QSC Audio CX502 Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur
EN
CH
DE
FR
ES
CX Series User Manual
Installed Sound Professional Audio Amplifiers
2-Channel Low-impedance Models:
CX302
CX502
CX702
CX902
CX1102
4-Channel Low-impedance Models:
CX254
CX404
70 Volt Direct Output Models:
CX204V (4-channel)
CX302V (2-channel)
CX602V (2-channel, 8 ohm capable)
CX1202V (2-channel, 4 and 8 ohm capable)
*TD-000077-00*
TD-000077-00 Rev.E
EN
2
Important Safety Precautions & Explanation of Symbols
1- Read these instructions.
2- Keep these instructions.
3- Heed all warnings.
4- Follow all instructions.
5- WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture. Do not use this apparatus near water.
6- Clean only with a dry cloth.
7- Do not block any ventilation openings.
8- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.
A grounding plug has two blades and a grounding prong. The wide blade or third prong are provided for your safety. If the provided plug
does not fit your outlet, consult an electrician for the replacement of the obsolete outlet.
10- Protect the power cord from being walked on or pinched, particularly plugs, convenience receptacles, and the point where they exit
from the apparatus.
11- Use only attachments/accessories specified by QSC Audio Products, Inc.
12- Use only with hardware, brackets, stands, and components sold with the apparatus or by QSC Audio Products, Inc.
13- Unplug the apparatus during lightning storms or when unused for long periods of time.
14- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally, or has been dropped.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and main-
tenance (servicing) instructions in this manual.
The lightning flashes printed next to the OUTPUT terminals of the amplifier are intended to alert the user to the risk of hazardous
energy. Output connectors that could pose a risk are marked with the lightning flash. Do not touch output terminals while amplifier
power is on. Make all connections with amplifier turned off.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsu-
lated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock
to humans.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED PERSONNEL.
WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture.
FCC INTERFERENCE STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in accordance to the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by switching the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio or TV technician for help.
© Copyright 2005, QSC Audio Products, Inc.
QSC® is a registered trademark of QSC Audio Products, Inc.
"QSC" and the QSC logo are registered with the U.S. Patent and Trademark Office
All trademarks are the property of their respective owners.
EN
3
Introduction
Thank you for purchasing this QSC power amplifier. Please read the following directions to obtain the best results.
The CX model line-up features:
•2 channel and 4 channel low-impedance or transformerless 70V output models
•Each channel pair has its own DataPort and Mode Switch
•QSC DataPorts connect to the most advanced QSC accessories and monitoring systems
•Mode switches for Clip Limit, Low Frequency Filter, Stereo, Bridge Mono, and Parallel Inputs
•QSC PowerWave high-performance, compact, and light weight switching power supply
•Complete amplifier protection and monitoring
•Barrier strip output connectors
•XLR and terminal block balanced input connectors
•Gain controls are recessed and detented
•Security cover for gain controls prevents tampering
•Active inrush current limiting eliminates need for power sequencing
•LED indicators for power, parallel or bridge mode, input signal presence, -20dB, -10dB, and clip/protect
•Optional front panel handles
•Optional IT-42 isolated output transformer for CX302 for 25V, 70V, and 100V (or 50V, 140V, and 200V bridge mode)
Unpacking
Factory packed carton contains:
•CX amplifier
•User's manual
•Security cover for gain controls
•Adhesive rubber feet (for non-rack mount applications)
•3-pin terminal block input connectors
•Spade lug output connectors
•IEC-type detachable power cord
Use the same type carton when shipping the amplifier.
Front Panel
(CX404 shown, other models similar)
1- Power Switch
2- Cooling Air Exhaust Vents
3- LED Indicators
4- Security Panel Retaining Screw
5- Gain Controls
6- Security Panel Retaining Slots
EN
4
Rack Mounting
Optional handles shown. Use four screws and washers to mount
the amplifier to the equipment rack rails. To use the
amplifier outside a rack, attach the self-adhesive
rubber feet to the bottom.
Cooling
Air flows from the rack, into the back of the amplifier,
and out the front. This keeps the rack cool. The fan
automatically runs faster when the amp is working
hard.
Do not block the front or rear air vents!
AC Mains Connection
Connect AC power to the IEC socket on the back of the amplifier. NOTE: Turn off the AC power switch before connecting AC power. The
AC Switch must be turned on to use remote control systems or the Standby function.
The correct AC line voltage is shown on the serial number label, on the rear panel. Connecting to the wrong line volt-
age may damage the amplifier or increase the risk of electric shock.
Air flow in QSC amplifiers: Cool air is drawn
into the rear of the amplifier by the cooling fan.
Warm air exits the front of the amplifier.
1- CH1 Terminal Block Input Connectors
2- DataPort Connector
3- CH2 Terminal Block Input Connectors
4- Mode Switches
5- Barrier Strip Output Connectors
6- Cooling Air Inlet Vents
7- Mode Switch Setting Diagrams
8- IEC Power Connector
Rear Panel
(CX404 shown, other models similar, 2-Ch. models equipped with XLR inputs as well)
EN
5
Stereo Mode - Switches 4, 5, 6
and 7 are all set to the DOWN
position.
Parallel Mode - Switches 4, 5,
and 6 are set to the UP position.
Switch 7 is set to the DOWN
position.
Bridge Mode- Switches 4, 5, 6
and 7 are all set to the UP posi-
tion.
Low Frequency Filter (“V” model
shown): Each channel has its
own switches for LF filter on/off
and frequency selection.
•The first channel uses switches
2,3. The second channel uses
switches 8,9.
•Switches 3 and 8 turn the LF fil-
ter ON or OFF.
•Switches 2 and 9 select 33/75 Hz
(low Z) or 50/75 Hz (“V” models)
or 75 Hz.
•On four-channel models, the
second mode switch has
switches for Ch.3 and Ch.4
Setting the Mode Switches
Two-Channel Models: One mode switch controls each channel’s indepen-
dent clip limiting and low frequency (LF) filtering. The switches can set the
amplifier’s operating mode for Stereo, Parallel, or Bridge operation.
Four-Channel Models: There are two mode switches; one controls the
operation of channels 1-2, the other controls the operation of channels 3-4.
It is not possible to bridge or parallel channels 1 or 2 with channels 3 or 4.
Setting Clip Limiters
Each channel has a clip limiter with its own on-off switch. The limiter only
responds to actual clipping, and automatically compensates for load and
voltage variations. Clip limiting is generally recommended, especially to
protect high frequency drivers.
Set switch UP (ON position) to use Clip Limiting.
Switch 1 controls the first channel.
Switch 10 controls the second channel.
Selecting Stereo, Parallel, or Bridge Mode
Each of the channel pairs can be set for normal Stereo operation, Parallel
Input mode, or Bridge Mono mode. On four-channel models, Ch.1 can be
bridged or paralleled with Ch.2; Ch.3 can be bridged or paralleled with Ch.4.
Stereo Mode- Each channel within the pair remains independent, and
each may be used for a different signal.
Parallel Mode - This setting connects both inputs of a pair together. One
signal feeds both channels. Do not connect different sources to each input.
Each channel's Gain control and speaker connection remain independent.
Bridge Mode- This setting combines both channels of a pair into a single
channel with twice the output voltage. Use only the first channel's input
and Gain control. Set the second channel's Gain control at minimum.
Do not connect different inputs to each side of a channel pair
when operating in parallel or bridge mode.
Setting Low Frequency Filters
Each channel has a 12dB per octave Low Frequency filter that can be set on
or off. Low impedance models can be set for 33 or 75 Hertz and distributed
output (“V” models) for 50 or 75 Hertz to prevent saturation of the 70V
speaker transformers. This reduces distortion and prevents amplifier over-
load.
Low Impedance Models: The filter should only be turned off for driving
subwoofers. The 33 Hz setting usually works well with loudspeakers that
have large LF drivers (12” or larger). The 75 Hz setting works well with com-
pact (smaller size) loudspeakers. Check the loudspeaker’s specifications and
select the setting closest to the loudspeaker’s low frequency capability.
High Impedance (“V”) Models: The filter should only be turned off for
driving subwoofers with special low frequency transformers. The 50 Hz set-
ting usually works well with high quality speaker transformers. The 75 Hz
setting works well with speech-grade speakers and transformers.
Each channel has its own switch
for Clip Limiter on/off.
The first channel uses switch 1.
The second channel uses switch
10. On four-channel models, the
second mode switch has
switches for Ch.3 and Ch.4
Typical Mode Switch block as
seen from the rear of the amplifier
(CX404V model shown).
EN
6
DataPort
Two-channel models have one DataPort, four-channel models have two DataPorts (one Ch.1-2, one for Ch.3-4).
The DataPort connects to optional QSC accessories and processing devices. DataPort devices provide remote
Standby control, monitoring, DSP processing, filter and crossover functions. The CX’s DataPort supports the full
"V1" DataPort feature set. Two-channel models support directly-mounted DSP “modules”. Four channel models
require remote mounting of accessory modules connected with DataPort cables.
Each DataPort connects to its respective channel pair; Ch.1-2 or Ch.3-4. Each channel pair may use its DataPort
or the Terminal Block inputs. When using the DataPort, do not connect to that channel's Terminal Block inputs.
Amplifier Standby is controlled only by the Ch.1- 2 DataPort.
DataPort Tips:
1- DataPort 1-2 controls Standby for the entire amplifier. The AC switch must be turned ON before the DataPort
can control the power.
2- Each DataPort controls and monitors the signals to its respective channel pair (Ch.1-2, Ch.3-4).
3- Do not use the Bridge Mono or Parallel mode switches when using DataPort Inputs. The signal level may be reduced. For more infor-
mation, see the Owner's Manual for the DataPort device.
4- A DataPort device is normally used to control the signal gain before entering the amplifier. Set the front panel Gain controls at max-
imum after confirming correct operation. If desired, install the protective cover to prevent tampering.
5- Each channel uses a separate internal heat sink. The heat sink temperatures are reported on that pair's DataPort.
6- Consult your QSC dealer or the QSC web site for the latest DataPort products.
Inputs
Each channel has a balanced 3-pin terminal block input. Two channel models also feature XLR inputs. The input impedance is 12k ohm
balanced or 6k ohm unbalanced. A set of terminal block connectors is included in the carton. Terminal block wiring is connected with
simple hand tools, and inputs can be changed quickly. XLR inputs are connected with standard cables and can be changed quickly.
Pinouts are marked on the rear panel.
Balanced connections are recommended to reduce AC hum and interference, especially with long cable runs. Unbalanced connections
may be suitable for short cables. The signal's source impedance should be less than 600 ohms. If the DataPort is being used for input
signals, do not connect cables to the terminal blocks.
Terminal Block Connectors
Balanced inputs: Strip the wires ¼ inch (6mm) and connect to the plug
as shown. Be sure to tighten the screws firmly.
Unbalanced inputs: Strip the wires ¼ inch (6mm) and connect to the
plug as shown. The middle pin must be connected to the shield pin as
shown. Be sure to tighten the screws firmly.
XLR Inputs (2-Ch. models only)
Balanced inputs: Connect to the plug as shown.
Unbalanced inputs: Connect to the plug as shown.
Pin 3 and pin 1 must be connected with a jumper as
shown.
DataPorts on a 4-Ch. amplifier.
EN
7
70V stereo or parallel
connection- Each 70V
zone connects to its
respective channel.
Ensure that all speaker
connections maintain
proper polarity.
140V Bridge connection-
Wire each bridged pair to
a 140V circuit as shown.
Check for proper polarity.
Outputs
Wiring connections are shown on the back of the chassis. Carefully note the
polarity marks, which are arranged to make Bridge Mode connections easier.
Four-channel models are shown in the examples; two-channel models are similar.
OUTPUT TERMINAL SAFETY WARNING! Do not touch output termi-
nals while amplifier power is on. Make all connections with ampli-
fier turned off. Risk of hazardous energy!
Low Impedance Outputs
Stereo and Parallel Mode- Connect each loudspeaker to its own channel of
the amplifier, as shown on the chassis label. The mode configuration switches
must be set for Stereo or Parallel mode.
Bridge Mode- Bridge mode configures the channel pair to drive a single high-
power loudspeaker load. The mode configuration switches must be set for Bridge
mode. Use only the first channel's input and Gain control. Set the second chan-
nel's Gain control at minimum.
Distributed Outputs (“V” models, 70V/140V)
Stereo and Parallel Mode- Connect each 70V circuit to its own channel of the
amplifier, as shown on the chassis label. The mode configuration switches must
be set for Stereo or Parallel mode.
70V Output- Risk of hazardous energy! Class 2 wiring shall be used
for 70V outputs.
Bridge Mode- Bridge mode configures the channel pair to drive a single 140V
audio circuit. The mode configuration switches must be set for Bridge mode. Use
only the first channel's input and Gain control. Set the second channel's Gain
control at minimum. Connect the load as shown on the chassis label.
140V BRIDGE MODE PRECAUTIONS:
Class 3 Wiring shall be used for bridged mono 140V outputs.
Connect only 140V distributed audio circuits in bridged mode. Do not
use 70V loads in bridge mode! Use Stereo or Parallel mode channels
to drive 70V loads. 140V is the minimum for bridge mode operation.
Low Impedance Stereo or
Parallel Connection- Each
loudspeaker load con-
nects to its respective
channel. Four channel
model shown. Ensure that
all speaker connections
maintain proper polarity.
Low Impedance Bridge
Connection- Each loud-
speaker load connects to a
bridged channel pair. Four-
channel model shown.
Check for proper polarity.
Loads Rated by Model
Be sure the model
amplifier you are using
is rated for the load!
An asterisk (*)indicates the
model is rated for the load.
(S/P)= Stereo/Parallel mode
(Br.)= Bridge mode
EN
8
LED Indicators
The LED indicators can be used to monitor system operation and identify common prob-
lems.
POWER: GREEN, above the BRIDGE (BRDG) and PARALLEL (PAR) indicators.
Normal indication: AC switch ON: LED will illuminate.
If no indication: Check AC power cord and AC outlet. Confirm that DataPort 1-2 is
not holding the amp in 'Standby' mode.
CLIP: RED, adjacent the channel number markings.
Normal indication: illuminates whenever the amplifier is driven beyond full power.
The resulting distortion corresponds to the brightness of the LED. Distortion that
causes only brief flashing may not be audible.
-During muting, the LED fully illuminates. This occurs during normal "On-Off" muting.
Abnormal indication:
-Bright red illumination while the amp is being used indicates either thermal muting
or a shorted output.
-If the amplifier overheats, the fan will run at full speed, and operation should resume
within one minute. Allow the fan to run, and make sure the amplifier ventilation is
adequate.
-A shorted or overloaded output circuit will cause excessive Clip flashing and possible
overheating.
If distortion is audible without a Clip indication, the problem is either before or after
the amplifier. Check for damaged speakers or overloaded signal source. The amplifier
Gain control should be in the upper half of its range to prevent input overload.
SIGNAL, -20dB, -10dB: GREEN, under each Clip LED.
Normal indication: The SIGNAL indicator illuminates when the input signal exceeds
-35 dB, the -20dB indicator illuminates when the signal exceeds -20dB, and the -10dB
indicator illuminates when the signal exceeds -10dB.
If no indication: check Gain settings and increase gain if necessary. Check input con-
nections and audio source for signal. If the Clip LED illuminates with little or no Signal
indication, check the output wiring for shorts.
Abnormal indication: If the SIGNAL (SIG), -20dB, or -10dB LED illuminates with no
signal input, there may be system oscillations or some other malfunction. Disconnect
the load and fully reduce the gain. If the LED remains on, the amp may need servicing.
BRDG and PAR:
Each channel pair has a YELLOW LED for Bridge Mode, and an ORANGE LED for Paral-
lel mode. These show how the rear panel switches are set (see Setting the Mode
Switches). In Stereo mode, both LEDs should be OFF.
LED indicators on 2-channel models.
LED indicators on 4-channel models.
EN
9
Gain Controls
The Gain controls are recessed and can be adjusted with
a small screwdriver or flat tool. If desired, the Gain Con-
trol Security Cover can be installed to prevent changes
to the installer's settings.
Turn the gain controls clockwise to increase gain and
counter clockwise to decrease gain. The maximum volt-
age gain of the amplifier varies depending on the model
designation. Maximum voltage gain for each model is
shown on the front panel label in parentheses adjacent
the 0dB attenuation setting.
The Gain controls are marked in dB of attenuation. There
are 21 detents for repeatable adjustments. The upper 14
steps are about 1 dB each, and settings should normally
be made within this range. The range below -14 dB
should not be used for normal program levels, as the
input headroom could be exceeded, but can be used for
testing at reduced levels. At the minimum setting, the
signal is completely cut off.
Gain Control Security Plate
The cover blocks access to the Gain settings. The LED
indicators are still visible to monitor the system's opera-
tion.
1. Use a 9/64" or 3.5 mm hex driver to loosen the screw
several turns. Do not remove it completely.
2. Slide the right end of the cover under the loosened
screw.
3. Insert the left end tabs into the last row of ventilation
slots, and slide the panel fully to the right. It should
lock into the slots.
4. Confirm that the LED's are visible through the cover.
Tighten the hex screw carefully.
Gain controls on 2-channel models.
Markings will vary depending on model.
Gain controls on 4-channel models.
Markings will vary depending on model.
CX902 shown with gain control security plate installed.
EN
10
Specifications 2-Channel Low-Impedance Models
CX302 CX502 CX702 CX902 CX1102
OUTPUT POWER (Watts)
20 - 20k Hz, 0.03% THD, 8 Ohms/Ch. 200 300 425 550 700
20 - 20k Hz, 0.05% THD, 4 Ohms/Ch. 325 500 700 900 1100
1k Hz, 1.0% THD (EIA), 8 Ohms/Ch. 215 325 475 625
1k Hz, 1.0% THD (EIA), 4 Ohms/Ch. 375 550 825 1050
1k Hz, 1.0% THD (EIA), 2 Ohms/Ch. 600 800 1200 1500 1700
Bridge Mono, 20 - 20k Hz, 0.1% THD, 16 Ohms 400 600 850 1100 1400
Bridge Mono, 20 - 20k Hz, 0.1% THD, 8 Ohms 700 1000 1500 2000
Bridge Mono, 1k Hz, 1.0% THD, 8 Ohms
Bridge Mono, 1k Hz, 1.0% THD, 4 Ohms 1200 1600 2400 3000 3400
DISTORTION, SMPTE-IM <0.01% <0.01% <0.02% <0.02% <0.02%
FREQUENCY RESPONSE 20 - 20k Hz, ±0.2dB at 10dB below rated output power, all models (-3dB points: 8 Hz and 100 kHz)
SIGNAL to NOISE, unweighted, 20 - 20k Hz -106 dB -107 dB -106 dB -104 dB -106 dB
VOLTAGE GAIN 31.5x (30dB) 40.0x (32dB) 50.5x (34dB) 56.6x (35dB) 56.6x (35dB)
INPUT SENSITIVITY, Vrms
for rated power into 8 Ohms 1.26 (+4.2dBu) 1.23 (+4.0dBu) 1.16 (+3.5dBu) 1.17 (+3.6dBu) 1.35 (+4.8dBu)
for rated power into 4 Ohms 1.14 (+3.4dBu) 1.12 (+3.2dBu) 1.05 (+2.6dBu) 1.06 (+2.7dBu) 1.17 (+3.6dBu)
OUTPUT CIRCUIT TYPE AB AB H H H
INPUT IMPEDANCE 6k ohms unbalanced, 12k ohms balanced, all models
DYNAMIC HEADROOM 2 dB at 4 Ohms, all models
DAMPING FACTOR >500 at 8 Ohms, all models
AMPLIFIER PROTECTION Short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads
COOLING Continuously variable speed fan; back-to-front air flow through heat sink tunnel
CONTROLS Front: AC POWER switch, gain controls (1 control per channel, 21 detents)
Back: 10-position DIP switch with Clip Limiter (1 per Ch.), LF Filter on/off (1 per Ch.)
LF filter select: 33 or 50 Hz (1 per Ch.), Stereo/Parallel/Bridge mode selection switches
LED INDICATORS POWER (green, 1 each), SIGNAL, -10dB, -20dB (green, 1 each per Ch.), CLIP (red, 1 each per channel),
BRDG and PAR (yellow, 1 each)
CONNECTORS Input: 3-pin terminal blocks ("euro" or "Phoenix" type) and XLRs (pin 2 positive)
Output: barrier strip connectors with protective shroud
Other: QSC DataPort connector (supports full “V1”feature set)
LOAD PROTECTION Turn-on/turnoff muting, AC coupling (DC fault blocking), Clip limiting.
POWER REQUIREMENTS Refer to rear panel serial number label. Configured at factory for 100, 120 or 220-240 VAC, 50- 60 Hz.
DIMENSIONS 19.0" (48.3 cm) W, 3.5" (8.9 cm) H, 14" (35.6 cm) D (from front mounting rails, including rear support ears)
WEIGHT 21 pounds (9.5 kg) net; 27 pounds (12.3 kg) shipping
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EN
11
Specifications 4-Channel Low-Impedance Models
CX254 CX404
OUTPUT POWER (Watts)
20 - 20k Hz, 0.03% THD, 8 Ohms/Ch. 170 250
20 - 20k Hz, 0.05% THD, 4 Ohms/Ch. 250
1k Hz, 1.0% THD (EIA), 8 Ohms/Ch.
1k Hz, 1.0% THD (EIA), 4 Ohms/Ch. 450
1k Hz, 1.0% THD (EIA), 2 Ohms/Ch. 450
Bridge Mono, 20 - 20k Hz, 0.1% THD, 16 Ohms 340 500
Bridge Mono, 20 - 20k Hz, 0.1% THD, 8 Ohms 500
Bridge Mono, 1k Hz, 1.0% THD, 8 Ohms 900
Bridge Mono, 1k Hz, 1.0% THD, 4 Ohms 900
DISTORTION, SMPTE-IM <0.01% <0.01%
FREQUENCY RESPONSE 20 - 20k Hz, ±0.2dB at 10dB below rated output power, all models (-3dB points: 8 Hz and 100 kHz)
SIGNAL to NOISE, unweighted, 20 - 20k Hz -106 dB -106 dB
VOLTAGE GAIN 29.0x (29dB) 36.5x (31dB)
INPUT SENSITIVITY, Vrms
for rated power into 8 Ohms 1.28 (+4.4dBu) 1.22 (+3.9dBu)
for rated power into 4 Ohms 1.08 (+2.9dBu) EIA: 1.16 (+3.5dBu)
OUTPUT CIRCUIT TYPE AB AB
INPUT IMPEDANCE 6k ohms unbalanced, 12k ohms balanced, all models
DYNAMIC HEADROOM 2 dB at 4 Ohms, all models
DAMPING FACTOR >500 at 8 Ohms, all models
AMPLIFIER PROTECTION Short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads
COOLING Continuously variable speed fan; back-to-front air flow through heat sink tunnel
CONTROLS Front: AC POWER switch, gain controls (1 control per channel, 21 detents)
Back: 10-position DIP switch (1 per channel pair) with Clip Limiter (1 per Ch.), LF Filter on/off (1 per Ch.)
LF filter select: 33 or 50 Hz (1 per Ch.), Stereo/Parallel/Bridge mode selection switches (1 set per Ch. pair)
LED INDICATORS POWER (green, 1 each), SIGNAL, -10dB, -20dB (green, 1 each per Ch.), CLIP (red, 1 each per channel),
BRDG and PAR (yellow, 1 each per Ch. pair)
CONNECTORS Input: 3-pin terminal block ("euro" or "Phoenix" type)
Output: barrier strip connectors with protective shroud, one barrier strip per Ch. pair
Other: two QSC DataPort connectors (supports full “V1”feature set), one DataPort per Ch. pair
LOAD PROTECTION Turn-on/turnoff muting, AC coupling (DC fault blocking), Clip limiting.
POWER REQUIREMENTS Refer to rear panel serial number label. Configured at factory for 100, 120 or 220-240 VAC, 50- 60 Hz.
DIMENSIONS 19.0" (48.3 cm) W, 3.5" (8.9 cm) H, 14" (35.6 cm) D (from front mounting rails, including rear support ears)
WEIGHT 21 pounds (9.5 kg) net; 27 pounds (12.3 kg) shipping
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EN
12
Specifications 2- and 4-Channel Distributed 70V Line Models
CX204V CX302V CX602V CX1202V
OUTPUT POWER (Watts)
20 - 20k Hz, 0.03% THD, 70V/Ch. 200 200 400 800
20 - 20k Hz, 0.03% THD, 8 Ohms/Ch. 550 700
20 - 20k Hz, 0.05% THD, 4 Ohms/Ch. 1100
1k Hz, 0.05% THD (EIA), 70V/Ch. 220 250 440 1000
1k Hz, 0.1% THD (EIA), 70V/Ch. 300 600 1200
1k Hz, 1.0% THD (EIA), 70V/Ch. 300
Bridge Mono, 140V, 20 - 20k Hz, 0.1% THD 400 400 800 850
Bridge Mono, 140V, 1k Hz, 0.1% THD 440 600 1200 2400
Bridge Mono, 1k Hz, 0.1% THD, 16 Ohms 1200 1400
Bridge Mono, 1k Hz, 0.1% THD, 8 Ohms 2300
DISTORTION, SMPTE-IM <0.02%, all models
FREQUENCY RESPONSE 20 - 20k Hz, ±0.2dB at 10dB below rated output power, all models (-3dB points: 8 Hz and 100 kHz)
SIGNAL to NOISE, unweighted, 20 - 20k Hz -106 dB. all models
VOLTAGE GAIN 56.6x (35dB) all models
INPUT SENSITIVITY, Vrms 1.26V (+4.2dBu) for rated power at 70.7V
OUTPUT CIRCUIT TYPE AB AB AB H
INPUT IMPEDANCE 6k ohms unbalanced, 12k ohms balanced, all models
DYNAMIC HEADROOM 2 dB at 4 Ohms, all models
DAMPING FACTOR >500 at 8 Ohms, all models
AMPLIFIER PROTECTION Short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads
COOLING Continuously variable speed fan; back-to-front air flow through heat sink tunnel
CONTROLS Front: AC POWER switch, gain controls (1 control per channel, 21 detents)
Back: 10-position DIP switch with Clip Limiter (1 per Ch.), LF Filter on/off (1 per Ch.)
LF filter select: 33 or 50 Hz (1 per Ch.), Stereo/Parallel/Bridge mode selection switches
LED INDICATORS POWER (green, 1 each), SIGNAL, -10dB, -20dB (green, 1 each per Ch.), CLIP (red, 1 each per channel),
BRDG and PAR (yellow, 1 each)
CONNECTORS Input: 3-pin terminal blocks ("euro" or "Phoenix" type)and XLRs (pin 2 positive)
Output: barrier strip connectors with protective shroud
Other: QSC DataPort connector (supports full “V1”feature set)
LOAD PROTECTION Turn-on/turnoff muting, AC coupling (DC fault blocking), Clip limiting.
POWER REQUIREMENTS Refer to rear panel serial number label. Configured at factory for 100, 120 or 220-240 VAC, 50- 60 Hz.
DIMENSIONS 19.0" (48.3 cm) W, 3.5" (8.9 cm) H, 14" (35.6 cm) D (from front mounting rails, including rear support ears)
WEIGHT 21 pounds (9.5 kg) net; 27 pounds (12.3 kg) shipping
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EN
13
Thermal Loss Table
This table provides typical thermal loss in BTU/
hr. and kcal/hr. for each model as a function of
load and output power level.
1/8 power (pink noise) represents typical pro-
gram with occasional clipping. Use this rating
for most applications.
1/3 power (pink noise) represents severe pro-
gram with heavy clipping.
Full power (sine) are continuous sine wave
driven at 1% clipping.
Thermal or overcurrent cutback limits duration
of full power 2 Ohm operation.
Current Draw Table (in Amperes)
This table provides typical current draw for each model as a
function of load and output power level. Units of measurement
are Amperes r.m.s.
NOTE! Current draw shown is for 120 VAC line. For 230
VAC models, multiply values shown by 0.5 .
1/8 power (pink noise) represents typical program with occa-
sional clipping. Use this rating for most applications.
1/3 power (pink noise) represents severe program with heavy
clipping.
Full power (sine) is continuous sine wave driven at 1% clipping.
Thermal or overcurrent cutback limits duration of full power 2
Ohm operation.
ES
14
Precauciones importantes de seguridad y explicación de los símbolos
1- Lea estas instrucciones.
2- Conserve estas instrucciones.
3- Observe todas las advertencias.
4- Siga todas las instrucciones.
5- ADVERTENCIA: Para prevenir incendios o descargas eléctricas, no exponga este equipo a la lluvia ni a la humedad. No use este aparato cerca del
agua.
6- Límpielo sólo con un paño seco.
7- No obstruya ninguna abertura de ventilación.
8- No lo instale cerca de fuentes de calor tales como radiadores, registros térmicos, estufas ni otros aparatos (inclusive amplificadores) que produzcan
calor.
9- No anule ningún elemento de seguridad de la clavija polarizada o de la clavija con conexión a tierra. Una clavija polarizada tiene dos hojas, una más
ancha que la otra. Una clavija con conexión a tierra tiene dos hojas y un terminal de conexión a tierra. La hoja ancha o el tercer terminal se
proporcionan para su seguridad. Si la clavija que se le proporciona no cabe en su tomacorriente, consulte con un electricista para reemplazar el
tomacorriente obsoleto.
10- Proteja el cable de alimentación para que no camine sobre él ni se le comprima, particularmente las clavijas, las tomas de corriente y el punto en
donde sale del aparato.
11- Use sólo piezas/accesorios especificados por QSC Audio Products, Inc.
12- Use sólo con herraje, soportes, estantes y componentes vendidos con el aparato o por QSC Audio Products, Inc.
13- Desenchufe el aparato durante tormentas eléctricas o cuando no lo vaya a usar durante periodos prolongados de tiempo.
14- Refiera todo el servicio a personal calificado. Es necesario dar servicio al aparato cuando sufra algún daño, como cuando se daña el cable de
alimentación eléctrica o la clavija, cuando se derraman líquidos o caen objetos sobre el aparato, cuando éste ha estado expuesto a la lluvia o humedad,
cuando no opere normalmente o cuando se haya caído.
El signo de exclamación dentro de un triángulo equilátero tiene la intención de alertar al usuario de la presencia de importantes instrucciones de
operación y mantenimiento (servicio) en este manual.
Los rayos impresos cerca de los terminales de SALIDA del amplificador tienen la intención de alertar al usuario del riesgo de energía peligrosa.
Los conectadores de salida que pudiesen representar un riesgo están marcados con el símbolo del rayo. No toque los terminales de salida
mientras el amplificador está encendido. Asegúrese de que todas las conexiones con el amplificador estén apagadas.
El símbolo del rayo con una punta de flecha dentro de un triángulo equilátero tiene la intención de alertar al usuario de la presencia de voltaje
"peligroso" no aislado dentro de la caja del producto, que puede ser de magnitud suficiente para constituir un riesgo de descarga eléctrica a los
seres humanos.
PRECAUCIÓN: PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA, NO QUITE LA CUBIERTA. EL INTERIOR NO CONTIENE PIEZAS A LAS QUE EL
USUARIO PUEDA DAR SERVICIO. REFIERA EL SERVICIO A PERSONAL CALIFICADO.
ADVERTENCIA: Para prevenir incendios o descargas eléctricas, no exponga este equipo a la lluvia ni a la humedad.
DECLARACIÓN DE LA FCC RESPECTO A LA INTERFERENCIA
NOTA: Este equipo ha sido probado y se ha determinado que cumple con los límites de un dispositivo digital Clase B, en virtud de la parte 15 de las reglas de la FCC. Estos
límites están diseñados para proporcionar protección razonable contra interferencia dañina en una instalación residencial. Este equipo genera, usa y puede irradiar
energía de radiofrecuencia, y si no se instala y usa de acuerdo con las instrucciones, puede causar interferencia dañina con las comunicaciones de radio. Sin embargo, no
hay garantía que no ocurrirá interferencia en una instalación en particular. Si este equipo causa interferencia dañina a la recepción de radio o televisión, lo cual se puede
determinar al apagar y encender el equipo, se recomienda al usuario que trate de corregir la interferencia en una o más de las siguientes maneras:
Reoriente o reubique la antena receptora.
Aumente la separación entre el equipo y el receptor.
Conecte el equipo en un tomacorriente de un circuito diferente al cual está conectado el receptor.
Consulte al distribuidor o a un técnico experimentado de radio o TV para solicitar ayuda.
© Copyright 2005, QSC Audio Products, Inc.
QSC® es una marca comercial registrada de QSC Audio Products, Inc.
“QSC” y el logotipo de QSC están registrados con la Oficina de Patentes y Marcas Comerciales de los Estados Unidos
Todas las marcas comerciales son propiedad de sus respectivos dueños.
ES
15
Introducción
Muchas gracias por la compra de este amplificador de potencia QSC. Por favor lea las siguientes instrucciones para obtener los mejores
resultados.
El modelo CX tiene las siguientes características:
•Modelos de salida de 70V de baja impedancia o sin transformadores de 2 y de 4 canales
•Cada par de canales tiene su propio conectador DataPort y conmutador de modo
•Los conectadores DataPort QSC conectan a los accesorios y sistemas de supervisión QSC más avanzados
•Conmutadores de modo para límite de recorte, filtro de baja frecuencia, y entradas estereofónicas, monopuenteadas y paralelas
•Suministro de potencia de conmutación QSC PowerWave de alto rendimiento, compacto y ligero
•Protección y control completos del amplificador
•Conectadores de salida con barra protectora
•Conectadores de entrada balanceada XLR y de bloque de terminales
•Los controles de ganancia están empotrados y con retenes
•La cubierta de seguridad de los controles de ganancia evita las alteraciones
•La limitación activa de la corriente de entrada elimina la necesidad de secuenciación de la potencia
•Indicadores LED de potencia, modo paralelo o puenteado, presencia de señal de entrada, -20dB, -10dB, y recorte/protección
•Asas opcionales para el panel frontal
•Transformador IT-42 de salida aislada para CX302 para 25V, 70V y 100V (o modo puenteado de 50V, 140V y 200V)
Desembalaje
La caja empacada en fábrica contiene:
•Amplificador CX
•Manual del usuario
•Cubierta de seguridad para los controles de ganancia
•Patas adhesivas de caucho (para aplicaciones de montaje que no sean en bastidor)
•Conectadores de entrada de tres patas al bloque de terminales
•Conectadores de salida de lengüeta de pala
•Cable de alimentación desprendible tipo IEC
Cuando embarque el amplificador utilice el mismo tipo de caja.
Panel frontal
(Se muestra el modelo CX404, es similar a otros modelos)
1- Conmutador de encendido
2- Ventilas de descarga del aire de enfriamiento
3- Indicadores LED
4- Tornillo de retención del panel de seguridad
5- Controles de ganancia
6- Ranuras de detención del panel de seguridad
ES
16
Montaje en bastidor
Se muestran las asas opcionales. Use cuatro tornillos y arandelas
para montar el amplificador en los rieles del bastidor del equipo.
Para usar el amplificador sin bastidor, instale las patas de
caucho autoadhesivas en la parte inferior.
Enfriamiento
El aire fluye desde el bastidor hacia el interior por la parte
posterior del amplificador y hasta afuera por la parte
frontal. Esto mantiene la rejilla fría. El ventilador
automáticamente funciona más rápido cuando el
amplificador está trabajando mucho.
¡No obstruya las ventilas frontales o posteriores!
Conexión a la línea principal de CA
Conecte la CA en el receptáculo IEC que se encuentra en la parte posterior del amplificador. NOTA: Apague el conmutador de CA antes de conectar
la CA. El conmutador de CA debe estar encendido para usar los sistemas de control remoto o la función de Espera.
El voltaje correcto de la línea de CA se muestra en la etiqueta del número de serie que se encuentra en el panel posterior. Si se
conecta un voltaje de línea incorrecto se puede dañar el amplificador o aumentar el riesgo de una descarga eléctrica.
Flujo de aire en los amplificador QSC: El aire frío
es arrastrado hacia el interior de la parte posterior
del amplificador por el ventilador de enfriamiento.
El aire caliente sale por el frente del amplificador.
1- Conectadores de entrada del bloque de terminales
del Canal 1
2- Conectador DataPort
3- Conectadores de entrada del Canal 2 al bloque de
terminales
4- Conmutadores de modo
5- Conectadores de salida con barra protectora
6- Ventilas de entrada del aire de enfriamiento
7- Diagramas para el ajuste del conmutador de modo
8- Conectador de potencia IEC
Panel posterior
(Se muestra el modelo CX404, los otros modelos son similares, los modelos de dos canales también están equipados con entradas XLR)
ES
17
Modo estéreo: Los conmutadores 4,
5, 6 y 7 todos están ajustados en la
posición HACIA ABAJO.
Modo paralelo: Los conmutadores
4, 5 y 6 están ajustados en la
posición HACIA ARRIBA.
El conmutador 7 está ajustado en la
posición HACIA ABAJO.
Modo puenteado: Los
conmutadores 4, 5, 6 y 7 todos están
ajustados en la posición HACIA
ARRIBA.
Filtro de baja frecuencia (se muestra
el modelo “V”): Cada canal tiene sus
propios conmutadores para la
activación/desactivación del filtro LF
y para la selección de frecuencia.
•El primer canal utiliza los
conmutadores 2,3. El segundo canal
utiliza los conmutadores 8,9.
•Los conmutadores 3 y 8 ENCIENDEN
o APAGAN el filtro LF.
•Los conmutadores 2 y 9 seleccionan
33/75 Hz (baja Z) o 50/75 Hz (modelos
“V”) o 75 Hz.
•En los modelos de cuatro canales, el
conmutador de segundo modo tiene
conmutadores para el canal 3 y para
el canal 4
Ajuste de los conmutadores de modo
Modelos de dos canales: Un conmutador de modo controla la limitación de
recorte independiente y la filtración de baja frecuencia (LF) de cada canal. Los
conmutadores pueden ajustar el modo de operación del amplificador en estéreo,
paralelo o en puente.
Modelos de cuatro canales: Hay dos conmutadores de modo; uno controla la
operación de los canales 1-2, y el otro controla la operación de los canales 3-4.
No es posible conectar en puente o en paralelo los canales 1 o 2 con los canales
3 o 4.
Ajuste de los limitadores de recorte
Cada canal tiene un limitador de recorte con su propio conmutador de
encendido y apagado. El limitador sólo responde al recorte real, y
compensa automáticamente las variaciones de carga y de voltaje.
Generalmente se recomienda la limitación de recorte, especialmente para
proteger excitadores de alta frecuencia.
Ajuste el conmutador HACIA ARRIBA (posición de ENCENDIDO) para usar la
limitación de recorte.
El conmutador 1 controla el primer canal.
El conmutador 10 controla el segundo canal.
Selección del modo Estéreo, Paralelo o Puenteado
Cada uno de los pares de canales se pueden ajustar para operar en modo estéreo
normal, modo de entrada en paralelo o modo monopuenteado. En modelos de
cuatro canales, el canal 1 se puede conectar en puente o en paralelo con el canal
2; el canal 3 se puede conectar en puente o en paralelo con el canal 4.
Modo estéreo: Cada canal dentro del par permanece independiente, y cada uno
se puede usar para una señal diferente.
Modo paralelo: Este ajuste conecta entre sí ambas entradas de un par. Una
señal alimenta ambos canales. No conecte fuentes diferentes a cada entrada. El
control de ganancia y la conexión del altavoz de cada canal permanecen
independientes.
Modo puenteado: Este ajuste combina ambos canales de un par en un solo
canal con dos veces el voltaje de salida. Use sólo la entrada y el control de
ganancia del primer canal. Ajuste el control de ganancia del segundo canal al
mínimo.
No conecte entradas diferentes a cada lado de un par de canales
cuando opere en modo paralelo o puenteado.
Ajuste de los filtros de baja frecuencia
Cada canal tiene un filtro de baja frecuencia de 12dB por octava que se puede
activar o desactivar. Los modelos de baja impedancia se pueden ajustar para 33 o
para 75 Hertzios y una salida distribuida (modelos “V”) para 50 o 75 Hertzios para
prevenir la saturación de los transformadores del altavoz de 70V. Esto reduce la
deformación y evita la sobrecarga del amplificador.
Modelos de baja impedancia: El filtro sólo se debe desactivar para accionar
los subwoofers. El ajuste de 33 Hz generalmente funciona bien con altavoces que
tienen excitadores LF (de 12” o más). El ajuste de 75 Hz funciona bien con
altavoces compactos (de menor tamaño). Revise las especificaciones de los
altavoces y seleccione el ajuste que sea más similar a la capacidad de baja
frecuencia del altavoz.
Modelos de impedancia alta (“V”): El filtro sólo se debe desactivar para
accionar los subwoofers con transformadores especiales de baja frecuencia. El
ajuste de 50 Hz usualmente funciona bien con transformadores de altavoces de
alta calidad. El ajuste de 75 Hz funciona bien con altavoces y transformadores de
calidad parlante.
Cada canal tiene su propio
conmutador para encender y apagar
el limitador de recorte.
El primer canal utiliza el conmutador
1. El segundo canal utiliza el
conmutador 10. En los modelos de
cuatro canales, el conmutador de
segundo modo tiene conmutadores
para el canal 3 y para el canal 4
Bloque típico del conmutador de
modo como se ve desde la parte
posterior del amplificador (se
muestra el modelo CX404V).
ES
18
DataPort
Los modelos de dos canales tienen un DataPort, los modelos de cuatro canales tienen dos DataPorts (uno para los
canales 1-2, uno para los canales 3-4). El DataPort se conecta a accesorios y dispositivos de procesamiento QSC
opcionales. Los dispositivos DataPort permiten el control remoto de la espera, el procesamiento DSP y las funciones de
filtrado y cruce. El DataPort del CX apoya todo el conjunto de características del DataPort "V1". Los modelos de dos
canales soportan "módulos" DSP directamente montados. Los modelos de cuatro canales requieren el montaje remoto de
módulos accesorios conectados con cables DataPort.
Cada DataPort se conecta a su respectivo par de canales; canales 1-2 o canales 3-4. Cada par de canales puede usar su
DataPort o las entradas del bloque de terminales. Cuando se use el DataPort, no lo conecte a las entradas del bloque de
terminales de ese canal. La espera del amplificador es controlada solamente por el DataPort de los canales 1-2.
Sugerencias sobre el DataPort:
1- El DataPort 1-2 controla la característica de espera para todo el amplificador. El conmutador de CA se debe ENCENDER antes de que el
DataPort pueda controlar la potencia.
2- Cada DataPort controla y supervisa las señales a su respectivo par de canales (canales 1-2, canales 3-4).
3- No utilice los conmutadores de modo monopuenteado o paralelo cuando utilice las entradas DataPort. Es posible que se reduzca el nivel de la
señal. Si desea más información consulte el Manual del Propietario del dispositivo DataPort.
4- Normalmente se usa un dispositivo DataPort para controlar la ganancia de la señal antes de que entre en el amplificador. Ajuste los controles
de ganancia del panel frontal al máximo después de confirmar la operación correcta. Si lo desea, instale la cubierta protectora para evitar
alteraciones.
5- Cada canal utiliza un disipador de calor interno separado. Las temperaturas del disipador de calor se reportan en el DataPort de ese par.
6- Consulte con su distribuidor QSC o visite el sitio Web de QSC para ver los últimos productos DataPort.
Entradas
Cada canal tiene una entrada balanceada de tres patas al bloque de terminales. Los modelos de dos canales también tienen entradas XLR. La
impedancia de entrada es de 12k ohmios balanceada o 6k ohmios no balanceada. En la caja se incluye un conjunto de conectadores del bloque de
terminales. El cableado del bloque de terminales está conectado con simples herramientas de mano, y las entradas se pueden cambiar
rápidamente. Las entradas XLR están conectadas con cables estándar y se pueden cambiar rápidamente. Los conjuntos de patas están marcados
en el panel posterior.
Se recomiendan conexiones balanceadas para reducir el zumbido y la interferencia de la CA, especialmente en tramos largos de cable. Las
conexiones no balanceadas pueden ser adecuadas para tramos cortos de cable. La impedancia de la fuente de la señal debe ser menor de 600
ohmios. Si el DataPort que se está usando es para señales de entrada, no conecte los cables en los bloques de terminales.
Conectadores del bloque de terminales.
Entradas balanceadas: Quite 1/4 de pulgada (6 mm) de aislamiento del
cable y conecte la clavija como se muestra Asegúrese de apretar firmemente
los tornillos.
Entradas no balanceadas: Quite 1/4 de pulgada (6 mm) de aislamiento del
cable y conecte la clavija como se muestra La pata central debe estar
conectada con la pata de blindaje como se muestra. Asegúrese de apretar
firmemente los tornillos.
Entradas XLR (solamente modelos de dos canales)
Entradas balanceadas: Conecte a la clavija como se muestra.
Entradas no balanceadas: Conecte a la clavija como se
muestra. La pata 3 y la pata 1 se deben conectar con un
puente como se muestra.
DataPort en un amplificador de 4 canales
ES
19
Conexión en estéreo o
paralelo de 70V: Cada zona
de 70V se conecta a su
canal respectivo.
Asegúrese de que todas las
conexiones del altavoz
mantengan la polaridad
adecuada.
Conexión puenteada de
140V: Conecte cada par
puenteado a un circuito de
140V como se muestra.
Revise que la polaridad sea
correcta.
Salidas
Las conexiones del cableado se muestran en la parte posterior del chasis. Note
detenidamente las marcas de polaridad, que están configuradas para facilitar las
conexiones del modo puenteado. En el ejemplo se muestran los modelos de cuatro
canales; los modelos de dos canales son similares.
¡ADVERTENCIA SOBRE LA SEGURIDAD DE LOS TERMINALES DE SALIDA!
No toque los terminales de salida mientras el amplificador está encendido.
Asegúrese de que todas las conexiones con el amplificador estén
apagadas. ¡Riesgo de energía peligrosa!
Salidas de baja impedancia
Modo estéreo y en paralelo: Conecte cada altavoz a su propio canal del amplificador,
como se muestra en la etiqueta del chasis. Los conmutadores de configuración de modo
deben ajustarse en modo estéreo o paralelo.
Modo puenteado: El modo puenteado configura el par de canales para que excite una
sola carga de alta potencia del altavoz. Los conmutadores de configuración de modo se
deben ajustar en el modo puenteado. Use sólo la entrada y el control de ganancia del
primer canal. Ajuste el control de ganancia del segundo canal al mínimo.
Salidas distribuidas (modelos “V”, 70V/140V)
Modo estéreo y en paralelo: Conecte cada circuito de 70V a su propio canal del
amplificador, como se muestra en la etiqueta del chasis. Los conmutadores de
configuración de modo deben ajustarse en modo estéreo o paralelo.
Salida de 70V: ¡Riesgo de energía peligrosa! Se debe usar un cableado
Clase 2 para las salidas de 70V.
Modo puenteado: El modo puenteado configura el par de canales para que excite a un
solo circuito de sonido de 140V/200V. Los conmutadores de configuración de modo se
deben ajustar en el modo puenteado. Use sólo la entrada y el control de ganancia del
primer canal. Ajuste el control de ganancia del segundo canal al mínimo. Conecte la
carga como se muestra en la etiqueta del chasis.
PRECAUCIONES CON EL MODO PUENTEADO DE 140V:
El cableado de Clase 3 se debe usar para las salidas monopuenteadas de
140V.
Conecte sólo circuitos de sonido distribuido de 140V en modo puenteado.
¡No use cargas de 70V en modo puenteado! Use los canales de modo
estéreo o paralelo para excitar cargas de 70 V. 140V es el mínimo para una
operación de modo puenteado.
Conexión en estéreo o en
paralelo de baja
impedancia: Cada carga de
altavoz se conecta a su
canal respectivo. Se muestra
el modelo de cuatro canales.
Asegúrese de que todas las
conexiones del altavoz
mantengan la polaridad
adecuada.
Conexión puenteada de baja
impedancia: Cada carga del
altavoz se conecta a un par
de canal puenteado. Se
muestra el modelo de cuatro
canales. Revise que la
polaridad sea correcta.
Cargas clasificadas por
modelo
¡Asegúrese de que el
amplificador modelo que
está usando esté
clasificado para la carga!
Un asterisco (*) indica que el
modelo está clasificado para la
carga.
(S/P)= Modo estéreo/paralelo
(Br.)= Modo puenteado
ES
20
Indicadores LED
Los indicadores LED se pueden usar para supervisar la operación del sistema e identificar
problemas comunes.
POTENCIA: VERDE, sobre los indicadores de PUENTE (BRDG) y PARALELO (PAR).
Indicación normal: Conmutador de CA ENCENDIDO: El LED se iluminará.
Si no hay indicación: Revise el cable de alimentación de CA y el tomacorrientes de CA.
Confirme que el DataPort 1-2 no esté reteniendo al amplificador en modo de 'Espera'.
RECORTE: ROJO, adyacente a las marcas de números del canal.
Indicación normal: Se ilumina siempre que el amplificador se excita a más de la potencia
total. La deformación resultante corresponde a la brillantez del LED. La deformación que
causa sólo un destello breve puede no ser audible.
-Durante el silenciamiento, el LED se ilumina completamente. Esto ocurre durante el
silenciamiento “Encendido-Apagado" normal.
Indicación anormal:
-Una iluminación roja brillante cuando el amplificador se está usando indica ya sea
silenciamiento térmico o una salida cortocircuitada.
-Si el amplificador se sobrecalienta, el ventilador funcionará a toda velocidad, y la operación
se debe reanudar en un lapso de un minuto. Permita el funcionamiento del ventilador y
asegúrese de que la ventilación del amplificador sea adecuada.
-Un circuito de salida cortocircuitado o sobrecargado causará destello excesivo de recorte y
posiblemente calentamiento excesivo.
Si la deformación es audible sin una indicación de recorte, el problema es ya sea antes o
después del amplificador. Revise si los altavoces están dañados o si la fuente de la señal
está sobrecargada. El control de ganancia del amplificador debe estar en la mitad superior
de su intervalo para evitar la sobrecarga de la entrada.
SEÑAL, -20dB, -10dB: VERDE, debajo de cada LED de recorte.
Indicación normal: El indicador de SEÑAL se ilumina cuando la señal de entrada excede -
35 dB, el indicador de -20dB se ilumina cuando la señal excede -20dB, y el indicador de -
10dB se ilumina cuando la señal excede -10dB.
Si no hay indicación: Revise los ajustes de ganancia y aumente la ganancia si es
necesario. Revise las conexiones de entrada y la fuente de audio para ver si hay señal. Si el
LED de recorte se ilumina con poca o nada indicación de señal, revise el cableado de salida
para ver si hay algún cortocircuito.
Indicación anormal: Si la SEÑAL (SIG), el LED de -20dB o el LED de -10dB se ilumina sin
entrada de señal, puede haber oscilaciones del sistema o algún otro mal funcionamiento.
Desconecte la carga y reduzca totalmente la ganancia. Si el LED permanece encendido, es
posible que el amplificador necesite servicio.
BRDG y PAR:
Cada par de canales tiene un LED AMARILLO para el modo de puenteado y un LED
ANARANJADO para el modo paralelo. Estos muestran la manera en que están ajustados los
conmutadores del panel posterior (véase Ajuste de los conmutadores de modo). En el modo
estéreo, ambos LED deben estar APAGADOS.
Indicadores LED en modelos de 2 canales.
Indicadores LED en modelos de 4 canales.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

QSC Audio CX502 Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur