Verkada BK11/BK21 Alarm Keypad Guide d'installation

Taper
Guide d'installation
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
Install Guide
BK11 BK21 Alarm Keypad
Document
Document Details
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
V1.0 (20230724)
(V1.0 first published 20230724)
Firmware
Firmware version can be verified on
Verkada Command command.verkada.com.
Product Model
This install guide pertains to models BK11-HW and BK21-HW.
2
Introduction
What’s in the box
What you’ll need
A working internet connection
A smartphone or laptop
A #2 Phillips screwdriver or
power drill with a #2 Phillips driver bit
3/16 inch (4.76 mm) drill bit for wall anchors
A shielded Cat5 or Cat6 Ethernet cable
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
Alarm Keypad
3
Mount Plate
(Attached to Alarm Keypad)
Connect
For easy registration and setup, scan
the QR code on the back of the
product.
If you prefer to manually register your
product, please proceed to:
verkada.com/start
T10 Security Torx Screwdriver 4 M4 x 25mm PH2 Wall Screws 4 Wall Anchors
Introduction
Overview
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
4
LED Behavior
Solid Orange
Keypad is on and booting up.
Flashing Orange
Keypad is updating firmware.
7” Touchscreen
Flashing Blue
Keypad can receive events but
cannot reach the server.
Solid Blue
Keypad is running, connected, and
receiving events.
Wiring (RS-485)
Green: B
White: A
Black:
Status LED Speaker
Microphones
Introduction
Mount Template
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
A
B
C
Wall mount
Square Junction Box (4”)
Single Gang Junction Box
Double Gang Junction Box
Use the mount template to mark the appropriate hole pattern.
5
B
B
C C
C C
A A
A A
F F
DD
E E
E E
D
E
F
European Junction Box
VESA Mount (75x75 mm)
Verkada ACC-CON-STD-1
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2022 Verkada Inc. All rights reserved.
Introduction
Technical Specifications
Power Consumption 13W
Power Input
Parameters
DC 10V-36V VDC input; 1.18A-0.33A
PoE 42V-57V VDC input; 0.30A-0.22A
Connectivity
Ethernet 10/100Mbps
Sub-GHz transceiver (863MHz - 928MHz)*
1x USB 2.0, 2x RS485
Display 7” LED-backlit multi-touch, 1024 RGB x 600 resolution
Audio Mono speaker (73 dB at 1 meter)
Dual microphones
Dimensions Tablet: Height: 135.3mm / 5.3in; Width: 182.3mm / 7.2in; Depth: 28.4mm / 1.1in
Mount: Height: 118.2mm / 4.7in; Width: 116.0mm / 4.6in; Depth: 12.5mm / 0.5in
Operating
Temperature 0°C to 40°C / 32°F to 104°F, 0-90% humidity
Weight Tablet: 480 grams / 1.1 lbs
Mount: 113 grams / 0.2 lbs
Included Accessories T10 screwdriver, x4 wall screws,
x4 drywall anchors
Mounting Options Wall Mount Bracket
6
*Sub-GHz capability is only enabled on BK21 devices.
Installation
Connect and register
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
7
Use the provided T10 Security Torx
screwdriver to loosen the security
screw.
Slide the mount plate downwards
to remove it.
Connect the Ethernet cable to the
PoE.af/.at port on the back of the
Keypad.
Please note: Bootup sequence may
take several seconds.
For easy registration and setup,
scan the QR code on the product.
If you prefer to manually register
your product, refer to the serial
number on screen and proceed to:
verkada.com/start
Installation
Mounting 1/2
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
8
Please note: Avoid mounting the Keypad in
direct sunlight for optimal device performance.
Reference the mount plate template on page 6
to mark the appropriate hole pattern on the
mounting surface.
Use the wall anchors and screws to attach the
mount plate onto the desired surface.
A
B
C
D
E
F
G
H
Wall mount
Square Junction Box (4”)
Single Gang Junction Box
Round Junction Box (4” & 3-½”)
Double Gang Junction Box
European Junction Box
VESA Mount (100x100 mm)
Verkada ACC-CON-STD-1
Use the mount template to mark the
correct hole pattern.
Cables can be routed through the
surface, or along the surface.
Option 1
Cable routing through
the surface
Option 2
Cable routing
along the surface
Installation
Mounting 2/2
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
9
Connect the Ethernet cable, and any
other cables relevant to your installation,
to the Alarm Keypad.
Please note: Bootup sequence may take
several seconds.
Engage the three hook features on the
mount plate and slide the Keypad down.
To secure, tighten the security screw,
using the provided T10 Security Torx
screwdriver.
Appendix
Compliance
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
10
FCC
Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a residential environment. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly approved by the party
responsible for compliance may void the user’s authority to operate his equipment. (Example – use only
shielded interface cables when connecting to computer or peripheral devices)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance 20cm between the radiator & your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
IC
Statement
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference;
(2) This device must accept any interference, including interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance
with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.
Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 et la
conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la
conformité de rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator
and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ou
émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres
entre le radiateur et votre corps.
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
11
Appendix
Support
Thank you for purchasing this Verkada product. If for any reason
you're experiencing issues or need assistance, please contact our
24/7 Technical Support Team immediately.
Sincerely,
The Verkada Team
verkada.com/support
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Verkada BK11/BK21 Alarm Keypad Guide d'installation

Taper
Guide d'installation

dans d''autres langues