Premier Mounts CTM-MS1 Mode d'emploi

Catégorie
Supports muraux à panneau plat
Taper
Mode d'emploi
Installation Guide
CTM-MS1
Tilting Mount for Flat-Panels
premiermounts.com | p. 800.368.9700 | e. [email protected]
500 W Central Ave, Suite A, Brea, CA 92821 USA
Warning Statements
Weight Limit
Maximum Flat Panel Weight: 160 lb. THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING AT
LEAST FOUR TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, THE
WALL STRUCTURE MUST BE REINFORCED.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND COMPLETELY
UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED IN THESE
INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR
EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY
EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR
PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR
MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION
OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR
MODIFICATIONS.
If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs or ceiling studs.
It is recommended that a maximum of ⅝˝ plaster board be used when mounting to wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a water or gas line
may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.
AVERTISSEMENT
AVANT L’INSTALLATION DE CE PRODUIT, LES CONSIGNES D’INSTALLATION DOIVENT ÊTRE LUES ET PLEINEMENT COMPRISES.
CONSERVER CES CONSIGNES D’INSTALLATION DANS UN ENDROIT FACILEMENT ACCESSIBLE POUR RÉFÉRENCE FUTURE.
LA PROCÉDURE D’INSTALLATION CORRECTE PAR UN TECHNICIEN QUALIFIÉ DOIT ÊTRE OBSERVÉE, COMME DÉCRIT DANS
CES CONSIGNES D’INSTALLATION. FAUTE DE QUOI DES DOMMAGES MATÉRIELS, BLESSURES GRAVES, VOIRE MÊME LA MORT
PEUT SUBVENIR.
DES MESURES DE SÉCURITÉ DOIVENT ÊTRE PRATIQUÉES À TOUT MOMENT DURANT L’ASSEMBLAGE DE CE PRODUIT.
UTILISER L’ÉQUIPEMENT ET OUTILS DE SÉCURITÉ APPROPRIÉ POUR LA PROCÉDURE D’ASSEMBLAGE AFIN D’ÉVITER DES
BLESSURES.
LES SUPPORTS PREMIER MOUNTS NE GARANTISSENT PAS CONTRE LES DOMMAGES CAUSÉS PAR L’USAGE DU PRODUIT
DE MONTAGE PREMIER MOUNTS À D’AUTRES FINS QUE CELLES POUR LESQUELLES IL A ÉTÉ CONÇU OU DES DOMMAGES
CAUSÉS PAR DES ACCESSOIRES OU DES MODIFICATIONS NON AUTORISÉS, ET NOUS NE POUVONS PAS ÊTRE TENUS
RESPONSABLES DES DOMMAGES, PLAINTES, RÉCLAMATIONS, POURSUITES, ACTIONS OU CAUSES D’ACTION DE N’IMPORTE
QUELLE MANIÈRE RÉSULTANT DE, DÉCOULANT DE OU TOUCHANT DE N’IMPORTE QUELLE MANIÈRE UN TEL USAGE,
ACCESSOIRE OU MODIFICATION
Au moins deux pe s
matériels dû à la chute ou à la manipulation incorrecte de l’écran plat.
Si le montage s’effectue sur des rivets, assurez-vous que les vis de montage sont ancrées au centre des rivets. L’usage d’un détecteur de
rivet bord-à-bord est recommandé.
Il est recommandé qu’un maximum de plaque-plâtre de 5/8" soit utilisé lors d’un montage sur des rivets à bois.
Familiarisez-vous avec l’environnement de montage. Si un perçage et/ou une coupe est opéré sur la surface de montage, assurez-vous
S’assurer qu’il n’y a pas de canalisation d’eau ou de gaz naturel dans le mur où le montage doit être localisé. Une coupe ou un perçage
dans une canalisation d’eau ou de gaz naturel peut causer des dommages matériels ou des blessures graves.
Ce produit n’est destiné qu’à être utilisé à l’intérieur. L’utilisation de ce produit à l’extérieur pourrait entraîner des défauts matériels et/ou des
blessures graves.
Ne pas installer près de sources de forte chaleur. Ne pas installer sur une structure soumise aux vibrations, aux mouvements ou aux chocs.
Page 2
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
5/16” x 3” Lag Bolts
(Qty 4)
Thread Depth Indicator
(Qty 1)
Universal Spacers
(Qty 8)
Finned Anchor
(Qty 4)
5/16” Flat Washers
(Qty 4)
Universal Washers
(Qty 4)
Pencil Protective Eyewear
Electronic Stud Finder M6 or 1/4” Drill Bit 3/8” Masonary Drill Bit
Portable DrillPhillips Head Screwdriver Socket Wrench
13mm or 1/2” Socket
Level
M6 Safety Knob
(Qty 2)
M4 x 16mm (Qty 4)
M4 x 25mm (Qty 4)
M4 x 30mm (Qty 4)
M6 x 16mm (Qty 4)
M6 x 25mm (Qty 4)
M6 x 30mm (Qty 6)
M8 x 16mm (Qty 4)
M8 x 25mm (Qty 4)
M8 x 30mm (Qty 4)
Wall Mount
(Qty 1)
Bracket
(Qty 1 Pair)
Included Components
Required for installation
Panelock™
Hardware Kit M6 x 12mm
Security Head
Allen Wrench
x2 x1 x2
Page 3
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
2
3
1
XX
Wood Stud Installation
Introduction
XX
XX
Directional Mounting Arrow
The Directional Mounting Arrow stamped into the CTM-MS1 wall plate
indicates which edge is the top.
Mounting Safety
Two people are recommended for this step
Il est requis deux personnes pour cette étape.
You must secure the wall plate to two (2) wall studs with four (4) lag
bolts (2 lag bolts for each stud found).
1)
wall plate.
2) Use a pencil to mark each of the wall studs.
Vous devez assembler la sablière sur deux (2) rivets de mur avec un mini-
mum de quatre (4) tirefonds (2 tirefonds pour chaque rivet trouvé).
Minimum of 2 x 4 wood stud to be used
Minimum de 2 x 4 bois goujon pour être utilisé
Two people are recommended for this step; one person to level the wall
plate and another person to mark the wall stud location.
1) Place the wall plate against the wall in the desired viewing location.
2) Adjust the wall plate to align the mount slots in the wall plate with the
center of the wall studs.
3) Level the wall plate.
4) Use a pencil to mark the upper right mounting location along the center of
the wall stud.
Il est recommandé deux personnes pour cette étape : une personne
pour niveler la sablière et une autre personne pour marquer l’empla-
cement de l’ossature murale à claire-voie.
Drill a “pilot hole” in the center of the upper right mark using a 1/4” drill bit and
power drill.
Only use a 1/4" drill bit when drilling pilot holes.
N’utiliser qu’un foret de 1/4” lors du forage de guidage.
Page 4 premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
6
7
5
41) Place the wall plate against the wall and align it with the pilot hole.
2) Insert one (1) 5/16"x 3˝ lag bolt and one (1) 5/16" washer into the upper
right pilot hole.
3) Use a socket wrench and a 1/2" socket to tighten the lag bolt.
Do not overtighten the lag bolt.
Éviter de trop serrer les tirefonds.
1) Level the wall plate.
2) Use a pencil to mark the remaining three (3) mounting locations along the
center of each wall stud.
Two people are recommended for this step; one person to level the wall
plate and another person to drill the pilot holes.
Drill a “pilot hole” in the center of each of the marks with a power drill and a
1/4" drill bit.
Only use 1/4" drill bit when drilling the pilot holes.
Il est recommandé deux personnes pour cette étape : une personne
pour niveler la sablière et une autre personne pour percer le forage
de guidage.
N’utiliser qu’un foret de 1/4” lors du forage de guidage.
1) Insert one (1) 5/16” x 3″ lag bolt and one (1) 5/16” washer into each pilot hole
2) Tighten all lag bolts using a socket wrench and 1/2” socket.
Do not overtighten the lag bolts when attaching the mount to the wall.
Improper installation may result in personal injury or property damage.
mur. Une installation incorrecte peut entraîner des blessures ou des
dommages matériels.
XX
XX
XX
XX
Page 5
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
10
11
9
8
Concrete Installation
Two people are recommended for this step: one person to level the wall
plate and another person to mark the mounting locations.
Il est recommandé deux personnes pour cette étape : une personne pour
niveler la sablière et une autre personne pour marquer les emplacements
de montage.
Drill four (4) pilot holes of each mark using a drill and 3/8” masonary drill bit. Drill
3 inches deep.
Only use a 3/8" masonary drill bit when drilling pilot holes.
N’utiliser qu’un foret de 3/8” lors du forage de guidage.
Insert the Finned Anchors into each pilot hole.
Lightly tap each Finned Anchors into place with a hammer.
1) Insert one (1) 5/16” x 3” Lag Bolt and one (1) 5/16” washer into each
pilot hole.
2) Tighten all lag bolts using a socket wrench and 1/2” socket.
mur. Une installation incorrecte peut entraîner des blessures ou des
dommages matériels.
Do not overtighten the lag bolts when attaching the mount to the
wall. Improper installation may result in personal injury or property
damage.
Page 6 premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
1) Insert a small straw or toothpick into the threaded inserts found on the
2) Use a pencil to mark the depth of the threaded insert on the small straw
or toothpick.
3) Mark the straw or toothpick 1/8” above the depth of the threaded insert,
as shown in Figure 1.
4) Insert the small straw or toothpick into the remaining threaded inserts
to compare and verify their depth using the straw or toothpick’s 1/8”
allowance mark.
5) Locate the correct diameter screw for the threaded insert.
If the screw you selected is longer than the 1/8” allowance mark on
the small straw or toothpick, as shown in Figure 2 and Figure 3, do
not use this screw. The screw length must not bypass the mark.
6) Test each size of the screws provided.
The correct screws should thread easily into themounting point and
not pull out when tension is applied.
Small Straw or Toothpick
Marking the 1/8”
Allowance
Small Straw
or Toothpick Small Straw
or Toothpick Depth Plus 1/8” Allowance
Mark
Depth Plus 1/8” Allowance
Mark
Selecting the Mounting Hardware
Universal Washer Installation
Premier Mounts’ Universal Washers are designed to accommodate the
The Universal Washer must be installed between the head of
the mounting screw and the mounting bracket as shown.
M8
M6
M5
M4
Si la vis que vous sélectionnez est plus longue que la marque du
jeu maximal de 1/8” sur le paillon ou le cure-dents, comme illustré
sur le schéma 2 et le schéma 3, veuillez ne pas utiliser cette vis. La
longueur de la vis doit dévier la marque.
Page 7
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
Universal Spacer Installation
Attaching the Mounting Brackets to the Flat Panel
1)
2) Identify the number and location of the thread inserts on the back of your
3) Aligning the holes on each mounting bracket with the thread inserts on the
4)
two (2) screws per bracket.
Do not over tighten the mounting hardware.
Éviter de trop serrer le dispositif de montage.
Flat Panel
Universal Washer
Universal Spacer
Mounting Bracket
Mount Point
Mounting Screw
Page 8
Premier Mounts’ Universal Spacers allow you to attach the mounting bracket
panel.
The Universal Spacers must be stacked and oriented as shown.
The Universal Spacers must only be installed between the mounting
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
CTM-MS1
Attaching the Flat-Panel to the Mount
Safety Knurl Knob Installation
This section requires two people.
hooks of both mounting brackets are securely seated on the upper and
lower mounting rails of the wall panel.
1)
panel.
2)
3) Engage the top and bottom mounting brackets to the rails of the wall plate.
Cette section exige deux personnes.
Éviter de relâcher votre écran plat jusqu’à ce que vous vous assuriez que
les crochets de haut et de bas de tous les deux supports de montage sont
bien posés sur les rails de montage hauts et bas de la sablière.
dislodged from the CTM-MS1.
1)
2) Install and tighten a safety knurl knob at the top of one of the mounting
brackets.
3) Repeat step 2 for the other safety knurl knob.
If you chose not to install the safety knurl knobs and instead chose to
use the Panelock, skip this section and proceed to the Panelock
Installation section below.
The Panelock is a theft deterrent device. It comes with security hardware
that requires a special tool that is used to install and remove the security
head screws.
Les boutons de molette de sécurité maintiennent le panneau plat d'être
accidentellement délogé du CTM-MS1.
Safety Knurl Knob
(1 per Bracket)
Page 9
premiermounts.com | p. 800.368.9700 | e. [email protected]
Panelock™ Installation
Locking Safety Screw Installation
Tilt Adjustment
If the safety knurl knobs were previously installed, they must be
removed prior to installing the Panelock™ hardware.
1) Slide the Panelock™ onto the top mounting rail, placing the Panelock™ to
Be sure that the Panelock™ is facing in the same direction as shown in
the illustration to the right.
2) Insert and tighten one (1) M6 x 12mm screw to attach the Panelock™ to
Repeat steps 1 and 2 to attach the remaining Panelock™.
Panelock
Security
Head Wrench
M6 x 12mm
Security
Panelock
Security Head
Wrench
dislodged from the CTM-MS1.
1) Thread an M6 x 30mm locking safety screw at the bottom of one of the
mounting brackets.
2) Use a Phillips head screwdriver to tighten the locking safety screw.
3) Repeat 1 and 2 for the other locking safety screw.
Do not overtighten the locking safety screws.
Éviter de trop serrer les vis de blocage.
Les boutons de molette de sécurité maintiennent le panneau plat d'être
accidentellement délogé du CTM-MS1.
Adjusting the Flat Panel Friction Tilt Angle
1)
2)
3)
you.
Adjusting the Flat Panel to the Original Position
1)
2)
3)
wall.
Installation Guide
CTM-MS1
M6 x 30mm
Locking Safety Screw
(1 per Bracket)
Page 10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Premier Mounts CTM-MS1 Mode d'emploi

Catégorie
Supports muraux à panneau plat
Taper
Mode d'emploi

dans d''autres langues