red lion N-Tron 1005TX Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur
N-Tron
®
1000 Series
Industrial Gigabit Media Converters
& Gigabit Ethernet Switches
Hardware Guide | March 2015
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
COPYRIGHT
Copyright, © 2015 Red Lion Controls, Inc.
20 Willow Springs Circle
York, PA 17406
All rights reserved. Red Lion, the Red Lion logo and N-Tron are registered trademarks of Red Lion Controls,
Inc. All other company and product names are trademarks of their respective owners.
The information contained in this document is subject to change without notice. Red Lion makes no warranty
of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability
or fitness for a particular purpose. In no event shall Red Lion be liable for any incidental, special, indirect or
consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions
in this manual or the information contained herein.
CONTACT INFORMATION :
AMERICAS
York, PA: +1 (717) 767-6511
Mobile, AL: +1 (251) 342-2164
Ballston Lake, NY: +1 (518) 877-5173
Hours: 8am-6pm Eastern Standard Time
(UTC/GMT -5 hours)
ASIA-PACIFIC
Shanghai, P.R. China: +86 21-6113-3688 x767
Hours: 10am-6pm China Standard Time
(UTC/GMT +8 hours)
EUROPE
The Netherlands: +31 33-4723-225
Hours: 9am-6pm Central European Time
(UTC/GMT +1 hour)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide i
Table of Contents Revised 2015-03-24
Table of Contents
Preface
Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference . . . . . . iii
Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Environmental Impact Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Toxic Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Trademark Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Release Notes and Document Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Publication History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Document Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Additional Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
General Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Electrical Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Environmental Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Hazardous Location Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Laser Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Introduction and Specifications
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Product Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Model 1002MC Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Model 1002MC Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Model 1003GX2 - Key Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Model 1003GX2 Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
Table of Contents Revised 2015-03-24
ii N-Tron 1000 Series Hardware Guide
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Model 1005TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Model 1005TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Model 1008TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Model 1008TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Installing/Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
DIN-Rail Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Power Connection (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Ground Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
N-Tron Series Switch Grounding Techniques for 1000 Series . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Operation and Maintenance
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Model 1002MC, 1003GX2, 1005TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Model 1008TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Verify/Troubleshoot Cable Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Red Lion Controls N-Tron 1000 Series Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide iii
Preface Revised 2015-03-24
Preface
Disclaimer
Portions of this document are intended solely as an outline of methodologies to be followed during the
maintenance and operation of N-Tron 1000 Series equipment. It is not intended as a step-by-step guide or a
complete set of all procedures necessary and sufficient to complete all operations.
While every effort has been made to ensure that this document is complete and accurate at the time of release, the
information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or
alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic
conditions. This document is intended as a general guide only. It has not been tested for all possible applications,
and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as
electrical hazard warnings.
Compliance Information
It is recommended that the owner of this equipment determine and ensure conformance with any specific and
applicable local regulations.
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference
Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital
device, as described in the FCC Rules.
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful Interference
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Operation of this device in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at their own expense.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des
règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas
causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris
l'interférence qui peut causer l'opération peu désirée.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
Preface Revised 2015-03-24
iv N-Tron 1000 Series Hardware Guide
Environmental Impact Statement
Red Lion equipment contains no hazardous materials as defined by the United States Environmental Protection
Agency (USEPA). Red Lion recommends that all failed product be returned to Red Lion for failure analysis and
proper disposal.
Toxic Emissions
Red Lion equipment releases no toxic emissions.
Trademark Acknowledgments
Ethernet is a registered trademark of Xerox Corporation.
EtherNet/IP
TM
and CIP
TM
are registered trademarks of ODVA.
Release Notes and Document Updates
The hard copy and electronic media versions of this document are revised only at major releases and therefore,
may not always contain the latest product information. As needed, Documentation Notes and or Product Bulletins
will be provided between major releases to describe any new information or document changes.
The latest online version of this document and all product updates can be accessed through the Red Lion web
site.
Publication History
The following information lists the release history of this document.
Related Documents
Visit the Technical Resources page on the Red Lion website at the following link to view available documents
related to this product.
Document Comments
Red Lion appreciates all comments that will help us to improve our documentation quality. The user can
submit comments through the Red Lion Customer Service. Simply email us.
Additional Product Information
Additional product information can be obtained by contacting the local sales representative or Red Lion through the
contact numbers and/or e-mail addresses listed on the inside of the front cover.
ISSUE/REVISION RELEASE DATE CONTENT DESCRIPTION
Revised 2014-01-23 January 2014 Document Updates
Revised 2015-03-17 March 2015 Added 1008TX Model, Format Changes
Revised 2015-03-24 March 2015 Format Changes to Cover, Page Header and Tables
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide v
Preface Revised 2015-03-24
Warnings and Cautions
Warnings apply to situations where personal injury or death may result.
Cautions apply to where reduced function or damage to equipment may result.
General Safety Cautions and Warnings
Electrical Safety Warnings
CAUTION: If the N-Tron series equipment is used in the manner not specified by Red Lion, the
protection provided by the equipment may be impaired.
ATTENTION: Si l' N-Tron série équipement est utilisé d'une manière non spécifiée par Red Lion,
la protection fournie par l'équipement peut être compromise.
CAUTION: Do not perform any services on the unit unless qualified to do so. Do not substitute
unauthorized parts or make unauthorized modifications to the unit.
ATTENTION: Ne pas effectuer de services sur l'appareil s'il n'est pas qualifié pour le faire. Ne pas
substituer pièces non autorisées ou de modifications non autorisées de l'appareil.
CAUTION: Do not operate the equipment in a manner not specified by this manual.
ATTENTION: Ne pas faire fonctionner l'équipement d'une manière non spécifiée par ce manuel.
WARNING: Install only in accordance with Local and National Codes of authorities having
jurisdiction.
ALERTE: Installer uniquement, conformément aux codes locaux et nationaux des autorités ayant
compétence.
WARNING: Do not work on equipment or cables during periods of lightning activity.
ALERTE: Ne pas travailler sur le matériel ou les câbles pendant les périodes d'activité de la
foudre.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
Preface Revised 2015-03-24
vi N-Tron 1000 Series Hardware Guide
WARNING: Properly ground the unit before connecting anything else to the unit. Units not
properly grounded may result in a safety risk and could be hazardous and may void the warranty.
See the grounding technique section of this Hardware Guide for proper ways to ground the unit.
ALERTE: Correctement à la terre de l'unité avant tout raccordement à l'unité. Unités pas
correctement mise à la terre peut entraîner un risque de sécurité et pourraient être dangereux et
peut annuler la garantie. Voir la section technique de mise à la terre de ce mode d'emploi des
moyens appropriés à la masse de l'appareil.
WARNING: This equipment must be used with a Listed UL Industrial Power Supply.
ALERTE: Cet équipement doit être utilisé avec une alimentation UL Listed industrielle.
WARNING: This equipment (1005TX and 1008TX) must be used with a Listed UL Class 2 Power
Supply.
ALERTE: Cet équipement (1005TX and 1008TX) doit être utilisé avec une alimentation UL Listed
Classe 2.
WARNING: A Recognized or Listed fuse, rated maximum 3A, minimum 30VDC, must be installed
on the line side of the device.
ALERTE: Un fusible reconnu ou classé, classé 3A maximale, 30VDC minimum, doit être installé
sur le côté de la ligne de l'appareil.
WARNING: Use 110°C or higher rated copper wire, (0.22Nm) 2 lb/in tightening torque for field
installed conductors.
ALERTE: Utilisez 110°C ou nominale supérieure fil de cuivre, (0,22 Nm) 2 lb/pouce couple de
serrage pour le champ installé conducteurs.
WARNING: Do not operate the unit with the end plates removed, as this could create a shock or
fire hazard.
ALERTE : Ne pas faire fonctionner l'unité avec les plaques d'extrémité retiré, ce qui pourrait créer
une décharge électrique ou un incendie.
CAUTION: Observe proper DC Voltage polarity when installing power input cables. Reversing
voltage polarity can cause permanent damage to the unit and voids the warranty.
ATTENTION: Respecter la polarité correcte de tension DC lors de l'installation des câbles
d'alimentation d'entrée. Inversion de polarité de tension peut causer des dommages permanents à
l'appareil et annule la garantie.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide vii
Preface Revised 2015-03-24
Environmental Safety Cautions and Warnings
Hazardous Location Warning
CAUTION: This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or
non-hazardous locations only.
ATTENTION: Cet équipement est adapté pour une utilisation dans la classe I, Division 2, Groupes
A, B, C et D ou non dangereux endroits seulement.
WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I,
Division 2.
ALERTE - Risque d'explosion - Remplacement d'un composant peut empêcher la conformité de
Classe I, Division 2.
WARNING: Do not operate the equipment in the presence of flammable gases or fumes. Operat-
ing electrical equipment in such an environment constitutes a definite safety hazard.
ALERTE : Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation
de matériel électrique dans un tel environnement constitue un danger certain.
WARNING – Explosion Hazard – Do not connect or disconnect any connections while circuit is
live unless area is known to be non-hazardous.
ALERTE - Risque d'explosion - Ne pas brancher ou débrancher les connexions lorsque le circuit
est sous tension sauf si la zone est connue pour être non dangereux.
WARNING: Disconnect the power and allow to cool 5 minutes before touching.
ALERTE: Déconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la toucher.
WARNING (1005TX and 1008TX only): This equipment is open-type device and is meant to be
installed in an enclosure suitable for the environment that is only accessible with the use of a tool.
ALERTE (1005TX and 1008TX uniquement): Cet équipement est ouvert de type périphérique et
est destiné à être installé dans un boîtier adapté à l'environnement qui n'est accessible qu'avec
l'utilisation d'un outil.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
Preface Revised 2015-03-24
viii N-Tron 1000 Series Hardware Guide
Laser Safety Warning
CAUTION (1002MC and 1003GX2 only): CLASS 1 LASER PRODUCT. Do not stare into the
laser.
ATTENTION (1002MC et 1003GX2 uniquement): PRODUIT LASER CLASSE 1. Ne pas regarder
dans le laser.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-1
Introduction and Specifications Revised 2015-03-24
Section 1 Introduction and Specifications
Introduction
The N-Tron 1000 Series Unmanaged Industrial Gigabit Ethernet Switches support high speed layer 2 switching
between ports. This series of switches are housed in a ruggedized aluminum enclosure, and provide Category-5
compliant 10/100/1000Base-T connections for high performance network design, and hub/repeater upgrades.
All fiber products utilize the IEEE compliant LC duplex connectors for fiber optic communications in a convenient
SFP (Small Form Pluggable) modular design. All 10/100/1000Base-T ports utilize the RJ45 shielded connectors.
The 1002MC/MCE is a two port unmanaged media converter that converts 10/100/1000Base-T copper to
1000BaseSX/LX full duplex fiber.
The 1003GX2/GXE2 is a three port unmanaged switch that offers one 10/100/1000Base-T copper port and two
1000BaseT/SX/LX full duplex copper/fiber ports.
The 1005TX is a five port unmanaged switch that offers five 10/100/1000Base-T copper ports.
The 1008TX is an eight port unmanaged switch that offers eight 10/100/1000Base-T copper ports.
Key Features
Compact Space Saving Package
Full IEEE 802.3 Compliance
Unmanaged Operation
Jumbo Frame Support (1005TX and 1008TX only)
Extended Environmental Specifications
-40°C to 85°C Operating and Storage Temperature
Supports Full/Half Duplex Operation
Up to 16.0 Gb/s Maximum Throughput
MDIX Auto Sensing Cable
Auto Sensing Speed and Flow Control
Full Wire Speed Communication
Store-and-Forward Switching Technology
Redundant Power Inputs (10-30 VDC, 10-49VDC for 1008TX)
LED Link/Activity Status Indication
Hardened Metal Enclosure
Industry Standard 35mm DIN Rail Mounted Enclosure
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-2
Introduction and Specifications Revised 2015-03-24
Product Ordering Guide
The 1000 Series Media Converter and Unmanaged Industrial Gigabit Ethernet Switch model part numbers and net-
work applications are presented in Table 1.
Table 1. Ordering Guide
Where: “YY” or “ZZ” is: 10 for 10km maximum fiber segment length
40 for 40km maximum fiber segment length
80 for 80km maximum fiber segment length
PART NUMBER APPLICATION
1002MC-SX 1000BaseSX Multimode fiber Media Converter
1002MC-LX-YY 1000BaseLX Singlemode fiber Media Converter
1003GX2 Three port; One 10/100/100BaseT; Two 1000BaseSX/LX Gigabit Ethernet Switch
1003GX2-B One 10/100/1000BaseT port; Two 1000BaseSX/LX ports with mix-and-match SFP Mini-GBIC
fiber transceivers. Note: Unit must be populated with two SFP transceivers upon shipment
1003GX2-SX One 10/100/1000BaseT port; Two (2) 1000BaseSX SFP Mini-GBIC fiber transceivers
1003GX2-LX-10 One 10/100/1000BaseT port; Two (2) 1000BaseLX-10 SFP transceivers
1003GX2-LX-40 One 10/100/1000BaseT port; Two (2) 1000BaseLX-40 SFP transceivers
1003GX2-LX-80 One 10/100/1000BaseT port; Two (2) 1000BaseLX-80 SFP transceivers
1005TX Five port 10/100/1000BaseT Gigabit Ethernet switch
1008TX Eight port 10/100/1000BaseT Gigabit Ethernet switch
NTSFP-SX One 1000BaseSX Multimode SFP Gigabit Transceiver with LC Style Connector for up to
550m fiber segment length (two required per unit)
NTSFP-LX-ZZ One 1000BaseLX Singlemode SFP Gigabit Transceiver with LC Style Connector for up to ZZ
fiber segment length (two required per unit)
NTPS-24-1.3 DIN-Rail Power Supply [email protected] amp; Used with all models
1000-PM Panel Mount kit; Used with all models
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-3
Introduction and Specifications Revised 2015-03-24
Model 1002MC Key Specifications
Table 2. 1002MC - Key Specifications
Table 3. Gigabit Fiber Transceiver SFP Characteristics
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC
(Steady State)
Depth w/ typical SFP installed 3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @
24VDC
Weight 0.70 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
(Non Condensing)
1000BaseT Cat-5e
Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125m
1000BaseLX Singlemode 7-10/125m
CONNECTOR RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)
1000Base-X SFP One (1) SFP LC Duplex
Gigabit Fiber Port
Front 4 " (10.16 cm)
NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80
FIBER LENGTH
550m with 50/125m
275m @ 62.5/125m
10km 40km 80km
TX POWER MIN
-9.5dBm -9.5dBm -2dBm 0dBm
RX SENSITIVITY MAX
-17dBm -20dBm -22dBm -24dBm
WAVELENGTH
850nm 1310nm 1310nm 1550nm
ASSUMED FIBER LOSS
3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km
LASER TYPE
VCSEL FP DFB DFB
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-4
Introduction and Specifications Revised 2015-03-24
Model 1002MC Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4A.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-5
Introduction and Specifications Revised 2015-03-24
Model 1003GX2 - Key Specifications
Table 4. 1003GX2 Key Specifications
Table 5. Gigabit Fiber Transceiver (SFP) Characteristics
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC
(Steady State)
Depth w/ typical
SFP installed
3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @
24VDC
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
(Non Condensing)
1000BaseT Cat-5e
Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125m
1000BaseLX Singlemode 7-10/125m
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)
1000Base-X SFP Up to two (2) SFP LC Duplex
Gigabit Fiber Ports
Front 4 " (10.16 cm)
NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80
FIBER LENGTH
550m with 50/125m
275m @ 62.5/125m
10km 40km 80km
TX POWER MIN
-9.5dBm -9.5dBm -2dBm 0dBm
RX SENSITIVITY MAX
-17dBm -20dBm -22dBm -24dBm
WAVELENGTH
850nm 1310nm 1310nm 1550nm
ASSUMED FIBER LOSS
3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km
LASER TYPE
VCSEL FP DFB DFB
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-6
Introduction and Specifications Revised 2015-03-24
Model 1003GX2 Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4A.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-7
Introduction and Specifications Revised 2015-03-24
Model 1005TX - Key Specifications
Table 6. 1005TX Key Specifications
Model 1005TX Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 230mA max. @ 24VDC
(Steady State)
Depth w/ typical
SFP installed
3.61” (9.165 cm) Inrush Current 13 Amp/0.61 ms max. @
24VDC
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
(Non Condensing)
1000BaseT Cat-5e
Operating Altitude 0 to 10,000 ft.
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX Five (5) RJ45 TX Copper
Ports
Top 1 " (2.54 cm)
Front 2 " (5.08 cm)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-8
Introduction and Specifications Revised 2015-03-24
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-9
Introduction and Specifications Revised 2015-03-24
Model 1008TX - Key Specifications
Table 7. 1008TX Key Specifications
Model 1008TX Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2013 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous (Classi-
fied) Locations Groups A, B, C, D. T4.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
FCC Title 47, Part 15, Subpart B - Class A
Industry Canada ICES-003 – Class A
EN 55011 - Class A
EN 61000-6-4
EN 61000-3-2/3
PHYSICAL ELECTRICAL
Height 4.63” (11.76 cm) Input Voltage 10-49 VDC (Regulated)
Width 1.55” (3.94 cm) Input Current 290mA max. @ 24VDC
(Steady State)
Depth w/ typical
SFP installed
4.08” (10.37 cm) Inrush Current 20 Amp/0.06 ms max. @
24VDC
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%(Non Condens-
ing)
1000BaseT Cat-5e
Operating Altitude 0 to 10,000 ft.
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX Eight (8) RJ45 TX Copper
Ports
Top 1 " (2.54 cm)
Front 2 " (5.08 cm)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
N-Tron 1000 Series Hardware Guide 1-10
Introduction and Specifications Revised 2015-03-24
EMS
EN 61000-6-2
EN 61000-4-2/3/4/5/6/8/11
Warranty
3 years from the date of purchase.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

red lion N-Tron 1005TX Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur

dans d''autres langues