Greenlee GT-16 Manuel utilisateur

Catégorie
Compteurs d'électricité
Taper
Manuel utilisateur

Ce manuel convient également à

1
INSTRUCTION MANUAL MANUALE DI ISTRUZIONIMANUEL D’INSTRUCTIONS
KEEP THIS MANUAL
(continued on back side, column 1)
CONSERVER CE MANUEL
(suite au verso, colonne 2)
CONSERVARE QUESTO MANUALE
(continua sul lato posteriore, colonna 3)
GT-16 Voltage Detector
52058081 © 2011 Greenlee Textron Inc. 1/11
Description
The Greenlee GT-16 Voltage Detector is intended to check for the
presence of AC voltage, signaling the user with an intermittent tone
and a flashing LED. The LED flashes periodically to confirm battery
condition.
Safety
Safety is essential in the use and maintenance of Greenlee tools and
equipment. This instruction manual and any markings on the tool
provide information for avoiding hazards and unsafe practices related to
the use of this tool. Observe all of the safety information provided.
Purpose of This Manual
This instruction manual is intended to familiarize all personnel with
the safe operation and maintenance procedures for the Greenlee GT-16
Voltage Detector.
Keep this manual available to all personnel. Replacement manuals are
available upon request at no charge at www.greenlee.com.
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
All specifications are nominal and may change as design improvements
occur. Greenlee Textron Inc. shall not be liable for damages resulting from
misapplication or misuse of its products.
® Registered: The color green for electrical test instruments is a registered
trademark of Greenlee Textron Inc.
Romex is a registered trademark of General Cable Industries, Incorporated.
Symbols on the Unit
Warning—Read the instruction manual
Risk of electric shock
Double insulation
Important Safety Information
Read and understand this material before
operating or servicing this equipment. Failure to
understand how to safely operate this tool could
result in an accident causing serious injury or
death.
Electric shock hazard:
Contact with live circuits could result in severe
injury or death.
Electric shock hazard:
• Do not assume that no voltage indication means that the
circuit is de-energized.
• Follow the 3-point safety method as described in the
“Operation” section (steps 2, 3, and 4).
• Do not use the unit if it is wet or damaged.
• Do not apply more than the rated voltage between the tip and
earth ground.
• Do not operate with the case open.
• This tester will not detect voltage through metal conduit, on
armored or shielded cable, on sheathed nonmetallic cable that is
saturated with water, or at a distance such as through walls.
• Using this unit near equipment that generates electromagnetic
interference can result in unstable or inaccurate readings.
Failure to observe these warnings could result in severe injury or
death.
Electric shock hazard:
• Do not attempt to repair this unit. It contains no user-serviceable
parts.
• Do not expose the unit to extremes in temperature or high
humidity. Refer to “Specifications.”
Failure to observe these precautions may result in injury and can
damage the unit.
Rilevatore di tensione GT-16
52058081 © 2011 Greenlee Textron Inc. 1/11
Descrizione
Il rilevatore di tensione Greenlee GT-16 è inteso per controllare la
presenza di tensione c.a., segnalando l’utente con un segnale acustico
intermittente ed una spia LED lampeggiante. La spia LED lampeggia
periodicamente per confermare il livello di carico delle pile.
Sicurezza
La sicurezza è essenziale per l’uso e la manutenzione degli attrezzi e
delle apparecchiature Greenlee. Questo manuale delle istruzioni e tutte
le indicazioni sull’attrezzo forniscono informazioni relative a questo
attrezzo necessarie per evitare pericoli e modalità d’utilizzo non sicure.
Attenersi sempre a tutte le istruzioni per la sicurezza fornite.
Scopo di questo manuale
Questo manuale di istruzioni consente al personale di prendere
dimestichezza con un funzionamento sicuro, e con procedure di
manutenzione adeguate per il rilevatore digitale GT-16.
Tenere questo manuale a disposizione di tutto il personale. Altre copie di
questo manuale sono disponibili gratuitamente su richiesta al sito
www.greenlee.com.
Non smaltire o gettare questo prodotto! Per informazioni
sul riciclaggio, andare al sito www.greenlee.com.
Tutte le specifiche sono nominali e potrebbero cambiare man mano che si
apportano migliorie al design. La Greenlee Textron Inc. non sarà responsabile
di eventuali danni risultanti dall’errata applicazione o dall’uso improprio dei
suoi prodotti.
® Modello depositato: il colore verde degli strumenti di misura elettrica è un
marchio depositato della Greenlee Textron Inc.
Romex è un marchio depositato della General Cable Industries, Incorporated.
Simboli sull’unità
Avvertenza — Leggere il manuale di istruzioni.
Rischio di folgorazione
Doppio isolamento
Importanti informazioni per la sicurezza
Leggere e comprendere questo materiale
prima di azionare o di riparare l’apparecchiatura.
La mancata comprensione della modalità di
funzionamento sicura di questo attrezzo può
causare incidenti, gravi lesioni a persone o morte.
Pericolo di scossa elettrica:
Il contatto con i circuiti sotto tensione può causare
gravi lesioni o morte.
Pericolo di scossa elettrica:
• Non presumere che l’indicazione di mancanza di tensione
voglia dire che il circuito non è alimentato.
• Attenersi al metodo di sicurezza a 3 punti, come descritto
nella sezione Funzionamento (fasi 2, 3 e 4).
• Non usare questa unità se bagnata o danneggiata.
• Non applicare più della tensione nominale tra la punta della sonda
e la messa a terra.
• Non azionare con la custodia aperta.
• Questo multimetro non rileva tensione attraverso un condotto
metallico, su cavo alimentato o schermato, o su cavo non
metallico senza guaina saturato con acqua, o a distanze quali ad
esempio pareti.
• L’utilizzo di questa unità in prossimità di apparecchiature che
generano interferenze elettromagnetiche può causare letture non
stabili o imprecise.
L’inosservanza di queste avvertenze potrebbe causare gravi infortuni
personali o la morte.
Pericolo di scossa elettrica:
• Non tentare di riparare questa unità. Non contiene parti riparabili
dall’utente.
• Non esporre questa unità a temperature estreme o alta umidità.
Consultare le “Specifiche”.
La mancata osservanza di queste precauzioni può causare lesioni a
persone o danni all’unità.
Détecteur de tension GT-16
52058081 © 2011 Greenlee Textron Inc. 1/11
Description
Le détecteur de tension GT-16 de Greenlee est conçu pour vérifier
la présence de tension c.a. et indique celle-ci à l’utilisateur par
une tonalité intermittente et une DEL clignotante. La DEL clignote à
intervalles réguliers pour indiquer l’état de la pile.
Sécurité
Lors de l’utilisation et de l’entretien des outils et des équipements de
Greenlee, votre sécurité est une priorité. Ce manuel d’instructions et
toute étiquette sur l’outil fournit des informations permettant d’éviter
des dangers ou des manipulations dangereuses liées à l’utilisation de
cet outil. Suivre toutes les consignes de sécurité indiquées.
Dessein de ce manuel
Ce manuel d’instructions est conçu pour que le personnel puisse se
familiariser avec le fonctionnement et les procédures d’entretien sûres
du détecteur de tension GT-16 de Greenlee.
Mettre ce manuel à la disposition de tous les employés. On peut obtenir
des exemplaires gratuits sur simple demande sur le site Web
www.greenlee.com.
Ne pas se débarrasser de ce produit ou le jeter ! Pour des
informations sur le recyclage, visiter www.greenlee.com.
Toutes les spécifications sont nominales et peuvent changer avec
l’amélioration de la conception. Greenlee Textron Inc. ne peut être tenue
responsable des dommages résultant d’une application inappropriée ou d’un
mauvais usage de ses produits.
® Enregistré : La couleur verte des instruments de vérification électrique est
une marque de commerce déposée de Greenlee Textron Inc.
Romex est une marque déposée de General Cable Industries, Incorporated.
Symboles apparaissant sur l’appareil
Avertissement — Lire le manuel d’instructions
Risques de décharge électrique
Isolation double
Consignes de sécurité importantes
Lire attentivement et bien comprendre cette
documentation avant d’utiliser ou de procéder
à l’entretien de cet équipement. Négliger de
comprendre comment utiliser cet outil en toute
sécurité pourrait provoquer un accident et entraîner
des blessures graves, voire mortelles.
Risque de décharge électrique :
Un contact avec des circuits sous tension pourrait
entraîner des blessures graves, voire mortelles.
Risque de décharge électrique :
• Ne pas supposer qu’une absence d’indication de tension
signifie que le circuit n’est pas sous tension.
• Suivre la méthode de sécurité en 3 étapes décrite dans la
section « Utilisation » (étapes 2, 3 et 4).
• Ne pas utiliser cet appareil s’il est mouillé ou endommagé.
• Ne pas appliquer plus que la tension nominale entre l’embout et
la prise de terre.
• Ne pas utiliser lorsque le boîtier est ouvert.
• Ce vérificateur ne détecte pas la tension au travers d’un conduit
en métal, d'un câble blindé ou d’un câble non métallique revêtu
d’une gaine et saturé d’eau, ou encore à distance, comme au
travers des murs.
• L’utilisation de cet appareil à proximité d’équipements qui
génèrent des interférences électromagnétiques peut produire des
lectures instables ou erronées.
L’inobservation de ces consignes pourrait entraîner des blessures
graves, voire mortelles.
Risque de décharge électrique :
• Ne pas tenter de réparer cet appareil. Il ne comporte aucune pièce
pouvant être réparée.
• Ne pas exposer l’appareil à des températures ou à une humidité
extrêmes. Se reporter à la section des « Spécifications ».
L’inobservation de ces consignes pourrait endommager l’appareil et
entraîner des blessures.
2
Operation
The Greenlee GT-16 is useful for identifying hot and neutral conductors,
finding a break in a wire, and detecting the presence of AC voltage
at outlets, switches, circuit breakers, fuses, and wires and cables,
including Romex
®
.
Note: Round cords may have twisted conductors. Check for hot
conductors by sliding the unit along the cord.
Note: The GT-16 can be used to find a break in a wire:
• To find a break in a hot conductor, trace the wire until the signal
stops.
• To find a break in a neutral conductor, connect a load between the hot
and neutral. Trace the wire until the signal stops.
1. Turn the unit on by rotating the sensitivity adjustment thumbwheel
away from the OFF position. Verify that the LED flashes periodically.
If the LED does not flash, the battery is not working and needs to be
replaced.
2. Test the unit on a known live circuit before each use.
• If the unit does not function as expected on a known live circuit,
replace the battery.
• If the unit still does not function as expected, call Greenlee for
technical assistance at 800-435-0786.
3. Place the tip on or near the circuit or unit to be tested. Tone and
flashing LED indicate the presence of voltage (5 VAC to 1000 VAC).
• Use maximum sensitivity to detect low voltages.
• Reduce sensitivity to find breaks in wires or to identify hot and
neutral conductors.
4. Test again on a known live circuit after use to verify proper
operation.
Specifications
Indicators: LED and Tone
Voltage Range: 5 VAC to 1000 VAC
Frequency Range: 50 Hz to 500 Hz
Measurement Category: Category IV, 1000 V per UL 61010
Operating Conditions:
Temperature: 0 °C to 40 °C (32 °F to 104 °F)
Less than 80% relative humidity (noncondensing)
Altitude: 2000 m (6500’) maximum
Indoor use only.
Pollution Degree: 2
Battery: One 1.5 volt battery (AAA, NEDA 24A or IEC LR03)
Measurement Categories
This definition was derived from the international safety standard for
insulation coordination as it applies to measurement, control, and
laboratory equipment. These measurement categories are explained in
more detail by the International Electrotechnical Commission; refer to
either of their publications: IEC 61010-1 or IEC 60664.
Measurement Category IV: Primary supply level. Overhead lines
and other cable systems. Some examples include cables, meters,
transformers, and other exterior equipment owned by the power utility.
Maintenance
Battery Replacement
1. Disconnect the unit from the circuit.
2. Rotate the outer battery cap clockwise and remove it.
3. Rotate the metal inner cap and remove it.
4. Replace the battery (observe polarity).
5. Replace the metal inner cap.
6. Replace the outer battery cap.
Tip
On-Off/Sensitivity Adjustment Thumbwheel
Inner Metal Cap
Battery Cap
Cleaning
Periodically wipe the case with a damp cloth and mild detergent;
do not use abrasives or solvents.
Statement of Conformity
Greenlee Textron Inc. is certified in accordance with ISO 9001 (2000) for
our Quality Management Systems.
The instrument enclosed has been checked and/or calibrated using
equipment that is traceable to the National Institute for Standards and
Technology (NIST).
Lifetime Limited Warranty
Greenlee Textron Inc. warrants to the original purchaser of these goods
for use that these products will be free from defects in workmanship
and material for their useful life, excepting normal wear and abuse.
This warranty is subject to the same terms and conditions contained in
Greenlee Textron Inc.’s standard one-year limited warranty.
For all Test Instrument repairs, contact Customer Service at
800-435-0786 and request a Return Authorization.
For items not covered under warranty (such as items dropped, abused,
etc.), a repair cost quote is available upon request.
Note: Prior to returning any test instrument, please check replaceable
batteries or make sure the battery is at full charge.
Funzionamento
L’unità Greenlee GT-16 è utile per l’identificazione di conduttori sotto
tensione e neutri, per rilevare un’interruzione in un filo e per rilevare la
presenza di tensione c.a. in prossimità di prese, interruttori, interruttori
automatici, fili e cavi, inclusi Romex
®
.
Nota: le corde rotonde potrebbero avere conduttori intrecciati.
Controllare l’esistenza di conduttori sotto tensione facendo
scorrere l’unità lungo la corda.
Nota: l’unità GT-16 può essere usata per rilevare un’interruzione in un
filo:
• Per rilevare un’interruzione in un conduttore sotto tensione, tracciare
il filo fino all’arresto del segnale.
• Per rilevare un’interruzione in un conduttore neutro, collegare un
carico tra il punto sotto tensione ed il neutro. Tracciare il filo fino
all’arresto del segnale.
1. Accendere l’unità ruotando la rotellina di regolazione della sensibilità
nella direzione opposta a OFF. Accertarsi che la spia LED lampeggi
periodicamente. Se la spia LED non lampeggia, la pila non funziona
e occorre restituirla.
2. Prima dell’uso, collaudare l’unità su un circuito di cui si sia
accertato il funzionamento.
• Se l’unità non funziona come previsto su un circuito di cui si sia
accertato il funzionamento, sostituire la pila.
• Se l’unità continua a non funzionare come previsto, rivolgersi
alla Greenlee per assistenza chiamando il numero verde
800-435-0786.
3. Posizionare la punta della sonda sul circuito o unità da collaudare,
o in prossimità degli stessi. Il segnale acustico e la spia LED
lampeggiante indicano la presenza di tensione
(da 5 V c.a. a 1000 V c.a.).
• Usare la massima sensibilità per rilevare basse tensioni.
• Ridurre la sensibilità per rilevare interruzioni nei fili o identificare
conduttori caldi o neutri.
4. Dopo ogni utilizzo, ricollaudare su un circuito alimentato noto, per
verificarne il corretto funzionamento.
Specifiche
Spie: LED e segnale acustico
Gamma di tensione: da 5 V c.a. a 1.000 V c.a.
Gamma di frequenza: da 50 Hz a 500 Hz
Categoria di misura: Categoria IV, 1000 V per IEC 61010
Condizioni operative:
Temperatura: da 0 a 40 °C (da 32 a 104 °F)
Umidità relativa inferiore all’80% (senza condensa)
Altitudine: massimo di 2000 m (6500 piedi)
Solo per interni.
Livello di inquinamento: 2
Pile: due pile da 1,5 volt (AAA, NEDA 24A o IEC LR03)
Categorie di misura
Questa definizione deriva dallo standard internazionale sulla sicurezza
per la coordinazione dell’isolamento per le apparecchiature di misura,
controllo e laboratorio. Queste categorie di misura vengono spiegate nei
dettagli dall’International Electrotechnical Commission; consultare la
documentazione: IEC 61010-1 or IEC 60664.
Categoria di misura IV: Livello forniture primarie. Linee sospese ed
altri sistemi di cablaggio. Tra gli esempi compaiono cavi, multimetri,
trasformatori ed altre apparecchiature esterne collegate all’utility di
alimentazione.
Manutenzione
Sostituzione delle pile
1. Scollegare l’unità dal circuito.
2. Ruotare il cappuccio pile esterno in senso orario e toglierlo.
3. Ruotare il cappuccio metallico interno e rimuoverlo.
4. Sostituire la pila (osservarne la polarità).
5. Rimontare il cappuccio interno metallico.
6. Rimontare il cappuccio pile esterno.
Punta
Rotellina di regolazione sensibilità/On-Off
Cappuccio interno metallico
Cappuccio pile
Pulitura
Pulire periodicamente la custodia con un panno umido e detergente
neutro; non usare abrasivi o solventi.
Dichiarazione di conformità
Greenlee Textron Inc. è una società certificata ISO 9001 (2000) per i
nostri sistemi di gestione della qualità.
Lo strumento contenuto è stato controllato e/o calibrato usando
apparecchiatura registrata presso il National Institute for Standards and
Technology (NIST).
Garanzia limitata a vita
Greenlee Textron Inc. garantisce all’acquirente originale di questi
prodotti che l’uso degli stessi sarà libero da difetti di manodopera e
materiale per la loro vita utile, ad eccezione di usura naturale ed abuso.
Questa garanzia è soggetta alle stesse condizioni contenute nella
garanzia limitata di un anno, standard della Greenlee Textron Inc.
Per la riparazione di tutti gli strumenti di collaudo, rivolgersi al reparto
Assistenza clienti al numero 800-435-0786 e richiedere un numero di
autorizzazione per la restituzione.
Per le parti non coperte dalla garanzia (quali componenti caduti o
utilizzati in modo erroneo), è disponibile su richiesta un preventivo di
riparazione con addebito.
Nota: prima di restituire uno strumento di collaudo, controllare le pile o
accertarsi che siano completamente cariche.
Utilisation
Le GT-16 de Greenlee est utile pour repérer les fils de phase et neutres,
détecter des fissures de fil et la présence de tension c.a. dans les prises,
les interrupteurs, les disjoncteurs, les fusibles, les fils et les câbles, y
compris Romex
®
.
Remarque : Les cordons ronds peuvent contenir des fils torsadés.
Vérifier s’il y a des fils de phase en faisant glisser l’appareil le long
du cordon.
Remarque : Le GT-16 peut être utilisé pour détecter une fissure dans
un fil :
• Pour détecter une fissure dans un fil de phase, suivre le fil jusqu’à ce
que le signal s’arrête.
• Pour détecter une fissure dans un fil neutre, connecter une charge
entre la phase et le neutre. Suivre le fil jusqu’à ce que le signal
s’arrête.
1. Activer l’appareil en faisant tourner la molette de réglage de
sensibilité pour l’éloigner de la position d’arrêt (OFF). Vérifier que
la DEL clignote régulièrement. Si la DEL ne clignote pas, la pile ne
fonctionne pas et doit être remplacée.
2. Vérifier l’appareil sur un circuit sous tension connu avant
chaque utilisation.
• Si l’appareil ne fonctionne pas comme prévu sur un circuit sous
tension dont le fonctionnement est connu, remplacer la pile.
• Si l’appareil ne fonctionne toujours pas comme prévu, appeler
Greenlee pour obtenir de l’assistance technique au
800 435-0786.
3. Placer le bout sur ou à proximité du circuit ou de l’appareil à vérifier.
La tonalité et la DEL clignotante indiquent la présence de tension
(5 à 1000 V c.a.).
• Utiliser la sensibilité maximale pour détecter des faibles tensions.
• Réduire la sensibilité pour détecter des fissures dans les fils ou
identifier des fils de phase et de neutre.
4. Vérifier de nouveau sur un circuit sous tension connu pour s’assurer
du bon fonctionnement.
Spécifications
Indicateurs : DEL et tonalité
Plage de tension : 5 à 1000 V c.a.
Plage de fréquences : 50 à 500 Hz
Catégorie de mesure : Catégorie IV, 1000 V selon UL-61010
Conditions d’utilisation :
Température : 0 à 40 °C (32 à 104 °F)
Moins de 80 % d’humidité relative (sans condensation)
Altitude : 2000 m (6500 pi) maximum
Utilisation à l’intérieur uniquement.
Degré de pollution : 2
Pile : Une pile de 1,5 volt (AAA, NEDA 24 A ou IEC LR03)
Catégories de mesure
Cette définition est dérivée des normes internationales sur la sécurité
pour la coordination de l’isolation telle qu’elle s’applique à la mesure,
au contrôle et à l’équipement de laboratoire. Ces catégories de mesure
sont expliquées plus en détail par la Commission électrotechnique
internationale ; se reporter à l’une de ces deux publications :
IEC 61010-1 ou IEC 60664.
Catégorie de mesure IV : Niveau d’alimentation principal. Lignes
surélevées et autres systèmes de câbles. Par exemple, les câbles,
les compteurs, les transformateurs et autres équipements extérieurs
appartenant aux fournisseurs en électricité.
Entretien
Remplacement de la ou des piles
1. Débrancher l’appareil du circuit.
2. Faire tourner le capuchon de pile dans le sens horaire et l’enlever.
3. Faire tourner le capuchon interne et l’enlever.
4. Remplacer la pile (suivre la polarité).
5. Remettre en place le capuchon interne.
6. Remettre en place le capuchon externe de la pile.
Conseil
Molette de marche-arrêt/réglage de sensibilité
Capuchon interne en métal
Capuchon de la pile
Nettoyage
Nettoyer régulièrement le boîtier avec un chiffon humide et un détergent
doux. Ne pas utiliser de produits abrasifs ou de solvants.
Déclaration de conformité
Greenlee Textron Inc. est certifiée selon ISO 9001 (2000) pour nos
Systèmes de gestion de la qualité.
L’instrument ci-inclus a été vérifié et/ou étalonné avec des moyens de
mesure raccordés aux étalons du National Institute of Standards and
Technology (NIST).
Garantie à vie limitée
La société Greenlee Textron Inc. garantit à l’acheteur d’origine de ces
produits que ces derniers ne comportent aucun défaut d’exécution ou
de matériau pour la durée de leur vie utile, sauf l’usure normale. Cette
garantie est assujettie aux mêmes conditions que celles contenues dans
les modalités et conditions de la garantie limitée standard d’un an de
Greenlee Textron Inc.
Pour toutes les réparations d’instruments de mesure, appeler le service
après vente au 800 435-0786 et demander une autorisation de retour.
Lorsque les articles ne sont pas protégés par une garantie (comme si
l’appareil tombe, s’il est soumis à un usage abusif, etc.), une soumission
pour le prix de réparation sera présentée sur demande.
Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier
les piles remplaçables ou vous assurer que la batterie est complètement
chargée.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Greenlee GT-16 Manuel utilisateur

Catégorie
Compteurs d'électricité
Taper
Manuel utilisateur
Ce manuel convient également à