Ossian LS Assembly And Operation Manual

Taper
Assembly And Operation Manual
ENGLISH ESPAÑOL FRANÇAIS
ASSEMBLY AND OPERATION
MANUAL
OSSIAN LS® is a trademark of Ossian Inc. • Patents Pending • OSSIAN LS® ASSEMBLY AND OPERATION MANUAL © 2009 OSSIAN INC.
OSSIAN INC. Davenport, Iowa • PH: 800-553-8011 • [email protected] • www.ossian.com
MANUAL 2029-07
ENGLISHESPAÑOL
FRANÇAIS
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 1
CUSTOMER SERVICE AND TECHNICAL SUPPORT
CONTACT OSSIAN INC. 1-800-553-8011
To aid in all customer service, technical support and warranty inquiries, you may be asked for the serial number and/or pump model of your Ossian LS®.
To locate both numbers open the orange cover revealing the pump compartment. The serial number is located in the pump compartment of the unit in front
of the pump. The pump model number can be found on the pump label. Record these numbers in your manual for easy accessibility.
00000000000
SERIAL # ________________________________________________
PUMP # _________________________________________________
PURCHASE DATE ______________________________________
VENDOR _______________________________________________
ENGLISHESPAÑOL
FRANÇAIS
2 | OSSIAN
Before starting, read and understand operator
manual for safe operation and maintenance.
Failure to do so may result in serious injury or
damage to machine.
Risk of re or explosion.
DO NOT spray ammable or combustible or other
unauthorized liquid. DO NOT spray any liquid not
authorized by Ossian. For a list of approved products:
800-553-8011 or visit the website: www.OSSIAN.com
Risk of electrocution.
NEVER spray near power source.
Risk of eye injury.
Spray can propel objects. Always wear safety goggles.
Risk of fall. Risk of serious injury.
Use of sprayer can create puddles and slippery
surfaces.
Risk of serious back injury.
DO NOT lift unit with full tank installed.
Risk of serious injury.
NEVER spray people or animals.
DO NOT direct spray at an open ame. Spray
equipment is not a re extinguishing device.
SAFETY
DO NOT apply anti-icing chemicals below 15˚ F.
Use dry ice melting chemicals at lower temperatures.
DO NOT spray water when freezing temperatures are
expected. Frozen plumbing and pump damage will occur.
DO NOT store water in unit when freezing temperatures
are expected. Frozen plumbing and pump damage will
occur.
ONLY use Ossian approved liquids in sprayer.
Warranty will be voided if used with unapproved product.
DO NOT modify sprayer in any way.
Warranty is voided with any modication.
NEVER operate unit with broken or missing parts, or
without protective housing or covers.
This equipment is designed to be used with Ossian
authorized parts ONLY. If equipment is used with parts
that DO NOT comply with minimum specications, user
assumes all risks and liabilities.
ADDITIONAL INSTRUCTIONS AND CAUTIONS FOUND
THROUGHOUT ASSEMBLY AND OPERATION MANUAL
DANGER
WARNING
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 3
CONTENTS
SAFETY ...........................................................................................................
PARTS AND ACCESSORIES ..........................................................................
UNPACKING AND ASSEMBLY .......................................................................
HOSE STORAGE BRACKET AND WAND HOLSTER ASSEMBLY ......
SPRAY WAND AND HOSE ASSEMBLY .................................................
BATTERY INSTALLATION ...............................................................................
BATTERY CHARGING .....................................................................................
PROPER BATTERY CARE ..............................................................................
ANTI-ICER TANK PREPARATION ...................................................................
BASIC OPERATION
POWER UP / POWER DOWN ................................................................
SPRAY BOOM APPLICATION ................................................................
ANTI-ICING SIDEWALKS .......................................................................
ANTI-ICING STAIRS................................................................................
BASIC CAUTIONS: SIDEWALK AND STAIRS ......................................
DE-ICING .................................................................................................
TROUBLE SHOOTING:
Please consult our website: www.OSSIAN.COM
or contact us at 800-553-8011
PAGE
2
4
5
6
7
8
9
10
11
12
13
14
15
16
17
ENGLISHESPAÑOL
FRANÇAIS
4 | OSSIAN
PARTS AND ACCESSORIES
Make sure ALL PARTS shown below are present in box.
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 5
UNPACKING AND ASSEMBLY
The Ossian LS® is shipped with the operator handle attached to base
unit by the control cable and power harness, but not bolted to base unit.
2) Slide handle ends into handle brackets on base.
Slip holes in handle ends over stud in handle bracket.
3) Secure handle to bracket with washers (D1) and nuts (D2).
1) CAREFULLY lift handle up from box sleeve.
DO NOT stress or kink connecting cables.
ENGLISHESPAÑOL
FRANÇAIS
6 | OSSIAN
UNPACKING AND ASSEMBLY
HOSE STORAGE BRACKET AND WAND HOLSTER ASSEMBLY
1) Assemble hose storage brackets to left and right sides of
operator handle. Insert hose brackets (A1) through holes
on outside of operator handle. Secure with (A2) washers
and (A3) acorn nuts.
2) Mount wand holster to handle on operator’s right.
Insert bolt/washer (F5) through slot in handle bracket
and secure with washer (F3) and acorn nut (F4).
Insert bolt (F2) through holster mounting bracket and
operator handle and secure with washer (F3) and nut (F4).
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 7
UNPACKING AND ASSEMBLY
SPRAY WAND AND HOSE ASSEMBLY
1) To remove stem plug, push restraining collar squarely
against bulkhead tting. Hold collar against tting when
pulling on plug to remove.
2) Insert hose stem into bulkhead tting. Pull gently to assure
that hose stem is rmly seated.
3) Secure wand hose to operator handle with tie wrap (E).
4) Screw threaded end of wand lance (B3) to wand trigger (B2).
5) Carefully screw nozzle assembly (B4) to wand lance.
DO NOT over tighten nozzle assembly to wand lance.
6) Carefully screw the threaded end of the wand hose to the
wand trigger.
ENGLISHESPAÑOL
FRANÇAIS
8 | OSSIAN
1) Lift orange cover from rear catch and pivot forward
providing access to battery cover and battery compartment.
2) With a Phillips screwdriver unscrew battery cover and rotate
out of position to expose battery compartment.
3) Inside battery compartment nd battery leads and extend
above opening to compartment.
4) Connect battery leads from battery compartment to
corresponding terminals on battery.
Connect Black Lead to Black Terminal.
Connect Red Lead to Red Terminal.
5) Install battery into compartment using care not to pinch
wiring harness and screw battery cover shut.
BATTERY INSTALLATION
Battery is shipped uninstalled from unit.
Battery can be found boxed, inside tank cavity of the OSSIAN LS®.
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 9
BATTERY CHARGING
Fully Charge Battery Prior to First Use.
1) Locate charging port on operator’s left side of rear battery
compartment tower. Remove liquid tank and raise orange
cover to aid in accessing port.
2) Plug round end of battery charger into charging port on
battery tower.
3) Plug battery charger transformer into standard 110w outlet.
4) LED will turn red when battery is below a full charge.
5) LED on transformer will turn green when battery is fully charged.
6) When battery is fully charged, disconnect battery charger from
charge port and close cover. Push rear of cover down so that it
ts snuggly over battery cover.
Only use provided battery charger.
ENGLISHESPAÑOL
FRANÇAIS
10 | OSSIAN
PROPER BATTERY CARE
Although the Ossian LS® is designed for winter operation, proper battery care is required to ensure the unit
will continue to operate at peak performance. Failure to do so will dramatically shorten the life of your battery.
Recharge battery at end
of each use for optimum
performance.
Reinstall terminal covers on battery
if disconnected for any reason.
DO NOT FREEZE BATTERY
NEVER attempt to fully drain battery.
DO NOT store in unheated area with less
than 50% charge on battery. Battery damage
can occur.
Battery must be properly installed in unit
to charge.
DO NOT turn on unit or attempt to operate
unit while charging.
Keep battery cable clear of being pinched
under battery when installing.
Check battery cover is rmly secured with
both screws. Battery cover will be used to lift
unit.
WARNING
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 11
ANTI-ICER TANK PREPARATION
The Ossian LS® Liquid Sprayer uses a standard Ossian 5 gallon tank as its liquid tank.
An empty tank was provided with the unit. To begin operation, a full tank is required.
1) Attach supplied siphon cap to full tank of Ossian approved
liquid anti-icer. Hand tighten.
2) Install full anti-icer tank into tank cavity of sprayer with
cover of unit closed.
Use proper lifting technique when lifting full liquid tank.
A full tank can weigh up to 60lbs.
3) Plug female connection on siphon hose into male inlet port in
back of tank compartment. Apply gentle back and forth twisting
motion.
4) When removing tank, unplug female connection on siphon hose
from base unit prior to lifting tank.
DO NOT attempt to open cover to remove tank.
Use of unapproved chemicals
will void equipment warranty.
ENGLISHESPAÑOL
FRANÇAIS
12 | OSSIAN
1) To energize unit, rotate knob on user control pod,
clockwise from to
If plumbing is not primed, pump will run for 10-15
seconds to prime internal plumbing and wand
hose with de-icer before shutting off automatically.
Check for small leaks, if pump does not shut off automatically
after priming or pulses periodically when not in use.
2) Fully extend boom arms by pushing boom lever on
control pod to the full forward position.
If boom arms do not extend properly, check the
Troubleshooting area of this manual.
DO NOT leave unit unattended with knob in the position.
BASIC OPERATION
POWER UP UNIT EXTEND BOOM ARMS
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 13
BASIC OPERATION
SPRAY BOOM APPLICATION
1) Tilt unit backwards on wheels to a comfortable operator angle
and raise front of unit off ground, approximately 3 – 4 inches.
2) With unit energized (control knob in position), squeeze
orange trigger to spray de-icer from boom nozzles.
3) Push unit forward balancing on rear wheels only.
DO NOT push unit with front skids dragging on pavement.
This will result in uneven coverage of product and
unnecessary operator effort.
ENGLISHESPAÑOL
FRANÇAIS
14 | OSSIAN
DO NOT push unit with front skids dragging on pavement.
This will result in uneven coverage of product and
unnecessary operator effort
DO NOT apply anti-icing chemicals below 15˚ F.
Use dry ice melting chemicals at lower temperatures.
BASIC OPERATION
ANTI-ICING SIDEWALKS
1) Anti-ice sidewalk by pushing unit at a comfortable walking
pace while holding down spray trigger.
2) Watch pavement to insure even coverage.
Surface should be wet, not puddled.
The 4 foot wide spray pattern of
the Ossian LS® is optimized for
the width of a standard municipal
sidewalk.
The spray boom application rate
is pre-calibrated for 1 gal/1000 sqft.
No adjustment is necessary.
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 15
BASIC OPERATION
ANTI-ICING STAIRS
Wand application rate is different than spray boom.
Watch pavement surface to insure an even coating.
Surface should be wet not puddled.
DO NOT apply anti-icing chemicals below 15˚ F.
Use dry ice melting chemicals at lower temperatures.
1) Close boom arms if they are open and park Ossian LS on level
surface at bottom of stairs to insure unit will not roll during use.
2) Remove wand from holster and extend wand and enough hose
to reach top stair.
3) Starting at the top of the stairs, apply an even coating of
product working downward to the bottom stair.
Surface should be wet not puddled.
ENGLISHESPAÑOL
FRANÇAIS
16 | OSSIAN
BASIC OPERATION
SIDEWALK AND STEP APPLICATION BASIC CAUTIONS
Risk of slippery surface.
Slush must be removed from to prevent
refreezing that may result in a slip and fall.
DO NOT puddle de-icer product on sidewalk or
stairs. Puddled product will cause a tracking
issue and slip hazard.
Close/retract boom arms when not in use to
protect from damage.
DO NOT pull unit by wand hose. Damage to
unit could result.
DO NOT leave unit unattended with knob in
position.
Check for small leaks if pump does not shut
off automatically after priming or pulses
periodically when not in use.
WARNING
ENGLISH ESPAÑOL FRANÇAIS
www.ossian.com | 17
De-icing is the operation of removing residual ice and snow after an area
has been cleared with mechanical means.
1) After snow has been mechanically removed by blade, snow
blower or other equipment, the Ossian LS® can be used to
apply liquid de-icer to the residual ice and snow left behind with
standard application rates.
2) Slush created by the combination of de-icer and snow must be
removed to prevent refreezing where it can cause a dangerous,
uneven and slick surface.
Risk of slip and fall accident.
Remove slush from de-iced surfaces to prevent refreezing.
DO NOT use liquid anti-icers to melt ice and snow prior to
physical snow removal or as a substitute for snow removal.
BASIC OPERATION
DE-ICING APPLICATION
WARNING
ENGLISHESPAÑOL
FRANÇAIS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Ossian LS Assembly And Operation Manual

Taper
Assembly And Operation Manual

dans d''autres langues