42995-01 05/08/2006 © 2006 Hunter Fan Company
Replacement Filter Information
Model
30750
Pre-Filter
30901
41782-01.pmd 6/7/05, 2:33 PM1
42995-01 2
Table of Contents
Safety Instructions ..................................................................................................3
Introduction ............................................................................................................3
Description of Air Filtration System
How the Air Purifier Works............................................................................4
Air Purifier Components ................................................................................4
Display and Control Keys ..............................................................................5
Operation
Initial Operation .............................................................................................6
Filter Life Counters ........................................................................................8
Locking/Unlocking the Keypad ..................................................................... 8
Resetting the Air Purifier ............................................................................... 9
Using the Ionizer ............................................................................................ 9
Controlling the Backlight ...............................................................................9
Air Purifier Maintenance
Cleaning Your Air Purifier............................................................................ 10
Changing the Pre-Filter ................................................................................10
Cleaning the Filter ........................................................................................11
Obtaining Replacement Filters.....................................................................13
Troubleshooting
Problem and Solutions .................................................................................14
Technical Support .........................................................................................14
Warranty Information .........................................................................................15
41782-01.pmd 6/7/05, 2:33 PM2
3 42995-01
SAFETY INSTRUCTIONS
IMPORTANT!
READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER.
1. This air purifier is designed for use on a flat level floor and may not work properly on
an uneven floor. ALWAYS place the air purifier on a firm level floor. ALWAYS place
the air purifier at least six (6) inches away from walls and heat sources such as stoves,
radiators, or heaters.
2. Place the air purifier in an area that is out of the reach of children.
3. Before using the air purifier, extend the cord and inspect for any signs of damage. DO NOT
use the product if the cord has been damaged.
4. This product has a polarized plug (one blade is wider than the other) as a safety feature.
This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the
outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician. DO
NOT attempt to defeat or override this safety feature.
5. ALWAYS UNPLUG the air purifier while it is being cleaned.
6. DO NOT move or tilt the air purifier while it is in operation. Turn off and unplug before
moving.
7. DO NOT immerse the air purifier in water at any time because permanent damage will
occur. To properly clean your air purifier, follow the instructions in the Maintenance section
of this manual (pg. 10).
READ AND SAVE ALL INSTRUCTIONS.
Introduction
Thank you for purchasing the PermaLife
Air Purifier from Hunter Fan Company. You have
purchased our latest development in portable air purification which has been designed to im-
prove the quality of the air that you breathe. The following innovative features are included in
your Hunter Air Purifier.
High Particulate Efficiency: The cleanable filter will remove 99.5% of 0.5 micron particles
from the air that passes through the filter.
Odor Removal: The activated carbon pre-filter helps remove odors such as cooking, smoke,
and pet smells from the air. It also traps lint, hair, and other large particles to help extend the
life and performance of the cleanable filter.
Ionizer: The ionizer improves the quality of air in the room by releasing negative ions into
the air that attract positively charged dust, smoke, and pollen particles.
Quiet: The air purifier has been designed to operate quietly and efficiently. You can choose
among three speeds to best meet your needs at different times.
•Filter Counters: Filter maintenance is critical to the performance of the air purifier. To help
you determine when to change or clean the pre-filter and cleanable filter, the unit has built in
life counters that keep track of the life remaining of each filter.
NiteGlo™ Light: Your air purifier display has a backlight that is continuously lit as long as
there is power to the unit. You can choose to turn the backlight off or on.
41782-01.pmd 6/7/05, 2:33 PM3
42995-01 4
Description of Air Filtration System
Air Purifier Components
Fig. 1 - Illustration of the Air Filtration System
Fig. 2 - Air Purifier Components
CLEANABLE
FILTER
PRE-FILTER
FRONT
GRILL
BASE
Dust & Irritants
Pollen & Allergens Odors Bacteria Pet Hair & Dander
Carbon
Pre-filter
PermaLife™
Cleanable
Filtration System
99.5% – .5 Microns
Ionizer
How the PermaLife
Air Purifier System Works
As the air is pulled into the purifier, the activated carbon pre-filter absorbs odors and catches
large particles. Then, the air travels through the PermaLife™ Cleanable Filtration System
where the smaller particles are collected. Then, the ionizer releases negative ions into the air
that attract positively charged dust, smoke, and pollen particles. Finally, the clean purified
air is released back into the room.
41782-01.pmd 6/7/05, 2:33 PM4
5 42995-01
Description of Air Filtration System
Display and Control Keys
The display and control keys allow for easy operation of the air purifier.
UP/DOWN KEYS: Adjusts the blower speed and turns the unit on and off.
PRE-FILTER RESET: Resets the Carbon Pre-Filter Life Counter.
FILTER RESET: Resets the Cleanable Filter Life Counter.
IONIZER KEY: Turns the ionizer on and off.
Fig. 3 - Air Purifier Control Area and Alpha-numeric Display
CLEANABLE
FILTER LIFE
COUNTER
KEYPAD
LOCKED
INDICATOR
BLOWER
SPEED
PRE-FILTER
LIFE COUNTER
ANIMATED
BLOWER
IONIZER
INDICATOR
UP/DOWN
KEYS
PRE-FILTER
RESET KEY
FILTER
RESET KEY
IONIZER
KEY
CLEANABLE
FILTER
INDICATOR
CARBON
PRE-FILTER
INDICATOR
41782-01.pmd 6/7/05, 2:33 PM5
42995-01 6
Operation
Initial Operation
This section provides basic instructions on the use of your air purifier. After following these
initial directions, please continue reading this booklet to learn how to operate the more
advanced features of your air purifier.
Basic Operation of the Air Purifier:
1. Take the air purifier out of the box and remove the clear plastic protective bag.
Place the unit on a firm level floor.
2. Before turning on the air purifier, you need to confirm that the filters are firmly
in place and have not become loose during shipping. To check the filters, first
open the front grill. Release the front grill by placing your fingers under the
handle on the grill and pull forward, then up. Refer to Figs. 4 and 5.
Fig. 4
Fig. 5
3. Next, check the cleanable filter by pressing firmly on all four corners of the filter
to ensure that it is fully inserted into the filter opening.
4. The carbon pre-filter is mounted inside the front grill with hook tape. Confirm
that it properly covers the grill vents. You may notice a few black particles com-
ing off the pre-filter. Those particles are part of the odor-removing activated car-
bon and will be collected on the filter during use.
HANDLE
PULL
FORWARD,
THEN UP
41782-01.pmd 6/7/05, 2:33 PM6
7 42995-01
Operation
5. Place the front grill back onto the unit. First, line up the tab on the bottom of
the grill with the recess on the purifier base and then push the top of the grill
forward until it is closed. Refer to Figs. 6 and 7. NOTE: This unit will not
operate unless the grill is in the correct position.
Fig. 8
Fig. 6
Fig. 7
6. Plug the unit into a 120V electrical outlet and press the UP key. The air puri-
fier will start with a low blower speed.
7. Use the UP/DOWN keys to adjust the blower speed to the desired level (0 = Off,
1 = Sleep, 2 = Active, 3 = Turbo Clean). Refer to Fig. 8.
TAB
RECESS
LINE UP TAB WITH
RECESS IN BASE
41782-01.pmd 6/7/05, 2:33 PM7
42995-01 8
Operation
Filter Life Counters
The pre-filter and filter are critical to the proper operation of the air purifier. To help you
know when to clean or change the filters, your Hunter Air Purifier has Filter Life Counters
that will monitor the percentage of life your filter has left. Although the exact life of the
filters depends on the environment, the table below gives typical usage times of the filters.
Table 2: Typical Usage Times of the Filters
Filter Type Typical Usage
Activated Carbon Pre-Filter 1400 hours
Cleanable Filter 2800 hours
The display shows the percentage of life left since the counter was reset. NOTE: The per-
centage level drops in 5% increments.
The values of the Pre-Filter and Filter Life Counters are stored in the air purifier’s
memory. The unit may be unplugged and moved or stored without losing the Pre-
Filter and Filter Counter values.
To properly track filter usage, the Pre-Filter and Filter Life Counters should be reset each
time the filters are changed or cleaned. Refer to Changing the Pre-Filter (pg. 10) or Clean-
ing the Filter (pg. 11) for instructions on how to reset the counters.
Locking/Unlocking the Keypad
Once you enter the desired speed, you may want to lock the keypad to prevent accidental
changing of the speed. When the keypad is locked, all keys will be disabled. If you press a
key, the Keypad Locked Indicator will be displayed on the screen for 1-2 seconds.
To Lock or Unlock the Keypad:
1. To lock the keypad, press and hold the UP/DOWN keys
simultaneously for 2-3 seconds. The Keypad Locked In-
dicator will appear on the display. Refer to Fig. 9. After
releasing the keys, the Keypad Locked Indicator will dis-
appear.
2. To unlock the key pad, press and hold the UP/DOWN
keys simultaneously for 2-3 seconds. The Keypad Indi-
cator will disappear and the keypad will be functional.
Fig. 9
41782-01.pmd 6/7/05, 2:33 PM8
9 42995-01
Operation
Resetting the Air Purifier
In the unusual situation that the unit or the display is exhibiting erratic behavior, you may
want to reset the air purifier. If you still have problems after resetting the air purifier, please
contact Hunter for additional assistance (refer to Technical Assistance, pg. 14).
To Reset the Air Purifier:
1. Unplug the unit for at least 30 seconds.
2. Plug the unit back in.
Using the Ionizer
Using the ionizer improves the quality of air in the room. Negative ions are released into the
air and positively charged dust, smoke, and pollen particles are attracted to the negative
ions. These particles settle out of the air and can be vacuumed up during normal cleaning.
These particles are also more easily captured by the cleanable filter as they pass through the
PermaLife™ Cleanable Filtration System. To ensure the best air circulation in the room, we
recommend that you place your air purifier six (6) inches away from any walls.
To turn the ionizer on or off:
1. To turn the ionizer on, press the IONIZER key. The Ion-
izer Indicator will appear on the display. Refer to Fig 10.
2. To turn the ionizer off, press the IONIZER key. The Ion-
izer Indicator will disappear.
Controlling the Backlight
Your air purifier display has a backlight that is continuously lit as long as there is power to
the unit. The backlight may be turned off.
To turn the backlight off or on:
Press the PRE-FILTER RESET and FILTER RESET keys at the same time.
NOTE: Do not hold down the keys for longer than 2 seconds. This may reset a
filter counter.
and
Fig. 10
41782-01.pmd 6/7/05, 2:33 PM9
42995-01 10
Air Purifier Maintenance
Cleaning Your Air Purifier
Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free
service.
Follow these steps to properly maintain your air purifier:
1. Approximately every 90 days, the outside of the unit should be cleaned with a soft,
damp cloth.
2. If needed, the front grill can be removed from the unit and cleaned with soapy water.
Simply remove the pre-filter before exposing the grill to water.
3. Follow the instructions in Changing the Pre-Filter and Cleaning the Filter (pgs. 10 and
11) to determine when and how to replace or clean the filters.
NOTES:
•The air purifier must be unplugged during the cleaning process.
Be sure the unit is completely dry before plugging in and using.
•Never immerse unit in water.
Changing the Pre-Filter
When the Pre-Filter exceeds 1400 hours (refer to Filter Life Counters for additional infor-
mation, pg. 8), the Pre-Filter Life Counter will display 0% life remaining and the Pre-Filter
indicator will flash as a reminder that you should replace the pre-filter. To maintain proper
odor-removing capability and overall filtration performance, the pre-filter should be changed
every 1400 hours (approximately 3 months of use). If necessary, the pre-filter can be
changed more often. Proper maintenance of the pre-filter will help extend the life of the
cleanable filter. Refer to Obtaining Replacement Filters (pg. 13) if you need help find-
ing replacement filters.
To change the pre-filter and reset the Pre-Filter Life Counter:
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill. Place your fingers under the handle on the grill and pull
forward, then up. Refer to Figs. 4 and 5 (pg. 6).
3. The pre-filter is attached to the inside of the grill with hook tape. Pull gently on
the pre-filter to remove it. Refer to Fig. 11 (pg. 11).
4. If needed, use a soft damp cloth to wipe off the grill.
5. Install the new pre-filter by placing it in the grill and pressing gently on the pre-
filter so that it adheres to the hook tape. You may notice a few black particles
coming off the pre-filter. Those particles are part of the odor-removing activated
carbon and will be collected on the filter during regular use.
41782-01.pmd 6/7/05, 2:33 PM10
11 42995-01
Air Purifier Maintenance
Fig. 11
PRE-FILTER
HOOK
TAPE
HOOK
TAPE
6. Place the front grill back onto the unit. First, line up the tab on the bottom of
the grill with the recess on the purifier base and then push the top of the grill
forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: This unit will
not operate unless the grill is in the correct position.
7. Plug in the air purifier.
8. Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET
key for 2 seconds. The Pre-Filter Counter will return to 100% and the Pre-
Filter indicator will stop flashing.
Cleaning the Filter
The PermaLife™ Filtration System uses a cleanable filter that never has to be changed, only
cleaned. When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter
Life Counter will display 0% life remaining and the Filter indicator will flash (refer to Filter
Life Counters for additional information, pg. 8). This is a reminder that you should check
the filter and clean if necessary. The proper time to clean the filter depends on usage and the
environment. Use the following list to help determine if the filter should be cleaned:
Compare the color of the filter to the color coded chart on the inside of the housing. If the
filter color matches the darkest color on the chart, you should clean the filter.
If you notice a decrease in air output or an increase in noise at any time during normal
operation, the filter may be clogged. Clean the filter to return to normal operation.
To clean the filter and reset the Filter Life Counter:
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill. Place your fingers under the handle on the grill and pull
forward, then up. Refer to Figs. 4 and 5 (pg. 6).
Continued
41782-01.pmd 6/7/05, 2:33 PM11
42995-01 12
Air Purifier Maintenance
3. Gently pull on the filter to remove it from the unit. While removing the filter,
note the directional arrows printed on the top of the filter. The filter will be rein-
stalled with the same orientation. Refer to Fig. 12.
4. The label on the top side of the filter points to the side that should be cleaned.
Refer to Fig. 12. With a vacuum cleaner and upholstery brush attachment, clean
the filter until all particles are removed. Do not use water or liquids to clean.
5. Install the filter with arrows pointing towards the unit. Refer to Fig. 12. Press
the filter firmly into the air purifier. To avoid damaging the filter media, you
should press on the frame of the filter only.
6. Place the front grill back onto the unit. First, line up the tab on the bottom of
the grill with the recess on the purifier base and then push the top of the grill
forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: This unit will
not operate unless the grill is in the correct position.
7. Plug in the unit.
8. To reset the filter counter, press the FILTER RESET key for 2 seconds. The Filter
Counter will return to 100% and the Filter indicator will stop flashing.
Fig. 12
REINSTALL FILTER WITH AIRFLOW DIRECTION
ARROWS POINTING TOWARD UNIT.
CLEAN/VACUUM THIS
SIDE OF FILTER
Filter Label
41782-01.pmd 6/7/05, 2:33 PM12
13 42995-01
Air Purifier Maintenance
Obtaining Replacement Filters
To obtain replacement filters for your air purifier, first determine your model number
by looking at the information label on the back of the air purifier. The model number
will be listed on the label. Then, call 1-800-4HUNTER for your nearest retailer or Hunter
Customer Service at 1-800-313-3326 (CAN 1-866-268-1936) to order directly. To or-
der online, visit our Website at www.hunterfan.com. To ensure that you obtain the cor-
rect filters, please find your model number below that specifies the correct replacement
filters.
Hunter Air Purifier Model No.: .......................... 30750
Pre-Filter Replacement Model No.: ................... 30901
41782-01.pmd 6/7/05, 2:33 PM13
42995-01 14
Troubleshooting
Technical Support
If you have any additional questions or problems with your Hunter air purifier, please
call 1-888-830-1326 from 8:00 am to 5:00 pm Central Time or contact us over the Internet
at www.hunterfan.com.
1. No display or operation.
2. Keypad does not work.
3. Erratic Display or
Operation.
4. Filter and/or Pre-filter
Indicator is Flashing.
5. Cleanable Filter and/or
Carbon Pre-Filter Life
Counter is flashing 0%.
6. Unit has reduced air flow
or increased noise.
Problem Solutions
Confirm that the unit is plugged in.
Check the installation of the front grill.
Reset the air purifier. (See Resetting the Air Purifier
on pg. 9.)
•Key pad has been locked to prevent accidental changes
to the programs. (See Keypad Lock on pg. 8 to unlock
the key pad.)
Reset the air purifier. (See Resetting the Air Purifier
on pg. 9.)
•The Filter and/or Pre-Filter Life Counters have reached the
estimated usage times. Check and replace or clean filters if
needed. (Refer to Filter and Pre-Filter Counters on pg. 8.)
•The Filter and/or Pre-Filter Life Counters have greatly
exceeded the estimated usage times. Replace or clean the
corresponding filters.
•The filter is clogged and should be cleaned. (Refer to
Cleaning the Filter on pg. 11.)
41782-01.pmd 6/7/05, 2:33 PM14
15 42995-01
Warranty
Hunter Fan Company
PermaLife
Air Purifier
5 YEAR LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original residential
user or consumer purchaser of the PermaLife
Air Purifier:
If any part of your PermaLife
Air Purifier motor or control panel fails during the first five
(5) years from the date of installation due to a defect in material or workmanship, we will
provide a replacement Air Purifier free of charge. Installation is deemed to occur at the date
of purchase.
If the Air Purifier cord or front grill fails any time within one (1) year after installation due
to a defect in material or workmanship, we will replace or, at our option, repair the unit free
of charge at our nearest service center or at our Service Department in Memphis, Tennessee.
You will be responsible for all parts and labor costs after this one-year period.
USE OF A NON-HUNTER FILTER WILL INVALIDATE THIS WARRANTY. IF THE
ORIGINAL RESIDENTIAL USER OR CONSUMER PURCHASER CEASES TO OWN
THE AIR PURIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH
THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,
ARE VOIDED.
NO WARRANTY, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN
RESPECT TO THE FILTER MATERIAL OR CARBON FILTER.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DU-
RATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PERIOD
OF THE EXPRESS WARRANTY SET FORTH ABOVE.
This warranty is voided if the air purifier is not purchased and used in the USA or Canada.
This warranty excludes and does not cover defects, malfunctions or failures of the Air Puri-
fier which were caused by repairs by persons not authorized by us, use of parts or accesso-
ries not authorized by us, mishandling, modifications, or damage to the Air Purifier while in
your possession, or unreasonable use, including failure to provide reasonable and necessary
maintenance. This warranty does not cover Air Purifiers used in commercial applications.
There are no express or implied warranties as to commercial purchasers or users.
To obtain service, contact the nearest Hunter authorized service center or the Hunter Fan
Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114, 1-888-
830-1326. For the name of our nearest authorized Hunter Fan Company Service Center,
Continued
41782-01.pmd 6/7/05, 2:33 PM15
42995-01 16
Warranty
write to the Hunter Fan Company at the preceding address. You will be responsible for
insurance and freight or other transportation to our factory service center. We will return the
Air Purifier freight prepaid. The Air Purifier should be properly packaged to avoid damage
in transit since we will not be responsible for any such damage. Proof of purchase is re-
quired when requesting warranty service. The purchaser must present sales receipt or other
document that establishes proof of purchase.
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT, INDI-
RECT, SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF
THE PURCHASE PRICE OF THE AIR PURIFIER. YOUR SOLE REMEDY WILL BE
REPAIR OR REPLACEMENT AS PROVIDED ABOVE.
SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW:
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS;
THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT SPECIAL, INCI-
DENTAL OR CONSEQUENTIAL DAMAGES;
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO
PROVINCE.
41782-01.pmd 6/7/05, 2:33 PM16
To learn more about Hunter Fan Company products, please see our Web page at:
www.hunterfan.com
Other Home Comfort Products from Hunter
The Care-Free
Humidifier
Programmable
Thermostat
®
Hunter Original
®
Fans
HUNTER FAN COMPANY
2500 FRISCO AVENUE
MEMPHIS, TN 38114, USA
®
42995-01
Printed in China and Taiwan
M
AM
4
TEMP
41782-01.pmd 6/7/05, 2:33 PM17
www.hunterfan.com
Modèle 30750
42995-05 05/08/2006 © 2006 Hunter Fan Company
Informations sur le remplacement du filtre
Modèle
30750
Pré-filtre
30901
41782-05.pmd 6/7/05, 2:34 PM1
42995-05 2
Table des matières
Instructions de sécurité ..........................................................................................3
Introduction ............................................................................................................3
Description du système de filtration de l’air
Comment fonctionne le purificateur d’air......................................................4
Composants du purificateur d’air...................................................................4
Afficheur et touches de commande ................................................................ 5
Fonctionnement
Utilisation initiale ...........................................................................................6
Compteurs de durée de vie du filtre ...............................................................8
Verrouiller/déverrouiller le clavier .................................................................8
Réinitialiser le purificateur d’air ....................................................................9
Utiliser le ioniseur ..........................................................................................9
Contrôler le rétro éclairage.............................................................................9
Entretien du purificateur d’air
Nettoyer votre purificateur d’air ..................................................................10
Changer le pré-filtre ..................................................................................... 10
Nettoyer la filtre ...........................................................................................11
Obtenir des filtres de remplacement ............................................................ 13
Dépannage
Problèmes et solutions..................................................................................14
Soutien technique .........................................................................................14
Information sur la garantie .................................................................................15
41782-05.pmd 6/7/05, 2:34 PM2
3 42995-05
INSTRUCTIONS DE SÉCURITÉ
IMPORTANT !
LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER CE PURIFICATEUR D’AIR.
1. Ce purificateur d’air est conçu pour une utilisation sur un sol au niveau et pourrait ne pas fonc-
tionner adéquatement sur une surface inégale.
Placez TOUJOURS ce purificateur d’air sur une surface dure et de niveau. Placez TOUJOURS
ce purificateur d’air à un minimum de quinze (15) cm (6 pouces) des murs et sources de chaleur
comme les poêles, radiateurs ou calorifères.
2. Placez le purificateur d’air dans un endroit où il sera hors de portée des enfants.
3. Avant d’utiliser le purificateur d’air, déroulez son cordon et inspectez-le pour y repérer d’éven-
tuels signes de dommage. N’utilisez PAS ce produit si le cordon est endommagé.
4. Ce produit est muni d’une prise polarisée (une broche est plus large que l’autre) comme disposi-
tif de sécurité. Cette prise s’adaptera à une sortie électrique polarisée d’une seule façon. Si la
prise ne s’adapte pas parfaitement à la sortie électrique, inversez-la. Si elle ne s’adapte tou-
jours pas, consultez un électricien qualifié. N’essayez PAS de contourner ou de déjouer
cette option de sécurité.
5. DÉBRANCHEZ TOUJOURS le purificateur d’air lors de son nettoyage.
6. Ne déplacez PAS et n’inclinez pas le purificateur d’air lorsqu’il est en fonction. Éteignez et
débranchez avant de déplacer.
7. N’IMMERGEZ PAS le purificateur d’air car cela provoquerait des dommages permanents. Pour
nettoyer adéquatement votre purificateur d’air, suivez les instructions de la section Entretien de
ce manuel (page 10).
LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS.
Introduction
Merci d’avoir acheté le purificateur d’air PermaLife
de Hunter Fan Company. Vous venez de vous
procurer les développements les plus récents en matière de système portatif de purification de l’air,
conçu pour améliorer la qualité de l’air que vous respirez. Les options novatrices suivantes sont offer-
tes avec votre purificateur d’air Hunter.
Haute efficacité pour les particules : le filtre lavable supprimera 99,5% de 0,5 microns de parti-
cules de l’air qui passe à travers le filtre.
Suppression des odeurs : le pré-filtre au charbon actif aide à supprimer les odeurs de cuisine, la
fumée et les odeurs d’animaux. Il emprisonne également la peluche, les cheveux et les autres
grosses particules pour accroître la durée de vie et la performance du filtre lavable.
Ioniseur : le ioniseur améliore la qualité de l’air de la pièce en libérant des ions négatifs dans l’air
; ces ions attirent la poussière, la fumée et les particules de pollen positivement chargées.
Silencieux : le purificateur d’air a été conçu pour fonctionner silencieusement et efficacement.
Vous pouvez choisir parmi trois vitesses pour mieux combler vos besoins selon les moments.
Compteurs de filtre : l’entretien du filtre est essentiel à la performance du purificateur d’air. Pour
vous aider à déterminer le moment où changer ou nettoyer le pré-filtre et le filtre lavable, l’appa-
reil possède des compteurs intégrés qui font un suivi de la durée de vie restante de chaque filtre.
Lumière NiteGlo™ : l’afficheur de votre purificateur d’air possède un rétro éclairage allumé
en continu aussi longtemps que l’appareil est alimenté. Vous avez le choix de l’éteindre ou de
l’allumer.
41782-05.pmd 6/7/05, 2:34 PM3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Hunter PERMALIFE 30750 Le manuel du propriétaire

Catégorie
Purificateurs d'air
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues