WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
• Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliances.
• WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliances.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
150 PSI150 PSI
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
2
WARNING
This water heater may not be suitable for use in manufactured (mobile) homes! Please check local code
restrictions pertaining to permanent / fixed installations in manufactured homes in your area.
The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommenda-
tions for the proper installation and adjustment of the water heater; and two, to the owner-operator, to explain
the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual
also includes a parts list.
YOU'RE ALL SET!
Thanks for purchasing your new Camplux 20L residential tankless water heater. This convenient, safe and
high efficiency product will open the doors to enjoying endless hot water.
We highly suggest you take the time to read through all of the safety and installation procedures in this
manual, before attempting to install your new residential water heater.
Always remember we're here for you via our online helpdesk located at www.camplux.com, live chat and
toll free at (844)538-7475!
READ THIS MANUAL
READ THE SAFETY INFORMATION
Inside you will find many helpful hints on how to use and maintain your water heater properly.
A little preventive care on your part can save you time and money over the life of your water heater.
You’ll find many answers to common problems in the Troubleshooting Guide. If you review the chart of
Troubleshooting Tips first you may not need to call for service.
To Ensure your safety and the safety of others, we have included important safety warnings throughout this
manual.
All safety messages will follow the safety alert symbol and the words: “CAUTION”, “DANGER” “WARNING”or
“NOTICE”.
These words mean:
CAUTION - A potentially hazardous situation that may result in minor or moderate injury.
DANGER - An imminently hazardous situation that will result in death or serious injury.
WARNING - A potentially hazardous situation that could result in death or serious injury and/or
damage to property.
NOTICE: Attention is called to observe a specified procedure or maintain a specific condition.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
3
It is imperative that all persons who are expected to install, operate or adjust this water heater read the instruc-
tions carefully so they may understand how to perform these operations. If you don’t understand these
instructions or any terms within it, seek professional advice.
Any questions regarding the operation, maintenance, service or warranty of this water heater should be
directed to the seller from whom it was purchased. If additional information is required, refer to the section on
If You Need Service.
Do not destroy this manual. Please read carefully and keep in a safe place for future reference.
Recognize this symbol as an indication of Important Safety Information!
California Proposition 65 Warning: This product contains chemicals known to the State of California to
cause cancer, birth defects or other reproductive harm.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal
injury, or death. Refer to this manual. Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
DO NOT store or use gasoline or other flammable vapors or liquids or other combustible materials in the
vicinity of this or any other appliance. To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliances.
• DO NOT touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
• DO NOT return to your home until authorized by the gas supplier or fire department.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
4
www.camplux.com
Safety Information......................................................................................................................................................................................................
Installing The Water Heater....................................................................................................................................................................................
Warning & You’re All Set.........................................................................................................................................................................................
Operation ......................................................................................................................................................................................................................
Maintenance..................................................................................................................................................................................................................
Troubleshooting..........................................................................................................................................................................................................
Replacement Parts .....................................................................................................................................................................................................
In The Box......................................................................................................................................................................................................................
Warranty .........................................................................................................................................................................................................................
Related Residential Models......................................................................................................................................................................................
2-8
9-29
1-2
30-32
32-35
36-37
38
39
40
41
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this
water heater. It may save your time and money. Pay particular attention to the Safety Instructions. Failure to
follow these warnings could result in serious bodily injury or death. Should you have problems understanding
the instructions in this manual, or have any questions, STOP, and get help from a qualified service technician,
or the local gas utility.
DANGER
PROPERLY INSTALL WATER HEATER
Failure to properly install the water heater outdoors as outlined in the Installation Instructions in this manual
can result in unsafe operation of the water heater. To avoid the risk of fire, explosion, or asphyxiation from
carbon monoxide, never operate this water heater unless it is installed properly and has an adequate air supply
for proper operation. Be sure to inspect the flue terminal for proper installation at initial start-up. and at least
annually thereafter. Refer to the Care and Cleaning section of this manual for more information regarding flue
terminal inspection.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
5
WARNING
Gasoline, as well as other flammable materials and liquids (adhesives, solvents, paint thinners etc.), and the
vapors they produce are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or
combustible materials anywhere near or in the vicinity of a water heater or any other appliance. Be sure to read
and follow the labels on the water heater, as well as the warnings printed in this manual. Failure to do so can
result in property damage, bodily injury or death.
Vapors from flammable
liquids will explode and catch fire
causing death or severe burns
Do not use or store flammable products
such as gasoline, solvents or adhesives
In the same room or area near the
water heater
Keep flammable products :
1. Far away from heater
2. In approved containers
3. Tightly closed
4. Out of children ‘s reach
Water heater has a main burner flame.
The main burner flame
1. Can come on at any time and
2. Will ignite flammable vapors
Vapors:
1. Cannot be seen
2. Are heavier than air
3. Go a long way on the floor
4. Can be carried from other rooms to
the main burner flame by air currents
Installation:
Do not Install water heater where flammable products will be stored or used unless the main
burner flame Is at least 18” above the floor. This will reduce, but not eliminate, the risk of
vapors being ignited by the main burner flame.
Read and follow water heater warnings and Instructions. If owners manual is missing, contact
the retailer or manufacturer.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
DANGER
WATER TEMPERATURE SETTING
Safety and energy conservation are factors to be considered when selecting the water temperature setting.
Water temperatures above 125°F can cause severe burns or death from scalding. The thermostat is adjusted to
its lowest temperature position when shipped from the factory. Be sure to read and follow the warnings
outlined on the label pictured below.
DANGER: Households with small children, disabled, or elderly persons may require a 120°F or lower
temperature setting to prevent contact with”HOT” water.
Maximum water temperature occurs while burner is on. To find water temperature being delivered, turn on a
hot water faucet and place a thermometer in the water stream and read the thermometer.
The temperature of the water at the outlet of the water heater can be regulated by setting the temperature on
display located on the front panel. The display located on the front panelwas set at 110°F before it was shipped
from the factory.
The illustration to the bottom left illustrates the Remote Control and how to adjust the water temperature.
NOTICE: When this water heater is supplying general purpose hot water requirements for use by individuals, a
thermostatically controlled mixing valve for reducing point of use water temperature is recommended to
reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further informa-
tion.
NOTICE: The factory recommended operating temperatures are between 90°F and 140°F.
www.camplux.com
6
Water Temperature
120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Time/Temperature Relationship in Scalds
The chart shown above may be used as a guide
in determining the proper water temperature for
your home
Table courtesy of Shriners Burn Institute
Water temperature over 125°F can cause severe burns
instantly or death from scalds. Children, disabled and elderly
are at highest risk of being scalded. See instruction manual
before setting temperature at water heater. Feel water
before bathing or showering. Temperature limiting valves are
available, see manual.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
7
DANGER
NATURAL GAS AND LIQUEFIED PETROLEUM MODELS
Both propane and natural gas have odorants added to aid in detecting a gas leak. Some people may not
physically be able to smell or recognize this odorants. If you are unsure or unfamiliar with the smell of propane
or natural gas, ask the gas supplier.
Other conditions, such as “odorants fade”, which causes the odorant to diminish in intensity, can also hide or
camouflage a gas leak. Always check with commercial leak odorants or soapy water.
• Gas detectors are recommended in propane and natural gas applications and their installation should be in
accor dance with the detector manufacturer’s recommendations and/or local laws, rules, regulations or
customs.
• Water heaters utilizing propane gas are different from natural gas models. A natural gas water heater will not
function safely on propane gas and vice versa.
• No attempt should ever be made to convert the water heater from natural gas to propane gas. To avoid
possible equipment damage, personal injury or fire, do not connect the water heater to a fuel type not in
accordance with the unit data plate; propane for propane units and natural gas for natural gas units. These
units are not certified for any other fuel type.
• Propane water heaters should not be installed. below grade (for example, in a basement) if such installation is
prohibited by federal, state and/or local laws, rules, regulations or customs.
• Propane or propane gas must be used with great caution. It is heavier than air and will collect first in lower
areas making it hard to detect at nose level.
• Before attempting to light the water heater, make sure to look and smell for gas leaks. Use a soapy solution
to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected.
When smelling to detect a gas leak, be sure to sniff near the floor also.
• It is recommended that more than one method, such as soapy solution, gas detectors, etc., be used to detect
leaks in gas applications.
Notice: If a gas leak is present or suspected:
• DO NOT attempt to find the cause yourself.
• DO NOT try to light any appliances.
• DO NOT touch any electrical switch.
• DO NOT use any phone in your building.
• Leave the house immediately and make sure your family and pets leave also.
• Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire
department.
• Stay away from the house (or building) until the service call has been made, the leak is corrected and a
qualified agency has determined the area to be safe.
Follow the steps listed under “WHAT TO DO IF YOU SMELL GAS” found on Page 3 of this manual.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion,
electric shock, or to prevent property damage, personal injury, or loss of life.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
8
www.camplux.com
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or
horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon capacity, a
brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 400
P Street, Sacramento, CA 95814 or you may call 916-445-8100 or ask a water heater dealer.
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater
than 52 gallons or tankless style, consult the local building jurisdiction code for acceptable bracing procedures.
SAFETY PRECAUTIONS
Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary. Turn off
the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or
if the gas supply fails to shut off.
• Read this manual entirely before installing or operating the water heater.
• Use this water heater only for its intended purpose as described in this Use and Care Manual.
• Be sure your water heater is properly installed in accordance with local codes and the provided installation
instructions.
• Part of your water heater unless it is specifically recommended in this manual. All other servicing should be
referred to a qualified technician.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY .
SAVE THESE INSTRUCTIONS
This water heater must be installed in accordance with these instructions, local codes, utility company require-
ments, and/or in the absence of local codes, use the latest edition of the American National Standard/National
Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 North Capitol Street
Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Battery-
march Park, Quincy, MA 02269 as NFPA 54. In Canada, the latest edition of the CSA B149.1 Natural Gas and
Propane Installation, and the Canadian Electrical Code, CSA C22.1Part1, in the absence of local codes.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
9
INSTALLING THE WATER HEATER
Indoor Location
Proper operation of the water heater requires air for combustion and ventilation. Provisionsfor combustion and
ventilation air must comply with referenced codes and standards.
• Installation distances may vary by local code. It is the installer’s responsibility to verify installation
requirements.
• Make sure before installation that the gas type you will use is the same type on the data plate.
• The water heater unit should be installed by professionals. Improper installation may cause failure or
dangerous conditions such as gas leaking or explosion.
• Water heater cannot be installed in an UN-VENTED bathroom, bedroom, basement, living room, closet,
outdoor, stairway or an exit area. If installed in an exit area, it must be at least 16.5 ft. or more away from the
exit.
• Vent pipe should extend from the wall at least 2”. The terminal must be at least 1.64 ft. away from
obstruction, and must be well vented.
• Vent pipe should slope 3° downward, to avoid condensing water and protect from rain entering.
• Vent pipe should avoid direct, strong wind because the downdraft will cause malfunction.
• The water heater should be installed far from any blockage, and with plenty of enough space for installation
and maintenance. Adequate clearances for servicing must be provided.
• The water heater should not be installed in the same room with a gas stove .
• When determining the floor clearance, a clearance of 6” must be maintained between the vent pipe and
combustible material. A side wall clearance of 6” and a top clearance of 12” must be maintained.
• The vent pipe can be up to 32 ft. in length with one elbow.
• The power socket connecting the water heater should be grounded properly with a GFCI circuit protector.
• The water heater should not be located in an area where leakage of the heat exchanger or connections will
result in damage to the area adjacent to it or to lower floors of the structure.When such areas cannot be
avoided it is recommended that a suitable catch pan, adequately drained, must be installed under the water
heater. The pan must not restrict combustion airflow.
• The water heater should be installed as close as practical to the vent termination to minimize vent length and
the number of elbows required for venting.
• A gas fired water heater or any other appliance should not be installed in a space where liquids which give off
flammable vapors are to be used or stored. Such liquids include gasoline, propane gas (butane or propane),
paint or adhesives and their thinners, solvents or removers.
• The water heater should be installed far from heat sources, flammable and dangerous materials. Because of
natural air movement in a room or other enclosed space, flammable vapors can be carried some distance
from where their liquids are being used or stored. The open flame of the water heater’s main burner can
ignite these vapors causing an explosion or fire which may result in severe burns, death or property damage.
• Raising the water heater will reduce, but not eliminate the possibility of lighting the vapor of any flammable
liquids which may be improperly stored or accidentally spilled .
• If the water heater is installed in a garage, it should be installed so that the direct ignition system and main
burner are no less than 18” above the garage floor.
• Hot and cold water lines should be insulated to conserve water and energy.
• The water heater must be located so it is not subject to physical damage, for example, by moving vehicles,
area flooding, etc.
• For other than a direct vent appliance, the appliance must be located as close as practicable to a chimney or
gas vent.
• DO NOT install water heater where subject to vibrations. or on the road use
• DO NOT install the water heater in Recreational Vehicles, Mobile Homes, Boats and other Watercraft.
• DO NOT install the water heater near vents for heating or cooling. A minimum of 4 feet should be
maintained.
• If the clearances stated on the Instruction/Warning Label, located on the front panel of the heater differ,
install the water heater according to the clearances stated on the manual.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
10
www.camplux.com
WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused
with combustible or flammable products and materials. Combustible and or flammable products and materials
should never be stored in the vicinity of this or any gas appliance.
Combustion and Ventilation Air
A confined space is one having a volume of less than 50 cubic feet per 1,000 BTU/Hr of the aggregate input of
all appliances within that space.
The air must be supplied through two permanent openings of equal area. One is to be located within 12”
above the floor and the other is to be located within 12” below the ceiling.
The minimum net free area of each opening must not be less than one square inch per 1,000 BTU/Hr of the
total input rating of all the appliances in the enclosure (but not less than 100 square inches), if each opening
communicates with other unconfined areas inside the building.
Buildings of unusually tight construction shall have the combustion and ventilation air supplied from outdoors,
or a freely ventilated attic or crawl space.
If air is supplied from outdoors, directly or through vertical ducts, there must be two openings located as
specified above and each must have a minimum net free area of not less than one square inch per 4,000
BTU/Hr of the total input rating of all the appliances in the enclosure.
If horizontal ducts are used to communicate with the outdoors, each opening must have a minimum net free
area of not less than one square inch per 2,000 BTU/Hr of the total input rating of all the appliances in the
enclosure. If ducts are used, the minimum dimensions of rectangular air ducts shall not be less than 4”.
NOTICE: If the water heater is installed in an unconfined space within a building of conventional frame,
masonry or metal construction, infiltration air is normally adequate for proper combustion and ventilation. If
the water heater is installed in a confined space, provisions for combustion and ventilation air must be made.
NOTICE: If the duct openings which supply combustion and ventilation air are to be covered with a protective
screen or grill, the net free area (openings in the material) of the covering material must be used in determin-
ing the size of the openings. Protective screening for the openings MUST NOT be smaller than 1/4” to prevent
clogging by lint or other debris.
Corrosive Atmospheres
The air in beauty shops, dry cleaning establishments, photo processing labs, and storage areas for liquid and
powdered bleaches or swimming pool chemicals often contain such
An air supply containing halogenated hydrocarbons may be safe to breathe, but when it passes through a gas
flame corrosive elements are released that will shorten the life of any gas burning halogenated hydrocarbons
appliance.
Propellants from common spray cans or gas leaks from A/ C and refrigeration equipment are highly corrosive
after passing through a flame.
The water heater warranty is voided when failure of the water heater is due to operation in a corrosive atmo-
sphere.
NOTICE: The water heater should not be installed near an any air supply containing halogenated
hydrocarbons.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
11
www.camplux.com
Check the Unit
Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be
certain the type of gas supplied corresponds to the water heater requirements. Verify all included parts are
present (see below).
INSTALLING THE WATER HEATER
Typical Installation ( Some Items May Not Apply)
Vent Adapter*
1/4 ‘’ Per Feet Downward Slope
Wall Thimble*
Manual Gas Appliance
Shut Off (Supplied)
Thermination*
Control Panel
Gas Supply Line
Remote Control (Sold Separately)
Discharge Line
(To Suitable Drain)
Drain Valve
Pressure Relief
Valve(Not Supplied)
To Hot Water
Faucet(s)
Expansion Tank
(If Needed)
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
12
WATER SUPPLY CONNECTIONS
Plumbing should be carried out by a qualified plumber in accordance with local codes. Use approveplumbing
materials and tools only.
Install a check valve between the water heater and the water shutoff valve. (See illustration below).
To conserve energy and to prevent freezing, insulate both cold and hot water supply lines. DO NOT cover the
drain valves.
Install a shutoff valve near the inlet of the water heater for service and draining purposes. Before connecting
the water supply pipe to the water heater, open the shutoff valve ·and clean out sand, debris, air, caulking
material, etc. inside the pipe. Connect to the water inlet, then check water flow. Close the shutoff valve and
clean the water filter.
If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the
cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or
local plumbing inspector on how to control this situation.
CAUTION
This water heater must only be used with the following water supply system conditions:
• With clean, potable water free of corrosive chemicals, sand, dirt, or other contaminates.
• With inlet water temperatures above 32°F, but not to exceed 90°F.
• Free of lime and scale deposits.
• DO NOT reverse the hot and cold water connections. The water heater will not operate.
To ensure proper operation of the water heater, the following water pressure guidelines should be followed:
• Operation of the water heater requires the minimum water pressure of 14 PSI and a minimum water flow rate
of 0.8 GPM.
• Additional water pressure is required for long pipe runs and outlet fitting(s) water pressure drops.
• To maintain proper performance, ensure sufficient water supply pressure. The Required Water Pressure=Min.
Operating Water Pressure (14 PSI) + Pipe Pressure Loss + Faucet and Shower Pressure Loss + Safety Margin
(more than 5 PSI).
• To supply hot water to upper floors, additional water pressure (0.44 PSI/ft) must be ensured. The
measurement should be calculated by the distance between the water inlet of the water heater (ground level)
to the hot water faucet (upper floor level).
• Well water systems should be set at a range of 50-60 PSI.
• When the water is supplied from a water supply tank, the height of the tank and the diameter of the pipes
and their relation to water pressure, should be taken into consideration. Gravity water pressure is not recom
mended.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
In Regards to the Hot Water Outlet
Connections between the water heater and point(s) of use should be as short and direct as possible.
DO NOT use lead or non-approved plastic pipe.
To conserve energy and minimize heat loss, insulation of hot water piping is recommended.
NOTICE: The flow rate of hot water many vary when more than two faucets (appliances, fixtures, etc) are being
used simultaneously.
NOTICE: The pipes MUST be completely drainable. If the hot water faucets are located at a point higher than
the water heater, place a drain valve at the lowest point (see diagram to the left).
www.camplux.com
13
IMPORTANT: Do not apply heat to the HOT or COLD water connections. Any heat applied to the water supply
fittings will permanently damage the internal components of the water heater.
NOTICE: If the water flow resistance of a shower head is too high, the burner in the water heater will fail to
ignite. Keep the shower head clean from debris that could cause additional pressure drop.
NOTICE:If using mixing valves on the outlet, choose one which prevents cold water pressure from overcoming
hot water line pressure.
DO NOT use pipes with smaller diameters than the water supply connection of the water heater.
Be sure to connect the water inlet and the hot water outlet as shown on the water heater. If reversed, the water
heater will not function.
Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines, so
that the water heater may disconnect easily for servicing if necessary.
Hot Water Tap
Drain Valve
Water Outlet
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
14
GAS SUPPLY
WARNING: Do not attempt to convert this water heater for use with a different type of gas other than
the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Please
have a professional connect the gas pipe.
The supplied Manual Gas Appliance Shut Off Valve must be installed at the gas connection of the water heater
at the time of installation.
The branch gas supply line to the water heater should ben clean black steel pipe or other approved gas piping
material.
A ground joint union or ANSI design certified semi-rigid or flexible gas appliance connector should be installe-
din the gas line close to the water heater.
The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See (NFGC) for complete instruc-
tions.
A sediment trap should be installed at the bottom of the gas line.
The inlet gas pressure to the water heater must not exceed 10.5“ w.c. for natural or 14” w.c. for propane gas.
For purposes of input adjustment, the minimum inlet gas pressure (with main burner on) is shown on the water
heater rating plate. If high or low gas pressures are present, contact your gas supplier for correction.
The water heater and its indivdual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ PSI (3.5 kPa). The water heater must
be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pres-
sure testing of the gas supply piping system at test pressures equal to or less than ½ PSI (3.5 kPa).
DO NOT use excessive force (over 31.5 ft lbs.) in tightening the pipe, particularly if pipe compound is used, as
the unit may be damaged.
Compound used on the threaded joints of the gas piping must be of the type resistant to the action of
propane gas. Use compound sparingly and use on male threads only.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
15
RELIEF VALVE
A new pressure relief valve, complying with the Standard for relief Valves and Automatic Gas Shut-Off Devices
for Hot Water Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of the water
heater at the time of installation. Local codes shall govern the installation of relief valves.
For safe operation of the water heater, be sure that:
• The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water
heater as marked on the rating plate.
• The BTU/Hr rating of the relief valve must equal or exceed the BTU/Hr input of the water heater as marked on
its rating plate.
• No valve of any type should be installed between the relief valve and the water heater.
• Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage.
Piping used should be of a type approved for the distribution of hot water.
• Hot and cold water lines should be insulated up to the water heater.
• The discharge line must be NO SMALLER than the outlet of the valve and must pitch downward to allow
complete drainage (by gravity) of the relief valve and discharge line.
• The end of the discharge line should not be threaded or concealed and should be protected from freezing.
No valve of any type, restriction or reducer coupling should be installed in discharge line.
NOTICE
The diagram below illustrates a pressure only relief valve. If local codes require a combination temperature and
pressure relief valve be installed, an extension piece may be needed.
Local codes govern the installation of relief valves. If local codes require that a temperature and pressure relief
valve should be installed the manufacturer recommends atype 40XL Watts T&P relief valve or an equivalent
model be used.
Manual operation of relief valves should be performed at least once a year. Turn off the electrical power
and gas shutoff valve. Lift and release lever on the relief valve and check the manual operation of the relief
valve.
You should take precaution to avoid contact with the hot water coming out of the relief valve and to prevent
water damage.
If the relief valve on the system discharges periodically, this may be due to thermal expansion in a closed water
supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not
plug the relief valve.
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
16
www.camplux.com
Leak Testing
WARNING: Never use an open flame to test for gas leaks, as property damage, personal injury, or death
could result.
The water heater and its gas connections must be leak tested at normal operating pressures before it is placed
in operation.
• Turn on the gas shut-off valve(s) to the water heater.
• Use a commercial leak detector or soapy water solution to test for leaks at all connections and fittings.
Bubbles indicate a gas leak that must be corrected.
All connections should also be leak tested after the water heater is placed in operation.
Pressure Testing the Gas Supply System
WARNING: Install a gas pressure regulator, in the gas supply line, which does not exceed the maximum
supply pressure. DO NOT use an industrial type gas regulator.
The water heater must be isolated from the gas piping system by closing the manual gas shut-off valve during
any pressure testing of the gas supply piping at pressures equal to or less than 1/2 PSI (14’w.c.) .
High Altitude
Ratings of gas appliances are based on sea level operation and need not be changed for installations at
elevations up to 2,000 feet / 600 meter. Unit not recommended for elevations in excess of 2,000 feet / 600
meter.
DANGER: Failure to install the vent adapter and properly vent the water heater to the outdoors as
outlined in the Venting section of this manual will result in unsafe operation of the water heater causing death,
serious injury, explosion, or fire. To avoid the risk of fire, explosion,or asphyxiation from carbon monoxide,
NEVER operate the water heater unless it is properly vented and has adequate air supply for proper operation
as outlined in the Venting section of this manual.
WARNING: Use UL approved Category III Stainless Steel vent material only. No other vent material is
permitted. Owner must refer to vent manufacturer’s instructions and specifications.
WARNING: Refer to pages 17-18 for clearances to combustible material.
Venting
The installation of venting must comply with national codes, local codes, and the vent manufacturer’s
instructions. Owner must refer to vent manufacturer’s instructions and specifications. Please visit a local
hardware store or online marketplaces to purchase φ3” Category III Stainless Steel Venting for certified
installation.
The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this
water heater to an existing Vent or Chimney, it must be vented separately from all other appliances.
All vent components (adapters, pipe, elbows, terminals, etc.) should be UL 1738 Certified Stainless Steel
Venting Material (e.g. AL29-4C).
The specified vent termination must be used. The termination should be a 90° elbow type with screen. (Refer to
page 18).
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
17
Use a vent pipe with an antidisconnection structure.
The use of a High Temperature Silicone (500°F) may be required to seal vent connections. To prevent acciden-
tal gas exhaust leakage, apply a 1/4” wide bead approximately 1/4” from the end and another bead against the
joint side of the stop bead.
Follow vent manufacturer’s installation instructions.
The unit can be vented either horizontally or vertically.
Vent pipe runs must be adequately supported along both horizontal and vertical runs.
The maximum recommended unsupported span should be no more than 5 feet. Support isolation hanging
bands should be used. DO NOT use wire. (See diagram below).
Venting Through Closed Spaces
If the vent piping passes through a closed space, wrap the vent pipe with inflammable insulation material that
is at least 3/4” thick. DO NOT let the insulation material make contact with flammable materials. A minimum
clearance of 6” between the vent pipe and ceiling should be maintained. Follow local codes.
For maintenance and inspection purposes, the following holes are required to be made:
• Two (2) inspection openings that allow access to venting. One (1) of these openings should be close to
where the vent pipe enters the ceiling. The other opening should be near the vent termination.
• A ventilation hole with a 16 sq. in. opening should be made at least every 10 feet.
NOTICE : Vent pipes must be completely insulated with inflammable material when installed in alcoves,
closets, and garages and must not touch any flammable material.
1/4” Per Feet
Downward Slope
Ceiling
Board
Inspection
Hole#2
Insulation
Material
Insulation
Material
Inspection
Hole#1
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
www.camplux.com
18
VENTING LENGTHS
Maximum Vent Length
Owner must refer to vent manufacturer’s instructions and specifications.
The system will not operate if there is excessive restriction (pressure drop) in the venting system. A maximum
of 32 feet of vent pipe may be used provided there is only one 90° elbow in the system. If additional elbows are
required: two elbows can be used with 27 feet, and three elbows can be used with 22 feet of vent pipe.
A 90° elbow is equivalent to 5 feet of straight pipe. A 45° elbow is equivalent to 2 feet 6 ” of straight pipe.
The termination elbow does not count as an elbow when determining total vent lengths.
The vent must be installed with a slight downward slope of 1/ 4” per feet of horizontal run toward the vent
terminal (see diagram below). This ensures that any condensate formed during operation of the unit is
evacuated from the water heater.
A 1/4” per feet upward slope is acceptable when it is not possible to vent with a downward slope, however, a
UL approved Category III Stainless Steel condensate trap MUST be installed at the beginning of the horizontal
run (See page 20 “Typical Horizontal Termination w/ 1/4” per foot UPWARD Slope” or page 18, “Standard
Vertical Vent Termination” for examples).
MINIMUM VENT LENGTH
The venting may be as short as 12”, provided one vent termination is installed to the outdoors through a
sidewall, one 90° elbow is included in the installation, and the wall thimble is installed.
NOTICE: Make sure that the seam of the vent pipe in horizontal runs is toward the top of the installation (see
illustration to the left)
Draining the Condensate
In certain conditions, installations in unconditioned space or having long horizontal or vertical runs may
accumulate condensate.
Condensate is known to be acidic; refer to local, state (provincial) or federal codes for proper handling
methods.
In order to prevent condensate from draining back into the water heater, we recommend a condensate trap
and drain to be installed in a horizontal vent section as close as practical to the water heater vent connection.
Not following proper condensate procedures will void warranty.
Vent Seam
More Than 6”
Number of 90°
elbows(Bends)
One(1)90° elbow is equivalent to 5
feet of straight pipe
Maximum length
of straight pipe
1 32”
27“
22”
2
2
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
19
www.camplux.com
VENT TERMINATION CLEARANCES DRAWING
For Non-Direct Vent Installations In The US And Canada
US Installation 1
Clearance above grade,veranda,
porch,deck,or balcony
Clearance to window or door
that may be opened
4ft (1.2m) below or to side of
opening;1ft (300mm) above
opening
3ft (91cm) within a height 15ft
above the meter /regulator
assembly

/Hr (3kW),12 in (30cm) for appliances

Btu/Hr (30kW), 36 in (91cm) for
appliance 10,000 Btu/Hr(30kW)

/Hr (3kW),12 in (30cm) for appliances

Btu/Hr (30kW), 36 in (91cm) for
appliance 10,000 Btu/Hr(30kW)
4ft (1.2m) below or to side of
opening: 1ft (300mm) above
opening
3ft (91cm ) above if within 10ft
(3m) horizontally
Clearance to permanently closed
window
Vertical clearance to ventilated
soffit located above the terminal
within a horizontal distance of 2
feet (61cm) from the center line
in terminal
Clearance to unventilated soffit
Clearance to outside corner
Clearance to inside corner
Clearance to each side of center
line extended above meter/
regulator assembly
Clearance to service regulator
vent outlet
Clearance to non-mechanical air
supply inlet to building or the
combustion air inlet to any other
appliance
Clearance to mechanical air supply
inlet
Clearance above pave sidewalk or
paved driveway located on public
property
Clearance under veranda,porch,
deck or balcony
Canadian Installation 2
12 in (30 cm) 12 in (30 cm)
12 in (30 cm)
7 ft (2.13 m)
6 ft (1.83 m)
3 ft (91 cm)
A=
B=
C=
D=
E=
F=
G=
H=
I=
J=
K=
L=
M=
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Camplux CA528G-LP Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues