Midmark 641 Power Procedures Chair Mode d'emploi

Taper
Mode d'emploi
Users Guide
Wireless Hand / Foot Controls
9A408
This guide outlines basic operation of the
wireless hand / foot control accessory.
If service is required, contact your authorized
Midmark dealer.
Dealer (name / phone):
__________________________________
__________________________________
__________________________________
__________________________________
Date of Purchase: __________________
Midmark Corporation
60 Vista Drive
Versailles, OH 45380-0286
Phone: 937-526-3662
Fax: 937-526-5542
www.midmark.com
General Information
© Midmark Corporation 2007
003-1735-00 Rev. FA1 5/9/17
Intended Use
This product is intended to control patient positioning
while providing better patient access by eliminating the
cord from the controllers.
Warranty
SCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants
to the original retail purchaser that it will, at Midmark’s option, repair or
replace components of the domestic and international medical products
manufactured by Midmark (except for components not warranted under
“Exclusions”) that are defective in material or workmanship under normal
use and service. The sole remedy under this limited warranty is the re-
pair or replacement, at Midmark’s option, of the applicable components.
This limited warranty shall only apply to defects that are reported to
Midmark within the applicable warranty period and which are determined
to exist upon examination by Midmark,. This warranty extends only
to the original retail purchaser of a product and is not transferable or
assignable. Replacement components or products may be used and/
or refurbished components or products, provided they are of like quality
and specications as new components or products.
Midmark warrants to the original retail purchaser that during the ap-
plicable warranty period it will repair or replace software contained within
the products manufactured by Midmark (except for those not warranted
under “Exclusions”) if: (1) the media on which the software is furnished
exhibits defects in material or workmanship under normal use; or (2) the
software does not substantially conform to its published specications.
APPLICABLE WARRANTY PERIOD The applicable warranty period,
measured from the date of invoice to the original retail purchaser of
the product and shall be one (1) year for all warranted products and
components.
OBTAINING WARRANTY SERVICE Warranty service must be obtained
through either Midmark or an authorized dealer in the Midmark product
line for which warranty service is requested. Midmark may be contacted
for warranty service inquiries or issues via email at www.midmark.com;
by phone at 1-800-MIDMARK or by mail to Midmark Corporation, 60
Vista Drive, Versailles, Ohio 45380. It is the retail purchasers obligation
to arrange for delivery of a product to Midmark or one of its authorized
dealers for warranty service, which delivery shall be at retail purchaser’s
expense. It is also the retail purchaser’s obligation to comply with the
warranty service instructions provided either by Midmark or its autho-
rized dealer. The retail purchaser must provide Midmark with completed
warranty registration information within thirty (30) days after purchase in
order to obtain the
benets of this limited warranty.
EXCLUSIONS: This limited warranty does not cover and Midmark shall
not be liable for the following:
(1) Defects, damage or other conditions caused, in whole or in part,
by misuse, abuse, negligence, alteration, accident, freight damage,
negligent storage, tampering or failure to seek and obtain repair or
replacement in a timely manner;
(2) Products which are not installed, used, and properly cleaned and
maintained as required or recommended in the Midmark “Installation”
and/or “Installation/Operation Manual” for the applicable product, includ-
ing the specied structural and operational environmental conditions and
electrical requirements;
(3) Products considered to be of a consumable or sterile nature;
(4) Accessories or parts not manufactured by Midmark;
(5) Charges by anyone for adjustments, repairs, replacement parts,
installation or other work performed upon or in connection with such
products which are not expressly authorized in writing in advance by
Midmark;
(6) Costs and expenses of routine maintenance and cleaning; and
(7) Representations and warranties made by any person or entity other
than Midmark.
(8) Matching of color, grain or texture except to commercially acceptable
standards;
(9) Changes in color caused by natural or articial light;
(10) Custom manufactured products;
(11) Alterations or modications to the product by any person or entity other
than Midmark; and
(12) Products that would otherwise by covered under this limited warranty,
but are acquired: (i) from a person or entity that is not Midmark or one of its
authorized dealers; or (ii) from a Midmark dealer that is not authorized to
sell the product at issue in the geographic territory where the purchaser is
located, or is not authorized to sell the product at issue within the medical
market.
SOFTWARE; WITH RESPECT TO SOFTWARE THAT IS A PRODUCT OR
COMPONENT THEREOF, MIDMARK DOES NOT WARRANT THAT THE
SOFTWARE: (1) IS ERROR FREE; (2) CAN BE USED WITHOUT PROB-
LEMS OR INTERRUPTIONS; OR (3) IS FREE FROM VULNERABILITY
TO INTRUSION OR ATTACK BY VIRUSES OR OTHER METHODS.
EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER
MIDMARK’S ONLY OBLIGATION UNDER THIS LIMITED WARRANTY IS
THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK
SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT,
SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL
DAMAGES OR DELAYS, INCLUDING, BUT NOT LIMITED TO, DAMAGES
FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, LOSS OF DATA,
DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRAC-
TOR WAGES, PAYMENTS AND BENEFITS. THIS DISCLAIMER SHALL
SURVIVE ANY FAILURE OR ASSERTED FAILURE OF THE ESSEN-
TIAL PURPOSE OF THIS LIMITED WARRANTY OR ITS REMEDIES
SPECIFIED HEREIN. WARRANTY DISCLAIMER THIS WARRANTY IS
MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED
WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF
DEFECTIVE PARTS.
STATUTE OF LIMITATIONS No action may be brought against Midmark for
breach of this limited warranty, an implied warranty, if any, or for any other
claim arising out of or relating to the products, more than ninety (90) days
following expiration of the limited warranty period.
NO AUTHORIZATION No person or rm is authorized to create or approve
for Midmark any other obligation or liability in connection with the products.
Attention: Wired Hand & Foot Controls
Wired hand & foot controls are shipped standard with
all models. A wired controller (either hand or foot) is
required to perform the Association Procedure.
This procedure may be required in the event of a
malfunction, do not discard the wired controllers.
(Refer to: Association Procedure in this User Guide)
Calling for Service
If service is required, contact your Midmark dealer.
To contact Midmark Medical Technical Support:
US 844-856-1230 / Canada 937-526-8585
Monday-Friday 8:00 am until 7:00 pm (EST)
Stop
Home
Specifications
Range of Operation ............. 20 ft. (6 m) radius
Batteries:
Hand Control ................................. AA (qty. 2)
Foot Control ..................................AA (qty. 2)
Troubleshooting
When any control button is pressed, that controller
sounds a single “beep”. (All functions operate)
Cause: Low battery
Solution: Replace batteries
When any control button is pressed,
nothing happens. (No “beeps”, no movement, etc.)
Cause: 1. Batteries completely dead
2. Wireless controller has lost
“association” to chair
Solution: 1. Replace batteries
2. Perform Association Procedure*
*The wireless controllers will only function with the
chair they have been “associated” with. This prevents
unwanted movement in locations with more than one
chair.
If further service is required,
contact your authorized Midmark dealer.
For Serial Numbers V1495519 thru Present
Association Procedure:
A. Disconnect power to the table for at least 3 seconds.
B*.
Reconnect power, wait for at least two seconds,
then press & hold the Stop & Home buttons on the
wireless controller until you hear three “beeps”.
C.
Check for proper operation of wireless controller.
D.
If associating a hand and foot control, repeat procedure
using the other wireless controller.
* Note: Step B must be performed within 10 seconds of the power up
beep sequence from the table.
IC Compliance Statement
Interference
“This device complies with Industry Canada license-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.”
“Le présent appareil est conforme aux CNR ďIndustrie Canada applicables aux
appareils radio exempts de licence. Ľexploitation est autorisée aux deux conditions
suivantes: (1) ľappareil ne doit pas produire de brouillage, et (2) ľutilisateur de
ľappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible ďen compromettre le fonctionnement.”
Antennas
“Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not
more than that necessary for successful communication.”
“Conformément à la réglementation ďIndustrie Canada, le présent émetteur radio peut
fonctionner avec une antenne ďun type et ďun gain maximal (ou inférieur) approuvé
pour ľémetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à ľintention des autres utilisateurs, il faut choisir le type ďantenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
ľintensité nécessaire à ľétablissement ďune communication satisfaisante.”
Home
Stop
For Serial Numbers V2200 thru V1495518
Association Procedure:
A. Using the wired hand or foot control, press & hold
the Stop & Home buttons simultaneously.
(after two seconds you will hear a single “beep”)
B*.
Using the wireless hand control, press & hold
the Stop & Home buttons until you hear three “beeps”.
(One long “beep” indicates the association failed. Unplug
unit for one minute and repeat Steps A & B.)
C.
Check for proper operation of wireless hand control.
D.
Repeat procedure for wireless foot control.
* Note: Step B must be performed within 3 seconds of Step A,
failure to do so will cause the procedure to fail.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.
Any modications to this product may violate the rules of the Federal Communications
Commission and make operation of the product unlawful.
Compliance Information
The wireless control’s “association” is preset at the factory.
This procedure is only required if there is a malfunction, or if you
are attempting to use the controller with a chair other than the one
it was originally associated with.
MA10329i
(Note: Battery access cover is located on back of controller)
  • Page 1 1
  • Page 2 2

Midmark 641 Power Procedures Chair Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues