Ryobi P739-PCL204KN Le manuel du propriétaire

Catégorie
Compresseurs d'air
Taper
Le manuel du propriétaire
OPERATOR’S MANUAL
MANUEL D’UTILISATION
MANUAL DEL OPERADOR
1 GALLON 18 VOLT
AIR COMPRESSOR
COMPRESSEUR D’AIR
18 V DE 3,8 L (1 GAL)
COMPRESOR DE AIRE
DE 18 V DE 3,8 L (1 GAL.)
P739
SAVE THIS MANUAL FOR
FUTURE REFERENCE
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL
PARA FUTURAS CONSULTAS
TABLE OF CONTENTS
****************
General Safety Rules .......................... 3
Specific Safety Rules ......................4-5
Symbols ...........................................6-7
Glossary of Terms ...............................7
Features ..............................................8
Assembly ............................................ 8
Operation .......................................8-11
Maintenance ..................................... 11
Troubleshooting ................................ 12
Illustrations ..................................13-14
Parts Ordering/Service ....... Back Page
TABLE DES MATIÈRES
****************
Règles de sécurité générales .............3
Règles de sécurité particulières ......4-5
Symboles .........................................6-7
Glossaire .............................................7
Caractéristiques .................................8
Assemblage ........................................8
Utilisation .......................................8-11
Entretien ...........................................11
Dépannage .......................................12
Illustrations ..................................13-14
Commande de pièces/
réparation ..........................Page arrière
ÍNDICE DE CONTENIDO
****************
Reglas de seguridad generales .......... 3
Reglas de seguridad específicas ....4-5
Símbolos .........................................6-7
Glosario de términos ..........................7
Características ...................................8
Armado ............................................... 8
Funcionamiento .............................8-11
Mantenimiento ..................................11
Solución de problemas ....................12
Ilustraciones ................................13-14
Pedidos de piezas/
servicio .......................... Pág. posterior
WARNING: To reduce the
risk of injury, the user must read and
understand the operator’s manual
before using this product.
ADVERTENCIA: Para reducir
el riesgo de lesiones, el usuario debe leer
y comprender el manual del operador
antes de usar este producto.
AVERTISSEMENT :
Pour
réduire les risques de blessures,
l’utilisateur doit lire et veiller à bien
comprendre le manuel d’utilisation avant
d’employer ce produit.
30 30
35
21
1
60
90
90
120
60
120
DANGER:
This compressor/pump is not equipped and should not be used to supply breathing quality air. Additional equip-
ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing
as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.134.
Compressed Gas Association, 4221 Walney Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700,
www.cganet.com. Any such additional equipment has not been examined and no implication of proper use for breathing
air is intended or implied.
If this compressor is altered in any way, existing warranties shall be voided. RYOBI and One World Technologies, Inc.,
disclaim any liabilities whatsoever for any loss, personal injury, or damage.
DISCLAIMER OF WARRANTIES
In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equip-
ment is not simultaneously used, existing warranties shall be voided, and RYOBI disclaims any liabilities whatsoever for
any loss, personal injury, or damage.
DANGER :
Ce compresseur / pompe n’est pas équipé et ne doit pas être utiliser pour fournir de l’air de qualité respirable. Un
équipement supplémentaire est nécessaire pour filtrer et purifier l’air conformément aux spécifications minimum d’air
respirable de qualité D G 7.1 - 1966, OSHA 29 CFR 1910. 134 de la Compressed Gas Association, 4221 Walney Road,
Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700, www.cganet.com. Un tel équipement n’a pas été examiné et nulle
implacation d’utilisation propre pour l’air respirable n’est prévue ou implicite.
Si ce compresseur est modifier de quelle que manière que ce soit, les garanties en vigueur seront déclarées nulles et
non avenues. RYOBI et One World Technologies, Inc., déclineront toute responsabilité pour les pertes, blessures et
dommages résultant de son utilisation.
EXONÉRATION DE GARANTIES
Si ce compresseur est utilisé pour des applications d’air respirable sans un système de sécurité et d’alarme approprié,
les garanties en vigueur seront déclarées nulles et non avenues et RYOBI déclinera toute responsabilité pour les pertes,
blessures et dommages résultant de son utilisation.
PELIGRO:
Este compresor (o bomba) no está equipado y debe evitarse utilizarlo para suministrar aire para respirar. Es necesario
equipo adicional para filtrar y purificar debidamente el aire a fin de que cumpla las especificaciones mínimas de Grado
D para respiración, según se explica en la Especificación de Productos G 7.1 - 1966 de la Asociación de Proveedores
de Equipo de Gas Comprimido (Compressed Gas Association), OSHA 29 CFR 1910.134. Compressed Gas Association,
4221 Walney Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700, www.cganet.com. Tal equipo adicional no ha
sido examinado y no debe suponerse o deducirse ninguna conclusión con respecto al correcto uso del aire de respiración.
Si se altera de cualquier forma este compresor, quedan anuladas todas las garantías presentes. RYOBI y One World
Technologies, Inc., se eximen de toda responsabilidad de cualquier tipo por cualquier pérdida, lesión corporal o daño
material.
EXTENCIÓN DE RESPONSABILIDAD DE LAS GARANTÍAS
En caso de utilizarse los compresores para suministrar aire de respiración, y no utilizarse simultáneamente equipo en línea
de seguridad y alarma apropiado, se anulan todas las garantías presentes, y RYOBI se exime de toda responsabilidad
de cualquier tipo por cualquier pérdida, lesión física o daño material que resulte.
3 – English
WARNING:
Read and understand all instructions. Failure to follow
all instructions listed below may result in electric shock,
fire, and/or serious personal injury.
SAVE THESE INSTRUCTIONS
WORK AREA
Keep your work area clean and well lit. Cluttered
benches and dark areas invite accidents. Floor must not
be slippery from wax or dust.
Do not operate air compressors in explosive atmo-
spheres, such as in the presence of flammable liquids,
gases, or dust. Power tools create sparks which may
ignite the dust or fumes.
Keep bystanders, children, and visitors away while op-
erating an air compressor. Distractions can cause you to
lose control.
Operate air compressor in an open area at least 18 in.
away from any wall or object that could restrict the
flow of fresh air to ventilation openings.
ELECTRICAL SAFETY
Avoid body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators. There is an
increased risk of electric shock if your body is grounded.
Don’t expose air compressors to rain or wet condi-
tions. Water entering an air compressor will increase the
risk of electric shock.
Use this product only with batteries and chargers listed
in tool/appliance/battery pack/charger correlation
supplement 987000-432. Use of other battery packs or
chargers may create a risk of injury or fire.
PERSONAL SAFETY
Eye protection which conforms to ANSI specifications
and provides protection against flying particles both
from the FRONT and SIDE should ALWAYS be worn by
the operator and others in the work area when load-
ing, operating, or servicing this product. Eye protection
is required to guard against flying fasteners and debris,
which could cause severe eye injury.
The employer and/or user must ensure that proper
eye protection is worn. We recommend a Wide Vision
Safety Mask for use over eyeglasses or standard safety
glasses that provide protection against flying particles
both from the front and side. Always use eye protection
which is marked to comply with ANSI Z87.1.
Additional safety protection will be required in some
environments. For example, the working area may in-
clude exposure to a noise level which can lead to hearing
damage. The employer and user must ensure that any
necessary hearing protection is provided and used by the
operator and others in the work area. Some environments
will require the use of head protection equipment. When
required, the employer and user must ensure that head
protection marked to comply with ANSI Z89.1 is used.
Stay alert, watch what you are doing, and use com-
mon sense when operating the air compressor. Do
not use product while tired or under the influence of
drugs, alcohol, or medication. A moment of inattention
while operating an air compressor may result in serious
personal injury.
Dress properly. Do not wear loose clothing or jewelry.
Contain long hair. Keep your hair, clothing, and gloves
away from moving parts. Loose clothes, jewelry, or long
hair can be caught in moving parts.
Do not overreach. Keep proper footing and balance
at all times. Proper footing and balance enables better
control of the product in unexpected situations.
Use safety equipment. Always wear eye protection.
Dust mask, nonskid safety shoes, hard hat, or hearing
protection must be used for appropriate conditions.
Do not use on a ladder, rooftop, or any inclined, el-
evated, or unstable support. Stable footing on a solid
surface enables better control of the air compressor in
unexpected situations.
SERVICE
When servicing a product, use only identical
replacement parts. Follow instructions in the
Maintenance section
of this manual. Use of unauthorized
parts or failure to follow Maintenance instructions may
create a risk of injury.
Service must be performed only by qualified repair
personnel. Service or maintenance performed by un-
qualified personnel may result in a risk of injury.
Remove the battery pack, open drain valve to de-
compress tanks and allow water to drain, and allow
air compressor to become cool to the touch before
servicing. Turn pressure regulator knob fully counter-
clockwise after shutting off air compressor.
GENERAL SAFETY RULES
4 – English
Know your air compressor. Read operator’s manual
carefully. Learn its applications and limitations, as well
as the specific potential hazards related to this product.
Following this rule will reduce the risk of electric shock,
fire, or serious injury.
Do not exceed the pressure rating of any component
in the system.
Protect material lines and air lines from damage or
puncture. Keep hose away from sharp objects, chemical
spills, oil, solvents, and wet floors.
Check hoses for weak or worn condition before each
use, making certain all connections are secure. Do not
use if defect is found. Purchase a new hose or notify an
authorized service center for examination or repair.
Release all pressures within the system slowly. Dust
and debris may be harmful.
Store idle air compressors out of the reach of children
and other untrained persons. Air compressors are dan-
gerous in the hands of untrained users.
Maintain air compressors with care. Follow mainte-
nance instructions. Properly maintained products are
easier to control.
Check for misalignment or binding of moving parts,
breakage of parts, and any other condition that may
affect the product’s operation. If damaged, have the
air compressor serviced before using. Many accidents
are caused by poorly maintained products.
Keep the exterior of the air compressor dry, clean, and
free from oil and grease. Always use a clean cloth when
cleaning. Never use brake fluids, gasoline, petroleum-
based products, or any strong solvents to clean the unit.
Following this rule will reduce the risk of deterioration of
the enclosure plastic
Drain tanks of moisture after each day’s use.
If unit will not be used for a while, it is best to leave drain
valve open until such time as it is to be used. This will
allow moisture to completely drain out and help prevent
corrosion on the inside of tanks.
Risk of Fire or Explosion. When used in conjunction with
a dedicated spray system, do not spray flammable liquid
in a confined area. Spray area must be well ventilated. Do
not smoke while spraying or spray where spark or flame
is present. Keep compressors as far from the spraying
area as possible, at least 25 feet from the spraying area
and all explosive vapors.
Risk of Bursting. Do not adjust regulator to result in
output pressure greater than marked maximum pressure
of attachment. Do not use at pressure greater than 120 psi.
To reduce the risk of electric shock, do not expose to
rain. Store indoors.
Inspect tanks yearly for rust, pin holes, or other
imperfections that could cause it to become unsafe.
Never weld or drill holes in the air tanks.
Make sure the hose is free of obstructions or snags.
Entangled or snarled hoses can cause loss of balance or
footing and may become damaged.
Use the air compressor only for its intended use. Do
not alter or modify the unit from the original design
or function.
Always be aware that misuse and improper handling of
this product can cause injury to yourself and others.
Never leave a tool unattended with the air hose
attached.
Never point any air tool toward yourself or others.
Do not operate this air compressor if it does not
contain a legible warning label.
Do not continue to use a tool or hose that leaks air or
does not function properly.
Always disconnect the air supply, turn the unit off, and
remove the battery pack before making adjustments,
servicing a product, or when a product is not in use.
Do not attempt to pull or carry the air compressor by
the hose.
Your tool may require more air consumption than this
air compressor is capable of providing.
Always follow all safety rules recommended by the
manufacturer of your air tool, in addition to all safety
rules for the air compressor. Following this rule will
reduce the risk of serious personal injury.
Never direct a jet of compressed air toward people or
animals. Take care not to blow dust and dirt towards
yourself or others. Following this rule will reduce the risk
of serious injury.
Do not use this air compressor to spray chemicals or
paint. Your lungs can be damaged by inhaling toxic fumes.
A respirator may be necessary in dusty environments.
SPECIFIC SAFETY RULES
5 – English
Inspect hoses periodically. Replace damaged hoses.
Following this rule will reduce the risk of serious personal
injury.
Check damaged parts. Before further use of the air
compressor or air tool, a guard or other part that is
damaged should be carefully checked to determine
that it will operate properly and perform its intended
function. Check for alignment of moving parts, binding
of moving parts, breakage of parts, mounting, and
any other conditions that may affect its operation. A
guard or other part that is damaged should be properly
repaired or replaced by an authorized service center.
Following this rule will reduce the risk of shock, fire, or
serious injury.
This equipment incorporates parts, such as snap
switches, receptacles, and the like that tend to pro-
duce arcs or sparks and, therefore, when located in a
garage, it should be in a room or enclosure provided for
the purpose, or should be 18 in. or more above the floor.
Never store a tool with air connected. Storing the tool
with air connected can result in unexpected firing and
possible serious personal injury.
Protect your lungs. Wear a face or dust mask if the
operation is dusty. Following this rule will reduce the risk
of serious personal injury.
Recharge only with the charger specified by the
manufacturer. A charger that is suitable for one type
of battery pack may create a risk of fire when used with
another battery pack.
Use power tools only with specifically designated bat-
tery packs. Use of any other battery packs may create
a risk of injury and fire.
When battery pack is not in use, keep it away from
other metal objects, like paper clips, coins, keys, nails,
screws or other small metal objects, that can make a
connection from one terminal to another. Shorting the
battery terminals together may cause burns or a fire.
Under abusive conditions, liquid may be ejected from
the battery; avoid contact. If contact accidentally
occurs, flush with water. If liquid contacts eyes, ad-
ditionally seek medical help. Liquid ejected from the
battery may cause irritation or burns.
Battery tools do not have to be plugged into an elec-
trical outlet; therefore, they are always in operating
condition. Be aware of possible hazards when not
using your battery tool or when changing accessories.
Following this rule will reduce the risk of electric shock,
fire, or serious personal injury.
Do not place battery tools or their batteries near fire
or heat. This will reduce the risk of explosion and possibly
injury.
Do not crush, drop or damage battery pack. Do not
use a battery pack or charger that has been dropped
or received a sharp blow. A damaged battery is subject
to explosion. Properly dispose of a dropped or damaged
battery immediately.
Batteries can explode in the presence of a source
of ignition, such as a pilot light. To reduce the risk of
serious personal injury, never use any cordless product
in the presence of open flame. An exploded battery can
propel debris and chemicals. If exposed, flush with water
immediately.
Do not charge battery tool in a damp or wet location.
Following this rule will reduce the risk of electric shock.
For best results, your battery tool should be charged
in a location where the temperature is more than 50°F
but less than 100°F. To reduce the risk of serious personal
injury, do not store outside or in vehicles.
Under extreme usage or temperature conditions, bat-
tery leakage may occur. If liquid comes in contact with
your skin, wash immediately with soap and water. If
liquid gets into your eyes, flush them with clean water
for at least 10 minutes, then seek immediate medical
attention. Following this rule will reduce the risk of seri-
ous personal injury.
Do not use a battery pack that is damaged or modified.
Damaged or modified batteries may exhibit unpredictable
behavior resulting in fire, explosion or risk of injury.
Do not modify or attempt to repair a battery pack that
has been damaged.
Do not expose a battery pack or appliance to fire or
excessive temperature. Exposure to fire or temperature
above 265°F may cause explosion.
Follow all charging instructions and do not charge the
battery pack or appliance outside of the temperature
range specified in the instructions. Charging improperly
or at temperatures outside of the specified range may
damage the battery and increase the risk of fire.
Have servicing performed by a qualified repair person
using only identical replacement parts. This will ensure
that the safety of the product is maintained.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you
loan someone this product, loan them these instructions
also.
SPECIFIC SAFETY RULES
6 – English
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual To reduce the risk of injury, user must read and understand
operator’s manual before using this product.
Eye Protection Always wear eye protection with side shields marked to comply
with ANSI Z87.1.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Recycle Symbol
This product uses lithium-ion (Li-ion) batteries. Local, state or
federal laws may prohibit disposal of batteries in ordinary trash.
Consult your local waste authority for information regarding avail-
able recycling and/or disposal options.
Risk of Bursting
Do not adjust regulator to result in output pressure greater than
marked maximum pressure of attachment. Do not use at pressure
greater than 120 PSI.
Risk of Fire or Explosion
Do not spray flammable liquid in a confined area. Spray area must
be well ventilated. Do not smoke while spraying or spray where
spark or flame is present. Keep compressors as far from the spray-
ing area as possible, at least 25 feet from the spraying area and
all explosive vapors.
Hot Surface To reduce the risk of injury or damage, avoid contact with any hot
surface.
Risk to Breathing Air obtained directly from the air compressor should never be used
to supply air for human consumption.
SYMBOL NAME DESIGNATION/EXPLANATION
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER: Indicates a hazardous situation, which, if not avoided, will result in death or
serious injury.
WARNING: Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.
CAUTION: Indicates a hazardous situation, that, if not avoided, may result in minor or
moderate injury.
NOTICE:(Without Safety Alert Symbol) Indicates information considered important, but
not related to a potential injury (e.g. messages relating to property damage).
SYMBOLS
7 – English
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
V Volts Voltage
Direct Current Type or a characteristic of current
n
o
No Load Speed Rotational speed, at no load
SYMBOL NAME DESIGNATION/EXPLANATION
GLOSSARY OF TERMS
Pressure Regulator Knob
Regulates the outgoing pressure from the air outlet to the
tool. It is possible to increase or decrease the pressure at
the outlet by adjusting this control knob.
Pressure Switch
Automatically controls the on/off cycling of the compressor.
It stops the compressor when the cut-off pressure in the tank
is reached and starts the compressor when the air pressure
drops below the cut-in pressure.
PSI (Pounds Per Square Inch)
Measurement of the pressure exerted by the force of the
air. The actual psi is measured by a pressure gauge on the
compressor.
Pump
Produces the compressed air with a reciprocating piston
contained within the cylinder.
Regulator Pressure Gauge
Displays the current line pressure. Line pressure is adjusted
by rotating the pressure regulator knob.
Safety Valve
Prevents air pressure in the air tank from rising over a
predetermined limit.
SCFM (Standard Cubic Feet Per Minute) or CFM (Cubic
Feet Per Minute)
A unit of measure of air delivery.
Tank Pressure Gauge
Indicates the pressure in the air tank.
Air Filter
Porous element contained within a metal or plastic housing
attached to the compressor cylinder head which removes
impurities from the intake air of the compressor.
Air Tank
Cylindrical component which contains the compressed air.
Check Valve
Device that prevents compressed air from flowing back from
the air tank to the compressor pump.
Circuit Breaker
Automatically shuts off the compressor if the temperature of
the electric motor exceeds a predetermined limit.
Cut-In Pressure
The low pressure at which the motor will automatically restart.
Cut-Off Pressure
The high pressure at which the motor will automatically
shut off.
Electric Motor
Device which provides the rotational force necessary to
operate the compressor pump.
Auto On/Off Switch
Control which turns the air compressor on or off. The
pressure switch will not automatically start and control the
compressor unless the manual Auto On/Off switch is in the
Auto On position.
NPT (National Pipe Thread)
A seal thread tape must be used to provide a leak-free seal
on pipe threaded connections.
SYMBOLS
GLOSSARY OF TERMS
8 – English
PRODUCT SPECIFICATIONS
Air Tank Capacity .......................................................1 gal.
Air Pressure .................................................... 120 psi max.
Air Delivery ..................................Up to .75 SCFM @ 40 psi
Up to .5 SCFM @ 90 psi
Tested per ISO1217
Gauges .......................................................1.7 in. diameter
Motor ..................................................................... 18 V DC
ASSEMBLY
WARNING:
Do not use this product if it is not completely assembled
or if any parts appear to be missing or damaged. Use of
a product that is not properly and completely assembled
or with damaged or missing parts could result in serious
personal injury.
WARNING:
Do not attempt to modify this product or create acces-
sories or attachments not recommended for use with this
product. Any such alteration or modification is misuse
and could result in a hazardous condition leading to
possible serious personal injury.
If any parts are damaged or missing, please call 1-800-525-2579 for assistance.
OPERATION
DANGER:
Do not disassemble check valve, tank drain valves or
safety relief valve with air in tank — bleed tanks. Failure
to depressurize tank could result in explosion and/or
serious personal injury.
WARNING:
Do not allow familiarity with products to make you care-
less. Remember that a careless fraction of a second is
sufficient to inflict severe injury.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes resulting in possible
serious injury.
WARNING:
Do not use any attachments or accessories not recom-
mended by the manufacturer of this product. The use of
attachments or accessories not recommended can result
in serious personal injury.
WARNING:
This equipment incorporates parts, such as snap switch-
es, receptacles, and the like that tend to produce arcs or
sparks and, therefore, when located in a garage, it should
be in a room or enclosure provided for the purpose, or
should be 18 in. or more above the floor.
WARNING:
Do not attach any tools to the open end of the hose until
start-up has been completed.
WARNING:
Always remove battery pack from the tool when you are
assembling parts, making adjustments, cleaning, or when
not in use. Removing battery pack will prevent accidental
starting that could cause serious personal injury.
NOTICE:
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
FEATURES
ASSEMBLY
OPERATION
9 – English
To disconnect an air hose or an air tool:
Confirm that the outlet pressure is at zero (0) psi.
When disconnecting a hose from 1/4-in. quick coupler,
always firmly hold release end of hose.
Pull back on the release sleeve on the 1/4-in. quick
coupler.
With a firm grip, pull out the quick-connect air fitting that
is attached to the quick coupler.
BREAK-IN PERIOD
Before first use, install a fully charged 4.0 Ah battery pack,
then run the air compressor at zero tank pressure with the
drain valve fully open for 30 minutes or until the battery pack
is completely discharged, whichever happens first.
TURNING THE AIR COMPRESSOR ON/OFF
See Figure 3, page 14.
Install the battery pack.
Move the Auto On/Off switch to the AUTO ON (I) position
to power the compressor on.
To turn the air compressor off, move the Auto On/Off
switch to the OFF (O) position.
NOTE: When the compressor is in the AUTO ON (I) position,
the air compressor will automatically turn back on when
the designated tank air pressure drops below the preset
pressure limit. It will also shut off again when the cut-off
pressure is reached.
WARNING:
Never exceed the air tool’s pressure rating as recom-
mended by the manufacturer. When using this air com-
pressor as an inflation device, always follow the maximum
inflation guidelines stated by the manufacturer of the item
being inflated.
WARNING:
Always ensure the switch is in the OFF (O) position and
the regulator pressure gauge reads zero before changing
air tools or disconnecting the hose from the air outlet.
Failure to do so could result in possible serious personal
injury.
APPLICATIONS
Air compressors are utilized in a variety of air system applica-
tions. Match hoses, connectors, air tools, and accessories
to the capabilities of the air compressor.
You may use this product for the purposes listed below:
Operating light- to medium-duty air-powered tools
Operating air accessories such as air nozzles and
automotive tire chucks
INSTALLING/REMOVING BATTERY PACK
See Figure 1, page 13.
Make sure the air compressor is turned off.
Insert a fully charged battery pack into the product as
shown.
NOTE: For best performance, a 4.0 Ah battery pack is
recommended.
Make sure the latches on each side of the battery pack
snap into place and the battery pack is secured in the
product before beginning operation.
Depress the latches to remove the battery pack.
For complete charging instructions, see the operator’s manu-
als for your battery pack and charger.
CONNECTING/DISCONNECTING AIR HOSE
(HOSE NOT PROVIDED)
See Figure 2, page 13.
WARNING:
Never exceed the air tool’s pressure rating as recom-
mended by the manufacturer. When using this air com-
pressor as an inflation device, always follow the maximum
inflation guidelines stated by the manufacturer of the item
being inflated.
Make sure the air compressor is turned off and the battery
pack is not installed.
Rotate pressure regulator knob fully in the counter-
clockwise direction so that the outlet pressure is at
zero (0) psi.
Attach hose with quick connect air fitting to 1/4 in. quick
coupler on air compressor. Make sure to push the hose
adaptor end fully into the coupler until the sleeve springs
forward to lock it in place.
NOTE: Your air hose can be looped around the hose wrap
brackets for storage or any time the air compressor is not
in use.
OPERATION
10 – English
OPERATION
USING THE AIR COMPRESSOR
See Figure 4, page 14.
WARNING:
Risk of bursting. Do not adjust pressure regulator
knob to result in output pressure greater than marked
maximum pressure of attachment and/or the item being
inflated. Never use at pressure greater than 120 psi. Fail-
ure to heed this warning could result in possible serious
personal injury.
WARNING:
Air powered tools may require more air consumption
than this air compressor is capable of providing. Check
the tool manual to avoid damage to the tool or risk of
personal injury.
Ensure that the Auto On/Off switch is in the OFF position
and the battery pack is not installed.
Attach air hose following the instructions in Connecting/
Disconnecting Air Hose (hose not provided).
Attach 1/4 in. NPT quick-connect air fitting to the
accessory or tool you intend to use.
Insert the other end of the quick-connect air fitting to the
quick coupler on the open end of hose.
Install the battery pack.
Move the Auto On/Off switch to the Auto On position.
Set the amount of air pressure desired using the pressure
regulator knob. Pull the knob out, then turn clockwise to
increase or counterclockwise to decrease the air pressure
through the hose. When the desired pressure is set, push
the knob back in to lock.
NOTE: Always use the minimum amount of pressure
necessary for your application. Using a higher pressure
than needed will drain air from the tank more rapidly,
cause the unit to cycle on more frequently, and reduce
battery run time between charges.
Following all safety precautions in this manual and the
manufacturer’s instructions in the air tool manual, you
may now proceed to use your air-powered tool.
NOTE: The air compressor will shut off during an electri-
cal overload. To reset the internal overload switch, turn
off the air compressor and allow the unit to cool. Remove
and then reinstall the battery packs before resuming
operation.
When finished, always drain the tank, turn the unit off,
and remove the battery packs. Never leave the unit on
and/or running unattended.
DRAINING THE TANK
See Figures 5 - 6, page 14.
To help prevent tank corrosion and keep moisture out of the air
used, the air tank of the compressor should be drained daily.
To drain:
Turn the air compressor off and remove the battery packs.
Pull the ring on the safety valve to release air until tank
pressure gauge reads less than 20 psi.
Release the ring.
Turn the drain valves 90° counterclockwise to the ON
(open) position.
Tilt tank to drain moisture from tank into a suitable
container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
If a drain valve is clogged, release all air pressure, remove
and clean valve, then reinstall.
WARNING:
Turn off the air compressor, remove battery packs, and
release all air from the tank before servicing. Failure to
depressurize tank before attempting to remove valve
could cause serious personal injury.
Turn the drain valves 90° clockwise to the OFF (closed)
position.
WARNING:
RISK OF BURSTING. All compressed air tanks have a
limited lifespan. The lifespan can be affected by a num-
ber of factors, including operating conditions of the air
compressor, proper maintenance of the tank, and unau-
thorized repairs and modifications. Since deterioration of
the tank can occur internally with no outward signs, the
air tank(s) on this compressor MUST be removed from
service by the end of the year shown on the data label.
Use of the air compressor after this date increases the
risk of an air tank rupture, which could result in serious
personal injury.
OPERATION
11 – English
MAINTENANCE
WARNING:
Always release all pressure, remove the battery packs,
and allow unit to cool to the touch before cleaning or
making repairs on the air compressor.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes resulting in possible
serious injury.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or de-
stroy plastIc which could result in serious personal injury.
STORING THE AIR COMPRESSOR
Place the Auto On/Off switch in the OFF position.
Remove the battery pack.
Disconnect air hose and air tool from the product.
Drain air tanks according to instructions.
Thoroughly clean air compressor and any accessories.
Hoses may be stored using the hose wrap brackets on
the air compressor.
OPERATION
CHECKING THE SAFETY VALVE
See Figure 5, page 14.
DANGER:
Do not attempt to tamper with the safety valve. Anything
loosened from this device could fly up and hit you. Fail-
ure to heed this warning could result in death or serious
personal injury.
The safety valve will automatically release air if the air tank
pressure exceeds the cut-out pressure. The valve should be
checked before each day of use by pulling the ring by hand.
Install the battery pack.
Turn the air compressor on and allow the tank to fill. The
compressor will shut off when the pressure reaches the
cut-out pressure.
Turn the air compressor off.
Pull the ring on the safety valve to release air for three to
five seconds to allow pressurized air to escape. Release
the ring. The safety release valve must reset and hold
pressure before all compressed air is exhausted from the
tank/pressure vessel.
Any continued loss of air after performing the above steps
indicates a problem with the safety valve. Discontinue
use and seek service before continued use of the air
compressor.
WARNING:
If air leaks after the ring has been released or if the valve is
stuck and cannot be actuated by the ring, do not use the
air compressor until the safety valve has been replaced.
Use of the air compressor in this condition could result
in serious personal injury.
OPERATION
MAINTENANCE
12 – English
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Compressor will not run Battery is not charged
Pressure switch bad
Tank is full of air
Internal overload switch is tripped
Recharge battery pack
Take compressor to service center
Compressor will turn on when tank pressure
drops to cut-in pressure
Turn off compressor and allow unit to cool;
remove and reinstall battery packs
Motor hums but cannot run
or runs slowly
Shorted or open motor winding
Defective check valve or unloader
Take compressor to service center
Take compressor to service center
Internal overload switch trips
repeatedly
Lack of proper ventilation/room temperature
too high
Electrical overload
Move compressor to well-ventilated area
Turn off unit and allow to cool; remove and
reinstall battery packs.
Air tank pressure drops when
compressor shuts off
Loose connections (fittings, tubing, etc.)
Loose drain valve / open drain valve
Check valve leaking
Check all connections with soap and water
solution and tighten
Tighten drain valve / close drain valve
Take compressor to service center
DANGER:
Do not disassemble check valve, tank drain
valves or safety relief valve with air in tank
— bleed tank.
Excessive moisture in dis-
charge air
Excessive water in air tank
High humidity
Drain tank
Move to area of less humidity; use air line filter
Compressor runs continu-
ously
Defective pressure switch
Excessive air usage
Take compressor to service center
Decrease air usage; compressor not large
enough for tool’s requirement
Air output lower than normal Broken inlet valves
Connections leaking
Take compressor to service center
Tighten connections
NOTE: ILLUSTRATIONS START ON PAGE 13 AFTER FRENCH
AND SPANISH LANGUAGE SECTIONS.
TROUBLESHOOTING
3 – Français
RÈGLES DE SÉCURITÉ GÉNÉRALES
AVERTISSEMENT :
Lire et veiller à bien comprendre toutes les
instructions. Le non-respect de toutes les instructions
ci-dessous peut entraîner un choc électrique, un incendie
et/ou des blessures graves.
CONSERVER CES INSTRUCTIONS
LIEU DE TRAVAIL
Garder le lieu de travail propre et bien éclairé. Les
établis encombrés et les endroits sombres sont propices
aux accidents. Le sol ne doit pas être rendu glissant par
de la cire ou de la sciure.
Ne pas utiliser d’outils électriques dans des
atmosphères explosives, par exemple en présence
de liquides, gaz ou poussières inflammables. Les
outils électriques produisent des étincelles risquant
d’enflammer les poussières ou vapeurs.
Garder les badauds, enfants et visiteurs à l’écart
pendant l’utilisation d’outils. Les distractions peuvent
causer une perte de contrôle.
Utiliser le compresseur d’air dans un endroit dégagé,
à au moins 457 mm (18 po) de toute paroi ou objet
risquant de gêner l’entrée de l’air dans les ouvertures
de ventilation.
SÉCURITÉ ÉLECTRIQUE
Éviter tout contact du corps avec des surfaces mises
à la terre, telles que tuyaux, radiateurs, cuisinières
et réfrigérateurs. Le risque d’électrocution est accru
lorsque le corps est mis à la terre.
Ne pas exposer les outils électriques à la pluie ou
l’humidité. La pénétration d’eau dans ces outils accroît
le risque de choc électrique.
Utilisez ce produit uniquement avec des batteries
et des chargeurs répertoriés dans le supplément de
raccordement pour chargeur/outils/piles/appareil
987000-432. L’utilisation d’autre bloc-piles ou chargeurs
représente un risque de blessure et d’incendie.
SÉCURITÉ PERSONNELLE
Lors du chargement, de l’utilisation ou de l’entretien
de cet outil, l’opérateur et les personnes se trouvant
sur le lieu de travail doivent TOUJOURS porter
un dispositif oculaire à protection FRONTALE et
LATÉRALE, conforme aux normes ANSI. Une telle
protection est requise, car les clous/agrafes et débris
projetés peuvent causer des lésions oculaires graves.
Il incombe à l’employeur et/ou l’utilisateur de veiller
à ce qu’une protection oculaire adéquate soit
utilisée. Nous recommandons d’utiliser un masque
facial à champ de vision se portant par-dessus des
lunettes de vue ou de sécurité et potégeant des débris
projetés sur le devant et les côtés. Toujours porter
une protection oculaire certifiée conforme à la norme
ANSI Z87.1.
Des équipements de protection supplémentaires sont
requis dans certains environnements. Par exemple,
le lieu de travail peut présenter un niveau de bruit
susceptible d’entraîner des lésions auditives. Il incombe à
l’opérateur et à l’utilisateur qu’une protection audidive soit
fournie et utilisée par l’opérateur et les autres personnes
se trouvant sur le lieu de travail. Certains environnements
requièrent le port d’un casque. Il incombe à l’employeur
et/ou l’utilisateur de veiller à ce qu’un casque conforme
à la norme ANSI Z89.1 soit utilisé.
Rester attentif, prêter attention au travail et faire
preuve de bon sens lors de l’utilisation de tout
outil électrique. Ne pas utiliser cet outil en état de
fatigue ou sous l’influence d’alcool, de drogues ou
de médicaments. Un moment d’inattention pendant
l’utilisation d’un outil électrique peut entraîner des
blessures graves.
Porter une tenue appropriée. Ne porter ni vêtements
amples, ni bijoux. Attacher ou couvrir les cheveux
longs. Garder les cheveux, les vêtements et les gants
à l’écart des pièces en mouvement. Les vêtements
amples, bijoux et cheveux longs peuvent se prendre dans
les pièces en mouvement.
Ne pas travailler hors de portée. Toujours se tenir
bien campé et en équilibre. Une bonne tenue et un bon
équilibre permettent de mieux contrôler l’outil en cas de
situation imprévue.
Utiliser l’équipement de sécurité. Toujours porter une
protection oculaire. Suivant les conditions, le port d’un
masque antipoussière, de chaussures de sécurité, d’un
casque ou d’une protection auditive est recommandé.
Ne pas utiliser l’outil sur un échafaudage, un toit ou un
support incliné, élevée, ou instable. Une bonne tenue
et un bon équilibre permettent de mieux contrôler l’outil
en cas de situation imprévue.
DÉPANNAGE
Utiliser exclusivement des pièces identiques à celles
d’origine pour les réparations. Se conformer aux
instructions de la section Entretien de ce manuel.
L’usage de pièces non autorisées ou le non respect des
instructions d’entretien peut présenter des risques de
blessures.
Le dépannage des outils doit être confié exclusivement
à un personnel qualifié. Les réparations ou entretiens
effectués par des personnes non qualifiées présentent
des risques de blessures.
Retirer le bloc-pile, ouvrir le robinet de purge pour
relâcher la pression, laisser l’eau s’écouler et laisser
la machine refroidir avant de procéder à tout entretien.
Après avoir arrêté le compresseur, tourner le bouton du
détendeur à fond vers la gauche.
4 – Français
Apprendre à connaître l’outil. Lire attentivement le
manuel d’utilisation. Apprendre les applications et les
limites de l’outil, ainsi que les risques spécifiques relatifs
à son utilisation. Le respect de cette règle réduira les
risques d’incendie, de choc électrique et de blessures.
Ne pas dépasser les pressions nominales des
composants du système.
Protéger les flexibles d’alimentation et d’outil contre
les dommages et risques de perforation. Garder le
flexible et le cordon d’alimentation électrique à l’écart
de la chaleur, de l’huile, des solvants et sols humides ou
mouillés.
Avant chaque utilisation, s’assurer que les fexibles
ne sont pas affaiblis ou endommagés et vérifier tous
les branchements. Ne pas utiliser le compresseur si les
flexibles ne sont pas en bon état. Acheter de nouveaux
flexibles ou contacter un centre de réparations agréé,
pour les faire inspecter ou réparer.
Relâcher toutes les pressions du système lentement.
La projection de poussières et de débris peut être
dangereuse.
Ranger les outils non utilisés hors de portée des
enfants et des personnes n’ayant pas reçu des
instructions adéquates. Dans les mains de personnes
n’ayant pas reçu des instructions adéquates, les outils
sont dangereux.
Entretenir soigneusement les outils. Respecter toutes
les instructions d’entretien. Les outils correctement
entretenus sont plus faciles à contrôler.
Vérifier qu’aucune pièce mobile n’est mal alignée,
grippée ou brisée et s’assurer qu’aucun autre
problème risque d’affecter le bon fonctionnement
de l’outil. En cas de dommages, faire réparer l’outil
avant de l’utiliser de nouveau. Beaucoup d’accidents
sont causés par des outils mal entretenus.
Garder l’extérieur du compresseur sec, propre et
exempt d’huile ou de graisse. Toujours utiliser un chiffon
propre pour le nettoyage. Ne jamais utiliser de liquide de
freins, d’essence, de produits à base de pétrole ou de
solvants puissants pour nettoyer l’outil. Le respect de
cette règle réduira les risques de perte du contrôle et
d’endommagement du boîtier en plastique.
Purger le réservoir après chaque journée de travail.
Si le compresseur ne doit pas être utilisé pendant un
certain temps, il est préférable de laisser le robinet de
purge ouvert. Cela permettra d’évacuer complètement
l’humidité et aidera à empêcher la corrosion de l’intérieur
du réservoir.
Risque d’incendie ou d’explosion.
Quand utilisé avec
un système de pulvérisation dédié,
ne pas vaporiser de
liquides inflammables dans un endroit confiné. La zone de
pulvérisation doit être bien ventilée. Ne pas fumer pendant
la pulvérisation ou pulvériser en présence de flammes.
Garder les compresseurs le plus loin possible des zones
de pulvérisation, au moins à 7,6 m (25 pi) de la zone de
pulvérisation et de toutes vapeurs explosives.
Risque d’éclatement. Ne pas régler le détendeur pour
obtenir une pression de sortie supérieure à la pression
nominale de l’accessoire utilisé. Ne pas utiliser une
pression de plus de 827,4 kPa (120 psi).
Pour réduire le risque de choc électrique, ne pas
exposer à la pluie. Remiser à l’intérieur.
Une fois l’an, s’assurer que le réservoir n’est pas
rouillé ou piqué et ne présente aucun défaut risquant
de le rendre dangereux. Ne jamais percer ou souder le
réservoir.
S’assurer que le flexible n’est ni bloqué, ni accroché.
Un flexible emmêlé ou entortillé peut causer une perte
d’équilibre et être endommagé.
Le compresseur ne doit être utilisé que pour les
applications pour lesquelles il est conçu. Ne pas
altérer ou modifier le compresseur ou l’utiliser pour
des applications pour lesquelles il n’est pas conçu.
Ne jamais oublier qu’un usage incorrect ou abusif
de cet outil peut mettre l’opérateur et les autres
personnes présentes en danger.
Ne jamais laisser l’outil sans surveillance avec le
flexible d’air branché.
Ne pas pointer un outil quel qu’il soit vers soi ou
d’autres personnes.
Ne pas utiliser cet outil s’il ne comporte pas
d’autocollant d’avertissement.
Ne pas utiliser un outil qui présente des fuites d’air
ou ne fonctionne pas correctement.
Toujours débrancher l’alimentation d’air, éteindre
l’appareil et retirer le bloc-pile avant d’effectuer des
réglages, d’effectuer l’entretien du produit ou lorsque le
produit n’est pas utilisé.
Ne pas essayer de tirer ou de transporter le
compresseur par son flexible.
La consommation d’air de l’outil peut être supérieure
à la capacité de ce compresseur.
Toujours respecter les consignes de sécurité du
fabricant de l’outil pneumatique, ainsi que toutes les
règles de sécurité d’utilisation du compresseur. Le
respect de cette consigne réduira les risques de blessures
graves.
Ne jamais diriger le jet d’air comprimé vers des
personnes ou animaux. Veiller à ne pas projeter de la
poussière ou de la saleté vers soi-même ou d’autres
personnes. Le respect de cette règle réduira les risques
de blessures graves.
Ne pas utiliser ce compresseur pour la pulvérisation
de produits chimiques ou peinture. L’inhalation de
vapeurs toxiques peut causer des lésions pulmonaires.
Le port d’un respirateur peut être nécessaire dans les
environnements poussiéreux.
RÈGLES DE SÉCURITÉ PARTICULIÈRES
5 – Français
Inspecter régulièrement les tuyaux. Remplacer les
tuyaux endommagés. Le respect de cette consigne
réduira les risques de choc électrique et d’incendie.
Vérifier l’état des pièces. Avant d’utiliser le compresseur
de nouveau, examiner soigneusement les pièces et
dispositifs de protection qui semblent endommagés
afin de déterminer s’ils fonctionnent correctement
et remplissent les fonctions prévues. Vérifier
l’alignement des pièces mobiles, s’assurer qu’aucune
pièce n’est bloquée ou cassée, vérifier la fixation de
chaque pièce et s’assurer qu’aucun autre problème
ne risque d’affecter le bon fonctionnement de l’outil.
Toute protection ou pièce endommagée doit être
correctement réparée ou remplacée dans un centre
de réparations agréé. Le respect de cette consigne
réduira les risques de choc électrique, d’incendie et de
blessures graves.
Un cet équipement incorpore des parties,
commutateurs telles que de claquement, les prises,
et l’aimé qu’avoir tendance à produire des arcs ou des
étincelles et, donc, quand localisé dans un garage, ce doit
être dans une pièce ou la clôture a pourvu au but, ou doit
être 457 mm (18 po) ou plus au-dessus du plancher.
Ne jamais emmagasiner l’outil avec l’air connecté.
Emmagasiner l’outil avec l’air connecté peut avoir pour
résultat vider imprévu et la blessure personnelle, sérieuse
et possible.
Protection respiratoire. Porter un masque facial ou
respiratoire si le travail produit de la poussière. Le respect
de cette règle réduira les risques de blessures graves.
Ne recharger qu’avec l’appareil spécifié par le
fabricant. Un chargeur approprié pour un type de pile
peut créer un risque d’incendie s’il est utilisé avec un
autre type de pile.
Utiliser exclusivement le bloc-pile spécifiquement
indiqué pour l’outil. L’usage de tout autre bloc peut créer
un risque de blessures et d’incendie.
Lorsque le bloc-piles n’est pas en usage, le garder
à l’écart d’articles tels qu’attaches trombones,
pièces de monnaie, clous, vis ou autres petits objets
métalliques risquant d’établir le contact entre les deux
bornes. La mise en court-circuit des bornes de piles peut
causer des étincelles, des brûlures ou un incendie.
En cas d’usage abusif, du liquide peut s’échapper des
piles. Éviter tout contact avec ce liquide. En cas de
contact accidentel, rincer immédiatement les parties
atteintes avec de l’eau. En cas d’éclaboussure dans
les yeux consulter un médecin. Le liquide s’échappant
des piles peut causer des irritations ou des brûlures.
Les outils fonctionnant sur piles n’ayant pas besoin
d’être branchés sur une prise secteur, ils sont toujours
en état de fonctionnement. Tenir compte des dangers
possibles lorsque l’outil n’est pas en usage et lors du
remplacement des piles. Le respect de cette consigne
réduira les risques d’incendie, de choc électrique et de
blessures graves.
Ne pas placer les outils électriques sans fil ou leurs
piles à proximité de flammes ou d’une source de
chaleur. Ceci réduira les risques d’explosion et de
blessures.
Ne pas écraser, faire tomber ou endommager le bloc-
piles. Ne jamais utiliser un bloc-piles ou un chargeur
qui est tombé, a été écrasé, a reçu un choc violent ou a
été endommagé de quelque façon que ce soit. Une pile
endommagée risque d’exploser. Éliminer immédiatement
toute pile endommagée, selon une méthode appropriée.
Les piles peuvent exploser en présence d’une source
d’allumage, telle qu’une veilleuse. Pour réduire les
risques de blessures graves, ne jamais utiliser un appareil
sans fil, quel qu’il soit, en présence d’une flamme
vive. En explosant, une pile peut projeter des débris
et des produits chimiques. En cas d’exposition, rincer
immédiatement les parties atteintes avec de l’eau.
Ne pas recharger un outil fonctionnant sur piles dans
un endroit humide ou mouillé. Le respect de cette règle
réduira les risques de choc électrique.
Pour obtenir de meilleurs résultats, il importe de
charger l’outil dans un endroit où la température
est de plus de 10 °C (50 °F) mais de moins de 37 °C
(100 °F). Ne pas ranger à l’extérieur ou dans des véhicules
afin de réduire le risque de blessures graves.
Si l’outil est utilisé de façon intensive ou sous des
températures extrêmes, des fuites de pile peuvent se
produire. En cas de contact du liquide avec la peau,
rincer immédiatement la partie atteinte avec de l’eau.
En cas d’éclaboussure dans les yeux, les rincer à l’eau
fraîche pendant au moins 10 minutes, puis contacter
immédiatement un médecin. Le respect de cette règle
réduira les risques de blessures graves.
Ne pas utiliser un bloc-piles endommagé ou modifié.
Le bris ou la modification du bloc-piles peut causer un
comportement imprévisible et causer un incendie, une
explosion ou des blessures.
Ne pas modifier ou tenter de réparer un bloc-piles
ayant été endommagé.
Ne pas exposer le bloc-piles ou l’outil à un feu ou
à des températures excessives. Une exposition à
un incendie ou à une température supérieure à 130 °C
(265 °F) peut provoquer une explosion.
Suivre toutes les instructions afférentes à la recharge
et ne pas recharger le bloc-piles ou l’appareil hors des
températures spécifiées dans les instructions. Une
recharge incorrecte ou hors des températures spécifiées
peut endommager la pile et augmenter les risques de feu.
Demander à un réparateur qualifié d’effectuer la répa-
ration en utilisant des pièces de rechange identiques.
Ceci assurera la bonne sécurité du produit réparé.
Conserver ces instructions. Les consulter fréquemment
et les utiliser pour instruire les autres utilisateurs éventuels.
Si cet outil est prêté, il doit être accompagné de ces
instructions.
RÈGLES DE SÉCURITÉ PARTICULIÈRES
6 – Français
Certains des symboles ci-dessous peuvent être utilisés sur l’produit. Veiller à les étudier et à apprendre leur signification.
Une interprétation correcte de ces symboles permettra d’utiliser l’produit plus efficacement et de réduire les risques.
SYMBOLE NOM DÉSIGNATION/EXPLICATION
Symbole d’alerte de sécurité Indique un risque de blessure potentiel.
Lire manuel d’utilisation Pour réduire les risques de blessures, l’utilisateur doit lire et veiller à
bien comprendre le manuel d’utilisation avant d’utiliser ce produit.
Protection oculaire Toujours porter une protection oculaire avec écrans latéraux
certifiée conforme à la norme ANSI Z87.1.
Avertissement concernant
l’humidité Ne pas exposer à la pluie ou l’humidité.
Symbole de recyclage
Ce produit utilise les piles de lithium-ion (Li-ion). Les réglementations
locales ou gouvernementales peuvent interdire de jeter les piles dans
les ordures ménagères. Consulter les autorités locales compétentes
pour les options de recyclage et/ou l’élimination.
Risque d’éclatement
Ne pas régler le détendeur pour obtenir une pression de sortie
supérieure à la pression nominale de l’accessoire utilisé. Ne pas
utiliser une pression de plus de 827,4 kPa (120 psi).
Risque d’incendie ou
d’explosion
Ne pas vaporiser de liquides inflammables dans un endroit confiné.
La zone de pulvérisation doit être bien ventilée. Ne pas fumer
pendant la pulvérisation ou pulvériser en présence de flammes.
Garder les compresseurs le plus loin possible des zones de
pulvérisation, au moins à 7,6 m (25 pi) de la zone de pulvérisation
et de toutes vapeurs explosives.
Surface brûlante Pour éviter les risques de blessures ou de dommages, éviter tout
contact avec les surfaces brûlantes.
Les termes de mise en garde suivants et leur signification ont pour but d’expliquer le degré de risques associé à l’utilisation
de ce produit.
SYMBOLE SIGNAL SIGNIFICATION
DANGER : Indique une situation dangereuse qui, si elle n’est pas évitée, aura pour
conséquences des blessures graves ou mortelles.
AVERTISSEMENT : Indique une situation dangereuse qui, si elle n’est pas évitée, pourrait
entraîner des blessures graves ou mortelles.
ATTENTION : Indique une situation dangereuse qui, si elle n’est pas évitée, pourraît
entraîner des blessures légères ou de gravité modérée.
AVIS :
(Sans symbole d’alerte de sécurité) Indique les informations jugées
importantes sans toutefois représenter un risque de blessure (ex. : messages
concernant les dommages matériels).
SYMBOLES
7 – Français
Certains des symboles ci-dessous peuvent être utilisés sur l’produit. Veiller à les étudier et à apprendre leur signification.
Une interprétation correcte de ces symboles permettra d’utiliser l’produit plus efficacement et de réduire les risques.
SYMBOLE NOM DÉSIGNATION/EXPLICATION
Risques d’inhalation L’air sortant directement du compresseur ne doit jamais être utilisé
pour la respiration.
V Volts Tension
Courant continu Type ou caractéristique du courant
n
o
Vitesse à vide Vitesse de rotation à vide
Bouton de régulation de pression
Permet de contrôler la pression d’alimentation de l’outil. La
rotation du bouton dans un sens ou dans l’autre augmente
ou réduit la pression d’air.
Manostat
Commande automatiquement la mise en marche et l’arrêt
du moteur du compresseur. Il arrête le compresseur lorsque
la pression maximum du réservor est atteinte et le remet en
marche une fois que la pression est parvenue au minimum.
Livres par pouce carré (PSI)
Mesure de la pression exercée par la force de l’air. La pression
est indiquée par un manomètre monté sur le compresseur.
Pompe
Produit l’air comprimé au moyen d’un piston alternatif à
l’intérieur du cylindre.
Manomètre de détendeur
Indique la pression de ligne. La pression de ligne se règle au
moyen du bouton de commande du détendeur.
Soupape de sûreté
Empêche la pression d’air du réservoir de dépasser une
limite prédéterminée.
PCSM (Pieds Cubes Standard Minute) ou PCM (Pieds
Cubes Minute)
Unité de mesure du débit d’air.
Manomètre de réservoir
Indique la pression d’air à l’intérieur du réservoir.
Filtre à air
Élément poreux contenu dans un boîtier en métal ou plastique,
monté sur la culasse du compresseur pour débarasser l’air
d’alimentation de toutes ses impuretés.
Réservoir d’air
Composant cylindrique contenant l’air comprimé.
Soupape antiretour
Dispositif empêchant l’air comprimé contenu dans le réservoir
de retourner à la pompe.
Disjoncteur de circuit
Arrête automatiquement le compresseur lorsque la
température du moteur électrique dépasse une limite
prédéterminée.
Pression d’arrêt
Pression à laquelle le moteur s’arrête automatiquement.
Pression de déclenchement
Pression à laquelle le moteur se remet en marche.
Moteur électrique
Dispositif produisant la force rotative nécessaire pour
actionner la pompe du compresseur.
Commutateur de marche/arrêt automatique
Commande pour démarrer ou éteindre le compresseur
d’air. Le manostat ne fait pas automatiquement la mise en
marche du moteur et la commande de pression sauf si le
commutateur automatique marche/arrêt est en position de
Marche automatique.
NPT — National Pipe Thread
Un ruban d’étanchéité de filetage doit être utilisé sur tous
les raccords filetés, pour empêcher les fuites.
SYMBOLES
GLOSSAIRE
8 – Français
FICHE TECHNIQUE
Contenance du réservoir d’air .......................... 3,8 L (1 gal)
Pression d’air ............................... 827,4 kPa (120 psi) max.
Débit d’air ......0,02 m3/min (0,75 SCFM) @ 276 kPa (40 psi)
0,01 m3/min (0,5 SCFM) @ 620 kPa (90 psi)
Testé par ISO1217
Manomètres ....................... 43,2 mm (1,5 po) de diamètre
Moteur ................................................................. 18 V C.C.
AVERTISSEMENT :
Ne pas utiliser le produit s’il n’est pas complètement
assemblé ou si des pièces semblent manquantes
ou endommagées. L’utilisation d’un produit dont
l’assemblage est incorrect ou incomplet ou comportant
des pièces endommagées ou absentes représente un
risque de blessures graves.
AVERTISSEMENT :
Ne pas essayer de modifier cet outil ou de créer des
accessoires non recommandés. De telles altérations ou
modifications sont considérées comme un usage abusif
et peuvent créer des conditions dangereuses, risquant
d’entraîner des blessures graves.
Si des pièces manquent ou sont endommagées, veuillez appeler au 1-800-525-2579 pour obtenir de l’aide.
DANGER :
Ne pas retirer la soupape antiretour, les robinets de
vidange ou la soupape de sûreté lorsque le réservoir
contient de l’air - purger le réservoir. Ne pas dépressuriser
le réservoir représente un risque d’explosion et de
blessures graves.
AVERTISSEMENT :
Ne pas laisser la familiarité avec l’outil faire oublier la
prudence. Ne pas oublier qu’une fraction de seconde
d’inattention peut entraîner des blessures graves.
AVERTISSEMENT :
Toujours porter une protection oculaire avec écrans
latéraux certifiée conforme à la norme ANSI Z87.1. Si
cette précaution n’est pas prise, des objets peuvent être
projetés dans les yeux et causer des lésions graves.
AVERTISSEMENT :
Ne pas utiliser d’outils ou accessoires non recommandés
par le fabricant de ce produit. L’utilisation de pieces
et accessoires non recommandés peut entraîner des
blessures graves.
AVERTISSEMENT :
Ce produit comporte des pièces telles que des
interrupteurs à ressort, qui ont tendance à produire
des arcs ou des étincelles. Par conséquent, lorsque la
machine est utilisée dans un garage, elle doit être placée
à 457 mm (18 po) au-dessus du sol, dans une enceinte
ou un local séparé.
AVERTISSEMENT :
Toujours retirer la bloc-pile de l’outil au moment
d’assembler des pièces, d’effectuer des réglages et de
procéder au nettoyage, ou lorsque l’outil n’est pas utilisé.
Si cette précaution n’est pas prise, des objets peuvent
être projetés dans les yeux et causer des lésions graves.
AVERTISSEMENT :
Ne pas brancher d’outil pneumatique sur l’extrémité libre
du flexible avant que la mise en route soit achevée.
AVIS :
Ne pas utiliser dans des endroits poussiéreux ou
autrement contaminés. Le compresseur peut être
endommagé s’il est utilisé dans de tels environnements.
CARACTÉRISTIQUES
ASSEMBLAGE
UTILISATION
9 – Français
APPLICATIONS
Les compresseurs d’air sont utilisés pour diverses
applications. Les capacités nominales des flexibles, outils
pneumatiques et accessoires doivent correspondre à celle
du compresseur.
Ce produit peut être utilisé pour les applications ci-dessous :
Faire fonctionner des outils pneumatiques à pression
d’alimentation légère à moyenne
Alimentation d’accessoires pneumatiques tels que buses
à air et mandrins de gonfleurs de pneus
INSTALLATION/RETRAIT DU BLOC-PILE
Voir la figure 1, page 13.
S’assurer que le compresseur d’air est éteint.
Insérer le bloc-pile omplètement chargée dans l’outil
comme illustré.
NOTE : Pour une meilleure performance, un bloc-piles
de 4,0 Ah est recommandé.
 S’assurer que les loquets de chaque côté de la pile
s’enclenchent en place et que la pile est bien fixée à l’outil
avant de mettre l’outil en marche.
Relâcher les loquets pour retirer le bloc-piles.
Pour prendre connaissance des consignes de chargement,
consulter le manuel d’utilisation des piles et des chargeurs.
CONNEXION ET DÉBRANCHER D’UN
TUYAU À AIR (NON FOURNI)
Voir la figure 2, page 13.
AVERTISSEMENT :
Ne jamais dépasser la pression nominale de l’outil
aérien tel que recommandé par le fabricant. Lorsque
vous utilisez ce compresseur d’air comme un dispositif
de gonflage, toujours suivre les directives d’inflation
maximale indiquée par le fabricant de l’élément étant
gonflé.
S’assurer que le compresseur d’air est éteint et que la
bloc-pile sont retiré.
Tourner complètement le bouton de régulateur dans le
sens antihoraire pour garantir que la pression d’air à la
sortie est à zéro (0) kPa (psi).
Brancher le flexible muni du connecteur mâle sur le
coupleur à ressort du compresseur. Assurer se pousser
la fin d’adaptateur de tuyau entièrement dans l’attelage
jusqu’à ce que les printemps de manche expédient pour
le verrouiller à sa place.
NOTE : Vous pouvez enrouler votre tuyau à air autour des
supports à tuyau pour l’entreposer ou lorsqu’il n’est pas
utilisé.
Pour débrancher un tuyau à air ou un outil pneumatique :
S’assurer que la pression d’alimentation est de zéro
(0) kPa (psi).
Lors du débranchement d’un tuyau du coupleur à ressort
de 6,35 mm (1/4 po), toujours tenir fermement l’extrémité
libérée du tuyau.
Pousser vers l’arrière le manchon de relâchement sur le
coupleur à ressort de 6,35 mm (1/4 po).
En le tenant fermement, retirer le raccord à connexion
rapide du coupleur à ressort.
PÉRIODE DE RODAGE
Avant la première utilisation, installer la pile de 4,0 Ah, puis
faire fonctionner le compresseur d’air sans pression dans
le réservoir et le robinet de vidange complètement ouvert
pendant 30 minutes ou jusqu’à ce que la charge des blocs-
piles soit entièrement épuisée, selon la première éventualité.
METTRE LE COMPRESSEUR EN POSITION
MARCHE ET D’ARRÊT
Voir la figure 3, page 14.
Insérer la bloc-pile.
Avec le compresseur d’air a branché sur, placer le
commutateur au « AUTO MARCHE ( l ) » (ON) en la
position d’alimenter le compresseur sur.
Pour éteindre le compresseur d’air, placer le commutateur
marche/arrêt en la position « OFF ( O ) » (arrêt).
NOTE : Lorsque le compresseur d’air est réglé à la position
« ON ( l ) » (Marche), il se remet automatiquement en marche
lorsque la pression d’air du réservoir descend en dessous
de la pression de déclenchement. L’appareil s’arrête aussi
automatiquement lorsque de la pression d’arrêt est atteinte.
AVERTISSEMENT :
Ne jamais dépasser la capacité de pression recommandée
par le fabricant pour cet outil pneumatique. Au moment
d’utiliser ce compresseur d’air comme dispositif de
gonflage, respecter les instructions de gonflage maximal
prescrites par le fabricant de l’article à gonfler.
AVERTISSEMENT :
Toujours s’assurer que l’interrupteur est réglé à la position
OFF ( O ) et que le manomètre du régulateur indique
zéro avant de changer les outils pneumatiques ou de
débrancher le tuyau de la sortie d’air. L’inobservation de
cette règle peut entraîner des blessures graves.
UTILISATION
10 – Français
PURGE DES RÉSERVOIR
Voir les figures 5 et 6, page 14.
Pour éviter la corrosion de l’intérieur du réservoir et la présence
d’humidité dans l’air utilisé, le réservoir du compresseur doit
être purgé quotidiennement.
Pour purger :
Éteindre le compresseur d’air, retirer les blocs-piles et
évacuer tout l’air du réservoir avant d’effectuer l’entretien.
Tirer l’anneau sur la soupape de sûreté pour relâcher
jusqu’à ce que fait pression sur la jauge lit moins que
138 kPa (20 psi) par pouce carré.
Relâche l’anneau.
 Tournersur90˚verslalerobinetdepurgeenletournant
vers la droit à la position ON (ouvert).
Le réservoir de pente de n pour drainer l’humidité du
réservoir dans un récipient convenable.
NOTE : Les condensats sont polluants et doivent être
éliminé conformément aux réglementations locales.
Si les soupape d’égout sont obstruées, relâche toute
pression atmosphérique, enlever et nettoyer des
soupapes, alors réinstaller.
AVERTISSEMENT :
Éteindre le compresseur d’air, retirer les blocs-piles et
évacuer tout l’air du réservoir avant d’effectuer l’entretien.
Ne pas relâcher la pression du réservoir avant d’essayer
de retirer le robinet de purge peut entraîner des blessures
graves.
 Tournersur90˚verslalerobinetdepurgeenletournant
vers la droit à la position OFF (fermé).
AVERTISSEMENT :
RISQUE D’ÉCLATEMENT. Tous les réservoirs d’air
comprimé ont une durée de vie utile limitée. La durée de vie
utile peut être compromise par plusieurs facteurs incluant
les conditions de fonctionnement du compresseur d’air,
un entretien inadéquat du réservoir, des réparations ou
modifications non autorisées. Parce qu’une détérioration
du réservoir peut survenir sans indice extérieur, les
réservoirs d’air de ce compresseur DOIVENT être mis
hors service à la fin de l’année indiquée sur l’étiquette de
renseignements. L’utilisation du compresseur d’air après
cette date augmente le risque de rupture du réservoir d’air
et représente un risque de blessures graves.
UTILISATION DU COMPRESSEUR D’AIR
Voir la figure 4, page 14.
AVERTISSEMENT :
Risque d’éclatement
. Ne pas ajuster le bouton de
régulation de pression pour une pression de sortie
supérieure à la pression maximale indiquée sur l’accessoire
utilisé ou sur l’article gonflé. La pression ne doit jamais
dépasser 827,4 kPa (120 psi).
Le non-respect de cet
avertissement pourrait entraîner des blessures graves
ou mortelles.
AVERTISSEMENT :
La consommation d’air de l’outil peut être supérieure à
la capacité de ce compresseur. Consulter le manuel de
l’outil pour éviter des dommages ou des blessures.
S’assurer que l’interrupteur de marche/arrêt automatique
est la position OFF (arrêt) et que la bloc-pile ne sont pas
installée.
Fixer le flexible en suivant les instructions du chapitre
Connexion et débrancher d’un tuyau à air (non fourni).
Fixer un raccord rapide d’air de 6,3 mm (1/4 po) à filetage
NPT à l’accessoire ou l’outil à utiliser.
Insérer l’autre extrémité du raccord rapide d’air au
coupleur à ressort à la partie ouverte du tuyau.
Installer la bloc-pile.
Placer l’interrupteur de marche/arrêt automatique à la
position Auto On (automatique en marche).
Réguler la quantité de pression d’air désirée avec le
bouton de régulateur de pression. Tirez le bouton puis
tourner vers la droite pour augmenter ou vers la gauche
pour diminuer la pression d’air à livrer par le flexible.
Lorsque la pression désirée est régulée, appuyez le
bouton pour verrouiller.
NOTE : Toujours utiliser la pression minimale requise pour
l’application. Le fait d’utiliser inutilement une pression
plus élevée purge l’air du réservoir plus rapidement, fait en
sorte que le compresseur s’enclenche plus fréquemment,
and réduira l’autonomie de la pile entre les charges.
Une fois l’opération terminée, toujours vider le réservoir
et débrancher l’unité. Ne jamais laisser l’unité sans
surveillance si celle-ci est branchée ou si elle fonctionne.
NOTE : Le compresseur d’air s’arrêtera lors d’une
surcharge électrique. Pour pouvoir enclencher à nouveau
le disjoncteur de surcharge interne, débrancher le
compresseur d’air et laisser refroidir l’appareil. Retirer puis
réinstaller les blocs-piles avant de reprendre le travail.
Dès la fin de l’utilisation, toujours évacuer l’air du
réservoir, éteindre l’appareil et retirer les blocs-piles. Ne
jamais laisser l’appareil sous tension ou fonctionner sans
surveillance.
UTILISATION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Ryobi P739-PCL204KN Le manuel du propriétaire

Catégorie
Compresseurs d'air
Taper
Le manuel du propriétaire