AMS Wireless Vibration Monitor Mode d'emploi

Taper
Mode d'emploi
Emerson
Reliability Solutions
835 Innovation Drive, Knoxville, TN 37932 USA
+1 865 675 2400
+1 865-218-1401
www.emerson.com/ams
©2020, Emerson.
The contents of this publication are presented for
informational purposes only, and while every effort has
been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their
use or applicability. All sales are governed by our terms and
conditions, which are available on request.
We reserve the right to modify or improve the designs
or specifications of our products at any time without notice.
All rights reserved. AMS is a mark of one of the Emerson
group of companies. The Emerson logo is a trademark and
service mark of Emerson Electric Co. All other marks are the
property of their respective owners.
Device Preparation
For safety reasons, the device is shipped with the battery
disconnected. When you are ready to configure the device,
follow the steps below to reconnect the battery.
1. Use your hands to unscrew and remove the blue cover.
2. Remove the battery with the pull tab.
3. Locate the battery connector and plug it into the
socket on the device as shown.
4. Replace the battery. Tuck the wires against the battery
and lock them into place.
Quick Configuration
1. Locate the terminals for the communication port
on the opposite side of the device.
2. Connect a configuration device to the terminals such
as a computer running AMS Device Manager with a
HART
modem or an AMS Trex Field Communicator
(shown below).
3. Follow the onscreen instructions to configure the
device. It is advisable to use the option for Guided
Setup. Individual parameters can be easily customized
later using AMS Device Manager after the device has
joined the wireless network.
4. After configuring the device, make sure to disconnect
the battery before replacing the cover. This not only
conserves battery power, but the battery will need to
be removed again when using the recommended field
installation method.
This document is intended to provide basic information about
installation and configuration as well as information regarding
safety and approvals. For more information, please reference
the User Guide (P/N MHM-97927-PBF) on the Emerson website.
Safety Information
For personal and system safety, and for optimum product
performance, care should be given to read and understand the
user documentation before installing, using, or maintaining
this device. For more information, see the AMS Wireless
Vibration Monitor User Guide.
For questions, contact customer support:
Inside US (Toll free): 1-800-999-9307
or 1-800-654-7768,
International: 1-(952) 906-8888,
Battery Information
The AMS Wireless Vibration Monitor uses a standard battery.
For safety reasons, however, the unit was shipped to you with
the battery disconnected. You will need to connect the battery
before configuring and installing the device.
Replacing the battery
The battery may be replaced in hazardous locations.
Replace the battery only with Tadiran Part Number TL-4920/VE
or Emerson Part Number A0702PPU. Follow the instructions
in the User Guide for replacing the battery.
Installation Considerations
When choosing an installation location and position, consider
the need for access to the device. For best overall performance,
the device should be installed vertically. If it is necessary to
install the device horizontally pay special attention to the
network arrangement.
Installation in Hazardous Areas
The device is covered by a hazardous area rating. It is the
responsibility of the user to verify that the device has the
necessary approvals required for the intended area of use.
Warning: Installation in an explosive environment must be in
accordance with the appropriate local, national, and international
standards, codes, and practices. Please review this document for
any restrictions associated with safe installation.
Temperature Limits
As a safety precaution, the following limits must be observed
for ambient temperature:
1. Storage Temperature :–40 to 185 °F / –40 to 85 °C
2. Operating Temperature: –40 to 185 °F / –40 to 85 °C
General Notice
If the device has been exposed to a hazardous substance, a
Safety Data Sheet (SDS) must be included with the returned
materials. An SDS is required by law to be available to people
exposed to specific hazardous substances.
AMS Wireless
Vibration Monitor
QUICK USER GUIDE
Field Installation
1. To stud mount the device (recommended),
prepare the machine surface using a spot face tool.
Then drill and tap a ¼-28” hole 0.25” (6.35mm) deep.
Alternately, a mounting pad with ¼-28” thread can be
glued in place using epoxy. (Consult the User Guide
for additional mounting options and instructions.)
2. With the cover still on the device, use your hand
to loosely screw the device into the threaded hole.
Do not tighten.
3. Remove the cover and battery.
4. Insert a small screwdriver through the guide hole in the
base of the unit (shown below) and use this to hold the
device in the desired orientation.
5. While maintaining the device orientation, use a 3/16”
ball driver to tighten the captive screw in the center
of the base (shown above) to 2-5 ft-lb.
6. Then connect and replace the battery.
7. Use your hand to replace and tighten the cover.
Shipping Considerations
Contact Emerson Product Support to obtain a Return
Materials Authorization (RMA) number and receive
additional instructions.
Primary lithium batteries are regulated in transportation by
the U.S. Department of Transportation, and are also covered
by IATA (International Air Transport Association), ICAO
(International Civil Aviation Organization), and ADR
(European Ground Transportation of Dangerous Goods).
It is the responsibility of the shipper to ensure compliance with
these or any other local requirements. Please consult current
regulations and requirements before shipping.
Product Certifications
The AMS Wireless Vibration Monitor has a number of
certifications and approvals including CE, FCC, ISED, RED, CSA,
and ATEX. For a complete list of product certifications, see
http://www.emerson.com/AMSVibrationMonitor.
MHM-97928-PBF, Rev 1
August 2020
DRAWING NO./PART NO. SCALE
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES
DECIMALS: .X ± .030
.XX ± .020
.XXX ± .010
FRACTIONS: ± 1/32
± 0°-30'ANGULAR:
FINISH:
DO NOT SCALE THIS DRAWING
DATEDES IGN ED BY:
DATE
DRAWN BY:
DATE
LAST REVISED BY:
DATE
RESP. ENGINEER
DATE
MANUFACTURING ENG.
DATEDOCUMENTCONTROL
Knoxville, TN.
TITLE
CAD F ILENAME
FIRST USED MODELNO.
OF
SHEET
MATERIAL:
FIN ISH:
1
ART WO R K FIL ENA ME/ REVISION LEVEL:
For Reference Only
THIS DRAWING IS PROPERTY OF AND PROPRIETARY TO EMERSON. THIS DRAWING AND
THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED NOR DISCLOSED TO
ANYONE EXCEPT THOSE REQUIRI NG ITS USE FOR EMERSON AUTHORIZED PURPOSES.
THIS DOCUMENT SHALL BE DESTRO YED OR RETURNED TO EMERSON WHEN NO LONGER
REQUIRED FOR THOSE PURPOSES.
D25902
D25902
1
A9530 CSA, IECEx,
ATEX Ins talla tion Instructions
9530
J. Clemons 08-Oct-2019
J. Clemons 08-Oct-2019
J. Clemons 08-May-2020
J. Baldwin
T. Rogers
32
DATEECO NO.REV
01 Initial Release 08-May-2020
AMS Model A9530 Wireless Vibration Monitor:
Power Options:
Battery must be replaced only with Tadiran Part Number: TL-4920/VE
or Emerson Par t Number: A0702PPU
NOTE: Approved battery may be replaced in approved hazardous
locations per this drawing.
CSA-C/US CSA20CA80026524
Class I Division 1 Groups A,B,C & D
Class I Zone 0 AEx / Ex ia IIC T4 Ga
-40°C
< Ta < 85°C;
Type 4X Enclosure
ATE X CSANe 20ATEX2042X
2813 II 1 G Ex ia I IC T4 Ga (135°C)
-40°C
< Ta < 85°C
IECEx CSA 20.0002X
Ex ia IIC T4 Ga
Ta: -40°C to +85°C
Agency approved drawing. No changes
without prior agency a pproval.
Warnings:
1. Care should be taken to protect this device from impact or
abrasion if located in a zone 0 environment.
2. Substitution of components may impair intrinsic safety.
3. The battery may present a potential electrostatic ignition
hazard. Use Caution when replacing the battery
.
Avertissements:
1. Des précautions doivent être prises pour le protéger des
chocs ou de l'abrasion s'il est situé dans un environnement de
zone 0.
2. La substitution de composants peut compromettre la sécuri
intrinsèque.
3. La batterie peut présenter un risque potentiel d'allumage
électrostatique. Soyez prudent lors du remplacement de la
batterie.
161047
Conditions of Safe Use:
1. Shall be powered only by C-sized lithium primary cell type TL-4920/VE
manufactured by Tadiran or Emerson Part Number A0702PPU.
2. HART Terminal Entity parameters:
Uo = 5.84 V, Io = 116mA, Po = 329mW, Co = 0.1µF, Lo = 5mH;
Ui = 5.27 V, Ii = 5mA, Pi = 6.6mW, Ci = 13µF, Li = 0.022mH
3. The device may be configured using the HART terminals only by 375, 475, or
TREX field communicators.
4. Under certain extreme circumstances, the non-metallic parts incorporated in
the enclosure of this equipment may generate an ignition-capable level of
electrostatic di scharge. Therefore, the equipment shall not be installed in a
location where the external conditions are conductive to the build-up of
electrostatic charge on such surfaces. In addition, the equipment shall only be
cleaned with a damp cloth.
5. The device shall be installed on an earthed metal frame.
Conditions d'utilisation sûre:
1. Ne doit être alimenté que par une cellule primaire au lithium de taille C de type
TL-4920 / VE fabriquée par Tadiran ou Emerson Part Number A0702PPU.
2. Paramètres de l'entité du terminal HART:
Uo=5,84V,Io=116mA,Po=329mW,Co=0,F,Lo=5mH;
Ui=5,27V,Ii=5mA,Pi=6,6mW,Ci=1F,Li=0,022mH
3. L'appareil ne peut être configuré à l' ai de des terminaux HART que par des
communicateurs de terrain 375, 475 ou TREX.
4. Dans certaines c i rcons tanc es extrêmes, les pièces non talliques
incorporées dans le boîtier de cet équipement peuvent générer un niveau de
décharge él ectrostatique capable d'allumage. Par conséquent, l'équipement ne
doit pas être installé dans un endroit les conditions externes conduisent à
l'accumulation de charges électrostatiques sur de telles surfaces. De plus,
l'équipement ne doi t être nettoyé qu'avec un chiffon humide.
5. L'appareil doit être installé sur un cadre métallique mis à la terre.
Country Approva l Status
Brazil PENDING
Canada IC: 3434A-A9530M1
Ecuador PENDING
Hong Kong PENDING
Japan PENDING
Mexico PENDING
Philippines PENDING
Serbia PENDING
Singapore PENDING
South Africa PENDING
US NL5-A9530M1 Model: A9530V1, A9530V3
This product is approved for sale in many countries.
Please contact Emerson for a complete listing.
Radio Approvals
Wireless Certifications
Telecommunications compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product certification.
Emerson works with governmental agencies around the
world to supply fully compliant products and remove the
risk of violating country directives or laws governing
wireless device usage.
Radio Equipment Directive (2014/53/EU)
Emerson complies with the Radio and Equipment Directive.
FCC approvals
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to a radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
• This device must be installed to ensure a minimum antenna
separation distance of 20cm from all persons
CAUTION
Changes or modification not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
ISED approvals
This device contains licence-exempt transmitter(s)/receiver(s)
that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including
interference that may cause undesired operation
of the device.
Cet appareil contient des émetteurs / récepteurs exemptés
de licence qui sont conformes aux RSS exempts de licence
d’Innovation, Sciences et Développement économique Canada.
Son fonctionnement est soumis aux deux conditions suivantes:
1. Cet appareil ne doit pas provoquer d’interférences.
2. Cet appareil doit accepter toute interférence,
y compris les interférences pouvant entraîner un
fonctionnement indésirable de l’appareil.
  • Page 1 1
  • Page 2 2

AMS Wireless Vibration Monitor Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues