TLV QS10-B QuickStation™ Manuel utilisateur

Taper
Manuel utilisateur
QS10 SERIES
QS10 SERIE
GAMME QS10
INSTRUCTION MANUAL
Keep this manual in a safe place for future reference
EINBAU- UND BETRIEBSANLEITUNG
Gebrauchsanleitung leicht zugänglich aufbewahren
MANUEL D UTILISATION
Conserver ce manuel dans un endroit facile d'accès
Copyright (C) 2022 by TLV CO., LTD. All rights reserved.
QS10-B/QS10-D/QS10-T/QS10-TD
STEAM TRAP STATION
KONDENSATABLEITERSTATION
POSTE DE PURGE VAPEUR
Deutsch
Français
English
Introduction
Before beginning installation, please read this manual to ensure correct usage of the product, and
keep the manual in a safe place for future reference.
The TLV QuickStation is a compact, reliable steam trap station with an all-in-one design featuring
a valve and strainer on the primary (inlet) side of the trap, and a check valve and valve on the
secondary (outlet) side.
This product is compatible with all TLV QuickTraps and is suitable for a range of applications,
such as steam mains, tracers and light processes.
For products with special specifications or with options not included in this manual, contact TLV
for instructions.
The contents of this manual are subject to change without notice.
Einführung
Bitte lesen Sie die Betriebsanleitung vor Einbau und Inbetriebnahme sorgfältig durch und be-
wahren Sie sie für späteren Gebrauch an einem leicht zugänglichen Ort auf.
Die TLV QuickStation ist eine kompakte und zuverlässige Kondensatableiterstation in einem
All-in-One-Design mit einem oder optional zwei Absperrkugelhähnen und einem Schmutzsieb auf
der Einlassseite sowie einem Rückschlagventil und einem Absperrventil auf der Auslassseite.
Dieses Produkt ist mit allen TLV QuickTraps kompatibel und eignet sich für die Entwässerung
einer Reihe von Anwendungen, wie z. B. Dampfleitungen, Begleitheizungen und einfache
Prozesse.
Wenden Sie sich an TLV für Sonderausführungen, die nicht in dieser Einbau- und Betriebs-
anleitung enthalten sind.
Wir behalten uns vor, den Inhalt dieser Betriebsanleitung ohne Ankündigung zu ändern.
Introduction
Veuillez lire attentivement ce manuel afin d’utiliser correctement le produit. Nous vous
recommandons de le garder dans un endroit sûr pour de futures consultations.
Le TLV QuickStation est un poste de purge vapeur compact et fiable, tout-en-un, comprenant une
vanne et un filtre du côté primaire (entrée) du purgeur, et un clapet anti-retour et une vanne du
côté secondaire (sortie).
Ce produit est compatible avec les différentes technologies de purgeur TLV et convient pour une
série d'applications, telles que les conduites de vapeur, le traçage et les petits process.
Pour tout produit aux spécifications particulières ou comportant des options non reprises dans ce
manuel, veuillez contacter TLV.
Le contenu de ce manuel est sujet à modifications sans préavis.
English
Deutsch
Français
1. Safety Considerations
• Read this section carefully before use and be sure to follow the instructions.
• Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
• The precautions listed in this manual are designed to ensure safety and prevent equipment
damage and personal injury. For situations that may occur as a result of erroneous handling,
three different types of cautionary items are used to indicate the degree of urgency and the
scale of potential damage and danger: DANGER, WARNING and CAUTION.
• The three types of cautionary items above are very important for safety: be sure to observe all
of them as they relate to installation, use, maintenance, and repair. Furthermore, TLV accepts
no responsibility for any accidents or damage occurring as a result of failure to observe these
precautions.
Indicates an urgent situation
which poses a threat of
death or serious injury
Indicates that there is a
potential threat of death
or serious injury
WARNING
CAUTION
WARNING
DANGER CAUTION
Indicates that there is a
possibility of injury or
equipment/product damage
DO NOT use for toxic, flammable or otherwise hazardous fluids. Use
only for fluids listed in the specification table. This product is for
intended use only. Improper use may result in such hazards as damage
to the product or malfunctions that may lead to serious accidents.
Install properly and DO NOT use this product outside the
recommended operating pressure, temperature and other
specification ranges. Improper use may result in such hazards as
damage to the product or malfunctions that may lead to serious
accidents. Local regulations may restrict the use of this product to below
the conditions quoted.
Be sure to use only the recommended components when repairing
the product, and NEVER attempt to modify the product in any way.
Failure to observe these precautions may result in damage to the
product or burns or other injury due to malfunction or the discharge of
fluids.
Take measures to prevent people from coming into direct contact
with product outlets. Failure to do so may result in burns or other injury
from the discharge of fluids.
Do not use excessive force when connecting threaded pipes to the
unit. Over-tightening may cause breakage leading to fluid discharge,
which may cause burns or other injury.
Use only under conditions in which no freeze-up will occur. Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the
product has cooled to room temperature.
Disassembling or removing the product when it is hot or under pressure
may lead to discharge of fluids, causing burns, other injuries or damage.
Use only under conditions in which no water hammer will occur.
The impact of water hammer may damage the product, leading to fluid
discharge, which may cause burns or other injury.
Do not stand on or apply body weight to the handle. The handle may
break, resulting in injury or other accident.
English
1. Sicherheitshinweise
• Bitte lesen Sie dieses Kapitel vor Beginn der Arbeiten sorgfältig durch und befolgen Sie die
Vorschriften.
• Einbau und Ausbau, Inspektion, Wartungs- und Reparaturarbeiten, Öffnen/Schließen von
Armaturen, Einstellung von Komponenten, dürfen nur von geschultem Wartungspersonal
vorgenommen werden.
• Die Sicherheitshinweise in dieser Einbau- und Betriebsanleitung dienen dazu, Unfälle,
Verletzungen, Betriebsstörungen und Beschädigungen der Anlagen zu vermeiden. Für
Gefahrensituationen, die durch falsches Handeln entstehen können, werden drei verschiedene
Warnzeichen benutzt: GEFAHR; WARNUNG; VORSICHT.
• Diese drei Warnzeichen sind wichtig für Ihre Sicherheit. Sie müssen unbedingt beachtet werden,
um den sicheren Gebrauch des Produktes zu gewährleisten und Einbau, Wartung und
Reparatur ohne Unfälle oder Schäden durchführen zu können. TLV haftet nicht für Unfälle oder
Schäden, die durch Nichtbeachtung dieser Sicherheitshinweise entstehen.
Bedeutet, dass eine
unmittelbare Gefahr für Leib
und Leben besteht.
Bedeutet, dass die
Möglichkeit der Gefahr für
Leib und Leben besteht.
VORSICHT
WARNUNG
GEFAHR
WARNUNG
VORSICHT
Bedeutet, dass die Möglichkeit
von Verletzungen oder Schäden an
Anlagen oder Produkten besteht.
Nicht für giftige, entflammbare oder anderweitig gefährliche Medien
verwenden. Produkte nicht zweckentfremdet verwenden.
Nichtbeachtung kann zu Betriebsstörungen oder Unfällen führen.
Die Einbauhinweise beachten und die spezifizierten Betriebsgrenzen
NICHT ÜBERSCHREITEN. Nichtbeachtung kann zu Betriebsstörungen
oder Unfällen führen. Örtliche Vorschriften können die Verwendung
dieses Produkts auf Bedingungen unterhalb der angegebenen
maximalen Grenzen beschränken.
Zur Reparatur sind nur Original-Ersatzteile zu verwenden; weiterhin
darf das Produkt nicht verändert werden. Nichtbeachtung kann zu
Beschädigungen des Produkts führen, die Betriebsstörungen,
Verbrennungen oder Verletzungen durch austretende Medien
verursachen.
Nur an Stellen einbauen, an denen kein Wasserschlag eintreten kann.
Wasserschlag kann das Produkt beschädigen, was zu Verbrennungen
oder Verletzungen durch austretende Medien führen kann.
Nicht auf die Handhebel stellen oder anderweitig belasten, um
Beschädigung und Unfallgefahr zu vermeiden.
Vor Öffnen des Gehäuses und Ausbau von Teilen warten, bis der
Innendruck sich auf Atmosphärendruck gesenkt hat und das
Gehäuse auf Raumtemperatur abgekühlt ist. Nichtbeachtung kann zu
Verbrennungen oder Verletzungen durch austretende Medien führen.
Treffen Sie Maßnahmen, um zu verhindern, dass Personen in
direkten Kontakt mit austretenden Medien kommen. Nichtbeachtung
kann zu Verbrennungen oder Verletzungen durch austretende Medien
führen.
Bei Schraubanschlüssen keine übermäßige Kraft anwenden, damit
die Gewinde nicht beschädigt werden. Nichtbeachtung kann zu
Beschädigungen des Produkts führen, die Betriebsstörungen,
Verbrennungen oder Verletzungen durch austretende Medien
verursachen.
Nur in frostsicherer Umgebung einsetzen. Einfrieren kann das Produkt
beschädigen, was zu Verbrennungen oder Verletzungen durch
austretende Medien führen kann.
Deutsch
1. Règles de sécurité
• Lire attentivement cette notice avant utilisation et suivre les instructions.
• Tout installation, inspection, entretien, réparation, démontage, réglage et
ouverture/fermeture de vanne doit être fait uniquement par une personne formée à l’entretien.
• La liste des précautions à prendre est établie afin d'assurer votre sécurité et de prévenir des
dégâts matériels et/ou des blessures sérieuses. Dans certaines situations causées par une
mauvaise manipulation, trois indicateurs sont utilisés afin d'indiquer le degré d'urgence,
l'échelle du dommage potentiel et le danger : DANGER, AVERTISSEMENT et ATTENTION.
• Ces 3 indicateurs sont importants pour votre sécurité ; observez les précautions de sécurité
énumérées dans ce manuel pour l'installation, l'utilisation, l'entretien et la réparation du produit.
TLV n'accepte aucune responsabilité en cas d'accident ou de dommage survenant à la suite
d'un non-respect de ces précautions.
Indique une situation
d'urgence avec risque de
mort ou de blessure grave.
Indique une situation
pouvant entraîner la mort ou
des blessures graves.
AVERTISSEMENT
ATTENTION
AVERTISSEMENT
DANGER
ATTENTION
Indique un risque de blessure
ou de dégât matériel au
produit et/ou aux installations.
Installer le produit correctement et NE PAS l’utiliser en dehors de la
pression et de la température maximales de fonctionnement, ni en dehors
des autres plages spécifiées. Une telle utilisation peut entraîner des dommages
au produit ou des dysfonctionnements, ce qui peut provoquer des accidents
graves. Il se peut que des règlements locaux limitent l'utilisation du produit en
deçà des spécifications indiquées. Il se peut que des règlements locaux limitent
l’utilisation du produit en deçà des spécifications indiquées.
NE PAS UTILISER pour des fluides toxiques, inflammables ou dangereux,
mais uniquement pour les fluides repris dans les caractéristiques
techniques. Utiliser uniquement ce produit dans le cadre de l’usage pour lequel il
est destiné. Tout usage inadapté peut causer des dégâts au produit ou des
dysfonctionnements pouvant causer de sérieux accidents.
Utiliser uniquement les pièces recommandées, et NE JAMAIS essayer de
modifier le produit de quelque manière que ce soit. Le non-respect de cette
règle peut endommager le produit ou causer des brûlures ou autres blessures
suite à des dysfonctionnements ou à l'écoulement de fluides.
Lors du démontage ou du retrait du produit, attendre que la pression
interne soit égale à la pression atmosphérique et que la surface de
l'appareil soit complètement refroidie. Le non-respect de cette règle peut
provoquer des brûlures et autres dommages dus à l'écoulement des fluides.
Ne pas utiliser de force excessive lors du raccordement du produit à la
tuyauterie. Un serrage trop fort peut provoquer la rupture du produit, entraîner
l'écoulement des fluides, et causer des brûlures ou autres blessures.
N'utiliser que dans les conditions où le gel ne se produit pas. Le gel peut
endommager le produit, provoquer l'écoulement des fluides, et causer des
brûlures ou autres blessures.
Ne vous tenez pas debout et n'appliquez pas le poids de votre corps
sur la poignée. La poignée peut se briser et entraîner des blessures ou
d'autres accidents.
Prendre les mesures appropriées afin d’éviter que des personnes
soient en contact direct avec le produit ouvert. Le non-respect de
cette règle peut provoquer des brûlures et autres blessures sérieuses
dues à l'écoulement des fluides.
N'utiliser que dans les conditions où il n'y a aucun coup du bélier.
L'impact du coup du bélier peut endommager le produit et provoquer
l'écoulement des fluides, ainsi que des brûlures ou autres blessures.
Français
2. Specifications Technische Daten Données techniques
To avoid malfunctions, product damage, accidents or serious injury, install
properly and DO NOT use this product outside the specification range. Local
regulations may restrict the use of this product to below the conditions quoted.
Die Einbauhinweise beachten und die spezifizierten Betriebsgrenzen NICHT
ÜBERSCHREITEN. Nichtbeachtung kann zu Betriebsstörungen oder Unfällen führen.
Lokale Vorschriften können zur Unterschreitung der angegebenen Werte zwingen.
VORSICHT
Installer le produit correctement et NE PAS I'utiliser en dehors des plages
spécifiées. En cas de dépassement des limites données, des dysfonc-
tionnements ou accidents pourraient survenir. Il se peut que des règlements
locaux limitent l'utilisation du produit en deçà des spécifications indiquées.
ATTENTION
CAUTION
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS.
* Maximal zulässiger Druck (PMA) und maximal zulässige Temperatur (TMA) sind
AUSLEGUNGSDATEN, NICHT BETRIEBSDATEN.
* La pression maximale admissible (PMA) et la température maximale admissible (TMA) sont des
CONDITIONS DE CONCEPTION DU CORPS, PAS DES CONDITIONS DE FONCTIONNEMENT.
A Model / Typ / Modèle
B Nominal Diameter / Größe (DN) / Dimension (DN)
C Max. Allowable Pressure* /
Max. zulässiger Druck* /
Press. maximale admissible (PMA)*
D Max. Allowable Temperature* /
Max. zulässige Temperatur* /
Temp. maximale admissible (TMA)*
E Max. Operating Temp. /
Max. zulässige Betriebstemp. /
Temp. de fonctionnement max. (TMO)
F Max. Operating Press. / Max. zulässiger Betriebsdruck / Press. de fonctionnement max. (PMO)
G
Production Lot No. /
Produktions LOT-Nr. / Lot de Production nº
A
G
D
E
C
F
B
Refer to the product nameplates on the trap unit AND on the connector body for detailed
specifications. When a trap unit is installed on a connector unit and the PMA/PMA and/or
PMO/TMO values displayed on the two nameplates differ, the specifications for the assembled
products are restricted to the lower values.
Die technischen Daten stehen auf dem Typenschild. Wenn ein Kondensatableiter an einem
Schnellanschluss montiert ist und die auf den Typenschildern angegebenen PMA/TMA- und/oder
PMO/TMO-Werte voneinander abweichen, gelten nur die Spezifikationen des montierten
Produktes mit den niedrigeren Werten.
Reportez-vous aux plaques signalétiques du produit sur le purgeur ET sur le corps du connecteur
pour des spécifications détaillées. Lorsqu'un purgeur est installé sur un connecteur et que les
valeurs PMA/PMA et/ou PMO/TMO affichées sur les deux plaques signalétiques diffèrent, les
spécifications des produits assemblés sont limitées aux valeurs les plus basses.
Do not use the ball valve with a half open position. The valve seat may be damaged.
Make sure to use the ball valve in a fully opened or closed position.
Furthermore do not use for slurry fluids.
Special products may differ from the above specifications. Refer to the drawings, etc. for details.
Verwenden Sie den Kugelhahn nicht in halb offener Stellung. Der Kugelsitz kann beschädigt werden.
Der Kugelhahn darf nur in vollständig geöffneter oder geschlossener Position betrieben werden.
Außerdem dürfen sie nicht für feststoffbeladene Fluide verwendet werden.
Spezielle Produkte können von den oben genannten Spezifikationen abweichen. Einzelheiten sind den
Zeichnungen usw. zu entnehmen.
N'utilisez pas le robinet à boisseau sphérique en position semi-ouverte. Le siège de la vanne peut être endommagé.
Veillez à utiliser le robinet à boisseau sphérique en position complètement ouverte ou fermée.
En outre, ne pas utiliser pour les fluides de type boue.
Les produits spéciaux peuvent différer des spécifications ci-dessus. Reportez-vous aux dessins, etc. pour plus de
détails.
English
Deutsch
Français
3. Configuration Aufbau Configuration
Body
Cover
Ball
Valve Seat
Body Gasket
Thrust Washer
Gland Gasket
O-ring
Gland Nut
Valve Stem
Inlet Cover Bolt
Inlet Cover Nut
Handle Nut
Spring Washer
Handle
Handle Bolt
Valve Cover Nut
Connector Body
Screen
Screen Holder Gasket
Screen Holder
Nameplate
Check Valve
Disc
Coil Spring
Spring Holder
Spacer
Outlet Cover Bolt
Part Name R C
*
*
*
*
*
M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
M = Maintenance Kit
R = Repair Kit
C = Check Valve Unit
Kugelhahn
Leitungsanschluss
Kugel
Kugelsitz
Gehäusedichtung
Druckring
Stopfbuchsdichtung
O-Ring
Stopfbuchsschraube
Ventilspindel
Schraube Einlassgehäuse
Mutter Einlassgehäuse
Handhebelmutter
Federring
Handhebel
Arretierungsschraube
Mutter Arretierungsschraube
Universal-Anschlussstück
Schmutzsieb
Dichtung Siebhaltestopfen
Siebhaltestopfen
Typenschild
Rückschlagventil
Ventilteller
Druckfeder
Schließfederhalter
Abstandshalter
Schraube Auslassgehäuse
Bauteil
M = Wartungssatz
R = Reparatursatz
C =
Rückschlagventileinheit
Corps
Couvercle
Boule
Siège de soupape
Joint de corps
Rondelle de butée
Joint du presse-étoupe
Joint torique
Écrou de serrage
Tige de vanne
Boulon du couvercle entrée
Écrou de couvercle entrée
Écrou de poignée
Rondelle de ressort
Poignée
Boulon de la poignée
Écrou de couvercle de vanne
Raccordement du corps
Crépine
Joint de porte-crépine
Porte-crépine
Plaquette nominative
Clapet anti-retour
Disque
Ressort hélicoïdal
Support du ressort
Entretoise
Boulon de couvercle sortie
Désignation
M = Kit de maintenance
R = Kit de réparation
C = Clapet anti-retour
* The check valve unit is shipped assembled.
* Das Rückschlagventil wird montiert geliefert.
* Le clapet anti-retour est expédié assemblé.
English
Deutsch
Français
4. Installation
Installation Procedures
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing
should be carried out only by trained maintenance personnel.
1. Before installing the product, blow out the inlet piping to remove any piping scraps, dirt and oil.
2. Before installation, be sure to remove all protective seals.
3. There is no restrictions on the inlet or outlet when installing the product.
4. Screwed connection type: installation of a union is recommended at both the inlet and outlet to
facilitate maintenance.
If there is a problem, determine the cause by using the “Troubleshooting” section in this manual.
Installation Orientation
1. Install the product so the arrow on the body is pointing in the direction of condensate flow.
2.
For horizontal piping, install the product so that the surface of the handle is parallel to the ground.
There is no restriction on the installation orientation for horizontal piping as long as the
direction of flow and the arrow on the connection body are aligned.
Vertical PipingHorizontal Piping Horizontal Piping
WARNING
DO NOT use for toxic, flammable or otherwise hazardous fluids. Use only
for fluids listed in the specification table. This product is for intended use
only.
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
• Take measures to prevent people from coming into direct contact with
product outlets.
Do not use excessive force when connecting threaded pipes to the unit.
• Do not stand on or apply body weight to the handle.
CAUTION
Ground
English
2
3
1
1
2
5. Maintenance
Tightening the gland section
The valve gland can be tightened. If leaks from the gasket or the sealing portion continue, tighten
as shown in the following steps.
1. Loosen the handle nut to remove the handle.
(To remove the valve section, refer to "Disassembly/Reassembly of the Valve Section" in the
"Disassembly/Reassembly" section.)
2. Tighten the gland nut with a socket wrench
Notes on retightening:
• Do not tighten the gland nut all at once, and do not tighten it further once the leak has stopped.
• If a leak continues after retightening the gland nut, replace it with a new one.
1
2
3
Socket
Handle
Handle Nut
1
2
Socket
Gland Nut
When disassembling or removing the product, wait until the internal pressure
equals atmospheric pressure and the surface of the product has cooled to
room temperature.
Be sure to use only the recommended components when repairing the
product, and NEVER attempt to modify the product in any way.
CAUTION
English
Disassembly/Reassembly of the Check Valve Section
This section cannot be disassembled or reassembled as a special tool is required. For this
reason, repair parts are not provided.
6. Disassembly/Reassembly
Disassembly/Reassembly of the Valve Section
NOTE: - Coat all threaded portions with anti-seize.
- If drawings or other special documentation were supplied for the product, any torque
given there takes precedence over values shown here.
Use the following procedures to remove components. Use the same procedures in reverse to
reassemble. (Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.)
Part Name & No. Disassembly Reassembly
Handle Nut 13 Remove with a socket wrench Consult the table of tightening
torques and tighten to the
proper torque
Spring Washer 14 Remove the spring washer Reattach the spring washer
Handle 15 Remove the handle Reattach the handle
Gland Nut 9 Remove with a socket wrench Coat threaded portions with
anti-seize (e.g. Molykote)
Consult the table of tightening
torques and tighten to the
proper torque
Disassembly/Reassembly of the Connector Body Section
Table of Tightening Torques
Part Name & No. Disassembly Reassembly
Screen Holder 21 Remove with a socket wrench Coat threaded portions with
anti-seize (e.g. Molykote)
Screen Holder Gasket
20 Remove the gasket and clean
sealing surfaces Replace with a new gasket
Screen 19 Remove without bending Insert without bending
Part Name & No. Torque Distance Across Flats
Handle Nut 13
Gland Nut 9
Screen Holder 21
Inlet Cover Nut 12
30
30
100
30
(22)
(22)
(73)
(22)
(lbf·ft)
13
16
30
13
mm
( )
( )
( )
( )
(in)
Valve Seat 4 Remove the valve seat Replace with a new valve seat
Body Gasket 5 Remove the gasket and clean
sealing surfaces Replace with a new gasket
Ball 3 Remove the ball Insert the ball
Valve Stem 10 Remove the valve stem Insert the valve stem
(1 N·m 10 kg·cm)
• Take measures to prevent people from coming into direct contact with
product outlets.
• Be sure to use only the recommended components when repairing the
product, and NEVER attempt to modify the product in any way.
CAUTION
N·m
2
1
/
8
5
/
2
1
/
16
3
/
1
English
Exploded View
Valve Section
When installing the valve seat, pay attention to its
orientation. Install the valve seat with the large
chamfered side facing the ball.
Installation orientation of the valve seat
Connector Body Section
Part Name Part Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Body
Cover
Ball
Valve Seat
Body Gasket
Thrust Washer*
Gland Gasket*
O-ring*
Gland Nut
Valve Stem
Inlet Cover Bolt
Cover Nut (Inlet/Outlet)
Handle Nut
Spring Washer
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Handle
Handle Bolt
Valve Cover Nut
Connector Body
Screen
Screen Holder Gasket
Screen Holder
Nameplate*
Check Valve
Disc*
Coil Spring*
Spring Holder*
Spacer
Outlet Cover Bolt
*Not Shown
No. No.
17
16
13
14
15
9
3
10
45
54
1
18
19
20
21
12
12
2
1
1
27 2
23
18
14
14
11
28
English
7.
Instructions for Plug/Holder Disassembly and Reassembly
The seal on the threaded plugs/holders found on TLV products is formed by a flat metal gasket.
There are various installation orientations for the gaskets, such as horizontal, diagonal and
downward, and the gasket may be pinched in the thread recesses during assembly.
1. Remove the plug/holder using a tool of the specified size (distance across flats).
2. The gasket should not be reused. Be sure to replace it with a new gasket.
3. Clean the gasket surfaces of the plug/holder and the product body using a rag and/or cleaning
agents, then check to make sure the surfaces are not scratched or deformed.
4. Coat both the gasket surface of the plug/holder and the threads of the plug/holder with
anti-seize, then press the gasket onto the center of the gasket surface of the plug/holder,
making sure the anti-seize affixes the gasket tightly to the plug/holder. Check to make sure the
gasket is not caught in the recesses of the threads.
5. Hold the plug/holder upside down to make sure that the anti-seize makes the gasket stick to
the plug/holder even when the plug/holder is held upside down.
6. Screw the plug/holder by hand into the product body while making sure that the gasket
remains tightly affixed to the center of the gasket surface of the plug/holder. Make sure the
entire gasket is making contact with the gasket surface of the product body. It is important at
this point to make sure the gasket is not pinched in the thread recesses of the plug/holder.
7. Tighten the plug/holder to the proper torque.
8. Next, begin the supply of steam and check to make sure there is no leakage from the part just
tightened. If there is leakage, immediately close the inlet valve and, if there is a bypass valve,
take the necessary steps to release any residual pressure. After the surface of the product
cools to room temperature, repeat the procedure beginning from step 1.
Instructions for Disassembly and Reassembly
English
8. Troubleshooting
When the product fails to operate properly, use the following table to locate the cause and
remedy.
Problem RemedyCause
Fluid leaks
from the outlet
side
The valve sealing section is clogged with rust or
scale, or the O-ring is scratched or damaged Clean or replace with new
parts
Fluid leaks
from the gland
section
Sealing surfaces and/or gaskets are clogged
with rust or scale, damaged or worn Tighten, clean or replace
with new parts
The valve does
not move or
remained half
open
The valve seat and the ball are clogged with rust
or scale, or the valve seat is deformed Clean or replace with a new
valve
The handle is worn or deformed Replace with a new handle
Fluid leaks
from where the
inlet cover is
assembled
Gasket deterioration or damage Replace with new gasket(s)
The valve seat
is damaged Water hammer has occurred Check whether there is a
problem with the piping.
The cover nut is not properly tightened Tighten it to the proper
torque
The product is being used with the valve(s) half
open Use the product with the
valves fully opened or fully
closed.
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product has
cooled to room temperature.
CAUTION
English
9. Options
Configuration
With Blowdown Valve TLV-BD2N (Horizontal)/BD2V (Vertical)
2
3
1 6
5
4
BD2N (Horizontal)
2
3
4
1
5
6
BD2V (Vertical)
1
2
3
4
5
6
BD2 Valve
BD2 Valve Seat (Screen Holder)
Screen Holder Gasket
Screen
Valve Stopper Pin
Discharge Hole
Part Name
No.
• Always wear eye protection and heat-resistant gloves when operating the
blowdown valve.
• When operating the blowdown valve, stand to the side well clear of the
outlet to avoid contact with internal fluids that will be discharged.
Operate the valve slowly and surely, taking care to avoid the area from
which internal fluids are discharged and any fluids deflected off piping or
the ground etc.
• Do not tighten the BD2 valve or the BD2 valve seat in excess of the
appropriate tightening torque.
• Do not excessively loosen the BD2 valve when opening the blowdown
valve.
CAUTION
English
TLV Blowdown Valve: BD2
The BD2 blowdown valve, installed in the screen area of the connector body, uses the trap’s
internal pressure to blow any condensate, steam, dirt or scale accumulated around the screen
area out to atmosphere.
BD2N (Horizontal)
Installation Orientation
When installing the blowdown valve, make sure that the discharge hole is facing towards the
ground.
Correct Incorrect (The blowdown hole not facing the ground)
BD2V (Vertical)
Correct Incorrect (The blowdown hole not facing the ground)
Ground Ground
Ground Ground
English
Operating Instructions for BD2 Blowdown Valve
1. The BD2 valve is in the closed position when the BD2 is shipped from the factory. Before
attempting to operate the BD2, reconfirm that the BD2 valve is still in the closed position.
Locate the blow outlet and, during operation, stand to the side and well clear of it, as the jet of
condensate or steam could cause burns.
2. Remain in the area the entire time the BD2 valve is in the open position. Before opening the
BD2 valve, grip the BD2 valve seat with a wrench and hold firmly in place so that it will not
rotate when the BD2 valve is loosened. Grip the BD2 valve with another wrench and slowly
loosen. Condensate and steam will discharge from the blow outlet in a jet stream. Be careful
not to loosen the BD2 valve so far that it becomes removed from the BD2 valve seat. (If the
valve stopper pin becomes damaged, large quantities of steam will be discharged in a jet
stream.)
3. Close the BD2 valve until the flow of fluid completely stops. If the flow of fluid does not stop,
re-open the BD2 valve (as in step “2”) to blow out any scale or dirt that may be caught in the
BD2. Re-tighten the BD2 valve until the flow of fluid stops completely.
NOTE: Avoid the use of excessive tightening torques,
as threaded parts may become damaged.
Part Name Torque
Tightening Torques and Distance Across Flats
Distance Across Flats
BD2 Valve 1
BD2 Valve Seat (Screen Holder) 2
30
100
(22)
(73)
17
30
( )
( )
N·m (lbf·ft) mm (in)
(1 N·m 10 kg·cm)
32
21
/
16
3
/
1
English
4. Einbau
Einbauhinweise
Ein- und Ausbau, Inspektion, Wartungs- und Reparaturarbeiten, Öffnen/Schließen von Armaturen
und Einstellung von Komponenten dürfen nur von geschultem Wartungspersonal vorgenommen
werden.
1. Bevor Sie das Produkt montieren, blasen Sie die Rohrleitung aus, um Öl und Verschmutzungen
zu entfernen.
2. Achten Sie vor der Installation darauf, alle Schutzkappen zu entfernen.
3. Bei der Installation des Produkts gibt es keine Einschränkungen hinsichtlich des Ein- oder
Auslasses.
4. Schraubverbindung: Es wird empfohlen, sowohl am Ein- als auch am Auslass eine
Verschraubung anzubringen, um die Wartung zu erleichtern.
Zur Ursachenbestimmung bei Problemen während des Betriebs siehe Absatz „Fehlersuche“.
Einbaulage
1. Installieren Sie das Produkt so, dass der Pfeil auf dem Gehäuse in Durchflussrichtung des
Kondensats zeigt.
2.
Bei horizontalen Rohrleitungen ist das Produkt so zu installieren, dass der Schwenkbereich des
Handhebels parallel zum Boden verläuft.
Bei horizontaler Installation gibt es keine Einschränkungen hinsichtlich der Einbaulage, solange
die Durchflussrichtung und der Pfeil auf dem Anschlussstück übereinstimmen.
Vertikale RohrleitungHorizontale Rohrleitung Horizontale Rohrleitung
Nicht für giftige, entflammbare oder anderweitig gefährliche Medien
verwenden. Produkte nicht zweckentfremdet verwenden.
Die Einbauhinweise beachten und die spezifizierten Betriebsgrenzen NICHT
ÜBERSCHREITEN.
• Treffen Sie Maßnahmen, um zu verhindern, dass Personen in direkten
Kontakt mit austretenden Medien kommen.
Bei Schraubanschlüssen keine übermäßige Kraft anwenden, damit die
Gewinde nicht beschädigt werden.
• Nicht auf die Handhebel stellen oder anderweitig belasten.
Boden
VORSICHT
WARNUNG
Deutsch
2
3
1
1
2
5. Wartung
Nachstellen der Stopfbuchsdichtung
Die Stopfbuchse des Kugelhahns kann nachgezogen werden, wenn die Dichtung oder der
Dichtungsbereich undicht sind. Gehen Sie wie folgt vor:
1. Lösen Sie die Mutter (3) des Handhebels (2) mit Hilfe eines Steckschlüssels (1), um den
Handhebel abzunehmen.
(Zum Ausbau des Ventilkörpers siehe "Demontage/Montage des Ventilkörpers" im Abschnitt
"Demontage/Montage".)
2. Ziehen Sie die Stopfbuchsschraube (2) mit einem Steckschlüssel (1) an.
Hinweise zum Nachziehen:
• Ziehen Sie die Stopfbuchsmutter nicht in einem Schritt komplett an;, und ziehen Sie sie nicht
weiter an, wenn die Leckage gestoppt ist.
• Wenn die Leckage nach dem Anziehen der Stopfbuchsmutter anhält, ersetzen Sie sie die
Dichtungspackung.
1
2
3
Muffe
Handhebel
Handhebelmutter
1
2
Muffe
Stopfbuchsschraube
Vor Öffnen des Gehäuses und Ausbau von Teilen warten, bis der Innendruck
sich auf Atmosphärendruck gesenkt hat und das Gehäuse auf
Raumtemperatur abgekühlt ist.
Zur Reparatur sind nur Original-Ersatzteile zu verwenden; weiterhin darf das
Produkt nicht verändert werden.
VORSICHT
Deutsch
Demontage/Montage des Rückschlagventils
Dieses Bauteil kann nicht zerlegt oder wieder zusammengebaut werden, da dafür ein
Spezialwerkzeug erforderlich ist. Aus diesem Grund werden auch keine Ersatzteile mitgeliefert.
6. Demontage/Montage
Demontage/Montage des Kugelhahns
NOTE: - Bestreichen Sie alle Gewindeteile mit Schmiermittel.
- Falls andere spezielle Dokumente mit dem Produkt geliefert wurden, haben Angaben
über Anzugsmomente in diesen Unterlagen Vorrang vor den hier gezeigten
Anzugsmomenten.
Es folgen die Arbeitsschritte um Komponenten auszubauen. Der Zusammenbau erfolgt in
umgekehrter Reihenfolge. (Einbau und Ausbau, Inspektion, Wartungs- und Reparaturarbeiten,
Öffnen/Schließen von Armaturen, Einstellung von Komponenten, dürfen nur von geschultem
Wartungspersonal vorgenommen werden.)
Bauteil Während Demontage Während Montage
Handhebelmutter 13 Mit Steckschlüssel entfernen Entsprechend der Tabelle für
Anzugsmomente anziehen
Federring 14 Federring entfernen Federring wieder anbringen
Handhebel 15 Handhebel entfernen Handhebel wieder anbringen
Stopfbuchsschraube 9 Mit Sechskantschlüssel entfernen Alle Gewinde mit Schmiermittel
(z.B. Molykote) bestrichen.
Entsprechend der Tabelle für
Anzugsmomente anziehen
Demontage/Montage des Anschlussgehäuses
Tabelle für Anzugsmomente und Schlüsselweiten
Bauteil Während Demontage Während Montage
Siebhaltestopfen 21 Mit Sechskantschlüssel entfernen Alle Gewinde mit Schmiermittel
(z.B. Molykote) bestrichen.
Siebhaltestopfen-
Dichtung 20 Dichtung entfernen und
Dichtflächen reinigen Dichtung ersetzen
Schmutzsieb 19 Herausnehmen, nicht verbiegen Einsetzen ohne zu verbiegen
Bauteil Anzugsmoment Schlüsselweite
Handhebelmutter 13
Stopfbuchsschraube 9
Siebhaltestopfen 21
Mutter Einlassgehäuse 12
30
30
100
30
13
16
30
13
mm
Kugelsitz 4 Kugelsitz ausbauen Neuen Kugelsitz verwenden
Gehäusedichtung 5 Dichtung entfernen und
Dichtflächen reinigen Gehäusedichtung ersetzen
Kugel 3 Kugel entfernen Kugel einsetzen
Ventilspindel 10 Ventilteller ausbauen Ventilteller einbauen
(1 N·m 10 kg·cm)
• Treffen Sie Maßnahmen, um zu verhindern, dass Personen in direkten
Kontakt mit austretenden Medien kommen.
• Zur Reparatur sind nur Original-Ersatzteile zu verwenden; weiterhin darf
das Produkt nicht verändert werden.
N·m
VORSICHT
Deutsch
Übersicht Einzelteile
Kugelhahn
Achten Sie beim Einbau des Kugelsitzes auf seine
Ausrichtung. Bauen Sie den Kugelsitz so ein, dass
die große abgeschrägte Seite zur Kugel zeigt.
Einbaulage des Kugelsitzes
Universal-Anschlussstück
Bauteil Bauteil
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Kugelhahn
Leitungsanschluss
Kugel
Kugelsitz
Gehäusedichtung
Druckring*
Stopfbuchsdichtung*
O-Ring*
Stopfbuchsschraube
Ventilspindel
Schraube Einlassgehäuse
Gehäusemutter (Einlass/Auslass)
Handhebelmutter
Federring
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Handhebel
Handhebelschraube
Mutter Einlass-Gehäusedeckel
Universal-Anschlussstück
Schmutzsieb
Dichtung Siebhaltestopfen
Siebhaltestopfen
Typenschild*
Rückschlagventil
Ventilteller*
Feder*
Federsitz*
Abstandshalter
Schraube Auslassgehäuse
*Nicht dargestellt
Nr. Nr.
17
16
13
14
15
9
3
10
45
54
1
18
19
20
21
12
12
2
1
1
27 2
23
18
14
14
11
28
Deutsch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

TLV QS10-B QuickStation™ Manuel utilisateur

Taper
Manuel utilisateur