Danby DPA065B6WDB-6 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
*
*
PORTABLE AIR CONDITIONER
Owner’s Manual.............................1 - 18
CLIMATISEUR PORTABLE
Manuel du propriétaire.................19 - 36
AIRE ACONDICIONADO PORTÁTIL
Manual del propietario.................37 - 54
MODEL MODÈLE MODELO
DPA058B6WDB
DPA065B6WDB-6
2020.11.05
1
Welcome to the Danby family.
We are proud of our quality products and we believe in dependable service. We suggest
that you read this owner’s manual before plugging in your new appliance as it contains
important operation information, safety information, troubleshooting, and maintenance tips
to ensure the reliability and longevity of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual provided with
your new appliance.
1. Please write down your appliance information below. You must keep the original proof
of purchase receipt to validate and receive warranty services.
2. Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION
after fi lling out a product survey, at www.danby.com/support/product-registration/
Need Help?
1. Read your Owner’s Manual for installation help, troubleshooting, and maintenance
assistance.
2. Visit www.Danby.com to access self-service tools, FAQs and much more by searching
your model number in the search bar.
3. For the Quickest Customer Service, please fi ll out the web form at www.danby.com/
support. Your submission will go directly to an expert on your particular appliance.
Our average response times are between 20 minutes and 2 hours, during EST business
hours.
4. Call 1-800-263-2629 - please note that during peak hours, hold times can exceed one
hour.
Model Number: ____________________________________________________
Serial Number: ____________________________________________________
Date of Purchase: __________________________________________________
2
SAVE THESE INSTRUCTIONS!
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining
or disposing of the air conditioner, the refrigerant
must not be allowed to vent into the open air.
SAFETY REQUIREMENTS
DANGER: Risk of fi re or explosion. Flammable
refrigerant used. Do not damage the refrigerant
circuit.
Ensure that servicing is done by factory
authorized service personnel, to minimize
product damage or safety issues.
Consult repair manual or owner’s guide before
attempting to service this product. All safety
precautions must be followed.
Dispose of properly in accordance with federal
or local regulations.
Follow handling instructions carefully.
Keep ventilation openings, in the appliance clear
of obstruction.
Do not use mechanical devices or other means
to accelerate the defrosting process.
Children should be supervised to ensure that
they do not play with the appliance.
Do not store or install the appliance near
continuously operating ignition sources such as
open fl ames or a gas stove.
Do not operate near water or in a wet room.
Do not pierce or burn.
Be aware that refrigerants may not contain an
odor.
The appliance must be stored so as to prevent
mechanical damage from occurring.
All wiring must comply with local and national
codes and must be installed by a qualifi ed
electrician. Check the available power supply and
resolve any wiring problems before installing and
operating this appliance.
The rating plate located on the right side of the
appliance just above the power cord contains
electrical and other technical data.
This appliance is not intended for use by persons
(including children) whose physical, sensory or
mental capabilities may be different or reduced,
or who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding
reduces the risk of electrical shock by providing an
escape wire for the electrical current.
This appliance has a cord that has a grounding
wire with a 3-prong plug. The power cord must be
plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be
replaced with a properly grounded 3-prong wall
outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING - Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualifi ed electrician or service agent
if the grounding instructions are not completely
understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not connect your appliance to extension
cords or together with another appliance in the
same wall outlet. Do not splice the power cord.
Do not under any circumstances cut or remove the
third ground prong from the power cord. Do not
use extension cords or ungrounded (two prongs)
adapters.
If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similar qualifi ed person in order to avoid hazard.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Any person involved with working on the refrigerant
circuit should hold a current, valid certifi cate from
an industry accredited assessment authority which
authorizes their competence to handle refrigerants
safely in accordance with an industry recognized
assessment specifi cation.
Servicing shall only be performed as recommended
by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel
shall be carried out under the supervision of
the person competent in the use of fl ammable
refrigerants.
When maintaining or disposing of the appliance the
refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
Information on servicing
1. Checks to the area: Prior to beginning work
on systems containing fl ammable refrigerants,
safety checks are necessary to ensure that the
risk of ignition is minimized. For repair to the
refrigerating system, the following precautions
shall be complied with prior to conducting work
on the system.
2. Work procedure: Work shall be undertaken
under a controlled procedure so as to minimize
the risk of a fl ammable gas or vapour being
present while the work is being performed.
3. General work area: All maintenance staff
and others working in the local area shall
be instructed on the nature of work being
carried out. Work in confi ned spaces shall be
avoided. The area around the work space shall
be sectioned off. Ensure that the conditions
within the work area have been made safe by
removing all fl ammable material.
4. Checking for the presence of refrigerant: The
area shall be checked with an appropriate
refrigerant detector prior to and during work
to ensure the technician is aware of potentially
ammable atmospheres. Ensure that the leak
detection equipment being used is suitable
for use with fl ammable refrigerants, i.e. non-
sparking, adequately sealed and intrinsically
safe.
5. Presence of fi re extinguisher: If any hot work is
to be conducted on the refrigeration equipment
or any associated parts, appropriate fi re
extinguishing equipment shall be available
to hand. Have a dry powder or C0
2
re
extinguisher adjacent to the work area.
6. No ignition sources: No person carrying out
work in relation to a refrigeration system which
involves exposing any pipe work that contains
or has contained fl ammable refrigerant shall use
any sources of ignition in such a manner that it
may lead to risk of fi re or explosion. All possible
ignition sources including cigarette smoking,
should be kept suffi ciently far away from the
site of installation, repairing, removing and
disposal during which fl ammable refrigerant can
possibly be released to the surrounding space.
Prior to work taking place, the area around the
equipment is to be surveyed to make sure there
are no fl ammable hazards or ignition risks. No
smoking signs shall be displayed.
7. Ventilated area: Ensure that the area is in the
open or that it is adequately ventilated before
breaking into the system or conducting any hot
work. A degree of ventilation shall continue
during the period that the work is carried out.
The ventilation should safely disperse any
released refrigerant and preferable expel it
externally into the atmosphere.
8. Checks to the refrigeration equipment: Where
electrical components are being changed, they
shall be fi t for the purpose and to the correct
specifi cation. At all times the manufacturer’s
maintenance and service guidelines shall be
followed. If in doubt consult the manufacturer’s
technical department for assistance.
3
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
The following checks shall be applied to installations
using fl ammable refrigerants:
The charge size is in accordance with the room
size within which the refrigerant containing
parts are installed.
The ventilation machinery and outlets are
operating adequately and are not obstructed.
If an indirect refrigerating circuit is being used,
the secondary circuit shall be checked for the
presence of refrigerant.
Marking to the equipment continues to be visible
and legible. Markings and signs that become
illegible must be corrected.
Refrigeration pipe or components are installed in
a position where they are unlikely to be exposed
to any substance which may corrode refrigerant
containing components, unless the components
are constructed of materials which are inherently
resistant to being corroded or are suitable
protected against being corroded.
9. Checks to electrical devices: Repair and
maintenance to electrical components shall
include initial safety checks and component
inspection procedures. If a fault exists that
could compromise safety, then no electrical
supply shall be connected to the circuit until it
is satisfactorily dealt with. If the fault cannot
be corrected immediately but it is necessary to
continue operation, an adequate temporary
solution shall be used. This shall be reported to
the owner of the equipment so all parties are
advised.
Initial safety checks shall include:
That capacitors are discharged. This shall be
done in a safe manner to avoid possibility of
sparking.
That no live electrical components and wiring
are exposed while charging, recovering or
purging the system.
That there is continuity of earth bonding.
Repairs to sealed components
1. During repairs to sealed components, all
electrical supplies shall be disconnected from
the equipment being worked upon prior to any
removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to
equipment during servicing then a permanently
operating form of leak detection shall be located
at the most critical point to warn of a potentially
hazardous situation.
2. To ensure that by working on electrical
components the casing is not altered in such
a way that the level of protection is affected,
particular attention shall be paid to the
following:
Damage to cables, excessive number of
connections, terminals not made to original
specifi cation, damage to seals, incorrect fi tting
of glands, etc.
Ensure the apparatus is mounted securely.
Ensure that seals or sealing materials have
not degraded such that they no longer serve
the purpose of preventing the ingress of
ammable atmospheres. Replacement parts
shall be in accordance with the manufacturer’s
specifi cations.
Note: The use of silicon sealant may inhibit the
effectiveness of some types of leak detection
equipment. Intrinsically safe components do not
have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or
capacitance loads to the circuit without ensuring
that this will not exceed the permissible voltage
and current permitted for the equipment in use.
Intrinsically safe components are the only types that
can be worked on while live in the presence of a
ammable atmosphere. The test apparatus shall
be at the correct rating. Replace components only
with parts specifi ed by the manufacturer. Other
parts may result in the ignition of refrigerant in the
atmosphere from a leak.
4
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Removal and evacuation
When breaking into the refrigerant circuit to make
repairs or for any other purpose conventional
procedures shall be used. However, it is important
that the best practice is followed since fl ammability
is a consideration. The following procedures shall
be adhered to:
• Remove refrigerant.
Purge the circuit with inert gas.
• Evacuate.
Purge again with inert gas.
Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into
the correct recovery cylinders. The system shall
be fl ushed with OFN to render the unit safe. This
process may need to be repeated several times.
Compressed air or oxygen shall not be used for
this task.
Flushing shall be achieved by breaking the
vacuum in the system with OFN and continuing
to fi ll until the working pressure is achieved, then
venting to atmosphere and fi nally pulling down
to a vacuum. This process shall be repeated until
no refrigerant is within the system. When the
nal OFN charge is used, the system shall be
vented down to atmospheric pressure to enable
work to take place. This operation is absolutely
vital is brazing operations on the pipe-work are
to take place.
Ensure that the outlet for the vacuum pump is
not close to any ignition sources and there is
ventilation available.
Charging procedures
In addition to conventional charging procedures, the
following requirements shall be followed:
Ensure that contamination of different
refrigerants does not occur when using charging
equipment. Hoses or lines shall be as short as
possible to minimize the amount of refrigerant
contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed
prior to charging the system with refrigerant.
Label the system when charging is complete, if
not already labeled.
Extreme care shall be taken not to overfi ll the
refrigeration system.
Prior to recharging the system it shall be
pressure tested with OFN. The system shall be
leak tested on completion of charging but prior
to commissioning. A follow up leak test shall be
carried out prior to leaving the site.
Cabling
Check that cabling will not be subject to wear,
corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects.
The check shall also take into account the effects of
aging or continual vibration from sources such as
compressors or fans.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of
ignition be used in the searching for or detection
of refrigerant leaks. A halide torch or any other
detector using a naked fl ame shall not be used.
Leak detection methods
The following leak detection methods are deemed
acceptable for systems containing fl ammable
refrigerants:
Electronic leak detectors shall be used to detect
ammable refrigerants but the sensitivity may
not be adequate or may need recalibration.
Detection equipment shall be calibrated in a
refrigerant-free area. Ensure that the detector is
not a potential source of ignition and is suitable
for the refrigerant used.
Leak detection equipment shall be set at a
percentage of the LFL of the refrigerant and
shall be calibrated to the refrigerant employed
and the appropriate percentage of gas (25%
maximum) is confi rmed.
Leak detection fl uids are suitable for use with
most refrigerants but the use of detergents
containing chlorine shall be avoided as the
chlorine may react with the refrigerant and
corrode the copper or pipe-work.
If a leak is suspected, all naked fl ames shall be
removed or extinguished.
If a leakage of refrigerant is found which
requires brazing, all of the refrigerant shall be
recovered from the system or isolated by means
of shut off valves in a part of the system remote
from the leak. Oxygen free nitrogen (OFN) shall
then be purged through the system both before
and during the brazing process.
5
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Decommissioning
Before carrying out this procedure, it is essential
that the technician is completely familiar with the
equipment in all its detail. It is recommended good
practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and
refrigerant sample shall be taken in case analysis is
required prior to re-use of reclaimed refrigerant. It
is essential that electrical power is available before
the task is commenced.
A. Become familiar with the equipment and its
operation.
B. Isolate system electrically.
C. Before attempting the procedure ensure that:
Mechanical handling equipment is available
if required for handling refrigerant cylinders.
All personal protective equipment is
available and being used correctly.
The recovery process is supervised at all
times by a competent person.
Recovery equipment and cylinders conform
to the appropriate standards.
D. Pump down refrigerant system, if possible.
E. If a vacuum is not possible, make a manifold so
that refrigerant can be removed from various
parts of the system.
F. Make sure that cylinder is situated on the scales
before recovery takes place.
G. Start the recovery machine and operate in
accordance with the manufacturer’s instructions.
H. Do not overfi ll cylinders. No more than 80%
volume liquid charge.
I. Do not exceed the maximum working pressure
of the cylinder, even temporarily.
J. When the cylinders have been fi lled correctly
and the process is completed, make sure that the
cylinders and the equipment are removed from
the site promptly and all isolation valves on the
equipment are closed off.
K. Recovered refrigerant shall not be charged into
another refrigeration system unless it has been
cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been
decommissioned and emptied of refrigerant. The
label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment
contains fl ammable refrigerant.
Recovery
When removing refrigerant from a system, either for
servicing or decommissioning, it is recommended
good practice that all refrigerants are removed
safely.
When transferring refrigerant into cylinders, ensure
that only appropriate refrigerant recovers cylinders
are employed. Ensure that the correct number of
cylinders for holding the total system charge are
available. All cylinders to be used are designed
for the recovered refrigerant and labeled for that
refrigerant, i.e. special cylinders for the recovery
of refrigerant. Cylinders shall be complete with
pressure relief valve and associated shut-off valves
in good working order. Empty recovery cylinders
are evacuated and, if possible, cooled before
recovery occurs.
The recovery equipment shall be in good working
order with a set of instructions concerning the
equipment that is at hand and shall be suitable for
the recovery of fl ammable refrigerants. In addition,
a set of calibrated weighing scales shall be
available and in good working order. Hoses shall
be complete with leak-free disconnect couplings
and in good condition. Before using the recovery
machine, check that is it in satisfactory working
order, has been properly maintained and that any
associated electrical components are sealed to
prevent ignition in the event of a refrigerant leak.
Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the
refrigerant supplier in the correct recovery cylinder
and the relevant waste transfer note shall be
arranged. Do not mix refrigerants in recovery units
and especially not in cylinders. If compressors or
compressor oils are to be removed, ensure that they
have been evacuated to an acceptable level to make
certain that fl ammable refrigerant does not remain
within the lubricant. The evacuation process shall be
carried out prior to returning the compressor to the
suppliers. Only electric heating to the compressor
body shall be employed to accelerate this process.
When oil is drained form a system, it shall be
carried out safely.
6
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
7
ACCESSORIES
1. Air outlet adapter
2. Exhaust hose
3. Window slider adapter
4. 2 Bolts
5. Window slider A
6. Window slider B and C
7. Foam seal A (adhesive)
8. Foam seal B (adhesive)
9. Foam seal C (non-adhesive)
10. Security bracket and 2 screws
11. Drain hose
12. Power cord storage band
13. Remote control and batteries
REQUIRED TOOLS
1. Medium sized Phillips screwdriver
2. Tape measure or ruler
3. Knife or scissors
4. Saw (in the event that the window sliders need to
be cut to size)
ON/OFF
TEMP
S
H
C
O
U
R
T
T
T
I
O
M
N
ER
T
I
O
M
F
E
F
R
MOD E
FAN
LED
SLEEP
SWING
1
2
3
4
5
6
7
8
9
10
11
12
13
IMPORTANT WARNING
Do not leave this appliance unattended
in a space where people or animals who
cannot react to a malfunction are located. A
malfunction such as the exhaust hose becoming
dislocated, can cause extreme overheating or
death in an enclosed, unattended space.
8
INSTALLATION INSTRUCTIONS
INSTALLING THE WINDOW KIT
The instructions below can be used for either a hung
window or a sliding window application.
1. Measure the window opening where the window
kit will be installed. Assemble as many sliders
as necessary to fi t the window. If the window
opening is less than the minimum length of a
single slider, use the slider that has the hole in it
and cut it to the correct length. Make sure not to
cut the end that has the hole as this is necessary
to attach the exhaust hose adapter. Cut the
adhesive foam seals to the correct length for the
window and attach them to the window sash
and frame.
2. Connect the window slider adapter to the
window slider by gently pressing it into the hole
in the slider until it clicks into place.
3. Attach the exhaust hose to the window slider
adapter by gently pressing it into the adapter
until it clicks into place.
4. Install the slider kit and hose assembly and close
the window to hold it in place.
5. Attach the air outlet adapter to the back of the
appliance by sliding it down into the channel
around the air outlet. Attach the hose to the air
outlet adapter on the back of the appliance by
gently pressing it into the adapter until it clicks
into place.
6. Cut the non-adhesive foam seal to match the
width of the window and insert it between the
glass and the window frame to prevent air and
insects from getting into the room.
7. Install the security bracket in the window frame
with the provided screws.
A
B
A
B
1
2
3
4
5
6
7
Note: Do not over extend or bend the hose as this
will impede air fl ow.
9
FEATURES
Front
1. Control panel
2. Horizontal louver
3. Casters
Rear
1. Upper air fi lter and air intake
2. Handles
3. Continuous drain outlet
4. Air outlet
5. Lower air fi lter and air intake
6. Power cord buckle
7. Lower drain outlet
LOCATION
Place the air conditioner on a smooth, level fl oor
that is strong enough to support it and all included
accessories.
Make sure the appliance is level to minimize noise
and vibration.
The appliance must be installed near a grounded
receptacle and the overfl ow drain outlet on the rear
of the appliance must be accessible.
Do not cover air inlets or outlets or the remote
control receiver on the control panel.
The appliance requires 50 cm (20 inches) of
clearance on the front and sides.
The appliance requires at least 50 cm (20 inches) of
clearance on the back.
INSTALLATION INSTRUCTIONS
1
2
3
1
2
3
4
5
6
7
OPERATING INSTRUCTIONS
10
3sec
3sec
1
2
3 4
5
6
7
8
CONTROL PANEL
1. Swing button: Press to start the auto swing
feature. When auto swing is activated, press
again to stop the louver at the desired angle.
2. Sleep and fi lter button:
Press to start the sleep feature.
• The lter light will illuminate after 250 hours of
use as a reminder to clean the fi lter; to reset the
lter after cleaning, press and hold the sleep
button for three seconds.
3. Timer button: Press to start the automatic timer.
Light will indicate whether a timer is set.
4. Fan button:
Press to select fan speed. Light will indicate
current speed.
Press and hold for 3 seconds to turn the
continuous fan on or off.
5. Mode button: Press to select the desired mode.
Light will indicate current mode.
6. LED display:
Shows the set temperature in °C or °F.
Shows the timer settings.
While on dry and fan mode, shows the room
temperature.
7. Temperature control buttons:
Used to set the temperature.
Press and hold both temperature control buttons
for three seconds to change the temperature
display from °C to °F.
8. Power button: Press to turn the appliance on or
off.
OPERATING MODES
Cool Mode
Choose cool mode to set the cooling function.
Use the temperature control buttons to choose
the desired temperature.
Use the fan button to choose the desired fan
speed.
The temperature can be set within a range of 17
- 30°C (62 - 86°F).
The exhaust hose should be installed during cool
mode to ensure the best results.
Dry Mode
Choose dry mode to remove excess moisture from
the air. Water will condense inside the appliance
and drain out the back.
The humidity level and fan speed will be
automatically set and cannot be modifi ed in dry
mode.
The exhaust hose does not need to be installed
during dry mode.
It may be necessary to install the continuous
drain hose during dry mode to remove excess
water.
Fan Mode
Fan mode can be used to run the fan without
engaging the cooling or dehumidifying functions.
Press the fan button to choose the desired fan
speed.
The exhaust hose does not need to be installed
during fan mode.
In cooling or dry mode, press and hold the
fan button for 3 seconds to set the fan to run
continuously. Press and hold the fan button for 3
seconds to disengage the continuous fan. During
normal operation the fan will turn on and off
with the compressor.
Auto Mode
Auto mode is a pre-set factory program that
automatically defi nes the mode (cool or fan) and
fan speed based on the set temperature and the
ambient temperature. The exhaust hose should be
installed during dry mode.
OPERATING INSTRUCTIONS
11
FOLLOW ME
There is a temperature sensor built into the remote
control that will continuously collect the current
room temperature. Keep the remote control with
you and the appliance will automatically adjust the
set temperature based on the current temperature
where you are located to reach the most
comfortable condition and temperature.
Press the follow me button to activate the follow
me function. The remote will display the current
temperature at its location. The remote will send
a signal to the air conditioner every 3 minutes, so
long as you remain within range of the appliance.
The follow me light on the control panel of the
appliance will illuminate for 5 seconds every three
minutes to indicate that it has received a signal
from the remote. If the appliance does not receive a
signal from the remote during any 7 minute interval,
it will beep to indicate that the follow me mode has
ended.
The maximum distance for the follow me feature is
8 meters (26 feet). This feature is available in cool
and auto modes.
SLEEP
The sleep function can be used to conserve energy
during sleeping hours.
When selected, the set temperature will increase
by 1°C/2°F every half hour for one full hour. The
appliance will hold the new set temperature for
6 hours before automatically returning to normal
operation.
The sleep function can be canceled at any time by
pressing the sleep button.
TIMER
Auto Off
1. When the air conditioner is turned on, press the
timer button to activate the auto off timer.
2. Press the temperature control buttons to change
the set time in 0.5 hour increments up to 10
hours and then in 1 hour increments up to 24
hours.
Auto On
1. When the air conditioner is turned off, press the
timer button to activate the auto on timer.
2. Press the temperature control buttons to change
the set time in 0.5 hour increments up to 10
hours and then in 1 hour increments up to 24
hours.
Using Auto On and Auto Off Together
The auto on and auto off timers can be used at the
same time by fi rst setting one and then the other.
For example, if the air conditioner is running,
you can set the auto off timer to let it run for a set
amount of time before turning off and then set the
auto on timer to turn it back on at a later time.
Or, if the air conditioner is not running, you can set
the auto on timer to turn it on at a later time and
then set the auto off timer to shut it off after running
for a period of time.
Note: The timer will not cycle the air conditioner on
and off indefi nitely. The auto on and auto off timers
will function one time and then the air conditioner
will return to regular functioning.
Turning the air conditioner on or off at any time
or changing the timer setting to 0.0 will cancel the
timer settings.
OPERATING INSTRUCTIONS
12
REMOTE CONTROL
1. Power button: Press to turn the appliance on or
off.
2. Mode button: Press to select the desired mode.
3. Fan button: Press to select fan speed.
4. Sleep button: Press to start the sleep feature.
5. Swing button: Press to start the auto swing
feature. When auto swing is activated, press
again to stop the louver at the desired angle.
6. Follow me button: Press to activate the follow
me feature.
7. LED button: Press to turn the LED display on or
off.
8. Timer off button: Press to set the automatic off
timer.
9. Timer on button: Press to set the automatic on
timer.
10. Shor tcut button: Press to set and activate the
short cut function.
11. Temperature control buttons:
Used to set the temperature.
Press and hold both temperature control buttons
for 3 seconds to change the temperature display
from °C to °F.
12. LED display: Shows the set temperature in °C or
°F or the auto-timer settings.
1
2
3
4 5
6 7
8
9
10
11
12
Shortcut function (only available on remote):
Used to save a favourite setting.
Set the appliance to the temperature and fan
speed that you would like to set as a favourite.
Press and hold the shortcut button for 2 seconds.
Press the shortcut button at any point in future to
return to the favourite setting.
If no favourite is set, pressing the shortcut button
will cause the appliance to run in auto mode at
29°C (79°F), with fan speed set to auto.
OPERATING INSTRUCTIONS
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference in a residential
installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation.
If this equipment does cause harmful interference
to radio or television reception, which can be
determined by turning the equipment off and on, the
user is encouraged to try to correct the interference
by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Increase the separation between the equipment
and receiver
3. Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected
4. Consult the dealer or an experienced radio/TV
technician for help
Changes or modifi cations not approved by the
party responsible for FCC compliance could void
the user’s authority to operate the equipment. This
appliance complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This device complies with Canadian CAN ICES-3
(B) / NMB-3 (B)
REPLACING THE REMOTE BATTERIES
This air conditioner comes with two AAA batteries.
Place the batteries in the remote control before use.
1. Slide the back cover from the remote downward
to expose the battery compartment.
2. Insert the batteries, ensure to match the (+) and
(-) symbols on the ends of the batteries with the
symbols inside the battery compartment.
3. Slide the battery cover back into place.
Notes:
The air conditioner will not respond if curtains,
doors or other materials block the signal from
the remote control to the unit.
Prevent any liquid from contact with the remote
control. Do not expose the remote control to
direct sunlight or heat.
If the infrared signal receiver on the indoor unit
is exposed to direct sunlight, the air conditioner
may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
Do not mix old and new batteries or batteries of
different types.
Do not leave the batteries in the remote control
if it is not going to be used for more than 2
months.
13
IMPORTANT
Do not dispose of batteries as unsorted municipal
waste. Refer to local laws for proper disposal of
batteries.
OPERATING INSTRUCTIONS
14
WATER DRAINAGE
When the internal drain pan becomes full the appliance will
beep 8 times and the digital display will show error code P1.
The air conditioning or dehumidifying action will stop but the
fan may continue to operate.
There are two methods to drain water from the appliance.
1. Drain Plug
1. Turn the appliance off and unplug it from the power source.
2. Carefully move the appliance to a location where the water
can be drained.
3. Remove the drain plug and allow the water to completely
drain.
4. Replace the bottom drain plug, pressing fi rmly to ensure a
tight fi t and no leaks.
5. The P1 error symbol will disappear and the appliance will
resume regular function once power is restored.
2. Continuous Drain
During the dry mode, you may wish to set up the continuous
drain option so that the appliance will automatically drain
collected water.
Remove the exhaust hose during dry mode, it is not necessary.
Ensure that the appliance is turned off and unplugged from the
power source before setting up the drain hose.
Remove the upper drain plug and attach the drain hose that
was provided with the appliance. Ensure that there are no
kinks or bends in the drain hose as this can stop water from
draining.
Place the open end of the drain hose over the receptacle that
the appliance will drain into; this could be a basement fl oor
drain, a sink or similar.
Remember that there is no drain pump in this appliance, the
continuous drain is activated by gravity only. Ensure that the
drain hose goes straight down toward the fl oor from the drain
connection. If the hose is not positioned directly downwards,
water will not drain correctly.
1
2
CARE & MAINTENANCE
CLEANING
Unplug the appliance before cleaning or
servicing.
Clean the cabinet with a lukewarm damp cloth
and neutral detergent. Dry the cabinet with a
lint-free dry cloth.
Do not use gasoline, paint thinner or other
chemicals to clean the appliance.
Do not wash the appliance directly under a tap
or using a hose. It may cause electrical damage.
AIR FILTER
There are three air fi lters in this appliance. Air
lters should be cleaned every two weeks to ensure
effi cient performance.
In households with animals, the air fi lters may need
to be cleaned more often and the external grills may
need to be wiped to prevent blocked air fl ow.
1
2
3
LONG-TERM STORAGE
1. Drain all water from the appliance.
2. Run the appliance on Fan mode for half a day in
a warm room to dry the inside of the appliance
and prevent mold formation.
3. Turn off the appliance and unplug it, wrap the
cord and bundle it with tape.
4. Remove the batteries from the remote control.
5. Clean the air fi lters and reinstall them.
6. Store the appliance is a cool, dark place.
Prolonged exposure to direct sunlight or extreme
heat can shorten the lifespan of the appliance.
DISPOSAL
This appliance should not be treated as regular
household waste. Check for local regulatory
compliance regarding the approved and safe
disposal of this appliance.
ERROR CODES
E1 - room temperature sensor error
E2 - evaporator temperature sensor error
E4 - display panel communication error
E7 - signal detection error
P1 - water tray is full - attach drain hose and drain
excess water
15
16
FREQUENTLY ASKED QUESTIONS
Can I leave my AC in place through the winter?
This is not recommended.
What are the standard wattage and amps used?
Information pertaining to watts and amps can be found on the rating plate located on the side of the unit.
When should I use the exhaust hose?
The exhaust hose should be used in cool and auto modes. It is not required in fan and dry modes.
Can I use an extension cord?
No, an extension cord may not be used.
Can I extend the length of the exhaust hose?
No. The unit was designed with the length of the hose in mind and has only been tested under those
conditions. Instead use an additional fan to blow the cool air to other locations.
When should I use the drain hose?
The drain hose should be used in heat mode, dry mode or if using the continuous drain.
Where do I drain water from?
The water drains from the drainage port. If you are not using the continuous drain, the internal pan drains
from the bottom outlet.
Odors
Odour is caused by the formation of mold or mildew on internal surfaces. This can happen when there is
poor air circulation, a dirty fi lter or the air conditioner was not used for a period of time.
Ensure the fi lter is clean.
Run the unit on fan mode to remove any internal moisture.
Check for any blockages in the drain lines and ensure there are no obstructions.
Please give your unit a hard reboot. Unplug it and plug it back in after 15-20 minutes. This allows the unit
to warm and drain if there is any frost stopping draining and go back to factory settings
For odour in a unit, we suggest using an algaecide tablet. You fi rst need to turn the unit off, remove the
lower grill and fi lter from the grill at the base of the unit, and then place the tablet in base.
17
TROUBLESHOOTING
Appliance will not operate
Plug is not fully inserted into the wall outlet
Blown fuse or circuit breaker
Insuf cient cooling
• Air lter is dirty
Blocked air fl ow
Appliance size is too small for application
Noise
Inadequate support in window installation; double check that all screws are tight and the installation is
secure
Odors
Formation of mold or mildew on internal wet surfaces
Place an algaecide tablet in the base pan; ensure the appliance is unplugged, remove the upper grille
and fi lter, place the tablet in the middle water tray and replace the grille and fi lter
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an authorized service
depot. Any appliance requiring service outside the limited boundaries of “In Home Service”, will be the consumer’s
responsibility to transport at their own expense to the original point of purchase or a service depot for repair. If the
appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center, it must
be delivered to the nearest authorized Danby Service Depot by the purchaser.
Transportation charges to and from the service location are not protected by this warranty and are the
responsibility of the purchaser.
During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired
or replaced, at warrantor’s option, at no charge to the original purchaser.
Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where
service must be performed by a qualified service technician. If service is performed on the unit by anyone other
than an authorized service depot, all obligations of Danby under this warranty shall be void.
First 24 months
To obtain service
Boundaries of
in-home service
LIMITED “IN HOME” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used
under the normal operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby
Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other
contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made
or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any
warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly
excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself,
howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the
purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by
the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating
conditions (ie. extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor
application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present
the proof of purchase to our authorized service depot.
Warranty Service
In Home
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
04/17
19
Bienvenue dans la famille Danby.
Nous sommes fi ers de nos produits de qualité et nous croyons en un service fi able. Nous
vous suggérons de lire ce manuel du propriétaire avant de brancher votre nouvel appareil
car il contient des informations de fonctionnement importantes, des informations de
sécurité, des conseils de dépannage et d’entretien pour assurer la fi abilité et la longévité de
votre appareil.
Vous avez droit à la couverture de la garantie décrite dans le manuel du propriétaire fourni
avec votre nouvel appareil.
1. Veuillez noter ci-dessous les informations relatives à votre appareil. Vous devez
conserver la preuve d’achat originale pour valider et bénéfi cier des services de garantie.
2. Enregistrez votre produit en ligne et recevez une PROLONGATION DE GARANTIE
GRATUITE DE 2 MOIS après avoir rempli une enquête sur les produits, à l’adresse
www.danby.com/support/product-registration/
Besoin d’assistance?
1. Lisez votre manuel du propriétaire pour obtenir de l’aide à l’installation, au dépannage
et à la maintenance.
2. Visitez www.Danby.com pour accéder aux outils en libre-service, aux FAQ et bien plus
encore en recherchant votre numéro de modèle dans la barre de recherche.
3. Pour bénéfi cier du service client le plus rapide, veuillez remplir le formulaire Web à
l’adresse www.danby.com/support. Votre soumission ira directement à un expert de
votre appareil particulier. Nos temps de réponse moyens sont compris entre 20 minutes
et 2 heures, pendant les heures ouvrables EST.
4. Composez le 1-800-263-2629 - veuillez noter que pendant les heures de pointe, les
temps d’attente peuvent dépasser une heure.
Numéro de modèle : _______________________________________________
Numéro de serie : _________________________________________________
Date d’achat : _____________________________________________________
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Danby DPA065B6WDB-6 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à