Stuart Aquatron Assembly And Operating Instructions Manual

Taper
Assembly And Operating Instructions Manual
De-ionisers & Filters
Déioniseurs et Filtres
Assembly and Operating Instructions
Instructions de Montage et de
Fonctionnement
Aquatron
Aquatron De-ioniser ADH
& lon-exchange Cartridges ADI
Assembly Instructions
Your Aquatron De-ioniser is a highly versatile unit
which can be assembled and operated in 3 modes:-
1 BENCH MOUNTED using the base support ring
provided in the standard kit.
2 WALL MOUNTED using the optional wall bracket
catalogue number AFD.
3 IN SERIES with other Aquatron De-ionisers and Filters
using the optional plastic coupling catalogue number
ALC.
Déioniseur Aquatron (7.753.90)
A Cartouche de Resine
Echangeuse D’ions (7.753.92)
Instructions de Montage
Le déioniseur Aquatron est un ensemble facilement
adaptable à vos besoins. Il peut être utilisé:
1 SUR PAILLASSE, en utilisant le socle fourni avec le
déioniseur.
2 FIXÉ AU MUR, en utilisant le support spécial (7.753.90).
3 EN SÉRIE, avec un autre déioniseur Aquatron, ou avec le
filtre Aquatron (7.753.91), en utilisant le système de
raccordement (7.753.95).
2
Figure 1: De-ioniser Bench
Mounted
Figure 1: Installation sur paillasse
du Déioniseur Aquatron
ADH/1 (7.753.96)
Water flow valve
Robinet de sortie d’eau
Base
Socle
Pressure relief valve
Valve d’échappement
ADH/3
(7.753.98)
ADH/2
(7.753.97)
Bench Mounted Assembly
a Open the package containing the De-ioniser Housing
ADH and identify the following components:
- De-ioniser lid
- Clear plastic bowl
- Base support ring
- Large spanner for bowl removal
- Small spanner for plumbing
- Plumbing components pack ADH/1
- Plumbing components pack ADH/2
- Plumbing components pack ADH/3
b Unscrew the clear plastic bowl from the de-ioniser lid
using the large spanner.
NB: It is advisable to lubricate the rubber O ring
on the lid with silicone grease. This permits
easier assembly and disassembly.
c Open the package containing the ion-exchange
cartridges ADI. Select a cartridge and remove the
plastic end caps. Place into bowl.
d Refit the bowl and cartridge to the de-ioniser lid. Use
the spanner to ensure a secure fit with no gap
between the bowl and lid.
e Firmly position the assembled unit into the base
support ring.
f Identify the “IN” and “OUT” ports on the De-ioniser
lid.
g Onto the “OUT” port assemble the plumbing
components ADH/1 containing the water flow valve.
h Onto the “IN” port assemble EITHER:
- the plumbing components ADH/2 containing a
stainless flexible pipe and tap adapter.
OR - the plumbing components ADH/3 with plain olive
connection.
NB: The choice may depend on the type and location
of the mains water tap.
Installation sur Paillasse
a Retirer de l'emballage les composants suivants
- Tête du déioniseur
- Logement transparent
- Socle
- Clé spéciale pour demontage du logement de la
cartouche
- Clé pour assemblage des éléments de
raccordement
- Eléments de raccordement (7.753 96)
- Eléments de raccordement (7.753 97)
- Eléments de raccordement (7.753 98)
b Avec a clé spéciale, dévisser le logement de la
cartouche.
NB: L’utilisation de graisse aux silicones sur le
joint d’étanchéité facilite les manipulations
ultérieures.
c Sortir une cartouche de résine de l’emballage, en
ôter les deux bouchons et a mettre dans son
logement.
d Revisser le logement de a cartouche sur a tête des
déioniseurs. Bien visser à fond.
e Mettre le déioniseur en position sur son socle.
f Identifier les orifices d’arrivée et de sortie de l’eau
sur a tête du déioniseur.
g Assembler les éléments (7.753.96) sur l’orifice de
sortie.
h Sur l’orifice d’arrivée d’eau, deux possibilités:
- soit assembler les éléments (7.753.97)
- soit assembler les éléments (7.753.98).
Le choix entre ces deux ensembles est fonction de
l’emplacement du robinet d’arrivée d’eau.
3
i Use the small spanner provided to securely tighten
all the components.
j Now refer to OPERATING INSTRUCTIONS FOR
AQUATRON DE-IONISER.
i Bien serrer les éléments de raccordement.
j Passer maintenant aux instructions d’utilisation.
Bracket
Support mural
ADH/2
(7.753.97)
Pressure relief valve
Valve d’echappement
ADH/3
(7.753.98)
Water flow valve
Robinet de sortie d’eau
ADH/1 (7.753.96)
4
Figure 2: De-ioniser Wall Mounted
Figure 2: Fixation Murale du Déioniseur Aquatron
Wall Mounted Assembly
For this mode of assembly you require:-
- Aquatron De-ioniser Housing ADH
- lon Exchange Cartridges ADI
- Wall Mounting Bracket AFD
a Fix the wall mounting bracket to a sound wall
making sure the bracket is horizontal. Make sure the
location of the bracket allows easy access for
changing the ion-exchange cartridges.
b Unscrew the clear plastic bowl from the de-ioniser
lid using the large spanner.
NB: It is advisable to lubricate the rubber O
ring on the lid with silicone grease. This
permits easier assembly and disassembly.
c Identify the “IN” and “OUT” ports on the de-ioniser
lid.
d Position the lid inside the wall bracket with the
ports in Iine with the bracket holes. Ensure the
“OUT” port is facing the LEFT hole.
e Onto the “OUT” port assemble the plumbing
components ADH/1 containing the water flow valve.
Refer to Figure 2.
f Onto the “IN” port assemble EITHER:
- the plumbing components ADH/2 containing a
stainless flexible pipe and tap adapter.
OR - the plumbing components ADH/3 with plain olive
connection.
NB the choice may depend or the type and location
of the mains water tap.
g Use the small spanner provided to securely tighten
all the components.
h Open the package containing the ion-exchange
cartridges ADI. Select a cartridge and remove the
plastic end caps. Place into bowl.
i Refit the bowl and cartridge to the de-ioniser lid.
Use the large spanner to ensure a secure fit with no
gap between the bowl and the lid.
j Now refer to OPERATING INSTRUCTIONS FOR
AQUATRON DE-IONISER.
Installation Murale
(En option, avec l’accessoire 7.753.94)
a Fixer le support (7.753.94) au mur, en s’assurant de
son horizontalité. S’assurer que l’emplacement
choisi permet les manipulations nécessitées par le
changement de cartouche.
b Avec la clé spéciale, devisser le logement de la
cartouche.
NB: L’utilisation de graisse aux silicones sur le
joint d’étanchéité facilite les manipulations
ultérieures.
c Identifier les orifices d’arrivée et de sortie d'eau sur
la tête du deioniseur.
d Mettre la tête de déioniseur dans le support mural,
en vérifiant que l’orifice de sortie d’eau est bien en
face du trou GAUCHE du support mural.
e Sur cet orifice de sortie, assembler les éléments
(7.753.96).
f Sur l’orifice d’arrivée d’eau, deux possibilités:
- soit assembler les éléments (7.753.97)
- soit assembler les éléments (7.753.98)
Le choix entre ces deux ensembles est fonction de
l’emplacement du robinet d’arrivée d’eau.
g Bien serrer les éléments de raccordement.
h Mettre la cartouche de résine en place, en vissant
bien à fond le logement sur la tête du déioniseur.
i Passer maintenant aux instructions d’utilisation.
5
Aquatron Filter AFH & Filter
Elements AFI
Assembly Instructions
Your Aquatron Filter is a highly versatile unit which can
be assembled and operated in 3 modes.
1 BENCH MOUNTED using the base support ring
provided in the standard kit.
2 WALL MOUNTED using the optional wall bracket
catalogue number AFD.
3 IN SERIES with other Aquatron de-ionisers and
filters.
The assembly procedure for the bench mounted
(Figure 3) and wall mounted (Figure 4) modes is almost
identical to the assembly of the Aquatron De-ioniser.
Please follow the appropriate De-ioniser assembly
instructions but note the following differences:
a The bowl of the filter unit is coloured blue.
b Plumbing components ADH/3 are used for the
outlet in place of ADH/1.
c The filter elements AFI have a paper wrapping which
should be removed prior to placing in bowl.
d Ensure the filter element is positioned centrally
inside the bowl.
Filter Aquatron (7.753.91 )
Avec Filtre (7.753.93)
Instructions de montage
Le filtre Aquatron est un ensemble facilement
adaptable à vos besoins il peut être utilisé:
1 Sur paillasse, en utilisant le socle fourni avec le filtre.
2 Fixé au mur en, utilisant le support spécial
(7.753.90).
3 En série, avec un déioniseur Aquatron ou un autre
filtre Aquatron, en utilisant le système de
raccordement (7.753.95).
L’installation du filtre Aquatron sur une paillasse ou
bien fixé au mur se fait de la méme maniére que pour
le Déioniseur.
Les points suivants sont toutefois légèrement
différents:
a Le logement du filtre est bleu.
b Les éléments de raccordement (7.753.98) sont à
utiliser à la place des éléments (7.753.96).
c Le filtre doit être ôté de son emballage de protection
avant la mise en place.
d Vérifier que le filtre est bien centré dans son
logement.
6
Connecting De-ionisers and
Filters in Series
It is possible to link together any number of Aquatron
De-ioniser or Filter units in series. This merely requires
the use of the optional plastic coupling, catalogue
number ALC. One coupling is required to connect 2
units, two couplings for 3 units etc.
The following assembly procedure assumes that the
series of units will be wall mounted - using the
optional wall brackets AFD.
Raccordement du Filtre et du
Déioniseur Aquatron
II est possible de raccorder en série autant de filtres et
déioniseurs Aquatron qu’il est nécessaire Ceci est
rendu possible par l’utilisation du système de
raccordement (7.753.95).(1 système pour 2 unités, 2
systèmes pour 3 unités etc ).
La procédure de montage est la suivante (pour fixation
murale).
Figure 3: Filter Bench Mounted
Figure 3: Installation sur paillasse du filtre Aquatron
Figure 4: Filter Wall Mounted
Figure 4: Fixation murale du filtre Aquatron
ADH/3
(7.753.98)
ADH/3
(7.753.98)
ADH/2
(7.753.97)
7
a Choose a suitable location for the units which
provides
- a sound wall for fixing the wall brackets.
- convenient mains water supply.
- sufficient space to allow cartridge/filter
replacement
NB: The series of units should progress from RIGHT
to LEFT. ie - The first unit accepting the mains water
supply should be located on the right. The final unit
in the chain will hence be on the left.
b Take the final unit in the chain and mount on the
wall by following the assembly instructions for De-
ioniser and Filters on page 5. Note however the
following changes:
Into the "IN" port of the de-ioniser/filter lid fit the
coupling adapter ALC as shown in Figure 5.
c Take the lid of the next unit to be assembled and
position inside a wall bracket AFD. Into the "OUT"
port fit the free end of the threaded adapter.
d Offer this assembled lid to the previously wall
mounted unit. Connect the 3/4BSP adapter to the
3/4BSP nut on the coupling ALC. This locates the
position for the fixing of the second bracket to the
wall.
e Place the appropriate cartridges or filters into the
outer bowls and fit to the CORRECT lids. Use the
large spanner to ensure a secure fit with no gap
between the bowl and lid.
NB: It is advisable to lubricate the rubber O
ring on the lid with silicone grease. This
permits easier assembly and disassembly.
a Choisir un emplacement adapté:
- permettant une alimentation en eau facile.
- laissant suffisamment de place pour les opérations
de changement de filtre ou cartouche.
NB: Le sens de circulation d'eau doit toujours être
de la droite (entrée) vers la gauche (sortie).
b Monter l'unité finale de la chaîne (c'est-à-dire celle
de gauche) sur le mur, en suivant les instructions
spécifiques (deioniseur page 5, Filtre page 6)
II est à noter que sur l'orifice d'arrivée d'eau de
cette unité doit être mis en place l’élément
(7.753.95) selon la fig 5.
c Raccorder l'unite suivante sur le (7.753.95) et la fixer
au mur avec son support mural.
d Mettre en place cartouche et filtre, en vissant bien a
fond les logements.
NB: L’utilisation de graisse aux silicones sur le
joint d’étanchéité facilite les manipulations
ultérieures.
8
Aquatron De-ioniser
Operating Instructions
Before operating your Aquatron De-ioniser please
check that:
- the maximum water temperature will not exceed
40°C.
- the maximum water pressure will not exceed
100 psi (7 x 105Nm–2).
- the plumbing fittings including hoses, will
withstand the maximum pressure.
- the pressure relief valve is CLOSED.
- the water flow valve is OPEN.
- a container is placed below the outlet nozzle to
collect the de-ionised water.
a Turn on the mains water supply to the de-ioniser.
Observe that the unit fills with water and initially
expels air from the outlet nozzle. Eventually de-
ionised water emerges.
b Discard the first volumes of de-ionised water which
is likely to be cloudy in appearance due to the
presence of dissolved air.
Déioniseur (7.753.90)
Instructions d'utilisation
Avant utilisation, vérifier que:
- La temperature de l'eau utilisée ne dépasse pas
40°C.
- La pression maximale ne dépasse pas 100 psi (7 x
105Nm–2).
- Les tuyaux d'alimentation peuvent supporter la
pression de fonctionnement.
- La valve d'echappement est fermée.
- Le robinet de sortie est ouvert.
- Un récipient est en place, pour recueillir l'eau
déionisée produite.
a Ouvrir l'alimentation en eau L'unité se remplit d'eau
et l'air contenu dans le système est chasse.
b Ne pas conserver le début de production d'eau, qui
peut être légèrement trouble du fait de bulles d'air.
Figure 5: Series Assembly
Figure 5: Montage en série
ALC (7.753.95)
IN Arrivée OUT Sortie
9
c When the de-ionised water becomes clear in
appearance close the water flow valve.
d The de-ioniser is now ready for use and will produce
de-ionised water on demand by opening the water
flow valve.
NB: It is recommended that the de-ioniser is
left under pressure (up to 100 psi) to ensure
maximum cartridge efficiency.
Cartridge Exhaustion/Replacement
After a period of operation the ion exchange cartridge
will gradually become exhausted and the resin colour
will change from green to blue.
When the colour change wave reaches the horizontal
line marked on the de-ioniser bowl the cartridge
should be replaced. See instructions detailed on bowl.
Notes: The quality of de-ionised water from a fresh
cartridge is in the region of 1µS/cm.This deteriorates to
l5µS/cm when the colour change reaches the red
horizontal line.
The volume of de-ionised water obtained from a
cartridge is wholly dependent on the quality of the
input water. Typical values are shown below:
c Quand l’eau devient limpide, refermer le robinet de
sortie.
d Le déioniseur est maintenant prêt a l'emploi par
simple ouverture du robinet de sortie.
NB: Pour obtenir les meilleurs résultats, il est
recommandé de laisser le déioniseur sous
pression (100 psi).
Remplacement de la Cartouche
Au fur et à mesure de l'utilisation, la couleur de la
cartouche va passer du vert au bleu.
Quand le changement de couleur a atteint la ligne
rouge, sur le logement de la cartouche, celle-ci doit
être remplacée (voir les instructions sur l'appareil).
Remarque: La conductivité de l’eau est environ de
lµs/cm pour une cartouche neuve et de 15µs/cm pour
une cartouche épuisée. La durée de vie de la cartouche
est directement liée à la dureté de l'eau.
OUTPUT (litres)
PRODUCTION D’EAU DEMINERALISEE
TOTAL HARDNESS (p.p.m.)
OUTPUT/HARDNESS 15µS cut off (red line)
PRODUCTION EN FONCTION DE LA
DURETE (POINT D’ARRET 15µS/cm)
DURETE
10
Aquatron Filter Operating
Instructions
Before operating your Aquatron Filter please check
that:
- the maximum water temperature will not exceed
40°C.
- the maximum water pressure will not
exceed 100 psi (7 x 105Nm–2).
- the plumbing fittings, including hoses, will
withstand the maximum pressure.
- the pressure relief valve is CLOSED.
- a container is placed below the outlet nozzle to
collect the filtered water.
For operation, simply turn on the mains water supply.
The filter unit will gradually fill and filtered water will
emerge at the outlet nozzle.
Filter Element Replacement
After a period of operation the filter element will
gradually become blocked. This is denoted by a
reduction in the flow rate of filtered water.
The element should be replaced when the flowrate
falls below an acceptable level and certainly BEFORE it
is totally blocked.
The life of the element is wholly dependent on the
quality of the input water. Experience will indicate the
frequency of element replacement and once this is
established it is recommended that the element be
changed on a routine maintenance basis, eg. - each
week, month etc.
Filtre (7.753.91) Instructions
D'utilisation
Avant utilisation, vérifier que:
- La temperature de l'eau utilisée ne dépasse pas
40°C.
- La pression maximale d'eau ne dépasse pas 100
psi (7 x 105Nm–2).
- Les tuyaux d'alimentation peuvent supporter la
pression de fonctionnement.
- La valve d'échappement est fermée.
- Un récipient est en place, pour recueillir l’eau
filtrée produite.
Pour obtenir de l'eau filtrée, il suffit de placer un
récipient à l'orifice de sortie et d'ouvrir l'alimentation
en eau.
Remplacement du Filtre
Au fur et à mesure de l'utilisation, le filtre va avoir
tendance à se boucher, ce qui se traduira par une
diminution du débit Le remplacement doit être
effectué quand le débit est jugé insuffisant, et en tout
état de cause avant que le filtre ne soit totalement
bouché.
La durée de vie du filtre est fonction de la qualité de
l'eau et du temps d'utilisation quotidien Lorsque la
fréquence de remplacement a été déterminée, il est
conseillé de procéder à un remplacement de routine
du filtre en fonction de cette fréquence (ex : chaque
semaine, chaque mois . . . ).
11
Accessories & Spares
Cat. No. Description
ADI Pack of 3 ion charge cartridges.
AFI Pack of 3 filter elements.
ADH/1 Pack of plumbing components with
water flow valve.
ADH/2 Pack of plumbing components with
flexible pipe and tap adapter.
ADH/3 Pack of plumbing components with
plain olive connection.
AFD Wall bracket.
ALC Plastic coupling for mounting units
in series.
Accessories & Spares
Cat. No. Description
ADI Pack of 3 ion charge cartridges.
AFI Pack of 3 filter elements.
ADH/1 Pack of plumbing components with
water flow valve.
ADH/2 Pack of plumbing components with
flexible pipe and tap adapter.
ADH/3 Pack of plumbing components with
plain olive connection.
AFD Wall bracket.
ALC Plastic coupling for mounting units
in series.
Accessoires et Pieces Detachees
Référence Désignation
7.753.92 Cartouche de résine échangeuse
d’ions (boîte de 3).
7 753.93 Filtre de rechange (boîte de 3).
7.753.96 Eléments de connexion avec
robinet de sortie.
7.753.97 Eléments de connexion avec
tuyaux d’alimentation.
7.753.98 Eléments de connexion avec
embout à olive.
7.753.94 Boitier de fixation murale.
7.753.95 Element de raccordement pour
montage en série.
Bibby Scientific - UK
(Group HQ)
Beacon Road, Stone, Staffordshire,
ST15 0SA, United Kingdom
T: +44 (0)1785 812121
F: +44 (0)1785 813748
E: sales@bibby-scientific.com
Bibby Scientific France
Bâtiment le Deltaparc PN II,
7 rue du canal
BP 55437 Villepinte, 95944
ROISSY Cdg
T: 00 33 (0) 6 08 54 19 55
E: bsf@bibby-scientific.fr
Bibby Scientific - US
3 Terri Lane, Suite 10,
Burlington, NJ 08016, USA
T: +1 609 589 2560
F: +1 609 589 2571
Bibby Scientific Singapore
Prudential Tower, Level 26,
30 Cecil Street,
Singapore 049712
T: +65 6631 2976
F: +44 (0) 1785 810405
E: sales@bibby-scientific.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Stuart Aquatron Assembly And Operating Instructions Manual

Taper
Assembly And Operating Instructions Manual

dans d''autres langues