Simplicity 030766-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

Manual No. 80083603 Revision A
Outdoor Inverter Generator
Operator’s Manual
Model Number _____________________________
Revision __________________________________
Serial Number ______________________________
Date Purchased ____________________________
Copyright © 2019. Briggs & Stratton Corporation
Milwaukee, WI, USA. All rights reserved.
800-743-4115
BRIGGSandSTRATTON.COM
EN2 BRIGGSandSTRATTON.COM
Equipment Description
Table of Contents
Equipment Description.........................2
Features and Controls .........................5
Operation....................................7
Maintenance ................................12
Storage ....................................15
FCC/IC Compliance Statement .................15
Troubleshooting/Specifications .................16
Warranty ...................................18
Register Your Product
To ensure prompt and complete warranty coverage, register
your product online at www.onlineproductregistration.com.
Symbols and Meanings
Signal Meaning
DANGER
Indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazard which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE
Indicates information considered important, but
not hazard-related.
Symbol Name Explanation
Safety Alert
Symbol
Indicates a potential personal injury
hazard.
Operator’s
Manual
Failure to follow warnings, instructions
and operator’s manual could result in
death or serious injury.
Toxic
Fumes
Engine exhaust contains carbon
monoxide, a poisonous gas that will
kill you in minutes. You cannot smell
it or see it.
Fire
Fuel and its vapors are extremely
flammable which could cause burns or
fire resulting in death or serious injury.
Engine exhaust could cause fire
resulting in death or serious injury.
Electric
Shock
Generator could cause electrical
shock resulting in death or serious
injury.
Hot Surface
Muffler could cause burns or
resulting in serious injury.
WARNING! This product can expose you to
chemicals including gasoline engine exhaust, which is
known to the State of California to cause cancer, and
carbon monoxide, which is known to the State of California to
cause birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
Equipment Description
Read this manual carefully and become familiar
with your outdoor generator. Know its applications,
its limitations, and any hazards involved. Save
these original instructions for future reference.
The generator is an engine–driven, revolving field,
alternating and direct current (AC & DC) generator. It
was designed to supply electrical power for operating
compatible electrical lighting, appliances, tools and motor
loads. The generator’s revolving field is driven at about

by a single-cylinder engine.
The outdoor generator can be used to power outdoor
items using extension cords or to restore home power
using a transfer switch. A transfer switch is a separate
device installed by a licensed electrician that allows the
portable generator to be cord connected, using the locking
receptacle, directly into your home’s electrical system.
Install a listed transfer switch as soon as possible if
generator will be used to provide home power restoration.
Every effort has been made to ensure that the information
in this manual is both accurate and current. However, the
manufacturer reserves the right to change, alter or otherwise
improve the generator and this documentation at any time
without prior notice.
NOTICE If you have questions about intended use, contact
an authorized service dealer. This equipment is designed to
be used with Briggs & Stratton® authorized parts only.

This feature is designed to greatly improve fuel economy.
, engine speed increases as
electrical loads are connected, and decreases as electrical
loads are removed.
, engine will run at full governed
speed.
NOTICE Always have the switch OFF (0) when starting or
stopping generator or when using DC USB ports.
EN3
System Ground
The generator has a system ground that connects the generator
frame components to the ground terminals on the AC output
receptacles. The system ground is connected to the AC neutral
wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal or State regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician,
electrical inspector, or
the local agency having jurisdiction.
This generator is not intended to be used at a construction
site or similar activity as defined by NFPA 70-2017 (NEC)
section 590.6.


Connections to your home’s electrical system must use a
listed* transfer switch installed by a licensed electrician.
The connection must isolate the generator power from
the utility power and comply with all applicable laws and
electrical codes. Power your home with a 30 Amp transfer
switch system.

Outlet
Transfer

Typical Indoor Items

1. Only use grounded cords marked for outdoor use
rated for your loads.

extension cords
Total
Amperage
Minimum Gauge, Outdoor Rated
Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 13A
16

Up to 15A

12
Up to 20A
12

Up to 30A

8
2. Follow cord safety instructions.
3. Install carbon monoxide alarm(s).
4. When operating generator with extension cords, make
sure it is located in an open, outdoor area, at least 20
ft. (6.1 m.) from occupied spaces with exhaust pointed
away.
5. Extension cords running directly into home, powering
indoor items IS NOT RECOMMENDED.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that will kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Extension cords running directly into the home
increase your risk of carbon monoxide poisoning
through openings.
If an extension cord running directly into the home is
used to power indoor items, the operator recognizes
that this increases the risk of CO poisoning to people
inside the home and assumes that risk.
6. Install a listed* transfer switch as soon as possible
if generator will be used to provide home power
restoration.
Equipment Description
* Certified by a Nationally Recognized Testing Laboratory
that the product complies to appropriate product safety test
standards.
120V
OUTLET
 BRIGGSandSTRATTON.COM
Equipment Description
Air Cleaner (under back cover) — Filters engine intake air.
Back Cover — Remove to gain access to the air filter.
Choke Control — Used when starting a cold engine.
Engine Identification (under side maintenance cover) —
Provides model, type and serial number of engine.
Engine Switch — Set switch to ON (I) before using recoil
starter. Set switch to OFF (0) to stop engine. Also turns fuel
valve on and off.
Fuel Cap — Add unleaded fuel here.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Handholds — Provided for convenient lifting.
Identification Label — Provides model and serial number of
generator.
Oil Drain Plug — Drain engine oil here.
Oil Fill/Dipstick (under side maintenance cover) — Check
and add engine oil here.
Recoil Starter — Used to start the engine manually.
Retractable Handle — Press button and pull handle out to
move generator. Press button to push handle back in.
Side Maintenance Cover — Remove to gain access to the
spark plug, spark arrester, and oil service.
Spark Arrester Muffler/Exhaust — Exhaust muffler lowers
engine noise and is equipped with a spark arrester screen.
Engine Identification
Oil Fill/Dipstick
Oil Drain Plug
Fuel Cap
Spark Arrester Muffler/Exhaust
Air Cleaner
Identification Label
Side Maintenance Cover
Back Cover
Handhold
Handhold
Grounding Fastener
Choke Control
Engine Switch
Recoil Starter
Retractable Handle
Handholds
EN5

120 Volt AC, 20 Amp, GFCI Duplex Receptacles — Used
to supply 120 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — Used to
supply 120 / 240 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
Circuit Breakers (AC) — The 120 Volt AC, 20A GFCI
duplex receptacles are provided with “push to reset” 20
Amp circuit breakers to protect the generator against
electrical overload.
Carbon Monoxide (CO) Shutdown Indicator Light —
Indicates the engine shutdown due to carbon monoxide
accumulation around the generator or a CO shutdown
system fault occurred.
Low Oil Indicator — This unit is equipped with a low oil
protection device. Oil must be at proper level for engine
to run. If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with dipstick.
Overload Reset — If the generator was overloaded, press
the OVERLOAD RESET button to continue in normal
operating mode. The button also activates the hour meter.
See Hour Meter.
Power Use LED’s — Measures the output wattage
(generator load) of all the generator receptacles and
displays the percentage of total generator load. LED’s will
also flash to show generator hours. See Hour Meter.

to turn the QPT switch on (I) and off (0).
Rocker Switch Circuit Breaker — The receptacles are
provided with a 2 pole rocker switch circuit breaker to
protect the generator against electrical overload.
USB Ports — Use ports to recharge most USB powered devices.
Main Breaker
120/240 Volt AC, 30 Amp
Locking Receptacle
120 Volt AC, 20 Amp
GFCI Duplex Receptacles
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and product warnings.
QPT
Switch
USB Ports
Power Use
LED’s
Carbon Monoxide
(CO) Shutdown
Indicator Light
Circuit
Breakers
Low Oil
Indicator
Overload
Reset
EN6 BRIGGSandSTRATTON.COM

Exhaust/muffler
Point away from home
Do not open air box
cover. See Service
Air Filter.
EN7
Operation
Operation

Before starting the portable generator there are two equally
important safety concerns regarding carbon monoxide
poisoning and fire that must be addressed.

Carbon Monoxide Poisoning
The engine exhaust of all fossil fuel burning equipment,
such as a portable generator, contains carbon monoxide,
a poisonous gas that will kill you in minutes. You cannot
smell it, see it, or taste it. Even if you do not smell exhaust
fumes, you could still be exposed to carbon monoxide gas.
By law in many jurisdictions it is required to have a carbon
monoxide alarm in operating condition in your home.
A carbon monoxide alarm is an electronic device that
detects hazardous levels of carbon monoxide. When there
is a buildup of carbon monoxide, the alarm will alert the
occupants by flashing visual indicator light and alarm.
Smoke alarms cannot detect carbon monoxide gas.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that wil kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Operate portable generator only outdoors, at least
20 ft. (6.1 m) from occupied spaces with exhaust
pointed away to reduce the risk of carbon monoxide
accumulating.
Install battery-operated carbon monoxide alarms or
plug-in carbon monoxide alarms with battery back-up
according to the manufacturer’s instructions. Smoke
alarms cannot detect carbon monoxide gas.
Do not run portable generator inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for
hours, even after this product has shut off
If you start to feel sick, dizzy, weak, or your homes carbon
monoxide alarm sounds while using this product, get to
fresh air right away. Call emergency services. You may
have carbon monoxide poisoning.

Install carbon monoxide alarm
inside your home. Without
working carbon monoxide
alarms, you will not realize you
are getting sick and dying from
carbon monoxide poisoning.


20 ft. (6.1 m) min.

Use outdoors at least 20 ft. (6.1 m) from any home.
Point exhaust away from all homes and occupied spaces.
Install CO alarms inside your home.
EN8 BRIGGSandSTRATTON.COM
Operation

WARNING!
Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death or serious injury.
Portable generator must be at least 5 ft. (1.5 m) from any
structure, overhang, trees, shrubs, or vegetation over 12
in. (30.5 cm) in height.
Do not place portable generator under a deck or other
type of structure that may confine airflow. Smoke alarm(s)
must be installed and maintained indoors according to the
manufacturer’s instructions/recommendations.
Carbon monoxide alarms cannot detect smoke.
Do not place portable generator in manner other than
shown.
MUFFLER
5 ft. (1.5 m)
min.
5 ft. (1.5 m)
min.
20 ft. (6.1 m) min.
EN9
Operation

Fuel must meet these requirements:
• Clean, fresh, unleaded fuel with a minimum of 87 octane.
Gasoline with an ethanol content up to 10% is acceptable.

E15
NOTICE Do not mix oil in fuel or modify engine to run on
alternate fuels. Use of unapproved fuels could damage
engine and will not be covered under warranty.
See High Altitude for 5,000 ft. and above.
WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
Do not refuel or move during operation.
Do not smoke during refueling.
Turn engine off and let it cool at least 2 minutes before
removing fuel cap.
Fill fuel tank outdoors. Keep fuel away from sparks, open
flames, pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
1. Move generator outdoors to a flat, level surface.
2. Loosen the three maintenance cover screws and
remove the side maintenance cover.
3. Clean area around oil fill and remove dipstick.
4. Using oil funnel, slowly pour oil into oil fill opening.
5. Checking oil level frequently, fill to full mark (top hole)
on dipstick.
NOTICE Pause to permit oil to settle. Wipe dipstick clean
each time oil level is checked. DO NOT overfill.
6. Replace and fully tighten dipstick.
7. Replace the maintenance cover and hand tighten the
three maintenance cover screws.
8. Slowly remove fuel cap to relieve pressure in tank.
9. Slowly add unleaded fuel to fuel tank. Be careful not
to fill above lip. This allows adequate space for fuel
expansion.
10. Install fuel cap and let any spilled fuel evaporate
before starting engine.

At altitudes over 5,000 ft. (1524 m), a minimum 85 octane
fuel is acceptable. To remain emissions compliant, high
altitude adjustment is required. Operation without this
adjustment will cause decreased performance, increased
fuel consumption,
and increased emissions.
See an authorized Briggs & Stratton dealer for high altitude
adjustment information. Operation of the engine at altitudes
below 2,500 ft. (762 m) with the high altitude kit is not
recommended.
Transporting
When transporting equipment with a vehicle or trailer,
turn engine switch to off (0) position. Do not tip engine or
equipment at an angle which causes fuel to spill.
NOTICE Do not lift or carry generator by retractable
handle. Handholds provided for convenient lifting.

The low oil indicator system is designed to prevent engine
damage caused by not enough engine oil. If the engine
oil level drops below a preset level, the red LED low oil
indicator light comes on and an oil level switch will stop the
engine. If the engine stops or the red LED low oil indicator
light comes on when you pull the recoil handle, check the
engine oil level.
Add
Full
 BRIGGSandSTRATTON.COM
Step 3: Generator Start Up
NOTICE Always have QPT switch OFF (0) when starting or
stopping generator or when using DC USB ports.
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is outdoors on a level surface.
NOTICE Failure to operate the unit on a level surface may
cause the unit to shut down.
2. Pull choke control out to close choke ( ).
3. Turn engine switch to ON (I) position.
4. Grasp recoil starter handle and pull slowly until slight
resistance is felt. Then pull rapidly once to start engine.
5. Open choke gradually as engine warms up by pushing
in on choke handle.
NOTICE If engine fails to start, push choke control in and
repeat step 4. If engine starts but fails to run, see Low Oil
Indicator in Oil and Fuel.

Using Extension Cords
Use only grounded extension cords marked for outdoor
use rated for your loads. Follow cord safety instructions.
WARNING! Damaged or overloaded extension
cords could overheat, arc, and burn resulting in
death or serious injury.

The power use monitor indicates the percentage of total
generator load using 4 LED’s. The first green LED indicates
the generator is operating normally or producing more than
25% load. The second green LED comes on after 50% load
is reached. The yellow LED comes on after 75% load is
reached. The red LED flashes when load reaches 100%.
Overload Reset
If the generator is overloaded, the red 100% load LED
illuminates and cuts power to the receptacles. You
must turn off and unplug all electrical loads. Press the
OVERLOAD RESET button on the generator control panel
and then plug in and restart electrical loads one at a time to
continue in normal operating mode.

The maximum current available for the USB ports is 2.1 Amps
at 5 Volts. The USB port allows you to recharge most USB
powered devices with a USB charging cable (not included).
NOTICE For maximum output when charging Apple
devices, use the bottom USB port.
NOTICE For charging ITE (Information Technology
Equipment) only.

Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 Watts (2.4 kW)
at 20 Amps of current.

The duplex receptacles are equipped with Ground Fault
Circuit Interrupter (GFCI) protection. The GFCI protects
against electrical shock that may be caused if your body
becomes a path which electricity travels to reach ground.
When protected by a GFCI, one may still feel a shock, but
the GFCI is intended to cut current off quickly enough so
that a person in normal health should not suffer any serious
electrical injury.
WARNING! Generator voltage could cause
electrical shock or burn resulting in death or
serious injury. Contact with the hot and neutral
conductor at the same time could cause electrical shock
or burn, even if the circuit is GFCI protected.

With the engine running, test your GFCI outlet prior to each
use, as follows:
Push the “Test” button. The “Reset” button should pop
out, which should allow no power to reach the outlet.
Press the “Reset” button firmly until it is fully in place
and locks in that position. If the GFCI outlet does
not reset properly, do not use the outlet. Call or take
your generator to a local Briggs & Stratton authorized
service dealer.
If the GFCI trips by itself at any time, reset and test the
outlet.
Operation
Power Use
LED’s
Overload
Reset
Recoil
Starter
Choke Control
Engine
Switch
USB
Ports
GFCI Duplex
Receptacles
EN11
Operation

Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps. The
generator’s locking receptacle is not protected by a GFCI.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 5,000 Watts of power (5.0kW)
at 20.8 Amps for 240 Volts or two independent 120 Volt
loads at 20.8 Amps each.
Generator Capacity
To make sure your generator can supply enough running
watts and starting watts for the items you will power at the
same time, follow these three simple steps:
1. Select the items you will power at the same time. See
following list for typical wattages.
Tool or Appliance
Running
Watts*
Starting
Watts**
Light Bulb - 75 Watt 75 -
Sump Pump - 1/3 HP 1140 2850
Refrigerator/Freezer 550 1350
Water Well Pump - 1/3 HP 575 1440
Window AC - 10,000 BTU 1000 2100
Furnace Fan Blower - 1/2 HP 800 2350
Microwave Oven - 1000 Watt 1000 -
Plasma Television - 50” 500 -
Laptop 250 -
Garage Door Opener - 1/2 HP 300 500
* Typical wattages listed are approximate only. Check tool
or appliance for actual wattage.
** The momentary electrical current the generator can
provide to start electric motors, per Briggs & Stratton
standard 628K. It does not represent the power required to
continuously run electrical loads. It is the maximum current
that can momentarily be supplied when starting a motor,
multiplied by the generator’s rated voltage.
2. Total the running watts. This is the amount of power
your generator must produce to keep your items
running. See following example:
Example
Tool or Appliance Running Watts Starting Watts
Window AC - 10000 BTU
1000 2100
Refrigerator/Freezer 550 1350
Plasma Television 500
Light (75 Watts) 75
2125 Total
Running Watts
2100 Highest
Starting Watts
Total running watts = 2125
Highest starting watts = 2100
Total generator watts required = 4225
3. Estimate the starting watts you will need. Because not
all motors start at the same time, total starting wattage
can be estimated by adding only the item with the
highest additional starting watts requirements to the
total running watts from step 2.

To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the engine
outdoors.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity.
Take special care to consider starting watts in generator
capacity.

Automatically shuts down the engine when harmful levels
of carbon monoxide accumulate around the generator or
a CO shutdown system fault occurs. After shutdown, the
indicator light will blink for at least five minutes per the
chart below.
The CO shutdown system DOES NOT replace carbon
monoxide alarms. Install battery-powered carbon monoxide
alarm(s) in your home. Do not run generator in enclosed
areas.
4-Wire Cord Set
240V
120V
W (Neutral)
X (Hot)
Y (Hot)
Ground (Green)
120V

EN12 BRIGGSandSTRATTON.COM
Maintenance
 Description
Red
• •
Carbon monoxide accumulated around
generator. Move generator to an
open, outdoor area 20 ft. (6.1 m) from
occupied spaces with exhaust pointed
away. Automatic shutoff is an indication
generator was improperly located. Air
out premises (e.g. open windows and
doors) before reoccupying.
If you start to feel sick, dizzy, weak, or
your homes carbon monoxide alarm
sounds while using this product, get to
fresh air right away. Call emergency
services. You may have carbon
monoxide poisoning.
Blue
• • •
CO shutdown system fault occured
¥
.
See Briggs & Stratton authorized service
dealer.
¥
Blue light will blink for five seconds at the startup of generator to
show the CO shutdown system is functioning properly.

1. Turn off and unplug all electrical loads from generator
panel receptacles. Never stop engine with electrical
devices plugged in and turned on.
2. Let engine run at no-load for one minute to stabilize
internal temperatures of engine and generator.
3. Turn engine switch to 0FF (0) position.
Maintenance

Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
1
Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer
for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To
receive full value from the warranty, the operator must
maintain the generator as instructed in this manual.
All service and adjustments should be made at least once
each season. A new spark plug and clean air filter assure
proper fuel-air mixture and help your engine run better and
last longer. Follow requirements in Maintenance Schedule.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual.
However, to obtain ”no charge” emissions control service,
the work must be performed by a factory authorized dealer.
See Emissions Warranty.
Hour Meter
The hour meter is integrated into the Power Use LED’s
and indicates the amount of hours the generator has
accumulated. To activate, press and hold the OVERLOAD
RESET button for 3 seconds.
The LED lights should be read from left to right.
Each LED will blink once for 2 seconds to let the user know
how many digits will display. OK represents the first digit,
25% the second digit, 75% the third digit, and 100% the
fourth digit. Each LED will blink the number of hours. Digits
with a zero will remain lit.
Example
Hours OK
First Digit
25%
Second
Digit
75%
Third Digit

Fourth
Digit
2 Hours Off Off Off Blink x 2
47 Hours Off Off Blink x 4 Blink x 7
108 Hours Off Blink x 1 On Blink x 8
1264 Hours Blink x 1 Blink x 2 Blink x 6 Blink x 4
Cleaning
Daily or before use, look around and underneath the
generator for signs of oil or fuel leaks. Clean any accumulated
debris. Keep area around muffler free from any debris.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a damp cloth to wipe exterior surfaces clean.
NOTICE Improper treatment of generator could damage
it and shorten its life. Do not expose generator to excessive
moisture, dust, dirt, or corrosive vapors. Do not insert any
objects through cooling slots.

Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 25 Hours or Yearly
Clean engine air filter
1

Inspect muffler and spark arrester

Change engine oil
1
Yearly
Replace engine air filter
1
Replace spark plug
EN13
Maintenance
Engine Maintenance
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF,
SG, SH, SJ or higher. Do not use special additives.
Outdoor temperatures determine the proper oil viscosity
for the engine. Use the chart to select the best viscosity for
the outdoor temperature range expected. Engines on most
outdoor power equipment operate well with 5W30 Synthetic
oil. For equipment operated in hot temperatures, Vanguard®
15W50 Synthetic oil provides the best protection.
* Below 40°F (4°C) the use of SAE 30 will result in hard starting.
** Above 80°F (27°C) the use of 10W30 may cause increased oil
consumption. Check oil level more frequently.

Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Loosen the three maintenance cover screws and
remove the side maintenance cover.
3. Clean area around oil fill, remove dipsitck and wipe
with clean cloth. Replace dipstick. Remove and check
oil level.
4. Verify oil is at full mark (top hole) on dipstick.
5. If needed, using oil funnel, slowly pour oil into oil fill
opening to full mark (top hole) on dipstick. Do not overfill.
NOTICE Overfilling with oil could cause the engine to not
start, or hard starting.
Do not overfill.
If over the full mark (top hole) on dipstick, drain oil to
reduce oil level to full mark on dipstick.
6. Replace and tighten dipstick.
7. Replace the side maintenance cover and hand tighten
the three maintenance cover screws.
NOTICE Do not attempt to crank or start engine before
it has been properly serviced with recommended oil. This
could result in an engine failure.
CAUTION Avoid prolonged or repeated skin contact
with used motor oil. Used motor oil has been shown
to cause skin cancer in certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change the
oil more often.
Change oil while engine is still warm from running, as follows:
1. Make sure unit is on a level surface.
2. Remove oil drain plug and drain oil completely into a
suitable container.
3. Reinstall oil drain plug and tighten securely.
4. Loosen the three maintenance cover screws and
remove the side maintenance cover.
5. Clean area around oil fill, remove dipsitck and wipe
with clean cloth.
6. Slowly pour recommended oil (about 36 oz. (1.0 l))
into oil fill opening. Pause to permit oil to settle. Fill to
full mark (top hole) on dipstick.
7. Wipe dipstick clean each time oil level is checked. Do
not overfill.
8. Reinstall dipstick.
9. Wipe up any spilled oil.
10. Replace the side maintenance cover and hand tighten
the three maintenance cover screws.
Oil Drain
Plug
Add
Full
 BRIGGSandSTRATTON.COM
Maintenance

WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
Do not start and run engine with air filter removed.
Your engine will not run properly and may be damaged if
you run it with a dirty air cleaner. Clean or replace more
often if operating under dusty or dirty conditions.

1. Loosen back cover screws, slide cover up and remove.
2. Carefully remove foam filter by pulling it out towards you.
3. Wash foam filter in liquid detergent and water only.
Squeeze dry in a clean cloth.
4. SATURATE foam air filter in clean engine oil and
squeeze in a clean cloth to remove excess oil.
5. Reinstall clean or new foam filter inside base behind
face plate.
NOTICE Be sure filter is fully seated behind the face plate.
6. Slide back cover into grove and reinstall.

Changing the spark plug will help your engine to start
easier and run better.
1. Loosen the three maintenance cover screws and
remove the side maintenance cover.
2. Clean area around spark plug and remove spark plug boot.
3. Remove spark plug and inspect spark plug.
4. Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. Use the recommended
replacement plug. See Common Service Parts.
5. Check electrode gap with wire feeler gauge and reset
spark plug gap to recommended gap if necessary.
See Specifications.
6. Install spark plug and tighten firmly. Reinstall spark
plug boot.
7. Replace the side maintenance cover and hand tighten
the three maintenance cover screws.

The engine exhaust muffler has a spark arrester screen.
Inspect the muffler for cracks, corrosion, or other damage.
Inspect spark arrester screen for damage or carbon
blockage. Clean if carbon blockage is found or replace if
damaged. If replacement parts are required, make sure to
use only original equipment replacement parts.
WARNING!
Contact with muffler area could
cause burns resulting in serious injury.
Do not touch hot parts.
It is a violation of California Public Resource Code, Section
4442, to use or operate the engine on any forest-covered,
brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined
in Section 4442, maintained in effective working order.
Other states or federal jurisdictions may have similar laws,
reference Federal Regulation 36 CFR Part 261.52.

1. Loosen the three maintenance cover screws and
remove the side maintenance cover.
2. Remove screw that attaches spark arrester screen to
muffler. Remove spark arrester screen.
3. Obtain a replacement screen. See Common Service
Parts.
Screw
Spark
Arrester
Filter
Face Plate
EN15
Storage
4. Reattach screen to muffler. Reattach side cover.
Common Service Parts
Air Cleaner .............................596106
Spark Plug .............................798615
Engine Oil Bottle ...............100005 or 100028
Synthetic Oil Bottle ......................100074
Contact an authorized service dealer or
BRIGGSandSTRATTON.COM for a full list of parts and
diagrams.
Storage
If storing the unit for more than 30 days, use the following
guidelines to prepare it for storage.

1. Clean the generator as outlined in Cleaning.
2. Change engine oil while engine is still warm, drain oil
from crankcase. Refill with recommended grade. See
Changing Engine Oil.
3. Treat or drain fuel from generator as fuel can become
stale when stored over 30 days.
Each time you fill the container with fuel, add STA-BIL
360°® PROTECTION™ to the fuel as specified by the
manufacturer’s instructions. This keeps fuel fresh and
decreases fuel-related problems or contamination in the
fuel system.
It is not necessary to drain fuel from the engine when STA-
BIL 360°® PROTECTION™ is added as instructed. Before
storage, turn the engine ON for 2 minutes to move the fuel
and stabilizer through the fuel system.
If fuel in the engine has not been treated with STA-
BIL 360°® PROTECTION™, it must be drained into an
approved container. Then run the engine until it stops from
lack of fuel.
WARNING!
Fuel and its vapors are extremely
flammable and explosive which could cause
burns, fire or explosion resulting in death or
serious injury.
When storing fuel or equipment with fuel in tank, store
away from furnaces, stoves, water heaters, clothes dryers
or other appliances that have pilot light or other ignition
source because they could ignite fuel vapors.
When draining fuel, turn generator engine off and let it
cool at least 2 minutes before removing fuel cap. Loosen
cap slowly to relieve pressure in tank. Drain fuel tank
outdoors. Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
4. Store generator in clean, dry area and cover with a
suitable protective cover that does not retain moisture.
WARNING! Storage covers could cause a fire
resulting in death or serious injury.
Do not place a storage cover over a hot generator. Let
equipment cool for a sufficient time before placing the
cover on the equipment.


Pursuant to part 15.21 of the FCC Rules, you are cautioned
that changes or modifications to transceiver not expressly
approved by Briggs & Stratton could void your authority to
operate the portable generator.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
IC Information to User
This device complies with Industry Canada’s licence-
exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including
interference that may cause undesired operation of device.
This spark ignition system complies with the Canadian
standard CAN ICES-2/NMB-2.
EN16 BRIGGSandSTRATTON.COM

Specifications
Running Watts* ...........................5,000
Starting Watts** ...........................6,500
AC Current at 240 Volts ............... 20.8 Amps
AC Current at 120 Volts ............... 41.6 Amps
Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hz
Phase ............................ Single Phase
Displacement ................18.67 cu. in. (306 cc)
Spark Plug Gap ...............0.030 in. (0.76 mm)
Fuel Capacity ...........5 U.S. Gallons (18.9 Liters)
Oil Capacity ................36 Ounces (1.0 Liters)
Problem Cause Correction
Engine is running, but no AC
output is available.
1. Red LED light is steady. Generator is
overloaded or overheated.
2. Poor connection or defective cord set.
3. Connected device is bad.
1. See Generator Capacity. Press
OVERLOAD RESET button on
control panel.
2. Check and repair.
3. Connect another device that is in
good condition.


connected.
1. Generator is overloaded. 1. See Generator Capacity.



1. Engine switch in OFF (0) position.
2. Low oil indicator light comes on. Low
oil level.
3. Dirty air filter.
4. Out of fuel.
5. Spark plug wire not connected to
spark plug.
6. Flooded with fuel.
1. Turn engine switch to ON (I) position.
2. Fill crankcase to proper level or place
generator on level surface.
3. Clean or replace air filter.
4. Fill fuel tank.
5. Connect wire to spark plug.
6. Wait 5 minutes and re-crank engine.



1. Generator improperly located.
1. Move generator to an open,
outdoor area. Air out premises (e.g.
open windows and doors) before
reoccupying. See Carbon Monoxide
(CO) Shutdown System.

The gross power rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive
Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are
derived at 2600 RPM for those engines with “rpm” called out on the label and 3060 RPM for all others; horsepower values are derived
at 3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust
and air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher
than net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the
wide array of products on which engines are placed, the gasoline engine may not develop the rated gross power when used in a given
piece of power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components
(air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature,
humidity, altitude), and engine-to engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an
engine of higher rated power for this engine.
*Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, Motors and Generators
and PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018, Safety and Performance of Portable
Generators.
**Per Briggs & Stratton 628K
EN17

DC WINDING
MAIN WINDING 1
LOW VOLTAGE POWER WINDING
IGITION POWER
WINDING
RECTIFYING
BRIDGE
STEPPING MOTOR
RED OVERLOAD LED
YELLOW RUN LED (75% LOAD)
SPARK
PLUG
BLUE
BLUE
RED
RED
YELLOW
BLUE
PINK
ORANGE
RED
MAIN WINDING I
MAIN WINDING II
IGNITION POWER WINDING
THREE PHASE AC
INPUT END "A"
7-.('
RED
BLU
BLK
(COMM)
MAIN WINDING 2
CONTROL MODULE
ENGINE IGNTION
MODULE
GREEN RUN LED (50% LOAD)
GREEN RUN LED (25% LOAD)
RED LOW OIL LED
PINKPINK
FERRITE BEAD
A
A
VIEW A-A
18
27
36
45
CO
MODULE
RED LED
BLUE LED
200Ω
REMOTE LED
ENGINE
GROUND
IGITION POWER WINDING
IGITION POWER WINDING (RED)
GND (GREEN/YELLOW)
IGITION POWER WINDING
IGITION POWER WINDING
THREE PHASE AC INPUT END "B"
LOW-VOLTAGE POWER WINDING OF INVERTER
120V
LOW-OIL ASSEMBLY SENSOR
120V
BLACK
LED LIGHT BARS
USB
5V/2A
5V REGULATOR
REMOTE LED
BLACK
RED
BLUE
1 2345
CO MODULE
EN18 BRIGGSandSTRATTON.COM
Warranty
80011053_EN Rev. A


Briggs & Stratton warrants that, during the warranty period specified below, it will repair or replace, free of charge, any part that is defective in material or workmanship
or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for
and is subject to the time periods and conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTATTON.COM. The purchaser must contact the Authorized Service Dealer, and then make the product available to the Authorized Service Dealer for
inspection and testing.
 
. 
Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state or country to country.**
WARRANTY PERIOD
After 12 months, warranty covers parts only.
* Applies to Briggs & Stratton engines only. Warranty coverage of non-Briggs & Stratton engines is provided by that engine manufacturer. Emissions-related components
are covered by the Emissions Warranty Statement.
** In Australia - Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTRATTON.COM, or by calling 1300 274 447, or by emailing or writing to [email protected], Briggs & Stratton Australia Pty Ltd, 1
Moorebank Avenue, NSW, Australia, 2170.
The warranty period begins on the date of purchase by the first retail or commercial consumer. “Consumer use” means personal residential household use by a retail
consumer. “Commercial use” means all other uses, including use for commercial, income producing or rental purposes. Once a product has experienced commercial
use, it shall thereafter be considered as a commercial use product for purposes of this warranty.
Save your proof of purchase receipt. If you do not provide proof of the initial purchase date at the time warranty service is requested, the manufacturing date of the
product will be used to determine the warranty period. Product registration is not required to obtain warranty service on Briggs & Stratton products.
ABOUT YOUR WARRANTY
Warranty service is available only through Briggs & Stratton Authorized Service Dealers. This warranty covers only defects in materials or workmanship. It does not cover
damage caused by improper use or abuse, improper maintenance or repair, normal wear and tear, or stale or unapproved fuel.
Improper Use and Abuse - The proper, intended use of this product is described in the Operator’s Manual. Using the product in a way not described in the Operator’s
Manual or using the product after it has been damaged will not be covered under this warranty. Warranty coverage will also not be provided if the serial number on the
product has been removed or the product has been altered or modified in any way, or if the product has evidence of abuse such as impact damage or water/chemical
corrosion damage.
Improper Maintenance or Repair - This product must be maintained according to the procedures and schedules provided in the Operator’s Manual, and serviced or
repaired using genuine Briggs & Stratton parts or equivalent. Damage caused by lack of maintenance or use of non-original parts is not covered by warranty.
Normal Wear and Tear - Like most mechanical devices, your unit is subject to wear even when properly maintained. This warranty does not cover repairs when normal
use has exhausted the life of a part or the equipment. Maintenance and wear items such as filters, belts, cutting blades, and brake pads (except engine brake pads) are
not covered by warranty due to wear characteristics alone, unless the cause is due to defects in material or workmanship.
- In order to function correctly, this product requires fresh fuel that conforms to the criteria specified in the Operator’s Manual. Engine or
equipment damage caused by stale fuel or the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty.
This warranty excludes damage due to accident, abuse, modifications, alterations, improper servicing, freezing or chemical deterioration.
Attachments or accessories that were not originally packaged with the product are also excluded. There is no warranty coverage on equipment used for primary power in
place of utility power or on equipment used in life support applications. This warranty does not include used, reconditioned, second-hand, or demonstration equipment or
engines. This warranty also excludes failures due to acts of God and other force majeure events beyond the manufacturer’s control.
Item Consumer Use Commercial Use
Equipment 24 months 12 months
Engine* 24 months 12 months
Battery (if equipped) 3 months None
Génératrice à inverseur pour
usage à l’extérieur
Manuel d’utilisation
Numéro de modèle __________________________
Révision __________________________________
Numéro de série ____________________________
Date d’achat _______________________________
Copyright © 2019. Briggs & Stratton Corporation
Milwaukee, WI, États-Unis. Tous droits réservés.
800 743-4115
BRIGGSandSTRATTON.COM
 BRIGGSandSTRATTON.COM
Description de l’équipement
Table des matières
Description de l’équipement ....................2
Fonctions et commandes.......................5
Utilisation....................................7
Entretien ...................................13
Entreposage ................................17
Déclaration de conformité FCC/IC
................17
Dépannage/Caractéristiques techniques .........18
Garantie....................................22
Enregistrer votre produit
Pour garantir que la garantie s’applique complètement et
dans les meilleurs délais, enregistrez votre produit en ligne
au www.onlineproductregistration.com.
Symboles et significations
Signal Signification
DANGER
Indique un risque qui, s’il n’est pas évité,
causera la mort ou des blessures graves.

Indique un danger lequel, si non évité, peut
entraîner la mort ou des blessures graves.
ATTENTION
Indique un risque qui, s’il n’est pas
évité, pourrait causer des blessures
mineures ou modérées.
AVIS
Indique de l’information considérée
comme importante mais n’impliquant
aucun danger particulier.
Symbole Nom Explication
Symbole
d’alerte de
sécurité
Indique un risque de blessure
corporelle possible.
Manuel
d’utilisation
Ne pas respecter les avertissements,
les instructions et le manuel de
l’utilisateur peut entraîner des
blessures graves ou la mort.
Vapeurs
toxiques
Les gaz d’échappement du moteur
contiennent du monoxyde de
carbone, un gaz toxique qui vous
tuera en quelques minutes. Il est
incolore et inodore.
Incendie
Le gaz propane et le gaz naturel
sont extrêmement inflammables et
explosifs et pourraient causer des
brûlures ou un incendie susceptibles
d’entraîner des blessures graves,
voire la mort.
L’échappement du moteur peut
entraîner un incendie, ce qui peut
provoquer des blessures graves,
voire la mort.
Symbole Nom Explication
Électrocution
La génératrice peut provoquer une
électrocution entraînant la mort ou de
graves lésions.
Surface
chaude
Le silencieux peut causer des
brûlures risquant de provoquer des
blessures graves.
Ce produit peut vous exposer à
des agents chimiques, y compris les échappements
des moteurs à essence, connus dans l’État de la
Californie pour causer le cancer, ainsi que le monoxyde de
carbone, connu dans l’État de la Californie pour causer des
malformations congénitales ou les dommages à l’appareil
reproducteur. Pour obtenir de plus amples renseignements,
visitez le www.P65Warnings.ca.gov.
Description de l’équipement
Lisez bien ce manuel et familiarisez-vous avec
votre génératrice extérieure. Apprenez ses
applications, ses limitations ainsi que tous les
risques impliqués. Conservez ces instructions pour toute
consultation ultérieure.
La génératrice est entraînée par moteur, à champ tournant,
produisant du courant alternatif et du courant continu (C.A. et
C.C.). Elle a été conçue pour alimenter les circuits d’éclairage
compatibles, les appareils électroménagers, les outils et les
moteurs. Le champ tournant de la génératrice qui tourne à


Le générateur
extérieure
peut être utilisé pour alimenter
des objets d’extérieur à l’aide de rallonges ou pour rétablir
l’alimentation domestique à l’aide d’un commutateur de
transfert. Un commutateur de transfert est un appareil
séparé installé par un électricien certifié qui permet de relier
le générateur portable par cordon, à l’aide de la prise de
courant verrouillable, directement dans le système électrique
domestique. Installez un commutateur de transfert listé
dès que possible si le générateur sera utilisé pour rétablir
l’alimentation domestique.
Nous nous sommes efforcés de fournir dans ce document des
informations exactes et à jour. Toutefois, le fabricant se réserve le
droit de changer, de modifier ou encore d’améliorer la génératrice
et cette documentation en tout temps, et ce, sans préavis.
AVIS Si vous avez des questions sur l’usage prévu, demandez
à votre concessionnaire ou prenez contact avec un agent d’un
service après-vente agréé. Cet équipement est conçu pour être
utilisé uniquement avec les pièces Briggs & Stratton® approuvées.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Simplicity 030766-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues