Unbranded DPA080E3WDB6 Le manuel du propriétaire

Taper
Le manuel du propriétaire
DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
*
*
PORTABLE AIR CONDITIONER
Owner’s Manual.............................1 - 20
CLIMATISEUR PORTABLE
Manuel du propriétaire.................21 - 40
AIRE ACONDICIONADO PORTÁTIL
Manual del propietario.................41 - 60
MODEL MODÈLE MODELO
DPA080E3WDB-6
DPA080E3BDB-6
DPA080HE3WDB-6
DPA080HE3BDB-6
2020.11.24
1
Welcome to the Danby family.
We are proud of our quality products and we believe in dependable service. We suggest
that you read this owner’s manual before plugging in your new appliance as it contains
important operation information, safety information, troubleshooting, and maintenance tips
to ensure the reliability and longevity of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual provided with
your new appliance.
1. Please write down your appliance information below. You must keep the original proof
of purchase receipt to validate and receive warranty services.
2. Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION
after fi lling out a product survey, at www.danby.com/support/product-registration/
Need Help?
1. Read your Owner’s Manual for installation help, troubleshooting, and maintenance
assistance.
2. Visit www.Danby.com to access self-service tools, FAQs and much more by searching
your model number in the search bar.
3. For the Quickest Customer Service, please fi ll out the web form at www.danby.com/
support. Your submission will go directly to an expert on your particular appliance.
Our average response times are between 20 minutes and 2 hours, during EST business
hours.
4. Call 1-800-263-2629 - please note that during peak hours, hold times can exceed one
hour.
Model Number: ____________________________________________________
Serial Number: ____________________________________________________
Date of Purchase: __________________________________________________
2
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining
or disposing of the air conditioner, the refrigerant
must not be allowed to vent into the open air.
SAFETY REQUIREMENTS
DANGER: Risk of fi re or explosion. Flammable
refrigerant used. Do not damage the refrigerant
circuit.
Ensure that servicing is done by factory
authorized service personnel, to minimize
product damage or safety issues.
Consult repair manual or owner’s guide before
attempting to service this product. All safety
precautions must be followed.
Dispose of properly in accordance with federal
or local regulations.
Follow handling instructions carefully.
Keep ventilation openings, in the appliance clear
of obstruction.
Do not use mechanical devices or other means
to accelerate the defrosting process.
Children should be supervised to ensure that
they do not play with the appliance.
Do not store or install the appliance near
continuously operating ignition sources such as
open fl ames or a gas stove.
Do not operate near water or in a wet room.
Do not pierce or burn.
Be aware that refrigerants may not contain an
odor.
The appliance must be stored so as to prevent
mechanical damage from occurring.
All wiring must comply with local and national
codes and must be installed by a qualifi ed
electrician. Check the available power supply and
resolve any wiring problems before installing and
operating this appliance.
The rating plate located on the right side of the
appliance just above the power cord contains
electrical and other technical data.
This appliance is not intended for use by persons
(including children) whose physical, sensory or
mental capabilities may be different or reduced,
or who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding
reduces the risk of electrical shock by providing an
escape wire for the electrical current.
This appliance has a cord that has a grounding
wire with a 3-prong plug. The power cord must be
plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be
replaced with a properly grounded 3-prong wall
outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING - Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualifi ed electrician or service agent
if the grounding instructions are not completely
understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not connect your appliance to extension
cords or together with another appliance in the
same wall outlet. Do not splice the power cord.
Do not under any circumstances cut or remove the
third ground prong from the power cord. Do not
use extension cords or ungrounded (two prongs)
adapters.
If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similar qualifi ed person in order to avoid hazard.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Any person involved with working on the refrigerant
circuit should hold a current, valid certifi cate from
an industry accredited assessment authority which
authorizes their competence to handle refrigerants
safely in accordance with an industry recognized
assessment specifi cation.
Servicing shall only be performed as recommended
by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel
shall be carried out under the supervision of
the person competent in the use of fl ammable
refrigerants.
When maintaining or disposing of the appliance the
refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
Information on servicing
1. Checks to the area: Prior to beginning work
on systems containing fl ammable refrigerants,
safety checks are necessary to ensure that the
risk of ignition is minimized. For repair to the
refrigerating system, the following precautions
shall be complied with prior to conducting work
on the system.
2. Work procedure: Work shall be undertaken
under a controlled procedure so as to minimize
the risk of a fl ammable gas or vapour being
present while the work is being performed.
3. General work area: All maintenance staff
and others working in the local area shall
be instructed on the nature of work being
carried out. Work in confi ned spaces shall be
avoided. The area around the work space shall
be sectioned off. Ensure that the conditions
within the work area have been made safe by
removing all fl ammable material.
4. Checking for the presence of refrigerant: The
area shall be checked with an appropriate
refrigerant detector prior to and during work
to ensure the technician is aware of potentially
ammable atmospheres. Ensure that the leak
detection equipment being used is suitable
for use with fl ammable refrigerants, i.e. non-
sparking, adequately sealed and intrinsically
safe.
5. Presence of fi re extinguisher: If any hot work is
to be conducted on the refrigeration equipment
or any associated parts, appropriate fi re
extinguishing equipment shall be available
to hand. Have a dry powder or C0
2
re
extinguisher adjacent to the work area.
6. No ignition sources: No person carrying out
work in relation to a refrigeration system which
involves exposing any pipe work that contains
or has contained fl ammable refrigerant shall use
any sources of ignition in such a manner that it
may lead to risk of fi re or explosion. All possible
ignition sources including cigarette smoking,
should be kept suffi ciently far away from the
site of installation, repairing, removing and
disposal during which fl ammable refrigerant can
possibly be released to the surrounding space.
Prior to work taking place, the area around the
equipment is to be surveyed to make sure there
are no fl ammable hazards or ignition risks. No
smoking signs shall be displayed.
7. Ventilated area: Ensure that the area is in the
open or that it is adequately ventilated before
breaking into the system or conducting any hot
work. A degree of ventilation shall continue
during the period that the work is carried out.
The ventilation should safely disperse any
released refrigerant and preferable expel it
externally into the atmosphere.
8. Checks to the refrigeration equipment: Where
electrical components are being changed, they
shall be fi t for the purpose and to the correct
specifi cation. At all times the manufacturer’s
maintenance and service guidelines shall be
followed. If in doubt consult the manufacturer’s
technical department for assistance.
3
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
The following checks shall be applied to installations
using fl ammable refrigerants:
The charge size is in accordance with the room
size within which the refrigerant containing
parts are installed.
The ventilation machinery and outlets are
operating adequately and are not obstructed.
If an indirect refrigerating circuit is being used,
the secondary circuit shall be checked for the
presence of refrigerant.
Marking to the equipment continues to be visible
and legible. Markings and signs that become
illegible must be corrected.
Refrigeration pipe or components are installed in
a position where they are unlikely to be exposed
to any substance which may corrode refrigerant
containing components, unless the components
are constructed of materials which are inherently
resistant to being corroded or are suitable
protected against being corroded.
9. Checks to electrical devices: Repair and
maintenance to electrical components shall
include initial safety checks and component
inspection procedures. If a fault exists that
could compromise safety, then no electrical
supply shall be connected to the circuit until it
is satisfactorily dealt with. If the fault cannot
be corrected immediately but it is necessary to
continue operation, an adequate temporary
solution shall be used. This shall be reported to
the owner of the equipment so all parties are
advised.
Initial safety checks shall include:
That capacitors are discharged. This shall be
done in a safe manner to avoid possibility of
sparking.
That no live electrical components and wiring
are exposed while charging, recovering or
purging the system.
That there is continuity of earth bonding.
Repairs to sealed components
1. During repairs to sealed components, all
electrical supplies shall be disconnected from
the equipment being worked upon prior to any
removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to
equipment during servicing then a permanently
operating form of leak detection shall be located
at the most critical point to warn of a potentially
hazardous situation.
2. To ensure that by working on electrical
components the casing is not altered in such
a way that the level of protection is affected,
particular attention shall be paid to the
following:
Damage to cables, excessive number of
connections, terminals not made to original
specifi cation, damage to seals, incorrect fi tting
of glands, etc.
Ensure the apparatus is mounted securely.
Ensure that seals or sealing materials have
not degraded such that they no longer serve
the purpose of preventing the ingress of
ammable atmospheres. Replacement parts
shall be in accordance with the manufacturer’s
specifi cations.
Note: The use of silicon sealant may inhibit the
effectiveness of some types of leak detection
equipment. Intrinsically safe components do not
have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or
capacitance loads to the circuit without ensuring
that this will not exceed the permissible voltage
and current permitted for the equipment in use.
Intrinsically safe components are the only types that
can be worked on while live in the presence of a
ammable atmosphere. The test apparatus shall
be at the correct rating. Replace components only
with parts specifi ed by the manufacturer. Other
parts may result in the ignition of refrigerant in the
atmosphere from a leak.
4
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Removal and evacuation
When breaking into the refrigerant circuit to make
repairs or for any other purpose conventional
procedures shall be used. However, it is important
that the best practice is followed since fl ammability
is a consideration. The following procedures shall
be adhered to:
• Remove refrigerant.
Purge the circuit with inert gas.
• Evacuate.
Purge again with inert gas.
Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into
the correct recovery cylinders. The system shall
be fl ushed with OFN to render the unit safe. This
process may need to be repeated several times.
Compressed air or oxygen shall not be used for
this task.
Flushing shall be achieved by breaking the
vacuum in the system with OFN and continuing
to fi ll until the working pressure is achieved, then
venting to atmosphere and fi nally pulling down
to a vacuum. This process shall be repeated until
no refrigerant is within the system. When the
nal OFN charge is used, the system shall be
vented down to atmospheric pressure to enable
work to take place. This operation is absolutely
vital is brazing operations on the pipe-work are
to take place.
Ensure that the outlet for the vacuum pump is
not close to any ignition sources and there is
ventilation available.
Charging procedures
In addition to conventional charging procedures, the
following requirements shall be followed:
Ensure that contamination of different
refrigerants does not occur when using charging
equipment. Hoses or lines shall be as short as
possible to minimize the amount of refrigerant
contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed
prior to charging the system with refrigerant.
Label the system when charging is complete, if
not already labeled.
Extreme care shall be taken not to overfi ll the
refrigeration system.
Prior to recharging the system it shall be
pressure tested with OFN. The system shall be
leak tested on completion of charging but prior
to commissioning. A follow up leak test shall be
carried out prior to leaving the site.
Cabling
Check that cabling will not be subject to wear,
corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects.
The check shall also take into account the effects of
aging or continual vibration from sources such as
compressors or fans.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of
ignition be used in the searching for or detection
of refrigerant leaks. A halide torch or any other
detector using a naked fl ame shall not be used.
Leak detection methods
The following leak detection methods are deemed
acceptable for systems containing fl ammable
refrigerants:
Electronic leak detectors shall be used to detect
ammable refrigerants but the sensitivity may
not be adequate or may need recalibration.
Detection equipment shall be calibrated in a
refrigerant-free area. Ensure that the detector is
not a potential source of ignition and is suitable
for the refrigerant used.
Leak detection equipment shall be set at a
percentage of the LFL of the refrigerant and
shall be calibrated to the refrigerant employed
and the appropriate percentage of gas (25%
maximum) is confi rmed.
Leak detection fl uids are suitable for use with
most refrigerants but the use of detergents
containing chlorine shall be avoided as the
chlorine may react with the refrigerant and
corrode the copper or pipe-work.
If a leak is suspected, all naked fl ames shall be
removed or extinguished.
If a leakage of refrigerant is found which
requires brazing, all of the refrigerant shall be
recovered from the system or isolated by means
of shut off valves in a part of the system remote
from the leak. Oxygen free nitrogen (OFN) shall
then be purged through the system both before
and during the brazing process.
5
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Decommissioning
Before carrying out this procedure, it is essential
that the technician is completely familiar with the
equipment in all its detail. It is recommended good
practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and
refrigerant sample shall be taken in case analysis is
required prior to re-use of reclaimed refrigerant. It
is essential that electrical power is available before
the task is commenced.
A. Become familiar with the equipment and its
operation.
B. Isolate system electrically.
C. Before attempting the procedure ensure that:
Mechanical handling equipment is available
if required for handling refrigerant cylinders.
All personal protective equipment is
available and being used correctly.
The recovery process is supervised at all
times by a competent person.
Recovery equipment and cylinders conform
to the appropriate standards.
D. Pump down refrigerant system, if possible.
E. If a vacuum is not possible, make a manifold so
that refrigerant can be removed from various
parts of the system.
F. Make sure that cylinder is situated on the scales
before recovery takes place.
G. Start the recovery machine and operate in
accordance with the manufacturer’s instructions.
H. Do not overfi ll cylinders. No more than 80%
volume liquid charge.
I. Do not exceed the maximum working pressure
of the cylinder, even temporarily.
J. When the cylinders have been fi lled correctly
and the process is completed, make sure that the
cylinders and the equipment are removed from
the site promptly and all isolation valves on the
equipment are closed off.
K. Recovered refrigerant shall not be charged into
another refrigeration system unless it has been
cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been
decommissioned and emptied of refrigerant. The
label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment
contains fl ammable refrigerant.
Recovery
When removing refrigerant from a system, either for
servicing or decommissioning, it is recommended
good practice that all refrigerants are removed
safely.
When transferring refrigerant into cylinders, ensure
that only appropriate refrigerant recovers cylinders
are employed. Ensure that the correct number of
cylinders for holding the total system charge are
available. All cylinders to be used are designed
for the recovered refrigerant and labeled for that
refrigerant, i.e. special cylinders for the recovery
of refrigerant. Cylinders shall be complete with
pressure relief valve and associated shut-off valves
in good working order. Empty recovery cylinders
are evacuated and, if possible, cooled before
recovery occurs.
The recovery equipment shall be in good working
order with a set of instructions concerning the
equipment that is at hand and shall be suitable for
the recovery of fl ammable refrigerants. In addition,
a set of calibrated weighing scales shall be
available and in good working order. Hoses shall
be complete with leak-free disconnect couplings
and in good condition. Before using the recovery
machine, check that is it in satisfactory working
order, has been properly maintained and that any
associated electrical components are sealed to
prevent ignition in the event of a refrigerant leak.
Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the
refrigerant supplier in the correct recovery cylinder
and the relevant waste transfer note shall be
arranged. Do not mix refrigerants in recovery units
and especially not in cylinders. If compressors or
compressor oils are to be removed, ensure that they
have been evacuated to an acceptable level to make
certain that fl ammable refrigerant does not remain
within the lubricant. The evacuation process shall be
carried out prior to returning the compressor to the
suppliers. Only electric heating to the compressor
body shall be employed to accelerate this process.
When oil is drained form a system, it shall be
carried out safely.
6
INSTALLATION INSTRUCTIONS
7
ACCESSORIES
1. Air outlet adapter
2. Exhaust hose
3. Window slider adapter
4. 8 Bolts
5. Window slider A and B
6. Window slider B and C
7. Foam seal A and B (adhesive)
8. Foam seal C (non-adhesive)
9. Drain hose
10. Remote control and batteries
1
2
3
4
5
6
7
8
9
10
2
3
1
REQUIRED TOOLS
1. Medium sized Phillips screwdriver
2. Tape measure or ruler
3. Knife or scissors
4. Saw (if window sliders need to be cut to size)
ASSEMBLING THE WINDOW KIT
1. Attach the air outlet adapter and the window
slider adapter onto either end of the exhaust
hose.
2. Insert the air outlet adapter into the back of the
appliance by placing over the air exhaust and
then pushing in the direction of the arrow to lock
into place.
3. Measure the window opening where the window
kit will be installed. Assemble as many sliders as
necessary to fi t the window. If the length of the
window requires all three sliders, use two bolts
to fasten the sliders at the correct length. If the
window opening is less that the minimum length
of a single slider, use the slider that has the hole
in it and cut it to the correct length. Make sure
not to cut the end that has the hole as this is
necessary to attach the exhaust hose adapter.
Important: The drain hose is only included on
models that include heat mode.
INSTALLATION INSTRUCTIONS
8
INSTALLING THE WINDOW KIT
The window kit can be used in either a hung
window or a sliding window application. The
images at the right are for a hung window. The
steps for a sliding window are the same.
1. Cut the adhesive foam seals A and B to the
correct length for the window. Attach them to the
window sash and frame as shown.
2. Insert the assembled window slider kit into the
window opening.
3. Cut the non-adhesive foam seal C to match
the width of the window. Insert the foam seal
between the glass and the window frame to
prevent air and insects from getting into the
room.
4. Attach the window slider adapter to the hole in
the window slider kit.
Note: It may be easier to attach the window slider
adapter to the window slider kit before placing the
kit in the window.
Note: Do not over extend or bend the hose as this
will impede air fl ow.
A
B
A
B
1
2
3
4
IMPORTANT WARNING
Do not leave this appliance unattended in a
space where people or animals who cannot
react to a malfunction are located. A malfunction
such as the exhaust hose becoming dislocated,
can cause extreme overheating or death in an
enclosed, unattended space.
9
FEATURES
1. Control panel
2. Louver
3. Display
4. Handle (both sides)
5. Casters
6. Air intake
7. Remote control holder
8. Power cord
9. Intake grille
10. Condenser drain
11. Plug xer
12. Air outlet grille
LOCATION
Place the air conditioner on a smooth, level fl oor
that is strong enough to support it and all included
accessories.
Make sure the appliance is level to minimize noise
and vibration.
The appliance must be installed near a grounded
receptacle and the overfl ow drain outlet on the rear
of the appliance must be accessible.
Do not cover air inlets or outlets or the remote
control receiver on the control panel.
The appliance requires 45 cm (17.7 inches) of
clearance on the front and sides.
The appliance requires at least 50 cm (20 inches) of
clearance on the back.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
10
CONTROL PANEL
1. Fan button: Used to set the fan speed; low,
medium, high or auto.
2. Decrease button: Used to decrease the set
temperature.
3. Increase button: Used to increase the set
temperature.
4. Mode button: Used to choose the mode; cool,
heat, fan or dry.
5. Power button: Used to turn the appliance on or
off.
Note: Certain functions can only be accessed
through the remote control.
1 2 3 4 5
DISPLAY PANEL
1. Temperature, time and icon display
2. Cool mode indicator
3. Temperature scale indicator
4. Timer indicator
5. Fan speed indicator
Low fan is indicated by one bar.
Medium fan is indicated by two bars.
High fan is indicated by three bars.
Auto fan speed is indicated by cycling bars.
6. Heat mode indicator (not available on all
models)
1
2
3
4
56
OPERATING INSTRUCTIONS
11
OPERATING MODES
Cool Mode
Press the mode button until the snowfl ake icon
appears on the display.
Use the increase and decrease buttons to choose
the desired temperature.
Use the fan button to choose the desired fan
speed.
The temperature can be set within a range of 18
- 32°C (64 - 90°F).
The exhaust hose should be installed during cool
mode to ensure the best results.
Dry Mode
Press the mode button until the “dh” symbol
appears on the display.
The fan speed will be set to auto.
The exhaust hose should be installed during dry
mode to ensure the best results.
It may be necessary to install the continuous
drain hose during dry mode to remove excess
water.
OPERATING MODES
Fan Mode
Press the mode button until the fan icon appears
on the display.
Press the fan button to choose the desired fan
speed: low, medium or high.
The exhaust hose does not need to be installed
during fan mode.
Fan mode can be used to run the fan without
engaging the cooling, heating or dehumidifying
functions.
Heat Mode
Press the mode button until the sun icon appears
on the display.
Use the increase and decrease buttons to choose
the desired temperature.
Press the fan button to choose the desired fan
speed.
The temperature can be set within a range of 13
- 27°C (55 - 81°F).
The exhaust hose should be installed during heat
mode to ensure the best results.
It may be necessary to install the continuous
drain hose during heat mode to remove excess
water.
Heat mode is not available on all models.
OPERATING INSTRUCTIONS
12
TIMER
The timer function can be used to turn the appliance
on or off after a period of time to conserve energy.
To set the timer to turn the appliance off:
1. While the appliance is running, press the timer
button. The time display will fl ash.
2. Press the timer button to choose the number of
hours before the appliance will turn off.
3. Wait 5 seconds to confi rm the setting. The timer
icon will illuminate.
To set the timer to turn the appliance on:
1. Turn the appliance on and choose the desired
mode and settings. Turn the appliance off.
2. While the appliance is turned off, press the timer
button. The time display will fl ash.
3. Press the timer button to choose the number of
hours before the appliance will turn on.
4. Wait 5 seconds to confi rm the setting. The timer
icon will illuminate.
Notes: Turning the appliance on or off at any time
or adjusting the timer setting to 0 hours will cancel
the timer settings.
CHILD LOCK
The child lock can be activated by pressing the
temperature control buttons on the remote control
at the same time for 3 seconds. The buttons on the
remote control cannot be used while the child lock is
active. To deactivate the child lock, press and hold
the temperature control buttons at the same time for
3 seconds.
The child lock can only be activated or deactivated
using the remote control.
OPERATING INSTRUCTIONS
13
FOLLOW ME
The follow me feature can only be activated from
the remote control.
The remote control has a thermostat inside of
it. Keep the remote control will you and the
air conditioner will automatically adjust the set
temperature based on the ambient temperature at
your location.
The maximum distance for the follow me feature is
8 meters (26 feet). This feature is available in cool
and auto modes.
To activate follow me, press the turbo button and
then press the temperature control buttons until the
follow me icon appears on the display and then
press the turbo button to confi rm the selection.
The remote control display will show the actual
ambient temperature at its location. The remote
control will sent a signal to the air conditioner every
20 minutes to update the set temperature. If the
air conditioner does not receive a signal from the
remote control during any 25 minute period, the
follow me feature will deactivate.
To deactivate follow me, press the turbo button and
then press the temperature control buttons until the
follow me icon fl ashes on the display and then press
the turbo button to confi rm the selection.
SLEEP
The sleep feature can be used to conserve energy
during sleeping hours. This feature can be used
during cool and heat mode.
When selected in cool mode, the set temperature
will increase by 1 degree per hour for 2 hours. The
appliance will hold the new set temperature for
6 hours before automatically returning to normal
operation.
When selected in heat mode, the set temperature
will decrease by 1 degree per hour for 3 hours.
The appliance will hold the new set temperature for
5 hours before automatically returning to normal
operation.
The sleep feature can only be activated with the
remote control and can be canceled at any time by
pressing the sleep button.
OPERATING INSTRUCTIONS
14
REMOTE CONTROL
1. Power button: Used to turn the appliance on or off.
2. Turbo button: The turbo feature is not available on this model.
3. Temperature control buttons: Used to increase or decrease
the set temperature.
4. Timer button: Used to set the timer function.
5. Mode button: Used to choose the mode.
6. Swing button: The swing feature is not available on this
model.
7. Sleep button: Used to set the sleep function.
8. Fan button: Used to set the fan speed.
9. °C/°F button: Used to change the temperature scale between
Celsius and Fahrenheit.
Note: The remote control will function within a range of 7 meters
(23 feet) of the appliance.
REMOTE DISPLAY
The digital display on the remote control will show the below
symbols. Please note that not all features may be available on
your model. If you try to use a feature that your model does not
support, the appliance will default to fan mode.
1 2
3
4
5
6
7
8
9
OPERATING INSTRUCTIONS
15
IMPORTANT
Do not dispose of batteries as unsorted municipal
waste. Refer to local laws for proper disposal of
batteries.
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference in a residential
installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation.
If this equipment does cause harmful interference
to radio or television reception, which can be
determined by turning the equipment off and on, the
user is encouraged to try to correct the interference
by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Increase the separation between the equipment
and receiver
3. Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected
4. Consult the dealer or an experienced radio/TV
technician for help
Changes or modifi cations not approved by the
party responsible for FCC compliance could void
the user’s authority to operate the equipment. This
appliance complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This device complies with Canadian CAN ICES-3
(B) / NMB-3 (B)
REPLACING THE REMOTE BATTERIES
This air conditioner comes with two AAA batteries.
Place the batteries in the remote control before use.
1. Slide the back cover from the remote downward
to expose the battery compartment.
2. Insert the batteries, ensure to match the (+) and
(-) symbols on the ends of the batteries with the
symbols inside the battery compartment.
3. Slide the battery cover back into place.
Notes:
The air conditioner will not respond if curtains,
doors or other materials block the signal from
the remote control to the unit.
Prevent any liquid from contact with the remote
control. Do not expose the remote control to
direct sunlight or heat.
If the infrared signal receiver on the indoor unit
is exposed to direct sunlight, the air conditioner
may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
Do not mix old and new batteries or batteries of
different types.
Do not leave the batteries in the remote control
if it is not going to be used for more than 2
months.
OPERATING INSTRUCTIONS
16
2. Continuous Drain
During the dry mode, you may wish to set up the
continuous drain option so that the appliance will
automatically drain collected water. Ensure that the
appliance is turned off and unplugged from the
power source before setting up the drain hose.
Remove the drain plug and attach the drain hose
that was provided with the appliance. Ensure that
there are no kinks or bends in the drain hose as this
can stop water from draining.
Place the open end of the drain hose over the
receptacle that the appliance will drain into; this
could be a basement fl oor drain, a sink or similar.
Remember that there is no drain pump in this
appliance, the continuous drain is activated by
gravity only. Ensure that the drain hose goes straight
down toward the fl oor from the drain connection.
If the hose is not positioned directly downwards,
water will not drain correctly.
WATER DRAINAGE
When the internal drain pan becomes full the
appliance will stop operating and the display
will show error code “Ft”. The air conditioning or
dehumidifying action will stop but the fan may
continue to operate.
There are two methods to drain water from the
appliance:
1. Drain Plug
1. Turn the appliance off and unplug it from the
power source.
2. Carefully move the appliance to a location
where the water can be drained.
3. Remove the drain plug and allow the water to
completely drain.
4. Replace the bottom drain plug, pressing fi rmly to
ensure a tight fi t and no leaks.
5. The “Ft” error symbol will disappear and the
appliance will resume regular function once
power is restored.
CARE & MAINTENANCE
CLEANING
Unplug the appliance before cleaning or
servicing.
Clean the cabinet with a lukewarm damp cloth
and neutral detergent. Dry the cabinet with a
lint-free dry cloth.
Do not use gasoline, paint thinner or other
chemicals to clean the appliance.
Do not wash the appliance directly under a tap
or using a hose. It may cause electrical damage.
AIR FILTER
The fi lters in this appliance that should be cleaned
every two weeks to ensure ef cient performance.
In households with animals, the air fi lters may need
to be cleaned more often and the external grills may
need to be wiped to prevent blocked air fl ow.
LONG-TERM STORAGE
1. Drain all water from the appliance.
2. Run the appliance on fan mode for half a day in
a warm room to dry the inside of the appliance
and prevent mold formation.
3. Turn off the appliance and unplug it, wrap the
cord and bundle it with tape.
4. Remove the battery from the remote control.
5. Clean the air fi lters and reinstall them.
6. Store the appliance in a cool, dark place.
Prolonged exposure to direct sunlight or extreme
heat can shorten the lifespan of the appliance.
DISPOSAL
This appliance should not be treated as regular
household waste. Check for local regulatory
compliance regarding the approved and safe
disposal of this appliance.
Do not dispose of batteries as unsorted municipal
waste. Refer to local laws for proper disposal of
batteries.
ERROR CODES
Lt - low temperature - the appliance will pause
functioning if ice forms on the internal structure;
the appliance will resume normal functioning
automatically when the ice melts
PF - sensor failure - unplug the appliance for 5
minutes to reset the internal sensors; if the error
code persists after plugging the appliance back
in, please contact consumer care for servicing
information
Ft - water tray is full - attach drain hose and drain
excess water
17
18
FREQUENTLY ASKED QUESTIONS
Can I leave my AC in place through the winter?
This is not recommended.
What are the standard wattage and amps used?
Information pertaining to watts and amps can be found on the rating plate located on the side of the unit.
When should I use the exhaust hose?
The exhaust hose should be used in cool, dry, heat and auto modes. It is not required in fan mode.
Can I use an extension cord?
No, an extension cord may not be used.
Can I extend the length of the exhaust hose?
No. The unit was designed with the length of the hose in mind and has only been tested under those
conditions. Instead use an additional fan to blow the cool air to other locations.
When should I use the drain hose?
The drain hose should be used in heat mode, dry mode or if using the continuous drain.
Where do I drain water from?
The water drains from the drainage port. If you are not using the continuous drain, the internal pan drains
from the bottom outlet.
Odors
Odour is caused by the formation of mold or mildew on internal surfaces. This can happen when there is
poor air circulation, a dirty fi lter or the air conditioner was not used for a period of time.
Ensure the fi lter is clean.
Run the unit on fan mode to remove any internal moisture.
Check for any blockages in the drain lines and ensure there are no obstructions.
Please give your unit a hard reboot. Unplug it and plug it back in after 15-20 minutes. This allows the unit
to warm and drain if there is any frost stopping draining and go back to factory settings
For odour in a unit, we suggest using an algaecide tablet. You fi rst need to turn the unit off, remove the
lower grill and fi lter from the grill at the base of the unit, and then place the tablet in base.
TROUBLESHOOTING
19
Appliance will not operate
Plug is not fully inserted into the wall outlet
Blown fuse or circuit breaker
Insuf cient cooling
• Air lter is dirty
Blocked air fl ow
Appliance size is too small for application
Noise
The ground is not level
The air fi lter is dirty or blocked
Gurgling sounds are normal, this is coolant moving inside the appliance
Odors
Formation of mold or mildew on internal wet surfaces
Place an algaecide tablet in the base pan; ensure the appliance is unplugged, remove the upper grille
and fi lter, place the tablet in the middle water tray and replace the grille and fi lter
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Unbranded DPA080E3WDB6 Le manuel du propriétaire

Taper
Le manuel du propriétaire