the hood.
SYNCHRONIZATION: To create a unique link between your hood and remote control please follow these steps:
1. With hood off, press and hold the “lights” button on the hood until the letter “F” shows on the display screen.
2. Press the “lights” button on the remote, the lights on the hood will turn on and synchronization is complete.
RF REMOTE FUNCTIONS:
FIG. 1
FIG. 2
Blower On / Speed Selection
Press to power on blower and cycle through all six blower speeds.
Blower On / Power Off
By pressing , the blowers will power on at the last speed setting. Press
again and the entire hood will power off, including lights.
Delay Off
Lights On / Dim / Off
Switch lights On by pressing once, again to dim and again to switch Off.
Blower On/
Speed Selection
1
1
2
3
4
Blower On/
Power Off
2
5 Min Delay Off
3
Lights On/Dim/Off
4
By pressing , the blower and lights will enter Delay Off mode. A dot will
appear in the lower right corner of the hood display indicating the function
is on. The blower will change to speed 1 and shut down after 5 minutes.
A
-
+
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compli-
ance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer
or peripheral device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
THE RF REMOVE CONTROL IS AN OPTIONAL
ACCESSORY NOT INCLUDED WITH THE HOOD AND
MUST BE PURCHASED SEPARATELY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Zephyr AK8300ASX Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues