Eaton CGLine+ Web Compact Controller Manuel utilisateur

Taper
Manuel utilisateur
CGLine+ Web Controller
CGLine+ Web Compact Controller
Target group: Skilled electricians
Zielgruppe: Elektrofachkraft
Public cible : Électriciens conrmés
Quick Installation Manual /Kurzanleitung / Guide d’installation rapide
ZNO2050500 C 05/2021
2Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Description /
application area
This short instruction manual describes
only a quick commissioning procedure of
the CGLine+ Web Compact Controller. A
complete Installation and Operating
Safety notes
CAUTION
The CGLine+ Web Compact Controller
interface must be
operated in an undamaged ad functional
state.
This equipment is intended for use in
restricted area, and must be installed
within 2 meters high, in the restricted
area that only qualified people can
access. This equipment is not suitable for
use in locations where children are likely
to be present.
When carrying out maintenance work to
the device the device must be switched
off. When carrying out device main-
tenance, observe national safety and
accident prevention regulations and the
safety notes in the operating instructions
below designated with .
Only skilled person is allowed to change
a component providing a safeguard
function.
Before removing CGLine+ Web Compact
Controller for maintenance, replacement
and/or repair all power should be
disconnected.
An appropriate disconnect device shall
be provided as part of the building instal-
lation .
CGline+ Web Compact Controller must
be earthed.
CYBERSECURITY
This chapter provides guidelines to securely
deploy the CGLine+ Web Compact Controller
and minimize the cybersecurity risk to the
installer system.
Asset identification and inventory:
Ensure that the CGLine+ Web Compact
Controller is labelled and inventoried
using the Part number and MAC address
printed on the product label, the IP
address configured during the installa-
tion of the material and actual firmware
version.
Restrict Physical access: Ensure that
physical access to the CGLine+ Web
Compact Controller is restricted only
to authorized user(s). CGLine+ Web
Compact Controller
supports the physical access ports RJ-45,
USB that can be used to tamper the
device. Access to these ports should be
restricted to authorized personnel only.
Secure the facility and equipment rooms
or closets with access control mecha-
nisms such as locks, entry card readers,
guards, man traps, CCTV, etc. as appro-
priate. Monitor and log the access at all
times. Before connecting any portable
device through a USB port or SD card
slot, scan the device to prevent unau-
thorized access.
Restrict Logical access: Access to Admin
& ‘Service user accounts should be
GB
Compliant with:
Audio,video,information and communica-
tion technology equipment-part 1:safety
requirement : EN62368-1
Lamp controlgear-General and Safety
requirement- EN61347-1
Developed, manufactured and tested ac-
cording to DIN EN ISO 9001.
Instuction are downloadable from the web-
site of the CGLine+ Web Compact Controller.
Commissioning and
modifying network settings
Please connect a patch cable with RJ45 plugs
between the Compact Controller and a PC
(e.g. notebook).
3
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
restricted to authorized person-
nel only as system configuration
can be tampered by abusing these
accounts. Ensure password length,
complexity and expiration require-
ments are appropriately set, particu-
larly for all administrative accounts
(e.g., minimum 10 characters, mix of
upper- and lower-case and special
characters, and expire every 90 days,
or otherwise in accordance with
your organizations policies).
Restrict Network Access: Ideally,
CGLine+ Web Compact Controller
should be installed on a segre-
gated network. However, when the
CGLine+ Web Compact Controller
is connected to a wider network,
make sure that the IP address and
MAC address are filtered at the
router side, or using a firewall. In
addition to this, open only the ports
used by the CGLine+ Web Compact
Controller (SMTP as configured, 587
for SMTPS, 443 for HTTPS, and 5050
for OPC communication).
Logging and event management:
Make sure you log all relevant
system and application events,
including all administrative and
maintenance activities. Logs should
be protected from tampering and
other risks to their integrity (for
example, by restricting permissions
to access and modify logs, transmit-
ting logs to a security information
and event management system,
etc.). Ensure that logs are retained
for a reasonable and appropriate
length of time. Review the logs regu-
larly. The frequency of review should
be reasonable, taking into account
the sensitivity and criticality of the
CGLine+ Web Compact Controller
and any data it processes. The details
how to export the logs are defined
in chapter 7.14.
Secure maintenance: In case the
firmware of the device needs to be
updated, you will be contacted by
your Eaton local support.
Malware Defenses: Eaton recom-
mends deploying adequate mal-
ware defenses to protect the prod-
uct or the platforms used to run the
Eaton product.
Business continuity / cybersecurity
disaster recovery: Eaton recom-
mends incorporating CGLine+
Web Compact Controller into the
organizations business continu-
ity and disaster recovery plans.
Organizations should establish
a Business Continuity Plan and a
Disaster Recovery Plan and should
periodically review and, where pos-
sible, exercise these plans. As part
of the plan, important device data
should be backed up and securely
stored, including the current con-
figuration and documentation of the
current permissions / access con-
trols, if not backed up as part of the
configuration. The CGLine+ PC can
be used to save the configuration of
a CGLine+ Web Compact Controller
using the save file button in the
main page.
Decommissioning: It is a best prac-
tice to purge data before dispos-
ing of any device containing data.
Guidelines for decommissioning
are provided in NIST SP 800-88.
To ensure data is unrecoverable,
CGLine+ Web Compact Controller
must be securely destroyed. Method
of destruction include disintegra-
tion, Incineration, Pulverization, or
Melting of the electronic inside the
CGLine+ Web Compact Controller.
More information related to
cybersecurity best practices is avail-
able on SD card provided with the
device.
A copy of End user license agree-
ment is available on the SD card
provided with the device. By
agreeing to continued use the
product, terms and conditions of
EULA are applicable.
4Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
1. PANEL DESCRIPTION
Left / Back Validate / Select
Cancel / Back
Home
Log out + reactivate the
screen in save mode
Log out + switch off
the screen
Multi-tap keypad
(0: Special characters
#: Uppercase / Lower case)
Switch on/off
the screen
Activate USB
(hold for 3s.)
Green : OK
Blinking : Test
Red : Failure
Right / Validate
Up
Down
Unused
1.1. Front panel
5
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
USB cable A-B (option)
230V/AC
2. NETWORK SETTINGS
L/N/
230V 50/60Hz LAN (RJ45) with LED displays:
Yellow = Link
Green = Traffic
In1/In2 = 2x digital inputs
S1/S2 = Block input
11, 12, 14, 21, 22, 24
= 2x relay outputs
Connection CGLine+
bus line D1-D2
To avoid any risk of ignition, mains conductors must be sufficiently tightened in the terminal (torque min. 40cNm).
1.2. Electrical connections
2 USB Ports
To ensure electrical safety, cables must be tied together with the cable ties
supplied with the product.
Comm.
230V 50/60Hz
6Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
The CGLine+ Web Compact controller is supplied as standard with the fixed IP address
192.168.1.200.
Operation via dhcp (dynamic IP address assignment) is possible but not factory-activated.
Because typical company networks only permit own-assigned IP addresses, we recommend
configuring network settings via direct connection to a PC, e.g. a notebook.
The network configuration can be done directly on the CGLine+ Web Compact con-
troller. The connection to a PC via a patch cable is optional.
The devices must be in the same subnet, meaning the network card of the PC must be set
to 192.168.1.xxx (not equal to 200), e.g. 192.168.1.50 (subnet to 255.255.255.0).
Settings for gateway and DNS must not be taken into account with a direct connection.
3. FIRST START
a
CGLine+ Compact
CGLine+ Compact
1.User
Select User for choosing a new
password. Enter the password
by default "GUEST", and enter
a new password (6
characters minimum).
Then validate with Save.
230V/AC
CGLine+ Compact
2.Administrator
Go back to previous display.
Select Admin for choosing a
new password.Enter the pass-
word by default "EATON" and
enter a new password (6
characters minimum).
Then validate with Save.
The CGLine Web Compact Controller is now ready to be used !
b
c
11:40
Z1
CGLine+ Compact
Login
Line 1
Line 2
Z2 Z3 Z4
Operation
Blocked
Failure Test
No luminaire
d
When the CGLine+ Web
Compact Controller starts, a
loading page appears during
3 seconds.
Then, a recap of the entire installation appears on screen. You can detect easily a failure
and identify the line and zone in which the problem is.
Passwords for User and Admin must be changed during the first connection. Select
Administrator and enter the password by default "EATON".
11:40 Admin
21/01/2020
Old password
Save
New password
Confirm password
11:40 User
21/01/2020
Old password
Save
New password
Confirm password
7
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
4. GENERAL CONFIGURATION
aLogin as Admin, with the
password you previously chose.
Then select Commands in the
general menu.
11:40
Admin
21/01/2020
4.Commands
11:40
Login : Admin
Password
21/01/2020
OkCancel
X
a
b
4.1. Language setting
Login as Admin, with the
password you previously chose.
Then select Configuration in
the main menu.
11:40
Login : Admin
Password
21/01/2020
OkCancel
X
11:40
Admin
21/01/2020
3.Configuration
11:40
Admin
21/01/2020
>Configuration
1.General
2.Test
3.Input
4.Output
5.Network
6.Email
7.Address
Select
11:40
Admin
21/01/2020
>Configuration->General
1.Name
2.Password change
3.Time
4.Date
5.Language
Select
11:40
Admin
21/01/2020
>Configuration->General->Language
1.English
2.Français
3.Deutsch
4.Italian
5.Portuguese
6.Nederlands
Save
c
Select General and then
choose Language in the next
menu.
Select the language you need,
and then select Save for saving
your choice.
4.3. Initialisation of luminaires
4.2. Date and time setting
Stay in the General menu, and
select Time for updating the
time, and Date for updating
the date.
Select Save for saving the
updates.
11:40
Admin
21/01/2020
Controller date (dd/mm/yyyy)
Save
21/01/2020
Cancel
X
11:40
Admin
21/01/2020
Controller time (hh:mm)
Save
11:40
Cancel
X
8Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
bEnter Initialisation commands,
and then choose All lines.
11:40
Admin
21/01/2020
>Commands
1.Addressed commands
2.Initialisation commands
3.Adaptive Evacuation
Select
11:40
Admin
21/01/2020
>Initialisation commands
1.All lines
2.Line 1 ( 5 Luminaire)
3.Line 2 (0 Luminaire)
Select
c
11:40
Admin
21/01/2020
>All lines
1.Search all lamp
2.Search new lamp
3.Load config PCSoft
Select
11:40
Admin
21/01/2020
Operation in course
Line_1 : 5 Line_2 : 0
Select Search all lamp, and wait
for the complete loading.
Check the number of lamps, and
click on .
dOPTIONAL : You can change the
dates of automatic tests.
Go back to main menu, and
select Configuration.
Then select Test .
11:40
Admin
21/01/2020
3.Configuration
11:40
Admin
21/01/2020
>Configuration
1.General
2.Test
3.Input
4.Output
5.Network
6.Email
7.Address
Select
Select the test group you want
to update.
Choose the type of test, and
configure the new test time.
11:40
Admin
21/01/2020
>Configuration->Test group 1
1.Function test
2.Duration test
Select
11:40
Admin
21/01/2020
>Next functional test
1.Time : 18:00
2.Date : 01/01/2099
3.Test period : 07 days
4.Save
Select
Once the test features are
updated, select Save.
11:40
Admin
21/01/2020
>Next functional test
1.Time : 18:00
2.Date : 01/01/2099
3.Test period : 07 days
4.Save
Select
Conguration Saved
eThe CGLine+ Web Compact Controller is configured with basic settings. For all
configuration details, please see refer to CGLine+ Web Compact Controller user
manual.
If one or more luminaires are
missing, please refer to complete
user manual.
Mark the entry Internet protocol
version 4 1, then continue with
“Properties” 2.
9
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
5. PC NETWORK CARD SETTING
1
2
Mark the entry Internet protocol
version 4 1, then continue with
“Properties” 2.
PC network card setting:
To modify the network settings of the PC open the system control
Network and release centre
Modify adapter settings
Right mouse click on “LAN connection”
Properties.
The following screen is displayed:
10 Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Usually the network card is on DHCP, i.e. Automatically reference IP address”.
Modify the entry to “Use the following IP address and specify the following
values for the IP address and the subnet mask (displayed automatically):
IP address: 192.168.1.50
Subnet mask: 255.255.255.0
Clicking on OK assumes the settings so that the web page of the CGLine+ Web Compact
Controller can now be opened via any web browser, e.g. Firefox. Open a web browser and
enter the IP address “https://192.168.1.200” into the address bar.
The network card modifications should be reset following configuration of the network set-
tings of the web controller.
The start screen of the CGLine+ web controller now opens.
1
A login 1 is necessary. Two accounts are available:
1. User: Admin Password: Enter the password you chose for Admin
2. User: User Password: Enter the password you chose for User
To modify the network settings, please login as Admin.
CGLine+ Compact
2.Administrator
11
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Before accessing the webserver, two security pages are displayed on the browser by
security protocols.
The following web pages appear:
Click on Continue to this website on the first page.
Click on Advanced on the second page, and then on Add Exception.
IMPORTANT
A certificate error message can be displayed during the first connection to the controller
website.
Confirm by clicking on Continue to reach the login page. For installing the certificate, click
on CA certificate on the left.
The certificate can now be imported via your browser. The steps to follow can be different
according the browser you use (watch tutorial videos on videos.eaton.com).
The function of the website is also given without certificate, but it will alway require the
confirmation of this security notice.
12 Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
To change the network settings to desired IP-settings, click to the menu Configuration 1,
register Network 2:
1
2
After configuration of the IP-settings, the new configuration will overtake via the button
Save.
The controller is now reachable under the new IP-settings.
To download the complete instruction manual click on the download button Manual. The
complete manual can be saved as .pdf-file on a desired destination. To open the manual an
Acrobat Reader is required.
After logging in, the submenus appear:
CGLine+ Compact Controller
1
It is recommended to change the passwords after commissioning. For this,
download the complete manual 1. It is described in chapter 7.11.
13
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Sicherheitshinweise
ACHTUNG
Der CGLine+ Web Compact Controller ist
bestimmungsgemäß in unbeschädigtem
und einwandfreiem Zustand zu betrei-
ben.
Der CGLine+ Web Compact Controller ist
für den Einsatz in Bereichen vorgesehen,
in dem nur qualifizierte Personen Zugang
haben. Das Gerät muss innerhalb einer
Höhe von zwei Metern installiert werden.
Dieses Gerät ist nicht für die Verwendung
an Orten geeignet, an denen sich Kinder
Zugriff verschaffen könnten.
Bei Durchführung von Arbeiten am Gerät
ist sicherzu stellen, dass das Gerät span-
nungsfrei geschaltet ist!
Beachten Sie bei allen Arbeiten an dem
Gerät die nati onalen Sicherheits- und
Unfallverhütungsvorschriften und die
nachfolgenden Sicherheitshinweise in
der Betriebsanleitung, die mit einem
versehen sind.
Der Austausch eines Bauteils mit
Schutzfunktion darf nur durch eine
autorisierte und ausgebildete Fachkraft
erfolgen.
Eine geeignete Abschaltvorrichtung muss
als Teil der Gebäudeinstallation vorhan-
den sein .
CGline + Web Compact Controller muss
geerdet sein.
CYBERSECURITY
Dieses Kapitel enthält Richtlinien für die
sichere Bereit stellung des CGLine+ Web
Compact Controller und minimiert das Cyber-
Sicherheitsrisiko für das Installationssystem.
Identifizierung und Inventarisierung
von Vermögenswerten: Stellen Sie sicher,
dass der CGLine+ Web-Controller mit der
auf dem Produktetikett aufgedruckten
Teilenummer und MAC-Adresse sowie
der bei der Installation des Materials kon-
figurierten IP-Adresse und der aktuellen
Firmware-Version geken nzeichnet und
inventarisiert wird.
Beschränken Sie den physischen Zugriff:
Stellen Sie sicher, dass der physische Zugriff
auf den CGLine+ Web-Controller nur auf
autorisierte(n) Benutzer beschränkt ist.
Der CGLine+ Web-Controller unterstützt
die physischen Zugangsports RJ-45, USB,
mit denen das Gerät manipuliert werden
kann. Der Zugang zu die sen Ports sollte
auf autorisiertes Personal beschränkt sein.
Sichern Sie die Räumlichkeiten und Geräte
mit Zugangskontrollmechanismen wie
Schlössern, Zutrittskartenlesern, Wachen,
Personenschleusen, Überwachungskameras
usw., falls erforderlich. Überwachen und
protokollieren Sie den Zugriff jeder zeit.
Bevor Sie ein tragbares Gerät über einen
USB-Anschluss oder SD-Kartenschlitz
anschließen, scannen Sie das Gerät, um
unbefugten Zugriff zu verhindern.
Beschränken Sie den logischen Zugriff:
Der Zugriff auf die Benutzerkonten
Konform mit:
Einrichtungen für Audio/Video-,
Informations- und Kommunikationstechnik -
Teil 1: Sicherheitsanforderungen : EN62368-1
Geräte für Lampen - Teil 1: Allgemeine und
Sicherheitsanforderungen : EN61347-1
Netzwerkzugriff einschränken: Im Idealfall
sollte der CGLine+ Web-Controller in einem
separaten Netzwerk installiert werden. Wenn
der CGLine+ Web-Controller jedoch mit einem
breiteren Netzwerk verbunden ist, stellen Sie
sicher, dass die IP-Adresse und MAC-Adresse
auf der Routerseite oder über eine Firewall
gefiltert sind. Öffnen Sie außerdem nur die
vom CGLine+ Web-Controller verwende-
ten Ports (SMTP wie konfiguriert, 587 für
SMTPS, 443 für HTTPS und 5050 für OPC-
Kommunikation).
DE
14 Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Protokollierung und
Ereignismanagement: Stellen Sie
sicher, dass Sie alle relevanten System-
und Anwendungsereignisse protokol-
lieren, einschließlich aller Verwaltungs-
und Wartungsaktivitäten. Protokolle
sollten vor Manipulationen und anderen
Risiken für ihre Sicherheit geschützt
werden (z.B. durch Einschränkung
der Zugriffs- und Änderungsrechte,
Übertragung von Protokollen an
ein Sicherheitsinformations- und
Ereignisverwaltungssystem usw.).
Stellen Sie sicher, dass die Protokolle
für eine angemessene Zeit aufbewahrt
werden. Überprüfen Sie die Protokolle
regelmäßig. Die Häufigkeit der
Überprüfung sollte angemessen sein,
wobei die Sensibilität und Kritikalität
des CGline+ Web Compact Controller
und der von ihm verar beiteten Daten
berücksichtigt werden sollte. Die
Details zum Export der Protokolle sind
in Kapitel 8.15 beschrieben.
Sichere Wartung: Falls die Firmware
des Geräts aktu alisiert werden muss,
werden Sie von Ihrem lokalen Eaton-
Support kontaktiert.
Malware-Schutz: Eaton empfiehlt den
Einsatz von adäquate Malware zum
Schutz des Produkts oder des Systems,
mit dem das Eaton-Produkt verbunden
ist.
Business Continuity /
Cybersicherheit Disaster Recovery:
Eaton empfiehlt die Integration von
CGLine+ Web-Controllern in die
Business Continuity und Disaster
Recovery Pläne des Unternehmens.
Unternehmen sollten einen Business
Continuity Plan und einen Disaster
Recovery Plan erstellen und diese
Pläne regelmäßig überprüfen und,
wenn möglich, anwenden. Im Rahmen
des Plans sollten wichtige Gerätedaten
gesichert und sicher gespeichert
werden, einschließlich der aktuellen
Konfiguration und Dokumentation
der aktuellen Berechtigungen /
Zugriffskontrollen, falls nicht im
Rahmen der Konfiguration gesichert.
Mit dem CGLine+ PC kann die
Konfiguration eines CGLine+ Web-
Controllers über den Button “Datei
speichern” auf der Hauptseite ges-
peichert werden.
Außerbetriebnahme: Es ist eine
bewährte Vorgehensweise, Daten zu
bereinigen, bevor Sie ein Gerät mit
Daten entsorgen. Richtlinien für die
Stilllegung sind in NIST SP 800-88
enthalten. Um sicherzustellen, dass
Daten nicht wiederhergestellt werden
nnen, muss der CGLine+ Web-
Controller sicher zerstört werden. Zu
den Zerstörungsmethoden geren
Desintegration, Verbrennung,
Pulverisierung oder Schmelzen der
Elektronik im Inneren des CGLine+
Web Compact Controllers.
Weitere Informationen zur Cybersicherheit sind
auf der mit dem Gerät gelieferten SD-Karte
verfügbar.
Eine Kopie der Endbenutzer-Lizenzvereinbarung
befindet sich auf der SD-Karte, die mit dem
Gerät geliefert wurde. Durch die
Zustimmung bezüglich der weiteren Verwendung
des Produkts gelten die Bedingungen der EULA.
15
Quick installation manual CGLine+ Web Compact Controller ZNO2050500 C 05/2021 www.eaton.com
1. LED ANZEIGE UND TASTATUR
Links / Zurück
Bestätigen / Auswählen
Abbrechen / Zurück
Startbildschirm
Abmelden & Aktivierung
vom Bildschirm im
Speichermodus
Abmelden & Bildschirm
ausschalten
Tastatur
(0: Sonderzeichen
#: Groß- / Kleinbuchstaben)
Anzeige ein- oder
ausschalten
Activate USB
(3 sek. gedrückt halten)
Grün : OK
Blinken : Test
Rot : Fehlermeldung
Rechts / Bestätigen
Hoch
Runter
Keine Funktionalität
1.1. Frontansicht
16 Kurzanleitung Compact Controller ZNO2050500 C 05/2021 www.eaton.com
USB-Kebel A-B (option)
230V/AC
2. NETZWERKEINSTELLUNGEN
1.2. Elektrische Anschlüsse
2 USB Ports
L/N/
230V 50/60Hz
LAN (RJ45) mit LED-Anzeige
Gelb = verbunden (Link)
Grün = Datenverkehr (Traffic)
In1/In2 = 2xdigitale Eingänge
S1/S2 = Blockiereingang
11, 12, 14, 21, 22, 24
= 2x Relaisausgänge
Anschlüsse für den
CGLine+ Bus Strang 1
und 2
Um jegliche Zündgefahr zu vermeiden, müssen die Netzleiter in den Klemmen ausreichend fest angezogen werden
(Drehmoment min. 40 cNm).
Um die elektrische Sicherheit zu gewährleisten, müssen die Kabel mit den
mit dem Produkt gelieferten Kabelbindern zusammengebunden werden.
Comm.
230V 50/60Hz
17
Kurzanleitung Compact Controller ZNO2050500 C 05/2021 www.eaton.com
Der CGLine+ Web-Controller wird standardmäßig mit der festen IP Adresse 192.168.1.200
ausgeliefert. Ein Betrieb über dhcp (Dynamische IP-Adressvergabe) ist möglich, aber ab
Werk nicht aktiviert.
Da typische Firmennetzwerke eigene IP-Adressbereiche für unterschiedliche Anwendungen
nutzen, ist es notwendig die Netzwerkeinstellungen des CGLine+ Web-Controllers mit
einem PC oder Notebook über eine Direktverbindung zu konfigurieren.
Der zu konfigurierende PC muss sich im selben Subnetz des Controllers befinden, d.h.
ab Werk im Subnetz 192.168.1.xxx (letzte Stelle ungleich 200), z.B. 192.168.1.50 (Subnetz
255.255.255.0).
Einstellungen für Gateway oder DNS sind bei einer direkten Verbindung nicht notwendig.
3. ERSTER START
a
CGLine+ Compact
CGLine+ Compact
1.Benutzer
230V/AC
CGLine+ Compact
2.Administrator
Der CGLine+ Web Compact Controller ist ab sofort einsatzbereit!
b
c
11:40
Z1
CGLine+ Compact
Login
Strang 1
Strang 2
Z2 Z3 Z4
Betrieb
Blockiert
Fehler Test
Keine Leuchte
d
Sobald der CGLine+ Web
Compact Controller
eingeschaltet wird, erscheint
ca. 3 Sekunden lang eine
Ladeseite.
Anschließend wird eine Übersicht über die Installation dargestellt. Sie können eine
Störung schnell und leicht identifizieren, da diese anhand der Zone und dem Strang
abgebildet wird.
Wählen Sie Benutzer, um ein
neues Passwort auszuwählen.
Geben Sie das Passwort
standardmäßig "GUEST" ein
und geben Sie ein neues
Passwort ein (6 Zeichen
mindestens).
Dann mit Speichern validieren.
Gehen Sie zurück zur
vorherigen Ansicht.
Wählen Sie Admin, um ein
neues Passwort auszuwählen.
Geben Sie das Passwort
standardmäßig "EATON" ein
und geben Sie ein neues
Passwort ein (6 Zeichen mind-
estens).
Dann mit Speichern validieren.
Passwörter für ,,Benutzer" und ,,Administrator" müssen während der ersten Verbindung
geändert werden. Wählen Sie Administrator und geben Sie das Passwort standardmäßig
"EATON" ein.
11:40 Admin
21/01/2020
Altes Passwort
Speichern
Neues Passwort
Bestätigung neues Passwort
Abbruch
X
11:40 Benutzer
21/01/2020
Altes Passwort
Speichern
Neues Passwort
Bestätigung neues Passwort
Abbruch
X
18 Kurzanleitung Compact Controller ZNO2050500 C 05/2021 www.eaton.com
4. ALLGEMEINE KONFIGURATION
aMelden Sie sich als "Admin"
an, mit dem zuvor gewählten
Passwort.
Anschließend können Sie
"Befehle" auswählen.
11:40
Admin
21/01/2020
4.Befehle
11:40
Login : Admin
Passwort
21/01/2020
SpeichernAbbruch
X
a
b
4.1. Spracheinstellung
Melden Sie sich als Admin an,
mit dem zuvor gespeicherten
Passwort.
Wählen Sie anschließend im
Hauptmenü ,,Konfiguration".
11:40
Login : Admin
Passwort
21/01/2020
SpeichernAbbruch
X
11:40
Admin
21/01/2020
3.Konfiguration
11:40
Admin
21/01/2020
>Konfiguration
1.Allgemein
2.Test
3.Eingang
4.Ausgang
5.Netzwerk
6.E-Mail
7.Adresse
Auswahl
11:40
Admin
21/01/2020
>Konfiguration->Allgemein
1.Name
2.Passwort ändern
3.Zeit
4.Datum
5.Sprache
Auswahl
11:40
Admin
21/01/2020
>Konfiguration->Allgemein->Sprache
1.English
2.Français
3.Deutsch
4.Italian
5.Portuguese
6.Nederlands
Auswahl
c
Unter "Allgemein" können Sie
eine "Sprache" auswählen.
Schließlich können Sie die aus-
gewählte Sprache speichern.
4.3. Initialisierung der Leuchten
4.2. Datum- und Zeiteinstellung
Bleiben Sie im Menü
"Allgemein" und aktu-
alisieren Sie die "Uhrzeit"
und das "Datum". Wählen Sie
"Speichern", um ihre Eingabe zu
speichern.
11:40
Admin
21/01/2020
Datum (dd/mm/yyyy)
Speichern
21/01/2020
Abbruch
X
11:40
Admin
21/01/2020
Uhrzeit (hh:mm)
Speichern
11:40
Abbruch
X
19
Kurzanleitung Compact Controller ZNO2050500 C 05/2021 www.eaton.com
bUnter "Adressierte Befehle" kön-
nen Sie "Alle Stränge" auswählen.
11:40
Admin
21/01/2020
>Befehle
1.Adressierte Befehle
2.Allgemeine Befehle
3.Adaptive Evacuation
Auswahl
11:40
Admin
21/01/2020
>Initialisierungsbefehle
1.Alle Stränge
2.Strang 1 1 ( 5 Leuchten)
3.Strang 1 2 (0 Leuchten)
Auswahl
c
11:40
Admin
21/01/2020
>All Stränge
1.Alle Leuchten neu suchen
2.Nur neue Leuchten suchen
3.Suche initialisierte Leuchten
4. Konfiguration PCSoft neu laden
Auswahl
11:40
Admin
21/01/2020
Normalbetrieb
Strang_1 : 5 Strang_2 : 0
Wählen Sie "Alle Leuchten neu
suchen" aus und warten Sie bis
der Ladeprozess vollständig
abgeschlossen ist.
Überprüfen Sie die Anzahl der
angezeigten Leuchten und
klicken Sie auf .
dOPTIONAL: Sie können die
Einstellungen vom automatisch-
en Test ändern.
Hierzu müssen Sie zurück
zum Hauptmenü und dann
"Konfiguration" auswählen.
Anschließend können Sie "Test"
auswählen.
11:40
Admin
21/01/2020
3.Konfiguration
11:40
Admin
21/01/2020
>Konfiguration
1.Allgemein
2.Test
3.Eingang
4.Ausgang
5.Netzwerk
6.E-Mail
7.Adresse
Auswahl
Wählen Sie die "Test Gruppe"
aus, die aktualisiert werden
soll. Anschließend können Sie
die Art des Testes auswählen
und diesen konfigurieren.
11:40
Admin
21/01/2020
>Konfiguration->Test Gruppe 1
1.Funktiontest
2.Batterietest
Auswahl
11:40
Admin
21/01/2020
>Nächster Funktionstest
1.Zeit : 18:00
2.Datum : 01/01/2099
3.Test Intervall : 07 Tage
4.Speichern
Auswahl
Wenn Sie die gewünschten
Einstellungen vorgenom-
men haben, können Sie diese
"Speichern".
11:40
Admin
21/01/2020
>Nächster F
1.Zeit : 18:00
2.Datum : 01/01/2099
3.Test Intervall : 07 Tage
4.Speichern
Auswahl
Conguration Saved
eDer CGLine+ Web Compact Controller wurde nun mit den grundlegenden Einstellungen
konfiguriert. Weitere Details entnehmen Sie bitte der ausführlichen Montage- und
Bedienungsanleitung.
Falls eine oder mehrere
Leuchten fehlen, lesen Sie bitte
die vollständige Montage- und
Betriebsanleitung.
20 Kurzanleitung Compact Controller ZNO2050500 C 05/2021 www.eaton.com
5. EINSTELLUNG DER PC-NETZWERKKARTE
Markieren Sie “Internetprotokoll
Version 4” 1 und klicken auf
„Eigenschaften“ 2.
Ändern der Netzwerkeinstellungen am PC:
Um die Netzwerkeinstellungen der Netzwerkkarte des PCs zu ändern, öffnen Sie
bitte die Systemsteuerung in Windows
Netzwerk und Freigabecenter
Adaptereinstellung ändern
Mausklick rechts auf LAN-Verbindung
Folgendes Fenster öffnet sich:
1
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Eaton CGLine+ Web Compact Controller Manuel utilisateur

Taper
Manuel utilisateur