VT-MODEM Quick Start Guide www.sixnet.com Revision 28-Feb-14
All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring
methods and in accordance with the authority having jurisdiction.
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2.
WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE
REPLACING OR WIRING UNITS.
WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED
OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
WARNING – EXPLOSION HAZARD – IN HAZARDOUS OR POTENTIALLY HAZARDOUS LOCATIONS, DO NOT
SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED. USE THE UNIT FOR INTERNAL CONNECTIONS ONLY.
Power supply “RM-PS-024-01F” and “ST-PS-024-02 to be used only with Sixnet’s recognized controllers or
equivalent
Tout pouvoir, le câblage d’entrée et de sortie (I/O) doivent être conformes aux méthodes de câblage
de Classe I, Division 2 et conformément à l’autorité compétente.
AVERTISSEMENT – RISQUE D’EXPLOSION – LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE
CLASSE I, DIVISION 2.
AVERTISSEMENT – RISQUE D’EXPLOSION – LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON
D'ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER LES MODULES.
AVERTISSEMENT – RISQUE D’AVERTISSEMENT – NE DÉBRANCHEZ PAS L’ÉQUIPEMENT PENDANT QUE LE CIRCUIT EST
DIRECT OU À MOINS QUE L’ENVIRONNEMENT SOIT CONNU POUR ÊTRE LIBRE DE CONCENTRATIONS INFLAMMABLES.
AVERTISSEMENT – RISQUE D’EXPLOSION – DANS LES ENDROITS DANGEREUX OU POTENTIELLEMENT DANGEREUX, NE PAS
SEPARER UNE PARTIE DE L'UNITE SOUS TENSION. SEULEMENT UTILISEZ L'APPAREIL POUR LES CONNEXIONS INTERNES
Alimentation “RM-PS-024-01F” et “ST-PS-024-02” doit être utilisé uniquement avec les contrôleurs reconnus
par Sixnet ou leurs équivalents.
1. Carefully remove the modem and modem serial cable from the shipping container and inspect for damage.
Contact Red Lion immediately if any damage is discovered.
2. For DIN rail mounting, hook the top, rear of the modem onto the top edge of the DIN rail. Using a small flat head
screwdriver, pull down on the spring-loaded tab on the bottom of the modem and push the modem back against
the rail. Reverse these steps to remove the modem.
3. The modem can also be mounted to a flat panel using the mounting holes and #6 or #8 screws. The mounting
hole orientation and dimensions are shown in the front view figure below. The modem can be installed in any
orientation, directly adjacent to other DIN rail components or in any convenient location within the enclosure.
The modem should be installed within 6 feet of the device it will be connected to.
VT-MODEM
Installation & Operating Instructions
(Quick Start Guide)