Fujitsu UTY-VDGU Guide d'installation

Catégorie
Climatiseurs split-system
Taper
Guide d'installation
PART No. 9381279029-02
English
INSTALLATION MANUAL
DX-kit
For authorized service personnel only.
UTY-VDGU
UTP-VU30A
UTP-VU60A
UTP-VU90A
TM
FrançaisEspañol
MANUEL D’INSTALLATION
MANUAL DE INSTALACIÓN
Kit interface batterie
Kit conexión UTA
Pour le personnel agréé uniquement.
Únicamente para personal de servicio autorizado.
9381279029-02_IM.indb i9381279029-02_IM.indb i 02/10/2019 13:24:0202/10/2019 13:24:02
En-1
1. SAFETY PRECAUTIONS
• Be sure to read this Manual thoroughly before installation.
• The warnings and precautions indicated in this Manual contain important information
pertaining to your safety. Be sure to observe them.
• Hand this Manual, to the customer. Request the customer to keep them on hand for
future use, such as for relocating or repairing the unit.
• For installation of the air handling unit (heat exchanger), refer to the installation manual
for the air handling unit.
WARNING
This mark indicates procedures which, if improperly per-
formed, might lead to the death or serious injury of the user.
Request your dealer or a professional installer to install the DX-kit in accordance with
this installation manual. An improperly installed unit can cause serious accidents such
as water leakage, electric shock, or fire. If the DX-kit is installed in disregard of the
instructions in the installation manual, it will void the manufacturer’s warranty.
Do not turn ON the power until all work has been completed. Turning ON the power
before the work is completed can cause serious accidents such as electric shock or fire.
If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant
comes in contact with a flame, it produces a toxic gas.
Installation work must be performed in accordance with national wiring standards by
authorized personnel only.
Except for EMERGENCY, never turn off main as well as sub breaker of the DX-kits
during operation. It will cause compressor failure as well as water leakage. First, stop
the DX-kit by operating the control unit, converter or external input device and then cut
the breaker.
Make sure to operate through the control unit, converter or external input device.
When the breaker is designed, locate it at a place where the users cannot start and stop
in the daily work.
CAUTION
This mark indicates procedures which, if improperly performed,
might possibly result in personal harm to the user, or damage to
property.
Read carefully all security information before use or install the DX-kit.
Do not attempt to install the DX-kit or a part of the DX-kit by yourself.
This unit must be installed by qualified personnel with a capacity certificate for handling
refrigerant fluids. Refer to regulation and laws in use on installation place.
Th
e installation must be carried out in compliance with regulations in force
in the place
of installation and the installation instructions of the manufacturer.
This unit is part of a set constituting the DX-kit. It must not be installed alone or with non-
authorized by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 1/8 in (3 mm) for this unit.
The unit must be correctly earthed (grounded) and the supply line must be equipped with
a differential breaker in order to protect the persons.
The units are not explosion proof and therefore should not be installed in explosive
atmosphere.
Never touch electrical components immediately after the power supply has been turned
off. Electric shock may occur. After turning off the power, always wait 5 minutes before
touching electrical components.
This unit contains no user-serviceable parts. Always consult authorized service person-
nel to repairs.
When moving, consult authorized service personnel for disconnection and installation of
the unit.
2. ABOUT THIS PRODUCT
2.1. Precautions for using R410A refrigerant
WARNING
Do not introduce any substance other than the prescribed refrigerant into the refrigera-
tion cycle. If air enters the refrigeration cycle, the pressure in the refrigeration cycle will
become abnormally high and cause the piping to rupture.
If there is a refrigerant leak, make sure that it does not exceed the concentration limit.
If a refrigerant leak exceeds the concentration limit, it can lead to accidents such as
oxygen starvation.
Do not touch refrigerant that has leaked from the refrigerant pipe connections or other
area. Touching the refrigerant directly can cause frostbite.
If a refrigerant leak occurs during operation, immediately vacate the premises and thor-
oughly ventilate the area. If the refrigerant comes in contact with a flame, it produces a
toxic gas.
2.2. Special tool for R410A
WARNING
To install a unit that uses R410A refrigerant, use dedicated tools and piping materi-
als that have been manufactured specifically for R410A use. Because the pressure of
R410A refrigerant is approximately 1.6 times higher than the R22, failure to use dedi-
cated piping material or improper installation can cause rupture or injury.
Furthermore, it can cause serious accidents such as water leakage, electric shock, or
fire.
Tool name Changes
Gauge
manifold
The pressure in the refrigerant system is extremely high and cannot be
measured with a conventional gauge. To prevent erroneous mixing of
other refrigerants, the diameter of each port has been changed. It is rec-
ommended to use a gauge manifold with a high-pressure display range
of 500 microns to 768 psi (–0.1 to 5.3 MPa) and a low-pressure display
range of 500 microns to 551 psi (–0.1 to 3.8 MPa).
Charging
hose
To increase pressure resistance, the hose material and base size were
changed.
Vacuum
pump
A conventional vacuum pump can be used by installing a vacuum pump
adapter.
Be sure that the pump oil does not back flow into the system. Use one
capable for vacuum suction of 500 microns (–100.7 kPa).
Gas leakage
detector
Special gas leakage detector for R410A refrigerant.
2.3. Accessories
WARNING
For installation purposes, be sure to use the parts supplied by the manufacturer or other
prescribed parts. The use of non-prescribed parts can cause serious accidents such as
the unit falling, water leakage, electric shock, or fire.
The following installation parts are furnished. Use them as required.
Keep the installation manual in a safe place and do not discard any other accessories
until the installation work has been completed.
INSTALLATION MANUAL
PART No. 9381279029-02
VRF system DX-kit
Contents
1. SAFETY PRECAUTIONS .............................................................................................1
2. ABOUT THIS PRODUCT ..............................................................................................1
2.1. Precautions for using R410A refrigerant .............................................................1
2.2. Special tool for R410A ........................................................................................1
2.3. Accessories ........................................................................................................1
2.4. Optional parts .....................................................................................................2
2.5. About unit of the length .......................................................................................2
3. PRODUCT SELECTION ...............................................................................................3
3.1. Product Lineup ...................................................................................................3
3.2. System Design ...................................................................................................3
4. INSTALLATION WORK ................................................................................................3
4.1. Selecting an installation location ........................................................................3
4.2. Installation dimensions .......................................................................................4
4.3. Installing the unit .................................................................................................4
5. PIPE INSTALLATION ...................................................................................................5
5.1. Selecting the pipe material .................................................................................5
5.2. Pipe requirement ................................................................................................5
5.3. Bending pipes .....................................................................................................6
5.4. Pipe connection ..................................................................................................6
5.5. Installing heat insulation .....................................................................................6
6. MOUNTING THERMISTORS ........................................................................................6
7. ELECTRICAL WIRING .................................................................................................7
7.1. Electrical requirement .........................................................................................7
7.2. Wiring method ....................................................................................................7
7.3. Unit wiring ...........................................................................................................8
7.4. Connection of wiring ...........................................................................................9
7.5. External input and external output (Optional parts) ..........................................10
8. FIELD SETTING ..........................................................................................................13
8.1. Setting the address ...........................................................................................13
8.2. Dip switch setting ..............................................................................................14
8.3. Function setting ................................................................................................14
9. TEST RUN ...................................................................................................................15
9.1. Test run using Outdoor unit (PCB) ....................................................................15
9.2. Test run using remote controller .......................................................................15
10. CHECK LIST (Example) ...........................................................................................15
11. ERROR CODES ........................................................................................................15
12. OPERATIONS ...........................................................................................................16
12.1. Analog external inputs ....................................................................................16
9381279029-02_IM.indb 19381279029-02_IM.indb 1 02/10/2019 13:24:0202/10/2019 13:24:02
En-2
2.3.1. Control unit Accessories
Name and Shape Q’ty Application
Installation
manual
1
(This book)
Key
2
For the door of control unit
Sealing washer
3
For mounting the control unit to the wall
Waterproof specifications
Nuts (M8)
3
For mounting the control unit to the wall
Cable ties (with
stopper)
1
For securing the cables
Cable tie
3
For securing the optional remote
controller cable
Hole plug
6
For closing unused conduit holes on the
Control unit
Screw
(M4 × L6 mm)
3
For mounting the optional remote
controller
Cable tie mount
2
For securing the optional remote
controller cable
Thermistor
(Inlet air and outlet
air)
2
For measuring the room temperature
Thermistor
(Label: GAS)
1
For measuring the gas pipe tempera-
ture
(For gas pipes)
Thermistor
(Label: LIQ)
1
For measuring the liquid pipe tem-
perature
(For liquid pipes)
Thermistor holder
pipe (Small)
1
For mounting the thermistor
Thermistor holder
pipe (Large)
1
For mounting the thermistor
Thermistor spring
(For small therm-
istor holder pipe)
1
For mounting the thermistor
Thermistor spring
(For large thermis-
tor holder pipe)
1
For mounting the thermistor
Template
1
For installing the control unit
Connection cable 1
[Label: 32,33,35,37,39,41]
1
For external output
Connection cable 2 [Label: 32,34]
1
For external output
Connection cable 3 [Label: 34,36]
1
For external output
Connection cable 4 [Label: 36,38]
1
For external output
Connection cable 5 [Label: 38,40]
1
For external output
2.3.2. EEV unit Accessories
Name and Shape Q’ty Application
Installation manual
1
Secure fitting
4
For mounting the EEV unit to the wall,
or stacking multiple EEV units
Tapping Screw L
(M4 × L16 mm)
8
For mounting the EEV unit to the wall
Tapping Screw S
(M4 × L10 mm)
8 For stacking multiple EEV unit
3 For fixing the conduit plate
Rubber sheet
2
For mounting pipe joints
Pipe heat insula-
tions
2
For mounting pipe joints
Cable tie (Large)
4
For securing heat insulations
Conduit plate
1
For connecting the conduit
Seal
2
For pasting unused piping holes
2.4. Optional parts
Connectable Peripheral Devices
Model Name Notes
System controller UTY-APGXZ1, UTY-APGX (*2)
System controller lite UTY-ALGXZ1, UTY-ALGX (*2)
Touch panel controller UTY-DTGYZ1, UTY-DTGY (*2)
Central remote controller UTY-DCGY (*2)
Wired remote controller UTY-RNRUZ*, UTY-RNRU (*1, *2)
Wired remote controller UTY-RNKU (*1, *2)
Simple remote controller UTY-RSRY, UTY-RSKU (*1, *2)
Simple remote controller UTY-RHRY, UTY-RHKU (*1, *2)
Wireless remote controller
(via IR receiver unit)
UTY-LNHU
(UTB-YWC)
(*2)
Network convertor for LONWORKS® UTY-VLGX (*2)
MODBUS® convertor for VRF UTY-VMGX (*2)
BACnet® Gateway
UTY-VBGX, UTY-ABGXZ1,
UTY-ABGX
(*2)
Service tool UTY-ASGXZ1, UTY-ASGX (*2)
Web monitoring tool UTY-AMGXZ1, UTY-AMGX (*2)
Separation tube (for EEV unit 2 connections) UTP-LX180A
*1: Remote controller groups cannot be connected using DX-kits or other indoor units.
*2: If controlling using “external input and output” analog inputs from an external control-
ler (DDC), operations from the controllers described above are disabled.
2.5. About unit of the length
This product is manufactured to metric units and tolerances. United States customary
units are provided for reference only. In cases where exact dimensions and tolerances are
required, always refer to metric units.
9381279029-02_IM.indb 29381279029-02_IM.indb 2 02/10/2019 13:24:0202/10/2019 13:24:02
En-3
3. PRODUCT SELECTION
• Failure to observe the selection conditions described below will affect the outdoor unit
service life and operational reliability.
• When selecting air handling unit, it must be designed for R410A refrigeration.
3.1. Product Lineup
3.1.1. Product Lineup
Unit Name Model Name Environment specifications
Control unit UTY-VDGU
• Temperature: -4.0 to 114.8 °F (-20 to 46 °C)
• Humidity: 10 to 90% RH (No condensation)
EEV unit
UTP-VU30A
UTP-VU60A
UTP-VU90A
3.1.2. EEV unit Selection
• The EEV unit is selected according to the capacity class conditions.
If the capacity class is 144 kBTU/h (40.0 kW) or 180 kBTU/h (50.0 kW), 2 EEV units are
connected (in parallel).
Capacity Class
[kBTU/h]
18 24 30 36 48 60 72 96 144 180
EEV unit model No. 30 60 90 90 + 90
Cooling capacity
[kBTU/h (kW)]
18
(5.3)
24
(7.0)
30
(8.8)
36
(10.6)
48
(14.1)
60
(17.6)
72
(21.1)
96
(28.1)
144
(42.2)
168
(49.2)
Heating capacity
[kBTU/h (kW)]
20
(5.9)
27
(7.9)
34
(10.0)
40
(11.7)
54
(15.8)
67
(19.6)
81
(23.7)
108
(31.7)
162
(47.5)
188
(55.1)
Heat exchanger
capacity
Refer to the Design & Technical manual.
Airflow rate
(Reference)
[CFM (m³/h)]
624
(1,060)
706
(1,200)
895
(1,520)
941
(1,600)
1,177
(2,000)
1,318
(2,240)
2,095
(3,560)
2,354
(4,000)
3,767
(6,400)
4,709
(8,000)
Capacity
range
[kBTU/h
(kW)]
Cooling
14 to
18
18.1
to 24
24.1
to 30
30.1
to 36
36.1
to 48
48.1
to 60
60.1
to 72
72.1
to 96
96.1
to 144
144.1
to 168
(4.1 to
5.3)
(5.4 to
7.0)
(7.1 to
8.8)
(8.9 to
10.6)
(10.7 to
14.1)
(14.2 to
17.6)
(17.7 to
21.1)
(21.2 to
28.1)
(28.2 to
42.2)
(42.3 to
49.2)
Heating
15.6
to 20
20.1
to 27
27.1
to 34
34.1
to 40
40.1
to 54
54.1
to 67
67.1
to 81
81.1
to 108
108.1
to 162
162.1
to 188
(4.6 to
5.9)
(6.0 to
7.9)
(8.0 to
10.0)
(10.1 to
11.7)
(11.8 to
15.8)
(15.9 to
19.6)
(19.7 to
23.7)
(23.8 to
31.7)
(31.8 to
47.5)
(47.6 to
55.1)
Evaporation tem-
perature
Refer to the Design & Technical manual.
Condensation
temperature
Refer to the Design & Technical manual.
Pipe size
(b)
(a)
(c)
(c)
(b)
(b)
(c)
(a)
(c)
(b)
Heat
Exchanger
Heat
Exchanger
Gas pipe Gas pipe
Liquid
pipe
Liquid
pipe
EEV
unit
EEV
unit
Capacity Class
[kBTU/h (kW)]
18
(5.0)
24
(6.3)
30
(8.0)
36
(10.0)
48
(12.5)
60
(14.0)
72
(20.0)
96
(25.0)
144
(40.0)
180
(50.0)
Pipe size
[in (mm)]
(a)
Gas
5/8
(15.88)
3/4
(19.05)
7/8
(22.2)
1-1/8
(28.58)
(b)
Liquid
3/8
(9.52)
1/2
(12.70)
5/8
(15.88)
(c)
Liquid
1/2
(12.70)
Pipe length
(a)
(d)
(c)
(f)
(e)
(b)
Heat
Exchanger
Heat
Exchanger
Gas pipe Gas pipe
Liquid
pipe
Liquid
pipe
EEV
unit
EEV
unit
(a) (b) (c) (d) (e) (d) + (f) (e) + (f)
16 ft
( 5 m)
6 ft
( 2 m)
16 ft
( 5 m)
3.2. System Design
3.2.1. Basic Refrigerating System Configuration
Using the DX-kit enables
indoor units manufactured
by other than Fujitsu
general to be used in the
Fujitsu general refrigerant
system.
*1: DX-kit = Control unit
+ EEV unit
DX-kit (*1)
Outdoor unit
Indoor unit
Indoor unit Indoor unit
3.2.2. Basic DX-kit System Configuration
(1) System Pattern 1
External controllers (DDC)
not manufactured by
Fujitsu general control the
Fujitsu general outdoor
units and indoor units
(refrigerant cycle devices,
etc.) not manufactured by
Fujitsu general. With this
system, control using a
Fujitsu general VRF con-
troller is not possible.
For control line details,
see “External Input and
External Output”.
System configuration
diagram
Fujitsu general-approved devices
Outdoor unit
Indoor unit
Control unit
Liquid pipe
Gas pipe
Thermistor × 4
Wired remote
controller
External controller
not manufactured
by Fujitsu general
Control line
Piping
Wiring
EEV unit
(2) Pattern 2
Fujitsu general remote
controllers and control
devices directly control
Fujitsu general outdoor
units and indoor units
(refrigerant cycle devices,
etc.) not manufactured by
Fujitsu general. A system
configuration example is
shown below.
System Configuration
Diagram
Fujitsu general-approved devices
Outdoor unit
Indoor unit
Control unit
Liquid pipe
Gas pipe
Control line
Thermistor × 4
Wired remote
controller
Piping
Wiring
EEV unit
3.2.3. Pipe Conditions
EEV
unit
Heat
Exchanger
R
Straight pipe = 8 in
(200 mm) or more
Liquid pipe
Gas pipe
4. INSTALLATION WORK
Correct initial installation location is important because it is difficult to move unit after it is
installed.
4.1. Selecting an installation location
Decide the mounting position together with the customer as follows.
WARNING
Select installation locations that can properly support the weight of the DX-kit. Install the
units securely so that they do not topple or fall.
9381279029-02_IM.indb 39381279029-02_IM.indb 3 02/10/2019 13:24:0302/10/2019 13:24:03
En-4
4.3. Installing the unit
WARNING
Install the DX-kit in a location which can withstand a load of at least 5 times the weight
of the main unit and which will not amplify sound or vibration. If the installation location
is not strong enough, the DX-kit may fall and cause injuries.
If the job is done with the panel frame only, there is a risk that the unit will come loose.
Please take care.
Carrying in and installation of the unit should be performed by a sufficient number of
people and with sufficient equipment that is adequate for the weight of the unit. Perform-
ing such work by an insufficient number of people or with inadequate equipment could
result in dropping of the unit or personal injury.
4.3.1. Installing the Control unit
• If installing outdoors, make sure to orient A upwards.
• Using a template (accessory) is recommended when positioning the holes for mounting
the control unit.
±5° or
less
Inclination limits
Sealing washers
(×3, accessories)
M8 Nuts
(×3, accessories)
A
A
Control
unit
7-7/8 in (200 mm)
or more
Service
space
7-7/8 in (200 mm)
or more
Service
space
Rubber inside the washer is contacted
tightly with the Control unit.
anchor
bolt
Rubber Steel
4.3.2. Installing the EEV unit
4.3.2.1. Connecting the conduit
(1) Remove the 2
screws and the
cover.
(2) Connect the conduit
(locally purchased)
to the conduit plate
(accessories). Then,
pass the cable
of the EEV unit
through the conduit.
(3) Attach the conduit
plate (accessories)
with 2 tapping screw
S (accessories).
(4) Re-attach the cover
with the two screws.
(5) Fix the cover with
a tapping screw S
(accessories).
(1), (4)
(3)
(5)
(2)
Cover
Conduit plate
(accessories)
Lock nut
(included
with the
conduit)
Conduit
(locally
purchased)
4.3.2.2. Changing Pipe Orientation
EEV unit pipe orientation can be changed according to the installation conditions.
(1) Remove the cover.
When the conduit
plate (accessories)
is already attached,
remove it.
(2) Invert both the
pipes and heat
insulation.
(3) Re-attach the
conduit plate (ac-
cessories) and the
cover.
For details about
connecting the con-
duit and attaching
the conduit plate
(accessories), refer
to “4.4.1. Connect-
ing the conduit”.
(1), (3)
(1), (3)
(2)
Cover
Heat insulation
Conduit plate
(accessories)
CAUTION
Do not install the DX-kit in the following areas:
• Area with high salt content, such as at the seaside. It will deteriorate metal parts, caus-
ing the parts to fail or the unit to leak water.
• Area filled with mineral oil or containing a large amount of splashed oil or steam, such
as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit to leak
water.
• Area that generates substances that adversely affect the equipment, such as sulfuric
gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to
corrode, which can cause refrigerant leakage.
• Area that can cause combustible gas to leak, contains suspended carbon fibers or
flammable dust, or volatile flammables such as paint thinner or gasoline. If gas leaks
and settles around the unit, it can cause a fire.
• Area where animals may urinate on the unit or ammonia may be generated.
Do not use the unit for special purposes, such as storing food, raising animals, growing
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.
Do not install where there is the danger of combustible gas leakage.
Do not install the unit near a source of heat, steam, or flammable gas.
Install the DX-kit, power supply cable, transmission cable, and remote controller cable
at least 1 m away from a television or radio receivers. The purpose of this is to prevent
TV reception interference or radio noise. (Even if they are installed more than 1 m apart,
you could still receive noise under some signal conditions.)
If children under 10 years old may approach the unit, take preventive measures so that
they cannot reach the unit.
Take precautions to prevent the unit from falling.
(1) Install the DX-kit on a place having a sufficient strength so that it withstands against
the weight of the DX-kit.
(2) Leave the space required to service the DX-kit.
(3) Install the unit where connection to the outdoor unit (or RB unit) is easy.
(4) Install the unit where the connection pipe can be easily installed.
(5) Install the unit where noise and vibrations are not amplified.
(6) Take servicing, etc., into consideration and leave the spaces.
(7) Do not install the unit where it will be exposed to direct sunlight.
4.2. Installation dimensions
4.2.1. Control unit
15-3/4 (400)
4-3/4
(120)
5-1/4 (134)
12-1/16 (306)
3 × Ø3/8
(3 × Ø10)
15-3/4 (400)
9-7/8 (251)
[Unit: in (mm)]
Weight of the Control unit [lbs (kg)]
UTY-VDGU 22 (10)
4.2.2. EEV unit
8-11/16 (221)
8 (203)
6-1/4 (159)
4 × Ø7/16 (11)
8 × Ø3/16 (5)
1-1/4 (31)7/8 (22)
3-9/16 (90)
2-5/16 (58)
2-5/16
(58)
(4-3/4
(120))
(5 (127))
6-5/8 (168)
8-3/8 (212.4)
(4-21/8 (104))
1-1/8 (29.2)
7-3/16 (182)
9/16 (14)
7/8 (22.2)
(3-1/16 (78))
9-1/8 (231)
A
B
1/7/16 (36)
[Unit: in (mm)]
Connection pipe diameter [in (mm)]
Model A B Weight of the EEV unit [lbs (kg)]
UTP-VU30A 3/8 (9.52) 3/8 (9.52) UTP-VU30A 4.4 (2)
UTP-VU60A 3/8 (9.52) 3/8 (9.52) UTP-VU60A 4.4 (2)
UTP-VU90A 1/2 (12.70) 1/2 (12.70) UTP-VU90A 4.4 (2)
9381279029-02_IM.indb 49381279029-02_IM.indb 4 02/10/2019 13:24:0302/10/2019 13:24:03
En-5
Prohibited EEV unit orientations
A
AA
A
B
BB
B
PROHIBITED
5. PIPE INSTALLATION
CAUTION
Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with
refrigerant R410A models. Also, when storing the piping, securely seal the openings by
pinching, taping, etc.
While welding the pipes, be sure to blow dry nitrogen gas through them.
5.1. Selecting the pipe material
CAUTION
Do not use existing pipes from another refrigeration system or refrigerant.
Use pipes that have clean external and internal sides without any contamination which
may cause trouble during use, such as sulfur, oxide, dust, cutting waste, oil, or water.
It is necessary to use seamless copper pipes.
Material: Phosphor deoxidized seamless copper pipes
It is desirable that the amount of residual oil is less than 0.004 oz. /100 ft (40 mg /10 m).
Do not use copper pipes that have a collapsed, deformed, or discolored portion (es-
pecially on the interior surface). Otherwise, the expansion valve or capillary tube may
become blocked with contaminants.
Improper pipe selection will degrade performance. As an air conditioner using R410A
incurs pressure higher than when using conventional (R22) refrigerant, it is necessary to
choose adequate materials.
• Thicknesses of copper pipes used with R410A are as shown in the table.
• Never use copper pipes thinner than those indicated in the table even if they are avail-
able on the market.
Thicknesses of Annealed Copper Pipes (R410A)
Outside diameter [in (mm)] Wall thickness [in (mm)] (*1) Material
1/4 (6.35) 0.032 (0.80)
COPPER
JIS H3300 C1220T-O
or equivalent (*2)
3/8 (9.52) 0.032 (0.80)
1/2 (12.70) 0.032 (0.80)
5/8 (15.88) 0.039 (1.00)
3/4 (19.05) 0.047 (1.20)
7/8 (22.22) 0.039 (1.00)
COPPER
JIS H3300 C1220T-H
or equivalent (*3)
1-1/8 (28.58) 0.039 (1.00)
*1: Endurance pressure of the pipes 609 psi (4.2 MPa)
*2: Allowable tensile stress 33 N/mm²
*3: Allowable tensile stress 61 N/mm²
Please select the pipe size in accordance with local rules.
5.2. Pipe requirement
Use pipe with water-resistant heat insulation.
CAUTION
Refer to the installation manual of the outdoor unit for description of the length of con-
necting pipe or for difference of its elevation.
Install heat insulation around both the gas and liquid pipes. Failure to do so may cause
water leaks. Use heat insulation with heat resistance above 248°F (120°C). (Reverse
cycle model only)
In addition, if the humidity level at the installation location of the refrigerant piping is
expected to exceed 70 %, install heat insulation around the refrigerant piping. If the ex-
pected humidity level is 70 to 80 %, use heat insulation that is 9/16 in (15 mm) or thicker
and if the expected humidity exceeds 80 %, use heat insulation that is 13/16 in (20 mm)
or thicker. If heat insulation is used that is not as thick as specified, condensation may
form on the surface of the insulation.
In addition, use heat insulation with heat conductivity of 0.045 W/(m·K) or less (at 68°F
(20°C)).
4.3.2.3. Pasting Seals to the piping holes
Use the seals (accessories) to cover any
unused piping holes.
Seal (accessories)
Seal
(accessories)
4.3.2.4. Mounting Secure Fittings (If Using 1 EEV unit)
Use the 8 screws (accessories) to secure
the secure fittings (accessories).
Tightening torque
M4 screw
7.1 to 24.8 lbf·in
(0.8 to 2.8 N·m)
Secure fitting
(accessories)
Screws M4 × L10 mm
(accessories)
4.3.2.5. Mounting Secure Fittings (If Using 2 EEV units)
If using 2 EEV units, stacking the 2
kits is recommended.
If stacking 2 EEV units, secure us-
ing the secure fittings (accessories)
and screws (accessories).
Complete the conduit connection of
the back unit, before mounting the
front unit.
Secure fitting
(accessories)
Screws M4 × L10 mm
(accessories)
4.3.2.6. Installing EEV units
Mount the EEV unit to the wall.
Select the securing method according to the installation environment.
Method 1
Use the 8 screws (accessories) to secure
the unit.
Method 2
Mount the 4 anchor bolts (locally pur-
chased) to the wall, and then secure the
unit.
Screws M4 × L16 mm
(accessories)
Nuts and washers
(locally purchased)
Installable EEV unit orientations
A
AA
A
B
BB
B
Orient the arrow upwards
Installable both indoors and outdoors
Installable indoors only
(Cannot be installed outdoors)
EEV unit inclination limits
±10° or
less
±10° or
less
9381279029-02_IM.indb 59381279029-02_IM.indb 5 02/10/2019 13:24:0302/10/2019 13:24:03
En-6
5.3. Bending pipes
• The pipes are shaped by your hands or pipe bender. Be careful not to collapse them.
• Do not bend the pipes in an angle more than 90°.
• When pipes are repeatedly bend or stretched, the material will harden, making it difficult
to bend or stretch them anymore. Do not bend or stretch the pipes more than 3 times.
CAUTION
To prevent breaking of the pipe, avoid sharp bends.
If the pipe is bent repeatedly at the same place, it will break.
5.4. Pipe connection
CAUTION
If air or another type of refrigerant enters the refrigera-
tion cycle, the internal pressure in the refrigeration
cycle will become abnormally high and prevent the
unit from exerting its full performance.
Pressure regulating valve
Cap
Nitrogen gas
Brazing area
Apply nitrogen gas while brazing the pipes.
Nitrogen gas pressure: 2.9 psi (0.02 MPa)
(= pressure felt sufficiently on the back of your hand)
If a pipe is brazed without applying nitrogen gas, it will create an oxidation film.
This can degrade performance or damage the parts in the unit (such as the compressor
or valves).
Do not use flux to braze pipes. If the flux is the chlorine type, it will cause the pipes to
corrode.
In addition, if the flux contains fluoride, it will affect the refrigerant piping system due to
deterioration of refrigerant oil.
For brazing material, use phosphor copper that does not require flux.
Outer diameter of pipe [in (mm)]
Connection Pipe (Liquid) 1/2 (12.70)
Connect the EEV unit pipe to the connection pipe. Braze the connectors.
When brazing the piping, take measures to prevent damage to the unit and surround-
ings due to heat.
(a) Connecting 1 EEV unit
Connection pipe
(locally purchased)
Connection pipe
(locally purchased)
(b) Connecting 2 EEV units
If connecting 2 stacked EEV units, connect the special branch pipe (optional parts).
Relay pipes: Outside dimensions Ø 1/2 in
(Ø 12.7 mm) (locally purchased)
Relay pipes: Outside dimensions Ø 1/2 in
(Ø 12.7 mm) (locally purchased)
Branch pipes
(optional parts)
Branch pipes
(optional parts)
5.5. Installing heat insulation
CAUTION
After checking for gas leaks (refer to the installation manual of the outdoor unit), perform
this section. Failure to do so may cause water leaks.
Implement heat insulation as shown in the diagram below.
(1) Mount the rubber sheets (accessories).
(2) Mount the heat insulations (accessories). There should be no gaps between the
insulation and the product.
(3) Secure to a pipe using 2 cable ties.
(1) Butyl rubber sheets
(accessories)
(2) Heat insulations
(accessories)
(3) Cable ties
(Large, accessories)
No gap
• Perform the work in (1), (2) and (3) for the 2 pipes.
• For the heat insulation on the separation tube (Optional parts) used to connect 2 EEV
units, refer to the installation manual of the separation tube.
For construction other than mounting the EEV unit (e.g., mounting thermistors, electrical
wiring, and field settings, etc.), see the construction manual enclosed with the control
unit.
6. MOUNTING THERMISTORS
• To prevent water from accumulating on top of the thermistor, orient the thermistor wires
downwards when mounting the thermistor.
• Make good contact between thermistor and air handling unit. Put the top of the thermis-
tors on the air handling unit, this is the most sensitive point of the thermistor.
Mounting thermistors to general indoor units
A
C
D
B
EEV
kit
Refrigerant flow
during cooling
Air inlet
Air outlet
Heat
exchanger
General indoor unit
A: Heat exchanger inlet pipe
Braze a thermistor holder pipe (Ø 1/4 in (Ø 6.35 mm), accessories) in front of the distribu-
tor branch.
Use a thermistor spring (accessories) to tightly seal and secure the thermistor (Ø 3/16 in
(Ø 4 mm), accessories) pipes.
(1) (2)
(3)
(1)
(2)
(3)
(1) Thermistor holder pipe
(Ø 1/4 in (Ø 6.35 mm))
(2) Thermistor
(Ø 3/16 in (Ø 4 mm))
(3) Thermistor spring
Distributor
Heat
exchanger
* Attach this thermistor in a location where the evaporating temperature can be detected
during cooling operation.
B: Heat exchanger outlet pipe
Braze a thermistor holder pipe (Ø 3/8 in (Ø 9.53 mm), accessories) to the heat exchanger
outlet pipe.
Use a thermistor spring (accessories) to tightly seal and secure the thermistor (Ø 1/4 (Ø 6
mm), accessory) pipes.
9381279029-02_IM.indb 69381279029-02_IM.indb 6 02/10/2019 13:24:0402/10/2019 13:24:04
En-7
CAUTION
Earth (Ground) the unit.
Do not connect the earth (ground) cable to a gas pipe, water pipe, lightning rod, or a
telephone earth (ground) cable.
Improper earthing (grounding) may cause electric shock.
Do not connect power supply cables to the transmission or remote controller terminals,
as this will damage the product.
Never bundle the power supply cable and transmission cable, remote controller cable
together.
Separate these cables by 2 in (50 mm) or more.
Bundling these cables together will cause miss operation or breakdown.
When handling PCB, static electricity charged in the body may cause malfunction of the
PCB. Follow the cautions below:
• Establish an earth (ground) for the DX-kit and outdoor units and peripheral devices.
• Cut power (breaker) off.
• Touch metal part of the DX-kit for more than 10 seconds to discharge static electricity
charged in the body.
• Do not touch terminals of parts and patterns implemented on PCB.
7.1. Electrical requirement
• The following breaker specifications apply only to connections for Fujitsu general indoor
units, RB units, and DX-kits.
• Do not simultaneously connect Fujitsu general devices and non-Fujitsu general devices
to the same breaker. In using non-Fujitsu general devices, follow the specifications for
that device.
• Select the power cable type and size
in accordance with relevant local and
national regulations.
Voltage rating
208/230 V
Operating range
187 to 253 V
• Specifications for local wiring power cord and branch wiring are in compliance with local
code.
• Max. wire length: Set a length so that the voltage drop is less than 2%. Increase the wire
diameter when the wire length is long.
Refer to the table for the breaker specifications of each installation condition. Perform the
power crossover wiring within the range of the same refrigerant system. When the cross-
over wiring is done, make a connection for DX-kits to satisfy conditions A and B below.
A. Current breaker requirements
Model MCA
MAX. CKT. BKR
(Fuse capacity)
UTY-VDGU 0.096 A
20 A
MCA: Minimum Circuit Ampacity
MAX. CKT. BKR: Maximum Circuit
Breaker
When the power crossover wiring is done, make it so that the total of the MCA of the con-
nected DX-kits, RB units, and indoor units does not exceed the 15 A. For indoor unit MCA
and RB unit MCA, refer to the indoor unit and RB unit installation manual.
If the capacity of connected DX-kits, RB units, and indoor units exceeds the upper limit,
either add breakers or use a breaker with a greater capacity.
B. Earth leakage breaker requirements
Breaker capacity
Maximum connectable DX-kits, “indoor units +
DX-kits”, or “indoor units + RB units + DX-kits” (*1)
30 mA, 0.1 sec or less 44 or less (*2)
100 mA, 0.1 sec or less 45 to 128
*1: Heat pump type: indoor units, Heat recovery type: indoor units and RB units.
*2: If the total number of units connected to the breaker exceeds 44, either add a 30 mA
breaker, or use breakers with a greater capacity.
7.1.1. Cable specifications
For cable selections, see the "Connection of wiring" chapter below.
7.2. Wiring method
EXAMPLE
(*2)
(*2)
Outdoor unit or RB unit (*1)
DX-kit (Control unit)
Transmission
X1, X2: Transmission
Y1, Y2, Y3: Remote controller
External interface
terminal (*3)
Indoor unit
Remote
controller
Remote controller
Power supply
Power supply Power supply
Breaker 2 Breaker 2
Breaker 1 Breaker 1
*2
*1: When connecting to the Heat Recovery System, refer to the installation manual of the
RB unit.
*2: When connecting the 2-wire type remote controller, Y3 is not used.
*3: For the external interface terminal, refer to "7.4. Connection of wiring".
(1)
(1)
(2)
(3)
(2)
(3)
(1) Thermistor holder pipe
(Ø 3/8 in (Ø 9.53 mm))
(2) Thermistor
(Ø 1/4 in (Ø 6 mm))
(3) Thermistor spring
Heat
exchanger
C: Inlet air thermistor/D: Outlet air thermistor
Install in a location where the effects of heat sources such as heat exchangers and heat-
ers, etc., are minimized as far as possible.
CD
Inlet air thermistor
(accessories)
Outlet air thermistor
(accessories)
Air outlet
Air inlet
General indoor unit
7. ELECTRICAL WIRING
WARNING
Electrical work must be performed in accordance with this Manual by a person certified
under the national or regional regulations. Be sure to use a dedicated circuit for the unit.
An insufficient power supply circuit or improperly performed electrical work can cause
serious accidents such as electric shock or fire.
Before starting work, check that power is not being supplied to the all units.
Use the included connection cables and power cables or ones specified by the manu-
facturer. Improper connections, insufficient insulation, or exceeding the allowable current
can cause electric shock or fire.
For wiring, use the prescribed type of cables, connect them securely, making sure that
there are no external forces of the cables applied to the terminal connections. Improp-
erly connected or secured cables can cause serious accidents such as overheating the
terminals, electric shock, or fire.
Do not modify the power cables, use extension cables, or use any branches in the wir-
ing. Improper connections, insufficient insulation, or exceeding the allowable current can
cause electric shock or fire.
Match the terminal board numbers and connection cable colors with those of the out-
door unit (or RB unit). Erroneous wiring may cause burning of the electric parts.
Securely connect the connection cables to the terminal board. In addition, secure the
cables with wiring holders. Improper connections, either in the wiring or at the ends of the
wiring, can cause a malfunction, electric shock, or fire.
Always fasten the outside covering of the connection cable with the cable clamp. (If the
insulator is chafed, electric discharge may occur.)
Securely install the electrical box cover on the unit. An improperly installed electrical box
cover can cause serious accidents such as electric shock or fire through exposure to
dust or water.
Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit
could result.
Install an earth leakage breaker. In addition, install the earth leakage breaker so that the
entire AC main power supply is cut off at the same time. Otherwise, electric shock or fire
could result.
Always connect the earth (ground) cable.
Improper earthing (grounding) work can cause electric shocks.
Install the remote controller cables so as not to be direct touched with your hand.
Perform wiring work in accordance with standards so that the DX-kit can be operated
safely and positively.
Connect the connection cable firmly to the terminal board. Imperfect installation may
cause a fire.
If the supply cable is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Take special precaution for connection to the external controller (DDC, locally pur-
chased).
Make sure the wiring for the external input and output signals is correct.
Miswiring of these cables could damage the entire system.
9381279029-02_IM.indb 79381279029-02_IM.indb 7 02/10/2019 13:24:0402/10/2019 13:24:04
En-8
DX-kit (Control unit)
Power supply
Pull box
Pull box
Breaker2
Breaker1
Power supply Power supply
Power supply
: Disconnect switch
Indoor unit Indoor unit
(Crossover wiring of power supply)
Disconnect switch shall be installed between each unit and pull box.
7.3. Unit wiring
Before attaching the cable to terminal block.
7.3.1. Power supply cable and Drain pump signal cable
Adjust the length of power supply cable to avoid excessive tension with referring figure
below.
Conduit connector
Earth (ground)
wire
5-1/2 in (140 mm)
5-1/2 in (140 mm)
Decide the peeling length of the covering for the power supply cable and the drain pump
signal cable according to the conditions for connecting to the terminal.
A. For solid core wiring
(1) To connect the electrical terminal, follow the below diagram and connect after looping
it around the end of the cable.
(2) Use the specified cables, connect them securely, and fasten them so that there is no
stress placed on the terminals.
(3) Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-
driver that is too small, otherwise, the screw heads may be damaged and prevent the
screws from being properly tightened.
(4) Do not tighten the terminal screws too much, otherwise, the screws may break.
(5) See the table for the terminal screw tightening torques.
(6) Please do not fix 2 power supply cables with 1 screw.
Strip 1 in
(25 mm)
Loop
Screw with
special washer
Screw with
special washer
Cable end
(Loop)
Cable
Cable
Terminal block
Cable end (Loop)
WARNING
When using solid core cables, do not use the ring terminal. If you use the solid core
cables with the ring terminal, the ring terminal’s pressure bonding may malfunction and
cause the cables to abnormally heat up.
B. For strand wiring
(1) Use ring terminals with insulating sleeves as shown in the figure below to connect to
the terminal block.
(2) Securely clamp the ring terminals to the cables using an appropriate tool so that the
cables do not come loose.
(3) Use the specified cables, connect them securely, and fasten them so that there is no
stress placed on the terminals.
(4) Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-
driver that is too small, otherwise, the screw heads may be damaged and prevent the
screws from being properly tightened.
(5) Do not tighten the terminal screws too much, otherwise, the screws may break.
(6) See the table for the terminal screw tightening torques.
(7) Please do not fix 2 power supply cables with 1 screw.
Sleeve
Strip 3/8 in
(10 mm)
Screw with spe-
cial washer
Screw with special
washer
Ring terminal
Cable
Terminal block
Cable
Ring terminal
Ring
terminal
WARNING
Use ring terminals and tighten the terminal screws to the specified torques, otherwise,
abnormal overheating may be produced and possibly cause heavy damage inside the
unit.
Tightening torque
M4 screw
(Power supply/L1, L2 (N), GND)
11 to 16 lbf·in
(1.2 to 1.8 N·m)
7.3.2. Transmission cable, Remote controller cable and External
interface cable
Transmission cable
Shielded cable
(no film)
1 in (25 mm)
1-9/16 in (40 mm)
Remote controller cable
For 3-wire type For 2-wire type
1 in (25 mm) 1 in (25 mm)
External interface cable
Decide the peeling length the covering for the external interface cable according to the
conditions for connecting to the terminal.
Fig. A
GOOD PROHIBITED
Different diameter Connect to 1 side
WARNING
Tighten the terminal screws to the specified torques, otherwise, abnormal overheating
may be produced and possibly cause heavy damage inside the unit.
Terminal number Tightening torque
M3 screw
(Transmission/X1, X2)
(Remote controller/ Y1, Y2, Y3)
4.4 to 5.3 lbf·in
(0.5 to 0.6 N·m)
CAUTION
To peel the film from the lead cable, use a dedicated tool that will not damage the
conductor cable.
When installing a screw on the terminal block, do not cut the cable by overtightening the
screw. On the other hand, an under tightened screw can cause faulty contact, which will
lead to a communication failure.
9381279029-02_IM.indb 89381279029-02_IM.indb 8 02/10/2019 13:24:0402/10/2019 13:24:04
En-9
7.4. Connection of wiring
7.4.1. Terminal Explanation and Cable Holes
• Only one cable can be passed through each cable hole. To pass multiple cables through
a single cable hole, use a (locally purchased) multi-conductor cable with more wires, and
bundle multiple cables into one.
• Maximum length of cable is 32 ft (10 m). (recommended value, Except "P1" and "TR1")
TH1
TH2
TH3
TH4
EV1
EV2
EX1
EX2
EX3
EX4
EX6
EX7
EX5
EX8
EX9
EX10
P1
D1
TR1
R1
P1: Power supply terminal
D1: Drain pump signal terminal
TR1: Transmission terminal
R1: Remote controller terminal
External interface terminal
Conduit hole positions (bottom of the Control unit)
H9 H10
H1 H2 H4
H3 H5
H6 H7 H8
Drain hole
Ø13/16 in
(Ø20 mm)
Hole diameter of H1 to H10:
Ø7/8 in (Ø22.2 mm)
Terminal No.
Terminal Name
Hole No.
Connection
Recommended
cable size (mm²)
Cable type
Specifications
P1 POWER SUPPLY H2 Power supply AWG14
(2.5)
Type245
IEC57 or
equivalent
208/230 V ~
60 Hz
187 to 253 V
2-cable + earth
(ground)
TR1 TRANSMISSION H3 Transmission
line
AWG22
(0.33)
LON-
WORKS®
compatible
cable
22 AWG LEVEL
4 (NEMA)
non-polar
2-core, twisted
pair solid core
diameter
0.026
in (0.65mm)
R1 REMOTE
CONTROLLER
H4 2-wire type
remote con-
troller
AWG22
to 16
(0.33 to
1.25)
Sheathed
PVC cable Non polar 2
core
3-wire type
remote con-
troller
AWG22
(0.33)
Sheathed
PVC cable Polar 3 core
D1 DRAIN PUMP H1 Drain pump AWG14
(2.5)
Type245
IEC57 or
equivalent
T1 THERMISTOR (GAS) H6 Thermistor
mounted to
the gas pipe
AWG22
(0.33)
Sheathed
PVC cable
Relay the
multi-con-
ductor cable,
and pass it
through the
designated
hole.
T2 THERMISTOR
(LIQUID)
Thermistor
mounted to
the liquid pipe
T3 THERMISTOR
(INLET AIR)
Thermistor
mounted to
the inlet
T4 THERMISTOR
(OUTLET AIR)
Thermistor
mounted to
the outlet
EV1 EEV1 1 - Red
2 - Brown
3 - Black
4 - Blue
5 - Yellow
6 - White
H9 Electronic
expansion
valve 1
AWG22
(0.33)
Sheathed
PVC cable
EV2 EEV2 H10 Electronic
expansion
valve 2
AWG22
(0.33)
Sheathed
PVC cable
Use the elec-
tronic expan-
sion valves
only when
two units are
connected
Terminal No.
Terminal Name
Hole No.
Connection
Recommended
cable size (mm²)
Cable type
Specifications
EX1 ON/OFF
SIGNAL
(OUTPUT)
External
output
/ Digital
H7 External
controller
AWG22
(0.33)
Sheathed
PVC cable
EX2 ERROR
SIGNAL
(OUTPUT)
External
output
/ Digital
EX3 FAN SIG-
NAL
External
output
/ Digital
EX4 DEFROST
SIGNAL
External
output
/ Digital
EX5 THER-
MOSTAT
ON/OFF
SIGNAL
External
output
/ Digital
EX6 ON/OFF
SIGNAL
(INPUT)
External
input
/ Digital
H8 External
controller
AWG22
(0.33)
Sheathed
PVC cable
ERROR
SIGNAL
• OFF (Open)
= Error
• ON (Short)
= Normal
EX7
(*1)
ERROR
SIGNAL
(INPUT)
External
input
/ Digital
The factory default
is shorted between
the terminals by the
cables.
EX8 COOL/
HEAT
SIGNAL
External
input
/ Digital
EX9 ANALOG
SIGNAL
External
input
/ Analog
EX
10
FLOAT SW
SIGNAL
External
input
/ Digital
H5 Float switch
mounted
to the heat
exchanger
AWG22
(0.33)
Sheathed
PVC cable
*1: The factory default is shorted between the terminals by the cables. If there is a mal-
function with an external device, using this external input is recommended in order to
protect the refrigerant system.
NOTES
Be sure to use conduits for all holes that pass through the connection wires to prevent
the entry of water, insects and small animals.
7.4.2. Unused holes
Attach the hole plug (accessories) to
the unused holes to prevent the entry of
insects and small animals.
Hole plug
(accessories)
7.4.3. Mount the wired remote controller to the inside of the control
unit
NOTES
When using the wired remote controller, if the temperature drops below 32°F (0°C),
the LCD display may become dim, the response may become slower, and the time ac-
curacy of the clock will be lost.
(1) Processing the remote controller cable
For 2-wire type remote controller (locally purchased)
3/8
(10)
1
(25)
29-1/2 (750)
Refer to the installation manual
of the remote controller.
To control unit To remote controller
[Unit: in (mm)]
For 3-wire type remote controller (attached with the remote controller)
3/8
(10)
1
(25)
29-1/2 (750)
To control unit To remote controller
Refer to the installation manual
of the remote controller.
[Unit: in (mm)]
9381279029-02_IM.indb 99381279029-02_IM.indb 9 02/10/2019 13:24:0402/10/2019 13:24:04
En-10
(2) Wiring the remote controller cable (door side)
See the wired remote controller installation manual for how to install the remote controller
and the wiring method. Further, as shown in the diagram below, pass and draw through
the remote controller cable from the case to the cable hole at the back of the case.
5-7/8 (150)
1-15/16 (50)
[Unit: in (mm)]
Remote controller cable Back side of the door
Fixed position of the
remote controller
Earth (ground)
cable
Cable tie mounts
(accessories)
Cable ties
(accessories)
Cable tie (accessories)
Bundle the remote
controller cable together
with the ground cable.
Screws M4 ×
L6 mm
(accessories)
Remote
controller
cable
Rear case of the
remote controller
(3) Wiring the remote controller cable (device side)
Y1 Y2 Y3Y1 Y2
Non-polar
(*1)
Red
White
Black
For 2-wire type For 3-wire type
Remote controller cable
Cable tie (accessories)
*1: If you connect the remote controller cable to the terminal Y3, 2-wire type remote
controller does not work.
(4) Set the DIP switch according to the type of remote controller used.
Factory setting: 2WIRE
DIP switch
(SW1)
7.5. External input and external output (Optional parts)
7.5.1. Digital external inputs
• Select either the apply voltage method or dry contact method for digital external inputs.
• Both types of terminals cannot be used simultaneously.
• Float witch signal is compatible with the dry contact method only.
Switch connectors as shown in the table below according to the method selected.
Terminal name
PCB connector (*: factory setting)
Apply voltage Dry contact
ON/OFF SIGNAL (INPUT) CNA01 CNA02*
ERROR SIGNAL (INPUT) CNA06 CNA07*
COOL / HEAT SIGNAL CNA03 CNA04*
FLOAT SW SIGNAL Incompatible CNA05*
CNA04
CNA02
CNA07
CNA01
CNB01
CNA03
CNA06
External input terminal
(Dry contact terminal)
External input terminal
(Apply voltage terminal)
External output terminal
Controller PCB
• Use an external input and output cable with appropriate external dimension, depending
on the number of cables to be installed.
• The wire connection should be separate from the power cable line.
Apply voltage terminal ([CNA01], [CNA03], [CNA06])
When a power supply must be provided at the input device you want to connect, use the
Apply voltage terminal ([CNA01], [CNA03], [CNA06]).
CNA01
(*b)
(*1)
(*a)
(*a)
(*a)
(*a)
CNA06
CNA03
Power supply
DC 12 to 24 V
Load re-
sistance
Load re-
sistance
Load re-
sistance
Load re-
sistance
Connected unit
Input 1Input 2Input 3
Control unit
Terminal
board
P.C.B.
*1
Make the power supply DC 12 to 24 V. Select a power supply capacity with an ample
surplus for the connected load.
Do not impress a voltage exceeding 24 V across pins 1 to 2, and 1 to 3.
*a The allowable current is DC 5 mA to 10 mA. (Recommended: DC 5 mA)
Provide a load resistance such that the current becomes DC 10 mA or less.
Select very low current use contacts (usable at DC 12 V, DC 1 mA or less).
*b The polarity is [+] for pin 1 and [-] for pin 2 and 3. Connect correctly.
9381279029-02_IM.indb 109381279029-02_IM.indb 10 02/10/2019 13:24:0502/10/2019 13:24:05
En-11
When connected to Apply voltage terminals of multiple DX-kits with a connected unit,
be sure to make a branch outside the DX-kit using a pull box, etc. as shown on below
example.
CNA01
CNA01
CNA01
Power supply
DC 12 to 24 V
Load re-
sistance
Load re-
sistance
Connected unit
Input
device 2
Control unitControl unit Control unit
Input
device 1
Terminal
board
P.C.B.
Dry contact terminal ([CNA02], [CNA04], [CNA07])
When a power supply is unnecessary at the input device you want to connect, use the Dry
contact terminal ([CNA02], [CNA04], [CNA07]).
*d
*d
*d
*c
Ch 4
*c
Ch 3
*c
Ch 1
*c
Ch 2
CNA02
CNA04
CNA07
Control unit
Terminal
board
P.C.B.
GND
Connected unit
*c Select very low current use contacts (usable at DC 12 V, DC 1 mA or less).
*d The wiring is different from Apply voltage terminals. Be suf ciently careful when wiring.
When connected to Dry contact terminals of multiple indoor units with a connected unit,
insulate each indoor unit with relay, etc. as shown on below example.
K1
K2
K3
K4
K5
K6
Power supply for relay
Control unit
Control unit
Control unit
Input device 2
Input device 1
K1 - K6: Relay
(Device for DC Current)
P.C . B
P.C . B
P.C . B
NOTES
When connected to multiple indoor units directly, it will cause breakdown.
Operation behavior
Input signal type
The input signal type can be selected.
It is switched by DIP switch on the indoor unit PCB.
Pulse
The width of pulse must
be longer than 200 ms.
Edge
(1) ON/OFF SIGNAL (INPUT)
[For the “Edge” input method, function setting “60” is set to “00”]
Terminal block Input signal Command
ON/OFF SIGNAL
(INPUT)
Pin 1 to Pin 3
OFF ON Operation
ON OFF Operation stopped
[For the “Edge” input method, function setting “60” is set to “01”]
Terminal block Input signal Command
ON/OFF SIGNAL
(INPUT)
Pin 1 to Pin 3
OFF ON Cooling operation
ON OFF Operation stopped
[For the “Pulse” input method]
Terminal block Input signal Command
ON/OFF SIGNAL
(INPUT)
Pin 1 to Pin 2 OFF ON Operation
Pin 1 to Pin 3 OFF ON Stop
* The last command has priority.
* The indoor units within the same remote controller group operates in the same mode.
(2) ERROR SIGNAL (INPUT)
If an error signal is input, perform protection operation (Thermostat OFF mode).
Make sure to install so that the input signals during normal operation is always “ON”.
Terminal block Input signal Command
ERROR SIGNAL
(INPUT)
Pin 1 to Pin 2
ON Normal
OFF Error
(3) COOL/HEAT SIGNAL
Switch the operation mode (heating/cooling).
[“Edge” input method, function setting “60” is set to “00”]
Terminal block Input signal Command
COOL/HEAT
SIGNAL
Pin 1 to Pin 2
OFF ON Heat
ON OFF Cool
[“Edge” input method, function setting “60” is set to “01”]
Terminal block Input signal Command
COOL/HEAT
SIGNAL
Pin 1 to Pin 2
OFF ON Heating operation
ON OFF Operation stopped
NOTES
• In heat recovery system, HEAT/COOL switching during operation is disabled unless
the RB unit and DX-kit are connected in 1-to-1.
• If switching the operation mode directly from cooling to heating to cooling, set the
priority mode to “indoor unit priority” (*1), and set the DX-kit to “Administrative indoor
unit (or Master indoor unit) (*2)”. Making this setting when the DX-kit and the VRF for
another indoor unit are connected to the same refrigerant system will make the DX-kit
prioritize the operation mode, so be careful.
*1: For the setting methods, refer to the installation manual for the outdoor unit in
V-II and J-II systems, and refer to the installation manual for the RB unit in VR-II
system.
*2: For the settings method, see the wired remote controller installation manual and
this installation manual.
(4) FLOAT SW SIGNAL
Check the drain status.
If the “ON” status continues for 3 minutes or more, decide a drainage error, and perform
a protection stop. (Thermostat OFF and FAN OFF mode) Further, turn OFF and ON the
power again to restore.
[“Edge” input only]
Connector Input signal Command
FLOAT SW SIG-
NAL
Pin 1 to Pin 3
OFF ON
Protection opera-
tion
ON OFF Normal
7.5.2. Analog external inputs
Changing the voltage of the signals entered to “analog external inputs” enables you to set
either the operation temperature or the required operation performance.
If using this function, make the following DIP switch settings.
i) Set the “Analog external inputs ON/OFF” setting to “ON”.
ii) Set the control item (either the operation temperature or required operation perfor-
mance).
Connected unit
Connected
device
Control unit
(DX-kit)
Analog signal
9381279029-02_IM.indb 119381279029-02_IM.indb 11 02/10/2019 13:24:0502/10/2019 13:24:05
En-12
7.5.3. External output
No. Terminal block
Type-i Type-ii
Status
DX-kit internal
relay status
DX-kit output
level
1 ON/OFF SIGNAL ON (Open) OFF Stop
OFF (Short) ON (DC 12 V) Operation
2 ERROR SIGNAL ON (Open) OFF Normal
OFF (Short) ON (DC 12 V) Error
3 FAN SIGNAL ON (Open) OFF FAN off
OFF (Short) ON (DC 12 V) FAN on
4 DEFROST SIGNAL ON (Open) OFF Normal
OFF (Short) ON (DC 12 V) Defrosting
5 THERMOSTAT
ON/OFF SIGNAL
ON (Open) OFF Thermostat Off
OFF (Short) ON (DC 12 V) Thermostat On
6 DRAIN PUMP
SIGNAL (*1)
OFF Drain pump Off
ON (AC 230 V) Drain pump On
Select either of the following two power supply methods. (Factory setting is Type-i)
Type-i
• Using a power supply from other than the DX-kit (Connected unit, etc.)
• Usable tolerance voltages and currents: AC 208/230 V / 1 A max or DC 30
V max / 1 A Max
Type-ii
• Using a power supply from the DX-kit control unit
• Output voltage: Hi DC 12 V ± 2 V, Lo 0 V / 50 mA max
• Use an external input and output cable with appropriate external dimension, depending
on the number of cables to be installed.
Type-i:
Using a power supply from other than the DX-kit (Connected unit, etc.)
1
2
3
4
5
6
Power supply
Terminal
Relay PC
board
Control unit (DX-kit)
Connected unit
Connected
device 1
Connected
device 2
Connected
device 3
Connected
device 4
Connected
device 5
Drain pump
PC board
Power supply
for drain pump
AC 208/230 V / 1A max
DC 30 V max / 1A max
When using a drain pump, connect relay that is
compatible with AC power supply. (locally purchased)
Precautions for Type-i
If connecting a dielectric load such as a relay coil, etc., to the connected device, make
sure to add a surge protector circuit to the load side as shown in the diagram.
32
33
1
Power supply
Connected device
Relay
Dielectric load
Surge protector circuit
Control unit (DX-kit)
Terminal
Relay PC
board
PC board
Type-ii:
Using a power supply from the DX-kit control unit
32
33
34
35
40
41
38
39
36
37
5
1
4
3
2
6
CNB01
Terminal
12 V DC line
Control unit (DX-kit)
Connected unit
Connected
device 1
Connected
device 2
Connected
device 3
Connected
device 4
Connected
device 5
Drain pump
PC board
Power supply
for drain pump
When using a drain pump, connect relay that is
compatible with AC power supply. (locally purchased)
• If Type-ii is selected, change the wiring as shown in the diagram. (All cables used are
enclosed.)
(a1)
(b) (c) (d) (e)
(a2)
(a3)
(a4)
(a5)
(a6)
41403938373635343332
(a)
CNB01
CNB01
CN800
CN801 CN802
About the cable name and
cable color
(a) Connection cable 1:
(a1) Brown, (a2) Red
(a3) Orange, (a4) Yellow
(a5) White, (a6) Blue
(b) Connection cable 2:
Brown
(c) Connection cable 3:
Brown
(d) Connection cable 4:
Brown
(e) Connection cable 5:
Brown
Cable clamps
If connecting the connection cables (accessories) to a terminal, make sure to
match the number of the label affixed to the cable with the terminal number.
9381279029-02_IM.indb 129381279029-02_IM.indb 12 02/10/2019 13:24:0502/10/2019 13:24:05
En-13
8. FIELD SETTING
SET*-SW1
SET*-SW2
SET*-SW3
SET*-SW4
IU AD ×10
IU AD ×1
REF AD ×1
REF AD ×10
RC AD ×1
SET2
SET3
SET4
SET1
DIP switch
[LED1 indicator]
ON: Normal operation
Flashing: Error
DIP switch
Rotary switch
LED1
DIP switch
CAUTION
Be sure to turn OFF the power before performing the field setting.
8.1. Setting the address
8.1.1. Setting the indoor unit address and refrigerant circuit
address controlled by the DX-kit
(1) Setting automatic address
:
Set the rotary switch IU_AD,REF_AD to 0.
(For the advanced function settings, see the outdoor
unit installation manual.)
(2) Setting manual address: Set the rotary switch IU_AD,REF_AD to the specified
value.
Manual address setting method
• If the receiver unit is attached, the indoor unit address and the refrigerant circuit address
can also be set up through the wireless remote controller.
CAUTION
Use an insulated screwdriver to set the DIP switches.
Setting
Setting
range
Type of switch
Indoor unit address controlled by the DX-
kit
• Rotary switch [IU AD × 1]
(Factory setting “0”)
• Rotary switch [IU AD × 10]
(Factory setting “0”)
When connecting multiple indoor units to 1
refrigerant system, set the address at IU AD SW
as shown in the Table A.
0 to 63
Setting example 2
IU AD × 10 IU AD × 1
Refrigerant circuit address
• Rotary switch [REF AD × 1]
(Factory setting “0”)
• Rotary switch [REF AD × 10]
(Factory setting “0”)
In the case of multiple refrigerant systems, set
REF AD SW as shown in the Table A for each
refrigerant system.
Set to the same refrigerant circuit address as the
outdoor unit.
0 to 99
Setting example 63
REF AD × 10 REF AD × 1
• If working in an environ-
ment where the wireless
remote controller can be
used, the addresses can
also be set using the
remote controller.
• If setting the addresses
using the wireless
remote controller, set
the indoor unit address
and refrigerant circuit
address to “00”.
(For information on set-
ting using the wireless
remote controller.)
* Do not set the indoor
unit address (IU AD
SW) at 64 to 99.
It may result in failure.
Table A
Address
Rotary switch
setting
Address
Rotary switch
setting
Refrigerant
circuit
REF AD SW
Indoor unit
IU AD SW
× 10 × 1 × 10 × 1
000000
101101
202202
303303
404404
505505
⁞⁞⁞⁞⁞
10 1 0 10 1 0
11 1 1 11 1 1
⁞⁞⁞⁞⁞
99 9 9 63 6 3
8.1.2. Remote controller address
• Set this address if connecting a Fujitsu general remote controller.
• If using analog inputs, Fujitsu general remote controller operation will be disabled.
If using analog inputs, DX-kit cannot form the remote controller group.
RC AD SW
0
RC AD SW
1
RC AD SW
0
RC AD SW
1
DX-kit DX-kit
Remote
controller
DX-kit cannot form the same remote controller
group as the indoor unit of other type.
DX-kit Indoor unit
i) 3-wire type
• Rotary switch (RC AD SW)...Factory setting “0”
• When connecting multiple indoor units to 1 standard wired remote controller, set the ad-
dress at RC AD SW in sequence from 0.
Setting Setting range Type of switch
Remote controller
address
0 to 15
Setting
example
0
RC AD
RC AD SW
0123456789ABCDEF
Address
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
ii) 2-wire type
• Rotary switch (RC AD SW)...Factory setting “0”
• Since the remote controller address settings are automatically configured, you do not
need to configure them.
• If configuring manually, it is necessary to configure both the indoor unit and the remote
controller.
• For details, please refer to the remote controller manual.
9381279029-02_IM.indb 139381279029-02_IM.indb 13 02/10/2019 13:24:0602/10/2019 13:24:06
En-14
8.2. Dip switch setting
8.2.1. Capacity settings of indoor units to be controlled
The capacity of indoor units to be controlled is set.
Indoor unit capacity
[kBTU/h (kW)]
Dip switch setting
SET1-1 SET1-2 SET1-3 SET1-4 SET2-1
18 (5.3)
(factory setting)
ON OFF ON OFF OFF
24 (7.0) OFF ON ON OFF OFF
30 (8.8) OFF OFF OFF ON OFF
36 (10.6) ON OFF OFF ON OFF
48 (14.1) OFF ON OFF ON OFF
60 (17.6) OFF OFF ON ON OFF
72 (21.2) ON OFF ON ON OFF
96 (28.1) ON ON ON ON OFF
144 (42.2) ON OFF OFF ON ON
168 (49.2) OFF ON OFF ON ON
Not described above Settings prohibited
8.2.2. Setting digital input signal methods
Select either edge method or
pulse method as the external
inputs signal method.
DIP switch SET2-2 Digital input signals format
OFF (factory setting) Edge
ON Pulse
Make sure that SET2-3 and SET2-4 are always OFF.
8.2.3. Analog external inputs method
• You can select the item to be controlled using analog external inputs from the external
controller (either “Operation temperature” or “Required operation performance”).
• Make the DIP switch SET3-1 settings before making the SET3-2 settings.
• Make sure to set a connection status that uses the external controller.
• If SET3-1 is ON, VRF device controls will be disabled.
(i) Analog external inputs
ON/OFF
DIP switch SET3-1 Analog external inputs
ON/OFF
OFF (factory setting) OFF
ON ON
(ii) Control items
The items to be controlled
are selected according to the
device status that uses the
external controller.
DIP switch SET3-2 Control conditions
OFF (factory setting) Operation temperature
ON Required operation perfor-
mance
8.2.4. AC (air conditioning.) control settings
Select the AC control format
from either “outlet temperature
control” or “inlet temperature
control”.
DIP switch SET3-3 Temperature control position
OFF (factory setting) Outlet temperature control
ON Inlet temperature control
Make sure that SET3-4 is always OFF.
8.2.5. RB unit bypass circuit feasibility
• If connecting the RB unit and a
general indoor unit 1-to-1 in the
heat recovery system unit, config-
ure a bypass circuit in the RB unit
when the heat thermostat is OFF.
DIP switch SET4-3
OFF (factory setting) No bypass
ON With bypass
• Prevents hot air from outlet when the heat thermostat is OFF.
• If the indoor unit is 40kW or 50kW type, the RB unit cannot be connected.
8.2.6. Administrative indoor unit setting
• You can set the DX-kit as the
“administrative indoor unit” from
among multiple indoor units
(including the DX-kit) connected
using the same refrigerant system
(or RB unit).
DIP switch SET4-4 Administrative indoor
unit settings
OFF (factory setting) OFF
ON ON
• Only one administrative indoor unit can be set using the same refrigerant system (or RB
unit). If forming the remote controller group, set this DIP switch "OFF".
• When connecting the wired remote controller to the DX-kit, set this switch to OFF. (Set
the “Administrative indoor unit setting” with the wired remote controller.)
Make sure to set SET4-1 and SET4-2 to always OFF.
Precautions if using
the DX-kit as the
administrative indoor
unit
If the “Administrative indoor unit setting” is “ON” for another
indoor unit connected to the same refrigerant system (or RB
unit), make sure to turn ”OFF” that setting. For details, see
the wired remote controller installation manual.
8.2.7. Remote controller selections
The cable type of wired remote
controller has been selected.
DIP switch SW1 Wired remote controller
cable type
2WIRE (factory setting) 2 wire type
3WIRE 3 wire type
8.3. Function setting
• FUNCTION SETTING can be performed with the wired or wireless remote controller.
(The remote controller is optional equipment)
• Refer to the wired or wireless remote controller manual for detailed setting information.
(Set IU AD, REF AD SW to 0)
• Refer to “8.1. Setting the address” for indoor unit address and refrigerant circuit address
settings.
Turn the power of the indoor unit ON before starting the setting.
* Turning on the power to the indoor units initializes EEV, so make sure the piping air
tight test and vacuuming have been conducted before turning on the power.
* Also check again to make sure no wiring mistakes were made before turning on the
power.
Function details
Function
Function
number
Setting
number
Default
Details
Filter indicator
interval
11
00 Standard
Adjust the filter cleaning interval
notification. If the notification is too
early, change to setting 01. If the
notification is too late, change to
setting 02.
01 Longer
02 Shorter
Filter indicator
action
13
00 Enable
Enable or disable the filter indicator.
Setting 02 is for use with a central
remote controller.
01 Disable
02
Display only
on central
remote con-
troller
Auto restart 40
00 Enable
Enable or disable automatic system
restart after a power outage.
01 Disable
Cool Air Pre-
vention
43
00 Super low Restrain the cold airflow with mak-
ing the airflow lower when starting
heating operation.
If using Outlet temperature control
(DIP switch SET3-3: OFF), set this
function"01".
01
Follow the
setting on
the remote
controller
Error report
target
47
00 All
Change the target for reporting
errors. Errors can either be reported
in all locations, or only on the
central remote controller.
01
Display only
on central
remote
controller
Switching
functions for
external inputs
and external
outputs termi-
nals
60
00 Mode 0
The connection terminal functions
can be changed depending on the
type of external device. For details
of the connection terminal func-
tions, see the Design & Technical
Manual.
01 Mode 1
Selecting stop
operation dur-
ing an external
error
64
00 Mode 0
Thermostat off
01 Mode 1 Thermostat OFF + fan stop
02 Mode 2
Thermostat OFF + fan stop +
outdoor unit stop
9381279029-02_IM.indb 149381279029-02_IM.indb 14 02/10/2019 13:24:0602/10/2019 13:24:06
En-15
9. TEST RUN
The test run function will force the outdoor unit to operate. When performing the test run,
confirm that the entire system including the external devices operates normally. (If only the
outdoor unit operates, it may cause damage to the entire refrigerant system.)
9.1. Test run using Outdoor unit (PCB)
Refer to the installation manual for the outdoor unit if the PCB for the outdoor unit is to be
used for the test run.
9.2. Test run using remote controller
Refer to the installation manual for the remote controller to perform the test run using the
remote controller. (If using analog inputs, Fujitsu general remote controller operation will
be disabled.)
10. CHECK LIST (Example)
Pay special attention to the check items below when installing the entire system. After
installation is complete, be sure to check the following check items again.
Check items If not performed correctly
Check
box
Are the external devices and DX-Kit
operating as expected?
No operation, heat or burn damage
Has the indoor unit been installed cor-
rectly?
Vibration, noise, indoor unit may drop
Has there been a check for gas leaks
(refrigerant pipes)?
No cooling, No heating
Has heat insulation work been com-
pleted?
Water leakage
Does water drain easily from the indoor
units?
Water leakage
Is the voltage of the power source the
same as that indicated on the label on
the indoor unit?
No operation, heat or burn damage
Are the wires and pipes all connected
completely?
No operation, heat or burn damage
Is the indoor unit earthed (grounded)? Short circuit
Is the connection cable the speci ed
thickness?
No operation, heat or burn damage
Are the inlets and outlets free of any
obstacles?
No cooling, No heating
Does start and stop air conditioner op-
eration by remote controller or external
device?
No operation
After installation is completed, has the
proper operation and handling been
explained to the user?
11. ERROR CODES
• When an error occurs, the LED on the PC board (LED name: LED1) flashes.
• “Error code” can be viewed by connecting the optional wired remote controller, group
remote controller, and IR receiver unit, etc.
If you use a wired type remote controller (Optional parts), error codes will appear on the
remote controller display. If you use a wireless remote controller (IR receiver unit of op-
tional parts), the lamp on the photodetector unit will output error codes by way of blinking
patterns. See the lamp blinking patterns and error codes in the table below.
Error indications
Wired remote
controller
error code
Error contents
OPERATION
lamp (green)
TIMER lamp
(orange)
FILTER lamp
(red)
(1) (2)
Remote controller communi-
cation error
(1) (4)
Network communication error
(1) (6)
Peripheral unit communica-
tion error
(2) (6)
Indoor unit address setting
error
(2) (9)
Connection unit number error
in wired remote controller
system
(3) (1)
Indoor unit power supply
abnormal
(3) (2)
Indoor unit main PCB error
(3) (10)
Indoor unit communication
circuit (wired remote control-
ler) error
(4) (2)
Indoor unit heat ex. temp.
thermistor error
(4) (10)
Indoor unit air temp. thermis-
tor error
(5) (2)
Indoor unit coil (expansion
valve) error
(5) (3)
Indoor unit water drain
abnormal
(9) (15)
Outdoor unit miscellaneous
error
(13) (1)
RB unit error
(13) (6)
DX-kit error
Display mode
: 0.5 s ON / 0.5 s OFF
: 0.1 s ON / 0.1 s OFF
( ) : Number of flashing
Wired Remote Controller Display
Error code
Error icon
Touch the [Next Page] (or [previous page])
to switch to other indoor unit information.
Touch the [Status]. Touch the [Error Information].
2-digit numbers are corresponding to
the error code in the preceding table.
For more information, refer to the installation manual of the remote controller.
UTY-RNKU (3-wire type)
UTY-RNRU (2-wire type)
For details on marking the ERROR CODES, refer to the Manual of “Wired Remote Controller”.
9381279029-02_IM.indb 159381279029-02_IM.indb 15 02/10/2019 13:24:0602/10/2019 13:24:06
En-16
12. OPERATIONS
12.1. Analog external inputs
CAUTION
Use an insulated screwdriver to set the adjustment dial.
Do not apply voltage greater than 10 V.
The operation temperature and required operation performance are set by changing the
voltage of the signals entered to “analog external inputs”. Compensating the analog circuit
tolerance before using this function is recommended.
(1) Initial settings for using the analog external inputs circuit.
• Set the DIP switch SET3-1 to “ON”.
• Set the DIP switch SET3-2 to “OFF”.
(2) Compensate the tolerance of the circuit that measures the voltage of the analog input
signals.
Analog inputs
adjustment dial
Connected unit
Power supply
DC 5 V
Terminal block
PC board
VR700
Control unit (DX-kit)
VR700
Compensation method
i) Connect the power supply adjusted to output DC 5 V to the designated terminal.
ii) Turn ON the power supply.
iii) Use the adjustment dial to compensate so that the temperature display for the wired
remote controller indicates 68°F (20°C).
Setting the operation temperature using analog external inputs
Connected unit
Connected
device
Control unit
(DX-kit)
Analog signal
The operation temperature is set by changing the voltage of the input signals.
(If using this function, set the DIP switch SET3-2 to “OFF”.)
Formula:
Operation temperature T (°F) = 5.0 × AIN + 43.0
AIN = Input voltage (1.0 to 9.0 V)
See the following diagram for the advanced input conditions.
a) Using the inlet to control the temperature
b) Using the outlet to control the temperature
88°F
(30°C)
78°F
(25°C)
56°F
(14°C)
88°F
(30°C)
84°F
(28°C)
62°F
(17°C)
64°F
(18°C)
48°F
(10°C)
4.2 V
2.6 V
3.8 V 8.2 V
7.0 V
9.0 V 1.0 V 9.0 V
Cooling
Cooling
Input voltage
Operation
temperature
Operation
temperature
Input voltage
Input voltage
Input voltage
Heating
Heating
(3) Setting required operation performance using analog external inputs
• The operation capacity can be set by changing the voltage of the input signals.
* Refrigerant cycle protection is prioritized, so operation may not be as required.
• If using this function, set the DIP switch SET3-2 to “ON”.
Formula:
Required operation performance C (%) = 12.5 × AIN - 11.25
AIN = Input voltage (1.3 to 8.9 V)
If AIN < 1.3 V, C = 0% fixed
If AIN > 8.9 V, C = 100% fixed
Input voltage
Required operation
performance
1.3 V 8.9 V
100%
5%
9381279029-02_IM.indb 169381279029-02_IM.indb 16 02/10/2019 13:24:0702/10/2019 13:24:07
Fr-1
1. CONSIGNES DE SÉCURITÉ
• Avant d’installer cet appareil, veuillez lire attentivement ce manuel.
• Les avertissements et précautions indiqués dans ce manuel contiennent des informa-
tions importantes pour votre sécurité. Assurez-vous de les respecter.
• Remettez ce manuel au client. Demandez au client de les conserver soigneusement
pour toute utilisation future, par exemple pour déplacer ou réparer l’appareil.
• Pour l'installation de l'unité de traitement de l'air (échangeur de chaleur), référez-vous au
manuel d'installation de l'unité de traitement de l'air.
AVERTISSEMENT
Ce symbole signale toute procédure qui, si elle est
exécutée de manière incorrecte, peut provoquer de
graves blessures, voire la mort de l’utilisateur.
Demandez à votre revendeur ou à un installateur professionnel d’installer le kit DX
intérieur conformément aux instructions du présent manuel d’installation. Une unité
installée de façon incorrecte peut être la cause d’accidents graves, tels que fuites d’eau,
choc électrique ou incendie. Si le kit DX est installé sans tenir compte des instructions
données dans le manuel d’installation, la garantie du fabricant devient nulle.
Ne mettez pas l’appareil sous tension tant que l’installation n’est pas complètement
terminée. Vous risqueriez de provoquer un accident grave, tel qu’un choc électrique ou
un incendie.
En cas de fuite de réfrigérant pendant l’installation, ventilez la zone. Si le réfrigérant
entre en contact avec une flamme, un gaz toxique est produit.
Le travail d’installation doit être effectué conformément aux normes de câblage natio-
nales seulement par du personnel autorisé.
Sauf en cas d’URGENCE, ne coupez jamais le conducteur principal ni le disjoncteur
des kits DX pendant le fonctionnement. Cela provoquerait une panne du compresseur
ainsi qu’une fuite d’eau. En premier lieu, arrêtez le kit DX à l’aide de la télécommande,
du convertisseur ou d’un dispositif d’entrée extérieur, puis coupez le disjoncteur.
Assurez-vous de passer par la télécommande, le convertisseur ou un dispositif d’entrée
extérieur.
Lors de la conception du disjoncteur, placez-le à un endroit où les utilisateurs ne
peuvent pas le démarrer ou l’arrêter au cours de leur travail quotidien.
ATTENTION
Ce marquage indique des procédures qui, si elles ne sont
pas effectuées correctement, peuvent entraîner des bles-
sures corporelles ou des dommages matériels.
Avant d’utiliser ou d’installer le kit DX, lisez attentivement toutes les informations rela-
tives à la sécurité.
N’essayez pas d’installer vous-même le kit DX ou une partie de celui-ci.
Cet appareil doit être installé par un personnel qualifié titulaire d’un certificat d’aptitude
en manipulation des fluides frigorigènes. Référez-vous à la réglementation et à la législa-
tion en vigueur sur l’emplacement d’installation.
L’
installation doit être effectuée conformément à la réglementation en vigueur
sur
l’emplacement d’installation et à la notice d’installation du fabricant.
Cet appareil fait partie d’un ensemble formant le kit DX. Il ne doit pas être installé isolé-
ment ou avec un équipement non autorisé par le fabricant.
Utilisez toujours une ligne d’alimentation séparée, protégée par un disjoncteur fonction-
nant sur tous les fils, en respectant une distance de 1/8 po (3 mm) entre les contacts
pour cet appareil.
L’appareil doit être correctement relié à la masse et la ligne d’alimentation doit être
équipée d’un disjoncteur différentiel afin de protéger les personnes.
Les appareils ne sont pas antidéflagrants. Ils ne doivent donc pas être installés dans une
atmosphère explosive.
Ne touchez jamais des composants électriques immédiatement après la coupure de
l’alimentation. Un choc électrique pourrait se produire. Après avoir coupé le courant,
patientez 5 minutes avant de toucher des composants électriques.
Cet appareil ne contient aucune pièce dont l’entretien est à charge de l’utilisateur. Pour
les réparations, adressez-vous toujours à un technicien de service agréé.
En cas de déménagement, faites appel à un technicien de service agréé pour débran-
cher et installer l’appareil.
2. INFORMATIONS SUR LE PRODUIT
2.1. Précautions d’utilisation du réfrigérant R410A
AVERTISSEMENT
N’introduisez aucune substance autre que le fluide frigorigène prescrit dans le circuit de
réfrigération. Toute pénétration d’air dans le circuit de réfrigération provoque une éléva-
tion excessive de la pression et est susceptible de causer la rupture des conduites.
En cas de fuite de réfrigérant, assurez-vous que la valeur limite de concentration n’est
pas dépassée. Si une fuite de réfrigérant dépasse la valeur limite de concentration, un
manque d’oxygène peut alors survenir.
Ne touchez pas le réfrigérant qui s’échappe des raccordements du circuit de réfrigé-
ration ou d’autres zones. Tout contact direct avec le réfrigérant peut provoquer des
gelures.
En cas de fuite de réfrigérant pendant l’utilisation de l’appareil, quittez immédiatement
les lieux et ventilez soigneusement la zone. Si le réfrigérant entre en contact avec une
flamme, un gaz toxique est produit.
2.2. Outil spécial pour R410A
AVERTISSEMENT
Pour l’installation d’une unité qui contient du réfrigérant R410A, utilisez les outils et les
matériaux de tuyauterie qui ont été spécifiquement conçus pour l’usage de R410A. La
pression du R410A étant environ 1,6 fois supérieure à celle du R22, le fait de ne pas
utiliser la tuyauterie spéciale ou de réaliser une installation incorrecte peut provoquer la
rupture du circuit ou des blessures.
Il peut en outre se produire des accidents graves, tels que fuites d’eau, choc électrique
ou incendie.
Nom de
l’outil
Modifications
Manomètre
La pression dans le système de réfrigération est extrêmement élevée et
ne peut pas être mesurée avec un manomètre classique. Pour empê-
cher le mélange accidentel d’autres fluides frigorigènes, le diamètre de
chaque orifice a été modifié. Il est recommandé d’utiliser un manomètre
doté d’une plage d’affichage haute pression de 500 microns à 768 psi
(-0,1 à 5,3 MPa), et d’une plage d’affichage basse pression de 500
microns à 551 psi (-0,1 à 3,8 MPa).
Flexible de
remplissage
Pour augmenter la résistance à la pression, le matériau du flexible et la
taille de la base ont été modifiés.
Pompe à
vide
Il est possible d’utiliser une pompe à vide conventionnelle moyennant
l’installation d’un adaptateur.
Veillez à ce que l’huile de la pompe ne reflue pas dans le système. La
pompe doit être capable d’aspirer à 500 microns (-100,7 kPa).
Détecteur de
fuite de gaz
Détecteur de fuite de gaz spécial pour réfrigérant R410A.
2.3. Accessoires
AVERTISSEMENT
Pour l’installation, veillez à utiliser les pièces fournies par le fabricant ou autres pièces
recommandées. L’utilisation de pièces non recommandées peut être la cause d’acci-
dents graves, tels que chute de l’appareil, fuites d’eau, choc électrique ou incendie.
Les pièces d’installation suivantes sont fournies. Utilisez-les en respectant les indica-
tions.
Conservez le manuel d’installation dans un endroit sûr et ne jetez aucun autre acces-
soire, jusqu’à ce que l’installation soit terminée.
MANUEL D’INSTALLATION
N° DE PIÈCE 9381279029-02
Kit DX à système VRF
Contenu
1. CONSIGNES DE SÉCURITÉ ........................................................................................1
2. INFORMATIONS SUR LE PRODUIT ............................................................................1
2.1. Précautions d’utilisation du réfrigérant R410A ....................................................1
2.2. Outil spécial pour R410A ....................................................................................1
2.3. Accessoires ........................................................................................................1
2.4. Pièces en option .................................................................................................2
2.5. Informations concernant l’unité de longueur .......................................................2
3. SÉLECTION DU PRODUIT ...........................................................................................3
3.1. Réglage du produit .............................................................................................3
3.2. Conception du système ......................................................................................3
4. TRAVAUX D’INSTALLATION .......................................................................................3
4.1. Choix du lieu d’installation ..................................................................................3
4.2. Dimensions de l’installation ................................................................................4
4.3. Installation de l’appareil ......................................................................................4
5. INSTALLATION DE LA TUYAUTERIE .........................................................................5
5.1. Sélection du matériau des tuyaux ......................................................................5
5.2. Exigence relative aux tuyaux ..............................................................................5
5.3. Cintrage des tuyaux ............................................................................................6
5.4. Raccordement des tuyaux ..................................................................................6
5.5. Installation de l’isolation thermique .....................................................................6
6. INSTALLATION DES SONDES TEMPÉRATURES ......................................................6
7. CÂBLAGE ÉLECTRIQUE .............................................................................................7
7.1. Spéci cations électriques ...................................................................................7
7.2. Méthode de câblage ...........................................................................................7
7.3. Câblage de l’appareil ..........................................................................................8
7.4. Raccordement du câblage ..................................................................................9
7.5. Entrée externe et sortie externe (pièces en option) ..........................................10
8. RÉGLAGE SUR SITE .................................................................................................13
8.1. Réglage de l’adresse ........................................................................................13
8.2. Réglage du commutateur Dip ...........................................................................14
8.3. Réglage des fonctions ......................................................................................14
9. ESSAI DE FONCTIONNEMENT .................................................................................15
9.1.
Test de fonctionnement à l’aide de l’unité extérieure (carte à circuits imprimés) ....
15
9.2. Test de fonctionnement en utilisant la télécommande ......................................15
10. LISTE DE CONTRÔLE (Exemple) ...........................................................................15
11. CODES D’ERREUR ..................................................................................................15
12. OPÉRATIONS ...........................................................................................................16
12.1. Entrées externes analogiques ........................................................................16
9381279029-02_IM.indb 19381279029-02_IM.indb 1 02/10/2019 13:24:0702/10/2019 13:24:07
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Fujitsu UTY-VDGU Guide d'installation

Catégorie
Climatiseurs split-system
Taper
Guide d'installation

dans d''autres langues