Bodet Style 5S OP Manuel utilisateur

Catégorie
Horloges murales
Taper
Manuel utilisateur
1
Notice d’installation et de mise en service
Installation and operation manual
Style 5S Hôpital – IND IMP AFNOR
Style 5S Hospital – IND IMP AFNOR
Style 7S Hôpital - IND IMP AFNOR
Style 7S Hospital - IMP IND AFNOR
HORLOGE DIGITALE pour hôpital
DIGITAL CLOCK for hospitals
S’assurer à réception que le produit n’a pas été endommagé durant le transport pour réserve au transporteur.
When receiving goods, please check that the item is not broken. If the product is damaged, a claim
should be addressed to the shipping company.
Réf : 607795D
www.bodet-time.com
BODET Time & Sport
1, rue du Général de Gaulle
49340 TREMENTINES I France
Tél. support France: 02.41.71.72.99
Tel. support (intl): +33 241 71 72 33
2
EN
Table of contents
I – Initial checks 4
1.1 Unpacking the clock 4
1.2 Cleaning 4
II – Installation 5
2.1 Clock installation 5
2.2 Installing the keypad 8
2.3 Electrical connections for various synchronisation cards 8
III – Connecting to the time distribution network 9
3.1 Parallel distribution with inverted polarity 9
IV – Default configuration 9
V – Basic configuration 10
5.1 Setting time/date/year 10
5.2 Configuration menu 11
VI – Memory backup 12
VII – Technical specifications 12
VIII – Maintenance menu 13
8.1 AFNOR synchronisation 13
8.2 IMPULSE synchronisation 14
3
FR
Table des matières
I – Vérification initiale 15
1.1 Déballage de l’horloge 15
1.2 Nettoyage 15
II – Installation 16
2.1 Montage de l’horloge 16
2.2 Montage du pupitre 19
2.3 Branchements électriques des différentes cartes de synchronisation 19
III – Raccordement sur réseau de distribution horaire 20
3.1 Distribution parallèle à polariré inversées 20
IV – Configuration par défaut 20
V – Configuration 21
5.1 Réglage Heure/Date/Année 21
5.2 Menu configuration 22
VI – Sauvegarde mémoire 23
VII – Caractéristiques techniques 23
VIII – Menu technicien 24
8.1 Synchronisations AFNOR 24
8.2 Synchronisation IMPULSION 25
4
I Initial checks
Thank you for choosing a BODET clock.
This product has been carefully designed, adhering to ISO 9001 quality processes, to ensure your
satisfaction. We recommend that you read this manual and the general safety measures and
operating instructions carefully before handling the clock.
Retain this manual for reference for the lifespan of your clock.
The information supplied is non-binding; Bodet reserves the right to make changes to equipment,
including functional, technical and aesthetic changes or changes to colours, without notice.
Failure to observe these instructions may cause irreversible damage to the clock and
invalidate the warranty.
These instructions relate to synchronisation of the clocks as follows:
IND (independent) – IMP (impulse): The clock should be configured independently, or as part
of a time distribution network, driven by a master clock which sends out impulses (independent,
minute or half minute in parallel).
AFNOR: The clock should be installed as part of a wired coded time distribution network in
compliance with AFNOR or IRIG-B standards.
1.1 Unpacking the clock
Carefully unpack the clock and check the contents of the package. This should include:
Style 5S ou 7S Hospital clock
Anti-static cleaning kit
Manual
IMPORTANT: product identication label
An identification label is affixed to the back of the clock. Use the URL link shown to download these
instructions from the Bodet website: www.bodet-time.com.
1.2 Cleaning
Use an anti-static product identical to that in the cleaning kit provided.
Never use alcohol, acetone or other solvents which may damage your clock's casing or glass.
EN
5
II – Installation
2.1 Clock installation
2.1.1 Mounting without back cover
According to the model of the clock make the cut-out following the dimensions listed in table below:
Dimensions in mm
a) Insert the clock in the cut-out in order to mark the position of the 4 mounting screws.
b) Remove the clock and drill 4 holes Ø6 mm to insert the wall plugs.
c) Feed the power cable and the synchronisation cable throught the cut-out.
d) Connect the clock, adjust the brightness (refer to page 7) and set the time (refer to page 10).
e) Apply a silicone seal between the clock and the wall.
f) Fix the clock to the wall with the 4 screws Ø4 mm.
EN
A B C D E
Style 5S OP 46 400 366 68 109
Style 7S OP 440 406 85 125
Installation without the back cover
6
2.1.2 Mounting with back cover
According to the model of the clock make the cut-out following the dimensions listed in table below:
Dimensions in mm
a) Insert the back cover in the cut-out in order to mark the position of the 6 mounting screws.
b) Remove the back cover and drill 2 holes Ø 6 mm ( ) to insert the wall plugs for the back cover
mounting.
c) Drill 4 holes Ø10 mm ( ) to make room for the 4 clock mounting rivets.
d) Feed the power cable and the synchronisation cable throught the cut-out and cable glands of the
back cover.
e) Apply a silicone seal between the back cover (fixing brackets) and the wall.
f) Fix the back cover to the wall with the 2 screws Ø4 mm.
g) Connect the clock, adjust the brightness (page 7) and set the time (refer to page 10).
h) Apply a silicone seal between the back cover and the clock.
i) Fix the clock to the back cover with the 4 screws Ø4 mm.
EN
A B C D E
Style 5S OP 46 400 366 68 109
Style 7S OP 440 406 85 125
Installation with the back cover
Back cover mounting screws
Ø4 mm
X
Y
Y
X
Y
7
EN
2.1.3 Connections
- Connect the electronic board (see next page) and the keypad (optional) to the terminal strip on
the back of the clock.
- Set the brightness by pressing the "S" and "+" keys on the back of the clock (see above).
- Brightness may be adjusted when the Style clock is in normal use mode, i.e. in neither the
configuration menu, nor in the set time menu. The default brightness is level 3.
Example of a Style 5S Hospital
Impulse synchronisation electronic board
Connector for wiring
synchronisation via impulse
Configuration keys: S and +
Connecting the keypad
T-
T+
0V
15V
Brown
White
Green
Yellow
+Hold down for 3 seconds
+++
S
End of menu
Select light intensity:
LUM 1: low intensity
LUM 4: high intensity
8
EN
2.2 Installing the keypad
To install and use the keypad (including in timer mode), refer to the instructions supplied with the
keypad.
2.3 Electrical connections for various synchronisation cards
Below are the wiring diagrams for the electronic boards for the various synchronisations.
IND (independent) synchronisation card
IMP (impulse) synchronisation card
AFNOR synchronisation card
Connector for control keypad
Refer to the keypad instructions
(supplied with the keypad)
Neutral (blue)
Phase (brown)
Use the
appropriate
polarity for
the network
(otherwise
there will be
a delay of
30-60 secs).
Neutral (blue)
(black)
(red)
Phase (brown)
Connector for control keypad
Refer to the keypad instructions
(supplied with the keypad)
Polarity is
irrelevant to
the network
Neutral (blue) (black)
(red)
Phase (brown)
Connector for control keypad
Refer to the keypad instructions
(supplied with the keypad)
9
EN
III – Connecting to the time distribution network
Connect the 100-240VAC 50/60Hz mains power supply. (See page 8)
3.1 Parallel distribution with inverted polarity
Minute // (12-24-48 Volt), ½ minute // (24 Volt) and AFNOR
1) Ensure that the clock is designed to be synchronised by "Impulse" or to be connected to a time
code distribution network that meets the AFNOR standard .
2) Connect the impulse cable to terminal strip (A). Use the correct polarity for impulse synchronisation.
There is no polarity in AFNOR.
Minute or ½ minute mode (only)
3) Select the impulse frequency (minute or ½ minute) (refer to page 14) and display mode
(refer to page 11).
4) Set the clock to the correct time (refer to page 10).
IV – Default configuration
Restore factory settings by keeping the red button on the electronic board pressed until the clock
turns black.
Location of button on the electronic board (example shows an Impulse card):
A
IMPULSE
AFNOR
OR
A
10
EN
V – Basic configuration
5.1 Setting time/date/year
To set time, date and year, press and hold "S" for 3 seconds.
+
+
+
+
+ +
+
+
+
+
Set hour
Set minutes
Set year
Set month
Set day
End of menu
S
SHold down for 3 seconds
S
S
S
S
11
EN
5.2 Configuration menu
Access the configuration menu by pressing and holding "S" then "+" for 3 seconds.
+
+
+
+
+
+ +
S
S
S
S
S
S
S
S
S
Select display mode: 12 or 24 hr (default 24 hr)
Hold down for 3 seconds
+
Show display options
(default HH:MM)
Select time zone
(default Eur)
Time difference:
hours (GMT mode)
Time difference:
minutes
(GMT mode)
Select day of the week (from 1 to 7)
Select a set date (from 1 to 30)
Month for changeover to summer time
(default 3, i.e. March)
Select week number for the
changeover to summer time
(from 1 to 7; F to configure a set date)
If 1 to 7
selected
If F selected
End of menu (GMT mode)
Local mode only for AFNOR synchronisation
Select energy-saving mode
(default nor)
Eco mode:
Select looped switch-off time from 0 to 23 (default: 23)
Select looped switch-on time from 0 to 23 (default: 6)
+
S
S
S
S
S
+
S
+
+
+ + +
+ + +
+ +
++++
Time difference: hours (PrG mode)
Time difference: minutes (PrG mode)
S
S
+ + +
+
+ + +
+ + +
+ +
S
+
+
Month for changeover to winter time
(default 10, i.e. October)
+
+
Select week number for the
changeover to winter time
(from 1 to 7; F to configure a set date)
If 1 to 7
selected
If F selected
S
S
Select day of the week (from 1 to 7)
Select a set date (from 1 to 30)
End of menu
+ +
+ +
12
EN
VI – Memory backup
Style clocks have a permanent backup feature that is used to store all of the configuration parameters
and the display settings, even in the event of a prolonged power cut.
VII – Technical specifications
Style clocks comply with LVD 2014/35/EU and EMC 2014/30/EU directives.
– Power supply: 100-240VAC, 50/60Hz (depending on model).
– Max. consumption: 100-240VAC; 75-50 mA.
– In the event of a power failure, time and date are saved for 1 week.
– Time base backup:
Independent clock: 15 days in the event of a power cut.
Other synchronisations: no backup feature; at each reboot, the clock waits for a synchronisation
signal.
– Time accuracy: 0.2 sec./day
– Operating temperature: -5° to +55°C.
– Protection rating: IP65, IK07 (Style 7S OP), IK09 (Style 5S OP).
460
45
440
85
117.5
147
398
1.5
Style 5S OP
Style 7S OP
400
360
41 420
68
130
101
2
13
EN
VIII – Maintenance menu
To access the maintenance menu, open the configuration menu by pressing and holding "S",
then "+" for 3 seconds. Release both keys, then press and hold "S", then "+" again for 7 seconds.
8.1 AFNOR synchronisation
+
S
S
S
S
S
S
S
S
Hold down for 3 seconds
+
+
SHold down for 7 seconds
+
Open configuration menu
Software version
May differ from the version shown depending on the date of purchase.
Select synchronisation mode
AFn: AFNOR (default)
AFnI: Independent AFNOR (the clock operates using its internal time base)
IrIG: IRIG-B
Reset clock (enabled if “rstY” is selected)
Restore factory settings (enabled if “dF Y” is selected)
Display test (tests for correct functioning of all LEDs)
End of menu
+
+
+Select mode: cod or loc (default cod)
Cod: the clock displays the time code data received, without modification.
Loc: the clock calculates and displays local time using the time code data received
plus its summer/winter time changeover and time difference settings.
S
+
+
+
Select time zone
(default Eur)
+
+ + +
++++
14
EN
8.2 IMPULSE synchronisation
+
S
S
S
Hold down for 3 seconds
+
+
SHold down for 7 seconds
+
Open configuration menu
Software version
May differ from the version shown depending on the date of purchase.
Select synchronisation mode
Min: minute impulse (default)
1:2M: ½ minute impulse
S
S
S
Reset clock (enabled if “rstY” is selected)
Restore factory settings (enabled if “dF Y” is selected)
Display test (tests for correct functioning of all LEDs)
End of menu
+
+
+
15
I – Vérification initiale
Nous vous remercions d’avoir choisi une horloge BODET.
Ce produit a été conçu avec soin pour votre satisfaction d’après les bases qualité ISO9001.
Nous vous recommandons, de lire attentivement ce manuel ainsi que les consignes générales
de sécurité et précautions d’utilisation avant de commencer à manipuler l’horloge.
Conserver ce manuel pendant toute la durée de vie de votre horloge afin de pouvoir vous y reporter
à chaque fois que cela sera nécessaire.
Données non contractuelles. Bodet se réserve le droit d’apporter aux appareils certaines modifications
fonctionnelles, techniques, esthétiques, ou de couleurs, sans préavis.
Tout usage non conforme à la présente notice peut causer des dommages irréversibles sur
l’horloge, et entraîne l’annulation de la garantie.
La présente notice concerne les synchronisations d’horloges suivantes:
IND (indépendante) – IMP (impulsions): L’horloge peut être configurée en indépendante,
ou être intégrée à un réseau de distribution horaire piloté par une horloge mère délivrant des
impulsions (Indépendante, minute ou 1/2 minute sur ligne parallèle).
AFNOR: L’horloge doit être intégrée à un réseau de distribution horaire temps codé conforme
à la norme AFNOR ou à l’IRIG-B.
1.1 Déballage de l’horloge
Déballer soigneusement l’horloge et vérifier le contenu de l’emballage. Celui-ci doit comprendre :
L’horloge Style 5S ou 7S Hôpital,
Une pochette de nettoyage antistatique,
Ce manuel.
IMPORTANT : marquage étiquette produit.
Une étiquette signalétique, apposée au dos de l’horloge est visible. Elle indique un lien URL
permettant de télécharger cette notice depuis le site internet www.bodet-time.com.
1.2 Nettoyage
Utiliser un produit antistatique identique à celui de la pochette de nettoyage fournie.
Ne jamais utiliser d’alcool, d’acétone ou autres solvants susceptibles d’endommager l’horloge.
FR
16
2.1 Montage de l’horloge
2.1.1 Montage sans fond d’encastrement
Selon le modèle de l’horloge, faire un découpe en suivant les dimensions listées dans le
tableau ci-dessous:
Dimensions en mm
a) Présenter l’horloge de manière à marquer l’emplacement des 4 trous de fixation.
b) Retirer l’horloge et percer les 4 trous Ø6 mm pour y insérer les chevilles.
c) Passer les câbles d’alimentation et de synchronisation à travers la découpe.
d) Raccorder l’horloge, régler la luminosité (page 18) et effectuer la mise à l’heure (page 21).
e) Déposer un joint silicone entre l’horloge et le mur.
f) Fixer l’horloge au mur avec les 4 vis Ø4 mm.
II – Installation mécanique
FR
A B C D E
Style 5S OP 46 400 366 68 109
Style 7S OP 440 406 85 125
Intallation sans fond d’encastrement
17
2.1.2 Montage avec fond d’encastrement
Selon le modèle de l’horloge, faire un découpe en suivant les dimensions listées dans le
tableau ci-dessous:
Dimensions en mm
a) Présenter le fond d’encastrement de manière à marquer l’emplacement des 6 trous de fixation.
b) Retirer le fond d’encastrement puis percer 2 trous ( ) au Ø6 mm pour l’insertion des chevilles
de fixation pour le montage de ce dernier.
c) Percer les 4 trous ( ) au Ø10 mm pour permettre le passage des 4 rivets de fixation de
l’horloge.
d) Passer les câbles d’alimentation et de synchronisation à travers la découpe et les presse-
étoupes du fond d’encastrement.
e) Déposer un joint silicone entre le fond d’encastrement (oreilles de fixation) et le mur.
f) Fixer le fond d’encastrement au mur avec les 2 vis de Ø4 mm.
g ) Raccorder l’horloge, règler la luminosité (page 18) et effectuer la mise à l’heure (page 21).
h) Déposer un joint silicone entre le fond d’encastrement et l’horloge.
i) Fixer l’horloge au fond d’encastrement avec les 4 vis Ø4 mm.
A B C D E
Style 5S OP 46 400 366 68 109
Style 7S OP 440 406 85 125
Intallation avec fond d’encastrement
Vis de xation Ø4mm du fond
d’encastrement
X
Y
Y
X
Y
FR
18
Exemple d’une Style 5S Hôpital
Carte électronique de synchronisation par impulsions
Connecteur pour câblage en
synchronisation par impulsions
Touches de configuration: S et +
Câblage du pupitre
T-
T+
0V
15V
Marron
Blanc
Vert
Jaune
+Maintenir l’appui pendant 3 secondes
+++
S
Fin du menu
Choix de l’intensité:
LUM 1 : intensité faible
LUM 4 : intensité forte
FR
2.1.3 Connexions
Câbler la carte électronique (Cf. page suivante) et le pupitre de commande (en option) sur le bornier
de la carte électronique au dos de l’horloge.
Régler la luminosité: ce réglage s’effectue en appuyant sur les touches capacitives «S» et «+» au
dos de l’horloge (Cf. ci-dessus).
Le réglage de luminosité peut être effectué lorsque l’horloge Style est en mode d’utilisation normale,
c’est-à-dire lorsqu’elle ne se trouve ni dans le menu de configuration, ni dans le menu de mise
à l’heure. Niveau de luminosité par défaut : 3.
19
2.2 Montage du pupitre
Pour l’installation et l’utilisation (y compris en mode chronomètre) du pupitre, se reporter à la
notice livrée avec ce dernier.
2.3 Branchements électriques des différentes cartes de synchronisation
Ci-dessous, les schémas de câblage en fonction des cartes électroniques pour les différentes
synchronisations.
Carte de synchronisation IND (indépendante)
Carte de synchronisation IMP (impulsions)
Carte de synchronisation AFNOR
FR
Câblage du pupitre de commande
Se reporter à la notice du pupitre
(livrée avec ce dernier)
Neutre (bleu)
Phase (marron)
Câblage du pupitre de commande
Se reporter à la notice du pupitre
(livrée avec ce dernier)
Respecter la
polarité par rapport
au réseau (en cas
contraire, décallage
de 1/2 minute ou 1
minute).
Neutre (bleu)
(rouge)
(noir)
Phase (marron)
La polarité sur le
réseau n’a pas
d’importance
Neutre (bleu) (noir)
(rouge)
Phase (marron)
Câblage du pupitre de commande
Se reporter à la notice du pupitre
(livrée avec ce dernier)
20
III – Raccordement sur réseau de distribution horaire
Brancher l’alimentation secteur 100-240VAC 50/60Hz. (Cf. page précédente).
3.1 Distribution parallèle à polariré inversées
Minute // (12-24-48 Volt), 1/2 Minute // (24 Volt) et AFNOR
1) Vérifier que l’horloge est bien synchronisée par “Impulsion” ou qu’elle peut être intégrée à un
réseau de distribution horaire temps codé conforme à la norme AFNOR.
2) Raccorder la ligne d’impulsions au bornier (A) en respectant la polarité pour la synchronisation
par impulsions. Il n’y a pas de polarité en AFNOR.
Mode Minute ou 1/2 Minute (uniquement):
3) Sélectionner la fréquence d’impulsions (minute ou 1/2 minute) (se reporter page 25) et le mode
d’affichage (se reporter page 22).
4) Mettre l’horloge à l’heure (se reporter page 21).
IV – Configuration par défaut
Le retour de la configuration usine s’effectue en appuyant, jusqu’à la mise au noir de l’horloge, sur
le bouton poussoir (rouge) de la carte électronique.
Localisation du bouton poussoir sur la carte électronique (exemple d’une carte Impulsion):
FR
A
IMPULSION
AFNOR
OU
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Bodet Style 5S OP Manuel utilisateur

Catégorie
Horloges murales
Taper
Manuel utilisateur

dans d''autres langues