Fadini elpro-s50-T1 Instructions Manual

Taper
Instructions Manual
Elpro S50-T1
- PREDISPOSTO PER SEMAFORO A 3 LUCI
- AUTOMATICO O SEMIAUTOMATICO
- PREDISPOSIZIONE PER OROLOGIO ESTERNO
- FUNZIONE PASSO-PASSO
- UOMO PRESENTE
- PRE-SET FOR A TRAFFIC LIGHT WITH 3 LAMPS
- AUTOMATIC OR SEMI-AUTOMATIC
- PRE-SET FOR EXTERNAL TIME CLOCK
- STEP BY STEP FUNCTION
- DEADMAN (HOLD-ON-SWITCHED) CONTROL
- PREPARE POUR FEU DE CIRCULATION A 3 VOYANTS
- AUTOMATIQUE OU SEMI-AUTOMATIQUE
- PREPARE POUR HORLOGE EXTERNE
- FONCTION PAS-PAS
- HOMME MORT
- FÜR AMPEL MIT 3 LICHTERN VORGESEHEN
- AUTOMATISCH ODER HALBAUTOMATISCH
- FÜR EXTERNE UHR VORGESEHEN
- SCHRITT FÜR SCHRITT FUNKTION (IMPULSBETRIEB)
- TOTMANN-BETRIEB
PROGRAMMATORE ELETTRONICO MONOFASE
PER UN DISSUASORE A SCOMPARSA ANTITERRORISMO TALOS M50
SINGLE-PHASE ELECTRONIC CONTROLLER
FOR ONE TALOS M50 ANTI-TERRORISM RETRACTABLE BOLLARDS
PROGRAMMATEUR ÉLECTRONQUE MONOPHASÉ
POUR UNE BORNE ESCAMOTABLE ANTI-TERRORISME TALOS M50
EINPHASIGE ELEKTRONISCHE STEUERUNG
FÜR EINEN TALOS M50 ANTI-TERROR VERSENKBARE POLLER
IT
GB
FR
DE
IT
GB
FR
DE
Dis. N. 7751 Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422 Fax +39 0442 331054
[email protected] - www.fadini.net
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50
Elpro S50-T1
IT
AVVERTENZE GENERALI PER LA SICUREZZA DELLE PERSONE
GRAZIE
Vi ringraziamo per aver deciso di acquistare un prodotto Fadini.
Vi invitiamo a leggere attentamente queste istruzioni prima di
iniziare a usare il dispositivo. Le istruzioni contengono
informazioni importanti che vi aiuteranno a trarre il meglio da
questo dispositivo e vi garantiranno altresì sicurezza in fase di
installazione, uso e manutenzione del dispositivo. Conservare
questo manuale in un luogo pratico, in modo da poterlo
sempre consultare e garantire un utilizzo sicuro e adeguato del
dispositivo.
INTRODUZIONE
Questa automazione è stata progettata per un utilizzo
esclusivo per quanto indicato in questo libretto, con gli
accessori di sicurezza e di segnalazione minimi richiesti e con i
dispositivi Fadini. Qualsiasi altra applicazione non
espressamente indicata in questo libretto potrebbe provocare
disservizi o danni a cose e persone. Meccanica Fadini S.r.l. non
è responsabile per eventuali danni derivati da usi impropri e
non specicatamente indicati in questo libretto; non risponde
inoltre di malfunzionamenti derivati dall'uso di materiali e/o
accessori non indicati dalla ditta stessa. La ditta costruttrice si
riserva di apportare modiche ai propri prodotti senza
preavviso. Tutto quanto non espressamente indicato
inquesto manuale di istruzioni non è permesso.
PRIMA DELL'INSTALLAZIONE
Prima di qualsiasi intervento valutare l'idoneità dell'ingresso da
automatizzare, nonché la sua condizione e la struttura.
Accertarsi che non si verichino situazioni di impatto,
schiacciamento, cesoiamento, convogliamento, taglio,
uncinamento e sollevamento, tali da poter pregiudicare la
sicurezza delle persone. Non installare il prodotto nelle
vicinanze di fonti di calore ed evitare il contatto con sostanze
inammabili. Tenere lontano dalla portata di bambini
qualsiasi dispositivo (trasmettitori, lettori di prossimità,
selettori, ecc.) atto ad avviare l'automazione. Il transito nella
zona di luce di passaggio deve avvenire unicamente con
l'automazione ferma. Non consentire a bambini e/o persone
di stazionare nei pressi dell'impianto con l'automazione in
movimento. Per garantire un livello adeguato di sicurezza
dell'impianto è necessario utilizzare fotocellule, bordi sensibili,
spire magnetiche e sensori di presenza per mettere in sicurezza
l'intera area interessata al movimento del cancello. Servirsi di
strisce giallo-nere o di adeguati segnali per identicare i punti
pericolosi dell'installazione. Togliere sempre l'alimentazione
elettrica all'impianto se si eettuano interventi di
manutenzione e/o pulizia. In caso di asportazione
dell’attuatore, non tagliare i li elettrici, ma toglierli dalla
morsettiera allentando le viti di serraggio dentro la scatola di
derivazione.
INSTALLAZIONE
L'intera installazione deve essere eettuata da personale
tecnico qualicato, in osservanza della Direttiva Macchine
2006/42/CE e in particolare le norme EN 12445 ed EN 12453.
Vericare la presenza, a monte dell'impianto, di un interruttore
di linea 230 V - 50 Hz magneto-termico dierenziale da 0,03 A.
Utilizzare corpi di prova idonei per le prove di funzionamento
nella rilevazione della presenza, in prossimità o interposti, ai
dispositivi di sicurezza come fotocellule, bordi sensibili, ecc.
Eseguire una attenta analisi dei rischi, utilizzando appositi
strumenti di rilevazione di impatto e schiacciamento del bordo
principale di apertura e chiusura, secondo quanto indicato
nella normativa EN 12445. Individuare la soluzione più
indicata per eliminare o ridurre tali rischi. Nel caso in cui il
cancello da automatizzare fosse dotato di un ingresso
pedonale, è opportuno predisporre l'impianto in maniera tale
da interdire il funzionamento del motore quando l'ingresso
pedonale è utilizzato. Fornire indicazioni sulla presenza
dell'impianto realizzato con l'applicazione di targhe
segnaletiche con marcatura CE sul cancello. L'installatore è
tenuto ad informare ed istruire l'utilizzatore nale circa l'uso
corretto dell'impianto; ciò avviene rilasciandogli una
documentazione rmata denita fascicolo tecnico,
comprensiva di: schema e componenti dell'impianto, analisi
dei rischi, verica degli accessori di sicurezza, verica delle
forze di impatto e segnalazione dei rischi residui.
INDICAZIONI PER L'UTILIZZATORE FINALE
L'utilizzatore nale è tenuto a prendere visione e ricevere
informazioni unicamente per quanto concerne il
funzionamento dell'impianto e diviene lui stesso responsabile
del corretto uso. Deve stipulare un contratto di
manutenzione ordinaria e straordinaria (su chiamata) con
l'installatore/manutentore. Qualsiasi intervento di
riparazione deve essere eettuato solo da personale tecnico
qualicato. Conservare sempre il presente manuale di
istruzioni.
AVVERTENZE PER IL BUON FUNZIONAMENTO
DELL'IMPIANTO
Per una resa ottimale dellimpianto nel tempo e secondo le
normative di sicurezza, è necessario eseguire una corretta
manutenzione e un adeguato monitoraggio dell’intera
installazione per l’automazione, per le apparecchiature
elettroniche installate e anche per i cablaggi ad esse eettuate.
Tutta l’installazione deve essere eseguita da personale
tecnico qualicato, compilando il documento di verica e
collaudo ed il registro di manutenzione indicato nel libretto
normative di sicurezza (da richiedere o scaricare dal sito
www.fadini.net/supporto/downloads). Per l'automazione è
consigliato un controllo di manutenzione almeno ogni 6 mesi,
mentre per apparecchiature elettroniche e sistemi di sicurezza
un controllo mensile di manutenzione. Meccanica Fadini S.r.l.
non è responsabile dell'eventuale inosservanza della buona
tecnica di installazione e/o del non corretto mantenimento
dell'impianto.
SMALTIMENTO DEI MATERIALI
Gli involucri dell’imballo come cartone, nylon, polistirolo, ecc.
possono essere smaltiti eettuando la raccolta dierenziata
(previa verica delle normative vigenti nel luogo
dell'installazione in materia di smaltimento riuti). Elementi
elettrici, elettronici e batterie possono contenere sostanze
inquinanti: rimuovere e adare tali componenti a ditte
specializzate nel recupero dei riuti, come indicato nella
direttiva 2012/19/UE. Vietato gettare nei riuti materiali nocivi
per l’ambiente.
Meccanica Fadini S.r.l.
Direttore Responsabile
DICHIARAZIONE DI CONFORMITÀ UE
Fabbricante: Meccanica Fadini S.r.l.
Indirizzo: Via Mantova, 177/A - 37053 Cerea - VR - Italy
dichiara sotto la propria responsabilità che:
Programmatore elettronico ELPRO S50-T1
è conforme alla pertinente normativa di armonizzazione dell’Unione:
- Direttiva Compatibilità Elettromagnetica 2014/30/UE
- Direttiva Bassa Tensione 2014/35/UE
Cerea, 13/10/2017
2
24 25
57 58
55 56
12345678910
Attenzione: ogni volta che viene ripristinata l’alimentazione all’Elpro S50-T1, si devono attendere 10 secondi perchè la logica del programmatore torni a funzionare
regolarmente.
IMPORTANTE:
- Il programmatore deve essere installato in un luogo protetto e asciutto.
- Applicare un interruttore magneto-termico dierenziale del tipo 0,03 A ad alta sensibilità all’alimentazione del programmatore.
- Utilizzare un cavo multipolare tipo BUT FLESSIBILE FG 70R 12x1,5 mm², no ad una distanza massima di 20 m tra TALOS M50 e ELPRO S50-T1.
- Per distanze superiori a 20 metri utilizzare li di sezione idonea alla buona regola di installazione.
- Per gli accessori di comando e sicurezza utilizzare cavi da 1 mm².
N.B: per applicazioni quali accensione luci, telecamere, ecc. utilizzare relè statici per non creare disturbi al microprocessore.
ELPRO S20
T2
TEMPO DI PAUSA
1 s - 180 s
T1
TEMPO DI LAVORO
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9 L10 L11L5
ON
OFF
14567823 9101112
INNESTO PER SEMAFORO
A 3 LAMPADE MAX 100 W
PER LAMPADA
USCITA 24 Vdc
DIP-SWITCH
Elpro S20
Ingresso P
NON USARE
(pedonale)
Fotocellule
Uscita 24 V - 250 mA per carico max:
- n° 2 coppie di fotocellule
- n° 1 radio ricevente
COMUNE
APRE
CHIUDE
BLOCCO
RADIO
SPIA 24 V - 3 W max
Fusibile
Secondario
Trasformatore
F4 = 2 A
Fusibile elettrovalvola, cicalino,
lampeggiatore e led F5 = 2 A
Fusibile motore M2
F2 = 1 A
Fusibile motore M1
F1 = 1 A
SUPPORTO PER
SCHEDA RADIO
AD INNESTO
Fusibile
primario
trasformatore
F3 = 630 mA
20 VA - 50/60 Hz
TRASFORMATORE
Filtro antidisturbi
+-
51 52 53
-
+
-
+
MOTORE 1
dissuasore
CICALINO
LED DI SEGNALAZIONE
230 V - 100 W max
ALIMENTAZIONE
QUADRO 230 V ± 10%
50 Hz MONOFASE
COMUNE
FN
55 56
16
17 18 51 52 53
55 56
70 71 72 51 52 53
COMUNE
M1
necorsa +24 Vdc
li marroni cavi blu e grigio
necorsa massa
li verdi cavi blu e grigio
+-
11 12
11 12
11 12
necorsa apertura TALOS 1
cavo grigio - lo bianco
necorsa chiusura TALOS 1
cavo blu - lo bianco
F=20 A
24 25 Condensatore
con disgiuntore
elettronico
di spunto
M1 40 μF
71
72
70
nero
Condensatore
Motore 1
40 μF
72
71
Condensatore
Motore 1
40 μF
72
71
Teleruttore
DISCESA
M1
Teleruttore
SALITA
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1 24
25
24
25
32
33
31
31
70
71
72
70
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50
Elpro S50-T1
IT
3
Accessorio Collegamenti elettrici Dip-switch e segnalazione LED delle varie funzioni
NEL CASO DI MANCATO FUNZIONAMENTO
- Accertarsi che l’alimentazione al programmatore elettronico sia 230 V ± 10% - 50 Hz
- Accertarsi che l’alimentazione al motore elettrico sia 230 V ± 10% - 50 Hz
- Per distanze superiori ai 20 metri aumentare la sezione dei li
- Controllare la tensione di alimentazione 230 V monofase
- Controllare i fusibili
- Controllare tutti i contatti chiusi del programmatore
- Controllare che non ci sia una caduta di tensione tra programmatore e motore elettrico
LED DI DIAGNOSTICA
L1 = Apre pedonale, normalmente SPENTO, non usare
L2 = Fotocellule, normalmente ACCESO, si spegne con ostacolo presente
L3 = Apre, normalmente SPENTO, si illumina ad impulso apre
L4 = Chiude, normalmente SPENTO, si illumina ad impulso chiude
L5 = Blocco, normalmente ACCESO, si spegne ad impulso di blocco
L6 = Radio, normalmente SPENTO, si illumina ad impulso radio
L7 = Normalmente ACCESO, tensione di rete e integrità fusibili F1, F2, F3, F4
L8 = Finecorsa apertura M1, normalmente ACCESO, spento a colonna abbassata
L9 = Finecorsa chiusura M1, normalmente ACCESO, spento a colonna alzata
L10 = Non attivo
L11 = Non attivo
L12 = Non attivo
L13 = Non attivo
L14 = Non attivo
L15 = Non attivo
DIP-SWITCH
1 = ON Fotocellula ferma in apertura
2 = ON Radio non inverte in apertura
3 = ON Chiude in automatico
4 = ON Prelampeggio lampeggiatore attivo
5 = ON Radio passo-passo con blocco intermedio
6 = non usare
7 = ON Servizio a uomo presente
8 = Gestione semaforo (vedere riquadro delle funzioni)
9 = Gestione semaforo (vedere riquadro delle funzioni)
10 = ON Lampeggiatore spento in pausa
11 = ON Richiude in pausa dopo passaggio fotocellule
12 = ON Tempo di lavoro massimo 90 s. OFF = 18 s
Simbologia
Contatto NA
Contatto NC
Led acceso
Led spento
Spia o lampada
Lampeggiatore
ON
OFF
14567823 9101112
DIP-SWITCH
Fotocellule:
Selettore a chiave:
Contatto radio:
1
DIP-SWITCH N° 1:
ON: Fotocellula ferma in apertura ed inverte
in chiusura a ostacolo rimosso
OFF: Fotocellula non ferma in apertura ed inverte
in chiusura in presenza di ostacolo
2
DIP-SWITCH N° 2:
ON: Non inverte in apertura
OFF: Inverte la marcia ad ogni impulso
5
DIP-SWITCH N° 5:
ON: Passo passo con blocco intermedio
OFF: Funzionamento normale
11
DIP-SWITCH N° 11:
ON: Durante la pausa in automatico
(Dip-Switch 3 = ON) al passaggio davanti le
fotocellule chiude dopo 5 s
OFF: Non chiude al passaggio davanti le fotocellule
NC
COMUNE
COMUNE
APRE
CHIUDE
STOP
12
NC
910
Fotocellule
Uscita 24 V - 250 mA per carico max:
- n° 2 coppie di fotocellule
- n° 1 radio ricevente
Collegando un qualsiasi contatto NA tra i due
morsetti si può ottenere ad ogni impulso:
- Solo apertura: Dip 2 = ON e Dip 5 = OFF
- Inversione di marcia ad ogni impulso
Dip 2 = OFF e Dip 5 = OFF
- Passo passo: apre - stop - chiude - stop
Dip 2 = OFF e Dip 5 = ON
- In fase di apertura non accetta nessun
comando. In pausa e in chiusura ad ogni
comando esegue lo stop con inversione di
marcia: Dip 2 = ON e Dip 5 = ON
Contatti NA e NC da collegare ai rispettivi
morsetti dei selettori o pulsantiere.
Tutte le possibili congurazioni sono allegate
ai rispettivi accessori di comando.
3456
NC
CONTATTO RADIO
3 7
L3 spento = nessun contatto apre, si accende ad
ogni impulso di apertura
L4 spento = nessun contatto chiude, si accende
ad ogni impulso di chiusura
L5 acceso = contatto di stop chiuso, si spegne ad
ogni impulso di stop
L2 acceso = nessun ostacolo presente, si spegne
ad ostacolo presente
L7 spento = nessun contatto RADIO, si accende
ad ogni impulso del contatto radio
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50
Elpro S50-T1
IT
4
11 12 55 56
COMUNE
51 52 53 4
DIP-SWITCH N° 4:
ON: Prelampeggio
OFF: Senza prelampeggio
10
DIP-SWITCH N° 10:
ON: Lampeggio disattivato durante la pausa
in automatico
OFF: Lampeggio attivato durante la pausa
in automatico
Lampeggiatore
esterno: È possibile collegare oltre ai led integrati nel
dissuasore anche un lampeggiatore esterno.
Questo funzionerà durante il movimento di
salita e discesa e durante la pausa (se
impostata).
230 V - 100 W max
12
DIP-SWITCH N° 12:
ON: Tempo di lavoro massimo 90 s
OFF: Tempo di lavoro massimo 18 s
Spia accesa = colonna abbassata, passaggio libero
Spia spenta = colonna alzata, passaggio chiuso
Lampeggia a 0,5 s (veloce) = movimento di salita
Lampeggia a 1 s (normale) = movimento di discesa
Con orologio esterno: 2 brevi lampeggi seguiti da una pausa più lunga
Uscita per una eventuale utenza a 24 Vdc
COMUNE
3 8
Accessorio Collegamenti elettrici Dip-switch e segnalazione LED delle varie funzioni
Spia 24 V - 3 W max
di segnalazione
del movimento:
Uscita 24 Vdc:
Motori:
Finecorsa:
+-
T2
TEMPO DI PAUSA
1 s - 180 s
T1
TEMPO DI LAVORO
1 s - 22 s
-
+
-
+
55 56
Led di segnalazione:
Uscita per led a luce intermittente sempre
funzionanti durante il movimento di salita e
discesa e nella sosta a colonna alzata.
Si spengono a colonna abbassata.
L8 acceso = si spegne a colonna 1 abbassata
L9 acceso = si spegne a colonna 1 alzata
MOTORE 1
dissuasore 1
16 17 18
M1
COMUNE
200 mA per accessori
COMUNE LED
E/O CICALINO
LED
51 52 53
L10 acceso = si spegne a colonna 2 abbassata
L11 acceso = si spegne a colonna 2 alzata
necorsa apertura TALOS 1
cavo grigio - lo bianco
necorsa chiusura TALOS 1
cavo blu - lo bianco
necorsa +24 Vdc
li marroni cavi blu e grigio
necorsa massa
li verdi cavi blu e grigio
L12 acceso = si spegne a colonna 3 abbassata
L13 acceso = si spegne a colonna 3 alzata
Importante: se il dissuasore non è in fase con i
comandi apre/chiude, invertire 17/18.
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50
Elpro S50-T1
IT
5
3
DIP-SWITCH N° 3:
ON: Chiude in automatico
OFF: Non chiude in automatico.
Funzione semiautomatico
T2
TEMPO DI PAUSA
1 s - 180 s
-
+
Accessorio Collegamenti elettrici Dip-switch e segnalazione LED delle varie funzioni
FUNZIONI
Il dispositivo sonoro è all’interno della
colonna a scomparsa e attivo solo durante il
movimento di salita e discesa.
Cicalino di movimento:
Alimentazione quadro:
Descrizione Dip-switch e segnalazione LED delle varie funzioni
7
DIP-SWITCH N° 7:
ON: Funzionamento a uomo presente
OFF: Funzionamento normale
Alimentazione scheda
programmatore e quadro
Elpro S50-T1
Uomo presente:
Si ottiene il comando di apertura e chiusura “ad azione mantenuta”
(senza autotenuta nei relè). È richiesta l’attiva presenza dell’operatore
durante tutto il movimento dell’automazione no al rilascio del pulsante
o della chiave del selettore.
Automatico / semiautomatico:
Ciclo automatico: ad un impulso di comando apre, la colonna si abbassa, si ferma in pausa per il tempo
impostato sul trimmer T2, scaduto il quale risale automaticamente.
Ciclo semiautomatico: ad un impulso di comando apre la colonna si abbassa. Per chiudere il passaggio
bisogna dare l’impulso di chiusura.
3
DIP-SWITCH N° 3:
ON: Chiude in automatico
OFF: Non chiude in automatico.
Funzione semiautomatico
T2
TEMPO DI PAUSA
1 s - 180 s
-
+
Orologio esterno (optional):
OROLOGIO: il programmatore Elpro S50-T1 consente il collegamento di un normale orologio per la salita e
la discesa del dissuasore.
Collegamento: collegare in parallelo il contatto NA dell’orologio con il morsetto n° 4 apre e n° 3 comune,
attivando la richiusura automatica con il Dip-Switch n° 3 = ON.
Funzionamento: programmare l’orario di apertura sull’orologio, all’ora impostata il dissuasore si abbassa e
la spia segnala con 2 brevi lampeggi seguiti da una pausa più lunga), e non accetterà più nessun comando
(anche radio) sino allo scadere del tempo impostato sull’orologio, allo scadere del quale dopo il tempo di
pausa seguirà la salita automatica.
DIP-SWITCH N° 8 e N° 9:
Schedina semaforo ad innesto (optional):
L’alimentazione della schedina è indipendente da quella
della scheda del programmatore:
- 230 V - 50 Hz con uscita di 100 W a 230 V per lampada.
- 24 V con uscita di 25 W per lampada.
- 12 V con uscita di 22 W per lampada.
Funzionamento anche per semaforo a 2 lampade rosso
e verde (Dip Switch 8 = OFF e 9 = OFF).
Logica di Funzionamento:
- Luce VERDE = colonna abbassata, passaggio APERTO
- Luce ROSSA = colonna in movimento o alzata,
passaggio CHIUSO
- Luce GIALLA = interviene prima del passaggio da
luce verde a luce rossa.
Nota: In funzionamento pedonale il semaforo rimane
sempre ROSSO.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF e 9 = OFF
Si accende il giallo per tempo 0 s e
dopo 0 s si accende il rosso e si alza
la colonna immediatamente.
Dip-Switch 8 = ON e 9 = OFF
Si accende il giallo per tempo 2 s,
poi si accende il rosso e dopo 2 s si
alza la colonna.
Dip-Switch 8 = OFF e 9 = ON
Si accende il giallo per tempo 6 s,
poi si accende il rosso e dopo 5 s si
alza la colonna.
Dip-Switch 8 = ON e 9 = ON
Si accende il giallo per tempo 10 s,
poi si accende il rosso e dopo 7 s si
alza la colonna.
ROSSO
GIALLO
VERDE
Rossa
Gialla
Verde
Fusibile 1 A
(Optional: schedina semaforo
ad innesto per lampade a 230 V,
24 V o 12 V).
Codice 7282L
Rosso
Giallo
Verde
Alimentazione
230 V - 50 Hz,
24 V o 12 V
Comune
63 64 65 66 60 61
ALIMENTAZIONE
QUADRO 230 V ± 10%
50 Hz MONOFASE
FN
COMUNE LED
E/O CICALINO
CICALINO
51 52 53
PROGRAMMATORE PER DISSUASORI A SCOMPARSA ANTITERRORISMO
TALOS M50
Elpro S50-T1
IT
6
GENERAL WARNINGS FOR PEOPLE SAFETY
THANK YOU
Thank you for purchasing a Fadini product.
Please read these instructions carefully before using this
appliance. The instructions contain important information
which will help you get the best out of the appliance and
ensure safe and proper installation, use and maintenance.
Keep this manual in a convenient place so that you can always
refer to it for the safe and proper use of the appliance.
INTRODUCTION
This operator is designed for a specic scope of applications as
indicated in this manual, including safety, control and signaling
accessories as minimum required with Fadini equipment. Any
applications not explicitly included in this manual may cause
operation problems or damages to properties and people.
Meccanica Fadini S.r.l. is not liable for damages caused by the
incorrect use of the equipment, or for applications not included
in this manual or for malfunctioning resulting from the use of
materials or accessories not recommended by the
manufacturer. The manufacturer reserves the right to make
changes to its products without prior notice. All that is not
explicitly indicated in this manual is to be considered not
allowed.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability
of the access, its general condition and the structure. Make
sure that there is no risk of impact, crushing, shearing,
conveying, cutting, entangling and lifting situations, which
may prejudice people safety. Do not install near any source of
heat and avoid contacts with ammable substances. Keep all
the accessories able to turn on the operator (transmitters,
proximity readers, key-switches, etc) out of the reach of the
children. Transit through the access only with stationary
operator. Do not allow children and/or people to stand in the
proximity of a working operator. To ensure safety in the
whole movement area of a gate it is advisable to install
photocells, sensitive edges, magnetic loops and detectors.
Use yellow-black strips or proper signals to identify dangerous
spots. Before cleaning and maintenance operations,
disconnect the appliance from the mains by switching o the
master switch. If removing the actuator, do not cut the
electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied
technician, in observance of the Machinery Directive
2006/42/CE and safety regulations EN 12453 - EN 12445.
Verify the presence of a thermal-magnetic circuit breaker 0,03
A - 230 V - 50 Hz upstream the installation. Use appropriate
objects to test the correct functionality of the safety
accessories, such as photocells, sensitive edges, etc. Carry out
a risk analysis by means of appropriate instruments measuring
the crushing and impact force of the main opening and closing
edge in compliance with EN 12445. Identify the appropriate
solution necessary to eliminate and reduce such risks. In case
where the gate to automate is equipped with a pedestrian
entrance, it is appropriate to prepare the system in such a way
to prohibit the operation of the engine when the pedestrian
entrance is used. Apply safety nameplates with CE marking
on the gate warning about the presence of an automated
installation. The installer must inform and instruct the end
user about the proper use of the system by releasing him a
technical dossier, including: layout and components of the
installation, risk analysis, verication of safety accessories,
verication of impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive
information concerning only the operation of the installation
so that he becomes himself responsible for the correct use of it.
The end-user shall establish a written maintenance contract
with the installer/maintenance technician (on -call).
Any maintenance operation must be done by qualied
technicians. Keep these instructions carefully.
WARNINGS FOR THE CORRECT OPERATION OF THE
INSTALLATION
For optimum performance of system over time according to
safety regulations, it is necessary to perform proper
maintenance and monitoring of the entire installation: the
automation, the electronic equipment and the cables
connected to these. The entire installation must be carried
out by qualied technical personnel, lling in the Maintenance
Manual indicated in the Safety Regulation Book (to be
requested or downloaded from the site
www.fadini.net/supporto/downloads). Operator:
maintenance inspection at least every 6 months, while for the
electronic equipment and safety systems an inspection at least
once every month is required. The manufacturer, Meccanica
Fadini S.r.l., is not responsible for non-observance of good
installation practice and incorrect maintenance of the
installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as
cardboard, nylon, polystyrene etc. through specializing
companies (after verication of the regulations in force at the
place of installation in the eld of waste disposal). Disposal of
electrical and electronic materials: to remove and dispose
through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is
prohibited.
UE DECLARATION OF CONFORMITY (DoC)
Manufacturer: Meccanica Fadini S.r.l.
Address: Via Mantova, 177/A - 37053 Cerea - VR - Italy
declare that the DoC is issued under our sole responsibility and
belongs to the following product:
Control unit model ELPRO S50-T1
is in conformity with the relevant Union harmonisation legislation:
- Electromagnetic Compatibility Directive 2014/30/UE
- Low Voltage Directive 2014/35/UE
Cerea, 13/10/2017 Meccanica Fadini S.r.l.
Responsible Manager
7
GB CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Elpro S50-T1
NOTE WELL:
- The control panel must be installed in a sheltered, dry place.
- Fit the mains to the control panel with a 0,03 A high sensitivity magneto-thermal circuit breaker.
- Use a multipole cable type BUT FLESSIBILE FG 70R 12x1,5 mm², up to a recommended distance of 20 m maximum between TALOS M50 and ELPRO S50-T1.
- For distances longer than 20 m use cables having an adequate section in compliance with the rules of good installation praxis.
- Use 1 mm² section wires for command and safety accessories.
N.W: To t extra accessories such as lights, CCTV etc. use only solid state relays to prevent interference with the microprocessor.
24 25
57 58
55 56
12345678910
ELPRO S20
T2
DWELL TIME
1 s - 180 s
T1
MOTOR RUN TIME
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9L5
ON
OFF
14567823 9101112
CONNECTOR FOR TRAFFIC LIGHT
WITH 3 LAMPS MAX 100 W
EACH LAMP
24 Vdc OUTPUT
DIP-SWITCH
Elpro S20
Input P
DO NOT USE
(pedestrians)
Photocells
24 V - 250 mA Output. Max. load:
- n° 2 pairs. Photocells
- n° 1 radio receiver
COMMON
OPEN
CLOSE
STOP
RADIO
Light 24 V - 3 W max
Transformer
secondary
fuse
F4 = 2 A
Fuse for solenoid valve, beeper,
asher and LEDs F5 = 2 A
M2 motor fuse
F2 = 1 A
M1 motor fuse
F1 = 1 A
PLUG-IN
RADIO CARD
CONNECTOR
Transformer
primary
fuse
F3 = 630 mA
20 VA - 50/60 Hz
TRANSFORMER
Anti-disturbance lter
+-
51 52 53
-
+
-
+
Bollard
MOTOR 1
BEEPER
SIGNALLING LEDs
230 V - 100 W max
BOARD POWER
SUPPLY 230 V ± 10%
50 Hz SINGLE-PHASE
COMMON
FN
55 56
16
17 18 51 52 53
55 56
70 71 72 51 52 53
COMMON
M1
limit switch +24 Vdc
brown wires of the blue and grey cables
limit switch GND
green wires of the blue and grey cables
+-
11 12
11 12
11 12
limit switch opening TALOS 1
grey cable - white wire
limit switch closing TALOS 1
blue cable - white wire
F=20 A
24 25 Electronic
circuit breaker
with capacitor
M1 40 μF
71
72
70
black
Motor 1
Capacitor
40 μF
7271
Motor 1
Capacitor
40 μF
7271
L10 L11
Contactor
LOWERING
M1
Contactor
RISING
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1 24
25
24
25
32
33
31
31
70
71
72
70
GB CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Elpro S50-T1
8
Note well: whenever Elpro S50-T1 is re-powered, wait 10 seconds for the logic to become fully operating again.
Accessory Electrical connections Dip-switches and LED status of the various functions
IN CASE OF FAILURE OF THE CONTROL BOARD:
- Make sure voltage supply to the electronic board is 230 V ±10% - 50 Hz
- Make sure voltage supply to the electric motor is 230 V ±10% - 50 Hz
- For distances beyond 20 meters increase wire section
- Check power supply 230 V single-phase
- Check fuses
- Check all NC contacts of the control board
- Check that no voltage drop has occurred from the control board to the electric motor
LED DIAGNOSTICS
L1 = Open for pedestrians, normally OFF, do not use
L2 = Photocells, normally ON, it goes o in case of obstruction
L3 = Open, normally OFF, it goes on by pulsing to open
L4 = Close, normally OFF, it goes on by pulsing to close
L5 = Stop, normally ON, it goes o by pulsing to stop
L6 = Radio, normally OFF, it goes on by pulsing the radio
L7 = Normally ON, line voltage and integrity of F1, F2, F3, F4 fuses
L8 = M1 limit switch open, normally ON, o with post 1 in down position
L9 = M1 limit switch close, normally ON, o with post 1 in raised position
L10 = Deactivated
L11 = Deactivated
L12 = Deactivated
L13 = Deactivated
L14 = Deactivated
L15 = Deactivated
DIP-SWITCHES
1 = ON Photocells. Stop in opening
2 = ON Radio. No travel reversing in opening
3 = ON Automatic closing
4 = ON Pre-ashing. Flasher activated
5 = ON Radio step by step, stop in between
6 = do not use
7 = ON deadman (hold-on-switched) control
8 = Trac lights control (see functions box)
9 = Trac lights control (see functions box)
10 = ON Flasher o in dwell time
11 = ON Close in dwell time after passing between photocells
12 = ON Motor run time max. 90 s. OFF = 18 s
Symbols
NO Contact
NC Contact
Led ON
Led OFF
Indication light or
lamp
Flasher
ON
OFF
14567823 9101112
DIP-SWITCHES
Photocells:
Key-switch:
Radio contact:
1
DIP-SWITCH N° 1:
ON: Photocells. Stop while opening,
reverse in closing once obstacle is removed
OFF: Photocells. No stop while opening, reverse
in closing in case of an obstacle
2
DIP-SWITCH N° 2:
ON: No reversing in opening
OFF: Travel reversing on each pulse
5
DIP-SWITCH N° 5:
ON: Step by step mode with stop in between
OFF: Standard functioning
11
DIP-SWITCH N° 11:
ON: During dwell time, automatic mode,
(Dip-Switch 3 = ON) after engaging the
photocells, it closes after 5 s
OFF: no closing after engaging the photocells
NC
COMMON
COMMON
OPEN
CLOSE
STOP
12
NC
910
Photocells
24 V - 250 mA Output - max. load:
- n° 2 pairs of photocells
- n° 1 radio receiver
With any NO contact to the two terminals,
the following is performed on each pulse:
- Opening only: Dip 2 = ON and Dip 5 = OFF
- Travel reversing
Dip 2 = OFF and Dip 5 = OFF
- Step by step: open - stop - close - stop
Dip 2 = OFF and Dip 5 = ON
- No further command accepted on opening.
Stop and reversing performed on dwell time
and closing:
Dip 2 = ON and Dip 5 = ON
NO and NC contacts to be connected to the
respective terminals of the key-switches or
push-buttons.
All possible congurations are described in
the instructions attached to the respective
control accessory
3456
NC
RADIO CONTACT
3 7
L3 OFF = no contact to open, it goes on
whenever a pulse to open is given
L4 OFF = no contact to close, it goes on
whenever a pulse to close is given
L5 ON = stop contact closed, it goes o
whenever a pulse to stop is given
L2 ON = no obstruction. It goes o in case of an
obstacle
L7 OFF = no RADIO contact, it goes on henever
a radio pulse is given
GB CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Elpro S50-T1
9
COMMON
51 52 53 4
DIP-SWITCH N° 4:
ON: Pre-ashing
OFF: No pre-ashing
10
DIP-SWITCH N° 10:
ON: Flasher. Deactivated during dwell time,
automatic mode
OFF: Flasher. Activated during dwell time,
automatic mode
External
asher: It is possible to connect an external ashing
lamp to the bollard in addition to the
incorporated LED lights. The asher will be
on during the rising and lowering
movements and during the dwell time (if
pre-selected)
230 V - 100 W max
12
DIP-SWITCH N° 12:
ON: Motor run time max. 90 s
OFF: Motor run time max. 18 s
Light on = post down, gateway cleared
Light o = post up, gateway closed
Flashing 0,5 s (fast) = post moving up
Flashing 1 s (normal) = post moving down
With an external time clock: 2 short ashes followed by a longer pause
Output for any possible 24 Vdc application
COMMON
3 8
Accessory Electrical connections Dip-switches and LED status of the various functions
24 V - 3 W max.
Light indicating
bollard in motion :
24 Vdc output:
Motors:
Limit switches:
+-
T2
DWELL TIME
1 s - 180 s
T1
MOTOR RUN TIME
1 s - 22 s
-
+
-
+
55 56
Signalling LED lights:
Output for the LED lights that are always on
blinking during the rising and lowering
movements of the post and with the post in
standing position. They go o with post in
down position.
200 mA for the accessories
LEDs or BEEPER
COMMON
LEDs
51 52 53
11 12 55 56 L8 ON = it goes o with post 1 down
L9 ON = it goes o with post 1 up
Bollard 1
MOTOR 1
16 17 18
M1
COMMON
L10 ON = it goes o with post 2 down
L11 ON = it goes o with post 2 up
limit switch opening TALOS 1
grey cable - white wire
limit switch closing TALOS 1
blue cable - white wire
limit switch +24 Vdc
brown wires
of the blue and grey cables
limit switch GND
green wires
of the blue and grey cables
L12 ON = it goes o with post 3 down
L13 ON = it goes o with post 3 up
Important: if the bollard does not operate in
phase with the open/close commands as
required, swap connections to 17/18.
GB CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Elpro S50-T1
10
Elpro S50-T1
board and PC controller
power supply
BOARD POWER SUPPLY
230 V ± 10%
50 Hz SINGLE-PHASE
FN
3
DIP-SWITCH N° 3:
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic mode
T2
DWELL TIME
1 s - 180 s
-
+
FUNCTIONS
The acoustic device is inside the post and
is on only during the rising and lowering
movements of the post.
Beeper, post in motion:
Board power supply:
Description Dip-switches and LED status of the various functions
7
DIP-SWITCH N° 7:
ON: Deadman control
OFF: Standard operating mode
Deadman control:
Open and Close operations are achieved “by holding a switch on” (no relay
self-holding is involved). Therefore, a physical attendance is required during
the entire cycle of movements until either the button or key is released.
Automatic / semiautomatic:
Automatic cycle: after a pulse to open, the bollard goes down, it stays stopped as long as the dwell
time lasts, as pre-set by T2 trimmer, and on expiring of such time it goes up automatically.
Semi-Automatic cycle: after a pulse to open, the bollard goes down.
Another pulse is needed to close the gateway.
3
DIP-SWITCH N° 3:
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic operating mode
T2
DWELL TIME
1 s - 180 s
-
+
External time clock (optional):
CLOCK: the Elpro S50-T1 controller allows for a normal clock to be connected to it commanding the post
to rise and lower.
Connections: parallel connect the NO contact of the clock to the terminals No. 4 open and No. 3 common,
and set the controller to automatic mode by Dip-Switch n° 3 = ON.
How it works: set the clock to the required opening time. On the pre-set time the post is automatically
lowered ( the indication light emits 2 short ashes followed by a longer pause). Any further
command/pulsing (even by remote control) is not accepted by the system until the time pre-set on the
clock is expired. On expiring of it, and after the pre-set dwell time, the post rises
automatically.
DIP-SWITCHES N° 8 and N° 9:
Plug-in trac lights card (optional):
The power supply of the trac lights card is independent
from that of the electronic control board:
- 230 V - 50 Hz with an output of 100 W at 230 V ea. lamp.
- 24 V with an output of 25 W each lamp.
- 12 V with an output of 22 W each lamp.
Functioning applies also to trac lights with 2 lamps, red
and green (Dip Switch 8 = OFF and 9 = OFF).
Functioning logic:
- GREEN Light= post down, gateway OPEN
- RED Light = post moving or standing,
gateway CLOSED
- YELLOW Light = it switches on before green turns
to red light.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF and 9 = OFF
Yellow turns on for 0 s and after 0 s
red turns on and the post starts
rising immediately
Dip-Switch 8 = ON and 9 = OFF
Yellow turns on for 2 s, then red
turns on and after 2 s the post
starts rising
Dip-Switch 8 = OFF and 9 = ON
Yellow turns on for 6 s, then red
turns on and after 5 s the post
starts rising
Dip-Switch 8 = ON and 9 = ON
Yellow turns on for 10 s, then red
turns on and after 7 s the post
starts rising
RED
YELLOW
GREEN
Red
Yellow
Green
Fuse 1 A
(Optional: plug-in trac lights
card at a 230 V, 24 V or 12 V).
Item Code No. 7282L
Red
Yellow
Green
Power supply
230 V - 50 Hz,
24 V or 12 V
Common
63 64 65 66 60 61
BEEPER or
LED. COMMON
BEEPER
51 52 53
GB CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Elpro S50-T1
11
Accessory Electrical connections Dip-switches and LED status of the various functions
AVERTISSEMENTS DE SECURITE AUX USAGERS
NOUS VOUS REMERCIONS
Nous vous remercions d'avoir acheté un produit Fadini.
Veuillez lire attentivement ces instructions avant d’utiliser
l'appareil. Ces instructions sont des informations utiles vous
permettant de mieux exploiter cet appareil,et vous assurer une
installation, une utilisation et un entretien sécurisés et adéquats.
Veuillez bien garder ce manuel et toujours vous y référ pour une
utilisation sécurisée et adéquate de l'appareil.
INTRODUCTION
Cet automatisme a été conçu pour une utilisation qui respecte ce
qu'il y a indiqué dans ce livret, avec les accessoires de sécurité et de
signalisation minimaux demandés et avec les dispositifs Fadini.
Toute autre application pas expressément indiquée dans ce livret
pourrait provoquer des dysfonctionnements ou des dommages à
choses et personnes. Meccanica Fadini n'est pas responsable
d'éventuels dommages provoqués par une utilisation impropre et
non spéciquement indiquée dans ce livret. En outre, elle n'est pas
responsable des dysfonctionnements causés de l'usage de
matériels ou accessoires non recommandés par le fabricant.
L'entreprise de construction se réserve le droit d'apporter des
modications aux propres produits sans préavis. Tout ce qui n'est
pas prévue dans cette notice d'installation n'est pas permis.
INSTRUCTIONS A SUIVRE AVANT L'INSTALLATION
Contrôler avant toute intervention que l'entrée soit adapté à
l'automatisation, ainsi que ces conditions et structure.
Assurez-vous qu'y ne soit pas des risques d'impact, écrasement,
cisaillement, convoyage, entraînement et enlèvement, tells qu'on
pourrait aecter la sécurité des personnes. Installer
l'automatisme loin de tout sources de chaleur et éviter le contact
avec substances inammables. Garder tout dispositifs de
contrôle automatisme (émetteurs, lecteurs de proximité,
sélecteurs etc) hors de la portée des enfants. Transiter à travers la
zone du mouvement du portail seulement lorsque l'automatisme
est fermé. An de garantir un niveau de sécurité adéquat de
l'installation il est nécessaire d'utiliser photocellules, listeaux
sensibles, spires magnétiques, détecteurs de masse métalliques,
en assurant la sécurité de tout l'aire de mouvement du portail.
Identier les points dangereux de l'installation en l'en indiquant
avec bandes jaune-noir ou autres signaux appropriés. Couper
l'alimentation avant toute intervention d'entretien ou nettoyage
de l'installation. Dans le cas on doit enlever l’opérateur du
portail, ne pas couper les ls électrique; mais les débrancher en
desserrant les vis du bornier.
L'INSTALLATION
Toute l'installation doit être accomplie par personnel technique
qualié et autorisé, conformément à la directive Machines
2006/42/CE et, notamment, aux normes EN 12445 et EN 12453.
Vérier la présence en amont de l'installation d'un interrupteur
diérentiel magnétothermique de 0,03 A de courant 230 V - 50 Hz.
Utiliser des objets approprié pour eectuer les tests de
fonctionnement des photocellules, détecteurs des masses
métalliques, listeaux sensibles, etc. Eectuer une analyse des
risques, en utilisant instruments de détection de l'impact et
écrasement du bord principale d’ouverture et fermeture,
conformément aux normes EN 12445. Dénir les solutions
appropriées pour éliminer ou réduire tels risques. Dans le cas où
le portail à automatiser aurait doué d'une entrée piétonne, il serait
bon d'accomplir l'installation de façon que le moteur ne
fonctionne pas lorsque l'entrée piéton est utilisé. Fournir des
indications concernant la position de l’installation en appliquant
sur le portail des plaquettes de signalisation marquée CE.
L'installateur doit informer l'utilisateur sur le fonctionnement
correct du système, en lui remettant le dossier technique signé,
incluant: le schéma et les éléments composants l'installation,
l'analyse des risques, la vérication des accessoires de sécurité, la
vérication de la force d'impact et la déclaration des risques
résiduels.
INDICATIONS POUR L'UTILISATEUR FINAL
L'utilisateur doit consulter et recevoir information relative au
fonctionnement de l'installation et il devient lui-même
responsable du bon usage du système. Il faut qu'il conclue un
contrat d'entretien ordinaire et extraordinaire (sur appel) avec
l'installateur/réparateur. Toute l’intervention d'entretien doivent
être accompli par des techniciens qualiés. Conserver toujours
la notice d'installation.
AVERTISSEMENTS POUR LE FONCTIONNEMENT CORRECT DE
L'INSTALLATION
Pour que l’installation fonctionne correctement de façon durable
et conformément aux normes de sécurité en vigueur, vous devez
faire eectuer un entretien correct et le monitorage de toute
l’installation au niveau de l’automation, des appareils
électroniques installés et des câblages qui y sont branchés.
Toute l'installation doit être eectuée par un technicien qualié,
qui doit remplir le Manuel d'Entretien indiqué dans le Livret des
Normes (à demander ou télécharger sur le site
www.fadini.net/supporto/downloads). L'automation: contrôle
d'entretien tous les 6 mois au moins, tandis que le contrôle
d'entretien des appareils électroniques et systèmes de sécurité
doit être accompli une fois par mois au moins. Meccanica Fadini
S.r.l. n'est pas responsable de l'éventuel non-respect des règles de
bonne technique d'installation et/ou de l'entretien incorrect du
système.
RAMASSAGE DES MATERIAUX
Les éléments d'emballage, tels que le carton, nylon, polystyrène,
etc. peuvent être recyclés avec le collecte séparé (en vériant la
réglementation en vigueur en la matière dans le pays où le
dispositif est monté). Les composants électriques et
électroniques, les batteries peuvent contenir des substances
polluantes: enlever et coner tels composants aux sociétés
chargées du traitement et de l’élimination des déchets, dans le
respect de la directive 2012/19/UE. Ne pas jeter déchets nuisibles
à l'environnement.
Meccanica Fadini S.r.l.
Directeur Responsable
DECLARATION UE DE CONFORMITE
Fabricant: Meccanica Fadini S.r.l.
Adresse: Via Mantova, 177/A - 37053 Cerea - VR - Italy
déclare sous sa propre responsabilité que le produit:
Programmateur électronique modèle ELPRO S50-T1
il est conforme à la législation d'harmonisation de l'Union:
- Directive Compatibilité Electromagnétique 2014/30/UE
- Directive Basse Tension 2014/35/UE
Cerea, 13/10/2017
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50
Elpro S50-T1
FR
12
Attention: chaque fois que l'Elpro S50-T1 est remis sous tension, attendez 10 secondes pour que la logique redevienne pleinement opérationnelle.
NOTE BIEN:
- Le programmateur doit être installé dans un endroit protégé et sec.
- Appliquez un disjoncteur magnéto-thermique de haute sensibilité de 0,03 A à l’alimentation du programmateur.
- Utilisez un câble multipolaire type BUT FLEXIBLE FG 70R 12x1,5 mm², jusqu'à une distance recommandée de 20 m maximum entre TALOS M50 et ELPRO S50-T1.
- Pour des distances supérieures à 20 m, utilisez des câbles ayant une section adéquate conformément aux règles de la bonne pratique d'installation.
- Utilisez des ls de 1 mm² pour les accessoires de commande et de sécurité.
N.B: Pour monter des accessoires supplémentaires tels que des lumières, CCTV etc. n'utilisez que des relais statiques pour éviter toute interférence avec le
microprocesseur.
24 25
57 58
55 56
12345678910
ELPRO S20
T2
TEMPS DE PAUSE
1 s - 180 s
T1
TEMPS DE TRAVAIL
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9L5
ON
OFF
14567823 9101112
CONNECTEUR POUR FEU DE CIRC.
A 3 VOYANTS MAX 100 W
PAR VOYANT
SORTIE 24 Vcc
DIP-SWITCH
Elpro S20
Entrée P
NE PAS UTILISER
(piétons)
Photocellules
Sortie 24 V - 250 mA pour charge max:
- n° 2 paires de photocellules
- n° 1 récepteur radio
COMMUN
OUVRE
FERME
ARRET
RADIO
VOYANT 24 V - 3 W max
Fusible
Secondaire
Transformateur
F4 = 2 A
Fusible électrovanne, beeper,
lampe clign. et led F5 = 2 A
Fusible moteur M2
F2 = 1 A
Fusible moteur M1
F1 = 1 A
SUPPORT POUR
CARTE RADIO
ENFICHABLE
Fusible
primaire
transformateur
F3 = 630 mA
20 VA - 50/60 Hz
TRANSFORMATEUR
Filtre anti-perturbation
+-
51 52 53
-
+
-
+
MOTEUR 1
borne escamotable
BEEPER
LED DE SIGNALISATION
230 V - 100 W max
ALIMENTATION
TABLEAU 230 V ± 10%
50 Hz MONOPHASEE
COMMUN
FN
55 56
16
17 18 51 52 53
55 56
70 71 72 51 52 53
COMMUN
M1
n de course +24 Vdc
ls marrons câbles bleu et gris
n de course mise à la terre
ls verts câbles bleu et gris
+-
11 12
11 12
11 12
n de course ouverture TALOS 1
câble gris - l blanc
n de course fermeture TALOS 1
câble bleu - l blanc
F=20 A
24 25 Electronic
circuit breaker
with capacitor
M1 40 μF
71
72
70
noir
Condensateur
Moteur 1
40 μF
7271
Condensateur
Moteur 1
40 μF
7271
L10 L11
Contacteur
DESCENTE
M1
Contacteur
MONTEE
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1 24
25
24
25
32
33
31
31
70
71
72
70
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50
Elpro S50-T1
FR
13
Accessoire Raccordements électriques Dips-switch et LED des diérentes fonctions
EN CAS DE PANNE DE FONCTIONNEMENT DU PROGRAMMATEUR
- Assurez-vous que le programmateur électronique soit alimenté à 230 V ± 10% - 50 Hz
- Assurez-vous que le moteur électrique soit alimenté à 230 V ± 10% - 50 Hz
- Pour distances supérieures à 20 mètres, augmentez la section des ls
- Vériez l'alimentation 230 V monophasée
- Vériez les fusibles
- Vériez tous les contacts NF du programmateur
- Vériez qu'aucune chute de tension ne s'est produite entre le programmateur et le moteur électrique
LED DE CONTROLE
L1 = Ouverture pour les piétons, normalement ETEINTE, ne pas utiliser
L2 = Photocellules, normalement ALLUMEE, elle s'éteint en cas d'obstacle
L3 = Ouverture, normalement ETEINTE, s’allume à limpulsion ouvre
L4 = Fermeture, normalement ETEINTE, s’allume à l’impulsion ferme
L5 = Arrêt, normalement ALLUMEE, s'éteint à l’impulsion arrêt
L6 = Radio, normalement ETEINTE, s’allume à limpulsion radio
L7 = Normalement ALLUMEE, tension de reseau et intégrité des fusibles F1, F2, F3, F4
L8 = Fin de course ouverture M1, normalement ALLUMEE, éteinte avec la colonne en position baissée
L9 = Fin de course fermeture M1, normalement ALLUMEE, éteinte avec la colonne en position levée
L10 = pas active
L11 = pas active
L12 = pas active
L13 = pas active
L14 = pas active
L15 = pas active
DIPS-SWITCH
1 = ON Photocellule. Arrêt à l’ouverture
2 = ON Radio n’inverse pas à l’ouverture
3 = ON Ferme en automatique
4 = ON Pré-clignotement lampe clignotante actif
5 = ON Radio pas-pas avec arrêt intermédiaire
6 = ne pas utiliser
7 = ON Service homme mort
8 = Gestion du feu de circulation (voir le tableau des fonctions)
9 = Gestion du feu de circulation (voir le tableau des fonctions)
10 = ON Lampe clignotante éteinte en pause
11 = ON Referme en pause après le passage des photocellules
12 = ON Temps de travail 90 s. maximum OFF = 18 s
Symbologie
Contact NO
Contact NF
Led allumée
Led éteinte
Voyant ou lampe
Lampe clignotante
ON
OFF
14567823 9101112
DIP-SWITCH
Photocellules:
Sélecteur à clé:
Contact radio:
1
DIP-SWITCH N° 1:
ON: Photocellule. Arrête à l’ouverture et inverse
à la fermeture avec l’enlèvement de l’obstacle
OFF: Photocellule. N’arrête pas à l’ouverture et
inverse à la fermeture avec un obstacle
2
DIP-SWITCH N° 2:
ON: N’inverse pas à l’ouverture
OFF: Inverse la marche à chaque impulsion
5
DIP-SWITCH N° 5:
ON: Pas-pas avec arrêt intermédiaire
OFF: Fonctionnement normal
11
DIP-SWITCH N° 11:
ON: Pendant la pause en automatique
(Dip-Switch 3 = ON) après le passage devant
les photocellules, ferme après 5 s
OFF: Ne ferme pas au moment du passage devant
les photocellules
NF
COMMUN
COMMUN
OUVRE
FERME
ARRET
12
NF
910
Photocellules
Sortie 24 V - 250 mA pour charge max:
- n° 2 paires de photocellules
- n° 1 récepteur radio
En raccordant un n’importe quel contact NO
entre les deux bornes on peut avoir à
chaque impulsion:
- Seulement ouverture:
Dip 2 = ON et Dip 5 = OFF
- Inversion de marche à chaque impulsion
Dip 2 = OFF et Dip 5 = OFF
- Pas-pas: ouvre - arrêt- ferme - arrêt
Dip 2 = OFF et Dip 5 = ON
- En phase d’ouverture il n’accepte aucune
commande. En pause et en fermeture à chaque
commande il fait l’arrêt avec l’inversion de
marche: Dip 2 = ON et Dip 5 = ON
Contacts NO et NF à brancher sur les bornes
correspondantes des sélecteurs ou des boîtes
boutons poussoirs. Toutes les possibles
congurations sont jointes aux accessoires
de commande réspectifs.
3456
NF
CONTACT RADIO
3 7
L3 éteinte = aucun contact ouvre, elle s’allume à
chaque impulsion d’ouverture
L4 éteinte = aucun contact ferme, elle s’allume à
chaque impulsion de fermeture
L5 allumée = contact d’arrêt fermé, elle séteint à
chaque impulsion d’ârret
L2 allumée = aucun obstacle, elle s’éteint à la
présence de l’obstacle
L7 éteinte = aucun contact RADIO, elle s’allume
à chaque impulsion du contact radio
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50
Elpro S50-T1
FR
14
COMMUN
51 52 53 4
DIP-SWITCH N° 4:
ON: Pré-clignotement
OFF: Sans pré-clignotement
10
DIP-SWITCH N° 10:
ON: Clignotement desactivé pendant la pause
en automatique
OFF: Clignotement activé pendant la pause en
automatique
Lampe clignotante
externe: On peut raccorder aussi, en plus des leds
intégrées dans la borne escamotable, une
lampe clignotante externe.
Cela fonctionnera pendant la montée et la
descente et pendant la pause (si elle est
dénie).
230 V - 100 W max
12
DIP-SWITCH N° 12:
ON: Temps de travail max 90 s
OFF: Temps de travail max 18 s
Voyant allumé = colonne baissée, passage libre
Voyant éteint = colonne levée, passage fermé
Clignotement à 0,5 s (rapide) = mouvement de montée
Clignotement à 1 s (normal) = mouvement de descente
Avec horloge externe: 2 brefs clignotements suivis par une pause plus
longue
Sortie pour un possible usager à 24 Vdc
COMMUN
3 8
Accessoire Raccordements électriques Dips-switch et LED des diérentes fonctions
Voyant 24 V - 3 W max
pour la signalisation
du mouvement:
Sortie 24 Vdc:
Moteurs:
Fin de course:
+-
T2
TEMPS DE PAUSE
1 s - 180 s
T1
TEMPS DE TRAVAIL
1 s - 22 s
-
+
-
+
55 56
Led de signalisation:
Sortie pour leds à lumière intermittente
toujours fonctionnantes pendant le
mouvement de montée et de descente et
en arrêt avec la borne en position levée.
Elles s’éteintent avec la colonne baissée.
200 mA pour accessoires
COMMUN LED
ET/OU BEEPER
LED
51 52 53
11 12 55 56 L8 allumée = s’éteint avec la colonne 1 baissée
L9 allumée = s’éteint avec la colonne 1 levée
MOTEUR 1
Borne
escamotable 1
16 17 18
M1
COMMUN
L10 allumée = s’éteint avec la colonne 2 baissée
L11 allumée = s’éteint avec la colonne 2 levée
n de course ouvert. TALOS 1
câble gris - l blanc
n de course fermet. TALOS 1
câble bleu - l blanc
n de course +24 Vdc
ls marrons câbles bleu et gris
n de course mise à la terre
ls verts câbles bleu et gris
L12 allumée = s’éteint avec la colonne 3 baissée
L13 allumée = s’éteint avec la colonne 3 levée
Important: si la borne escamotable n’est pas en
phase avec les commandes ouvre/ferme,
inverser le 17/18.
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50
Elpro S50-T1
FR
15
Alimentation carte
programmateur et
tableau Elpro S50-T1
ALIMENTATION TABLEAU
230 V ± 10%
50 Hz MONOPHASEE
FN
3
DIP-SWITCH N° 3:
ON: Ferme en automatique
OFF: Ne ferme pas en automatique.
Fonction semi-automatique
T2
TEMPS DE PAUSE
1 s - 180 s
-
+
Accessoire Raccordements électriques Dips-switch et LED des diérentes fonctions
FONCTIONS
Le beeper est dans la borne escamotable et il
est actif seulement pendant le mouvement de
montée et de descente.
Beeper de mouvement:
Alimentation tableau:
Description Dips-switch et LED des diérentes fonctions
7
DIP-SWITCH N° 7:
ON: Fonctionnement à homme mort
OFF: Functionnement normal
Homme mort:
Les opérations d’ouverture et de fermeture sont réalisées “en appuyant un
bouton” (sans auto-maintien des relais). Par conséquent, il est demandée la
présence active de l’opérateur pendant tout le mouvement de l’automation
jusqu’à la relâche du bouton ou de la clé du sélecteur.
Automatique / semi-automatique:
Cycle automatique: à une impulsion de commande ouvre, la colonne s’abaisse et elle arrête en pause
pour le temps reglé sur le trimmer T2. Expiré ce temps, elle se lève automatiquement.
Cycle semi-automatique: à une impulsion de commande ouvre, la colonne s’abaisse. Pour fermer le
passage, il faut donner une impulsion de fermeture.
3
DIP-SWITCH N° 3:
ON: Ferme en automatique
OFF: Ne ferme pas en automatique.
Fonction semi-automatique
T2
TEMPS DE PAUSE
1 s - 180 s
-
+
Horloge externe (en option):
HORLOGE: le programmateur Elpro S50-T1 permet le branchement d’un horloge normal pour la montée et
la descente de la borne escamotable.
Raccordement: raccordez en parallèle le contact NO de l’horloge avec la borne n° 4 ouvre et n° 3 commun,
en activant la refermeture automatique avec le Dip-Switch n° 3 = ON.
Fonctionnement: réglez l’horloge sur le temps d’ouverture demandé, à l’heure établie la borne
escamotable s’abaisse (le voyant signale 2 brefs clignotements suivis par une pause plus longue).
Il n’acceptera plus aucune commande (même radio) jusqu’à l’éxpiration du temps établi sur l’horloge.
A l’éxpiration de ce temps, après le temps de pause, il y aura la montée automatique.
DIP-SWITCH N° 8 et N° 9:
Carte feu de circulation enchable
(en option):
L’alimentation de la carte est indépendante de cela de la
carte du programmateur:
- 230 V - 50 Hz avec sortie de 100 W à 230 V par voyant.
- 24 V avec sortie de 25 W par voyant.
- 12 V avec sortie de 22 W par voyant.
Fonctionnement aussi pour feu de circulation à 2
voyants rouge et vert (Dip-Switch 8 = OFF et 9 = OFF).
Logique de Fonctionnement:
- Lumière VERTE = colonne baissée, passage OUVERT
- Lumière ROUGE = colonne en mouvement ou levée,
passage FERME
- Lumière JAUNE = elle s’allume avant le passage de la
lumière verte à la lumière rouge.
Note: avec le fonctionnement piéton le feu de
circulation est toujours ROUGE.
8OFF 9OFF
8
ON
9OFF
8 9
OFF ON
8
ON
9
ON
Dip-Switch 8 = OFF et 9 = OFF
S’allume le jaune pour 0 s
et après 0 s s’allume le rouge et la
colonne se lève immédiatement.
Dip-Switch 8 = ON et 9 = OFF
S’allume le jaune pour 2 s, ensuite
s’allume le rouge et après 2 s, se
lève la colonne.
Dip-Switch 8 = OFF et 9 = ON
S’allume le jaune pour 6 s, ensuite
s’allume le rouge et après 5 s se
lève la colonne.
Dip-Switch 8 = ON et 9 = ON
S’allume le jaune pour 10 s, ensuite
s’allume le rouge et après 7 s se
lève la colonne.
ROUGE
JAUNE
VERT
Rouge
Jaune
Vert
Fusible 1 A
(Option: carte feu de circulation
enchable pour voyants à 230 V,
24 V ou 12 V).
Code 7282L
Rouge
Jaune
Vert
Alimentation
230 V - 50 Hz,
24 V ou 12 V
Commun
63 64 65 66 60 61
COMMUN LED
ET/OU BEEPER
BEEPER
51 52 53
PROGRAMMATEUR POUR BORNE ESCAMOTABLE ANTI-TERRORISME
TALOS M50
Elpro S50-T1
FR
16
DANKE
Danken, dass Sie sich für ein Fadini Produkt entschieden haben.
Bitte lesen Sie diese Gebrauchsanleitung sehr sorgfältig bevor Sie das
Gerät in Betrieb nehmen. Sie enthält wichtige Informationen, damit
Sie viel Freude an Ihrem Gerät haben und ein sicherer und sauberer
Betrieb gewährleistet ist. Bewahren Sie dieses Handbuch gut auf,
damit Sie bei Bedarf immer wieder darauf zurückgreifen können.
EINFÜHRUNG
Diese Automation ist ausschließlich für den in dieser
Betriebsanleitung angegebenen Verwendendungszweck entwickelt
worden, mit den mindesten erforderlichen Sicherhetszubehörteilen,
dem Bedien- und Signalisierungszubehör und Fadini Vorrichtungen.
Jede beliebige andere Anwendung, die nicht extra in diesem
Handbuch angegeben worden ist, könnte zu Funktionsstörungen und
Schäden an Dingen und Personen führen Meccanica Fadini S.r.l. ist
nicht für eventuelle Schäden verantwortlich, die durch nicht gerechte
und nicht spezisch in diesem Handbuch angegebe Verwendung
verursacht werden und haftet außerdem nicht für Betriebsstörungen,
die durch die Verwendung von Materialien oder Zubehörteilen, die
nicht von der Firma selbst angegeben worden sind, entstanden sind.
Die Herstellerrma behält sich Änderungen an eigenen Produkten
ohne Vorankündigung vor Alles, was nicht ausdrücklich in dieser
Anleitung angegeben ist, ist nicht erlaubt.
VOR DER INSTALLATION
Vor jedem Eingri ist die Eignung des zu automatisierenden Eingangs
zu beurteilen, sowie dessen Zustand und Struktur. Stellen Sie sicher,
dass es keine Situationen zum Aufprall, Zerkleinern, Scheren,
Schleppen, Schneiden, Einhaken und Heben entstehen, die die
Sicherheit von Personen gefährden können. Dieses Produkt nicht in
der Nähe von Wärmequellen installieren und der Kontakt mit
brennbaren Stoen vermeiden. Alle Geräte (Sender, Proximity-Leser,
Schalter, etc.) dürfen nicht in die Hände von Kindern gelassen werden.
Übergang ist nur bei der gestoppten Automation erlaubt Lassen
Sie nicht Kinder und / oder Erwachsene, um in der Nähe der Anlage
mit der Automatisierung in Bewegung stehen. Um ein
angemessenes Sicherheitsniveau der Anlage zu gewährleisten ist
notwendig, um die Art der Installationbedienung zu identizieren und
dann im Zusammenhang mit dem Endkunden zu setzen; dann
Lichtschranken, Kontaktleisten, Magnetspulen und Präsenzsensoren
verwenden, um das gesamte betroene Gebiet, um die Bewegung
des Tors (besonders die Ränder der Flügel in Bewegung) gefahrlos zu
machen. Verwenden Sie gelb-schwarze Streifen oder entsprechende
Signale, um die Gefahrenstellen der Installation zu identizieren. Die
Spannung an das System abschalten, wenn Wartung und / oder
Reinigung durchzuführen sind. Wird der Antrieb entfernt, die Drähte
nicht schneiden, aber entfernen Sie sie aus dem Klemmenblock durch
Lösen der Schrauben im Anschlusskasten.
INSTALLATION
Die gesamte Installation muss von qualiziertem technischen
Personal unter Einhaltung der Maschinenrichtlinie 2006/42/CE und
besonders der Normen EN 12445 und EN 12453 durchgeführt werden.
Überprüfen Sie die Anwesenheit aufwärts der Anlage, eines
Magnetothermischen Dierentialhauptschalter 230 V - 50 Hz 0,03 A
Verwenden Sie Testkörper für die Funktionsprüfung in der Erfassung
der Gegenwart, in der Nähe von Sicherheitseinrichtungen wie
Lichtschranken, Sicherheitsleisten, etc.. Führen Sie eine sorgfältige
Risikoanalyse unter Verwendung geeigneter Instrumenten zur
Erkennung von Schlag-und Druck der Vorderkante des Önen und
Schließen, wie in EN 12445 festgelegt. Identizieren Sie die beste
Lösung zur Beseitigung oder Verringerung dieser Risiken. In dem
Fall, wo das Tor zu automatisieren wurde mit einem Fußgänger-
Eingang ausgestattet, ist es zweckmäßig, das System in einer Weise
herzustellen, um den Betrieb des Motors zu verhindern, wenn der
Fußgänger-Eingang verwendet wird. Die Anwesenheit der
Automation mit der Anwendung am Tor eines Warnschilds mit
CE-Kennzeichnung ist zu signalisieren. Das Installateur wird
benötigt, um über die richtige Nutzung des Systems Information und
Aufklärung dem Endkunden zu geben; Layout und Komponenten des
Systems, Risikoanalyse, Überprüfung der Sicherheitsausrüstung,
Überprüfung der Aufprallkräfte und Berichterstattung von
Restrisiken: dies wird durch die Gewährung von ihm einer signierten
Dokumentation denierten technischen Dossiers getan.
HINWEISE FÜR ENDBENUTZER
Der Endbenutzer ist verpichtet, Informationen nur über den Betrieb
des Systems zu empfangen und zu lesen und wird sich für die korrekte
Verwendung verantwortlich. Er muss einen Vertrag für ordentliche
und außerordentliche Wartung (auf Abruf) mit dem Installateur /
Betreuer schließen. Eine Reparatur darf nur von qualiziertem
Fachpersonal durchgeführt werden. Halten Sie diese
Bedienungsanleitung.
HINWEISE UM DEN EINWANDFREIEN BETRIEB DES SYSTEMS
Für eine langfristig optimale Leistung der Anlage entsprechend den
Sicherheitsnormen ist es notwendig die gesamte Anlage durch
qualiziertes Personal korrekt zu warten und zu kontrollieren, sowohl
was die Automation als auch die installierten elektronischen Geräte
und deren Verkabelungen betrit. Die gesamte Anlage muss von
qualizierten Technikern durchgeführt werden, wobei das
Dokuments zur Überprüfung und zum Test und das im Handbuch
Sicherheitsbestimmungen gezeigt Wartungsprotokoll auszufüllen
sind (auf Anfrage oder von der Website www.fadini.net/support/
downloads heruntergeladen). Für die Automatisierung wird
empfohlen, eine Wartungsprüfung mindestens alle 6 Monate,
während für elektronische Geräte und Sicherheitssysteme eine
monatliche Wartung. Meccanica Fadini S.r.l. haftet nicht für die
Nichteinhaltung der regelgerechten Installationstechnik und/oder
unsachgemäße Wartung des Systems.
ENTSORGUNG VON MATERIALIEN
Verpackungsmaterial wie Pappe, Kunststo, Polystyrol, etc.. kann
durch die getrennte Sammlung entsorgt werden (nach Prüfung der
geltenden Bestimmungen am Ort der Installation im Bereich der
Abfallbeseitigung). Elektrischen, elektronischen Elements und
Batterien können Schadstoe enthalten: Entfernen und anvertrauen
diese Komponenten an Unternehmen, die bei der Verwertung von
Abfällen spezialisiert sind, wie in der Richtlinie 2012/19/UE festgelegt.
Es ist verboten, umweltschädliche Materialien in den Hausmüll zu
werfen.
ALLGEMEINE HINWEISE FÜR DIE SICHERHEIT VON PERSONEN
Meccanica Fadini S.r.l.
Betriebsleiter
EU-KONFORMITÄTSERKLÄRUNG
Hersteller: Meccanica Fadini S.r.l.
Adresse: Via Mantova, 177/A - 37053 Cerea - VR - Italy
erklärt auf eigene Verantwortung, dass das Produkt:
Steuerzentrale Modell ELPRO S50-T1
es erfüllt die einschlägigen Harmonisierungsrechtsvorschriften der
Union:
- Richtlinie über Elektromagnetische Verträglichkeit 2014/30/UE
- Niederspannungsrichtlinie 2014/35/UE
Cerea, 13/10/2017
E-STEUERUNG FÜR TALOS M50
ANTI-TERROR VERSENKBARE POLLER
Elpro S50-T1
DE
17
Achtung: Jedes mal dass Elpro S50-T1 mit Strom wieder versorgt wird, warten Sie 10 Sekunden, damit die Steuerlogik regelmäßig wieder funktioniert.
WICHTIG:
- Der Steuerung muss an einem trockenen und geschützten Ort installiert werden.
- An der Stromversorgung der Steuerung einen hochsensiblen magneto-thermischen 0,03 A Dierential-Schalter anbringen.
- Verwenden Sie einen Multipol-Kabeltyp BUT FLESSIBILE FG 70R 12x1,5 mm², bis zu einer empfohlenen Entfernung von 20 m maximum zwischen TALOS M50 und
ELPRO S50-T1.
- Für Enternungen von über 20 m verwenden Sie Kabel mit einer Adernqueschnitt, die den Regeln einer guten Installationpraxis entsprechen.
- Verwenden Sie Kabel mit 1 mm² Adernquerschnitt für Bedienungs-und Sicheheitszubehör.
NB: Für Spezialanwendungen wie z.B. Lichter, Überwachungskameras, usw. muß man statische Relais verwenden, damit es nicht zu Steuerungen am Mikroprozessor kommt.
24 25
57 58
55 56
12345678910
ELPRO S20
T2
PAUSEZEIT
1 s - 180 s
T1
BETRIEBSZEIT
1 s - 22 s
L1 L3L2 L4 L6 L7 L8 L9L5
ON
OFF
14567823 9101112
STECKPLATZ FÜR AMPEL
MIT 3 LICHTERN, MAX 100 W
PRO LICHT
24 Vdc AUSGANG
DIP-SWITCHES
Elpro S20
Input P
VERWENDE NICHT
(Fußgänger)
Lichtschranken
24 V - 250 mA AUSGANG für max.Belastung:
- n° 2 Lichtschranken
- n° 1 Funkempfänger
COMMON
AUF
ZU
STOP
FUNK
Licht 24 V - 3 W max
Sekundär-
sicherung
Transformator
F4 = 2 A
Sicherung für Elektroventil, Piepser,
Blinkleuchte und LEDs F5 = 2 A
M2 Motor Sicherung
F2 = 1 A
M1 Motor Sicherung
F1 = 1 A
STECKSOCKEL FÜR
EINSTECKEMPFÄNGER
Primär-
sicherung
Transformator
F3 = 630 mA
20 VA - 50/60 Hz
TRAFO
Störungsschutzlter
+-
51 52 53
-
+
-
+
Poller
MOTOR 1
PIEPSER
SIGNAL-LEDs
230 V - 100 W max
KARTE STROMVERSORGUNG
230 V ± 10%
50 Hz EINPHASIG
COMMON
FN
55 56
16
17 18 51 52 53
55 56
70 71 72 51 52 53
COMMON
M1
Endschalter + 24 Vdc
braune Drähte, blaue und graune Kabel
Erdung Endschalter
grüne Drähte, blaue und graune Kabel
+-
11 12
11 12
11 12
Önung Endschalter TALOS 1
graunes Kabel - weißer Draht
Schließung Endschalter TALOS 1
blaues Kabel - weißer Draht
F=20 A
24 25
Motor 1
Kondensator
40 μF
7271
Motor 1
Kondensator
40 μF
7271
Electronic
circuit breaker
with capacitor
M1 40 μF
71
72
70
schwarz
L10 L11
Schaltschütz
EINFAHREN
M1
Schaltschütz
AUSFAHREN
M1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1
6T3
22
A2
4T2
2T1
5L3
21L3
A1
3L2
1L1 24
25
24
25
32
33
31
31
70
71
72
70
E-STEUERUNG FÜR TALOS M50
ANTI-TERROR VERSENKBARE POLLER
Elpro S50-T1
DE
18
Zubehör Elektrische Anschlüsse Dip-Schalter u. LED Status der verschiedenen Funktionen
BEI FUNKTIONSSTÖRUNGEN:
- Kontrollieren Sie, daß die Stromversorgung der Steuerung 230 V ±10% - 50 Hz ist
- Kontrollieren Sie, daß die Stromversorgung des E-Motors 230 V ±10% - 50 Hz ist
- Bei Entfernungen über 20 Meter den Adernquesrschnitt der Kabel vergrößern
- Die Versorgungsspannung (230 V einphasig) kontrollieren
- Die Sicherungen kontrollieren
- Alle NC Kontakte der Steuerung kontrollieren
- Kontrollieren, daß kein Spannungsabfall zwischen der Steuerung und dem E-Motor vorliegt
DIAGNOSE-LEDs
L1 = Fußgängerönung, normalerweise OFF, verwenden Sie nicht
L2 = Lichtschranke, normalerweise ON, geht bei vorhandenem Hindernis aus
L3 = Önen, normalerweise OFF, leuchtet bei Betätigung des Impulses Önen auf
L4 = Schließen, normalerweise OFF, leuchtet bei Betätigung des Impulses Schließen auf
L5 = Stopp, normalerweise ON, geht bei Betätigung des Impulses Stop aus
L6 = Funk, normalerweise OFF, leuchtet bei Betätigung des Funks auf
L7 = Normalerweise ON, Netzspannung und Integrität der Sicherungen F1, F2, F3, F4
L8 = M1 Endschalter Önen, normalerweise ON, O bei eingefahrenem Poller
L9 = M1 Endschalter Schließen, normalerweise ON, O bei ausgefahrenem Poller
L10 = Deaktiviert
L11 = Deaktiviert
L12 = Deaktiviert
L13 = Deaktiviert
L14 = Deaktiviert
L15 = Deaktiviert
DIP-SCHALTER
1 = ON Lichtschranke. Es hält beim Önen an
2 = ON Funk. Kein Umkehr beim Önen
3 = ON Autozulauf
4 = ON Vorblinken. Blinkleuchte aktiviert
5 = ON Funk Schritt für Schritt (Impulsbetrieb), mit Zwischenstop
6 = Verwenden Sie nicht
7 = ON Totmann-Betrieb
8 = Ampel Steuerung (Sehen Sie Abschnitt Funktionen)
9 = Ampel Steuerung (Sehen Sie Abschnitt Funktionen)
10 = ON Blinkleuchte O in Pause
11 = ON Es schließt wieder in Pause nach Durchgang durch
Lichtschranke
12 = ON Max. Betriebszeit 90 s. OFF = 18 s
Symbole
NO Kontakt
NC Kontakt
LED ON
LED OFF
Anzeigelicht oder
Leuchte
Blinkleuchte
ON
OFF
14567823 9101112
DIP-SWITCHES
Lichtschranke:
Schlüsselschalter:
Funkkontakt:
1
DIP-SCHALTER Nr. 1:
ON: Lichtschranke. Hält beim Önen an, kehrt beim
Schließen nach Entfernung des Hindernisses um
OFF: Lichtschranke. Hält beim Önen nicht an, kehrt
beim Schließen bei vorhandenem Hindernis um
2
DIP-SCHALTER Nr. 2:
ON: Keine Umkehrung beim Önen
OFF: Kehrt die Laufrichtung bei jedem Impuls um
5
DIP-SCHALTER Nr. 5:
ON: Impulsbetrieb mit Zwischenstopp
OFF: Normalbetrieb
11
DIP-SCHALTER Nr. 11:
ON: Während der Pause, in Automatik,
(Dip-Schalter 3 = ON) schließt beim Durchgang
durch die Lichtschranke nach 5 s
OFF: Es schließt beim Durchgang durch die
Lichtschranke nicht
NC
COMMON
COMMON
AUF
ZU
STOP
12
NC
910
Lichtschranke
24 V - 250 mA Ausgang - max. Belastung:
- Nr. 2 Lichschranken
- Nr. 1 Funkempfänger
Bei jedem NO Anschluss an diese beide Klemmen,
wird es bei jedem Impuls wie folgt ausgeführt:
- Nur Önung: Dip 2 = ON und Dip 5 = OFF
- Laufumkehr bei jeder Impulsgabe
Dip 2 = OFF und Dip 5 = OFF
- Schritt-für-Schritt: Auf - Stop - Zu - Stop
Dip 2 = OFF und Dip 5 = ON
- Beim Önen wird kein weiterer Befehl akzeptiert.
Stop und Umkehr bei Pausezeit und Schließen
wenn ein Impuls gegeben wird:
Dip 2 = ON und Dip 5 = ON
NO und NC Kontakte, die an den
jeweilige Klemmen der Schlüsselschalter oder
Drückknöpfe anzuschliessen sind.
Alle möglichen Kongurationen sind in
der Anweisungen der jeweiligen
Steuerzubehör beschrieben
3456
NC
FUNKKONTAKT
3 7
L3 OFF = Kein AUF Kontakt, es schaltet an,
wann ein Impuls zum Önen gegeben
wird
L4 OFF = Kein ZU Kontakt, es schaltet an,
wann ein Impuls zum Schließen
gegeben wird
L5 ON = Stop-Kontakt geschlossen, es schlatet aus
wann ein Stop-Impuls gegeben wird
L2 ON = Kein Hindernis. Es schaltet bei einem
Hindernis aus
L7 OFF = Kein FUNK KontaKt, es schaltet bei
jeder Funk-Impulsgabe an
E-STEUERUNG FÜR TALOS M50
ANTI-TERROR VERSENKBARE POLLER
Elpro S50-T1
DE
19
COMMON
51 52 53 4
DIP-SCHALTER Nr. 4:
ON: Vorblinken
OFF: Kein Vorblinken
10
DIP-SCHALTER Nr. 10:
ON: Blinkleuchte nicht aktiviert während der Pause
in Automatik
OFF: Blinkt während der Pause in Automatik
Externe
Blinkleuchte: Zusätzlich zu den eingebauten
LED-Leuchten können Sie eine externe
Blinkleuchte an den Poller anschliessen. Die
Blinkleuchte wird während der Auf- und
Abbewegungen und während der Pausezeit
eingeschaltet (falls vorausgewählt).
230 V - 100 W max
12
DIP-SCHALTER Nr. 12:
ON: Max. Betriebszeit 90 s
OFF: Max. Betriebszeit 18 s
Licht ON = Poller eingefahren, Durchfahrt freigeben
Licht OFF = Poller ausgefahren, Durchfahrt gesperrt
Blinken 0,5 s (schnell) = Phase des Hebens
Blinken 1 s (normal) = Phase des Senkens
Mit externer Uhr: 2 kurzes Blinken, gefolgt von einer längerer Pause
Ausgang für eine mögliche Benutzung 24 Vdc
COMMON
3 8
Zubehör Elektrische Anschlüsse Dip-Schalter u. LED Status der verschiedenen Funktionen
24 V - 3 W max.
Anzeigelampe
zur Signalisierung
der Bewegung :
24 Vdc Ausgang:
Motore:
Endschalter:
+-
T2
PAUSEZEIT
1 s - 180 s
T1
MOTOR BETRIEBSZEIT
1 s - 22 s
-
+
-
+
55 56
Signal-LEDs:
Ausgang für LED-Lichter, intermittierend,
die während der Bewegung des Aus- und
Einfahrens und bei ausgefahrenem Poller
ständig funktionieren.
Sie schalten bei eingefahrenem Poller aus.
200 mA für Zubehör
LEDs und/oder PIEPSER
COMMON
LEDs
51 52 53
11 12 55 56 L8 ON = es schaltet bei eingefahrenem Poller 1 aus
L9 ON = es schaltet bei ausgefahrenem Poller 1 aus
Poller 1
MOTOR 1
16 17 18
M1
COMMON
L10 ON = es schaltet bei eingefahrenem Poller 2 aus
L11 ON = es schaltet bei ausgefahrenem Poller 2 aus
Önung Endschalter TALOS 1
graunes Kabel - weißer Draht
Schließung Endschalter TALOS 1
blaues Kabel - weißer Draht
Endschalter + 24 Vdc
braune Drähte, blaue und
graune Kabel
Erdung Endschalter
grüne Drähte, blaue und
graune Kabel
L12 ON = es schaltet bei eingefahrenem Poller 3 aus
L13 ON = es schaltet bei ausgefahrenem Poller 3 aus
Wichtig: Wenn der Poller mit der Befehle
Önen/Schließen nicht korrekt eingestellt ist,
kehren Sie 17/18 um.
E-STEUERUNG FÜR TALOS M50
ANTI-TERROR VERSENKBARE POLLER
Elpro S50-T1
DE
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Fadini elpro-s50-T1 Instructions Manual

Taper
Instructions Manual

dans d''autres langues