LIMITED WARRANTY
American Diagnostic Corporation (ADC
®
) warrants its products against defects in materials and workmanship under normal use
and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date of delivery.
2. Your ADSCOPE™ stethoscope is warranted for five years from date of purchase (all parts).
3. Your ADSCOPE™ chestpiece , binaurals, and binaural spring (metal parts only) are warranted for life.
What is Covered: Replacement of parts, and labor.
What is Not Covered: Transportation charges to and from ADC
®
. Damages caused by abuse, misuse, accident, or negligence.
Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, or
consequential damages, so this limitation may not apply to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC
®
, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY
11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the
original selling price (except where prohibited by law).
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
GARANTIE LIMITÉE
American Diagnostic Corporation (ADC
®
) garantit comme suit ses produits contre tous défauts de matériel et de fabrication dans des
conditions normales d’utilisation:
1. La garantie n’est accordée qu’à l’acheteur d’origine et entre en vigueur à la date de livraison.
2. Ce stéthoscope ADSCOPE
est garanti pour une durée d’un an à compter de la date d’achat (toutes pièces).
3. Les parties métalliques sont garanties à vie. (Le modèle no 609 est garanti 5 ans).
Ce qui est couvert: Remplacement de pièces et main d’œuvre.
Ce qui n’est pas couvert: Frais de transport à destination et en provenance de ADC
®
. Dégâts résultant d’un emploi abusif, d’une mau-
vaise utilisation, d’accidents ou de négligence. Dommages consécutifs, particuliers ou indirects. Certains états ne permettant pas l’exclu-
sion ou la limitation de dommages consécutifs, particuliers ou indirects, cette exclusion peut ne pas s’appliquer.
Pour obtenir des réparations aux termes de la garantie: Envoyer les articles port payé à ADC
®
, Attn: Service des réparations
(Repair Dept), 55 Commerce Dr., Hauppauge, NY 11788. Merci d’inclure nom, adresse, numéro de téléphone, justificatif d’achat, ainsi
qu’un bref descriptif de la nature du problème.
Garantie implicite: La durée de toute garantie implicite sera limitée aux termes de la présente garantie et la valeur ne saura en aucun
cas excéder le prix d’achat original (excepté là où l’interdit la loi).
La présente garantie accorde à l’acheteur des droits légaux spécifiques ; il peut disposer d’autres droits, lesquels varient d’un état à un autre.
GARANTÍA LIMITADA
American Diagnostic Corporation (ADC
®
) garantiza sus productos contra defectos en los materiales o de fabricación bajo condiciones de
uso y mantenimiento normales, tal como se indica a continuación:
1. Los servicios de la garantía se extienden sólo al comprador original minorista y tienen vigencia a partir de la fecha de despacho.
2. Su estetoscopio ADSCOPE
tiene garantía por un año desde la fecha de compra (todas las partes).
3. Las partes de metal están garantizadas de por vida. (El modelo 609 tiene garantía por 5 años).
Qué está cubierto: Partes de reemplazo y mano de obra.
Qué no está cubierto: Gastos de transporte a y desde ADC
®
. Los daños causados por abuso, uso incorrecto, accidentes o
negligencia. Daños fortuitos, especiales o resultantes. Algunos Estados no permiten la exclusión o limitación de daños fortuitos,
especiales o resultantes, por lo que esta limitación puede no aplicarse en su caso.
Para obtener los servicios de la garantía: Envíe el (los) ítems con franqueo pago a ADC
®
, Attn: Repair Dept., 55 Commerce Dr.,
Hauppauge, NY 11788. Incluya su nombre y dirección, número de teléfono, comprobante de compra y una nota breve explicando el
problema.
Garantía implícita: La duración de cualquier garantía implícita estará limitada a los términos de esta garantía y en ningún caso
excederá el precio de venta original (excepto en los lugares en que la ley lo prohíba).
Esta garantía le otorga derechos legales específicos, siendo posible que pueda acceder a otros derechos que varían de un estado a otro.
IB p/n 9330-00 rev 3 Printed in the U.S.A.
FOR QUESTIONS, COMMENTS, OR SUGGESTIONS
CALL TOLL FREE:
1-800-ADC-2670
POUR DES QUESTIONS, DES COMMENTAIRES,
OU LE PÉAGE D'APPEL
DE SUGGESTIONS LIBRE:
1-800-ADC-2670
PARA LAS PREGUNTAS, LOS COMENTARIOS,
O EL PEAJE DE LA LLAMADA
DE LAS SUGERENCIAS LIBRE:
1-800-ADC-2670
To Register Your Product, visit us at
www.adctoday.com
and follow the links
Pour enregistrer votre produit, rendez- visitenous à
www.adctoday.com
et suivez les liens
Para colocar su producto, visítenos en
www.adctoday.com
y siga los acoplamientos
Use, Care,
& Maintenance
Adscope 641 Sprague
ESPAÑOL
Gracias por elegir un estetoscopio ADC
®
ADSCOPE
TM
. Su nuevo estetoscopio ADC
®
ADSCOPE
TM
se diseñó para brindar una sensibilidad acústica sin igual, una durabilidad
incomparable y una comodidad insuperable. Cada componente fue diseñado cuida-
dosamente para maximizar el desempeño.
endotracheal intubation difficult.
Descripción del dispositivo y uso previsto
Este dispositivo está dirigido para uso exclusivo en diagnóstico médico. Puede utilizarse
para escuchar el corazón, los pulmones y otros sonidos corporales así como para la aus-
cultación normal. El dispositivo no se diseñó, ni se vende o está dirigido a otro uso que
no sea el indicado. endotracheal intubation difficult.
endotracheal intubation difficult.
Advertencias generales
Una nota de advertencia incluida en este manual identifica una afección o práctica
que, si no se corrige o suspende de inmediato, puede producir una lesión, una
enfermedad o la muerte del paciente.
PRECAUCIÓN:
Nunca utilice el estetoscopio sin que las olivas estén firmemente trabadas en su lugar.
endotracheal intubation difficult.
Opciones de cápsulas
El diseño del ADC
®
641 Sprague utiliza cinco accesorios intercambiables para las cápsulas
(3 campanas y 2 diafragmas) que detectan un amplio rango de frecuencias en pacientes
adultos y pediátricos. En el tambor de la cápsula se pueden colocar 2 accesorios diferentes
para que pueda optar por uno de ellos. Seleccione el que mejor se adapta para el uso que
necesita el paciente.
Los accesorios de la cápsula pueden colocarse
enroscándolos en el sentido de las agujas del reloj hasta
que estén ajustados. Para quitarlos, hágalos girar en
sentido contrario al de las agujas del reloj. (Fig. 1)
endotracheal endotracheal intubation difficult.
Selección de la cápsula
En el ADC
®
ADSCOPE™ 641 Sprague, la cápsula completa rota
180° lo que permite seleccionar el lado. (Sólo funciona el lado
seleccionado). El mecanismo patentado de la válvula ADC
®
’ vir-
tualmente elimina cualquier pérdida acústica por el lado que no
está funcionando.
Para seleccionar uno de los lados, sostenga el vástago de la
cápsula con una mano, mientras que con la otra hace girar la
cápsula hasta que escuche y sienta un “clic”. Un golpe suave
sobre el diafragma o la campana lo ayudará a determinar qué
lado está funcionando.
.
Llave de la cápsula
El diseño patentado de la cápsula y la llave ranurada del ADC
®
le permite ajustar el
accesorio para adultos o niños con la seguridad que desee
(para reducir el riesgo de pérdidas) sin el temor de no
poder quitar el anillo para reemplazar un diafragma deteri-
orado o roto (un problema que frecuentemente tienen los
estetoscopios Sprague más baratos).
Cómo reemplazar el diafragma
Para reemplazar un diafragma, quite el accesorio deseado
sosteniéndolo firmemente y haciéndolo girar en sentido
contrario al de las agujas del reloj.
Para aflojar el anillo del diafragma, inserte la llave en las
dos ranuras ubicadas dentro de la parte roscada ubicada
en la parte inferior del accesorio. Mientras sostiene el
anillo con firmeza, haga girar la llave en sentido contrario
al de las agujas del reloj para aflojar el anillo. Quite el
diafragma deteriorado y reemplácelo con uno nuevo.
Vuelva a colocar el anillo y ajústelo haciendo girar la
llave en el sentido de las agujas del reloj hasta que quede
bien ajustado.
Luego vuelva a colocar el anillo del diafragma en el tam-
bor de la cápsula haciéndolo girar en el sentido de las agujas del reloj hasta que
quede ajustado.
Como ajustar las ojivas
Para obtener el ajuste acústicamente hermético más
cómodo, haga girar cada ojiva aproximadamente 15°
hacia delante, orientándola hacia el puente de la
nariz. Simplemente haga girar cada tubo en el lugar
donde se conecta con el tubo flexible.
Cuidado y mantenimiento
• Evite el calor o el frío extremo, el contacto con solventes o aceites.
• NO lo deje expuesto a la luz solar directa durante mucho tiempo.
• Las ojivas y los tubos pueden limpiarse con alcohol o agua con poco jabón.
• Las olivas pueden desenroscarse de las ojivas para una limpieza profunda.
• Periódicamente revise que las olivas estén bien colocadas en las ojivas.
• NO sumerja el estetoscopio en líquido ni lo someta a esterilización con vapor.
• Si es necesario esterilizarlo, sólo utilice una esterilización con gas.
Replacement Parts List
!
Correct
Incorrect
Accesorio de diafragma para
adultos - para filtrar las bajas
frecuencias y acentuar los
rangos altos en adultos.
Accesorio de diafragma infantil -
para detectar soplos agudos en
bebés y niños.
Campana de 1 pulgada y 1/4 –
para detectar sonidos de frecuencia
baja y media y soplos en adultos.
Campana de 1 pulgada -
para detectar sonidos de
frecuencia baja y media, y
soplos en niños
Campana de _ de pulgada -
para detectar sonidos de
frecuencia baja y media, y
soplos en bebés
(Fig.1)
15
16
18
12
2
1
3
4
8
6
5
7
9
13
14
10
11
17
Diafragma adulto activado
Diafragma pediátrico activado
Ref. Part
No. Item# Name Qty.
1 640-01D Asamblea del tambor de Chestpiece 1
2 640-02S Anillo de retención, pediátrico 1
3 640-03S Diafragma, pediátrico 1
4 640-15 Disco de aluminio, pediátrico 1
5 640-14 Disco de aluminio, adulto 1
6 640-03 Diafragma, adulto 1
7 640-02 Anillo de retención, adulto 1
8 641-05T Tubería, 22” (espec. color) 2
9 640-16 Clip de la tubería 2
10 640-05 Binaurals con
640-09 Eartips 1
11 640-09 Eartips, negro 2
Ref. Part
No. Item# Name Qty.
12 600-06BK Eartips, negro, seta 2
13 640-10 Eartips, claro, suave 2
14 640-11 Bell, 1 1/4” 1
15 640-12 Bell, 1” 1
16 640-13 Bell, 3/4” 1
17 640-18 Bolsa accesoria 1
18 640-19 Llave de Chestpiece 1
3 640-03S Diafragma, pediátrico (repuesto) 1
6 640-03 Diafragma, adulto (repuesto) 1
ENGLISH
Thank you for choosing an ADC
®
ADSCOPE
TM
Stethoscope. Your new ADC
®
ADSCOPE
TM
stethoscope is designed to provide unsurpassed acoustic sensitivity, unri-
valled durability, and unparralleled comfort. Every component has been carefully
designed to maximize performance.
endotracheal intubation difficult.
Device Description and Intended Use
This device is intended for medical diagnostic purposes only. It can be used for listening to
heart, lung and other body sounds as well as for normal auscultation. The device is not
designed, sold or intended for use except as indicated.
endotracheal intubation difficult.
endotracheal intubation difficult.
General Warnings
A warning statement in this manual identifies a condition or practice which, if not
corrected or discontinued immediately, could lead to patient injury, illness, or death.
CAUTION:
Never use stethoscope without eartips firmly locked in place.
endotracheal intubation difficult.
Chestpiece Options
The ADC
®
641 Sprague design utilizes five different interchangeable chestpiece
attachments (3 bells and 2 diaphragms) to detect a broad frequency range in both
pediatric and adult patients. The chestpiece drum accommodates 2 different chestpiece
attachments of your choice at one time. Select the type that best suits the intended
patient application.
Chestpiece attachments can be affixed by
threading clockwise until tight. To remove, twist
in a counterclockwise direction. (Fig. 1)
endotracheal endotracheal intubation difficult.
Selection of the Chestpiece
On ADC
®
ADSCOPE
641 Sprague, the entire chestpiece
rotates 180° permitting the selection of one side.
(Only one side is operable at a time). ADC
®
s patented
valve mechanism eliminates virtually all acoustic leakage
from the inoperable side.
To select the side in operation, hold the chestpiece stem
in one hand and rotate the chestpiece with the other hand
until a click is felt and heard. A light tap on the diaphragm
or bell will help determine which side is in operation as well.
.
Chestpiece Key
ADC
®
s proprietary chestpiece design and slotted key
allows you to tighten the pediatric or adult assembly as
securely as you like (to reduce risk of loss) without fear of
being unable to disassemble the rim in order to replace a
worn or broken diaphragm (a problem that often plagues
less costly Sprague scopes).
Replacing the Diaphragm
To replace a diaphragm, remove the desired
assembly by gripping the assembly firmly and
turning counterclockwise.
To loosen the diaphragm rim, insert the key into
the two slots located within the threaded portion,
located on the underside of the assembly. While
holding the rim steady, turn the key counterclockwise
to loosen the rim. Remove worn diaphragm and replace
with new. Reassemble rim, and tighten by turning key
clockwise until tight.
Then Reassemble diaphragm rim back onto chestpiece
drum by turning clockwise until tight.
Adjusting the Binaurals
To obtain the most comfortable aoustically sealed
aural fit, rotate each binaural tube approximately 15°
forward, towards the bridge of your nose. Simply
twist each tube where it enters the tubing.
Care and Maintenance
• Avoid extreme heat, cold, solvents, or oils.
• Do NOT leave exposed to direct sunlight for prolonged periods of time.
• Binaurals and tubing can be wiped down with alcohol or mild soapy water.
• Eartips may be unscrewed from binaurals for a thorough cleaning.
• Periodically check that eartips are tightly secured to binaurals.
• Do NOT immerse stethoscope in any liquid or subject to steam sterilization.
• If sterilization is necessary, gas sterilize only.
Replacement Parts List
!
Correct
Incorrect
Adult Diaphragm
Activated
FRAÇAIS
Adult diaphragm assembly -
for filtering out lower frequencies
and accent the higher ranges
in adults.
Pediatric diaphragm assembly -
for detecting high pitched murmurs
in infants and children.
1 1/4” bell - for detecting low
and medium pitched sounds
and murmurs in adults.
1” bell - for detecting low
and medium pitched sounds
and murmurs in children.
3/4” bell - for detecting low
and medium pitched sounds
and murmurs in infants.
(Fig.1)
Ref. Part
No. Item# Name Qty.
1 640-01D Chestpiece Drum Assmbly 1
2 640-02S Retaining Ring, Ped. 1
3 640-03S Diaphragm, Ped. 1
4 640-15 Aluminum Disk, Ped. 1
5 640-14 Aluminum Disk, Adult 1
6 640-03 Diaphragm, Adult 1
7 640-02 Retaining Ring, Adult 1
8 641-05T Tubing, 22” (spec. color) 2
9 640-16 Tubing Clip 2
10 640-05 Binaurals with
640-09 Eartips 1
11 640-09 Eartips, Black 2
15
16
18
12
2
1
3
4
8
6
5
7
9
13
14
10
11
17
Ref. Part
No. Item# Name Qty.
12 600-06BK Eartips, Black, Mushroom 2
13 640-10 Eartips, Clear, Soft 2
14 640-11 Bell, 1 1/4” 1
15 640-12 Bell, 1” 1
16 640-13 Bell, 3/4” 1
17 640-18 Accessory Pouch 1
18 640-19 Chestpiece Key 1
3 640-03S Diaphragm, Ped. (spare) 1
6 640-03 Diaphragm, Adult (spare) 1
Nous vous remercions d’avoir choisi un stéthoscope ADC
®
ADSCOPE
TM
. Le nouveau
stéthoscope ADC
®
ADSCOPE
TM
est conçu pour assurer une sensibilité acoustique
exceptionnelle, une durabilité sans pareil et un confort incomparable. Chaque com-
posant a été soigneusement conçu pour maximiser la performance.
endotracheal intubation difficult.
Description et usage prévu
Cet instrument est réservé uniquement à des fins de diagnostic médical. Il peut être utilisé
pour écouter les bruits du cœur, des poumons et d’autres parties du corps, ainsi que pour
une auscultation normale. Cet appareil n’est conçu, vendu et destiné à être utilisé qu’aux
fins indiquées.
endotracheal intubation difficult.
endotracheal intubation difficult.
Avertissements d’ordre général
Dans ce manuel, un avertissement accompagne une condition ou une procédure
qui, si elle n’est pas immédiatement rectifiée ou interrompue, peut entraîner un
traumatisme, une maladie ou la mort du patient.
endotracheal intubation difficult.
MISE EN GARDE :
Ne jamais utiliser un stéthoscope sans s’assurer d’abord que les embouts auricu-
laires sont fixés en place.
endotracheal intubation difficult.
Options de pièces d’écoute
Le modèle ADC
®
641 Sprague emploie cinq différentes pièces d’écoute interchangeables (3
cloches et 2 diaphragmes) pour détecter une large gamme de fréquences tant chez les
patients adultes que pédiatriques. La pièce d’écoute permet de choisir 2 différents acces-
soires d’écoute. Sélectionner le type le mieux adapté au patient.
Pour assujettir les pièces d’écoute, les visser dans
le sens des aiguilles d’une montre. Les dévisser
dans le sens inverse pour les retirer. (Fig. 1)
endotracheal intubation difficult.
Sélection de la pièce d’écoute
Sur le stéthoscope ADC
®
ADSCOPE™ 641 Sprague, la pièce d’é-
coute en entier tourne de 180° pour permettre de sélectionner un
des deux côtés. (Un seul côté fonctionne à la fois). Le mécanisme
de valve breveté du stéthoscope ADC
®
élimine pratiquement toute
fuite acoustique du côté qui n’est pas utilisé.
Pour sélectionner le côté à utiliser, tenir d’une main la tige de
la pièce d’écoute et, de l’autre, faire tourner la pièce d’écoute
jusqu’à ce qu’un déclic se fasse entendre. On peut également
déterminer le côté qui est utilisé en tapotant légèrement sur le
diaphragme ou la cloche.
endotracheal intubation difficult.
Clé de pièce d’écoute
La conception exclusive de la pièce d’écoute du stéthoscope ADC
®
comporte une clé
encochée qui permet de contrôler le degré de serrage du modèle adulte ou pédia-
trique (pour réduire le risque de perte) sans crainte de ne
pas pouvoir retirer l’anneau pour remplacer un diaphragme
usagé ou brisé (problème souvent associé aux stétho-
scopes Sprague meilleurs marchés).
endotracheal intubation difficult.
Remplacement du diaphragme
Pour remplacer un diaphragme, tenir fermement la
pièce et la faire tourner dans le sens inverse des
aiguilles d’une montre pour la retirer.
Pour desserrer l’anneau du diaphragme, introduire la
clé dans les deux fentes situées dans la portion filetée
sous la pièce. Immobiliser l’anneau et faire tourner la
clé dans le sens inverse des aiguilles d’une montre
pour desserrer l’anneau. Retirer le diaphragme usagé
et le remplacer par un neuf. Remettre l’anneau en place
et serrer en tournant la clé dans le sens des aiguilles
d’une montre.
Remettre ensuite en place l’anneau du diaphragme sur
la pièce d’écoute en vissant à fond.
endotracheal intubation difficult.
Réglage des branches auriculaires
Pour obtenir un maximum de confort et permettre
une écoute acoustique étanche, faire pivoter chaque
branche d’environ 15° vers l’avant, en direction de
la voûte nasale, à l’endroit où elles sont raccordées
à la tubulure.
endotracheal intubation difficult.
Entretien
Eviter tous extrêmes de température et une quantité excessive de solvant ou d’huile.
Ne PAS exposer trop longtemps aux rayons du soleil.
Les branches auriculaires et la tubulure peuvent être essuyées à l’alcool ou à l’eau
légèrement savonneuse.
Les embouts auriculaires peuvent être dévissés complètement pour être
soigneusement nettoyés.
Vérifier de temps en temps que les embouts auriculaires sont bien rattachés
aux branches.
Ne PAS plonger le stéthoscope dans un liquide ni le stériliser à la vapeur.
Si une stérilisation s’avère nécessaire, le stériliser uniquement au gaz.
Liste des pièces de rechange
!
Correct
Incorrect
Diaphragme adulte - Pour filtrer
les basses fréquences et
accentuer les plages plus élevées
chez les adultes.
Diaphragme pédiatrique - Pour
détecter les murmures de tonalité
aiguë chez les nourrissons et les
enfants.
Cloche de 31.75 mm (1 1/4 po)
pour détecter les sons de tonalité
basse et moyenne et les murmures
chez les adultes.
Cloche de 25 mm (1 po) pour
détecter les sons de tonalité
basse et moyenne et les mur-
mures chez les enfants.
Cloche de 19 mm (3/4 po) pour
détecter les sons de tonalité
basse et moyenne et les mur-
mures chez les nourrissons.
(Fig.1)
15
16
18
12
2
1
3
4
8
6
5
7
9
13
14
10
11
17
Pediatric Diaphragm
Activated
Le diaphragme pédiatrique
a activé
Ref. Part
No. Item# Name Qty.
1 640-01D Assemblée de tambour de Chestpiece 1
2 640-02S Circlip, le pédiatrique 1
3 640-03S Diaphragme, le pédiatrique 1
4 640-15 Disque en aluminium, pédiatrique 1
5 640-14 Disque en aluminium, adulte 1
6 640-03 Diaphragme, adulte 1
7 640-02 Circlip, adulte 1
8 641-05T Tuyauterie, 22” (couleur de Spec.) 2
9 640-16 Agrafe de tuyauterie 2
10 640-05 Binaurals avec
640-09 Eartips 1
11 640-09 Eartips, noir 2
Ref. Part
No. Item# Name Qty.
12 600-06BK Eartips, noir, champignon 2
13 640-10 Eartips, espace libre, mou 2
14 640-11 Bell, 1 1/4” 1
15 640-12 Bell, 1” 1
16 640-13 Bell, 3/4” 1
17 640-18 Poche accessoire 1
18 640-19 Clef de Chestpiece 1
3 640-03S Diaphragme, péd. (pièce de rechange) 1
6 640-03 Diaphragme, adulte (pièce de rechange) 1
Le diaphragme adulte
a activé
  • Page 1 1
  • Page 2 2

ADC Adscope 641 Sprague Use, Care & Maintenance

Taper
Use, Care & Maintenance

dans d''autres langues