DCS 221712 Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

THE PROFESSIONAL ISLAND VENT HOOD
Installation Guide
MODELS:
IVS40
IVS52
RDS-364GD
1
APPROVED FOR RESIDENTIAL APPLIANCES AND RESIDENTIAL USE ONLY.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
Installation must comply with all local codes.
Thank you for selecting this DCS Professional Island Vent Hood. Because of this appliances unique features
we have developed this Installation Guide. It contains valuable information on how to properly install your
new appliance for years of safe and enjoyable cooking.
F
or your convenience, product questions can be answered by a DCS Customer Care Representative by
phone: 1-888-936-7872, or email: customer[email protected].
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
A MESSAGE TO OUR CUSTOMERS
NOTE: Please write the Model, Code, and Serial Numbers on this page for references (located on the
inside of the top panel on the left, behind the rear back filter, above the motor assembly)
MODEL NUMBER CODE SERIAL NUMBER
NOTE: Inspect the product to verify that there is no shipping damage. If any damage is detected,
call the shipper and initiate a damage claim. DCS by Fisher & Paykel is not responsible for shipping
damage
.
DO NOT discard any packing material (box, pallet, straps) until the unit has been inspected.
WARNING
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
death.
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
DANGER
If You Smell Gas:
Do not try to light any appliance.
Do not t
ouch an
y elec
trical swit
ch; do not use an
y phone in y
our
building.
Immediately call your gas supplier from a neighbors phone. Follow
the gas supplier’s instructions.
I
f you cannot reach your gas supplier, call the fire department.
I
nstallation and service must be performed by a qualified installer,
service agency or the gas supplier.
TABLE OF CONTENTS
2
SAFETY PRACTICES .....................................................................................................................................................3-4
PARTS ........................................................................................................................................................................................5
BEFORE INSTALLING HOOD .................................................................................................................................6-8
INSTALLATION...............................................................................................................................................................9-16
HOW TO OBTAIN SERVICE........................................................................................................................................17
WARRANTY....................................................................................................................................................................18-19
A MESSAGE TO OUR CUSTOMERS
SAFETY WARNING:
Turn off power circuit at service panel and lock out panel, before wiring this
a
ppliance.
Requirement: 120 V AC, 60 Hz. 15 A Branch Circuit
WARNING
To reduce the risk of injury to persons in the event of a rangetop grease fire,
observe the following: Turn burner off first. Smother flames with a close-
fitting lid, cookie sheet, or metal tray. Be careful to prevent burns. If the
flames do not go out immediately evacuate and call the fire department.
Never pick up a flaming pan - You may be burned. DO NOT USE WATER,
including wet dishcloths or towels - a violent steam explosion will result.
Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already
know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
.
SAFETY PRACTICES AND PRECAUTIONS
3
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials or vapors.
WARNING:
To reduce the risk of a range top grease fire:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oil slowly on low or medium settings.
B. Always turn venthood “ON” when cooking at high heat or when flambeing foods (i.e. Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface unit.
Make-Up air may be necessary to prevent air flowing down chimney, or through unsealed door,
window, or fireplace opening.
WARNING:
To reduce the risk of fire, electrical shock, or injury to persons, observe the
following guidelines.
A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact
the manufacturer.
B. Before servicing or cleaning the unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disc
onnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
C. Installation and electrical wiring must be performed by qualified personnel in accordance with
all applicable codes & standards, including fire-rated construction.
D. To prevent backdrafting, sufficient air is needed to maintain proper combustion and safe
exhausting of gases thr
ough the flue (chimney) of fuel bur
ning equipmen
t. Follow the heating
equipmen
t manufac
tur
ers guideline and saf
ety standards such as those published by the
National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration
and Air C
onditioning Eng
ineers (
ASHRAE), and the local code authorities.
E. Use caution when cutting or drilling into walls or ceilings as not to damage electrical wiring
and other hidden utilities.
SAFETY PRACTICES & PRECAUTIONS
4
WARNING:
To reduce the risk of fire and to properly exhaust air, be sure to duct air to
o
utside. Do not vent exhaust air into spaces within walls or ceiling, nor into
attics, crawl spaces, or garages.
NOTE: Unit MUST be vented to the outside of the building.
IMPORTANT: Refer to ducting information supplied in this manual.
WARNING:
To reduce the risk of electrical shock or injury to persons, all vent hoods
must be installed with ventilators that have been approved for use with the
hood.
WARNING:
To reduce the risk of fire, use only metal duct work.
Install this hood in accordance with all requirements specified.
WARNING:
To reduce the risk of fire or electric shock, do not use this hood with any
external solid state speed control device.
WARNING:
To reduce the risk of injury to persons in the event of a rangetop grease fire,
observe the following: Turn burner off first. Smother flames with a close-
fitting lid, cookie sheet, or metal tray. Be careful to prevent burns. If the
flames do not go out immediately evacuate and call the fire department.
Never pick up a flaming pan - You may be burned. DO NOT USE WATER,
including w
et dishcloths or t
o
w
els - a violent steam explosion will result.
Use an extinguisher ONLY if:
1) Y
ou k
now you have a Class ABC extinguisher, and you already
know how to operate it.
2)
T
he fir
e is small and contained in the area where it started.
3)
T
he fire department is being called.
4) Y
ou can figh
t the fir
e with y
our back t
o an exit.
WARNING:
To reduce the risk of fire, electrical shock, or injury to persons, the Island
Hood (IV
S40/52) must be installed with the chimney struc
ture (IVCK)
supplied in the separate box. Custom parts cannot be substituted.
5
PARTS
PARTS INCLUDED WITH YOUR HOOD
Hood canopy assembly with light bulbs installed.
Metal transition with back draft dampers
Use & Care/Installation Instructions
Filters (quantity depending on model and size)
Screws
Integral blowers
4 side baffle trims (IVS52 only)
Baffle filter panel
PARTS NOT INCLUDED WITH YOUR HOOD
Duct tape
1/2" conduit
Wire nuts
Hood chimney structure and duct covers. Those items are included with accessory kit model
IVCK, which must be ordered separately.
6
BEFORE INSTALLING HOOD
1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible.
CAUTION:
Vent unit to outside of building only.
2. Two people are necessary for installation.
3. The hood is fitted with screws suitable for most surfaces. Consult a qualified installer. Check if they
perfectly fit with your ceiling.
4. Do not use flex ducting.
5. COLD WEATHER installations should have an additional backdraft damper installed to minimize
back flow of cold air and a nonmetallic thermal break to minimize conduction of outside temper-
atures as part of the ductwork. The damper should be on the cold air side (outside wall) of the
thermal break.
The break should be as close as possible to where the ducting enters the heated portion of the
house.
6. Hood installation height above cooktop/range is the users preference. Lower installation heights
will improve the efficiency of capturing cooking odors, grease, and smoke. These hoods have been
approved for installation heights 30” and above the cooktop/ranges. Taller people may find a 30”
installation height is inconvenient. DCS recommends an installation height between 30” and 36”.
7. For installation over DCS range and cooktop models RGS-364GL or CS-364GL, the IVS52 model
venthood is recommended.
8. Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted
Ventilation Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult your HVAC professional for specific
requirements in your area.
7
BEFORE INSTALLING HOOD
TYPICAL INSTALLATION
A typical hood installation is shown below in Figure 1. When installed with the IVCK chimney
accessory kit, the hood can be installed at a height of 30” to 36” in kitchens with ceiling heights
ranging from 8-1/2 to 10 feet. Installatons outside this range will require custom framing. Consult a
qulified installer for a custom framing solution.
DUCTING
Provide a 10” Round Duct. Ducting run cannot exceed 40 feet, including allowance for elbows/tran-
sitions.
ELECTRICAL
Install a 1/2” conduit from the service panel long enough to reach the hood once it is installed.
Power supply must be rated for 120V 60Hz, 15 amps (minimum).
INSTALLATION HEIGHT CALCULATIONS
See Figure 1.
a) Select a hood installation height C that is comfortable for the user. (30”to 36”
recommended, 30” minimum).
b) Calculate chimney cover height E using fomrula below.
Save this calculation for use later in the installation.
A = Kitchen Ceiling Height
B= Counter Height (36" standard)
C= Installation Height of Hood.
D= Canopy Height = 13”
E= Chimney cover height = A – B – C – D
NO
TE: Chimney c
o
v
er heigh
t can be adjusted
from 24-1/2" to 36" to meet your desired
hood installation height.
FIG.1
A
B
C
D
E
8
BEFORE INSTALLING HOOD
CEILING PREPARATION
Installing supports above ceiling drywall.
NOTE: Take into consideration the hood depth; some models are much deeper than the cook
top.
NOTE: The following steps pertain to hood installation using chimney structure/duct cover kit
model IVCK. Other installations may require custom framing, etc. Consult a qualified
installer.
1. Mark center lines of cooktop or range on ceiling above. Use
centerlines marked on ceiling to position the mounting
template. Location of front arrow on the template must point
towards front of cooking surface. Mark mounting holes
indicated on the template.
2. Remove and save template. Cut and remove ceiling drywall.
Install suitable length 2" x 4" lumber between joists to provide
chimney mounting points as shown in Fig. 2. Use template for
dimensions and required clearance.
Make sure to affix the added lumber firmly and level. Consult a
professional if you have difficulties or your installation is
unique. Consult template and Fig. 2.
IMPORTANT:
The ceiling structure (joists and
lumbers) must be capable of supporting
the weight of the hood (approximately
110 lbs for 40” range hood and 143 lbs
for 52” range hood) and any inadvertent
user contact loads.
3. DUCT INSTALLATION
F
or IVS
-52: I
nstall 10”
exhaust duc
t and ex
tend length
E minus 4-5/8” (E – 4-5/8”) from ceiling.
See Fig. 1. Do not use duct smaller than specified.
4. Install 1/2" electrical conduit in location marked on template
and ex
t
end length E minus 3-1/8”
(E – 3-1/8”) from ceiling (use formula in Fig . 1).
5. Install drywall around duct and conduit; then refinish ceiling.
6.
T
ape template in place using centerlines marked in Step 1. Mark
locations of mounting points. Remove template.
FIG.2
9
INSTALLATION
HOOD INSTALLATION
1. Adjust chimney mounting structure to E + 3/8” dimension as determined in installation height
c
alculation on page 7. Use 2 screws per attachment leg, see Fig. 3.
2. To install Chimney Structure to ceiling, use a 10mm or adjustable wrench or flat head screwdriver.
a. Drill pilot holes into ceiling at fixing
points as determined in Step 6 under
Ceiling Preparation (Pg. 8).
b. Screw the 4 lag screws provided (see
Fig. 4, do not tighten completely).
c. Attach mounting structure to joists with
the 4 lag screws provided. (see Fig. 4,
keep 10” duct inside structure) .
ATTENTION: Junction Box on the chim
ney structure should be oriented to the
right side when facing the front of the
cooktop.
d. Tighten the 4 lag screws, see Fig. 4.
Junction
Box
Attachment
Leg
Fixing
point
Leg
screw
10" Duct
1/2" Conduit
Ceiling
Chimney
Structure
FIG.3
FIG.4
10
INSTALLATION
3. Assembly of the 10”Transition.
The transition supplied with the hood mounts to the top
o
f the hood, Figure 5.
a. Place the transition piece over the hood exhaust
and secure with 4 screws provided.
b. Duct tape connection between transition and
hood.
c. Remove tape holding damper.
4. Check that the screws on bottom of chimney structure
are partially screwed into place; these will serve to hang
and fix the canopy.
5. If already mounted in place remove all grease filters.
6. Back out the hanging screws on the bottom of the
chimney structure to 1/4” gap.
Lift the canopy up to the chimney support .
Carefully align the canopy keyhole to the screws on the
chimney support.
Slide the hood to engage the keyhole slots. See Fig. 6.
7. Tighten screws securely (from inside the canopy). Fix
canopy to structure with 4 screws from inside the
canopy. See Fig. 7.
8. Make final angular adjustment to unit at ceiling if necessary, then finish installation adding two
fixing screws. See Fig. 8.
additional
fixing screw
Duct
Transition
Top
o
f
H
oo
d
Screw
FIG.5
FIG.6
FIG.7
FIG.8
11
INSTALLATION
9
. Ducting: There should be no more than 1"
g
ap between canopy transition and house
d
ucting. Adjust starting collar over both
ducts. Tighten collar. Fasten duct with
screws and tape per code. Screws must not
hamper the damper. See Fig. 9.
INTEGRAL VENTILATOR INSTALLATION
(see Fig. 10 to 11)
1. The Integral ventilator can be mounted to
discharge air towards the ceiling. So motor
connector may be located frontwards.
From the inside of the hood, slip motor into
the bracket on the left.
Rotate motor upwards until it snaps into the
spring clip on the right.
Secure the motor to the hood with the
machine screw and lock washer.
Plug connector into the motor, Fig. 11.
FIG. 10
Spring Clip
Outlet
Bracket
Motor Connector
Spring Clip
Motor
support
Fixing
point
Fixing
point
Bracket
Integral ventilator for 40" Hood
10" Duct
C
ollar
Transition
S
From Control
Panel
Motor connector
FIG. 9
FIG. 11
INSTALLATION
12
2. Snap the central baffle filter panel into the place so the both rails engage with side pins on both
s
ides of hood. Drive 2 screws (1 on each side ) through baffle filter panel hole to hood. See
Fig. 12.
3. Snap four-side baffle trim to hood (4 pins engage each side trim). The baffle trims are supplied
separately (for IVS52 only). See Fig. 13.
4. Install all baffle filters as per Use and Care Manual instructions.
Fig. 12
F
ig
. 13
Baffle filter panel
Baffle trim
13
INSTALLATION
WIRING TO POWER SUPPLY
WARNING:
T
urn off power circuit at the service panel before wiring this unit.
120 VAC, 15 Amp circuit required.
1. Remove j-box cover as shown in Fig. 14.
2. Remove the knockout and install the strain relief (conduit) connector (1/2") in junction box.
3. Run 3 wires; black, white and green (#14 AWG) in 1/2" conduit from service panel to junction box.
4. Connect black wire from service panel to black or red in junction box, white to white and green
to green-yellow. See Fig. 14.
5. Close junction box cover.
6. Plug cable at the top of the hood into the junction box connector.
7. Check all light bulbs to make sure they are secure in their sockets, then turn power on in service
panel and check lights and blower operation per Care & Use manual and install drip tray support
and filters.
FIG. 14
From Control
Panel
Junction
Box
1/2"
Conduit
Junction
Box
Cover
14
INSTALLATION
FINAL ASSEMBLY
For final Chimney Cover installation, DO NOT USE ELECTRIC SCREW DRIVER.
NOTE: Overtightening screws can deform metal.
1. Install the cage nuts from inside the rectangular slots supplied with top and bottom duct covers.
See Fig. 15.
A total of 14 nuts must be fitted.
x
Duct cover
Top section
Duct cover
bottom section
Duct cover
Top section
Duct cover
bottom section
Duct cover
Top section
FIG. 15
15
INSTALLATION
2. Install the two brackets to the chimney structure supplied with the kit by using one screw each
side.
3. Join the two top sections of the duct cover.
Screw the two sections together with 8 screws (4 each side- see the top view in Fig. 16 for
joining the two sections).
4. Install the top duct cover assembly to the bracket, near the ceiling, with two screws (one each
side).
Bracket
Duct cover
Top section
Duct cover
Top section
Bracket
Screw
Fix to the top
Top Duct
assembly
Diagram
Drive a #10 x 2-1/4"
screw into wood
framing above
ceiling. This screw
supports the load of
the upper chimney
duct cover. One
screw each side.
FIG. 16
16
INSTALLATION
5
. Join the two bottom sections of the duct cover which covers the chimney structure using 6
screws, (3 each side, see Fig. 17 for the plan diagram for joining the two sections).
6. Insert the bottom section of the duct cover in its seat so that it completely covers the chimney
s
tructure.
7. Install the 4 supplied trims for duct cover channels to cover the fasteners of the bottom duct
covers. (CAUTION! THE BOTTOM FLUE TRIMS ARE THE NARROWER AND SHALLOWER ONES).
The wider and deeper trims are those used for the top flue, and must be cut to size.
If necessary, slightly expand the trims to ensure their adherence to the flue.
8. Turn the power on again at the electrical panel and check for correct hood operation.
9. Make sure to leave this
manual for the home owner.
D
uct cover
Rear Bottom
s
ection
Duct cover
Front Bottom
section
Bottom Duct
assembly
Diagram
Screw
X
X
Tabs
FIG. 17
17
HOW TO OBTAIN SERVICE
BEFORE YOU CALL FOR SERVICE
I
s the circuit breaker tripped or the fuse blown?
I
s there a power outage in the area?
For warranty service, contact DCS Customer Care Representative at (888) 936-7872. Before you call,
please have the following information ready:
Model Number
(located on the inside of the top panel on the left, behind the rear back
filter, above the motor assembly)
Serial Number
(located on the inside of the top panel on the left, behind the rear back
filter, above the motor assembly)
Code
(located on the inside of the top panel on the left, behind the rear back
filter, above the motor assembly)
Date of installation
A brief description of the problem
Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction,
please call, write or email us at:
Write:
Fisher & Paykel Appliances, Inc.
Attention: DCS Customer Care
5900 Skylab Road
Huntington Beach, CA 92647
email: customer[email protected]
18
WARRANTY
LIMITED WARRANTY
When you purchase a new DCS Ventilation Product for personal or consumer use you automatically
receive a One year Limited Warranty covering parts and labor for the entire product, and a Five year
Limited Warranty on the switches and motor (parts only) for servicing within the 48 mainland United
States, Hawaii, Washington D.C and Canada. In Alaska the Limited Warranty is the same except that you
must pay to ship the Product to the service shop or for the service technicians travel to your home.
Products for use in Canada must be purchased through the Canadian distribution channel to ensure
regulatory compliance.
If the Product is installed in a motor vehicle, boat or similar mobile facility, you receive the same One
year Limited Warranty, but you must bring the vehicle, boat or mobile facility containing the Product
to the service shop at your expense or pay the service technicians travel to the location of the Product.
FISHER & PAYKEL UNDERTAKES TO:
Repair without cost to the owner either for material or labor any part of the Product, the serial number
of which appears on the Product, which is found to be defective. In Alaska, you must pay to ship the
Product to the service shop or for the service technicians travel to your home. If the Product is installed
in a motor vehicle, boat or similar mobile facility, you must bring it to the service shop at your expense
or pay for the service technicians travel to the location of the Product. If we are unable to repair a
defective part of the Product after a reasonable number of attempts, at our option we may replace the
part or the Product, or we may provide you a full refund of the purchase price of the Product (not
including installation or other charges).
This warranty extends to the original purchaser and any succeeding owner of the Product for products
purchased for ordinary single-family home use. All service under this Limited Warranty shall be
provided by Fisher & Paykel Appliances, Inc. or its Authorized DCS Service Agent during normal
business hours.
HOW LONG DOES THIS LIMITED WARRANTY LAST?
Our liability under this Limited Warranty for the entire product expires One Year from the date of
purchase of the Product by the first consumer. Our liability under this Limited Warranty for the
switches and motor (parts only) expires Five Years from the date of purchase of the Product by the first
consumer.
Our liabilit
y under an
y implied w
ar
ranties, including the implied warranty of merchantability (an
unwritten warranty that the Product is fit for ordinary use) also expires One Year (or such longer period
as required by applicable law) from the date of purchase of the Product by the first consumer. Some
states do not allow limitations on how long an implied warranty lasts, so this limit on implied
warranties may not apply to you.
THIS WARRANTY DOES NOT COVER:
A. Service calls that are not related to any defect in the Product. The cost of a service call will be
charged if the problem is not found to be a defect of the Product. For example:
1.
C
orrect faulty installation of the Product.
2. Instruct you how to use the Product.
3. Replace house fuses, reset circuit breakers, correct house wiring or plumbing, or replace light
bulbs.
4. Correct fault(s) caused by the user.
5. Change the set-up of the Product.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48