Fadini elpro-s50-T2.EFO Instructions Manual

Taper
Instructions Manual
IT
Elpro S50-T2.EFO
GB
FR
DE
IT - DISPOSITIVO DI EMERGENZA EFO (EMERGENCY FAST OPERATION)
- PREDISPOSTO PER SEMAFORO A 3 LUCI
- AUTOMATICO O SEMIAUTOMATICO
- PREDISPOSIZIONE PER OROLOGIO ESTERNO
- FUNZIONE PASSO-PASSO
- UOMO PRESENTE
GB - EFO EMERGENCY DEVICE (EMERGENCY FAST OPERATION)
- PRE-SET FOR A TRAFFIC LIGHT WITH 3 LAMPS
- AUTOMATIC OR SEMI-AUTOMATIC
- PRE-SET FOR EXTERNAL TIME CLOCK
- STEP BY STEP FUNCTION
- DEADMAN (HOLD-ON-SWITCHED) CONTROL
FR - DISPOSITIF D'URGENCE EFO (EMERGENCY FAST OPERATION)
- PREPARE POUR FEU DE CIRCULATION A 3 VOYANTS
- AUTOMATIQUE OU SEMI-AUTOMATIQUE
- PREPARE POUR HORLOGE EXTERNE
- FONCTION PAS-PAS
- HOMME MORT
DE - EFO-NOTFALLGERÄT (EMERGENCY FAST OPERATION)
- FÜR AMPEL MIT 3 LICHTERN VORGESEHEN
- AUTOMATISCH ODER HALBAUTOMATISCH
- FÜR EXTERNE UHR VORGESEHEN
- SCHRITT FÜR SCHRITT FUNKTION (IMPULSBETRIEB)
- TOTMANN-BETRIEB
PROGRAMMATORE ELETTRONICO MONOFASE/TRIFASE
PER DUE DISSUASORI A SCOMPARSA ANTITERRORISMO TALOS M50.EFO
SINGLE-PHASE/THREE-PHASE ELECTRONIC CONTROLLER
FOR TWO TALOS M50.EFO ANTI-TERRORISM RETRACTABLE BOLLARDS
PROGRAMMATEUR ÉLECTRONIQUE MONOPHASÉ-TRIPHASÉ
POUR DEUX BORNES ESCAMOTABLES ANTI-TERRORISME TALOS M50.EFO
EINPHASIGE-DREIPHASIGE ELEKTRONISCHE STEUERUNG
FÜR ZWEI TALOS M50.EFO ANTI-TERROR VERSENKBARE POLLER
Dis. N. 8949 Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422 Fax +39 0442 331054
[email protected] - www.fadini.net
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50.EFO
Elpro S50-T2.EFO
IT
2
Meccanica Fadini S.r.l.
Direttore Responsabile
DICHIARAZIONE DI CONFORMITÀ UE
Fabbricante: Meccanica Fadini S.r.l.
Indirizzo: Via Mantova, 177/A - 37053 Cerea - VR - Italy
dichiara sotto la propria responsabilità che:
Programmatore elettronico ELPRO S50-T2.EFO
è conforme alla pertinente normativa di armonizzazione dell’Unione:
- Direttiva Compatibilità Elettromagnetica 2014/30/UE
- Direttiva Bassa Tensione 2014/35/UE
Cerea, 13/10/2017
AVVERTENZE GENERALI PER LA SICUREZZA DELLE PERSONE
comprensiva di: schema e componenti dell'impianto, analisi
dei rischi, verica degli accessori di sicurezza, verica delle
forze di impatto e segnalazione dei rischi residui.
INDICAZIONI PER L'UTILIZZATORE FINALE
L'utilizzatore nale è tenuto a prendere visione e ricevere
informazioni unicamente per quanto concerne il
funzionamento dell'impianto e diviene lui stesso responsabile
del corretto uso. Deve stipulare un contratto di
manutenzione ordinaria e straordinaria (su chiamata) con
l'installatore/manutentore. Qualsiasi intervento di
riparazione deve essere eettuato solo da personale tecnico
qualicato. Conservare sempre il presente manuale di
istruzioni.
AVVERTENZE PER IL BUON FUNZIONAMENTO
DELL'IMPIANTO
Per una resa ottimale dellimpianto nel tempo e secondo le
normative di sicurezza, è necessario eseguire una corretta
manutenzione e un adeguato monitoraggio dell’intera
installazione per l’automazione, per le apparecchiature
elettroniche installate e anche per i cablaggi ad esse eettuate.
Tutta l’installazione deve essere eseguita da personale
tecnico qualicato, compilando il documento di verica e
collaudo ed il registro di manutenzione indicato nel libretto
normative di sicurezza (da richiedere o scaricare dal sito
www.fadini.net/supporto/downloads). Per l'automazione è
consigliato un controllo di manutenzione almeno ogni 6 mesi,
mentre per apparecchiature elettroniche e sistemi di sicurezza
un controllo mensile di manutenzione. Meccanica Fadini S.r.l.
non è responsabile dell'eventuale inosservanza della buona
tecnica di installazione e/o del non corretto mantenimento
dell'impianto.
SMALTIMENTO DEI MATERIALI
Gli involucri dell’imballo come cartone, nylon, polistirolo, ecc.
possono essere smaltiti eettuando la raccolta dierenziata
(previa verica delle normative vigenti nel luogo
dell'installazione in materia di smaltimento riuti). Elementi
elettrici, elettronici e batterie possono contenere sostanze
inquinanti: rimuovere e adare tali componenti a ditte
specializzate nel recupero dei riuti, come indicato nella
direttiva 2012/19/UE. Vietato gettare nei riuti materiali nocivi
per l’ambiente.
GRAZIE
Vi ringraziamo per aver deciso di acquistare un prodotto Fadini.
Vi invitiamo a leggere attentamente queste istruzioni prima di
iniziare a usare il dispositivo. Le istruzioni contengono
informazioni importanti che vi aiuteranno a trarre il meglio da
questo dispositivo e vi garantiranno altresì sicurezza in fase di
installazione, uso e manutenzione del dispositivo. Conservare
questo manuale in un luogo pratico, in modo da poterlo
sempre consultare e garantire un utilizzo sicuro e adeguato del
dispositivo.
INTRODUZIONE
Questa automazione è stata progettata per un utilizzo
esclusivo per quanto indicato in questo libretto, con gli
accessori di sicurezza e di segnalazione minimi richiesti e con i
dispositivi Fadini. Qualsiasi altra applicazione non
espressamente indicata in questo libretto potrebbe provocare
disservizi o danni a cose e persone. Meccanica Fadini S.r.l. non
è responsabile per eventuali danni derivati da usi impropri e
non specicatamente indicati in questo libretto; non risponde
inoltre di malfunzionamenti derivati dall'uso di materiali e/o
accessori non indicati dalla ditta stessa. La ditta costruttrice si
riserva di apportare modiche ai propri prodotti senza
preavviso. Tutto quanto non espressamente indicato in
questo manuale di istruzioni non è permesso.
PRIMA DELL'INSTALLAZIONE
Prima di qualsiasi intervento valutare l'idoneità dell'ingresso da
automatizzare, nonché la sua condizione e la struttura.
Accertarsi che non si verichino situazioni di impatto,
schiacciamento, cesoiamento, convogliamento, taglio,
uncinamento e sollevamento, tali da poter pregiudicare la
sicurezza delle persone. Non installare il prodotto nelle
vicinanze di fonti di calore ed evitare il contatto con sostanze
inammabili. Tenere lontano dalla portata di bambini
qualsiasi dispositivo (trasmettitori, lettori di prossimità,
selettori, ecc.) atto ad avviare l'automazione. Il transito nella
zona di luce di passaggio deve avvenire unicamente con
l'automazione ferma. Non consentire a bambini e/o persone
di stazionare nei pressi dell'impianto con l'automazione in
movimento. Per garantire un livello adeguato di sicurezza
dell'impianto è necessario utilizzare fotocellule, bordi sensibili,
spire magnetiche e sensori di presenza per mettere in sicurezza
l'intera area interessata al movimento del cancello. Servirsi di
strisce giallo-nere o di adeguati segnali per identicare i punti
pericolosi dell'installazione. Togliere sempre l'alimentazione
elettrica all'impianto se si eettuano interventi di
manutenzione e/o pulizia. In caso di asportazione
dell’attuatore, non tagliare i li elettrici, ma toglierli dalla
morsettiera allentando le viti di serraggio dentro la scatola di
derivazione.
INSTALLAZIONE
L'intera installazione deve essere eettuata da personale
tecnico qualicato, in osservanza della Direttiva Macchine
2006/42/CE e in particolare le norme EN 12445 ed EN 12453.
Vericare la presenza, a monte dell'impianto, di un interruttore
di linea 230 V - 50 Hz magneto-termico dierenziale da 0,03 A.
Utilizzare corpi di prova idonei per le prove di funzionamento
nella rilevazione della presenza, in prossimità o interposti, ai
dispositivi di sicurezza come fotocellule, bordi sensibili, ecc.
Eseguire una attenta analisi dei rischi, utilizzando appositi
strumenti di rilevazione di impatto e schiacciamento del bordo
principale di apertura e chiusura, secondo quanto indicato
nella normativa EN 12445. Individuare la soluzione più
indicata per eliminare o ridurre tali rischi. Nel caso in cui il
cancello da automatizzare fosse dotato di un ingresso
pedonale, è opportuno predisporre l'impianto in maniera tale
da interdire il funzionamento del motore quando l'ingresso
pedonale è utilizzato. Fornire indicazioni sulla presenza
dell'impianto realizzato con l'applicazione di targhe
segnaletiche con marcatura CE sul cancello. L'installatore è
tenuto ad informare ed istruire l'utilizzatore nale circa l'uso
corretto dell'impianto; ciò avviene rilasciandogli una
documentazione rmata denita fascicolo tecnico,
IT
3
58
56
1 4 5 678910
ELPRO S20
T2
TEMPO DI PAUSA
1 s - 180 s
T1
TEMPO DI LAVORO
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9 L10 L11L5
ON
OFF
14567823 9101112
INNESTO PER SEMAFORO
A 3 LAMPADE MAX 100 W
PER LAMPADA
USCITA 24 Vdc
DIP-SWITCH
Elpro S20
Ingresso P
Fusibile
Secondario
Trasformatore
F4 = 2 A
Fusibile elettrovalvola, cicalino,
lampeggiatore e led F5 = 2 A
Fusibile motore M2
F2 = 1 A
Fusibile motore M1
F1 = 1 A
SUPPORTO PER
SCHEDA RADIO
AD INNESTO
Fusibile
primario
trasformatore
F3 = 630 mA
20 VA - 50/60 Hz
TRASFORMATORE
Filtro antidisturbi
+-
51 52 53
-
+
-
+
CICALINO
LED DI SEGNALAZIONE
230 V - 100 W max
COMUNE
16
17 18 51 52 53
55
56 70 71 72 51 52 53
COMUNE
M1
42
43
positivo +24 Vdc
negativo 0 Vdc
11 12 14 15
41
73 74 75
F=20 A
19
20 21
COMUNE
M2
F=20 A
24 25
Condensatore
con disgiuntore
elettronico
di spunto
M1 40 μF
71 72
70
nero
Condensatore
con disgiuntore
elettronico
di spunto
M2 40 μF
74 75
73
nero
Condensatore
Motore 1
40 μF
72
71
Condensatore
Motore 1
40 μF
72
71
Condensatore
Motore 2
40 μF
75
74
Condensatore
Motore 2
40 μF
75
74
Teleruttore
DISCESA
M1
Teleruttore
SALITA
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 84 25 84 17
18
16 16
70 71
7270
Teleruttore
SALITA
M2
Teleruttore
DISCESA
M2
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 94
25
94 21 20
19
1973 75 7473
12 Vac/dc
24 Vac/dc
L3
654 3 2 1 56 55
Relè di
Apertura 2
Relè di
Chiusura 2
Relè di
Apertura 1
Relè di
Chiusura 1
L1L2
L4
L5
654 321
comune
Fc.A. 2
NC
NA
comune
Fc.C. 2
NC
NA
comune
Fc.A. 1
NC
NA
comune
Fc.C. 1
NC
NA
A2
A1
3
2
1
6
5
4
9
8
750
56
55
7
4
6
7
4
56 5515 1412 11
11 1363 55 14 1364 55
55 5 55 1 55 42 55
43
55 45 55 50 13 12 13 15
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8
+ - I1 I2 I3 I4 I5 I6 IB IC ID IE IF IG - -
55 56 63 64 1 5
40
41 44
1
2
CN1
7
8
6
5
4
3
2
1
27 55 56 23 22
22 23
26
14 15
14 15
FINECORSA APERTURA TALOS 2
FINECORSA CHIUSURA TALOS 2
11 12
11 12
FINECORSA APERTURA TALOS 1
FINECORSA CHIUSURA TALOS 1
910
910
USCITA 24 V - 250 mA
per carico max:
- n° 2 coppie di fotocellule
- n° 1 radio ricevente
78
78
56
56
CHIUDE
STOP
RADIO
SPIA 24 V - 3 W max
34
34
COMUNE
APRE
55 56
+-
44
451
1
PEDONALE TALOS 1
FOTOCELLULE O
SPIRA MAGNETICA
42
43
40 41 44 45
ELETTROVALVOLA 1-3 TALOS 1
EFO
PRESSOSTATO TALOS 1
ELETTROVALVOLA 2 TALOS 1
42
42
ELETTROVALVOLA 1-3 TALOS 2
PRESSOSTATO TALOS 2
ELETTROVALVOLA 2 TALOS 2
24 25
ALIMENTAZIONE
QUADRO 400 V ± 10%
50 Hz TRIFASE
L1 N
84
L2
94
L3
ALIMENTAZIONE
QUADRO 230 V ± 10%
50 Hz MONOFASE
LNL L
!PONTICELLARE
L-L-L
58
40 58
27
26
+
-
13 16 17 18 19 20 21
FINECORSA EFO CONTROLLER MOTORI AUX
COMANDI E SICUREZZE 24 Vdc
ALIMENTAZIONE
ACCESSORI
Batterie
Elpro S50-T2.EFO
!Eseguire i collegamenti elettrici
solo su questa morsettiera ALIMENTAZIONE
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50.EFO
IMPORTANTE:
- Il programmatore deve essere installato in un luogo protetto e asciutto.
- Applicare un interruttore magneto-termico dierenziale del tipo 0,03 A ad alta sensibilità all’alimentazione del programmatore.
- Utilizzare un cavo multipolare tipo BUT FLESSIBILE FG 70R 12x1,5 mm², no ad una distanza massima di 20 m tra TALOS M50.EFO
ed ELPRO S50-T2.EFO.
- Per distanze superiori a 20 metri utilizzare li di sezione idonea alla buona regola di installazione.
- Per gli accessori di comando e sicurezza utilizzare cavi da 1 mm².
N.B: per applicazioni quali accensione luci, telecamere, ecc. utilizzare relè statici per non creare disturbi al microprocessore.
NEL CASO DI MANCATO FUNZIONAMENTO
- Accertarsi che l’alimentazione al programmatore elettronico sia 230 V ± 10% - 50 Hz
- Accertarsi che l’alimentazione al motore elettrico sia 230 V ± 10% - 50 Hz
- Per distanze superiori ai 20 metri aumentare la sezione dei li
- Controllare la tensione di alimentazione 230 V monofase
- Controllare i fusibili
- Controllare tutti i contatti chiusi del programmatore
- Controllare che non ci sia una caduta di tensione tra programmatore e motore elettrico
Simbologia
Contatto NA
Contatto NC
Led acceso
Led spento
Spia o lampada
Lampeggiatore
Fotocellule
o spire magnetiche:
1
DIP-SWITCH N° 1:
ON: Fotocellula ferma in apertura ed inverte
in chiusura a ostacolo rimosso
OFF: Fotocellula non ferma in apertura ed inverte
in chiusura in presenza di ostacolo
11
DIP-SWITCH N° 11:
ON: Durante la pausa in automatico
(Dip-Switch 3 = ON) al passaggio davanti le
fotocellule chiude dopo 5 s
OFF: Non chiude al passaggio davanti le fotocellule
Contatto per fotocellule
o spire magnetiche
Uscita 24 Vac - 250 mA
per carico max:
- n° 2 coppie di fotocellule
- n° 1 radio ricevente
Alimentazione quadro:
L2 acceso = nessun ostacolo presente, si spegne
ad ostacolo presente
IT
4
Accessorio Collegamenti elettrici Dip-switch e segnalazione LED delle varie funzioni
ALIMENTAZIONE
QUADRO 400 V ± 10%
50 Hz TRIFASE
L1 NL2 L3
ALIMENTAZIONE
QUADRO 230 V ± 10%
50 Hz MONOFASE
LNL L
!PONTICELLARE
L-L-L
Pedonale:
COMUNE
CONTATTO
PEDONALE
ON: chiude in automatico
OFF: non chiude in automatico.
Funzione semiautomatico
DIP-SWITCH N° 3 e N° 6 entrambi in ON:
ON: apertura pedonale motore M1
OFF: funzionamento normale
T2
TEMPO
DI PAUSA
1 s - 180 s
-
+
Con un comando pedonale si abbassa solo il
dissuasore collegato su M1.
La funzione apertura pedonale non è attiva
durante il primo ciclo di funzionamento
successivo ad una mancanza di tensione.
Elpro S50-T2.EFO
Attenzione: ogni volta che viene ripristinata l’alimentazione a Elpro S50-T2.EFO, si devono attendere 10 secondi perchè la logica del programmatore torni a funzionare
regolarmente.
LED DI DIAGNOSTICA
L1 = apre pedonale, normalmente spento, si illumina a comando apre pedonale
L2 = fotocellule o spira, normalmente acceso, si spegne con ostacolo presente
L3 = apre, normalmente spento, si illumina ad impulso apre
L4 = chiude, normalmente spento, si illumina ad impulso chiude
L5 = blocco, normalmente acceso, si spegne ad impulso di blocco
L6 = radio, normalmente spento, si illumina ad impulso radio
L7 = normalmente acceso, tensione di rete e integrità fusibili F1, F2, F3, F4
L8 = necorsa apertura M1, normalmente acceso, spento a colonna abbassata
L9 = necorsa chiusura M1, normalmente acceso, spento a colonna alzata
L10 = necorsa apertura M2, normalmente acceso, spento a colonna abbassata
L11 = necorsa chiusura M2, normalmente acceso, spento a colonna alzata
DIP-SWITCH
1 = ON Fotocellula o spira ferma in apertura
2 = ON Radio non inverte in apertura
3 = ON Chiude in automatico
4 = ON Prelampeggio lampeggiatore attivo
5 = ON Radio passo-passo con blocco intermedio
6 = ON Servizio un solo dissuasore pedonale motore M1
7 = ON Servizio a uomo presente
8 = Gestione semaforo (vedere riquadro delle funzioni)
9 = Gestione semaforo (vedere riquadro delle funzioni)
10 = ON Lampeggiatore spento in pausa
11 = ON Richiude in pausa dopo passaggio fotocellule o spira
12 = ON Tempo di lavoro massimo 90 s. OFF = 18 s
123456789101112
ON
OFF
31910
358 3
6
M1 M2
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50.EFO
4
DIP-SWITCH N° 4:
ON: Prelampeggio con cicalino
OFF: Senza prelampeggio con cicalino
10
DIP-SWITCH N° 10:
ON: Lampeggio e/o cicalino disattivato
durante la pausa in automatico
OFF: Lampeggio e/o cicalino attivato
durante la pausa in automatico
È possibile collegare oltre ai led integrati nel
dissuasore anche un lampeggiatore esterno.
Questo funzionerà durante il movimento di
salita e discesa e durante la pausa (se
impostata).
230 V - 100 W max
Selettore a chiave:
12
DIP-SWITCH N° 12:
ON: Tempo di lavoro massimo 90 s
OFF: Tempo di lavoro massimo 18 s
Contatti NA e NC da collegare ai rispettivi
morsetti dei selettori o pulsantiere.
Tutte le possibili congurazioni sono allegate
ai rispettivi accessori di comando.
Spia accesa = colonna abbassata, passaggio libero
Spia spenta = colonna alzata, passaggio chiuso
Lampeggia a 0,5 s (veloce) = movimento di salita
Lampeggia a 1 s (normale) = movimento di discesa
Con orologio esterno: 2 brevi lampeggi seguiti da
una pausa più lunga
Spia 24 V - 3 W max
di segnalazione
del movimento:
Motori:
Finecorsa:
T2
TEMPO DI PAUSA
1 s - 180 s
T1
TEMPO DI LAVORO
1 s - 22 s
-
+
-
+
Led di segnalazione:
Uscita per led a luce intermittente sempre
funzionanti durante il movimento di salita e
discesa e nella sosta a colonna alzata.
Si spengono a colonna abbassata.
Il dispositivo sonoro è all’interno della
colonna a scomparsa e attivo solo durante il
movimento di salita e discesa.
Cicalino di movimento
e/o lampeggiante:
L3 spento = nessun contatto apre, si accende ad
ogni impulso di apertura
L4 spento = nessun contatto chiude, si accende
ad ogni impulso di chiusura
L5 acceso = contatto di stop chiuso, si spegne ad
ogni impulso di stop
L8 acceso = si spegne a colonna 1 abbassata
L9 acceso = si spegne a colonna 1 alzata
MOTORE 1
dissuasore 1
16 17 18
M1
COMUNE
COMUNE LED
E/O CICALINO
LED
MOTORE 2
dissuasore 2
19 20 21
COMUNE
M2
L10 acceso = si spegne a colonna 2 abbassata
L11 acceso = si spegne a colonna 2 alzata
COMUNE LED
E/O CICALINO
CICALINO
E/O LAMPEGGIANTE
IT
5
Accessorio Collegamenti elettrici Dip-switch e segnalazione LED delle varie funzioni
Contatto radio:
2
DIP-SWITCH N° 2:
ON: Non inverte in apertura
OFF: Inverte la marcia ad ogni impulso
5
DIP-SWITCH N° 5:
ON: Passo passo con blocco intermedio
OFF: Funzionamento normale
Collegando un qualsiasi contatto NA tra i due
morsetti si può ottenere ad ogni impulso:
- Solo apertura: Dip 2 = ON e Dip 5 = OFF
- Inversione di marcia ad ogni impulso
Dip 2 = OFF e Dip 5 = OFF
- Passo passo: apre - stop - chiude - stop
Dip 2 = OFF e Dip 5 = ON
- In fase di apertura non accetta nessun
comando. In pausa e in chiusura ad ogni
comando esegue lo stop con inversione di
marcia: Dip 2 = ON e Dip 5 = ON L7 spento = nessun contatto RADIO, si accende
ad ogni impulso del contatto radio
F=20A
F=20A
Elpro S50-T2.EFO
CHIUDE
STOP
COMUNE
APRE
NC
5634
CONTATTO RADIO
RADIO
COMUNECOMUNE
73
83
necorsa chiusura
TALOS 1
necorsa apertura
TALOS 1
necorsa apertura
TALOS 2
necorsa chiusura
TALOS 2
12
14
15
11
positivo +24 Vdc
negativo 0 Vdc
55 56
+-
51 52 53
51 52 53
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50.EFO
Descrizione Dip-switch e segnalazione LED delle varie funzioni
3
DIP-SWITCH N° 3:
ON: Chiude in automatico
OFF: Non chiude in automatico.
Funzione semiautomatico
T2
TEMPO DI PAUSA
1 s - 180 s
-
+
FUNZIONI
7
DIP-SWITCH N° 7:
ON: Funzionamento a uomo presente
OFF: Funzionamento normale
Uomo presente:
Si ottiene il comando di apertura e chiusura “ad azione mantenuta”
(senza autotenuta nei relè). È richiesta l’attiva presenza dell’operatore
durante tutto il movimento dell’automazione no al rilascio del pulsante
o della chiave del selettore.
Automatico / semiautomatico:
Ciclo automatico: ad un impulso di comando apre, la colonna si abbassa, si ferma in pausa per il tempo
impostato sul trimmer T2, scaduto il quale risale automaticamente.
Ciclo semiautomatico: ad un impulso di comando apre la colonna si abbassa. Per chiudere il passaggio
bisogna dare l’impulso di chiusura.
3
DIP-SWITCH N° 3:
ON: Chiude in automatico
OFF: Non chiude in automatico.
Funzione semiautomatico
T2
TEMPO DI PAUSA
1 s - 180 s
-
+
Orologio esterno (optional):
OROLOGIO: il programmatore Elpro S50-T2.EFO consente il collegamento di un normale orologio per la
salita e la discesa del dissuasore.
Collegamento: collegare in parallelo il contatto NA dell’orologio con il morsetto n° 4 apre e n° 3 comune,
attivando la richiusura automatica con il Dip-Switch n° 3 = ON.
Funzionamento: programmare l’orario di apertura sull’orologio, all’ora impostata il dissuasore si abbassa e
la spia segnala con 2 brevi lampeggi seguiti da una pausa più lunga), e non accetterà più nessun comando
(anche radio) sino allo scadere del tempo impostato sull’orologio, allo scadere del quale dopo il tempo di
pausa seguirà la salita automatica.
DIP-SWITCH N° 8 e N° 9:
Schedina semaforo ad innesto (optional):
L’alimentazione della schedina è indipendente da quella
della scheda del programmatore:
- 230 V - 50 Hz con uscita di 100 W a 230 V per lampada.
- 24 V con uscita di 25 W per lampada.
- 12 V con uscita di 22 W per lampada.
Funzionamento anche per semaforo a 2 lampade rosso
e verde (Dip Switch 8 = OFF e 9 = OFF).
Logica di Funzionamento:
- Luce VERDE = colonna abbassata, passaggio APERTO
- Luce ROSSA = colonna in movimento o alzata,
passaggio CHIUSO
- Luce GIALLA = interviene prima del passaggio da
luce verde a luce rossa.
Nota: In funzionamento pedonale il semaforo rimane
sempre ROSSO.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF e 9 = OFF
Si accende il giallo per tempo 0 s e
dopo 0 s si accende il rosso e si alza
la colonna immediatamente.
Dip-Switch 8 = ON e 9 = OFF
Si accende il giallo per tempo 2 s,
poi si accende il rosso e dopo 2 s si
alza la colonna.
Dip-Switch 8 = OFF e 9 = ON
Si accende il giallo per tempo 6 s,
poi si accende il rosso e dopo 5 s si
alza la colonna.
Dip-Switch 8 = ON e 9 = ON
Si accende il giallo per tempo 10 s,
poi si accende il rosso e dopo 7 s si
alza la colonna.
ROSSO
GIALLO
VERDE
Rossa
Gialla
Verde
Fusibile 1 A
(Optional: schedina semaforo
ad innesto per lampade a 230 V,
24 V o 12 V).
Codice 7282L
Rosso
Giallo
Verde
Alimentazione
230 V - 50 Hz,
24 V o 12 V
Comune
63 64 65 66 60 61
IT
6
EFO: Emergency Fast Operation
Il dispositivo di emergenza EFO permette la risalita rapida del dissuasore in poco più di 1,5 secondi, garantendo la massima protezione in situazioni di estrema necessità
e pericolo. Essendo un dispositivo di emergenza, va utilizzato solo in caso di reale esigenza; la sua attivazione disattiva infatti tutti i dispositivi di sicurezza presenti ed
installati, provocando potenzialmente danni a persone e cose nelle immediate vicinanze del dissuasore.
Meccanica Fadini non si assume nessuna responsabilità sull’uso non appropriato di tale dispositivo e sui possibili danni provocati a persone e a cose durante il suo
utilizzo. L’attivazione dell’EFO avviene tramite un pulsante di emergenza (non in dotazione) ed in mancanza di corrente il suo funzionamento, risalita del dissuasore a
velocità superiore a quella standard, è garantito per un breve periodo (circa unora). Una volta attivato, il dispositivo EFO si riarma autonomamente per un’eventuale
successiva attivazione (non è necessario un intervento esterno da parte di un operatore). Si precisa che, quando il dissuasore raggiunge la posizione dissuasiva (colonna
alzata), la centralina idraulica continua a funzionare per qualche secondo: è unoperazione corretta in quanto, in questo frangente, è in corso il riarmo del dispositivo.
Elpro S50-T2.EFO
CONTATTO
DI EMERGENZA
EFO
COMUNE
EFO
340
ELETTROVALVOLA 1-3
TALOS 1
PRESSOSTATO
TALOS 1
ELETTROVALVOLA 2
TALOS 1
ELETTROVALVOLA 1-3
TALOS 2
PRESSOSTATO
TALOS 2
ELETTROVALVOLA 2
TALOS 2
42
43
44
4542
41
positivo +24 Vdc
negativo 0 Vdc
55 56
+-
Collegamenti elettrici EFO
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50.EFO
GENERAL WARNINGS FOR PEOPLE SAFETY
THANK YOU
Thank you for purchasing a Fadini product.
Please read these instructions carefully before using this
appliance. The instructions contain important information
which will help you get the best out of the appliance and
ensure safe and proper installation, use and maintenance.
Keep this manual in a convenient place so that you can always
refer to it for the safe and proper use of the appliance.
INTRODUCTION
This operator is designed for a specic scope of applications as
indicated in this manual, including safety, control and signaling
accessories as minimum required with Fadini equipment. Any
applications not explicitly included in this manual may cause
operation problems or damages to properties and people.
Meccanica Fadini S.r.l. is not liable for damages caused by the
incorrect use of the equipment, or for applications not included
in this manual or for malfunctioning resulting from the use of
materials or accessories not recommended by the
manufacturer. The manufacturer reserves the right to make
changes to its products without prior notice. All that is not
explicitly indicated in this manual is to be considered not
allowed.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability
of the access, its general condition and the structure. Make
sure that there is no risk of impact, crushing, shearing,
conveying, cutting, entangling and lifting situations, which
may prejudice people safety. Do not install near any source of
heat and avoid contacts with ammable substances. Keep all
the accessories able to turn on the operator (transmitters,
proximity readers, key-switches, etc) out of the reach of the
children. Transit through the access only with stationary
operator. Do not allow children and/or people to stand in the
proximity of a working operator. To ensure safety in the
whole movement area of a gate it is advisable to install
photocells, sensitive edges, magnetic loops and detectors.
Use yellow-black strips or proper signals to identify dangerous
spots. Before cleaning and maintenance operations,
disconnect the appliance from the mains by switching o the
master switch. If removing the actuator, do not cut the
electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied
technician, in observance of the Machinery Directive
2006/42/CE and safety regulations EN 12453 - EN 12445.
Verify the presence of a thermal-magnetic circuit breaker 0,03
A - 230 V - 50 Hz upstream the installation. Use appropriate
objects to test the correct functionality of the safety
accessories, such as photocells, sensitive edges, etc. Carry out
a risk analysis by means of appropriate instruments measuring
the crushing and impact force of the main opening and closing
edge in compliance with EN 12445. Identify the appropriate
solution necessary to eliminate and reduce such risks. In case
where the gate to automate is equipped with a pedestrian
entrance, it is appropriate to prepare the system in such a way
to prohibit the operation of the engine when the pedestrian
entrance is used. Apply safety nameplates with CE marking
on the gate warning about the presence of an automated
installation. The installer must inform and instruct the end
user about the proper use of the system by releasing him a
technical dossier, including: layout and components of the
installation, risk analysis, verication of safety accessories,
verication of impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive
information concerning only the operation of the installation
so that he becomes himself responsible for the correct use of it.
The end-user shall establish a written maintenance contract
with the installer/maintenance technician (on -call). Any
maintenance operation must be done by qualied technicians.
Keep these instructions carefully.
WARNINGS FOR THE CORRECT OPERATION OF THE
INSTALLATION
For optimum performance of system over time according to
safety regulations, it is necessary to perform proper
maintenance and monitoring of the entire installation: the
automation, the electronic equipment and the cables
connected to these. The entire installation must be carried
out by qualied technical personnel, lling in the Maintenance
Manual indicated in the Safety Regulation Book (to be
requested or downloaded from the site
www.fadini.net/supporto/downloads).
Operator: maintenance inspection at least every 6 months,
while for the electronic equipment and safety systems an
inspection at least once every month is required. The
manufacturer, Meccanica Fadini S.r.l., is not responsible for
non-observance of good installation practice and incorrect
maintenance of the installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as
cardboard, nylon, polystyrene etc. through specializing
companies (after verication of the regulations in force at the
place of installation in the eld of waste disposal). Disposal of
electrical and electronic materials: to remove and dispose
through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is
prohibited.
UE DECLARATION OF CONFORMITY (DoC)
Manufacturer: Meccanica Fadini S.r.l.
Address: Via Mantova, 177/A - 37053 Cerea - VR - Italy
declare that the DoC is issued under our sole responsibility and
belongs to the following product:
Control unit model ELPRO S50-T2.EFO
is in conformity with the relevant Union harmonisation legislation:
- Electromagnetic Compatibility Directive 2014/30/UE
- Low Voltage Directive 2014/35/UE
Cerea, 13/10/2017 Meccanica Fadini S.r.l.
Responsible Manager
GB CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
7
Elpro S50-T2.EFO
GB CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
8
Elpro S50-T2.EFO
58
56
1 4 5 678910
ELPRO S20
T2
DWELL TIME
1 s - 180 s
T1
MOTOR RUN TIME
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9 L10 L11L5
ON
OFF
14567823 9101112
CONNECTOR FOR TRAFFIC
LIGHT WITH 3 LAMPS
MAX 100 W EACH LAMP
24 Vdc OUTPUT
DIP-SWITCH
Elpro S20
Input P
Transformer
secondary
fuse
F4 = 2 A
Fuse for solenoid valve, beeper,
asher and LEDs F5 = 2 A
M2 motor fuse
F2 = 1 A
M1 motor fuse
F1 = 1 A
PLUG-IN
RADIO CARD
CONNECTOR
Transformer
primary
fuse
F3 = 630 mA
20 VA - 50/60 Hz
TRANSFORMER
Anti-disturbance lter
+-
51 52 53
-
+
-
+
BEEPER
SIGNALLING LEDs
230 V - 100 W max
COMMON
16
17 18 51 52 53
55
56 70 71 72 51 52 53
COMMON
M1
42
43
positive +24 Vdc
negative 0 Vdc
11 12 14 15
41
73 74 75
F=20 A
19
20 21
COMMON
M2
F=20 A
24 25
Electronic
circuit breaker
with capacitor
M1
40 μF
71 72
70
black
Electronic
circuit breaker
with capacitor
M2
40 μF
74 75
73
black
Motor 1
Capacitor
40 μF
7271
Motor 1
Capacitor
40 μF
7271
Motor 2
Capacitor
40 μF
7574
Motor 2
Capacitor
40 μF
7574
Contactor
LOWERING
M1
Contactor
RISING
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 84 25 84 17
18
16 16
70 71
7270
Contactor
RISING
M2
Contactor
LOWERING
M2
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 94
25
94 21 20
19
1973 75 7473
12 Vac/dc
24 Vac/dc
L3
654 3 2 1 56 55
Opening
Relay 2
Closing
Relay 2
Opening
Relay 1
Closing
Relay 1
L1L2
L4
L5
654 321
common
L-sw.O. 2
NC
NO
common
L-sw.C. 2
NC
NO
common
L-sw.O. 1
NC
NO
common
L-sw.C. 1
NC
NO
A2
A1
3
2
1
6
5
4
9
8
750
56
55
7
4
6
7
4
56 5515 1412 11
11 1363 55 14 1364 55
55 5 55 1 55 42 55
43
55 45 55 50 13 12 13 15
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8
+ - I1 I2 I3 I4 I5 I6 IB IC ID IE IF IG - -
55 56 63 64 1 5
40
41 44
1
2
CN1
7
8
6
5
4
3
2
1
27 55 56 23 22
22 23
26
14 15
14 15
LIMIT SWITCH OPENING TALOS 2
LIMIT SWITCH CLOSING TALOS 2
11 12
11 12
LIMIT SWITCH OPENING TALOS 1
LIMIT SWITCH CLOSING TALOS 1
910
910
24 V - 250 mA Output.
Max load:
- n° 2 pairs photocells
- n° 1 radio receiver
78
78
56
56
CLOSE
STOP
RADIO
LIGHT 24 V - 3 W max
34
34
COMMON
OPEN
55 56
+-
44
451
1
PEDESTRIANS TALOS 1
PHOTOCELLS OR
MAGNETIC LOOP
42
43
40 41 44 45
SOLENOID VALVE 1-3 TALOS 1
EFO
PRESSURE SWITCH TALOS 1
SOLENOID VALVE 2 TALOS 1
42
42
SOLENOID VALVE 1-3 TALOS 2
PRESSURE SWITCH TALOS 2
SOLENOID VALVE 2 TALOS 2
24 25
BOARD POWER
SUPPLY 400 V ± 10%
50 Hz THREE-PHASE
L1 N
84
L2
94
L3
BOARD POWER
SUPPLY 230 V ± 10%
50 Hz SINGLE-PHASE
LNL L
!JUMPER
L-L-L
58
40 58
+
-
13 16 17 18 19 20 21
LIMIT SWITCH EFO CONTROLLER MOTORS AUX
POWER SUPPLY
CONTROLS AND SAFETY 24 Vdc
POWER SUPPLY
OF ACCESSORIES
Batteries
!Make the electrical connections
only on this terminal block
27
26
GB CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
9
Elpro S50-T2.EFO
NOTE WELL:
- The control panel must be installed in a sheltered, dry place.
- Fit the mains to the control panel with a 0,03 A high sensitivity magneto-thermal circuit breaker.
- Use a multipole cable type BUT FLESSIBILE FG 70R 12x1,5 mm², up to a recommended distance of 20 m maximum between TALOS M50.EFO
and ELPRO S50-T2.EFO.
- For distances longer than 20 m use cables having an adequate section in compliance with the rules of good installation praxis.
- Use 1 mm² section wires for command and safety accessories.
N.W: To t extra accessories such as lights, CCTV etc. use only solid state relays to prevent interference with the microprocessor.
IN CASE OF FAILURE OF THE CONTROL BOARD:
- Make sure voltage supply to the electronic board is 230 V ±10% - 50 Hz
- Make sure voltage supply to the electric motor is 230 V ±10% - 50 Hz
- For distances beyond 20 meters increase wire section
- Check power supply 230 V single-phase
- Check fuses
- Check all NC contacts of the control board
- Check that no voltage drop has occurred from the control board to the electric motor
Symbols
NO Contact
NC Contact
Led ON
Led OFF
Indication light
or lamp
Flasher
Photocells
or loop detectors:
Photocells or
loop detectors
24 Vac - 250 mA Output
max load:
- n° 2 pairs of photocells
- n° 1 radio receiver
Board power supply:
Accessory Electrical connections Dip-switches and LED status of the various functions
L1 NL2 L3
BOARD POWER SUPPLY
230 V ± 10%
50 Hz SINGLE-PHASE
BOARD POWER SUPPLY
400 V ± 10%
50 Hz THREE-PHASE
LNL L
!JUMPER
L-L-L
Pedestrian opening:
COMMON
PEDESTRIAN
OPENING
CONTACT
ON: automatic closing
OFF: No automatic closing.
Semi-automatic closing
DIP-SWITCH N° 3 and N° 6 both on ON:
3
ON: pedestrian opening motor M1
OFF: standard operation
6
T2
DWELL
TIME
from 1 to 180 s
-
+
By a pedestrian command only the bollard
connected to M1 is lowered. The pedestrian
opening function cannot be performed
during the rst operating cycle after a power
failure.
Note well: whenever Elpro S50-T2.EFO is re-powered, wait 10 seconds for the logic to become fully operating again.
DIAGNOSTIC LEDS
L1 = pedestrian opening, normally OFF, alight when a pedestrian open pulse is given
L2 = photocells or loop, normally ALIGHT, if obstructed light goes o
L3 = open, normally OFF, alight when an open pulse is given
L4 = close, normally OFF, alight when a close pulse is given
L5 = stop, normally ON, it goes o when a stop pulse is given
L6 = radio, normally OFF, alight when a radio pulse is given
L7 = normally ON, mains voltage and fuse integrity F1, F2, F3, F4
L8 = limit switch open M1, normally ON, it goes o when the post is in down position
L9 = limit switch close M1, normally ON, it goes o when the post is in up position
L10 = limit switch open M2, normally ON, it goes o when the post is in down position
L11 = limit switch close M2, normally ON, it goes o when the post is in up position
DIP-SWITCHES
1 = ON Photocells or loop stop while opening
2 = ON Radio no reversing while opening
3 = ON Automatic closing
4 = ON Pre ashing activated
5 = ON Radio step by step stop in between
6 = ON Pedestrian opening motor M1 only one post operating
7 = ON Deadman control
8 = Trac lights (see functions)
9 = Trac lights (see functions)
10 = ON No lamp on during dwell time
11 = ON Close on dwell time after passage through photocells or over the loop
12 = ON Max working time 90 s. OFF = 18 s
123456789101112
ON
OFF
31910
358
1
DIP-SWITCH N° 1:
ON: Photocells. Stop while opening,
reverse in closing once obstacle is removed
OFF: Photocells. No stop while opening, reverse
in closing in case of an obstacle
11
DIP-SWITCH N° 11:
ON: During dwell time, automatic mode,
(Dip-Switch 3 = ON) after engaging the
photocells, it closes after 5 s
OFF: no closing after engaging the photocells
L2 ON = no obstruction. It goes o in case of an
obstacle
M1 M2
2
DIP-SWITCH N° 2:
ON: No reversing in opening
OFF: Travel reversing on each pulse
5
DIP-SWITCH N° 5:
ON: Step by step mode with stop in between
OFF: Standard functioning
L7 OFF = no RADIO contact, it goes on henever
a radio pulse is given
GB CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
10
Elpro S50-T2.EFO
It is possible to connect an external ashing
lamp to the bollard in addition to the
incorporated LED lights. The asher will be
on during the rising and lowering
movements and during the dwell time (if
pre-selected).
230 V - 100 W max
Key-switch:
12
DIP-SWITCH N° 12:
ON: Motor run time max 90 s
OFF: Motor run time max 18 s
NO and NC contacts to be connected to the
respective terminals of the key-switches or
push-buttons.
All possible congurations are described in
the instructions attached to the respective
control accessory
Light on = post down, gateway cleared
Light o = post up, gateway closed
Flashing 0,5 s (fast) = post moving up
Flashing 1 s (normal) = post moving down
With an external time clock: 2 short ashes
followed by a longer pause
24 V - 3 W max
Light indicating
bollard in motion:
Motors:
Limit switches:
T2
DWELL TIME
1 s - 180 s
T1
MOTOR RUN TIME
1 s - 22 s
-
+
-
+
Signalling LED lights:
Output for the LED lights that are always on
blinking during the rising and lowering
movements of the post and with the post in
standing position. They go o with post in
down position.
The acoustic device is inside the post and is
on only during the rising and lowering
movements of the post.
Beeper, post in motion
and/or external asher:
L3 OFF = no contact to open, it goes on
whenever a pulse to open is given
L4 OFF = no contact to close, it goes on
whenever a pulse to close is given
L5 ON = stop contact closed, it goes o
whenever a pulse to stop is given
L8 ON = it goes o with post 1 down
L9 ON = it goes o with post 1 up
Bollard 1
MOTOR 1
16 17 18
M1
COMMON
LEDs AND/OR
BEEPER COMMON
LEDs
Bollard 2
MOTOR 2
19 20 21
COMMON
M2
L10 ON = it goes o with post 2 down
L11 ON = it goes o with post 2 up
BEEPER OR
LED. COMMON
BEEPER
AND/OR FLASHER
Accessory Electrical connections Dip-switches and LED status of the various functions
Radio contact: With any NO contact to the two terminals,
the following is performed on each pulse:
- Opening only: Dip 2 = ON and Dip 5 = OFF
- Travel reversing
Dip 2 = OFF and Dip 5 = OFF
- Step by step: open - stop - close - stop
Dip 2 = OFF and Dip 5 = ON
- No further command accepted on opening.
Stop and reversing performed on dwell time
and closing:
Dip 2 = ON and Dip 5 = ON
F=20A
F=20A
CLOSE
STOP
COMMON
OPEN
NC
5634
RADIO CONTACT
RADIO
COMMONCOMMON
73
83
limit switch
closing TALOS 1
limit switch
opening TALOS 1
limit switch
opening TALOS 2
limit switch
closing TALOS 2
12
14
15
11
positive +24 Vdc
negative 0 Vdc
55 56
+-
51 52 53
51 52 53
4
DIP-SWITCH N° 4:
ON: Pre-ashing with beeper
OFF: No pre-ashing with beeper
10
DIP-SWITCH N° 10:
ON: Flasher and/or beeper. Deactivated during
dwell time, automatic mode
OFF: Flasher and/or beeper. Activated during
dwell time, automatic mode
DIP-SWITCHES N° 8 and N° 9:
Plug-in trac lights card (optional):
The power supply of the trac lights card is independent
from that of the electronic control board:
- 230 V - 50 Hz with an output of 100 W at 230 V ea. lamp.
- 24 V with an output of 25 W each lamp.
- 12 V with an output of 22 W each lamp.
Functioning applies also to trac lights with 2 lamps, red
and green (Dip Switch 8 = OFF and 9 = OFF).
Functioning logic:
- GREEN Light= post down, gateway OPEN
- RED Light = post moving or standing,
gateway CLOSED
- YELLOW Light = it switches on before green turns
to red light.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF and 9 = OFF
Yellow turns on for 0 s and after 0 s
red turns on and the post starts
rising immediately
Dip-Switch 8 = ON and 9 = OFF
Yellow turns on for 2 s, then red
turns on and after 2 s the post
starts rising
Dip-Switch 8 = OFF and 9 = ON
Yellow turns on for 6 s, then red
turns on and after 5 s the post
starts rising
Dip-Switch 8 = ON and 9 = ON
Yellow turns on for 10 s, then red
turns on and after 7 s the post
starts rising
RED
YELLOW
GREEN
Red
Yellow
Green
Fuse 1 A
(Optional: plug-in trac lights
card at a 230 V, 24 V or 12 V).
Item Code No. 7282L
Red
Yellow
Green
Power supply
230 V - 50 Hz,
24 V or 12 V
Common
63 64 65 66 60 61
GB CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
11
Elpro S50-T2.EFO
Description Dip-switches and LED status of the various functions
3
DIP-SWITCH N° 3:
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic mode
T2
DWELL TIME
1 s - 180 s
-
+
FUNCTIONS
7
DIP-SWITCH N° 7:
ON: Deadman control
OFF: Standard operating mode
Deadman control:
Open and Close operations are achieved “by holding a switch on” (no
relay self-holding is involved). Therefore, a physical attendance is
required during the entire cycle of movements until either the button or
key is released.
Automatic / semiautomatic:
Automatic cycle: after a pulse to open, the bollard goes down, it stays stopped as long as the dwell
time lasts, as pre-set by T2 trimmer, and on expiring of such time it goes up automatically.
Semi-Automatic cycle: after a pulse to open, the bollard goes down.
Another pulse is needed to close the gateway.
3
DIP-SWITCH N° 3:
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic operating
mode
T2
DWELL TIME
1 s - 180 s
-
+
External time clock (optional):
CLOCK: the Elpro S50-T2.EFO controller allows for a normal clock to be connected to it commanding the
post to rise and lower.
Connections: parallel connect the NO contact of the clock to the terminals No. 4 open and No. 3 common,
and set the controller to automatic mode by Dip-Switch n° 3 = ON.
How it works: set the clock to the required opening time. On the pre-set time the post is automatically
lowered (the indication light emits 2 short ashes followed by a longer pause). Any further
command/pulsing (even by remote control) is not accepted by the system until the time pre-set on the
clock is expired. On expiring of it, and after the pre-set dwell time, the post rises automatically.
EFO: Emergency Fast Operation
EFO
EMERGENCY
CONTACT
COMMON
EFO
340
SOLENOID VALVE 1-3
TALOS 1
PRESSURE SWITCH
TALOS 1
SOLENOID VALVE 2
TALOS 1
SOLENOID VALVE 1-3
TALOS 2
PRESSURE SWITCH
TALOS 2
SOLENOID VALVE 2
TALOS 2
42
43
44
4542
41
positive +24 Vdc
negative 0 Vdc
55 56
+-
EFO electrical connections
The EFO emergency device allows for the bollard to rise quickly in no more than 1,5 seconds and ensures maximum protection in situations of extreme necessity and
danger. Being an emergency device, it should be used only in case of real need; in fact, when it is activated, all the safety devices present in the system and installed with
it are deactivated, potentially causing a situation where damage to people and things may occur in the immediate proximity of the bollard.
Meccanica Fadini does not take any responsibility for the improper use of this device and the possible damage caused to people and properties during the use of it. The
activation of EFO is by means of an emergency button (not supplied with the equipment) and in case of power failure its operation, ascent rate higher than the standard
one, is guaranteed for a short period (about an hour). Once activated, the EFO device is able to reset itself for a possible next activation (no external action of a physical
operator is required). It should be noted that, when the bollard reaches the deterrent position (cylinder fully raised), the hydraulic unit continues to work for a few
seconds: this is a correct operation as, in this circumstance, the device is resetting.
AVERTISSEMENTS DE SECURITE AUX USAGERS
NOUS VOUS REMERCIONS
Nous vous remercions d'avoir acheté un produit Fadini.
Veuillez lire attentivement ces instructions avant d’utiliser l'appareil.
Ces instructions sont des informations utiles vous permettant de
mieux exploiter cet appareil,et vous assurer une installation, une
utilisation et un entretien sécurisés et adéquats.
Veuillez bien garder ce manuel et toujours vous y référ pour une
utilisation sécurisée et adéquate de l'appareil.
INTRODUCTION
Cet automatisme a été conçu pour une utilisation qui respecte ce qu'il
y a indiqué dans ce livret, avec les accessoires de sécurité et de
signalisation minimaux demandés et avec les dispositifs Fadini.
Toute autre application pas expressément indiquée dans ce livret
pourrait provoquer des dysfonctionnements ou des dommages à
choses et personnes. Meccanica Fadini n'est pas responsable
d'éventuels dommages provoqués par une utilisation impropre et non
spéciquement indiquée dans ce livret. En outre, elle n'est pas
responsable des dysfonctionnements causés de l'usage de matériels
ou accessoires non recommandés par le fabricant. L'entreprise de
construction se réserve le droit d'apporter des modications aux
propres produits sans préavis. Tout ce qui n'est pas prévue dans
cette notice d'installation n'est pas permis.
INSTRUCTIONS A SUIVRE AVANT L'INSTALLATION
Contrôler avant toute intervention que l'entrée soit adapté à
l'automatisation, ainsi que ces conditions et structure. Assurez-vous
qu'y ne soit pas des risques d'impact, écrasement, cisaillement,
convoyage, entraînement et enlèvement, tells qu'on pourrait aecter
la sécurité des personnes. Installer l'automatisme loin de tout
sources de chaleur et éviter le contact avec substances inammables.
Garder tout dispositifs de contrôle automatisme (émetteurs,
lecteurs de proximité, sélecteurs etc) hors de la portée des enfants.
Transiter à travers la zone du mouvement du portail seulement
lorsque l'automatisme est fermé. An de garantir un niveau de
sécurité adéquat de l'installation il est nécessaire d'utiliser
photocellules, listeaux sensibles, spires magnétiques, détecteurs de
masse métalliques, en assurant la sécurité de tout l'aire de
mouvement du portail. Identier les points dangereux de
l'installation en l'en indiquant avec bandes jaune-noir ou autres
signaux appropriés. Couper l'alimentation avant toute intervention
d'entretien ou nettoyage de l'installation. Dans le cas on doit enlever
l’opérateur du portail, ne pas couper les ls électrique; mais les
débrancher en desserrant les vis du bornier.
L'INSTALLATION
Toute l'installation doit être accomplie par personnel technique
qualié et autorisé, conformément à la directive Machines 2006/42/CE
et, notamment, aux normes EN 12445 et EN 12453. Vérier la
présence en amont de l'installation d'un interrupteur diérentiel
magnétothermique de 0,03 A de courant 230 V - 50 Hz. Utiliser des
objets approprié pour eectuer les tests de fonctionnement des
photocellules, détecteurs des masses métalliques, listeaux sensibles,
etc. Eectuer une analyse des risques, en utilisant instruments de
détection de l'impact et écrasement du bord principale d’ouverture et
fermeture, conformément aux normes EN 12445. Dénir les
solutions appropriées pour éliminer ou réduire tels risques. Dans le
cas où le portail à automatiser aurait doué d'une entrée piétonne, il
serait bon d'accomplir l'installation de façon que le moteur ne
fonctionne pas lorsque l'entrée piéton est utilisé. Fournir des
indications concernant la position de l’installation en appliquant sur le
portail des plaquettes de signalisation marquée CE. L'installateur
doit informer l'utilisateur sur le fonctionnement correct du système,
en lui remettant le dossier technique signé, incluant: le schéma et les
éléments composants l'installation, l'analyse des risques, la
vérication des accessoires de sécurité, la vérication de la force
d'impact et la déclaration des risques résiduels.
INDICATIONS POUR L'UTILISATEUR FINAL
L'utilisateur doit consulter et recevoir information relative au
fonctionnement de l'installation et il devient lui-même responsable
du bon usage du système. Il faut qu'il conclue un contrat d'entretien
ordinaire et extraordinaire (sur appel) avec l'installateur/réparateur.
Toute l’intervention d'entretien doivent être accompli par des
techniciens qualiés. Conserver toujours la notice d'installation.
AVERTISSEMENTS POUR LE FONCTIONNEMENT CORRECT DE
L'INSTALLATION
Pour que l’installation fonctionne correctement de façon durable et
conformément aux normes de sécurité en vigueur, vous devez faire
eectuer un entretien correct et le monitorage de toute l’installation
au niveau de l’automation, des appareils électroniques installés et des
câblages qui y sont branchés. Toute l'installation doit être eectuée
par un technicien qualié, qui doit remplir le Manuel d'Entretien
indiqué dans le Livret des Normes (à demander ou télécharger sur le
site www.fadini.net/supporto/downloads). L'automation: contrôle
d'entretien tous les 6 mois au moins, tandis que le contrôle d'entretien
des appareils électroniques et systèmes de sécurité doit être accompli
une fois par mois au moins. Meccanica Fadini S.r.l. n'est pas
responsable de l'éventuel non-respect des règles de bonne technique
d'installation et/ou de l'entretien incorrect du système.
RAMASSAGE DES MATERIAUX
Les éléments d'emballage, tels que le carton, nylon, polystyrène, etc.
peuvent être recyclés avec le collecte séparé (en vériant la
réglementation en vigueur en la matière dans le pays où le dispositif
est monté). Les composants électriques et électroniques, les batteries
peuvent contenir des substances polluantes: enlever et coner tels
composants aux sociétés chargées du traitement et de l’élimination
des déchets, dans le respect de la directive 2012/19/UE. Ne pas jeter
déchets nuisibles à l'environnement.
Meccanica Fadini S.r.l.
Directeur Responsable
DECLARATION UE DE CONFORMITE
Fabricant: Meccanica Fadini S.r.l.
Adresse: Via Mantova, 177/A - 37053 Cerea - VR - Italy
déclare sous sa propre responsabilité que le produit:
Programmateur électronique modèle ELPRO S50-T2.EFO
il est conforme à la législation d'harmonisation de l'Union:
- Directive Compatibilité Electromagnétique 2014/30/UE
- Directive Basse Tension 2014/35/UE
Cerea, 13/10/2017
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50.EFO
FR
12
Elpro S50-T2.EFO
FR
13
Elpro S50-T2.EFO
58
56
1 4 5 678910
ELPRO S20
T2
TEMPS DE PAUSE
1 s - 180 s
T1
TEMPS DE TRAVAIL
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9 L10 L11L5
ON
OFF
14567823 9101112
CONNECTEUR POUR FEU
DE CIRC. A 3 VOYANTS
MAX 100 W PAR VOYANT
SORTIE 24 Vdc
DIP-SWITCH
Elpro S20
Entrée P
Fusible
Secondaire
Transformateur
F4 = 2 A
Fusible électrovanne, beeper,
lampe clign. et led F5 = 2 A
Fusible moteur M2
F2 = 1 A
Fusible moteur M1
F1 = 1 A
SUPPORT POUR
CARTE RADIO
ENFICHABLE
Fusible
primaire
transformateur
F3 = 630 mA
20 VA - 50/60 Hz
TRANSFORMATEUR
Filtre anti-perturbation
+-
51 52 53
-
+
-
+
BEEPER
LED DE SIGNALISATION
230 V - 100 W max
COMMUN
16
17 18 51 52 53
55
56 70 71 72 51 52 53
COMMUN
M1
42
43
positif +24 Vdc
négatif 0 Vdc
11 12 14 15
41
73 74 75
F=20 A
19
20 21
COMMUN
M2
F=20 A
24 25
Electronic
circuit breaker
with capacitor
M1
40 μF
71 72
70
noir
Electronic
circuit breaker
with capacitor
M2
40 μF
74 75
73
noir
Condensateur
Moteur 1
40 μF
72
71
Condensateur
Moteur 1
40 μF
72
71
Condensateur
Moteur 2
40 μF
75
74
Condensateur
Moteur 2
40 μF
75
74
Contacteur
DESCENTE
M1
Contacteur
MONTEE
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 84 25 84 17
18
16 16
70 71
7270
Contacteur
MONTEE
M2
Contacteur
DESCENTE
M2
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 94
25
94 21 20
19
1973 75 7473
12 Vac/dc
24 Vac/dc
L3
654 3 2 1 56 55
Relais
d’Ouverture
2
Relais de
Fermeture
2
Relais
d’Ouverture
1
Relais de
Fermeture
1
L1L2
L4
L5
654 321
commun
Fc.O. 2
NF
NO
commun
Fc.F. 2
NF
NO
commun
Fc.O. 1
NF
NO
commun
Fc.F. 1
NF
NO
A2
A1
3
2
1
6
5
4
9
8
750
56
55
7
4
6
7
4
56 5515 1412 11
11 1363 55 14 1364 55
55 5 55 1 55 42 55
43
55 45 55 50 13 12 13 15
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8
+ - I1 I2 I3 I4 I5 I6 IB IC ID IE IF IG - -
55 56 63 64 1 5
40
41 44
1
2
CN1
7
8
6
5
4
3
2
1
27 55 56 23 22
22 23
26
14 15
14 15
FIN DE COURSE OUVERTURE TALOS 2
FIN DE COURSE FERMETURE TALOS 2
11 12
11 12
FIN DE COURSE OUVERTURE TALOS 1
FIN DE COURSE FERMETURE TALOS 1
910
910
Sortie 24 V - 250 mA
pour charge max:
- n° 2 paires de photocellules
- n° 1 récepteur radio
78
78
56
56
FERME
ARRET
RADIO
VOYANT 24 V - 3 W max
34
34
COMMUN
OUVRE
55 56
+-
44
451
1
PIETONS TALOS 1
PHOTOCELLULES OU
SPIRE MAGNETIQUE
42
43
40 41 44 45
ELECTROVANNE 1-3 TALOS 1
EFO
PRESSOSTAT TALOS 1
ELECTROVANNE 2 TALOS 1
42
42
ELECTROVANNE 1-3 TALOS 2
PRESSOSTAT TALOS 2
ELECTROVANNE 2 TALOS 2
24 25
ALIMENTATION
TABLEAU 400 V ± 10%
50 Hz TRIPHASEE
L1 N
84
L2
94
L3
ALIMENTATION
TABLEAU 230 V ± 10%
50 Hz MONOPHASEE
LNL L
!PONTAGE
L-L-L
58
40 58
+
-
13 16 17 18 19 20 21
FIN DE COURSE EFO CONTROLLER MOTEURS AUX
COMMANDES ET SÉCURITÉ 24 Vdc
ALIMENTATION
ACCESSOIRES
Batteries
!Eectuer les connexions électriques
sur ce bornier uniquement ALIMENTATION
27
26
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50.EFO
FR
14
Elpro S50-T2.EFO
NOTE BIEN:
- Le programmateur doit être installé dans un endroit protégé et sec.
- Appliquez un disjoncteur magnéto-thermique de haute sensibilité de 0,03 A à l’alimentation du programmateur.
- Utilisez un câble multipolaire type BUT FLEXIBLE FG 70R 12x1,5 mm², jusqu'à une distance recommandée de 20 m maximum entre
TALOS M50.EFO et ELPRO S50-T2.EFO.
- Pour des distances supérieures à 20 m, utilisez des câbles ayant une section adéquate conformément aux règles de la bonne pratique
d'installation.
- Utilisez des ls de 1 mm² pour les accessoires de commande et de sécurité.
N.B: Pour monter des accessoires supplémentaires tels que des lumières, CCTV etc. n'utilisez que des relais statiques pour éviter toute interférence
avec le microprocesseur.
EN CAS DE PANNE DE FONCTIONNEMENT DU PROGRAMMATEUR
- Assurez-vous que le programmateur électronique soit alimenté à 230 V ± 10% - 50 Hz
- Assurez-vous que le moteur électrique soit alimenté à 230 V ± 10% - 50 Hz
- Pour distances supérieures à 20 mètres, augmentez la section des ls
- Vériez l'alimentation 230 V monophasée
- Vériez les fusibles
- Vériez tous les contacts NF du programmateur
- Vériez qu'aucune chute de tension ne s'est produite entre le programmateur et le moteur électrique
Symbologie
Contact NO
Contact NF
Led allumée
Led éteinte
Voyant ou
lampe
Lampe
clignotante
Photocellules
ou spires magnetiques:
Contact pour photocellules
ou spires magnetiques
Sortie 24 Vac - 250 mA
charge max:
- n° 2 paires photocellules
- n° 1 récepteur radio
Alimentation tableau:
Accessoire Raccordements électriques Dips-switch et LED des diérentes fonctions
ALIMENTATION
TABLEAU 400 V ± 10%
50 Hz TRIPHASEE
L1 NL2 L3
ALIMENTATION
TABLEAU 230 V ± 10%
50 Hz MONOPHASEE
LNL L
!PONTAGE
L-L-L
M1 M2
Ouverture piétons:
COMMUN
CONTACT
PIETONS
ON: ferme en automatique
OFF: ne ferme pas en automatique.
Fonction semi-automatique
DIP-SWITCH N° 3 et N° 6 tous les deux sur ON:
ON: ouverture piétons moteur M1
OFF: fonctionnement standard
T2
TRIMMER
DE PAUSE
1 s - 180 s
-
+
Avec une commande piétonne, seulement la
borne escamotable reliée à M1 s’abaisse.
La fonction d'ouverture piéton n'est pas
active pendant le premier cycle de
fonctionnement qui suit une coupure de
courant.
Attention: chaque fois que l'Elpro S50-T2.EFO est remis sous tension, attendez 10 secondes pour que la logique redevienne pleinement opérationnelle.
LED DE CONTROLE
L1 = ouverture piétons, normalement éteint, s’allume avec commande ouvre piétons
L2 = photocellules ou spire, normalement allumé, s’éteint en presence d’obstacle
L3 = ouvre, normalement éteint, s’allume à l’impulsion ouvre
L4 = ferme, normalement éteint, s’allume à l’impulsion ferme
L5 = arrêt, normalement allumé, s’éteint à l’impulsion d’arrêt
L6 = radio, normalement éteint, s’allume à l’impulsion radio
L7 = normalement allumé, tension de réseau et fusibles F1, F2, F3, F4 intactes
L8 = n de course ouv. M1, normalement allumé, éteint avec borne esc. baissée
L9 = n de course ferm. M1, normalement allumé, éteint avec borne esc. levée
L10 = n de course ouv. M2, normalement allumé, éteint avec borne esc. baissée
L11 = n de course ferm. M2, normalement allumé, éteint avec borne esc. levée
DIP-SWITCH
1 = ON Photocellule ou spire arrête à l’ouv.
2 = ON Radio n’inverse pas à l’ouverture
3 = ON Ferme en automatique
4 = ON Présignalisation active
5 = ON Radio pas-pas avec arrêt intermédiaire
6 = ON Service d’une seule borne escam. piétons moteur M1
7 = ON Service homme mort
8 = Feu de circulation (voir tableau des fonctions)
9 = Feu de circulation (voir tableau des fonctions)
10 = ON Lampe de signalisation non active en pause
11 = ON Referme en pause après passage photocellules ou spire
12 = ON Temps de travail maximum 90 s. OFF = 18 s
123456789101112
ON
OFF
31910
358 3
6
1
DIP-SWITCH N° 1:
ON: Photocellule. Arrête à l’ouverture et inverse
à la fermeture avec l’enlèvement de l’obstacle
OFF: Photocellule. N’arrête pas à l’ouverture et
inverse à la fermeture avec un obstacle
11
DIP-SWITCH N° 11:
ON: Pendant la pause en automatique
(Dip-Switch 3 = ON) après le passage devant
les photocellules, ferme après 5 s
OFF: Ne ferme pas au moment du passage devant
les photocellules
L2 allumée = aucun obstacle, elle s’éteint à la
présence de l’obstacle
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50.EFO
2
DIP-SWITCH N° 2:
ON: N’inverse pas à l’ouverture
OFF: Inverse la marche à chaque impulsion
5
DIP-SWITCH N° 5:
ON: Pas-pas avec arrêt intermédiaire
OFF: Fonctionnement normal
L7 éteinte = aucun contact RADIO, elle s’allume
à chaque impulsion du contact radio
4
DIP-SWITCH N° 4:
ON: Pré-clignotement avec beeper
OFF: Sans pré-clignotement avec beeper
10
DIP-SWITCH N° 10:
ON: Clignotement et/ou beeper desactivé
pendant la pause en automatique
OFF: Clignotement et/ou beeper activé
pendant la pause en automatique
FR
15
Elpro S50-T2.EFO
On peut raccorder aussi, en plus des leds
intégrées dans la borne escamotable, une
lampe clignotante externe.
Cela fonctionnera pendant la montée et la
descente et pendant la pause (si elle est
dénie).
230 V - 100 W max
Sélecteur à clé:
12
DIP-SWITCH N° 12:
ON: Temps de travail max 90 s
OFF: Temps de travail max 18 s
Contacts NO et NF à brancher sur les bornes
correspondantes des sélecteurs ou des boîtes
boutons poussoirs. Toutes les possibles
congurations sont jointes aux accessoires
de commande réspectifs.
Voyant allumé = colonne baissée, passage libre
Voyant éteint = colonne levée, passage fermé
Clignotement à 0,5 s (rapide) =
mouvement de montée
Clignotement à 1 s (normal) =
mouvement de descente
Avec horloge externe: 2 brefs clignotements
suivis par une pause plus longue
Voyant 24 V - 3 W max
pour la signalisation
du mouvement:
Moteurs:
Fin de course:
T2
TEMPS DE PAUSE
1 s - 180 s
T1
TEMPS DE TRAVAIL
1 s - 22 s
-
+
-
+
Led de signalisation:
Sortie pour leds à lumière intermittente
toujours fonctionnantes pendant le
mouvement de montée et de descente et
en arrêt avec la borne en position levée.
Elles s’éteintent avec la colonne baissée.
Le beeper est dans la borne escamotable et il
est actif seulement pendant le mouvement de
montée et de descente.
Beeper de mouvement
et/ou lampe
clignotante:
L3 éteinte = aucun contact ouvre, elle s’allume à
chaque impulsion d’ouverture
L4 éteinte = aucun contact ferme, elle s’allume à
chaque impulsion de fermeture
L5 allumée = contact d’arrêt fermé, elle s’éteint à
chaque impulsion d’ârret
L8 allumée = s’éteint avec la colonne 1 baissée
L9 allumée = s’éteint avec la colonne 1 levée
MOTEUR 1
Borne escamotable 1
16 17 18
M1
COMMUN
COMMUN LED
ET/OU BEEPER
LED
MOTEUR 2
Borne escamotable 2
19 20 21
COMMUN
M2
L10 allumée = s’éteint avec la colonne 2 baissée
L11 allumée = s’éteint avec la colonne 2 levée
COMMUN LED
ET/OU BEEPER
BEEPER ET/OU
LAMPE CLIGNOTANTE
Accessoire Raccordements électriques Dips-switch et LED des diérentes fonctions
Contact radio: En raccordant un n’importe quel contact NO entre
les deux bornes on peut avoir à chaque impulsion:
- Seulement ouverture:
Dip 2 = ON et Dip 5 = OFF
- Inversion de marche à chaque impulsion
Dip 2 = OFF et Dip 5 = OFF
- Pas-pas: ouvre - arrêt- ferme - arrêt
Dip 2 = OFF et Dip 5 = ON
- En phase d’ouverture il n’accepte aucune
commande. En pause et en fermeture à chaque
commande il fait l’arrêt avec l’inversion de
marche: Dip 2 = ON et Dip 5 = ON
F=20A
F=20A
FERME
ARRET
COMMUN
OUVRE
NF
5634
CONTACT RADIO
RADIO
COMMUNCOMMUN
73
83
n de course fermet.
TALOS 1
n de course ouvert.
TALOS 1
n de course ouvert.
TALOS 2
n de course fermet.
TALOS 2
12
14
15
11
positif +24 Vdc
négatif 0 Vdc
55 56
+-
51 52 53
51 52 53
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50.EFO
DIP-SWITCH N° 8 et N° 9:
Carte feu de circulation enchable
(en option):
L’alimentation de la carte est indépendante de cela de la
carte du programmateur:
- 230 V - 50 Hz avec sortie de 100 W à 230 V par voyant.
- 24 V avec sortie de 25 W par voyant.
- 12 V avec sortie de 22 W par voyant.
Fonctionnement aussi pour feu de circulation à 2
voyants rouge et vert (Dip-Switch 8 = OFF et 9 = OFF).
Logique de Fonctionnement:
- Lumière VERTE = colonne baissée, passage OUVERT
- Lumière ROUGE = colonne en mouvement ou levée,
passage FERME
- Lumière JAUNE = elle s’allume avant le passage de la
lumière verte à la lumière rouge.
Note: avec le fonctionnement piéton le feu de
circulation est toujours ROUGE.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF et 9 = OFF
S’allume le jaune pour 0 s
et après 0 s s’allume le rouge et la
colonne se lève immédiatement.
Dip-Switch 8 = ON et 9 = OFF
S’allume le jaune pour 2 s, ensuite
s’allume le rouge et après 2 s, se
lève la colonne.
Dip-Switch 8 = OFF et 9 = ON
S’allume le jaune pour 6 s, ensuite
s’allume le rouge et après 5 s se
lève la colonne.
Dip-Switch 8 = ON et 9 = ON
S’allume le jaune pour 10 s, ensuite
s’allume le rouge et après 7 s se
lève la colonne.
ROUGE
JAUNE
VERT
Rouge
Jaune
Vert
Fusible 1 A
(Option: carte feu de circulation
enchable pour voyants à 230 V,
24 V ou 12 V).
Code 7282L
Rouge
Jaune
Vert
Alimentation
230 V - 50 Hz,
24 V ou 12 V
Commun
63 64 65 66 60 61
FR
16
Elpro S50-T2.EFO
Description Dips-switch et LED des diérentes fonctions
3
DIP-SWITCH N° 3:
ON: Ferme en automatique
OFF: Ne ferme pas en automatique.
Fonction semi-automatique
T2
TEMPS DE PAUSE
1 s - 180 s
-
+
FONCTIONS
7
DIP-SWITCH N° 7:
ON: Fonctionnement à homme mort
OFF: Functionnement normal
Homme mort:
Les opérations d’ouverture et de fermeture sont réalisées “en appuyant
un bouton” (sans auto-maintien des relais). Par conséquent, il est
demandée la présence active de l’opérateur pendant tout le mouvement
de l’automation jusqu’à la relâche du bouton ou de la clé du sélecteur.
Automatique / semi-automatique:
Cycle automatique: à une impulsion de commande ouvre, la colonne s’abaisse et elle arrête en pause
pour le temps reglé sur le trimmer T2. Expiré ce temps, elle se lève automatiquement.
Cycle semi-automatique: à une impulsion de commande ouvre, la colonne s’abaisse. Pour fermer le
passage, il faut donner une impulsion de fermeture.
3
DIP-SWITCH N° 3:
ON: Ferme en automatique
OFF: Ne ferme pas en
automatique.
Fonction semi-automatique
T2
TEMPS DE PAUSE
1 s - 180 s
-
+
Horloge externe (en option):
HORLOGE: le programmateur Elpro S50-T2.EFO permet le branchement d’un horloge normal pour la
montée et la descente de la borne escamotable.
Raccordement: raccordez en parallèle le contact NO de l’horloge avec la borne n° 4 ouvre et n° 3 commun,
en activant la refermeture automatique avec le Dip-Switch n° 3 = ON.
Fonctionnement: réglez l’horloge sur le temps d’ouverture demandé, à l’heure établie la borne
escamotable s’abaisse (le voyant signale 2 brefs clignotements suivis par une pause plus longue).
Il n’acceptera plus aucune commande (même radio) jusqu’à l’éxpiration du temps établi sur l’horloge.
A l’éxpiration de ce temps, après le temps de pause, il y aura la montée automatique.
EFO: Emergency Fast Operation
Le dispositif d'urgence EFO permet de soulever rapidement la borne dans environ 1,5 seconde, garantissant une protection maximale dans les situations d'extrême
nécessité et de danger. Étant un dispositif d'urgence, il doit être utilisé seulement en cas de besoin réel; en fait, son activation désactive tous les dispositifs de sécurité
présents et installés, causant des potentielles dommages aux personnes et aux choses à proximité immédiate de la borne escamotable.
Meccanica Fadini décline toute responsabilité en cas d'utilisation inappropriée de ce dispositif et des éventuels dommages causés aux personnes et aux biens lors de
son utilisation. L'activation du EFO se fait au moyen d'un bouton d'urgence (non fourni) et en cas de coupure de courant son fonctionnement, vitesse de remontée
supérieure à celle standard, est garanti pendant une courte période (environ une heure). Une fois activé, le dispositif EFO est capable de se réinitialiser pour une
éventuelle prochaine activation (aucune action externe d'un opérateur physique n'est requise). Il est à noter que, lorsque la borne escamotable est en position de
dissuasion (cylindre complètement levé), le groupe hydraulique continue à fonctionner pendant quelques secondes: il s'agit d'une opération correcte car, dans ce cas,
le dispositif se réinitialise.
CONTACT
D'URGENCE
EFO
COMMUN
EFO
340
ELECTROVANNE 1-3
TALOS 1
PRESSOSTAT
TALOS 1
ELECTROVANNE 2
TALOS 1
ELECTROVANNE 1-3
TALOS 2
PRESSOSTAT
TALOS 2
ELECTROVANNE 2
TALOS 2
42
43
44
4542
41
positif +24 Vdc
négatif 0 Vdc
55 56
+-
Raccordements électriques EFO
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50.EFO
DANKE
Danken, dass Sie sich für ein Fadini Produkt entschieden haben.
Bitte lesen Sie diese Gebrauchsanleitung sehr sorgfältig bevor Sie das
Gerät in Betrieb nehmen. Sie enthält wichtige Informationen, damit
Sie viel Freude an Ihrem Gerät haben und ein sicherer und sauberer
Betrieb gewährleistet ist.
Bewahren Sie dieses Handbuch gut auf, damit Sie bei Bedarf immer
wieder darauf zurückgreifen können.
EINFÜHRUNG
Diese Automation ist ausschließlich für den in dieser
Betriebsanleitung angegebenen Verwendendungszweck entwickelt
worden, mit den mindesten erforderlichen Sicherhetszubehörteilen,
dem Bedien- und Signalisierungszubehör und Fadini Vorrichtungen.
Jede beliebige andere Anwendung, die nicht extra in diesem
Handbuch angegeben worden ist, könnte zu Funktionsstörungen und
Schäden an Dingen und Personen führen Meccanica Fadini S.r.l. ist
nicht für eventuelle Schäden verantwortlich, die durch nicht gerechte
und nicht spezisch in diesem Handbuch angegebe Verwendung
verursacht werden und haftet außerdem nicht für Betriebsstörungen,
die durch die Verwendung von Materialien oder Zubehörteilen, die
nicht von der Firma selbst angegeben worden sind, entstanden sind.
Die Herstellerrma behält sich Änderungen an eigenen Produkten
ohne Vorankündigung vor Alles, was nicht ausdrücklich in dieser
Anleitung angegeben ist, ist nicht erlaubt.
VOR DER INSTALLATION
Vor jedem Eingri ist die Eignung des zu automatisierenden Eingangs
zu beurteilen, sowie dessen Zustand und Struktur. Stellen Sie sicher,
dass es keine Situationen zum Aufprall, Zerkleinern, Scheren,
Schleppen, Schneiden, Einhaken und Heben entstehen, die die
Sicherheit von Personen gefährden können. Dieses Produkt nicht in
der Nähe von Wärmequellen installieren und der Kontakt mit
brennbaren Stoen vermeiden. Alle Geräte (Sender, Proximity-Leser,
Schalter, etc.) dürfen nicht in die Hände von Kindern gelassen werden.
Übergang ist nur bei der gestoppten Automation erlaubt Lassen
Sie nicht Kinder und / oder Erwachsene, um in der Nähe der Anlage
mit der Automatisierung in Bewegung stehen. Um ein
angemessenes Sicherheitsniveau der Anlage zu gewährleisten ist
notwendig, um die Art der Installationbedienung zu identizieren und
dann im Zusammenhang mit dem Endkunden zu setzen; dann
Lichtschranken, Kontaktleisten, Magnetspulen und Präsenzsensoren
verwenden, um das gesamte betroene Gebiet, um die Bewegung
des Tors (besonders die Ränder der Flügel in Bewegung) gefahrlos zu
machen. Verwenden Sie gelb-schwarze Streifen oder entsprechende
Signale, um die Gefahrenstellen der Installation zu identizieren. Die
Spannung an das System abschalten, wenn Wartung und / oder
Reinigung durchzuführen sind. Wird der Antrieb entfernt, die Drähte
nicht schneiden, aber entfernen Sie sie aus dem Klemmenblock durch
Lösen der Schrauben im Anschlusskasten.
INSTALLATION
Die gesamte Installation muss von qualiziertem technischen
Personal unter Einhaltung der Maschinenrichtlinie 2006/42/CE und
besonders der Normen EN 12445 und EN 12453 durchgeführt werden.
Überprüfen Sie die Anwesenheit aufwärts der Anlage, eines
Magnetothermischen Dierentialhauptschalter 230 V - 50 Hz 0,03 A
Verwenden Sie Testkörper für die Funktionsprüfung in der Erfassung
der Gegenwart, in der Nähe von Sicherheitseinrichtungen wie
Lichtschranken, Sicherheitsleisten, etc.. Führen Sie eine sorgfältige
Risikoanalyse unter Verwendung geeigneter Instrumenten zur
Erkennung von Schlag-und Druck der Vorderkante des Önen und
Schließen, wie in EN 12445 festgelegt. Identizieren Sie die beste
Lösung zur Beseitigung oder Verringerung dieser Risiken. In dem
Fall, wo das Tor zu automatisieren wurde mit einem Fußgänger-
Eingang ausgestattet, ist es zweckmäßig, das System in einer Weise
herzustellen, um den Betrieb des Motors zu verhindern, wenn der
Fußgänger-Eingang verwendet wird. Die Anwesenheit der
Automation mit der Anwendung am Tor eines Warnschilds mit
CE-Kennzeichnung ist zu signalisieren.
Das Installateur wird benötigt, um über die richtige Nutzung des
Systems Information und Aufklärung dem Endkunden zu geben;
Layout und Komponenten des Systems, Risikoanalyse, Überprüfung
der Sicherheitsausrüstung, Überprüfung der Aufprallkräfte und
Berichterstattung von Restrisiken: dies wird durch die Gewährung
von ihm einer signierten Dokumentation denierten technischen
Dossiers getan.
HINWEISE FÜR ENDBENUTZER
Der Endbenutzer ist verpichtet, Informationen nur über den Betrieb
des Systems zu empfangen und zu lesen und wird sich für die korrekte
Verwendung verantwortlich. Er muss einen Vertrag für ordentliche
und außerordentliche Wartung (auf Abruf) mit dem Installateur /
Betreuer schließen. Eine Reparatur darf nur von qualiziertem
Fachpersonal durchgeführt werden. Halten Sie diese
Bedienungsanleitung.
HINWEISE UM DEN EINWANDFREIEN BETRIEB DES SYSTEMS
Für eine langfristig optimale Leistung der Anlage entsprechend den
Sicherheitsnormen ist es notwendig die gesamte Anlage durch
qualiziertes Personal korrekt zu warten und zu kontrollieren, sowohl
was die Automation als auch die installierten elektronischen Geräte
und deren Verkabelungen betrit. Die gesamte Anlage muss von
qualizierten Technikern durchgeführt werden, wobei das
Dokuments zur Überprüfung und zum Test und das im Handbuch
Sicherheitsbestimmungen gezeigt Wartungsprotokoll auszufüllen
sind (auf Anfrage oder von der Website www.fadini.net/support/
downloads heruntergeladen). Für die Automatisierung wird
empfohlen, eine Wartungsprüfung mindestens alle 6 Monate,
während für elektronische Geräte und Sicherheitssysteme eine
monatliche Wartung. Meccanica Fadini S.r.l. haftet nicht für die
Nichteinhaltung der regelgerechten Installationstechnik und/oder
unsachgemäße Wartung des Systems.
ENTSORGUNG VON MATERIALIEN
Verpackungsmaterial wie Pappe, Kunststo, Polystyrol, etc.. kann
durch die getrennte Sammlung entsorgt werden (nach Prüfung der
geltenden Bestimmungen am Ort der Installation im Bereich der
Abfallbeseitigung). Elektrischen, elektronischen Elements und
Batterien können Schadstoe enthalten: Entfernen und anvertrauen
diese Komponenten an Unternehmen, die bei der Verwertung von
Abfällen spezialisiert sind, wie in der Richtlinie 2012/19/UE festgelegt.
Es ist verboten, umweltschädliche Materialien in den Hausmüll zu
werfen.
ALLGEMEINE HINWEISE FÜR DIE SICHERHEIT VON PERSONEN
Meccanica Fadini S.r.l.
Betriebsleiter
EU-KONFORMITÄTSERKLÄRUNG
Hersteller: Meccanica Fadini S.r.l.
Adresse: Via Mantova, 177/A - 37053 Cerea - VR - Italy
erklärt auf eigene Verantwortung, dass das Produkt:
Steuerzentrale Modell ELPRO S50-T2.EFO
es erfüllt die einschlägigen Harmonisierungsrechtsvorschriften der
Union:
- Richtlinie über Elektromagnetische Verträglichkeit 2014/30/UE
- Niederspannungsrichtlinie 2014/35/UE
Cerea, 13/10/2017
E-STEUERUNG FÜR TALOS M50.EFO
ANTI-TERROR VERSENKBARE POLLER
DE
17
Elpro S50-T2.EFO
E-STEUERUNG FÜR TALOS M50.EFO
ANTI-TERROR VERSENKBARE POLLER
DE
18
Elpro S50-T2.EFO
58
56
1 4 5 678910
ELPRO S20
T2
PAUSEZEIT
1 s - 180 s
T1
BETRIEBSZEIT
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9 L10 L11L5
ON
OFF
14567823 9101112
STECKPLATZ FÜR AMPEL
MIT 3 LICHTERN,
MAX 100 W PRO LICHT
24 Vdc
AUSGANG
DIP-SWITCH
Elpro S20
Input P
Sekundär-
sicherung
Transformator
F4 = 2 A
Sicherung für Elektroventil, Piepser,
Blinkleuchte und LEDs F5 = 2 A
M2 Motor Sicherung
F2 = 1 A
M1 Motor Sicherung
F1 = 1 A
STECKSOCKEL FÜR
EINSTECKEMPFÄNGER
Primär-
sicherung
Transformator
F3 = 630 mA
20 VA - 50/60 Hz
TRAFO
Störungsschutzlter
+-
51 52 53
-
+
-
+
PIEPSER
SIGNAL-LEDs
230 V - 100 W max
COMMON
16
17 18 51 52 53
55
56 70 71 72 51 52 53
COMMON
M1
42
43
Positiv +24 Vdc
Negativ 0 Vdc
11 12 14 15
41
73 74 75
F=20 A
19
20 21
COMMON
M2
F=20 A
24 25
Electronic
circuit breaker
with capacitor
M1
40 μF
71 72
70
schwarz
Electronic
circuit breaker
with capacitor
M2
40 μF
74 75
73
schwarz
Motor 1
Kondensator
40 μF
72
71
Motor 1
Kondensator
40 μF
72
71
Motor 2
Kondensator
40 μF
75
74
Motor 2
Kondensator
40 μF
75
74
Schaltschütz
EINFAHREN
M1
Schaltschütz
AUSFAHREN
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 84 25 84 17
18
16 16
70 71
7270
Schaltschütz
AUSFAHREN
M2
Schaltschütz
EINFAHREN
M2
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
25 94
25
94 21 20
19
1973 75 7473
12 Vac/dc
24 Vac/dc
L3
654 3 2 1 56 55
Önun
Relais 2
Schließung
Relais 2
Önun
Relais 1
Schließung
Relais 1
L1L2
L4
L5
654 321
Common
Fc.A. 2
NC
NO
Common
Fc.C. 2
NC
NO
Common
Fc.A. 1
NC
NO
Common
Fc.C. 1
NC
NO
A2
A1
3
2
1
6
5
4
9
8
750
56
55
7
4
6
7
4
56 5515 1412 11
11 1363 55 14 1364 55
55 5 55 1 55 42 55
43
55 45 55 50 13 12 13 15
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8
+ - I1 I2 I3 I4 I5 I6 IB IC ID IE IF IG - -
55 56 63 64 1 5
40
41 44
1
2
CN1
7
8
6
5
4
3
2
1
27 55 56 23 22
22 23
26
14 15
14 15
Önung Endschalter TALOS 2
Schließung Endschalter TALOS 2
11 12
11 12
Önung Endschalter TALOS 1
Schließung Endschalter TALOS 1
910
910
24 V - 250 mA AUSGANG
für max Belastung:
- n° 2 Lichtschranken
- n° 1 Funkempfänger
78
78
56
56
ZU
STOP
FUNK
Licht 24 V - 3 W max
34
34
COMMON
AUF
55 56
+-
44
451
1
FUSSGÄNGER TALOS 1
LICHTSCHRANKE ODER
INDUKTIONSSCHLEIFE
42
43
40 41 44 45
ELEKTROVENTIL 1-3 TALOS 1
EFO
DRUCKWÄCHTER TALOS 1
ELEKTROVENTIL 2 TALOS 1
42
42
ELEKTROVENTIL 1-3 TALOS 2
DRUCKWÄCHTER TALOS 2
ELEKTROVENTIL 2 TALOS 2
24 25
KARTE
STROMVERSORGUNG
400 V ± 10% 50 Hz
DREIPHASIG
L1 N
84
L2
94
L3
KARTE
STROMVERSORGUNG
230 V ± 10% 50 Hz
EINPHASIG
LNL L
!JUMPER
L-L-L
58
40 58
+
-
13 16 17 18 19 20 21
ENDSCHALTER EFO CONTROLLER MOTOREN AUX
KONTROLLEN UND SICHERHEIT 24 Vdc
ZUBEHÖR STROM-
VERSORGUNG
Batterien
!
Stellen Sie die elektrischen
Verbindungen nur an diesem
Klemmenblock her STROMVERSORGUNG
27
26
E-STEUERUNG FÜR TALOS M50.EFO
ANTI-TERROR VERSENKBARE POLLER
DE
19
Elpro S50-T2.EFO
WICHTIG:
- Der Steuerung muss an einem trockenen und geschützten Ort installiert werden.
- An der Stromversorgung der Steuerung einen hochsensiblen magneto-thermischen 0,03 A Dierential-Schalter anbringen.
- Verwenden Sie einen Multipol-Kabeltyp BUT FLESSIBILE FG 70R 12x1,5 mm², bis zu einer empfohlenen Entfernung von 20 m maximum
zwischen TALOS M50.EFO und ELPRO S50-T2.EFO.
- Für Enternungen von über 20 m verwenden Sie Kabel mit einer Adernqueschnitt, die den Regeln einer guten Installationpraxis entsprechen.
- Verwenden Sie Kabel mit 1 mm² Adernquerschnitt für Bedienungs-und Sicheheitszubehör.
NB: Für Spezialanwendungen wie z.B. Lichter, Überwachungskameras, usw. muß man statische Relais verwenden, damit es nicht zu
Steuerungen am Mikroprozessor kommt.
BEI FUNKTIONSSTÖRUNGEN:
- Kontrollieren Sie, daß die Stromversorgung der Steuerung 230 V ±10% - 50 Hz ist
- Kontrollieren Sie, daß die Stromversorgung des E-Motors 230 V ±10% - 50 Hz ist
- Bei Entfernungen über 20 Meter den Adernquesrschnitt der Kabel vergrößern
- Die Versorgungsspannung (230 V einphasig) kontrollieren
- Die Sicherungen kontrollieren
- Alle NC Kontakte der Steuerung kontrollieren
- Kontrollieren, daß kein Spannungsabfall zwischen der Steuerung und dem E-Motor vorliegt
Symbole
NO Kontakt
NC Kontakt
LED ON
LED OFF
Anzeigelicht
oder Leuchte
Blinkleuchte
Lichtschranken oder
Induktionsschleife:
KONTAKT FÜR
LICHTSCHRANKEN
ODER
INDUKTIONSSCHLEIFE
Ausgang 24 Vac - 250 mA
MAXIMALE BELASTUNG:
- NR. 2 LICHTSCHRANKENPAARE
- NR. 1 FUNKEMPFÄNGER
Karte Stromversorgung:
Zubehör Elektrische Anschlüsse Dip-Schalter u. LED Status der verschiedenen Funktionen
STROMVERSORGUNG
KARTE 400 V ± 10%
50 Hz DREIPHASIG
L1 NL2 L3
STROMVERSORGUNG
KARTE 230 V ± 10%
50 Hz EINPHASIG
LNL L
!JUMPER
L-L-L
Gehtürfunktion:
COMMON
GEHTÜR-
KONTAKT
ON: automatisches Schließen
OFF: kein automatisches Schließen
Halbautomatik-Funktion
DIP-SCHALTER Nr. 3 u. Nr. 6 beide auf ON:
ON: Gehtürfunktion Motor M1
OFF: normalbetrieb
T2
TRIMMER
PAUSE
1 s - 180 s
-
+
Durch einen Fußgängerbefehl wird nur der
mit M1 verbundene Poller abgesenkt.
Die Fußgängerönungsfunktion kann
während des ersten Betriebszyklus nach
einem Stromausfall nicht aktiviert werden.
Achtung: Jedes mal dass Elpro S50-T2.EFO mit Strom wieder versorgt wird, warten Sie 10 Sekunden, damit die Steuerlogik regelmäßig wieder funktioniert.
DIAGNOSE-LEDS
L1 = Fußgängerönung, normalerweise AUS, leuchtet bei Betätigung der
Fußgängerfunktion
L2 = Lichtschranke oder Induktionsschleife, normalerweise AN, geht bei vorhandenem
Hindernis aus
L3 = Önen, normalerweise AUS, leuchtet bei Betätigung des Impulses Önen auf
L4 = Schließen, normalerweise AUS, leuchtet bei Betätigung des Impulses Schließen auf
L5 = Blockierung, normalerweise AN, geht bei Betätigung des Impulses Blockieren aus
L6 = Funkfernsteuerung, normalerweise AUS, leuchtet bei Impuls des Funkhandsenders auf
L7 = Normalerweise AN, Netzspannung und Integrität der Sicherungen F1, F2, F3, F4
L8 = Endschalter Önen M1, normalerweise AN, bei eingefahrenem Poller aus
L9 = Endschalter Schließen M1, normalerweise AN, bei ausgefahrenem Poller aus
L10 = Endschalter Önen M2, normalerweise AN, bei eingefahrenem Poller aus
L11 = Endschalter Schließen M2, normalerweise AN, bei ausgefahrenem Poller aus
DIP-SWITCH
1 = ON Lichtschranke oder Induktionsschleife
hält beim Önen an
2 = ON Funksteuerung reversiert beim Önen nicht
3 = ON Autozulauf
4 = ON Vorblinken aktiviert
5 = ON Funksteuerung Impulsbetrieb mit Zwischenstop
6 = ON Betrieb nur eines Fußgängerabsperrpollers Motor M1
7 = ON Totmann-Betrieb
8 = Steuerung Ampel (siehe Seite der Funktionen)
9 = Steuerung Ampel (siehe Seite der Funktionen)
10 = ON Blinkleuchte ausgeschaltet in Pause
11 = ON Schließt wieder in Pause nach Durchgang durch Lichtschranke
oder Induktionsschleife
12 = ON Maximale Betriebszeit 90 s. OFF = 18 s
123456789101112
ON
OFF
31910
358 3
6
M1 M2
1
DIP-SCHALTER Nr. 1:
ON: Lichtschranke. Hält beim Önen an, kehrt beim
Schließen nach Entfernung des Hindernisses um
OFF: Lichtschranke. Hält beim Önen nicht an, kehrt
beim Schließen bei vorhandenem Hindernis um
11
DIP-SCHALTER Nr. 11:
ON: Während der Pause, in Automatik,
(Dip-Schalter 3 = ON) schließt beim Durchgang
durch die Lichtschranke nach 5 s
OFF: Es schließt beim Durchgang durch die
Lichtschranke nicht
L2 ON = Kein Hindernis. Es schaltet bei einem
Hindernis aus
E-STEUERUNG FÜR TALOS M50.EFO
ANTI-TERROR VERSENKBARE POLLER
DE
20
Elpro S50-T2.EFO
Zusätzlich zu den eingebauten LED-
Leuchten können Sie eine externe
Blinkleuchte an den Poller anschliessen. Die
Blinkleuchte wird während der Auf- und
Abbewegungen und während der Pausezeit
eingeschaltet (falls vorausgewählt).
230 V - 100 W max
Schlüsselschalter: NO und NC Kontakte, die an den
jeweilige Klemmen der Schlüsselschalter oder
Drückknöpfe anzuschliessen sind.
Alle möglichen Kongurationen sind in
der Anweisungen der jeweiligen
Steuerzubehör beschrieben
Licht ON = Poller eingefahren, Durchfahrt freigeben
Licht OFF = Poller ausgefahren, Durchfahrt gesperrt
Blinken 0,5 s (schnell) = Phase des Hebens
Blinken 1 s (normal) = Phase des Senkens
Mit externer Uhr: 2 kurzes Blinken,
gefolgt von einer längerer Pause
24 V - 3 W max.
Anzeigelampe
zur Signalisierung
der Bewegung:
Motoren:
Endschalter:
Signal-LEDs:
Ausgang für LED-Lichter, intermittierend,
die während der Bewegung des Aus- und
Einfahrens und bei ausgefahrenem Poller
ständig funktionieren.
Sie schalten bei eingefahrenem Poller aus.
Die akustische Vorrichtung bendet sich
innerhalb des Pollers und ist nur während der
Auf- und Absenkbewegungen des Pollers
eingeschaltet.
Piepser, bei Bewegung
und/oder Blinkleuchte:
L8 ON = es schaltet bei eingefahrenem Poller 1 aus
L9 ON = es schaltet bei ausgefahrenem Poller 1 aus
Poller 1
MOTOR 1
16 17 18
M1
COMMON
LED COMMON
und/oder PIEPSER
LED
Poller 2
MOTOR 2
19 20 21
COMMON
M2
L10 ON = es schaltet bei eingefahrenem Poller 2 aus
L11 ON = es schaltet bei ausgefahrenem Poller 2 aus
LED COMMON
und/oder PIEPSER
PIEPSER und/oder
BLINKLEUCHTE
Zubehör Elektrische Anschlüsse Dip-Schalter u. LED Status der verschiedenen Funktionen
Funkkontakt: Bei jedem NO Anschluss an diese beide Klemmen,
wird es bei jedem Impuls wie folgt ausgeführt:
- Nur Önung: Dip 2 = ON und Dip 5 = OFF
- Laufumkehr bei jeder Impulsgabe
Dip 2 = OFF und Dip 5 = OFF
- Schritt-für-Schritt: Auf - Stop - Zu - Stop
Dip 2 = OFF und Dip 5 = ON
- Beim Önen wird kein weiterer Befehl akzeptiert.
Stop und Umkehr bei Pausezeit und Schließen
wenn ein Impuls gegeben wird:
Dip 2 = ON und Dip 5 = ON
F=20A
F=20A
ZU
STOP
COMMON
AUF
NC
5634
FUNKKONTAKT
FUNK
COMMONCOMMON
73
83
Schließung
Endschalter TALOS 1
Önung
Endschalter TALOS 1
Önung
Endschalter TALOS 2
Schließung
Endschalter TALOS 2
12
14
15
11
Positiv +24 Vdc
Negativ 0 Vdc
55 56
+-
51 52 53
51 52 53
L3 OFF = Kein AUF Kontakt, es schaltet an,
wann ein Impuls zum Önen gegeben
wird
L4 OFF = Kein ZU Kontakt, es schaltet an,
wann ein Impuls zum Schließen
gegeben wird
L5 ON = Stop-Kontakt geschlossen, es schlatet aus
wann ein Stop-Impuls gegeben wird
2
DIP-SCHALTER Nr. 2:
ON: Keine Umkehrung beim Önen
OFF: Kehrt die Laufrichtung bei jedem Impuls um
5
DIP-SCHALTER Nr. 5:
ON: Impulsbetrieb mit Zwischenstopp
OFF: Normalbetrieb
L7 OFF = Kein FUNK KontaKt, es schaltet bei
jeder Funk-Impulsgabe an
12
DIP-SCHALTER Nr. 12:
ON: Max. Betriebszeit 90 s
OFF: Max. Betriebszeit 18 s
T2
PAUSEZEIT
1 s - 180 s
T1
MOTOR BETRIEBSZEIT
1 s - 22 s
-
+
-
+
4
DIP-SCHALTER Nr. 4:
ON: Vorblinken mit Piepser
OFF: Kein Vorblinken mit Piepser
10
DIP-SCHALTER Nr. 10:
ON: Blinkleuchte und/oder Piepser nicht aktiviert
während der Pause in Automatik
OFF: Blinkleuchte und/oder Piepser während
der Pause in Automatik
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Fadini elpro-s50-T2.EFO Instructions Manual

Taper
Instructions Manual

dans d''autres langues