Harmonic ProStream 9000 1.0 Guide de référence

Taper
Guide de référence
ProStream®
9000
RELEASE 1.0
Blackout Management and
Configuration Guide
Rev B
© 2016 Harmonic Inc. All rights reserved. 2
February 2016
Copyright © 2000—2016 Harmonic Inc. All rights reserved. Omneon, and the Omneon logo are trademarks of Harmonic Inc.
Harmonic, the Harmonic logo, [all other Harmonic products mentioned] are trademarks, registered trademarks or service marks of Harmonic Inc. in the
United States and other countries. Dolby, Dolby Digital, Dolby Digital Plus and Dolby E are registered trademarks of Dolby Laboratories. Implementations of
AAC and HE-AAC by Fraunhofer IIS. Other company, product and service names mentioned herein may be trademarks or service marks of their respective
owners. All product and application features and specifications are subject to change at Harmonic’s sole discretion at any time and without notice.
Disclaimer
Harmonic reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be
deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. The information contained herein
is merely descriptive in nature, and does not constitute a binding offer for sale of the product described herein. Harmonic assumes no responsibility or
liability arising from the use of the products described herein, except as expressly agreed to in writing by Harmonic. The use and purchase of this product do
not convey a license under any patent rights, copyrights, trademark rights, or any intellectual property rights of Harmonic. Nothing hereunder constitutes a
representation or warranty that using any products in the manner described herein will not infringe any patents of third parties.
Third-Party Product Trademarks
Adobe® After Effects®, Photoshop®, Flash® Professional, Premier
Avid® Media Composer®
Dolby® E, Dolby Digital, Dolby Digital Plus
Jünger Audio™
Apple® QuickTime®
Microsoft® Mediaroom®
Microsoft® PlayReady®
DOCSIS® 3.0
Start Over® TV
Third-Party Copyright Notes
Dolby is a registered trademark of Dolby Laboratories. Dolby Digital, Dolby Digital Plus, Dolby Pulse, aacPlus, AC-3, and Dolby E are trademarks of Dolby
Laboratories.
Level Magic and Jünger are trademarks of Jünger Audio Studiotechnik GmbH.
MPEG Audio technology licensed from Fraunhofer IIS http://www.iis.fraunhofer.de/amm/
PitchBlue® is a registered trademark of Vigor Systems.
QuickTime and the QuickTime logo are trademarks or registered trademarks of Apple Computer, Inc., used under license therefrom.
Harmonic software uses version 3.15.4 of the FreeImage open source image library under FreeImage Public License (FIPL). See http://
freeimage.sourceforge.net for details.
Trademark Acknowledgments
Harmonic and all Harmonic product names are trademarks of Harmonic Inc. All other trademarks are the property of their respective owners.
The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in
accordance with the terms of those agreements.
May be covered by one or more of U.S. Patents No. 6,571,351; 6,696,996; 6,545,721; 6,574,225; 6,895,003; 6,522,649; 6,643,702; foreign counterparts
and pending patent applications.
This system is distributed with certain other software that may require disclosure or distribution of licenses, copyright notices, conditions of use, disclaimers
and/or other matter. Use of this system or otherwise fulfilling their conditions constitutes your acceptance of them, as necessary. Copies of such licenses,
notices, conditions, disclaimers and/or other matter are available in any one of the following locations: the LEGAL NOTICES AND LICENSES directory of the
distribution disk of the software, the root directory of the hard disk drive of the Products, or by contacting us at support@harmonicinc.com.
Notice
Information contained in this guide is subject to change without notice or obligation. While every effort has been made to ensure that the information is
accurate as of the publication date, Harmonic Inc. assumes no liability for errors or omissions. In addition, Harmonic Inc. assumes no responsibility for
damages resulting from the use of this guide.
License Agreement and Limited Warranty
1. AGREEMENT: This is a legal agreement ("Agreement") between you ("you" or "your") and Harmonic, or its appropriate local affiliate ("Harmonic", "we",
"us" or "our"). Use of our product(s) and any updates thereto purchased or validly obtained by you (the "Products"), and/or the Software (as defined below)
(collectively, the "System"), constitutes your acceptance of this Agreement. "Use" includes opening or breaking the seal on the packet containing this
Agreement, installing or downloading the Software as defined below or using the Software preloaded or embedded in your System. As used herein, the term
"Software" means the Harmonic owned software and/or firmware used in or with the Products and embedded into, provided with or loaded onto the
© 2016 Harmonic Inc. All rights reserved. 3
Products in object code format, but does not include, and this Agreement does not address, any third-party or free or open source software separately
licensed to you ("Third Party Software"). If you do not agree to this Agreement, you shall promptly return the System with a dated receipt to the seller for a
full refund.
2. LICENSE: Subject to the terms and conditions of this Agreement (including payment), we hereby grant you a nonexclusive, nontransferable license to use
the object code version of the Software embedded into, provided solely for use with or loaded onto the Product, and the accompanying documentation
("Documentation") for your internal business purposes. The Software and any authorized copies are owned by us or our suppliers, and are protected by law,
including without limitation the copyright laws and treaties of the U.S.A. and other countries. Evaluation versions of the Software may be subject to a time-
limited license key.
3. RESTRICTIONS: You (and your employees and contractors) shall not attempt to reverse engineer, disassemble, modify, translate, create derivative works
of, rent, lease (including use on a timesharing, applications service provider, service bureau or similar basis), loan, distribute, sublicense or otherwise transfer
the System, in whole or part except to the extent otherwise permitted by law. The Software may be operated on a network only if and as permitted by its
Documentation. You may make one (1) back up copy of the object code of the Software for archival purposes only. Evaluation Software will be run in a lab,
nonproductive environment. Results of any benchmark or other performance tests may not be disclosed to any third party without our prior written consent.
Title to and ownership of the Software and Documentation, and all copyright, patent, trade secret, trademark, and other intellectual property rights in the
System, shall remain our or our licensors' property. You shall not remove or alter any copyright or other proprietary rights notice on the System. We reserve
all rights not expressly granted.
4. LIMITED WARRANTY: (a) Limited Warranty. We warrant to you that, commencing on your receipt of a Product and terminating 1 year thereafter, the System
will perform substantially in accordance with its then-current appropriate Documentation. The Product (including replacements) may consist of new, used or
previously-installed components. (b) Remedies. If the System fails to comply with such warranty during such period, as your sole remedy, you must return
the same in compliance with our product return policy, and we shall, at our option, repair or replace the System, provide a workaround, or refund the fees you
paid. Replacement Systems are warranted for the original System's remaining warranty period. (c) Exclusions. EVALUATION SOFTWWARE IS LICENSED ON
AS-IS BASIS AND SUBJECT TO 4(d). We will have no obligation under this limited warranty due to: (i) negligence, misuse or abuse of the System, such as
unusual physical or electrical stress, misuse or accidents; (ii) use of the System other than in accordance with the Documentation; (iii) modifications,
alterations or repairs to the System made by a party other than us or our representative; (iv) the combination, operation or use of the System with equipment,
devices, software or data not supplied by us; (v) any third party hardware or Third Party Software, whether or not provided by us; (vi) any failure other than by
us to comply with handling, operating, environmental, storage or maintenance requirements for the System in the Documentation, including, without
limitation, temperature or humidity ranges. (d) Disclaimers. We are not responsible for your software, firmware, information, or data contained in, stored on,
or integrated with any Product returned to us for repair or replacement. SUCH LIMITED WARRANTY IS IN LIEU OF, AND WE SPECIFICALLY DISCLAIM, ANY
AND ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF
SATISFACTORY QUALITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. WE DO NOT WARRANT THAT THE
SYSTEM WILL MEET YOUR REQUIREMENTS OR BE UNINTERRUPTED OR ERROR-FREE. NO ADVICE OR INFORMATION, WHETHER ORAL OR WRITTEN,
OBTAINED FROM US OR ELSEWHERE, WILL CREATE ANY WARRANTY NOT EXPRESSLY STATED IN THIS AGREEMENT. Some jurisdictions do not allow the
exclusion of implied warranties or limitations on how long an implied warranty may last, so such exclusions may not apply to you. In that event, such implied
warranties or limitations are limited to 60 days from the date you purchased the System or the shortest period permitted by applicable law, if longer. This
warranty gives you specific legal rights and you may have other rights which vary from state to state or country to country.
5. LIMITATION OF LIABILITY: WE AND OUR AFFILIATES, SUPPLIERS, LICENSORS, OR SALES CHANNELS ("REPRESENTATIVES") SHALL NOT BE LIABLE TO
YOU FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR EXEMPLARY DAMAGES OF ANY KIND, INCLUDING BUT NOT LIMITED TO LOST
REVENUES, PROFITS OR SAVINGS, OR THE COST OF SUBSTITUTE GOODS, HOWEVER CAUSED, UNDER CONTRACT, TORT, BREACH OF WARRANTY,
NEGLIGENCE, OR OTHERWISE, EVEN IF WE WERE ADVISED OF THE POSSIBILITY OF SUCH LOSS OR DAMAGES. NOTWITHSTANDING ANY OTHER
PROVISIONS OF THIS AGREEMENT, WE AND OUR REPRESENTATIVES' TOTAL LIABILITY TO YOU ARISING FROM OR RELATING TO THIS AGREEMENT
OR THE SYSTEM SHALL BE LIMITED TO THE TOTAL PAYMENTS TO US UNDER THIS AGREEMENT FOR THE SYSTEM. THE FOREGOING LIMITATIONS
SHALL NOT APPLY TO DEATH OR PERSONAL INJURY TO PERSONS OR TANGIBLE PROPERTY IN ANY JURISDICTION WHERE APPLICABLE LAW
PROHIBITS SUCH LIMITATION. YOU ARE SOLELY RESPONSIBLE FOR BACKING UP YOUR DATA AND FILES, AND HEREBY RELEASE US AND OUR
REPRESENTATIVES FROM ANY LIABILITY OR DAMAGES DUE TO THE LOSS OF ANY SUCH DATA OR FILES. SOME JURISDICTIONS DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO SUCH EXCLUSIONS MAY NOT APPLY TO YOU.
6. CONFIDENTIALITY: Information in the System and the associated media, as well as the structure, organization and code of the Software, are proprietary to
us and contain valuable trade secrets developed or acquired at great expense to us or our suppliers. You shall not disclose to others or utilize any such
information except as expressly provided herein, except for information (i) lawfully received by the user from a third party which is not subject to
confidentiality obligations; (ii) generally available to the public without breach of this Agreement; (iii) lawfully known to the user prior to its receipt of the
System; or (iv) required by law to be disclosed.
7. SUPPORT: Updates, upgrades, fixes, maintenance or support for the System (an "Upgrade") after the limited warranty period may be available at separate
terms and fees from us. Any Upgrades shall be subject to this Agreement, except for additional or inconsistent terms we specify. Upgrades do not extend the
limited warranty period.
8. TERM; TERMINATION: The term of this Agreement shall continue unless terminated in accordance with this Section. We may terminate this Agreement at
any time upon default by you of the license provisions of this Agreement, or any other material default by you of this Agreement not cured with thirty (30)
days after written notice thereof. You may terminate this Agreement any time by terminating use of the System. Except for the first sentence of Section 2
("License") and for Section 4(a) ("Limited Warranty"), all provisions of this Agreement shall survive termination of this Agreement. Upon any such termination,
you shall certify in writing such termination and non-use to us.
9. EXPORT CONTROL: You agree that the Products and Software will not be shipped, transferred, or exported into any country or used in any manner
prohibited by the United States Export Administration Act or any other export laws, restrictions, or regulations (the "Export Laws"). You will indemnify, defend
and hold us harmless from any and all claims arising therefrom or relating thereto. In addition, if the Products or Software are identified as export controlled
items under the Export Laws, you represent and warrant that you are not a citizen, or otherwise located within, an embargoed nation (including without
limitation Iran, Iraq, Syria, Sudan, Libya, Cuba, North Korea, and Serbia) and that you are not otherwise prohibited under the Export Laws from receiving the
Software. All rights to the Products and Software are granted on condition that such rights are forfeited if you fail to comply with the terms of this Agreement.
10. U.S. GOVERNMENT RIGHTS: The Software and the documentation which accompanies the Software are "Commercial Items," as that term is defined at
48 C.F.R. §2.101, consisting of "Commercial Computer Software" and "Commercial Computer Software Documentation," as such terms are used in 48 C.F.R.
§12.212 or 48 C.F.R. §227.7202, as applicable. Consistent with 48 C.F.R. §12.212 or 48 C.F.R. §§227.7202-1 through 227.7202-4, as applicable, the
Commercial Computer Software and Commercial Computer Software Documentation are being licensed to U.S. Government as end users (a) only as
Commercial Items and (b) with only those rights as are granted to all other end users pursuant to the terms and conditions herein. Harmonic, 4300 North
First Street, San Jose, CA 95134 U.S.A.
11. GENERAL: You shall not assign, delegate or sublicense your rights or obligations under this Agreement, by operation of law or otherwise, without our
prior written consent, and any attempt without such consent shall be void. Subject to the preceding sentence, this Agreement binds and benefits permitted
successors and assigns. This Agreement is governed by California law, without regard to its conflicts of law principles. The U.N. Convention on Contracts for
the International Sale of Goods is disclaimed. If any claim arises out of this Agreement, the parties hereby submit to the exclusive jurisdiction and venue of
the federal and state courts located in Santa Clara County, California. In addition to any other rights or remedies, we shall be entitled to injunctive and other
equitable relief, without posting bond or other security, to prevent any material breach of this Agreement. We may change the terms, conditions and pricing
© 2016 Harmonic Inc. All rights reserved. 4
relating to the future licensing of our Systems and other intellectual property rights, including this Agreement, from time to time. No waiver will be implied
from conduct or failure to enforce rights nor effective unless in a writing signed on behalf of the party against whom the waiver is asserted. If any part of this
Agreement is found unenforceable, the remaining parts will be enforced to the maximum extent permitted. There are no third-party beneficiaries to this
Agreement. We are not bound by additional and/or conflicting provisions in any order, acceptance, or other correspondence unless we expressly agree in
writing. This Agreement is the complete and exclusive statement of agreement between the parties as to its subject matter and supersedes all proposals or
prior agreements, verbal or written, advertising, representations or communications concerning the System.
Every reasonable attempt has been made to comply with all licensing requirements for all components used in the system. Any oversight is unintentional and
will be remedied if brought to the attention of Harmonic at [email protected].
Documentation Conventions
This guide may use some special symbols and fonts to call your attention to important information. The following symbols appear throughout this guide:
DANGER: The Danger symbol calls your attention to information that, if ignored, can cause physical harm to
you.
CAUTION: The Caution symbol calls your attention to information that, if ignored, can adversely affect
the performance of your Harmonic product, or that can make a procedure needlessly difficult.
LASER DANGER: The Laser symbol and the Danger alert call your attention to information about the lasers in
this product that, if ignored, can cause physical harm to you.
NOTE: The Note symbol calls your attention to additional information that you will benefit from heeding. It
may be used to call attention to an especially important piece of information you need, or it may provide
additional information that applies in only some carefully delineated circumstances.
IMPORTANT: The Important symbol calls your attention to information that should stand out when you are
reading product details and procedural information.
TIP: The Tip symbol calls your attention to parenthetical information that is not necessary for performing a
given procedure, but which, if followed, might make the procedure or its subsequent steps easier, smoother, or
more efficient.
In addition to these symbols, this guide may use the following text conventions:
NOTE: You require Adobe Reader or Adobe Acrobat version 6.0 or later to open the PDF files. You can download
Adobe Reader free of charge from www.adobe.com.
Convention Explanation
Typed Command Indicates the text that you type in at the keyboard
prompt.
<Ctrl>, <Ctrl>+<Shift> A key or key sequence to press.
Links The italics in blue text to indicate Cross-references, and
hyperlinked cross-references in online documents.
Bold Indicates a button to click, or a menu item to select.
ScreenOutput The text that is displayed on a computer screen.
Emphasis The italics text used for emphasis and document
references.
Table of Contents
© 2016 Harmonic Inc. All rights reserved. 5 Blackout Management and Configuration Guide Release 1.0, Rev B
Table of Contents
Chapter 1: Blackout Management................................................................. 6
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Blackout Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Blackout Management System (BMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Linear Stream Processor (LSP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Linear Stream Switcher (LSS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Interfaces and Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Asynchronous System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Synchronous System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 2: Blackout Configuration..............................................................11
Blackout Configuration Prerequisite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Configuring Blackout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Configuring LSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Configuring LSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DNS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 3: Alarms and Log Example ...........................................................16
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Log Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Appendix A: Contacting the Technical Assistance Center .........................18
Appendix B: Safety and Regulatory Compliance Information ...................20
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Safety Symbols & Translated Safety, Warning & Caution Instructions (English) . . . . . . . . . 20
Symboles de sécurité et traduits de sécurité, d'avertissement et Attention Instructions
(français) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Sicherheit Symbole und übersetzt Sicherheit, Achtung & Vorsicht Anleitung (Deutsch) . 26
Site Preparation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Product End-of-Life Disassembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
EU Manufacturer’s Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Electromagnetic Compatibility Notices – Class A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Product Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Product Regulatory Compliance Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Product Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Compliance with additional country specific environmental, safety, and EMC standards 40
© 2016 Harmonic Inc. All rights reserved. 6 Blackout Management and Configuration Guide Release 1.0, Rev B
Chapter 1
Blackout Management
Introduction
Blackout Management for ProStream 9000 enables the user to determine the video sent to
viewers based on characteristics such as geography, or blackout zone. Two options for the
process are shown schematically in the following figures:
Figure 1–1: Asynchronous - No SCTE-35 at the source. Blackout event is generated asynchronously by
the BMS.
Chapter 1 Blackout Management
© 2016 Harmonic Inc. All rights reserved. 7 Blackout Management and Configuration Guide Release 1.0, Rev B
Terminology
Figure 1–2: Synchronous - SCTE-35 signal at source triggers the Blackout event.
Terminology
BMS Blackout Management System or ESAM server, also called
POIS
This system receives Blackout information over ESNI from
the content providers. The BMS will have the following
information:
Blackout schedule for each program and blackout zone
Database of all the Virtual IRDs (VIRD)
Database of all the Main and Alternate feeds
The BMS communicates with the LSS and LSP using the
ESAM-IO3 protocol.
POIS Placement Opportunity Information System
The POIS is a system or process that identifies and provides
descriptions of placement opportunities for media (such as
the availability to insert ads). It may contain requirements
and attributes that can include which platforms may be
used, ownership rights, and policies that are used to
coordinate the placement of media. The POIS system is
described in SCTE 130-5.
Chapter 1 Blackout Management
© 2016 Harmonic Inc. All rights reserved. 8 Blackout Management and Configuration Guide Release 1.0, Rev B
Terminology
ProStream LSP Linear Stream Processor
The LSP is the Harmonic ProStream located in the Central
Headend. The LSP supports synchronous (from incoming
SCTE35-2013) and asynchronous signaling (from the BMS),
and based on it generates SCTE35-2013 for each program
that is streaming to the IP Network. The protocol between
BMS to the LSP is the standard ESAM-IO3 protocol.
ProStream LSS Linear Stream Switcher
The LSS is the Harmonic ProStream located at the edge of
the network and is responsible for switching to and from
alternative feeds, based on BMS commands. The LSS
manages multiple Blackout zones for each input program,
meaning, multiple VIRDs for each input program. The LSS
holds a database of all the VIRDs. The LSS communicates
with the BMS via the standard ESAM-IO3 protocol.
VIRD Virtual IRD
A VIRD represents a single program at the output of the
LSS, for a specific Blackout zone, and replaces a physical
IRD that is feeding the legacy QAM plant today.
ESAM-IO3 A protocol specifying the APIs for processing real-time
signals (e.g., SCTE35 and others) and real-time manifest
generation.
It also supports asynchronous signal processing for live
streams and URI based content (ex. file reference).
ESAM herein functions as two interfaces that are used either
for signal processing and stream conditioning or for
manifest conditioning.
The first interface allows a signal acquisition system (e.g.,
transcoder, fragmenter, etc.) to submit signals to a signal
processing system and receive stream conditioning data
and directives, while the second interface allows submission
of a confirmed signal and receipt of manifest manipulation
instructions. A given device may be comprised of one or
more signal acquisition systems.
SCTE-35 A standard that describes the inline insertion of cue tones in
MPEG Transport Streams.
The full standard name is “Digital Program Insertion Cueing
Message for Cable”.
SCTE-35 is used to signal a local ad insertion opportunity or
local TV programs in the transport stream.
Chapter 1 Blackout Management
© 2016 Harmonic Inc. All rights reserved. 9 Blackout Management and Configuration Guide Release 1.0, Rev B
Blackout Components
Blackout Components
Blackout with ProStream includes the following components:
Blackout Management System (BMS)
The BMS uses blackout information that is either received from the content provider in ESNI-
protocol form, or is loaded manually.
The BMS will have the following information:
Blackout schedule for each program and blackout zone
Database of all the primary and alternate feeds
Blackout zones identified by Acquisition Point Identifier
Linear Stream Processor (LSP)
The Harmonic ProStream at the central headend acts as the LSP. It supports synchronous (from
incoming SCTE-35) and asynchronous signaling (from the BMS), and then generated SCTE-35
information for each program that is streaming to the IP network. The ESAM IO3 protocol will be
used between BMS and the LSP.
In an asynchronous system, no SCTE35 signaling in the incoming stream from content providers
for blackout but only for DPI (splicing), so LSP generates and injects the SCTE-35 (DPI) stream
based on the message *(Signal Processing Notification) it receives from BMS.
Linear Stream Switcher (LSS)
The ProStream located at the edge of the network acts as the LSS. It is responsible for switching
to and from alternate feeds based on BMS commands. The LSS manages multiple blackout zones
for each input program in the form of multiple Virtual Integrated Receiver/Decoders (VIRDs) for
each input program. The LSS communicates with the BMS over ESAM.
LSS reacts upon receiving an SCTE-35 event and notifies BMS. BMS replies with a command
for LSS - do nothing or switch.
LSS is responsible for switching to/from Network or alternate feed, per VIRD and based on
BMS commands.
LSS has a database of all VIRDS
DPI PID Digital Program Insertion
DPI refers to a specific technology which allows an MPEG
Transport Stream to be spliced into a currently flowing
MPEG Transport Stream seamlessly and with little or no
artifacts. The controlling signaling used to initiate an MPEG
is referred to as an SCTE-35 message. (For more detailed
information on MPEG Transport Stream and
SCTE-35, see Wikipedia.)
Time Signal Message (Type 6) Indicates a Blackout event.
Splice Insert Message (Type 5) Indicates and Ad Insertion event.
Chapter 1 Blackout Management
© 2016 Harmonic Inc. All rights reserved. 10 Blackout Management and Configuration Guide Release 1.0, Rev B
Interfaces and Flow
LSS can manage up to 100 blackout zones (VIRDS) for each input program.
NOTE: A VIRD represents a single program at the output of the LSS for a specific blackout zone, and
replaces the physical IRD that currently feeds legacy QAM plants.
Interfaces and Flow
Asynchronous System
The LSP receives SignalProcessingNotification asynchronously from the BMS using the ESAM-IO3
protocol.
Based on this notification, the LSP generates an SCTE-35 message and sends it to the LSS using
a Time Signal message (type 6).
The LSS receives the SCTE-35 message from the LSP and notifies the BMS using the ESAM-IO3
protocol.
The BMS replies to the LSS with a command to switch the feed for each VIRD to or from the
Network or alternate feed, or to do nothing.
The LSS switches the feed per VIRD based on the BMS commands.
Synchronous System
The LSP receives the synchronous incoming stream that contains the SCTE35-2013 signal for
Blackout from the content provider.
The LSP sends SingnalProcessingEvent via the ESAM IO3 protocol to the BMS.
The BMS confirms the validity of the signal and returns information via
SignalProcessingNotification, allowing the LSP to identify and update the start or end times of a
signal region. The call may also return relevant information, such as signal region duration.
The LSP sends the SCTE-35 message to the LSS, using a Time Signal Message (Type 6).
© 2016 Harmonic Inc. All rights reserved. 11 Blackout Management and Configuration Guide Release 1.0, Rev B
Chapter 2
Blackout Configuration
Blackout Configuration Prerequisite
Network Time Protocol (NTP) must be enabled at the platform level of each ProStream involved in
blackout operations. NTP ensures that all devices used are synchronized with Coordinated
Universal Time (UTC).
To set ProStream time according to the NTP server:
Once you set the time according to the NTP server, you cannot set the ProStream time manually.
1. Select Administration > Date & Time page:
2. To synchronize the ProStream time with the UTC time, check Enable NTP Sync.
3. In Server IP, enter the IP address of the NTP server.
Configuring Blackout
The blackout configuration procedure for the LSP and LSS involves changes at the Platform and
Service levels.
Configuring LSP
Configuring a blackout on the LSP requires that the ESAM Server be set up for the main as well as
each alternate service. POIS can also be set up.
NOTE: If POIS is not set up for LSP, then only ESAM messages sent to the device HTTP server URI (/blackout)
will affect the blackout.
To configure E SAM:
1. In Platform > ESAM Server. click New.
2. Configure the following
a. Name (the default is BMS)
b. IP Address
c. TCP Port
d. URI (the default is /BlackoutNotify)
Chapter 2 Blackout Configuration
© 2016 Harmonic Inc. All rights reserved. 12 Blackout Management and Configuration Guide Release 1.0, Rev B
Configuring Blackout
3. In Configuration > Logical Output, select a program.
4. From the drop-down menu, select Properties.
5. Select the ESAM section.
6. Select LSP.
7. Configure the following:
a. ESAM Server - open the BMS Server list and select the required server that manages the
blackout system. The list is populated with the ESAM servers configured in Platform >
ESAM.
b. Acquisition Point Identifier - enter the unique identifier of the program. This identifier is
unique for each blackout zone.
NOTE: Acquisition Point Identifier is required for each alternate service.
c. Timestamp Descriptor - check this option to include a timestamp descriptor.
d. Input DPI PID - select the input PID that carries the DPI PID.
e. Stamp Splice Time - check the box in order to enable.
f. Splice Insert - select the option required for SCTE35 operations for the service:
NOTE: SCTE35- Splice Insert - Type 5 - Used for Ad Insertion.
Always pass - Always pass to the output, bypassing the ESAM server
Always discard - Do not pass to output
POIS (Fallback: Discard) - Send to the POIS server, but upon failure do not pass to
output
POIS (Fallback: Pass) - Send to the POIS server, but upon failure pass to output
Chapter 2 Blackout Configuration
© 2016 Harmonic Inc. All rights reserved. 13 Blackout Management and Configuration Guide Release 1.0, Rev B
Configuring Blackout
g. Time Signal - select the operation required for SCTE35 operations for the service:
NOTE: SCTE35- Time Signal- Type 6- Used for Blackout.
Always pass - Always pass to the output, bypassing the ESAM server
Always discard - Do not pass to output
POIS (Fallback: Discard) - Send to the POIS server, but upon failure do not pass to
output
POIS (Fallback: Pass) - Send to the POIS server, but upon failure pass to output
h. Click OK.
NOTE: Enabling LSP for Service out also causes the following descriptors to be added: PMT 0xF0 Content
identifies descriptor, which carries Acquisition Point Identifier, and ES 0x52, Stream identifier descriptor, which
carries Component ID for remuxing on LSS.
In the following figure, both LSP and LSS service level configurations are shown:
Chapter 2 Blackout Configuration
© 2016 Harmonic Inc. All rights reserved. 14 Blackout Management and Configuration Guide Release 1.0, Rev B
Configuring Blackout
Configuring LSS
Configuring blackout on the LSS requires that POIS and ESAM are set up for the main and each
alternate service:
To configure E SAM:
1. In Platform > ESAM Server click New.
2. Enter the following:
a. Name (the default is BMS)
b. IP Address
c. TCP Port
d. URI (the default is /BlackoutNotify)
3. In Configuration > Logical Output, select a program.
4. From the drop-down menu, select Properties.
5. Select the ESAM section.
6. Select LSS.
7. Configure the Acquisition Point Identifier - enter the unique acquisition point identifier for
the program. This identifier is unique for each service.
NOTE: Acquisition Point Identifier is required for each alternate service.
a. Zone Identifier - enter the identifier of the blackout zone of the program. The zone
identifier and Acquisition Point Identifier together create a unique program identifier.
b. Input DPI PID - select the input PID that carries the DPI PID.
NOTE: LSS must have a reference DPI PID.
c. Stamp Splice Time - check the box in order to enable.
d. Splice Insert - select the option required for SCTE35 operations for the service:
POIS (Fallback: Discard)
POIS (Fallback: Pass)
e. Time Signal - select the operation required for SCTE35 operations for the service:
POIS (Fallback: Discard)
POIS (Fallback: Pass)
8. Click OK.
Emergency Switch to Main
There are two Emergency Switch options and they can be found in the GUI under: Platform >
ESAM > Emergency Switch.
Option 1 - A setting in the Emergency Switch window that can be activated automatically; Activate
this by selecting the check box after “Automatic switch to main on ESAM failure” and click Apply.
Option 2 - A button named Emergency switch to main; Click this button to directly switch all
services to main.
DNS Server
Up to four DNS IP addresses can be entered.
To add a DNS server:
1. In Administration > Remote Servers > DNS, click Add.
Chapter 2 Blackout Configuration
© 2016 Harmonic Inc. All rights reserved. 15 Blackout Management and Configuration Guide Release 1.0, Rev B
Configuring Blackout
2. Enter the IP address of the server.
3. Select the following:
a. Server port
b. Retries
c. Timeout
4. Enter the Domain name.
© 2016 Harmonic Inc. All rights reserved. 16 Blackout Management and Configuration Guide Release 1.0, Rev B
Chapter 3
Alarms and Log Example
Alarms
The following alarms are relevant for the Blackout feature and are grouped per Source Object:
Table 3–1: Output Stream
ID Alarm Message Recovery Tip
307 Can not match with alternate Check the stream identifier and ES type
of both PIDs.
Table 3–2: Output Service
ID Alarm Message Recovery Tip
67 Could Not Allocate Switch Engine Reduce the overall number of
configured SPS and/or Spliceable
services.
97 License Missing Blackout VIRD Install the missing license or contact
Harmonic's Technical Assistance
Center.
121 Alternate is missing for switching Check the Alternative source at the LSP
side. Check the Alternate
AcquisitionPointIdentify.
123 PIDs matching failed can not switch Check the compatibility of the Video
PID of the Alternate with the Video PID
of Main (ES Type).
Table 3–3: ESAM
ID Alarm Message Recovery Tip
11 POIS connection failed Failed to connect to the ESAM server.
Check the server’s IP address and
accessibility.
Chapter 3 Alarms and Log Example
© 2016 Harmonic Inc. All rights reserved. 17 Blackout Management and Configuration Guide Release 1.0, Rev B
Log Example
Log Example
© 2016 Harmonic Inc. All rights reserved. 18 Blackout Management and Configuration Guide Release 1.0, Rev B
Appendix A
Contacting the Technical Assistance Center
Harmonic Global Service and Support has many Technical Assistance Centers (TAC) located
globally, but virtually co-located where our customers can obtain technical assistance or request
on-site visits from the Regional Field Service Management team. The TAC operates a Follow-The-
Sun support model to provide Global Technical Support anytime, anywhere, through a single case
management and virtual telephone system. Depending on time of day, anywhere in the world, we
will receive and address your calls or emails in one of our global support centers. The Follow-the-
Sun model greatly benefits our customers by providing continuous problem resolution and
escalation of issues around the clock.
Report an issue online at:
http://harmonicinc.com/webform/report-issue-online
Table A–1: Technical Support Phone Numbers and Email Addresses
The Harmonic Inc. support website is:
http://www.harmonicinc.com/content/technical-support
The Harmonic Inc. software download locations are:
All Harmonic software except Cable
Edge software
https://harmonic.force.com/SWAccess/SWDownloadLogin
Cable Edge software ftp://ftp.harmonicinc.com
Region Telephone Technical Support E-mail
Americas 888.673.4896 (888.MPEG.TWO)
or +1.408.490.6477
Europe, Middle East,
and Africa
+44.1252.555.450 em[email protected]
India +91.120.498.3199 apacsupport@harmonicinc.com
Russia +7.495.926.4608 [email protected]
Mainland China +86.10.6569.5580 [email protected]
Japan +81.3.5565.6737 japansupport@harmonicinc.com
Asia Pacific – Other
Territories
+852.3184.0045
or 65.6542.0050
apacsupport@harmonicinc.com
Appendix A Contacting the Technical Assistance
Center
© 2016 Harmonic Inc. All rights reserved. 19 Blackout Management and Configuration Guide Release 1.0, Rev B
The Harmonic Inc. corporate address is:
Harmonic Inc.
4300 North First St.
San Jose, CA 95134, U.S.A.
Attn: Customer Support
The corporate telephone numbers for Harmonic Inc. are:
Tel. 1.800.788.1330 (inside the U.S.)
Tel. +1.408.542.2500 (outside the U.S.)
Fax.+1.408.542.2511
© 2016 Harmonic Inc. All rights reserved. 20 Blackout Management and Configuration Guide Release 1.0, Rev B
Appendix B
Safety and Regulatory Compliance Information
Legal Disclaimer: Information in this document is provided in connection with Harmonic
products. Unless otherwise agreed in writing Harmonic products are not designed nor intended
for any application in which the failure of the product could cause personal injury or death.
NOTE:
The information in this appendix may apply to purchased products only.
Important Safety Instructions
This section provides important safety guidelines for operators and service personnel.
Specific
warnings and cautions are found throughout the guide where they apply, but may not
appear
here. Please read and follow the important safety information, noting especially those
instructions
related to risk of fire, electric shock or injury to persons. You must adhere to the guidelines in this
document to ensure and maintain compliance with existing product certifications and approvals.
In this document, we use “product,” “equipment,” and “unit” interchangeably.
This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful
interference to radio communications if it is not installed and used in accordance with the
instructions in this manual. Operation of this equipment in a residential area is likely to cause
harmful interference If this occurs, the user will be required to correct the interference at his or
her own expense.
In event of conflict between the information in this document and information provided with the
product or on our website for a particular product, this product documentation takes precedence.
Safety Symbols & Translated Safety, Warning & Caution Instructions
(English)
To avoid personal injury or property damage, before you begin installing or replacing the product,
read, observe, and adhere to all the following safety instructions and information. Harmonic
products and/or product packaging may be marked with the safety symbols used throughout this
document, when it is necessary to alert operators, users, and service providers to pertinent safety
instructions in the manuals.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41

Harmonic ProStream 9000 1.0 Guide de référence

Taper
Guide de référence

dans d''autres langues