Radar Sensoren
Radar sensors
Détecteurs à radar
Radar Distanz messende Sensoren
Radar distance measuring sensors
Détecteurs de mesure de distances
Technische Daten Technical data Données techniques
Erfassungsbereich Sd 0,5 ... 60 m sensing distance Sd 0,5 ... 60 m Portée de détection Sd 0,5 ... 60 m
Temperaturdrift < ± 10 mm temperature drift < ± 10 mm Dérive en température < ± 10 mm
Betriebsspannungsbereich
+Vs 2)
12 ... 30 VDC voltage supply range
+Vs 2)
12 ... 30 VDC Plage de tension +Vs 2) 12 ... 30 VDC
Stromaufnahme max.
(ohne Last)
220 mA current consumption
max. (no load)
220 mA Consommation max. (sans
charge)
220 mA
Ausgangsstrom < 100mA output current < 100mA Courant de sortie < 100mA
Ausgangsschaltung Stromausgang /
Gegentakt
output circuit current output / push-
pull
Circuit de sortie Sortie de courant /
push-pull
Kurzschlussfest ja short circuit protection yes Protégé contre courts-cir-
cuits
oui
Verpolungsfest ja, Vs zu GND reverse polarity pro-
tection
yes, Vs to GND Protégé contre inversion
polarité
oui, Vs vers GND
Arbeitstemperatur -40 ... +65 °C operating temperature -40 ... +65 °C Température de fonctionne-
ment
-40 ... +65 °C
Lagertemperatur -40 ... +85 °C storage temperature -40 ... +85 °C Température de stockage -40 ... +85 °C
Schutzart IP 68/69K & proTect+ protection class IP 68/69K & proTect+ Classe de protection IP 68/69K & proTect+
RR30.DAO0-11221321
Abmessungen Dimensions Dimensions Elektrischer Anschluss Connection diagram Schéma de raccordement
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
BN = Braun/brown/brun
BK = Schwarz/black/noi
WH = Weiss/white/blanc
BU = Blau/blue/bleu
GY = Grau/gray/gris
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Class 2, UL 1310, siehe / see / voir au FAQ
2) mit / with / avec IO-Link 18 ... 28VDC
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTICE: Changes or modications made to this equipment not expressly approved by Baumer may void the FCC authorization
to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not in-
stalled and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Radiofrequency radiation exposure Information: This equipment complies with FCC exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Canada Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two condi-
tions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. This equipment complies with IC radiation exposure limits set forth for an un-
controlled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator
and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme aux CNR d‘Industrie Canada applicables aux appareils radio exempts de licence. L‘exploita-
tion est autorisée aux deux conditions suivantes: (1) l‘appareil ne doit pas produire de brouillage, et (2) l‘appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d‘en compromettre le fonctionnement. Cet équipement
est conforme aux limites d‘exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit
être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Ce transmetteur
ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne.
50
17
ø 82
M30 x 1,5
M12 x 1
LED
ø 42
24
90
SW 36
0 V
+Vs
BU (3)
BN (1)
GY (5)
WH (2) output analog
Z
Zn.c.
output / IO-Link
BK (4)
Analog I
push pull
Z
4
output / IO-Link
output analog
0V
21
3
+VS
5 n.c.