2
EATON IL520003EN Installation Instructions
Installation Instructions - LDSQA4 Commercial Recessed Adjustable LED
2
INSTALLATION
Rough-In Section
1. Fixture Attachment Method: Install fixture into ceiling
cavity using 1/2˝ electrical conduit. Use 3/4˝ channel,
1-1/2˝ channel, 1/8˝ x 1/2˝ bar stock, or T-bar fasteners
as mounting rails (furnished by others) by inserting
them through hanger brackets at both sides.
2. Adjust hanger adjustment screws so bottom of collar
is flush with finished ceiling line. Hanger bracket is
reversible for total adjustment of 5˝ (Figure 2).
3. Remove one of the junction box covers. Connect supply
lead wires to lead wires of driver as per Wiring Diagram
and in accordance with your local electrical code(s) or
N.E.C.
Optic Installation
1. Remove Optic from protective packaging and remove
rubber Media Holder (Optional) ring to install any
optional Media (Figure 5). To re-attach Media Holder
to Reflector start with Alignment Arrow at Alignment
Notch and work around flange. For 1 piece of Media
(optional) place the Reflector in the upper position
(Figure 6 & 7) and for 2 pieces of Media (optional) place
the Reflector in the lower position (Figure 6 & 7).
2. When using directional media such as the Linear
Spread Lens (optional) align the lens grooves with
Alignment Arrow on Media Holder (Figure 8).
3. Remove protective LED Cover (Figure 9) from Housing
by rotating counter clockwise.
4. Insert Optic Assembly into housing Flange first while
holding the metal Reflector and not the rubber Media
Holder. Place the Flange on the white Reflector
Mounting Clip and press firmly then rotate clockwise
until the 3 latches snap into place (Figure 10). Ensure
Alignment Arrows on Media Holder and Reflector
Mounting Clip line up for optional directional media
(Figure 11).
Hanger Adjustment
Screws
Collar
Finished
Ceiling Line
Rotation
Thumb Screw
Collar Locking
Thumb Nut
Figure 2.
Figure 3.
Figure 4.
Angle
Adjustment
Plunger
Angle Adjustment
Thumbnut
Angle
Alignment
Marks
Rotation and Tilt Adjustment
1. Loosen Angle Adjustment Thumbnuts (2) through collar
opening but do not remove (Figure 3).
2. Pull Angle adjustment plunger to change tilt and release
for rough adjustment in 10 degree increments. Angle
alignment marks provided for reference (Figure 3).
2. Twist angle adjustment plunger counterclockwise while
pulled out to lock in place. For full adjustment between
0 degrees and max tilt.
3. Tighten Angle Adjustment Thumbnuts (2) to lock in
angle.
5. If adjustment of the rotational alignment of the collar is
desired, loosen the collar locking thumb nut. Rotate the
collar to the desired position and then tighten the collar
locking thumb nut (Figure 4)
6. Reach through collar opening, loosen Rotation Thumb
Screw, rotate to desired direction and re tighten thumb
screw to lock in place (Figure 4).