GE AJCQ14DWJ Le manuel du propriétaire

Taper
Le manuel du propriétaire
Write the model and serial
numbers here:
Model # _________________
Serial # _________________
You can find the this information
on a label attached to the right
side of the chassis.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
AIR CONDITIONER
26” Built-In Wi-Fi
49-5000760 Rev. 1 09-23 GEA
ESPAÑOL
For a Spanish version of this
manual, visit our Website at
GEAppliances.com.
Para consultar una version
en español de este manual
de instrucciones, visite nuestro
sitio de internet
GEAppliances.com.
SAFETY INFORMATION .........3
USING THE AIR
CONDITIONER ..............4
WI-FI SETUP ......................7
CARE AND CLEANING ...........9
INSTALLATION
INSTRUCTIONS ..............10
TROUBLESHOOTING TIPS ......12
CONSUMER SUPPORT
Warranty ............................15
Consumer Support ....................16
OWNER’S MANUAL &
INSTALLATION
INSTRUCTIONS
Cool Only Models
AJCQ06LWJ
AJCQ08AWJ
AJCQ10AWJ
AJCQ10DWJ
AJCQ12AWJ
AJCQ12DWJ
AJCQ14DWJ
Cool Only High Mount Models
AJCM08AWJ
AJCM10AWJ
AJCM10DWJ
AJCM12DWJ
Heat/Cool Models
AJEQ08AWJ
AJEQ10DWJ
AJEQ12DWJ
AJEQ14DWJ
Heat/Cool High Mount Models
AJEM12DWJ
249-5000760 Rev. 1
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
49-5000760 Rev. 1 3
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
For your safety, the information in this manual must be followed to minimize the risk of
fire, electric shock or personal injury.
Ŷ8VHWKLVDSSOLDQFHRQO\IRULWVLQWHQGHGSXUSRVHDV
described in this Owner’s Manual.
ŶThis air conditioner must be properly installed in accordance
with the Installation Instructions before it is used.
ŶNever unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
ŶReplace immediately all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced with a
new power supply cord obtained from the manufacturer
and not repaired. Do not use a cord that shows cracks
or abrasion damage along its length or at either the
plug or connector end.
ŶTurn the unit OFF and unplug your air conditioner
before cleaning.
ŶFor your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
ŶIf the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician.
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Ŷ'2127XVHDQH[WHQVLRQFRUGZLWKWKLVair
conditioner.
Ŷ'2127XVHVXUJHSURWHFWRUVRUPXOWLRXWOHW
adaptors with this air conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety,
this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the possibility
of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test
and reset button is provided on the plug case. The device
should be tested on a periodic basis by first pressing the
TEST button and then the RESET button while plugged
into the outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue use of the
air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its
own individual electrical outlet which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a
fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical connection
requirements.
WARNING
READ AND SAVE THESE INSTRUCTIONS
For appliance recycling information please visit GEAppliances.com/recycling.
WARNING
449-5000760 Rev. 1
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
Risk of Fire or Explosion. This unit contains flammable refrigerant. Additional safety
precautions must be followed.
Ŷ'RQRWXVHPHDQVWRDFFHOHUDWHWKHGHIURVWLQJ
process or to clean, other than those recommended
by the manufacturer.
ŶThe appliance shall be stored in a room without
FRQWLQXRXVO\RSHUDWLQJLJQLWLRQVRXUFHVIRUH[DPSOH
open flames, an operating gas appliance or an
operating electric heater.
ŶDo not pierce or burn refrigerant tubing. Be aware
that refrigerants may not contain an odor.
ŶKeep ventilation openings clear of obstruction.
ŶWhen handling, installing, and operating the
appliance, care should be taken to avoid damage to
the refrigerant tubing.
ŶDo not drill holes in the unit.
ŶMaintenance, cleaning, and service should only
be performed by technicians properly trained and
qualified in the use of flammable refrigerants.
ŶGEAppliances does not support any servicing of
sealed system components (i.e. refrigerant containing
parts) in the air conditioner.
ŶDispose of air conditioner in accordance with Federal
and Local Regulations. Flammable refrigerants
require special disposal procedures. Contact your
local authorities for the environmentally safe disposal
of your air conditioner.
WARNING
For appliance recycling information please visit GEAppliances.com/recycling.
FCC Compliance Statement:
7KHGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&5XOHV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
READ AND SAVE THESE INSTRUCTIONS
49-5000760 Rev. 1 5
Air Conditioner Controls
Appearance may vary.
ŶTo ensure proper operation, aim the remote control at the
control panel on the air conditioner.
ŶThe remote control signal has a range up to 21 feet.
ŶThe remote control will control the unit even if
connected to the Wi-Fi.
ŶMake sure nothing is between the air conditioner and
the remote control that could block the signal.
ŶMake sure the battery is fresh and installed correctly—
see the Care and Cleaning section.
Remote Control
Lights above the functions on the control panel indicate
the selected settings
Using the Air Conditioner - Controls
USING THE AIR CONDITIONER
1. POWER
Turns air conditioner on and off.
2. DISPLAY
Displays the temperature setting.
3. MODE
8VHWRVHWHEAT (on some models), COOL, FAN, ECO,
or DRY modes. Indicator lights on the controls will show
the mode selected.
4. TEMP INCREASE (+) / DECREASE (–)
8VHWRVHWWHPSHUDWXUHZKHQLQ+($7RQVRPHPRGHOV
COOL, ECO, or DRY modes.
5. FAN SPEED
8VHWRVHWWKHIDQVSHHGDWAUTO, LOW, MEDIUM, or
HIGH. Indicator lights will show the speed selected.
6. FILTER
Monitors accumulated fan run time as a reminder to clean
the filter.
7. WI-FI
This unit is GE Appliances Wi-Fi Connect Enabled.
Indicator will light up when Wi-Fi is active.
8. SLEEP
Allows room temperature to increase in Cool mode or
decrease in Heat mode during sleeping hours.
649-5000760 Rev. 1
Using the Air Conditioner - Features
To Adjust Fan Speeds
Press FAN SPEED to select the FAN SPEED in four
steps - AUTO, LOW, MED, or HIGH. Each time the FAN
SPEED is pressed, the fan speed mode is shifted.
For some models, the fan speed can not be adjusted
under HEAT mode. In DRY mode, the fan speed is
controlled at low automatically.
In AUTO, the fan speed will automatically operate at the
speed needed to provide optimum comfort. If the room
needs faster cooling to meet the set temperature, the
fan will automatically increase. If the room needs less
cooling, the fan will automatically decrease.
SLEEP
Press the Sleep button to initiate the sleep mode. In this
mode, the selected temperature will increase (cooling)
or decrease (heating) by 2°F / 1°C 30 minutes after the
mode is selected.
The temperature will then increase (cooling) or decrease
(heating) by another 2°F / 1°C after an additional 30
minutes.
This new temperature will be maintained for 7 hours
before it returns to the originally selected temperature.
This ends the Sleep mode and the unit will continue
to operate as originally programmed. The Sleep mode
program can be cancelled at any time during operation
by pressing the Sleep button again.
Check Filter
Press FILTER to initiate this feature. This feature is a
reminder to clean the air filter for more efficient operation. The LED (light) will illuminate after 250 hours of
operation. To reset after cleaning the filter, press FILTER
and the light will go off.
Control Panel Lights
This unit has a feature that turns the control panel lights
on or off when there is no activity for more than 1 minute.
To wake up the lights, press any pad on the controls and
the lights will come on to show the previous settings.
To turn this feature off, press and hold SLEEP for 3
seconds. The unit will beep to signal a successful toggle
off of this feature.
Pressing DISPLAY on the wireless remote will turn the
control panel lights off immediately.
To Select the Operating Mode
To choose operating mode, press MODE. Each time you
press MODE, a new mode is selected in a sequence that
goes from HEAT (on some models), COOL, FAN, ECO,
and DRY only. The indicator light will be illuminated and
remain on once the mode is selected.
To operate in FAN only Mode:
Ŷ8VHWKLVIXQFWLRQRQO\ZKHQFRROLQJRUKHDWLQJRQVRPH
models) is not desired. You can choose any fan speed
you prefer.
ŶDuring this function, the display will show the actual
room temperature, not the set temperature in the
cooling or heating (on some models) mode.
ŶIn FAN only mode, the temperature is not adjustable.
To operate in ECO Mode:
Ŷ
With this feature, the unit will operate in COOL mode
only. The fan will operate with the compressor to
cool the space. The fan will continue to run for 3
minutes after the compressor stops and the room
set temperature has been met. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set point, at which time the
compressor turns on and cooling starts.
To operate in DRY Mode:
Ŷ
In this mode, the air conditioner will generally operate in
the form of a dehumidifer. Since the conditioned space
is a closed or sealed area, some degree of cooling
will occur. In DRY mode, the fan operates in LOW fan
speed only.
Fahrenheit vs. Celsius
To change the temperature display between Fahrenheit to Celsius, press and + together and hold for 3 seconds.
Control Panel Sound
To disable the audible beep when buttons are pressed, press FILTER for 3 seconds. To enable the beeping you can
re-press FILTER for 3 seconds.
USING THE AIR CONDITIONER
49-5000760 Rev. 1 7
USING THE AIR CONDITIONER
Using the Air Conditioner - Features
Additional Features
The “Cool” circuit has an automatic 3 minute delayed
start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker
tripping. The fan will continue to run during this time.
There is a 2 second delay for the compressor to stop when
selecting fan or heat. This is to cover the possibility of
having to roll through to select another mode.
The control will maintain the set temperature within 1°F
between 62°F and 86°F in cool or heat mode (on some
models).
After a power outage, the unit will remember last setting
and return the unit to that setting when power is restored.
Air Direction
Adjustable louvers control air flow direction.
The louvers will allow you to direct the air flow up or down
and left or right throughout the room as needed until the
desired left/right direction is obtained. Pivot horizontal
louvers until the desired up/down direction is obtained.
Remote Wall Thermostat (Heat/Cool models only)
All heat/cool models are capable of being controlled by a
24 VAC remote wall thermostat. The thermostat control
connection board is located behind a metal cover on the
right side of the metal chassis cover. To open the cover,
remove the Phillips head screw and lift from the slots at the
bottom. To properly connect the wiring from a remote wall
WKHUPRVWDWIROORZWKHVHVWHSV
1. Order the 8-pin connector from GE Appliances Service.
Call 1-800-626-2002 and order WP26X24981. A
connector is required for each unit being controlled by
a wall thermostat
2. Install the remote thermostat according to the
directions included with it.
8VLQJZLUHQXWVLQFOXGHGZLWKWKHSLQFRQQHFWRU
connect the wiring from the wall thermostat per the
following; (Proper connection of the wiring is critical.
Improper hookups could result in damage to the air
conditioner components and may not be covered by
the product warranty) After properly making the wire
nut connections, wrap the 7 connectors together with
electrical tape and push them into the lower right
FRUQHURIWKHFRQWUROER[RSHQLQJWRNHHSWKHPRXWRI
the way. Route the thermostat wiring out the bottom of
the opening at the notch and replace the metal cover.
Ventilation
To open the ventilation port, remove the adjustable air discharge louvers by gently pulling forward the right end until
it is released from the pivot point. Shift the louvers to the right to release the left end from its pivot point. To open the
ventilation port, pull the lever forward. The lever will lock in place. To replace the air discharge louvers, reverse the
above procedure
NOTE: When the thermostat is installed and power
is applied, the control display will not illuminate
and the unit is automatically controlled by the wall
thermostat.
NOTE: When using Wi-Fi, a remote wall thermostat
will not function. If a thermostat is installed, Wi-Fi
has operation priority.
Do Not Operate the unit in COOL mode when outdoor
temperatures are below 64ºF(18ºC).
Vent Door Open Vent Door Closed
Connector Wire Color Codes Thermostat Connections
Black Common
White Electric Heater
Yellow Compressor
Blue Not used
Green Fan High
Tan Fan Low
Red 24 VAC
849-5000760 Rev. 1
WIFI SETUP
WiFi Setup
GE Appliances SmartHQ (for customers in the United States)
GE Appliances SmartHQ Enabled. If your Air Conditioner (AC) has a Connected Appliance Information label
located on the outside as shown below, your AC is GE Appliances SmartHQ Enabled. A WiFi
communication
card is built into the product allowing it to communicate with your smart phone for remote monitoring, control and
notifications. Please visit GEAppliances.com/connect to learn more about connected appliance features, and to learn
what connected appliance apps will work with your smart phone.
UPD ID:
XX-XX-XX-XX-XX
MAC:
XXXXXXXXXXXX
FCC ID: ZKJ-WCATA006
IC: 10229A- WCATA006
Network:
GE_MODULE_XXXX
MAC:
XXXXXXXXXXXX
FCC ID: ZKJ-WCATA006
IC: 10229A- WCATA006
Password:
XXXXXXXX
:L)L&RQQHFWLYLW\)RUDVVLVWDQFHZLWKWKHDSSOLDQFHRUWKHConnectPlus network connectivity (for models that are WiFi
enabled or WiFi optional), please call 1-800-220-6899.
49-5000760 Rev. 1 9
WiFi Setup
How it Works
Download the GE
Appliances SmartHQ App
8VHWKHDSSWRFRQQHFW\RXUURRPDLU
conditioner to WiFi Once connected, use the app to turn
down your air conditioner as you
leave work.
CHANGE TEMP
TO 65
Getting Started
To connect your room air conditioner, you’ll need to open
the Appliances SmartHQ App. The app will walk you
through the connection process. Download the app from
iTunes or Google Play.
All connected appliance data is held in strict accordance
with the GE Appliances Connected Data Privacy Policy.
Visit geappliances.com/privacy/privacy_policy_
connected to view this policy.
Questions about SmartHQ
Get answers you need about setting up WiFi appliances
and connecting to your home network in our support
articles.
Visit products.geappliances.com/appliance/gea-
support-search-content to view wifi connect room air
conditioner support articles.
REGULATORY INFORMATION
FCC/IC Compliance Statement:
This device complies with Part 15 of the FCC Rules.
2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio
or television reception, which can be determined by
turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the
IROORZLQJPHDVXUHV
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
&RQVXOWWKHGHDOHURUDQH[SHULHQFHGUDGLRWHOHYLVLRQ
technician for help.
Labelling: Changes or modifications to this unit not
H[SUHVVO\DSSURYHGE\WKHPDQXIDFWXUHUFRXOGYRLGWKH
users authority to operate the equipment.
This product has Wi-Fi capability and requires
Internet connectivity and a wireless router to enable
interconnection with an Energy Management System,
DQGRUZLWKRWKHUH[WHUQDOGHYLFHVV\VWHPVRU
applications.
WIFI SETUP
10 49-5000760 Rev. 1
CARE AND CLEANING
Care and Cleaning
How to Insert the Batteries in the Remote Control
1. Remove the battery cover by sliding it according to the
arrow direction.
2. Insert new batteries, making sure that the (+) and (-) of
battery are installed correctly.
3. Reattach the cover by sliding it back into position.
NOTES:
8VH³$$$´YROWDONDOLQHEDWWHULHV'RQRWXVH
rechargeable batteries
Remove the batteries from the remote control if the
system is not going to be used for a long time.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged with dirt or soot, they may need to
be professionally cleaned, a service available through
GE Appliances service or other service companies.
Front Grille Removal
The front grille can be removed for a more thorough
cleaning.
To remove:
1. Grasp the front grille louvers on both sides at the
recess and pull forward
2. Remove the filter by pulling forward and out.
3. Grasp the bottom of the grille and carefully pull
forward about 1” or until the security brackets limit the
travel forward.
4. Remove the two Phillips head screws located in the
upper corners of the grille louver opening.
5. Grasp the left and right rear edges of the grille about
6” from the top and pull outward to release the tabs
on the inside of the grille from the slots in each side of
the metal chassis cover. When released pull out both
bottom corners of the grill while carefully lifting up to
release the 4 tabs on the inside top of the grille from
the slots in the metal chassis cover
6. To release the multi-pin low-voltage electrical
connector from the user interface, press the rear of
the tab and gently pull apart.
Front Grille Re-installation:
1. Reconnect the multi-pin low voltage connector.
2. Before engaging the 4 tabs on the inside top of the
grille, align the ventilation lever on the chassis into
the mating slot on the inside of the discharge opening
in the grille. After ensuring proper alignment of the
ventilation lever, push the grille toward the chassis
and the tabs should snap into the slots on the metal
chassis cover.
Air filter
To access the filter, grasp the front grille louvers on both
sides at the recess and pull forward. Remove the filter by
lifting up and out. Note the filter direction when
re-installing.
Wash the filter using liquid dishwashing detergent and
warm water. Rinse the filter thoroughly. Gently shake
H[FHVVZDWHUIURPWKHILOWHU
Be sure the filter is thoroughly dry before replacing. Or,
instead of washing, you may vacuum the filter until clean.
NOTE: Never use hot water over 104°F (40°C) to clean
the air filter. Never attempt to operate the unit without the
air filter.
Energy Saving Note
,QRUGHUWRUHDFKPD[LPXPHQHUJ\VDYLQJDQGFRPIRUWLW
is recommended to use a cover to insulate the unit when
the unit is not in use. The recommended cover size for
WKHXQLWLV´[´[´:[+['
NOTE:8QSOXJWKHXQLWEHIRUHLQVWDOOLQJDFRYHU
Cabinet
Be sure to unplug the air conditioner to prevent shock or
fire hazard. The cabinet and front may be dusted with an
oil-free cloth or washed with a cloth dampened in a solution
of warm water and mild liquid dishwashing detergent.
Rinse thoroughly with a damp cloth and wipe dry.
1HYHUXVHKDUVKFOHDQHUVZD[RUSROLVKRQWKHFDELQHWIURQW
%HVXUHWRZULQJH[FHVVZDWHUIURPWKHFORWKEHIRUH
ZLSLQJDURXQGWKHFRQWUROV([FHVVZDWHULQRUDURXQG
the controls may cause damage to the air conditioner.
Plug in the air conditioner.
49-5000760 Rev. 1 11
INSTALLATION INSTRUCTIONS
Installation Instructions
For more help, visit GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these
instructions for local inspector’s use.
IMPORTANT – Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time ±$SSUR[LPDWHO\KRXU
We recommend that two people install this
product.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
 <RX0867XVHSURSHULQVWDOODWLRQSURFHGXUHVDV
described in these instructions when installing this
air conditioner.
Power cord includes a current interrupter device. A
TEST and RESET button are provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
ELECTRICAL REQUIREMENTS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
For Existing Wall Sleeves
)RU([LVWLQJ:DOO6OHHYHV
1RWHWKDWWKHDLUFRQGLWLRQHUGLPHQVLRQVDUH
Width-26”
Height-15 ¾”
Depth-18 ¼” (without front cover)
Depth-16” (rear of chassis to rear edge of front grille)
Install air conditioner according to these instructions
to achieve the best performance. Installing this air
FRQGLWLRQHULQH[LVWLQJVOHHYHVWKDWGRQRWDOORZIRU
proper fit or have proper outdoor grilles may affect
performance and could void the manufacturer’s
warranty.
Parts Included
• Security bracket and screws for a 26” wall sleeve (2)
• Remote Control (1)
IMPORTANT NOTE
For optimal energy efficiency and performance, we
recommend using the RAB26A or the RAB46B wall
sleeves with the RAG13A rear grille.
CAUTION
12 49-5000760 Rev. 1
INSTALLATION INSTRUCTIONS
Installation Instructions
Weather Seal Strips Installation
Ŷ7RLPSURYHVHDOLQJRQQRQ*(:DOO6OHHYHVRU
older wall sleeves that have damaged or missing
gaskets, we have provided two foam pads with
adhesive that can be installed on the sides of the
chassis per the below instructions.
Note: These gaskets may not be necessary with a
new RAB26A sleeve install.
1. Remove all packaging and packing material from
the unit.
2. Put the chassis on a table or install it
DSSUR[LPDWHO\ôRIWKHZD\LQWRWKHVOHHYH
3. Locate the “bump” or raised area in the metal on
each side of the unit right behind the front cover.
The foam strip should be located right behind the
raised area.
4. Wipe each side with a cloth to make sure the area
is clean.
5. Peel the backing off one piece of foam and starting
at the top corner of side, adhere it from top to
bottom just behind the bump on the flat surface.
6. Repeat on right side ensuring you do not put the
foam strip over the removable cover on the right
side.
7. When sliding the unit into the sleeve gently
compress the pads to help it move behind the
flange of the sleeve.
8. Be cautious of the foam pads when removing the
unit from the sleeve as well.
Security Brackets Installation
(It is important to install these brackets
to prevent the chassis from being
pushed into the room from the outside.)
Ŷ
The brackets must be installed so the flanges are
hooked behind the inside flanges of the wall sleeve.
8VLQJWKHVFUHZVSURYLGHGDWWDFKWKHEUDFNHWVRQ
the sides of the chassis.
To install the security bracket without fully removing
WKHIURQWJULOOH
1. Grasp the front cover louvers on both sides at the
recess and pull forward.
2. Remove the filter by pulling forward and out.
3. Remove the two Phillips head screws located in
the upper corners of the grille louver opening. Do
not discard screws.
4. Grasp the left and right rear edges of the front
cover about 6” from the top and pull outward to
release the tabs on the inside of the grille from
the slots in each side of the metal chassis cover.
When released pull out both bottom corners of the
IURQWJULOOHDERXW´WRH[SRVHWKHWZRVFUHZKROHV
on the lower area of the metal chassis cover.
5. Locate the 2 metal brackets stamped 26” that were
included with the air conditioner. Hook the short
flange of the bracket behind the sleeve inside edge
and rotate it so the long side can be pressed flat
against the metal chassis cover. Adjust so the
bracket can be secured to the metal chassis cover
by 2 screws included with the bracket. Only one
bracket will be needed and can be installed on
either side of the chassis.
6. To reinstall the front grille, push the lower corners
to toward the sleeve until the side tabs click into
the mating slots. Reinstall the two screws removed
earlier and replace the filter and louvers.
Hook inside
sleeve edge
and secure
to unit
Hook inside
sleeve edge
and secure
to unit
Raised
Area
Locate foam
pad here
Removable
cover
Left Side Right Side
49-5000760 Rev. 1 13
Troubleshooting Tips... Before you call for service
TROUBLESHOOTING TIPS
Problem Solution
Air conditioner does
not start Wall plug disconnected. Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type
or reset circuit breaker.
Plug current device tripped. Press the RESET button.
Power is OFF. Turn power ON.
Air from the unit does
not feel cold enough Room temperature below 62°F (17°C). Cooling may not occur until room
temperature rises above 62°F (17°C).
Temperature sensor behind air filter may be touching cold coil. Keep it from the
cold coil.
Set to a lower temperature.
Compressor stopped when changing modes. Wait for 3 minutes after set to the
COOL mode.
Air conditioner cooling,
but room is too warm.
Ice is forming on
cooling coil behind
decorative front.
Outdoor temperature below 64°F (18°C). To defrost the coil, set FAN ONLY mode.
Air filter may be dirty. Clean the filter. Refer to Care and Cleaning section. To
defrost, set to FAN ONLY mode.
Thermostat set to cold for night-time cooling. To defrost the coil, set to FAN
ONLY mode. Then, set temperature to a higher setting.
Dirty air filter, or the air is restricted. Clean the air filter. Refer to Care and
Cleaning section.
Temperature is set too high. Set the temperature to a lower setting.
Air directional louvers positioned improperly. Position louvers for better air
distribution.
Front of unit is blocked by drapes, blinds, furniture, etc, which restricts air
distribution. Clear blockage in front of unit.
Doors, windows, registers, etc, may be open. Close doors, windows, registers.
Unit recently turned on in hot room. Allow additional time to remove “stored
heat” from walls, ceiling, floor, and furniture.
Air conditioner turns on
and off rapidly Dirty air filter, the air is restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a higher setting to cool
outdoor cooling coil.
Noise when unit is
cooling Air movement sound. This is normal. If too loud, set to a slower FAN setting.
Improper installation. Refer to installation instructions or check with installer.
Water dripping INSIDE
when unit is cooling Improper installation. Tilt air conditioner slightly to the outside to allow water
drainage. Refer to installation instructions, and check with installer.
Water dripping
OUTSIDE when unit is
cooling
Unit removing large quantity of moisture from humid room. This is normal
during excessively humid days.
Room too cold Set temperature to low. Increase set temperature.
Error code “AS” in the
display Room temperature sensor error. Unplug the unit and plug it back in. If error
repeats, call for service. NOTE: In Fan only mode, it will display “LO” or “HI”.
Error code “HS” in the
display Electric heating sensor error. Unplug the unit and plug it back in. If error
repeats, call for service.
Error code “” in the
display Evaporator temperature sensor error. Unplug the unit and plug it back in. If
error repeats, call for service.
14 49-5000760 Rev. 1
Notes
49-5000760 Rev. 1 15
GE Appliances Air Conditioner Limited Warranty
Staple your receipt here. Proof of the original purchase date
is needed to obtain service under the warranty.
LIMITED WARRANTY
ŶService trips to your home to teach you how to use
the product.
ŶImproper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
ŶFailure of the product resulting from modifications
to the product or due to unreasonable use including
failure to provide reasonable and necessary
maintenance.
ŶIn commercial locations, labor necessary to move the
unit to a location where it is accessible for service by
an individual technician.
ŶReplacement of house fuses or resetting of circuit
breakers.
ŶFailure due to corrosion on models not corrosion-
protected.
ŶDamage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
ŶIncidental or consequential damage caused by
possible defects with this air conditioner.
ŶDamage caused after delivery.
What GE Appliances Will Not Cover:
7KLVOLPLWHGZDUUDQW\LVH[WHQGHGWRWKHRULJLQDOSXUFKDVHUDQGDQ\VXFFHHGLQJRZQHUIRUSURGXFWVSXUFKDVHG
IRUKRPHXVHZLWKLQWKH86$,IWKHSURGXFWLVORFDWHGLQDQDUHDZKHUHVHUYLFHE\D*($SSOLDQFHV$XWKRUL]HG
Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an
$XWKRUL]HG*(6HUYLFHORFDWLRQIRUVHUYLFH,Q$ODVNDWKHOLPLWHGZDUUDQW\H[FOXGHVWKHFRVWRIVKLSSLQJRUVHUYLFH
calls to your home.
6RPHVWDWHVGRQRWDOORZWKHH[FOXVLRQRUOLPLWDWLRQRILQFLGHQWDORUFRQVHTXHQWLDOGDPDJHV7KLVOLPLWHGZDUUDQW\
gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: GE Appliances, a Haier company
Louisville, KY 40225
All warranty service must be provided by our Factory Service Centers, or an authorized Customer Care® technician.
To schedule service, visit us on-line at GEAppliances.com/service, or call 800.GE.CARES (800.432.2737). Have
serial number and model number available when calling for service. In Canada, contact your distributor.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to two years or the shortest period allowed by law.
For The Period Of: GE Appliances Will Replace:
Two Years
From the date of the
original purchase
*($SSOLDQFHV:LOO5HSODFH$Q\SDUWRIWKHDLUFRQGLWLRQHUZKLFKIDLOVGXHWRDGHIHFWLQ
materials or workmanship. During this limited two-year warranty, GE Appliances will also
provide, free of charge, all labor and related service to replace the defective part.
Five Years
From the date of the
original purchase
*($SSOLDQFHV:LOO5HSODFH$Q\SDUWRIWKHVHDOHGUHIULJHUDWLQJV\VWHPWKHFRPSUHVVRU
condenser, evaporator, reversing valve, and all connecting tubing) which fails due to a defect
in materials or workmanship. During this three-year additional warranty, GE Appliances will
also provide, free of charge, all labor and related service to replace the defective part.
16 49-5000760 Rev. 1
Printed in China
Consumer Support
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day
of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support
VHUYLFHVGHVLJQHGIRU\RXUFRQYHQLHQFH,QWKH86GEAppliances.com In Canada, contact your distributor.
Register Your Appliance
Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced
communication and prompt service under the terms of your warranty, should the need arise. You may also mail in
WKHSUHSULQWHGUHJLVWUDWLRQFDUGLQFOXGHGLQWKHSDFNLQJPDWHULDO,QWKH86GEAppliances.com/register
Schedule Service
([SHUW*($SSOLDQFHVUHSDLUVHUYLFHLVRQO\RQHVWHSDZD\IURP\RXUGRRU*HWRQOLQHDQGVFKHGXOH\RXUVHUYLFHDW
\RXUFRQYHQLHQFHDQ\GD\RIWKH\HDU,QWKH86GEAppliances.com/service or call 800.432.2737 during normal
business hours.
For Canadian customers, call your distributor for service and/or replacement parts.
Extended Warranties
3XUFKDVHD*($SSOLDQFHVH[WHQGHGZDUUDQW\DQGOHDUQDERXWVSHFLDOGLVFRXQWVWKDWDUHDYDLODEOHZKLOH\RXU
warranty is still in effect. You can purchase it on-line anytime. GE Appliances Services will still be there after your
ZDUUDQW\H[SLUHV,QWKH86GEAppliances.com/extended-warranty or call 800.626.2224 during normal
business hours.
For Canadian customers, contact your distributor.
CONSUMER SUPPORT
Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes
(VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.
,QWKH86GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be exercised, since improper
servicing may cause unsafe operation.
For Canadian customers, contact your distributor.
Contact Us
If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the
GHWDLOVLQFOXGLQJ\RXUSKRQHQXPEHURUZULWHWR
,QWKH86*HQHUDO0DQDJHU&XVWRPHU5HODWLRQV_*($SSOLDQFHV$SSOLDQFH3DUN_/RXLVYLOOH.<
GEAppliances.com/contact
For Canadian customers, contact your distributor.
Transcrivez les numéros de modèle
et de série ici :
# de modèle _____________
# de série _______________
Vous trouverez l’étiquette
signalétique sur le côté du
climatiseur.
GE est une marque déposée de General Electric Company. Fabriqué sous licence de marque.
Le climatiseur
Climatiseur 26 po avec Wi-Fi intégré
49-5000760 Rev. 1 09-23 GEA
INFORMATION DE SÉCURITÉ ...3
UTILISANT LE CLIMATISEUR ..4
CONFIGURATION
DU WI-FI ...........................7
ENTRETIEN ET NETTOYAGE ....9
INSTRUCTIONS
D’INSTALLATION
.............. 10
CONSEILS DE DÉPANNAGE ....12
SOUTIEN AU CONSOMMATEUR
Garantie limitée ......................13
Soutien au consommateur .............14
MANUEL D’UTILISATION
ET INSTRUCTIONS
D’INSTALLATION
Modèles Cool uniquement
AJCQ06LWJ
AJCQ08AWJ
AJCQ10AWJ
AJCQ10DWJ
AJCQ12AWJ
AJCQ12DWJ
AJCQ14DWJ
Modèles à montage surélevé
uniquement cool
AJCM08AWJ
AJCM10AWJ
AJCM10DWJ
AJCM12DWJ
Modèles chaud / froid
AJEQ08AWJ
AJEQ10DWJ
AJEQ12DWJ
AJEQ14DWJ
Modèles à montage haut chaud /
froid
AJEM12DWJ
249-5000760 Rev. 1
NOUS VOUS REMERCIONS D’ACCUEILLIR GE APPLIANCES CHEZ VOUS
Que vous ayez grandi avec GE Appliances ou qu’il s’agisse de votre première acquisition, nous
sommes heureux de vous accueillir dans notre famille.
Nous sommes fiers du savoir-faire, de l’innovation et de l’esthétique qui composent chaque appareil
GE Appliances, et nous pensons que vous le serez aussi. Dans cette optique, nous vous rappelons
que l’enregistrement de votre électroménager vous assure la communication de renseignements
importants sur le produit et la garantie lorsque vous en avez besoin.
Enregistrez votre électroménager GE en ligne dès maintenant. Des sites Web et des numéros de
téléphone utiles figurent dans la section Soutien au consommateur de ce manuel d’utilisation.
49-5000760 Rev. 1 3
Pour votre sécurité, vous devez suivre les instructions de ce manuel pour
réduire les risques d’incendie, d’explosion, de choc électrique, de dommage à
la propriété, de blessure ou de décès.
Ŷ1¶XWLOLVH]FHWDSSDUHLOTXHSRXUVRQXVDJHSUpYXWHO
que décrit dans le Manuel de l’utilisateur.
Ŷ9RXVGHYH]ELHQPRQWHUFHFRQGLWLRQQHXU
conformément aux Instructions de montage, avant de
l’utiliser.
Ŷ1HGpEUDQFKH]MDPDLVYRWUHFRQGLWLRQQHXUHQWLUDQW
sur le cordon d’alimentation. Saisissez fermement la
fiche et sortez-la droit de sa prise.
Ŷ5HPSODFH]LPPpGLDWHPHQWWRXWFRUGRQG¶DOLPHQWDWLRQ
abîmé ou endommagé. Un cordon d’alimentation
électrique endommagé ne doit pas être réparé mais
plutôt remplacé par un autre cordon d’alimentation
obtenu du fabricant. N’utilisez pas un cordon
d’alimentation qui montre des fissures ou des signes
d’abrasion sur sa longueur ou encore près de la prise
ou du connecteur.
ŶeWHLJQH]HWGpEUDQFKH]YRWUHFOLPDWLVHXUDYDQWGH
procéder à une réparation ou un nettoyage.
Ŷ3RXUYRWUHVpFXULWp«QHUDQJH]MDPDLVRXQ¶XWLOLVH]
MDPDLVGHVPDWpULDX[FRPEXVWLEOHVGHO¶HVVHQFH
ou d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre appareil
électroménager.
Ŷ6LODSULVHpOHFWULTXHQ¶HVWSDVFRPSDWLEOHDYHFOD
fiche du cordon électrique, il faut faire remplacer la
prise par un électricien agréé.
UTILISATION DE RALLONGES
RISQUE D’INCENDIE. Peut occasionner des
blessures graves ou la mort.
Ŷ1(3$6XWLOLVHUGHUDOORQJHDYHFFHFRQGLWLRQQHXU
d’air.
Ŷ1(3$6XWLOLVHUGHSDUDVXUWHQVHXURXG¶DGDSWDWHXUj
prises multiples avec ce conditionneur d’air.
COMMENT BRANCHER L’ÉLECTRICITÉ
1HFRXSH]RXQ¶HQOHYH]MDPDLVODEURFKHGHPLVHj
la terre (la troisième broche de la fiche) du cordon
G¶DOLPHQWDWLRQ3RXUYRWUHVpFXULWpSHUVRQQHOOHFHW
appareil doit être bien mis à la terre.
N’utilisez PAS une fiche d’adaptation avec cet
électroménager.
Le cordon d’alimentation de cet appareil est muni d’une
fiche triphasée (mise à la terre) qui correspond à une
prise murale normale triphasée, pour réduire le danger
de secousse électrique.
Le cordon d’alimentation peut comprendre un
mécanisme d’interruption de courant. Un bouton d’essai
et de remise en marche est fourni sur le boîtier de la
SULVH9RXVGHYH]HVVD\HUOHPpFDQLVPHSpULRGLTXHPHQW
en appuyant d’abord sur le bouton TEST (essai) puis
sur le bouton RESET (remise en marche). Si le bouton
TEST ne bascule pas ou si le bouton RESET ne reste
pas enfoncé, cessez d’utiliser votre conditionneur d’air et
appelez un technicien de service qualifié.
Faites vérifier la prise murale et le circuit électrique par
un électricien qualifié pour vous assurer que la prise est
bien à la terre.
Si vous avez une prise biphasée, vous êtes
personnellement responsable et obligé de la faire
remplacer par une prise murale triphasée bien mise à la
terre.
9RXVGHYH]WRXMRXUVEUDQFKHUOHFRQGLWLRQQHXUGDQVVD
propre prise électrique, d’un voltage qui correspond à la
plaque signalétique.
Cela vous permettra d’obtenir le meilleur rendement et
empêchera la surcharge des circuits électriques de la
maison, qui risque d’occasionner un danger d’incendie.
Consultez les Instructions de montage, section des
Exigences électriques, pour les exigences de
branchements électriques particuliers.
INFORMATION DE SÉCURITÉ
INFORMATION DE SÉCURITÉ IMPORTANTES
LISEZ TOUTES LES DIRECTIVES AVANT D'UTILISER L'APPAREIL
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT
AVERTISSEMENT
449-5000760 Rev. 1
INFORMATION DE SÉCURITÉ
INFORMATION DE SÉCURITÉ IMPORTANTES
LISEZ TOUTES LES DIRECTIVES AVANT D'UTILISER L'APPAREIL
LIRE ET CONSERVER CES INSTRUCTIONS
Déclaration de conformité de la FCC :
&HWDSSDUHLOHVWFRQIRUPHjODSDUWLHGHVUqJOHVGHOD)&&6RQIRQFWLRQQHPHQWHVWDVVXMHWWLDX[GHX[
conditions suivantes :
&HWDSSDUHLOQHGRLWSDVSURYRTXHUG¶LQWHUIpUHQFHVSUpMXGLFLDEOHV
2. Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un mauvais
fonctionnement.
Riesgo de incendio o Explosión Esta unidad contiene un refrigerante inflamable. Se
deberán seguir las precauciones adicionales de seguridad.
Ŷ1RXVHPHGLRVSDUDDFHOHUDUHOSURFHVRGHGHVFRQJHODFLyQ
o para limpiar que no sean aquellos recomendados por el
fabricante.
Ŷ(VWHHOHFWURGRPpVWLFRVHGHEHUiJXDUGDUHQXQDVDOD
GRQGHQRKD\DIXHQWHVGHLJQLFLyQHQIXQFLRQDPLHQWR
FRQVWDQWHSRUHMHPSOROODPDVDELHUWDVXQ
electrodoméstico a gas en funcionamiento o un calefactor
eléctrico en funcionamiento.
Ŷ1RSHUIRUHQLTXHPHHOWXERUHIULJHUDQWH7HQJDSUHVHQWH
que los refrigerantes no deben tener olor.
Ŷ0DQWHQJDODVDEHUWXUDVGHODYHQWLODFLyQOLEUHVGH
obstrucciones.
Ŷ$OPRYHULQVWDODU\RSHUDUHOHOHFWURGRPpVWLFRVHGHEHUi
tener cuidado para evitar dañar la tubería del refrigerante.
Ŷ1RUHDOLFHSHUIRUDFLRQHVHQODXQLGDG
Ŷ(OPDQWHQLPLHQWRODOLPSLH]D\HOVHUYLFLRWpFQLFRVyOR
GHEHUiQVHUUHDOL]DGRVSRUWpFQLFRVDGHFXDGDPHQWH
entrenados y calificados en el uso de refrigerantes
inflamables.
Ŷ*($SSOLDQFHVQREULQGDVRSRUWHVREUHQLQJ~QVHUYLFLR
técnico de componentes del sistema sellado (es decir: piezas
que contengan refrigerante) del acondicionador de aire.
Ŷ'HVFDUWHHOHOHFWURGRPpVWLFRGHDFXHUGRFRQODV
5HJXODFLRQHV)HGHUDOHV\/RFDOHV/RVUHIULJHUDQWHV
inflamables requieren procedimientos de descarte
específicos. Comuníquese con las autoridades locales
para descartar su acondicionador de aire de forma
ambientalmente segura.
WARNING
3DUDREWHQHULQIRUPDFLyQVREUHHOUHFLFODMHGHHOHFWURGRPpVWLFRVYLVLWHGEAppliances.com/recycling.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

GE AJCQ14DWJ Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues