DutchWest DW2500X02 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire
EPA Certified High Efficiency
Wood Insert
Model DW2500X02
Owners Manual
SAFETY NOTICE
Read this entire manual before you install and use your fireplace insert. If not properly in-
stalled, a house fire may result. To reduce the risk of fire, follow the installation instructions.
Failure to follow instructions may result in property damage, bodily injury or even death. Con-
tact local building, fire officials or authorities having jurisdiction about permits, restrictions
and installation inspection requirements in your area.
This unit is not mobile home approved.
Do Not Discard This Manual: Retain for Future Use
This appliance is manufactured for a 6” (152 mm) Dia.
chimney connection. (Refer to Page 7)
30004581 1/09 Rev. 2
DUTCHWEST
4581
DW2500X02 cover
10/08
2
DW2500X02
30004581
CAUTION
After reading these instructions, if you have any doubt
about your ability to complete your installation in a
professional like manner you should obtain the services
of an installer versed in all aspects as to the correct
and safe installation. Do not use temporary makeshift
compromises during installation.
About Your Appliance
1. Hot while in operation. Keep children, clothing and
furniture away. Contact may cause skin burns.
2. Do not burn garbage or flammable fluids.
3. Check with the building inspector’s office for com-
pliance with local codes; a permit may be required.
4. This appliance requires installation in a masonry
type fireplace only. DO NOT INSTALL IN A FACTO-
RY BUILT FIREPLACE SUCH AS A ZERO CLEAR-
ANCE.
5. Always connect this unit to a chimney and NEVER
vent to another room or inside a building.
6. Do not connect to any air distribution duct or sys-
tem.
7. Do not connect this unit to a chimney flue serving
another appliance.
8. A stainless steel chimney liner may be required.
Check with local building, fire officials or authorities
having jurisdiction in your area.
9. Do not use chemicals or fluids to start the fire.
10. The connector pipe and chimney should be inspect-
ed periodically and cleaned if necessary.
11. Remember the clearance distances when you place
furniture or other objects within the area. DO NOT
store wood, flammable liquids or other combustible
materials too close to the unit.
12. Contact your local municipal or provincial fire
authority for information on how to handle a chim-
ney fire. Have a clearly understood plan to handle
a chimney fire. In the event of a chimney fire, turn
air control to closed position and CALL THE FIRE
DEPARTMENT.
13. DO NOT tamper with air control beyond normal
adjustment.
14. Once the required draw is obtained, operate only
with doors closed and open door slowly when re-
fueling. (This will reduce or eliminate smoke from
entering the room). These units are not mobile
home approved. Do not install this unit in a mobile
home or trailer.
Why the correct chimney size is important
Your appliance operates best using a minimum 6” (152
mm) diameter chimney. The maximum chimney diam-
eter must not exceed 10” (254 mm) in diameter or have
a cross sectional area greater than 85 in
2
(550 cm
2
).
Today’s solid fuel appliances are much more efficient
than in the past. The units are designed to give you
controlled combustion, as well as maximum heat
transfer, using less fuel to do so. The result of better
heat transfer is lower chimney temperatures, making
the chimney size important for good draft. Poor draft
will create poor performance of your appliance, and a
safety hazard.
Should you experience a problem with smoke en-
tering the room or poor combustion, call in a local
chimney expert.
Burn Rate
With the door closed, the rate of burning is regulated by
the amount of air allowed to enter the unit through the
air control. With experience you will be able to set the
control for the desired heat and burning time.
Attempts to achieve higher output rates that exceed
heater design specifications can result in permanent
damage to the heater. The recommended wood load
is level with the top of the firebricks. Overloading may
prevent sufficient air entering the heater to properly fuel
the fire.
DO NOT tamper with air control beyond the normal
adjustment capacity.
WARNING: Operate this heater only with the door
closed.
THIS HEATER IS EXTREMELY HOT WHILE IN OP-
ERATION.
SERIOUS BURNS CAN RESULT FROM CONTACT.
KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY.
ALWAYS PROVIDE A SOURCE OF FRESH AIR
INTO THE ROOM WHERE THE UNIT IS INSTALLED.
FAILURE TO DO SO MAY RESULT IN AIR STARVA-
TION OF OTHER FUEL BURNING APPLIANCES
AND THE POSSIBLE DEVELOPMENT OF HAZ-
ARDOUS CONDITIONS.
Proposition 65 Warning:
Fuels used in gas, wood-
burning or oil fired appliances, and the products of
combustion of such fuels, contain chemicals known
to the State of California to cause cancer, birth de-
fects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
3
DW2500X02
30004581
Specifications
Model DW2500X02 non-catalytic wood heater. This heater meets US Environmental Protection Agency’s emission
limits for wood heaters. Under specific conditions this heater has been shown to deliver heat at rates ranging from
9,500 to 58,000 BTU per hour.
Model DW2500X02 is listed by OMNI-Test Laboratories of Portland, OR and meets UL 1482 for the US and ULC S
627-00 for Canada.
44” (1118 mm)
31”
(787 mm)
9
(235 mm)
20” (527 mm)
*
16
(413 mm)
10”
(254 mm)
16”
(406 mm)
26” (679 mm)
8
(225 mm)
21
(553 mm)
4581
DW2500X02 dims
10/08
* Adjustable 10” (254 mm) to 14” (356 mm)
NOTE: Refer to Pages 4 and 5 for clearances and floor
protection information.
Figure 1
DW2500X02 Dimensions
4
DW2500X02
30004581
Clearance to Combustible Constructions
1. Remove all boxes of firebricks and any packaging
from inside the appliance.
2. Clean out the masonry fireplace ensuring the ashes
are placed in a metal container.
3. Remove or lock open the damper plate in the ma-
sonry fireplace.
4. Contact local building, fire officials or authorities
having jurisdiction about permits, restrictions and
installation inspection requirements in your area.
5. The insert must be installed in compliance with the
minimum clearances to combustible constructions
and floor protection stated on appliance certifica-
tions label (located on back of unit) and listed below.
Installation
A
B
C
D
E
F
ST1022
DW2500 clearances
10/08
Refer to Page 5 for further instructions about floor
protection.
FAILURE TO FOLLOW THESE MINIMUM CLEAR-
ANCES REQUIREMENTS MAY RESULT IN AN UN-
SAFE INSTALLATION.
6. Install the refractory bricks. (Fig. 3)
7. Install faceplate onto insert. (Page 7) The trim
should fit against the face of the fireplace. If this is
not a good fit, a 2” (51 mm) wide strip of fiberglass
insulation can be used to insure a good fit.
Mantel
Top Trim
Face Plate
Floor Protector
Side Wall
Side Trim
Floor
12”
(305 mm)
Max
ST1022
Clearance to Combustible Constructions
A Unit to Side Wall 12” (305 mm)
B Unit to Top Trim 10” (254 mm)
C Unit to Side Trim 10” (254 mm)
D Unit to Mantel 17” (430 mm)
E Floor Protector Front 16” (405 mm) in the US
18” (457 mm) in Canada
F Floor Protector Side 8” (203 mm)
Refer to Page 6 for Floor Protection requirements
Figure 2
Clearance to Combustibles
5
DW2500X02
30004581
Floor Protection
This appliance must be installed in a masonry fireplace
enclosure built in accordance
with local building codes. DO
NOT INSTALL IN A FACTORY
BUILT FIREPLACE SUCH AS A
ZERO CLEARANCE.
Floor protector must extend to
cover area shown on the diagram
below.
When the floor covering the area
shown is concrete, no floor pro-
tector is required.
Carpeting and any other combus-
tible material shall not cover the
floor protector.
If a combustible surface is applied to the concrete floor,
a clearance must be maintained equivalent to the area
reserved for the floor protector. (Fig. 4)
If the area shown is a combustible floor or a combusti
-
ble floor covering, a 3/8” (10 mm) thick noncombustible
millboard floor protector or durable equivalent must be
installed. The pad must cover the area shown.
A grouted ceramic floor tile surface installed per local
building code is considered a durable equivalent.



8” (203 mm)
16” (406 mm) in the US
18” (457 mm) in Canada
8” (203 mm)
Face
Plate
Floor Protector
Door Side of
Appliance
ST1023
Figure 4
Floor Protector
Faceplate Assembly
Refer to Figure 5
1. Assemble top (#1) to sides (#2) using #8 x 1/2” Tek
screws (#9).
2. Attach the side right and left trims (#5,6) to sides
(#2) using #8 brass screws.
3. Attach top right and left trims (#3,4) together with the
articulating angles (#8).
4. Install corner brackets (#7) to top trim.
5. Attach top trim to face plate placing corner brackets
into side trim and tightening screws in the corner
brackets to secure.
Face Plate Installation
1. Hook one end of spring (#10) into hole on stove top.
2. Hook the other end of the spring through the 1/8” (3
mm) hole in the faceplate top. (Fig. 6)
3. Slide the face plate against the masonry wall. NOTE:
Use the installation bulletin supplied with the face
plate as protection to prevent scratching the stove
top.
6
6
6
2
2
1
1
1
1
1
1
3
4
1
5
6
5
1
2
3
1
*
*
*
*
t
n
o
r
F
ST1031
install firebrick
10/08
Figure 3
Install Firebrick
Tip - Install Front (*) Fire Bricks First
ST1031
6
DW2500X02
30004581
2
5
9
6
4
3
7
2
9
9
7
8
1
ST1024
faceplate assy
10/08
Figure 5
Face Plate Assembly
ST1024



Masonry
Fireplace
End of
Spring
Spring #10
Face Plate
Assembly
ST1025
Figure 6
Install Face Plate
Chimney
CONTACT YOUR LOCAL BUILDING AUTHORITY
FOR APPROVED METHODS OF INSTALLATION.
1. A chimney connector shall not pass through an attic,
roof space, closet, floor, ceiling or similar concealed
space. Where passage through a wall or partition of
combustible constructions is desired, the installation
shall conform to CAN/CSA B365 (in Canada). In the
US, check with local building officials for require-
ments in your area.
2. It is advisable to have your masonry chimney in
-
spected for deterioration such as cracks and crum-
bling mortar before you install your unit.



6” (152 mm) Min.
Dia. Stainless
Steel Flexible
Liner
NOTES: A stain-
less steel adapter
is recommended for
fastening the stainless
steel flexible liner to
the collar.
Male or crimped end
of the adapter must
be installed inside the
flue collar. Drill flue
collar to permanently
fasten stainless steel
adapter using a mini-
mum of 3 screws.
Fasten stainless steel
chimney liner to the
stainless steel adapter
using manufactures
instructions.
ST1026
Figure 7
Chimney Liner
3. To help ensure a good draft, the top of the chimney
should be at least 3 feet (914 mm) above the point
of penetration through the roof, and be at least 2 feet
(610 mm) higher than any point of the roof within 10
feet (3 m).
4. Do not use makeshift compromises during installa-
tion.
5. Do not remove bricks or mortar from the fireplace.
Canada: This fireplace insert must be installed with
a continuous chimney liner of 6” (152 mm) minimum
diameter extending form the flue collar to the top of the
chimney. The chimney liner must conform to the class 3
requirements of CAN/ULC-S635 Standard for lining sys-
tems for existing masonry or factory-built chimneys and
vents, or CAN/ULC-S640 Standard for lining systems
for new masonry chimneys. (Fig. 7)
USA: This fireplace insert must be connected to:
1. A chimney complying with the requirements for type
HT chimneys in the Standard for Chimneys, Factory-
built, Residential type and building Heating Appli
-
ance, UL103, or
2. A code-approved masonry chimney with flue liner.
Alternate Chimney Installation
Applies to USA ONLY
Contact your local building authority for approved meth-
ods of installation.
WARNING: This fireplace insert must be connected to:
A chimney complying with the requirements for type
HT chimneys in the Standard for Chimneys, Factory-
built, Residential Type and building Heating Appliance,
7
DW2500X02
30004581
feet (3 m).
5. Do not use makeshift compromises during installa
-
tion.
6. Do not remove bricks or mortar from the fireplace.
EXCEPTION (5) Page 7:
Masonry or steel, including the damper plate, may be
removed from the smoke shelf and adjacent damper
frame if necessary to accommodate a chimney liner,
provided that their removal will not weaken the structure
of the fireplace and chimney, and will not reduce protec-
tion for combustible materials to less than required by
the National Building Code. Consult with local building
authorities having jurisdiction before starting.
IMPORTANT: Warning Label Installation
A metal warning tag has been included with your
fireplace insert. This tag is to be securely installed in
a visible location on your fireplace so that it is known
the fireplace has possibly been modified to accept the
insert.



The smoke
chamber must
be sealed using
noncombus-
tible material, to
prevent smoke
from re-enter-
ing the room.
The installation
must allow the
chimney system
to be inspected
and cleaned.
Chimney Liner
The cross-sec-
tional area must not
exceed 85 square
inches (550 cm
2
)
Chimney Con-
nector into the
first section of
the flue liner
Masonry
Fireplace
Drill flue collar to
permanently fas-
ten chimney con-
nector. A minimum
of 3 screws will be
required.
Insert
ST1027
Figure 8
Alternate Chimney Installation
Metal Tag
ST1028
Figure 9
Place Metal Tag on Masonry Fireplace
UL103 OR A code-approved masonry chimney with
chimney liner.
1. This insert must be connected to a code-approved
masonry chimney or listed factory-built fireplace
chimney. When installation is to a factory-built
fireplace chimney, a direct flue connection will be
required. Contact the chimney manufacturer or lo-
cal building authorities for approved method. When
installation is into a masonry chimney, a chimney
connector of a minimum 24 gauge steel must be in-
stalled into the first chimney liner section. The cross
sectional area of the either type of chimney must
not be less than the inside cross sectional area of
the flue collar, nor shall it be greater than 85 square
inches (550 cm
2
). The chimney connector must be
secured with a minimum 3 screws at the flue collar
and each adjoining sections.
2. A chimney connector shall not pass through an attic,
roof space, closet, floor, ceiling or similar concealed
space. Where passage through a wall or partition of
combustible construction is desired, check with local
building officials for requirements in your area.
3. It is advisable to have your masonry chimney in-
spected for deterioration such as cracks and crum-
bling mortar before you install your unit.
4. To help ensure a good draft, the top of the chimney
should be at least 3 feet (914 mm) above the point
of penetration through the roof, and be at least 2 feet
(619 m) higher than any point of the roof within 10
Blower Installation
1. Remove screws from insert body, route cord under
body and through the cut out. Attach the blower with
the screws previously removed. (Fig. 10) Blower
unit should be removed occasionally, inspected and
cleaned.
BE SURE TO DISCONNECT POWER SUPPLY BE-
FORE SERVICING BLOWER.
2. DO NOT REMOVE INSULATING MATERIAL FROM
FIRE BOX.
3. Install handle holder on left side of insert using
blower mounting screw. (Fig. 11)
8
DW2500X02
30004581
N
E
P
O
E
S
O
L
C



Face Plate
Insert
3-Prong
Grounded Plug
use 110V A, 15
Amp Supply Power
Blower Assembly
Air Control
spring Handle
Fan Mounting
Screw (2)
Handle
Holder
ST1029
Figure 10
Blower Installation



Handle
Blower Mounting
Screw
Handle Holder
ST1030
Figure 11
Install Handle Holder
Operation
Do not use a grate or elevate fire. Build wood fire
directly on hearth. When the stove is used for the first
time the solvents in the paint will smoke off.
Wood
This heater is designed to burn natural wood only. High-
er efficiency and lower emissions generally result when
burning air dried seasoned hardwood, as compared to
softwood or to green or freshly cut hardwood.
Only use dry seasoned wood. Green wood, besides
burning at only 60 percent of the fuel value of dry wood,
deposits creosote on the inside of your stove and along
the chimney. This can cause an extreme danger of
chimney fire. To be called “seasoned”, wood must be
dried for a year. Regardless of whether the wood is
green or seasoned, it should be stored in a well-shel-
tered, ventilated area to allow proper drying during the
year to come. Wood should be stored beyond recom-
mended clearance from combustibles.
DO NOT BURN:
Treated Wood Solvents Trash Coal
Garbage Cardboard Colored Paper
Instructions for First Burn - Curing the Stove Paint
Your stove has been painted with the highest quality
stove paint and has special break-in procedures. The
heat generated by the normal operation of the stove,
will serve to harden the paint.
Ventilate the house during the first three times the stove
is used. The paint on the stove will give off smoke,
carbon dioxide and an odor. Without adequate ventila-
tion, concentrations of smoke could irritate you or cause
damage to person and/or property. Open doors and
windows and use a fan if necessary. After the initial
burns the paint will be cured and there should be no
more smoke.
Each of the initial burns should be conducted as fol-
lows:
1. The first and second burns should be approximately
250° F (120° C) for approximately 20 minutes.
2. The third burn should be between 500° F (260 to
370° C) for at least 45 minutes. The important fact is
the paint should be cured slowly. Avoid hot fires dur
-
ing the curing process.
During the curing process the paint will be gummy.
Once cured the paint will remain hard.
9
DW2500X02
30004581
Inlet Air Control Settings
Desired Inlet **Approx.
Burn Setting Air Setting BTU Output
Low Fully Closed 9,500
Med / High 1/2” (13 mm) Open 16,315
High Fully Open 58,000
Never use gasoline, gasoline-type latern fuel, ker-
osene, charcoal lighter fluid or similar liquids to
start or ‘freshen up’ a fire in this heater. Keep all
such liquids well away from the heater while it is
in use.
Glass Care
The following use and safety tips should be observed.
1. Inspect the glass regularly for cracks and breaks. If
you detect a crack or break, extinguish the fire im-
mediately and contact your dealer for replacement.
2. Do not slam door or otherwise impact the glass.
When closing doors, make sure that logs or other
objects do not protrude and impact the glass.
3. Do not clean the glass with materials which may
scratch (or otherwise damage) the glass. Scratches
on the glass can develop into cracks or breaks.
4. Never attempt to clean the glass while unit is hot. If
the deposit is not very heavy, normal glass clean
-
ers are adequate with a plain, nonabrasive scouring
pad. Heavier deposits may be removed with the use
of a readily available oven cleaner.
5. Never put substances which can ignite explosively
in the unit since even small explosions in confined
areas can blow out the glass.
6. This unit has an airwash system, designed to reduce
deposits on glass.
Replace glass only with high temperature Robax
Pyroceram of the proper size and thickness.
Gasket Replacement
After extensive use, the sealing material which provides
glass and door seal may need to be replaced if it fails
to sustain its resilience. Inspect glass and door seal pe-
riodically to ensure for proper seal. If gaskets become
frayed or worn, replace immediately.
Contact your dealer for approved replacement parts.
The following steps should be followed for glass gasket
replacement:
1. Ensure appliance is not in operation and has thor
-
oughly cooled.
2. Remove screw and glass clip.
3. Lift glass out from glass clip.
4. Remove old gasket and clean glass.
5. Replace new gasket starting at the bottom of glass
working along edges, being sure to center gasket
channel on glass.
6. Trim to length and butt ends together.
7. Replace glass in door, being sure not to over-tighten
screw and clip.
It is normal to see flat spots on painted surfaces of the
stove. The flat spots on the paint surface indicate the
hotter surfaces of the stove, and is caused by the heat
radiating through the paint. It is also expected that shiny
spots caused by friction from the packaging materials,
will disappear during the curing of the stove.
SO:
1. Remember to ventilate well.
2. Allow the stove to cure before burning for long peri-
ods at high temperatures.
3. Flat spots on the painted surfaces are normal.
4. Shiny spots on the paint surface before burning is
normal.
5. Call your dealer if you have any questions.
Building a Fire
1. Open inlet air control fully.
2. Place a small amount of crumpled paper in the
stove.
3. Cover the paper with a generous amount of kindling
in a teepee fashion and a few small pieces of wood.
4. Ignite the paper and close door. If fire dies down
substantially, open door slightly.
5. Add larger pieces of wood as the fire progresses be
-
ing careful not to overload. Do not fill firebox beyond
firebrick area. An ideal coal bed of 1” to 2” should be
established to achieve optimum performance.
6. This unit is designed to function most effectively
when air is allowed to circulate to all areas of the
firebox. An ideal means of achieving this is to rake a
slight (1” to 2” wide) trough in the center of the coal
bed from front to back prior to loading the fuel.
7. Once fuel has been loaded, close the door and open
air inlet control fully until fire is well established (ap
-
prox. 10 minutes) being careful not to overfire.
8. Readjust air inlet control to desired burn rate. If
excessive smoke fills firebox, open air inlet control
slightly until flames resume and wood is sufficiently
ignited. While a basic rule of thumb is “closed-low”,
“1/2 way - medium” and “fully open-high”, refer to the
Inlet Air Control Settings chart.
9. When refueling, adjust air control to the fully open
position. When fire brightens, slowly and carefully
open the door. This procedure will prevent gases
from igniting causing smoke and flame spillage.
10.Add fuel being careful not to overload.
10
DW2500X02
30004581
The following steps should be followed for door gasket
replacement:
1. Ensure appliance is not in operation and has thor
-
oughly cooled.
2. Remove old door gasket and clean channel.
3. Using an approved high temperature gasket cement,
apply a thin coat in bottom of channel.
4. Starting at hinge side of door, work into around door
unit, and butt and trim to length.
5. Close door and allow three to four hours for cement
to set before restarting appliance.
Creosote
When wood is burned slowly, it produces tar and other
organic vapors. These combine with moisture to form
creosote. Creosote vapors condense in the relatively
cool chimney flue of a slow-burning fire. As a result,
creosote residue accumulates on the flue lining. When
ignited, this creosote makes an extremely hot fire.
The chimney should be inspected regularly during the
heating season to determine if a creosote build-up has
accumulated. If this is the case, the creosote should be
removed to reduce the risk of chimney fire.
Ways to Prevent and Keep Unit Free of Creo-
sote
1. Burn with air control open for several minutes at
numerous intervals throughout the day during the
heating season, being careful not to over-fire unit.
This removes the slight film of creosote accumulated
during low burn periods.
2. Burn stove with draft control wide open for several
minutes every time you apply fresh wood. This al-
lows wood to achieve the charcoal stage faster and
burns wood vapors which might otherwise be depos-
ited within the system.
3. Burn only seasoned wood. Avoid burning wet or
green wood. Seasoned wood has been dried for at
least one year.
4. A small hot fire is preferable to a large smouldering
one that can deposit creosote within the system.
5. Establish a routine for the fuel, wood burner and
firing technique. Check daily for creosote build-up
until experience shows how often you need to clean
to be safe. Be aware that the hotter the fire, the less
creosote is deposited. Weekly cleaning may be nec-
essary in mild weather even though monthly clean-
ing may be enough in the coldest months. Contact
your local municipal authority for information on how
to handle a chimney fire. Have a clearly understood
plan to handle a chimney fire.
WARNING: Things to remember in case of chim-
ney fire: 1. Close draft control. 2. Call the fire de-
partment.
Ash Disposal
During constant use, ashes should be removed every
few days, or whenever ashes get to three to four inches
deep in the firebox. Remove ashes only when the fire
has died down and the ashes have cooled. Even then,
expect to find a few hot embers.
Ashes should be placed in a metal container with a
tight-fitting lid. The closed container of ashes should
be placed on a noncombustible floor, well away from
all combustible materials, pending final disposal. If
the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled. Other
waste should not be placed in the ash can.
Inspection of the Insert
Inspection of the insert can be accomplished with the
removal of the face plate only. Once the face plate
has been removed, there should be enough space to
inspect the insert with the aid of a flash light. To remove
face plate, follow face plate installation instructions on
Page 7.
IMPORTANT
Helpful Hints
1. What is the correct way to start a fire?
a. You will need small pieces of dry wood (kindling)
and paper. Use only newspaper or paper that has
not been coated or had unknown materials glued
or applied to it. Never use coated (typically adver-
tising flyers) or colored paper.
b. Open the door of the wood stove.
c. Crumple several pieces of paper and place them
in the center of the firebox and directly on to the
firebricks of the wood stove. Never use a grate to
elevate the fire.
d. Place small pieces of dry wood kindling) over the
paper in a teepee manner. This allows for good
air circulation, which is critical for good combus-
tion.
e. Light the crumpled paper in 2 or 3 locations:
NOTE: It is important to heat the air in the stove-
pipe for draft to start.
f. Fully open the air control of the wood stove and
close the door until it is slightly open, allowing
for much needed air to be introduced into the fire
box. Never leave the door fully open as sparks
from the kindling may occur causing injury or
property damage. As the fire begins to burn the
11
DW2500X02
30004581
kindling, some additional kindling may be needed
to sustain the fire. DO NOT add more paper after
the fire has started.
g. Once the kindling has started to burn, add some
of the smaller pieces of seasoned (dry) firewood.
NOTE: Adding large pieces at the early stages
will only serve to smother the fire. Continue
adding small pieces of seasoned (dry) firewood,
keeping the door slightly open until each piece
starts to ignite. Remember to always open the
door slowly when placing wood into the fire.
h. Once the wood has started to ignite and the
smoke has reduced, close the wood stove door
fully. The reduction of smoke is a good indication
that the draft in the chimney has started and good
combustion is now possible. Larger pieces of
seasoned (dry) firewood can now be added when
there is sufficient space in the firebox. Adjust the
air control setting to desired setting.
i. NOTE: The lower the air control setting the longer
the burn time of your firewood.
2. What type of wood is best to use as firewood?
Dry seasoned hardwood should be used. Avoid
green unseasoned wood. Green wood, besides
burning at only 60 percent of the fuel value of dry
seasoned wood, will deposit creosote on the inside
of your stove and along the inside of your chimney.
3. What does dry seasoned wood mean, and what
is considered hardwood?
Wood that has been dried for a period of one year
in a well-ventilated and sheltered area would be
considered dry seasoned wood. Hardwoods are
generally from slow growth trees (Example: Oak and
fir) Softwoods are generally from fast growth trees.
(Example: Pine and spruce).
4. Will following the above listed steps for starting
a fire result in perfect results all the time?
The quick answer is most of the time. There are
many variables that may affect your success rate
when starting a fire. Most of those variables and how
to deal with them will be learned through experience.
Your ability to start a good fire will significantly in-
crease with time and patience. Some of the reasons
for poor stove performance will be covered next.
5. Why can’t I get the fire lit?
Damp or wet wood and poor draft are the main rea-
sons for poor results in starting a fire. Always use dry
seasoned wood for your fire. Even wood dried for
two years will be difficult to ignite, if it has become
wet.
6. Why is there always a large quantity of thick
black smoke present in the firebox?
A large quantity of thick black smoke in the firebox,
is a good indication that the draft is poor.
7. Is it normal for soot to cover the glass at the
beginning of a fire?
Your stove has been built with an air wash system
that will help keep the glass clear when the firebox
has reached a good operating temperature and has
a good draft. Cold firebox temperature and poor draft
cause sooting of the glass. Once the firebox temper-
ature and the draft increases, the soot will burn off.
8. What is draft?
Draft is the ability of the chimney to exhaust draw
by-products produced during the normal combustion
process.
9. What can cause a poor draft?
The most common factors for poor draft are:
a. Atmospheric pressure and air supply
b. Environmental conditions
c. Cold chimney temperature
d. Poor chimney installation and maintenance
a. Atmospheric Pressure and Air Supply
Atmospheric pressure affecting the draft from a
chimney can be either outside the home, inside
the home or both. Outside the home, a high-pres-
sure day (clear and cool) generally creates a bet-
ter draft in the chimney than a low-pressure day
(overcast and damp). Inside the home, normal
household appliances, such as clothes dryers
and forced air furnaces compete for air resulting
in inadequate amounts of air available to fuel a
fire and create a condition known as negative
pressure. Under extreme conditions of nega-
tive pressure the combustion by-products can
be drawn from the chimney and into the house.
12
DW2500X02
30004581
This condition is commonly referred to as down
drafting. There are several factors that impact the
amount of air available in the home. Increased
amounts of insulation vinyl windows, extra caulk-
ing in various places and door seals can all keep
heat in but may also make a home too airtight.
If you are in doubt about whether or not there is
sufficient air in your home for your stove, curtail
using those appliances known to consume the
air where possible, or open a window or door to
allow air to enter the home.
b. Environmental Conditions
High trees, low lying house location such as in
a valley, tall buildings or structures surrounding
your house and windy conditions can cause poor
draft or down drafting.
c. Cold Chimney Temperature
Avoid cold chimney temperatures by burning a
hot fire for the first fifteen to forty minutes, being
careful not to over fire. If any part of the chimney
or parts of the stove start to glow, you are over fir-
ing the stove. Where possible, install a tempera-
ture gauge on the chimney so temperature drops
can be seen.
d. Chimney Installation and Maintenance
Avoid using too many elbows or long horizontal
runs. If in doubt, contact a chimney expert and/or
chimney manufacturer for help. Clean chimney,
rain caps and especially spark arrester regularly,
to prevent creosote build up, which will signifi-
cantly reduce chimney draw and may cause a
chimney fire.
10.Should I close or open the air control fully when
shutting down the stove?
When shutting down the stove, fully open the air
control. This allows the chimney temperatures to
remain as high as possible for as long as possible.
Cold chimney temperatures create creosote.
NOTE: this sheet is intended as an aid and does not
supersede any local, provincial or state requirements.
Check with officials or authorities having jurisdiction in
your area.
13
DW2500X02
30004581
23
23
23
19
19
18
18
18
18
18
18
20
21
18
22
23
22
18
3
12
4
5
10
8
7
1
2
6
14
13
9
11
16
17
15
25
28
32
29
27
26
30
25
31
30
33
24
31
4581
DW2500x2 parts
10/08
34
34
35
MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without
notice.
DW2500X02 Wood Insert
Item No. Description Qty. Part No.
1. Door Casting - Black 1 S12070
2. Glass and Gasket 1 S31340
3. 1/8” (3 mm) Glass Gasket 4.6’ S15001
4. 5/8” (16 mm) Door Gasket 5.2’ S15011
5. Pawl Assembly 1 30002362
6. Handle - Black, Wood 1 1600664
7. Insert Lifter Handle - Nickel 1 1600650
8. Screw - 1/4-20 x 3 1 1201310
9. Handle Assembly 1 5004245
10. Lock Nut 1 1203290
11. Glass Clips 4 S37034
12. Screw #10 x 1/2 4 S11086
13. Hinge Pin 2 S11005
14. 3/8 Retaining Ring 2 S11090
14
DW2500X02
30004581
DW2500X02 Wood Insert (continued)
Item No. Description Qty. Part No.
15. Baffle Assembly 1 S41467
16. Secondary Air Tube 3 S32711
17. Cotter Pin 3 S11421
18. Firebrick 4⁷⁄₁₆” (113 mm) x 9” (229 mm) x 1¹⁄₄” (32 mm) 9 S16040
19. Firebrick 4⁷⁄₁₆” (113 mm) x 7¹⁄₄” 184 mm) x 1¹⁄₄” (32 mm) 2 S16043
20. Firebrick 4
⁷⁄₁₆” (113 mm) x 4¹⁄₂” (114 mm) x 1¹⁄₄” (32 mm) 1 S16046
21. Firebrick 2
¹⁄₄” (57 mm) x 8” (203 mm) x 1¹⁄₄” (32 mm) 1 S16271
22. Firebrick - Angled 2 S16013
23. Firebrick 4
⁷⁄₁₆” (113 mm) x 8” (203 mm) x 1¹⁄₄” (32 mm) 4 S16138
24. Faceplate - Top 1 S38050
25. Faceplate - Side 2 S38051
26. Trim - Top Right 1 90000072
27. Trim - Top Left 1 90000071
28. Trim - Side Right 1 90000076
29. Trim - Side Left 1 90000075
30. Corner - 90° 2 S11092
31. #8 Screw 6 50960
32. Spring 2 S11403
33. Articulated Angle 1 S11127
34. Back plate, Trim Corner 2 30004606
35. Back plate, Articulated Angle 2 30004607
15
DW2500X02
30004581
Limited Lifetime Warranty
Limited Three Year Warranty
MHSC (hereafter referred to as the “company”) warrants that
your new Dutchwest brand wood burning plate steel stove or
masonry wood insert is free from manufacturing and material de
-
fects for a period of three years from the date of sale, subject to
the following conditions and limitations.
Limited One Year Warranty
Electrical components such as blowers and speed controls are
covered for one year only. Glass door panels are covered for
thermal breakage only. To clean glass, use a ceramic glass
cleaner or polish. Do not use ammonia-based cleaners. A suit
-
able cleaner is available from your nearest Hearth Products deal-
er. DO NOT CLEAN GLASS WHILE HOT AND DO NOT USE
ABRASIVE CLEANERS.
Excluded from Warranty
Brass parts should be cleaned with soap and warm water and
immediately dried. Brass parts may also be damaged by external
chemicals. Gold and any other plated parts will not be covered
under this warranty. Plated surfaces should be cleaned by using
denatured alcohol only and rubbed lightly with a lint-free non-
abrasive cloth. Excessive rubbing or polishing may remove the
plated finish. Discoloration of certain parts is normal and is not a
defect, and therefore not covered under warranty.
This warranty will not include or extend to paint, gaskets, baf-
fles or firebrick components, and does not cover any removable
firebox components such as brick retainers or stainless steel air
tubes.
Extended Limited Lifetime Warranty
The company offers a limited lifetime warranty on the firebox
(welds only), castings and ash drawers on any of Dutchwest
wood burning products. The limited lifetime warranty is extended
to the original owner only, and is subject to proof of purchase by
the original owner and residential use.
1. The new Dutchwest product must be installed and operated at all
times in accordance with the installation and operation instruc-
tions supplied with the appliance, and installation must be to local
and national codes. Any alterations, willful abuse, accident, over
firing or misuse will not be covered under warranty. NOTE: Some
minor movement of certain parts is normal and is not a defect
and therefore, not covered under warranty.
2. The warranty is non-transferable, and is made to the original
owner, provided that the purchase was made through an autho
-
rized MHSC supplier. The serial number must be supplied along
with the Bill of Sale, showing the date of purchase, at the time the
claim is submitted.
3. This warranty is limited to the repair or replacement of parts
only and is applicable only to those parts found to be defective
in material or construction that have been subjected to normal
conditions of use and service. All defects must be confirmed by
the company or an authorized representative. If requested by the
company, defective parts must be shipped back transportation
prepaid, to the company. Credits will be issued upon receipt of
return of the defective product to the company.
4. The company, at its discretion, can fully discharge all obligation
with respect to this warranty by refunding the wholesale price of
the defective part(s).
5. Any installation, labor, construction, transportation or other re
-
lated costs or expenses arising from defective parts, repair,
replacement or otherwise of same, will not be covered by this
warranty, nor will the company assume responsibility for same.
Further, the company will not be responsible for any incidental,
indirect or consequent damages, except as provided by law, and
in no event shall they exceed the original purchase price.
6. All other warranties - expressed or implied - with respect to the
product, its components and accessories, or any obligations /li-
abilities on the part of the company are hereby expressly ex-
cluded.
7. MHSC neither assumes, nor authorizes any third party to as-
sume, on MHSC’s behalf, any other liabilities with respect to the
sale of this MHSC product.
8. The warranties as outlined within this document do not apply to
chimney components or other products made by other manufac-
turers when used in conjunction with the installation of this prod-
uct. Improper use or the use of non-approved components may
nullify your warranty. If in doubt, contact your nearest authorized
MHSC supplier or MHSC Customer Service Department.
9. MHSC will not be responsible for:
Down drafts or spillage caused by environmental conditions
such as near-by trees, buildings, rooftops, hills, mountains or
ineffective chimney design.
Inadequate ventilation, excessive offsets or negative air
pressure caused by mechanical systems such as furnaces,
clothes dryers, fans, etc.
10. This warranty is void if:
The appliance has been operated in atmospheres contami-
nated by chlorine, fluorine, or other damaging chemicals.
This appliance has been subjected to prolonged periods of
dampness or condensation.
The appliance has any damage due to water, or weather
damage that is the result of, but not limited to, improper chim-
ney/venting installation.
The appliance has been subjected to willful or accidental
abuse or misuse.
Corrosive driftwood, manufactured logs or other fuels are
used other than as outlined in the installation and operating
instructions.
The appliance is not maintained in good condition, including
firebrick and gaskets.
IF WARRANTY SERVICE IS REQUIRED
Contact MHSC Customer Service. Make sure you have your
sales receipt and the model/serial number of your MHSC prod-
uct.
Do not attempt to do any service work yourself, unless pre-ap
-
proved by MHSC in writing this will void the warranty.
MHSC must authorize service and provide a Warranty Claim
Number prior to any warranty related service calls. Without an
authorization number, any service work will not be deemed war-
ranty.
NOTE: Some states and provinces do not allow the exclusion
or limitation of incidental or consequential damages. The above
limitation may not apply to you.
MHSC
149 Cleveland Drive
Paris, KY 40361
KEEP THIS WARRANTY
Serial # _______________________________
Model # ______________________________
Date Purchased ________________________
16
DW2500X02
30004581
NOTA : Gardez cette feuille pour consultation futur
Cet appareil est fabriqué our le raccordement à une chemi-
née par connexion de diam. 152 mm (6 po) (voir page 23)
Approuvé par l’EPA comme poêle
inséré à grande efficacité
Modèle W2500X02
DUTCHWEST
4581
DW2500X02 cover
10/08
Note concernant la sécurité
Lire le manuel en entier avant d’installer et d’utiliser votre poêle inséré.
Si le poêle n’est pas installé correctement, votre maison pourrait passer au feu.
Pour réduire les risques d’incendie, observez les instructions d’installation.
Autrement, vous pourriez provoquer des dommages matériels, des blessures corporelles, voire mortelles.
Communiquer avec les représentants responnsables des permis, des restrictions et de l’inspection des installations
dans votre région.
Cet appareil n’est pas approuvé pour les maison mobiles.
Nous recommandons que nos appareils de
chauffage au bois soient installés et entretenus
par des professionnels qui ont été accrédités aux
É.-U. par le National Fireplace Institute® (NFI)
comme étant des spécialistes du NFI en matière
d’appareils de chauffage au bois, ou qui sont ac
-
crédités au Canada dans le
cadre du Programme de for-
mation technique en énergie
du bois (WETT).
Guide du propriétaire
Pour installation résidentielle
17
DW2500X02
30004581
Mise En Garde
Aprés avoir lu ces instructions, si vous avez des doutes
quant à votre capacité de faire toute l’installation d’une
manière professionnelle, vous devriez retenir les servic-
es d’un installateur qui s’y connaît relativement à tous
les aspects d’une installation à la fois sûre et correcte.
NE FAITES PAS de compromis temporaires lorsque
vous faites l’installation.
Avant d’installer votre appareil
1. Chaud pedant son utilisation. Tenir loin des en-
fants, des vêtements et du mobilier. Tout contact
avec la peau pourrait provoquer des brûlures.
2. Ne pas brûler des déchets ne de liquides inflam-
mables dans ce poêle.
3. Assurez-vous avec le bureau de l’inspecteur des
bâtiments que votre installation respecte les codes
locaux; vous pourriez avoir besoin d’un permis pour
installer votre poêle.
4. Cet appareil ne peut être inséré que dans un foyer
en maçonnerie. N’installez pas cet appareil dans
un foyer fabriqué en usine, comme un foyer sans
espace libre.
5. Raccordez toujours cet appareil à une cheminée
et ne permittez JAMAIS que les émanations soliet
dirigées vers une autre pièce ou à l’intérieur de
l’immeuble.
6. Ne raccordez pas cet appareil sur un réseau ou
un systeème de répartition de l’air.
7. NE RACCORDEZ PAS cet appareil sur une chemi-
née déjà raccordée sur un autre appareil.
8. Une doublure interne de cheminée en acier inoxyd
-
able peut être nécessaire. Consulter l’autorité régle-
mentaire locale (inspectin des bâtiments, prévention
des incendies, etc.)
9. N’utilisez pas de produit chimique ni de liquide
pour allumer le feu.
10.Le tuyau de raccordement et la cheminée doivent
être inspectés périodiquement et nettoyés lorsque
c’est nécessaire.
11. Rappelez-vous les espaces de dégagement requis
lorsque vous placez des meubles ou d’autres objets
dans la pièce. N’ENTREPOSEZ PAS de bois, de
liquides inflammables ni d’autres matières combus-
tibles trop près de votre appareil.
12.Communiquez avec vos autorités municipales ou
provinciales en matière d’incendie pour avoir des
infomations sur ce qu’il faut faire en cas d’incendie
de cheminée. Ayez un plan bien arrêté sur ce que
vous devez faire en cas d’incendie de cheminée.
En cas d’incendie de cheminée, fermez le contrôle
d’admission d’air et TÉLÉPHONEZ AU SERVICE
DES INCENDIES.
13.NE TRAFIQUEZ PAS
la commande d’admission
d’air au-delà de son réglage normal.
Fonctionnement
L’importance d’une taille correcte pour la cheminée
Le fonctionnement optimal de l’appareil est obtenu avec
une cheminée de diamètre 152 mm (6 po) ou plus. Le
diamètre de la cheminée ne doit pas dépasser 254
mm (10 po); la section de la cheminée ne doit pas être
supérieure à 550 cm
2
(85 po
2
).
Les appareils à combustible solide utilisés aujourd’hui
sont beaucoup plus efficaces que les équipements du
passé. De par sa conception, votre appareil produit
une combustion contrôlée avec un bon transfert de
chaleur, en minimisant la consommation de combus-
tible. L’amélioration du transfert de chaleur réduit la
température dans la cheminée, et il est alors important
que la taille de la cheminée soit adéquate pour qu’elle
produise un bon tirage. Un tirage déficient dégrade la
performance de l’appareil et suscite un risque pour la
sécurité.
Advenant que la combustion soit médiocre ou que de
la fumée se répande dans a pièce, consulter un expert
local en cheminées.
Taux de combustion
Fermez la porte de votre appareil. Le taux de combus-
tion est réglé par la quantité d’air que vous laissez
entrer dans votre apareil par la commande d’admission
d’air. À mesure que vous vous familiariserez avec ce
genre de chauffage, vous apprendrez à régler la com-
mande d’air en fonction de la quantité de chaleur ou de
la durée de la combustion.
Se vous essayez d’obtenir des taux de chauffage plus
élevés, des taux qui dépassant la fiche technique de
l’appareil, vous risquez de provoquer des dommages
permanents à votre appareil. La quantité de bois
recommandée est le dessus de la brique réfractaire.
Toute surcharge de votre appareil pourrait limiter la
quantité d’air entrant dans votre appareil pour obtenir
une bonne combustion.
Il ne faut pas trafiquer a commande d’admission d’air
de combustion au-delà de sa capacité normale.
Avertissementé N’utilisez cet appareil de chauffage que
lorsque sa porte est fermée.
14.Une fois que le tirage requis est étabil, n’utilisez
votre appareil qu’en tenant les portes fermées; ovrez
les portes lentement lorsque vous remettez du bois
dans le foyer. (En procédant ainsi, vous réduirez ou
éliminerez même tout déversement de fumée dans
la pièce). Ces appareils ne sont pas conçus pour
être utilisés dans les mainsons mobiles. N’installez
pas cet appareil dans une maison mobile ou dans
une remorque.
18
DW2500X02
30004581
TOUJOURS FOURNIR UNE SOURCE D’AIR FRAIS
DANS LA PIÈCE L’UNITÉ EST INSTALLÉE.
L’ÉCHEC POUR FAIRE SI PEUT AVOIR POUR
RÉSULTAT DE LA FAMINE D’AIR D’AUTRE CAR-
BURANT BRÛLE DES APPAREILS ET LE DÉVEL-
OPPEMENT POSSIBLE DE CONDITIONS HASAR-
DEUSES.
L’APPAREIL DEVIENT TRÈS CHAUD EN UTILI-
SATION. DE GRAVES BRÛLURES PEUVENT
ÊTRE CAUSÉES À SON CONTACT. IL FAUT ÊTRE
PARTICULIÉREMENT PRUDENT EN PRÉSENCE
D’ENFANTS.
Caractéristiques
Modéle DW2500X02 non-catalytique. Ce poêle respecte les limits d’emission pour les poêles à bois fixées par
l’agence Américaine de protection de l’environnement. Dans des conditions spécifiques, ce poêle dégage entre 9 500
à 58 000 BTU à l’heure.
Modéle DW2500X02 a été enregistré OMNI-Test Laboratories à Portland, OR, comme respectant ou dépassant les
norme ULC S 627-00 Canada et UL 1482 US.
1118 mm (44 po)
787 mm
(31 po)
235 mm
(9 po)
527 mm (20 po)
*
413 mm
(16 po)
254 mm
(10 po)
406 mm
(16 po)
679 mm (26 po)
225 mm
(8 po)
553 mm
(21 po)
4581
DW2500X02 dims Fr
11/08
* Réglable 254 mm (10 po) à 356 mm (14 po)
Nota : referez à la pages 21 et 22 pour la dé-
gagements et le protecteur de plancher
Figure 1
Dimensions du poêle
Avertissement relatif à la proposition 65 : Les combustibles
utilisés dans les appareils de chauffage au gaz, au bois ou
au mazout, ainsi que les produits de combustion de ces com-
bustibles, contiennent des produits chimiques que l’État de la
Californie considère comme cancérogènes et responsables
d’anomalies congénitales et d’autres pathologies du système
reproductif.
California Health & Safety Code Sec. 25249.6
19
DW2500X02
30004581
Installation
1. Retirez de l’appareil toute boîte de briques et autres
paquets.
2. Nettoyez le foyer en maçonnerie et assurez-vous
que les cendres sont placées dans un contenant en
métal.
3. Retirez ou verrouillez la plaque de régulation de
tirage du foyer en maçonnerie en position ouverte.
4. Consultez l’autorité réglementaire locale (inspec
-
tion des bâtiments, prévention des incendies, etc.)
au sujet des permis à obtenir et des exigences
d’inspection de l’installation, et au sujet des restric-
tions applicables.
5. Lors de l’installation de l’appareil, veiller à respecter
les distances de dégagement prescrites mention-
nées sur l’étiquette d’homologation de l’appareil (à
l’arrière de l’appareil) et ci-dessous, pour la sépara-
tion des matériaux combustibles et la protection du
plancher. Voir à la page 5 d’autres instructions au
sujet de la protection des planchers.
Si vous ne laissez pas les espaces libres mini-
mum requis, l’installation pourrait présenter des
dangers au niveau de la sécurité.
6. Installez la brique réfractaire. (Fig. 3)
7. Installez la devanture sur le poêle inséré. (Page 23)
La garniture devrait être en contact avec l’avant du
foyer. Si l’ajustement n’est pas parfait, utilisez une
bande d’isolation en fibre de verre de 51 mm (2 po)
de largeur pour obtenir un bon ajustement.
A
B
C
D
E
F
ST1022
DW2500 clearances
10/08
Manteau de cheminée
Garniture supériure
Placque avant
Plancher
Mur latéral
Garniture latéral
305 mm
(12 po)
Max
ST1022
Espace libre par rapport aux matières combustibles
A Appareil et mur latéral 305 mm (12 po)
B Appareil et garniture supérieure 254 mm (10 po)
C Appareil et garniture latérale 254 mm (10 po)
D Appareil et manteau de cheminée 430 mm (17 po)
E Protection du plancher (avant) 405 mm (16 po) aux É-U
457 mm (18 po) en Canada
F Protection du plancher (côtés) 203 mm (8 po)
Voir les exigences de protection des planchers à la
page suivante
Figure 2
Espace libre
20
DW2500X02
30004581
6
6
6
2
2
1
1
1
1
1
1
3
4
1
5
6
5
1
2
3
1
*
*
*
*
t
n
o
r
F
ST1031
install firebrick
10/08
Figure 3
Installation de la brique réfractaire
Avis - Installer les briques (*) du devant en premier
Devant
ST1031
Protecteur de plancher
Cet appareil doit être installé
dans une enceinte de foyer en
maçonnerie construite conformé-
ment aux normes de sécurité de
la construction locales. Ne pas
installer dans un foyer de fabrica-
tion industrielle comme un foyer
intégre.
Le protecteur de plancher doit
être étendu de façon à couvrir la
surface illustrée dans le schéma
ci-dessous.
Lorsque le plancher recouvrant la
surface illustrée dans le schéma
est en béton, aucun protecteur de plancher n’est néces-
saire.
Le protecteur de plancher ne doit pas être recouvert par
du tapis ni aucune autre matière combustible.
Si une surface combustible recouvre le plancher de
béton, un espace de la grandeur de la surface réservée
au protecteur de plancher doit être dégagé. Voir le
schéma ci-dessous. (Fig. 4)
Si la surface illustrée dans le schéma ci-dessous est un
plancher combustible ou est recouverte d’une matière
combustible, un carton à l’enrouleuse non-combustible
de 10 mm (3/8 po) ou un équivalent durable doit être
installée pour protéger le plancher. La plaque de carton
doit recouvrir la surface illustrée.
Un plancher en tuiles de céramique cimenté installé en
conformité avec les normes de sécurité de la construc-
tion locales est considéré comme étant un équivalent
durable.



8” (203 mm)
16” (406 mm) in the US
18” (457 mm) in Canada
8” (203 mm)
Plaque
avant
Protecteur de plancher
Face de l’appareil
où se trouve la
porte
ST1023
Figure 4
Protecteur de plancher
Assemblage de la devanture
Referez à Figure 5
1. Assemblez le dessus (article 1) et les côtés (article
2) à l’aide de vis Tek (article 10) #8 de 13 mm (1/2
po).
2. Installez les garnitures latérales gauche est droite
(articles 5 et 6) sur les côtés (article 2) à l’aide des
vis #8 en laiton.
3. Installez les garnitures supérieures gauches et
droite (articles 3 et 4) ensemble avec les cornières
d’articulation (article 8).
4. Installez les supports de coin (article 7) sur la garni
-
ture supérieure.
5. Installez la garniture supérieure sur la devanture et
placez les supports de coin dans la garniture laté-
rale; serrez les vis dans les supports de coin pour
fixer le reste de l’assemblage.
Installation de la devanture
1. Accrocher un bout du ressort dans le trou sur ahut
du poêle. (Fig. 6)
2. Accrochez l’autre extrémité du ressort dans l’orifice
de 3 mm ( 1/8 po) du dessus de la devanture.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

DutchWest DW2500X02 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

dans d''autres langues