Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to
follow these instructions could result in property damage, bodily injury, or even death.
Contact your local building or re ofcials about restrictions and installation inspection in your area.
Save these instructions.
United States Stove Company
227 Industrial Park
South Pittsburg, TN 37380
www.USSTOVE.com
PHONE: 800-750-2723
Owner’s Manual
Model 5520
Golden
Eagle
Certied for installations in the USA and Canada
This unit is not intended to be used as a
primary source of heat.
U.S. Environmental Protection Agency
Certied to comply with 2015 particulate
emissions standards.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is know to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des produits chimiques, y compris le
monoxyde de carbone, qui est connu dans l'État de Californie pour causer
le cancer, des malformations congénitales et / ou d'autres problèmes de
reproduction. Pour plus d'informations, visitez www.P65warnings.ca.gov
-2-
This manual describes the installation and operation of the Golden Eagle, 5520 wood heater. This heater meets
the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15,
2015. Under specic test conditions this heater has been shown to deliver heat at rates ranging from 8,211 to
34,039 Btu/hr.
IMPORTANT: Read this entire manual before
installing and operating this product. Failure to do
so may result in property damage, bodily injury,
or even death. Proper installation of this stove is
crucial for safe and efcient operation.
Install vent at clearances specied by the vent
manufacturer.
If a chimney or creosote re occurs, press the “OFF”
button immediately. Do not unplug the unit.
Do not connect the pellet vent to a vent serving
any other appliance or stove.
Do not install a ue damper in the exhaust venting
system of this unit.
Use of outside air is not required for this unit.
Contact your local building ofcials to obtain
a permit and information on any additional
installation restrictions or inspection requirements in
your area.
Do not throw this manual away. This manual has
important operating and maintenance instructions
that you will need at a later time. Always follow the
instructions in this manual.
This appliance is designed for the use of pelletized
fuel that meet or exceed the standard set by the
Pellet Fuel Institute(PFI). The use of other fuels will
void warranty.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter uid, or similar liquids to
start or ‘freshen up’ a re in this stove. Keep all such
liquids well away from the stove while it is in use.
A working smoke detector must be installed in the
same room as this product.
Do not unplug the stove if you suspect a
malfunction. Turn the ON/OFF SWITCH to ‘OFF’ and
contact your dealer.
Your stove requires periodic maintenance and
cleaning (see “MAINTENANCE ”). Failure to
maintain your stove may lead to improper and/or
unsafe operation.
Disconnect the power cord before performing any
maintenance! NOTE: Turning the ON/OFF Switch
to “OFF” does not disconnect all power to the
electrical components of the stove.
Never try to repair or replace any part of the
stove unless instructions for doing so are given in
this manual. All other work should be done by a
trained technician.
Do not operate your stove with the viewing door
open. The auger will not feed pellets under these
circumstances and a safety concern may arise
from sparks or fumes entering the room.
Allow the stove to cool before performing any
maintenance or cleaning. Ashes must be disposed
in a metal container with a tight tting lid. The
closed container of ashes should be placed on a
non-combustible surface or on the ground, well
away from all combustible materials, pending nal
disposal.
The exhaust system should be checked monthly
during the burning season for any build-up of soot
or creosote.
Do not touch the hot surfaces of the stove.
Educate all children on the dangers of a high-
temperature stove. Young children should be
supervised when they are in the same room as the
stove.
The hopper and stove top will be hot during
operation; therefore, you should always use some
type of hand protection when refueling your stove.
A power surge protector is required. This unit must
be plugged into a 110 - 120V, 60 Hz grounded
electrical outlet. Do not use an adapter plug
or sever the grounding plug. Do not route the
electrical cord underneath, in front of, or over the
heater. Do not route the cord in foot trafc areas
or pinch the cord under furniture. Do not plug into
a GFI outlet.
The heater will not operate during a power outage.
If a power outage does occur, check the heater
for smoke spillage and open a window if any
smoke spills into the room.
The feed door must be closed and sealed during
operation.
Never block free airow through the open vents of
the unit.
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled by high
torque electric motors. Keep all body parts away
from the auger while the stove is plugged into an
electrical outlet. These moving parts may begin to
move at any time while the stove is plugged in.
Do not place clothing or other ammable items on
or near this stove.
When installed in a mobile home, the stove must
be grounded directly to the steel chassis and
bolted to the oor. WARNING—THIS UNIT MUST
NOT BE INSTALLED IN THE BEDROOM (per HUD
requirements). CAUTION—The structural integrity of
the mobile home oor, wall, and ceiling/roof must
be maintained.
This appliance is not intended for commercial use.
* This appliance is a freestanding heater. It is not intended to be attached to any type of ducting. It is not a
furnace.
Safety Precautions
-3-
Heating Specications
Fuel Burn Rate* (lowest setting) 1.0 lbs./hr. (0.5 kg/hr)
Burn Time (lowest setting) 120 hrs. (approximate)
Hopper Capacity 120 lbs. (55kg)
Dimensions
Height 34 in. (864mm)
Width 26 in. (660mm)
Depth 27 in. (686mm)
Weight 210 lbs. (95.5kg)
Electrical Specications
Electrical Rating 110-120 volts, 60 HZ, 3.0 Amps
Watts (operational) 175 (approx.)
Watts (igniter running) 425 (approx.)
VISIBLE SMOKE
The amount of visible smoke being produced can be an effective method of determining how efciently the
combustion process is taking place at the given settings. Visible smoke consist of unburned fuel and moisture
leaving your stove. Learn to adjust the air settings of your specic unit to produce the smallest amount of visible
smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess
visible smoke and burn poorly.
FUEL CONSIDERATIONS
Your pellet stove is designed to burn premium hardwood pellets that comply with Association of Pellet Fuel
Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”,
not less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per
million). Pellets that are soft, contain excessive amounts of loose sawdust, have been, or are wet will result in
reduced performance.
Store your pellets in a dry place. DO NOT store the fuel within the installation clearances of the unit or within the
space required for refueling and ash removal. Doing so could result in a house re.
SAFETY AND EPA COMPLIANCE
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a
manufactured or mobile home. It has been safety tested and listed to ASTM E 1509-04, ULC-S627-00, ULC/ORD
C1482-90, and(UM) 84-HUD by INTERTEK Testing Services in Fairview, Oregon USA.
* Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%.
Use PFI listed fuel for best results.
Specications
-4-
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result in
property damage, bodily injury, or even death!
(See specic installation details for clearances and other installation requirements)
A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove installation.
An Alcove Unit—supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE HOME
REQUIREMENTS). The installation must comply with the Manufactured Home and Safety Standard (HUD), CFR3280,
Part 24.
It is recommended that only a authorized technician install your pellet stove, preferably an NFI certied specialist.
CAUTION: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS
SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
FLOOR PROTECTION
This unit must be installed on a 1/2” thick, non-combustible oor protector with a k-value of 0.42. A 1” thick
protector with a k-value of 0.84 is also acceptable. The oor protector should be large enough to extend a
minimum of 6 in. (152.4mm) in front, 6 in. (152.4mm) on each side, and 1 in. (25.4mm) behind the stove.
Floor protection must extend under and 2 in. (50.8mm) to each side of the chimney tee for an interior vertical
installation. Your pellet stove will need a minimum 31” (787mm) x 38” (965mm) oor protector.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
Installation
-5-
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications
in accordance with the clearances given in FIGURES 3-5 and TABLE 1. Any reduction in clearance to combustibles
may only be done by means approved by a regulatory authority.
NOTE: Distance “C” on the left-hand side of your pellet stove may need to be greater than the minimum
required clearance for suitable access to the control panel.
FIGURE 3
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
FIGURE 4
SIDEWALL CLEARANCES
CORNER INSTALLATION
FIGURE 5
ALCOVE CLEARANCES
PARALLEL
A - Backwall to unit 3.00” 76mm
B - Sidewall to ue 16.00” 406mm
C - Sidewall to top edge of unit 12.00” 305mm
CORNER
ALCOVE
D - Adjacent wall to unit 1.00” 25.4mm
E - Alcove depth 36.00” 914mm
F - Alcove height 60.00” 1520mm
TABLE 1
CLEARANCES
Installation
-6-
VENTING REQUIREMENTS
Install vent at clearances specied by the vent manufacturer.
Do not connect the pellet vent to a vent serving any other appliance or stove.
Do not install a ue damper in the exhaust venting system of this unit.
The following installation guidelines must be followed to ensure conformity with both the safety listing of this
stove and to local building codes. Do not use makeshift methods or compromise in the installation.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical pipe outside the home. This will create some natural draft to
reduce the possibility of smoke or odor during appliance shutdown and keep exhaust from causing a nuisance
or hazard by exposing people or shrubs to high temperatures. The maximum recommend vertical venting height
is 12-feet for 3-inch type “PL” vent. Total length of horizontal vent must not exceed 4-feet. This could cause back
pressure. Use no more than 180 degrees of elbows (two 90-degree elbows, or two 45-degree and one 90-degree
elbow, etc.) to maintain adequate draft.
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too
much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpufng into
the room and ‘plugging’ of the chimney.
Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney
connector joints.
An uncontrollable burn or excessive temperature indicates excessive draft.
Take into account the chimney’s location to insure it is not too close to neighbors or in a valley which may cause
unhealthy or nuisance conditions.
PELLET VENT TYPE
A UL listed 3-inch or 4-inch type “PL” pellet vent exhaust system must be used for installation and attached to the
pipe connector provided on the back of the stove (use a 3-inch to 4-inch adapter for 4-inch pipe). Connection
at back of stove must be sealed using Hi-Temp RTV. Use 4-inch vent if the vent height is over 12-feet or if the
installation is over 2,500 feet above sea level.
We recommend the use of Simpson Dura-Vent® or Metal-Fab® pipe (if you use other pipe, consult your local
building codes and/or building inspectors). Do not use Type-B Gas Vent pipe or galvanized pipe with this unit. The
pellet vent pipe is designed to disassemble for cleaning and should be checked several times during the burning
season. Pellet vent pipe is not furnished with the unit and must be purchased separately.
PELLET VENT INSTALLATION
The installation must include a clean-out tee to enable collection of y ash and to permit periodic cleaning
of the exhaust system. The clean-out tee must be installed at the base of the vertical section, not in horizontal
section. 90-degree elbows accumulate y ash and soot thereby, reducing exhaust ow and performance of the
stove. Each elbow or tee reduces draft potential by 30% to 50%.
All joints in the vent system must be fastened by at least 3 screws, and all joints must be sealed with Hi-Temp RTV
silicone sealant on the inside and high temperature tape on the outside to be airtight. The area where the vent
pipe penetrates to the exterior of the home must be sealed with silicone or other means to maintain the vapor
barrier between the exterior and the interior of the home. Vent surfaces can get hot enough to cause burns if
touched by children. Noncombustible shielding or guards may be required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-enclosed area, such as; carport, garage, attic, crawl space,
under a sundeck or porch, narrow walkway, or any other location that can build up a concentration of fumes.
The termination must exhaust above the outside air inlet elevation. The termination must not be located where it
will become plugged by snow or other materials. Do not terminate the venting into an existing steel or masonry
chimney.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
Installation
-7-
G
VENT TERMINATION CLEARANCES
A. Minimum 4-feet (1.22m) clearance below or beside any door or window that opens.
B. Minimum 1-foot (0.3m) clearance above any door or window that opens.
C. Minimum 3-feet (0.91m) clearance from any adjacent building.
D. Minimum 7-feet (2.13m) clearance from any grade when adjacent to public walkways.
E. Minimum 2-feet (0.61m) clearance above any grass, plants, or other combustible materials.
F. Minimum 3-feet (0.91m) clearance from an forced air intake of any appliance.
G. Minimum 2-feet (0.61m) clearance below eves or overhang.
H. Minimum 1-foot (0.3m) clearance horizontally from combustible wall.
I. Must be a minimum of 3 feet (0.91m) above the roof and 2 feet (0.61m) above the highest point or the roof
within 10 feet (3.05m).
FIGURE 6
VENT TERMINATION CLEARANCES
Installation
-8-
THROUGH THE WALL INSTALLATION (RECOMMENDED
INSTALLATION)
Canadian installations must conform to CAN/CSA-B365.
To vent the unit through the wall, connect the pipe
adapter to the exhaust motor adapter. If the exhaust
adapter is at least 18 in.(457mm) above ground level, a
straight section of pellet vent pipe can be used through
the wall.
Your heater dealer should be able to provide you with
a kit that will handle most of this installation, which will
include a wall thimble that will allow the proper clearance
through a combustible wall. Once outside the structure,
a 3 in.(76mm) clearance should be maintained from the
outside wall and a clean out tee should be placed on
the pipe with a 90-degree turn away from the house. At
this point, a 3ft (0.91m) (minimum) section of pipe should
be added with a horizontal cap, which would complete
the installation (see FIGURE 7).
A support bracket should be placed just below the
termination cap or one every 4ft (1.22m) to make the
system more stable. If you live in an area that has heavy
snowfall, it is recommended that the installation be taller
than 3ft (0.91m) to get above the snowdrift line. This
same installation can be used if your heater is below
ground level by simply adding the clean-out section and
vertical pipe inside until ground level is reached. With
this installation you have to be aware of the snowdrift
line, dead grass, and leaves. We require a 3ft (0.91m)
minimum vertical rise on the inside or outside of the house.
The “through the wall” installation is the least expensive and simplest installation. Never terminate the end vent
under a deck, in an alcove, under a window, or between two windows. We recommend Simpson Dura-Vent®
or Metal-Fab® kits.
THROUGH THE ROOF/CEILING INSTALLATION
When venting the heater through the ceiling, the pipe is connected the same as through the wall, except the
clean-out tee is always on the inside of the house, and a 3 in.(76mm) adapter is added before the clean-out tee.
You must use the proper ceiling support anges and roof ashing (supplied by the pipe manufacturer; follow the
pipe manufacturer’s directions). It is important to note that if your vertical run of pipe is more than 12ft (3.66m),
the pellet vent pipe size should be increased to 4 in. (102mm) in diameter.
Do not exceed more than 4ft (1.22m) of pipe on a horizontal run and use as few elbows as possible. If an offset
is required, it is better to install 45-degree elbows rather than 90-degree elbows.
FIGURE 7
TYPICAL THROUGH THE WALL INSTALLATION
Installation
-9-
NOTE: Dimensions from the oor to your
stoves inlet/exhaust pipes are approximate
and may vary depending on your
installation.
FIGURE 9
TYPICAL FRESH AIR TERMINATION
FIGURE 8
EXHAUST/INLET LOCATIONS
OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME) OR AN AIRTIGHT HOME
Depending on your location and home construction, outside air may be necessary for optimal performance.
Metal pipe (solid or exible) must be used for the outside air installation. PVC pipe is NOT approved and should
NEVER be used.
A wind shield over the termination of the outside air pipe or a 90-degree elbow or bend away from the prevailing
winds MUST be used when an outside air pipe is installed through the side of a building. The outside air termination
MUST be at least 1ft (0.305m) away from the exhaust system termination.
The outside air pipe on your heater is 2” (50.8mm) OD. The outside air connecting pipe must be at least 2”
(50.8mm) ID. The outside air connection used MUST NOT restrict the amount of air available to your heater. The
outside air connecting pipe must be as short and free of bends as possible, and it must t over, not inside, the
outside air connection to the heater.
SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - Do not install in a sleeping room
CAUTION! - The structural integrity of the mobile home oor, wall, and ceiling/roof must be maintained.
A working smoke detector must be installed in the same room as this product.
It must be installed at least 15 feet (4,57 m) from the appliance in order to prevent undue triggering of the
detector when reloading.
In addition to the previously detailed installation requirements, mobile home installations must meet the following
requirements:
The heater must be permanently bolted to the oor through provided holes in the base.
The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire
using a serrated or star washer to penetrate paint or protective coating to ensure grounding.
Vent must be 3 or 4-inch “PL” Vent and must extend a minimum or 36 in.(914mm) above the roof line of the
mobile home and must be installed using a UL listed ceiling re stop and rain cap.
When moving your mobile home, all exterior venting must be removed while the mobile home is being
relocated. After relocation, all venting must be reinstalled and securely fastened.
Outside Air is mandatory for mobile home installation. See your dealer for purchasing or call customer
service.
Check with your local building ofcials as other codes may apply.
Installation
-10-
PANEL CONTROLS
The blowers and automatic fuel supply are controlled from a panel on the left
side of the appliance. The control panel functions are as follows:
A. ON/OFF SWITCH
When pushed the stove will automatically ignite. No other restarter is
necessary. The igniter will stay on for at least 10 and up to 15 minutes,
depending on when Proof of Fire is reached. The re should start in about 5
minutes.
the green light located above the On/Off button (in the On/Off box) will ash
during the ignition start-up period.
The Heat Level Advance is inoperable during the ignition start period. When
the green light continuously stays on, the Heat Level Advance can be
adjusted to achieve the desired heat output.
To manually ignite in case of ignitor failure. Place a handful of pellets in the burnpot.
Add starter gel for pellet stoves, ignite, close door, turn the unit on.. Replace the
ignitor as soon as possible.
NOTE: If the stove has been shut off, and you want to re-start it while it is still warm,
the “on/off” button must be held down for 2 seconds.
B. B. FUEL FEED SWITCH
When the “Fuel Feed” button is pushed and held down, the stove will feed
pellets continuously into the burn pot.
While the stove’s auger system is feeding pellets, the green light (in the “Fuel
Feed” box) will be on.
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT
COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION.
C. HIGH FAN SWITCH
The room air fan speed varies directly with the feed rate. The “HIGH FAN”
switch overrides this variable speed function. It will set the room air blower
speed to high at any feed rate setting.
When the “HIGH FAN” button is pushed, the room air fan will switch to its highest setting.
When this button is pushed again, the room air fan will return to its original setting based on the Heat Level
Advance setting.
D. RESET TRIM
Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Heat Level Advance
bar graph. This is usually a one-time adjustment based on the fuel you are using. The “RESET TRIM” button when
adjusted will allow for 3 different feed rate settings for the #1 feed setting only. To adjust simply push the “RESET
TRIM” button while the stove is operating at setting “1” and watch the bar graph.
When the “1” & “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting.
(Approx. 0.9 pounds per hour)
When the “1” light is illuminated on the bar graph, the low feed rate is at its “normal” setting.
When the “1” & “4” lights are illuminated on the bar graph, the low feed rate is at its “highest” setting.
NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Heat Level Advance bar graph.
For example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will
be illuminated on the bar graph.
E. HEAT LEVEL ADVANCE
This button, when pushed, will set the pellet feed rate, hence the heat output of your stove. The levels of
heat output will incrementally change on the bar graph starting from level “1” to “4”.
NOTE: When dropping 3 or more heat level settings (4 to 1,) push the ‘High Fan’ button and allow the room air
fan to run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the
high temp thermodisc does trip, see “SAFETY FEATURES”.
Control Panel
-11-
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE - Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter uid, or similar liquids to start or “freshen up” a re in this stove. Keep all such
liquids well away from the stove while it is in use.
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKINS
BURNS.
DO NOT USE GRATES OR ELEVATE THE FIRE. BUILD FIRE DIRECTLY ON HEARTH.
DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
This heater is designed to burn only PFI Premium grade pellets. This appliance can also burn pellets rated as
standard after May 16, 2015
DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners,
or asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt water
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or
particleboard. The prohibition against burning
these materials does not prohibit the use of re
starters made from paper, cardboard, saw dust,
wax and similar substances for the purpose of
starting a re in an affected wood heater.
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
PROPER FUEL
THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those 1/4”
or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger ights, which
prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building
codes for which the stove has been approved and will void all warranties. The design incorporates automatic
feed of the pellet fuel into the re at a carefully prescribed rate. Any additional fuel introduced by hand will not
increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do
not burn wet pellets. The stove’s performance depends heavily on the quality of your pellet fuel. Avoid pellet
brands that display these characteristics:
a. Excess Fines “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand.
Pellets can be screened before being placed in hopper to remove most nes.
b. Binders – Some pellets are produced with materials to hold the together or “bind” them.
c. High ash content Poor quality pellets will often create smoke and dirty glass. They will create a need for
more frequent maintenance. You will have to empty the burn pot plus vacuum the entire system more
often. Poor quality pellets could damage the auger. United States Stove Co. cannot accept responsibility
for damage due to poor quality pellets.
Operation
-12-
Primary Air Settings
(Slide Damper is located on the left side of the stove)
(Damper Adjustment: Pulling out on damper increases air)
Low Heat setting 1, air slide fully closed
Medium - Low Heat setting 2, air slide set at 0.365” from full closed
Medium - High Heat setting 3, air slide set at 1” from full closed
High Heat setting 4, air slide fully open
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none of the air holes are plugged. Clean the rebox, and then
reinstall burn pot. Clean door glass, if necessary (a dry cloth or paper towel is usually sufcient). Never use abrasive
cleaners on the glass or door. Check fuel in the hopper, and rell if necessary.
NOTE: The 5520 Hopper can hold up to 120 lbs. of pellets.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel. Use only the burn pot supplied with this heater.
Hopper lid must be closed in order for the unit to feed pellets. If it is the rst time you have started the unit, or
anytime the hopper has been emptied of pellets, it will be necessary to prime the auger. In order to prime the
auger press and hold the fuel feed button after starting the unit. Keep fuel feed button depressed until pellets
begin to fall into the burn pot, then release the fuel feed button and allow the unit to operate normally.
During the start up period:
1. DO NOT open the viewing door.
2. DO NOT open the damper more than 1/4”.
3. DO NOT add pellets to the burn pot by hand.
4. DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets). A dangerous
condition could result.
NOTE: During the rst few res, your stove will emit an odor as the high temperature paint cures or becomes
seasoned to the metal. Maintaining smaller res will minimize this. Avoid placing items on stove top during this
period because paint could be affected.
THE AUTOMATIC FIRESTARTER
a. Fill hopper and clean burn pot.
b. Press “On/Off” button. Make sure light is on.
c. The damper should be completely closed or open no more than 1/4” during start-up. This will vary depending
on your installation and elevation. Once re is established adjust for desired ame increasing the amount the
damper is open as the heat setting is increased. (See “DAMPER CONTROL”)
d. Adjust feed rate to desired setting by pressing “Heat Level Advance” button.
If re doesn’t start in 15 minutes, press “On/Off”, wait a few minutes, clear the burn pot, and start procedure
again.
DAMPER CONTROL
The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to
the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you
to improve the efciency of your stove. Providing correct combustion air will reduce the frequency of cleaning
your glass door and prevent the rapid buildup of creosote inside your stove and chimney.
You should adjust the damper based on the re’s appearance. A low, reddish, dirty re can be improved by
pulling the damper out slightly. A “blow torch” re can be improved by pushing the damper in a bit.
As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper
should be more open. Through trial and error, you will nd the best setting. Consult your dealer if you need help.
NOTE: On “1”, damper should be either completely closed or out approximately 1/8” to 1/4”. If damper is out
too far, it can cause the re to go out.
OPENING DOOR
If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut
down. If the stove shuts down push the “On/Off” button to re-start your stove.
Operation
-13-
ROOM AIR FAN
When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This
usually takes about 10 minutes from start-up.
RE-STARTING A WARM STOVE
If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held
down for 2 seconds.
IF STOVE RUNS OUT OF PELLETS
The re goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.
After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes. After the
10 minutes the “3” light on the bar graph will ash and the “On/Off” light will go off. To restart, rell hopper and
press “Fuel Feed” button until pellets begin to fall into burn pot. Press “On/Off” button.
REFUELING
The hopper and stove top will be hot during operation; therefore, you should always use some type of hand
protection when refueling your stove.
Never place your hand near the auger while the stove is in operation.
We recommend that you not let the hopper drop below ¼ full.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.
SHUTDOWN PROCEDURE
Turning your stove off is a matter of pressing the “On/Off” control panel switch. The red light will go out. The
blowers will continue to operate until internal rebox temperatures have fallen to a preset level.
SAFETY FEATURES
a. Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.
1. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
2. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut
down the auger, preventing the stove from overheating.
NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem.
A service call may be required.
b. If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. Close the door and press “On/Off” button to continue operation
of your stove.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
WARNING: Never shut down this unit by unplugging it from the power source.
Operation
-14-
OPTIONAL THERMOSTAT
A optional thermostat may help you maintain a constant
house temperature automatically. A millivolt thermostat is
required. A xed wall mount or hand held model can be
used. The control panel can be set up two ways to operate
your stove in thermostat mode.
THERMOSTAT INSTALLATION
A MILLIVOLT NON-PROGRAMMABLE THERMOSTAT IS
REQUIRED.
Unplug stove from power outlet.
Remove control board from stove.
The two thermostat wires connect to the terminal block
on the lower left side of the back of the control board.
Insert the wires in the terminal side and tighten the two
screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE
MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE
STOVE RESTARTED.
MANUAL MODE
USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT
AN OPTIONAL THERMOSTAT.
In this mode the stove will operate only from the control
panel as detailed in the “OPERATION” section of this
owner’s manual.
HIGH/LOW THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT.
When engaged in this mode the stove will
automatically switch between two settings. When
warm enough, it will switch to the #1 or low setting. The
room air blower will also slow to its lowest speed.
The Heat Level Advance setting on the bar graph will
stay where it was initially set. When the house cools
below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.
ON/OFF THERMOSTAT MODE (IGNITOR LIFE WILL BE CUT DOWN IN THIS MODE)
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT.
In this mode, when the home is warm enough the stove will shut off. The fans will continue to run until the
stove cools.
When the home cools below the thermostat setting, the stove will automatically restart and run at the last
feed rate setting.
NOTE: When in “high/low” or “on/off” thermostat mode –
Do not operate the stove higher than the #3 setting.
Set damper control rod approximately 1/4” to 1/2” out. This will vary depending on elevation and weather
conditions. Observe stoves operation and adjust damper as necessary.
Thermostat Installation
On/Off High/Low Manual
-15-
Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.
Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any
inspection, cleaning, or maintenance work.
Never perform any inspections, cleaning, or maintenance on a hot stove.
Do not operate stove with broken glass , leakage of ue gas may result.
WARNING THE CHIMNEY AND CHIMNEY CONNECTOR MUST BE KEPT IN GOOD CONDITION AND CLEAN.
EXHAUST SYSTEM
Creosote Formation When any wood is burned slowly, it produces tar and other organic vapors, which combine
with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney ue or a
newly started re or from a slow-burning re. As a result, creosote residue accumulates on the ue lining. When
ignited, this creosote makes an extremely hot re, which may damage the chimney or even destroy the house.
Despite their high efciency, pellet stoves can accumulate creosote under certain conditions.
Soot and Flyash: Formation and Need for Removal- The products of combustion will contain small particles of
yash. The yash will collect in the exhaust venting system and restrict the ow of the ue gases. Incomplete
combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some
soot formation which will collect in the exhaust venting system. The exhaust venting system should B e inspected
at least once every year to determine if cleaning is necessary.
Inspection and Removal The chimney connector and chimney should be inspected annually or per ton of
pellets to determine if creosote or y ash build-up has occurred. If creosote has accumulated, it should be
removed to reduce the risk of a chimney re. Inspect the system at the stove connection and at the chimney
top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top
as well as from the bottom. The creosote should be removed with a brush specically designed for the type of
chimney in use. A qualied chimney sweep can perform this service. It is also recommended that before each
heating season the entire system be professionally inspected, cleaned and, if necessary, repaired. To clean the
chimney, disconnect the vent from the stove.
INTERIOR CHAMBERS
Periodically remove and clean the burn pot and the area inside the burn pot housing. In particular it is advisable
to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn
pot freely. Remove the two(2) plates on each side of the burn pot housing and clean out that rear chamber.
If a vacuum is used to clean your stove, we suggest using a vacuum designed for ash removal. Some regular
vacuum cleaner (i.e. shop vacs) may leak ash into the room.
ASH DISPOSAL
Ashes should be placed in a metal container with a tight tting lid. The closed container of ashes should be
placed on a noncombustible oor or on the ground, well away from all combustible materials, pending nal
disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the
closed container until all cinders have been thoroughly cooled. The container shall not be used for other trash or
waste disposal.
SMOKE AND CO MONITORS
Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods of time. While the modern combustion systems in
heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or conned
areas can be dangerous. Make sure you stove gaskets and chimney joints are in good working order and sealing
properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas
having the potential to generate CO.
CHECK AND CLEAN THE HOPPER
Check the hopper periodically to determine if there is any sawdust or pellets that are sticking to the hopper
surface. Clean as needed.
DOOR AND GLASS GASKETS
Inspect the main door and glass window gaskets periodically. The main door may need to be removed to have
frayed, broken, or compacted gaskets replaced by your authorized dealer. The glass gasket has a gap at the
bottom for the air wash. This unit’s door uses a 3/4” diameter rope gasket.
Maintenance
-16-
BLOWER MOTORS
Clean the air holes on the motors of both the exhaust and distribution blowers annually. Remove the exhaust
blower from the exhaust duct and clean out the internal fan blades and housing as part of your fall start-up.
PAINTED SURFACES
Painted surfaces may be wiped down with a damp cloth. If scratches appear, or you wish to renew your paint,
contact your authorized dealer to obtain a can of suitable high-temperature paint.
GLASS - CLEANING, REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
Cleaning - We recommend using a high quality glass cleaner. Should a build up of creosote or carbon
accumulate, you may wish to use 000 steel wool and water to clean the glass. DO NOT use abrasive cleaners.
DO NOT perform the cleaning while the glass is HOT. ,
In the event you need to replace the glass, remove the six(6) screws and glass retainers. While wearing leather
gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from
the door frame. Dispose of all broken glass properly. ONLY high temperature ceramic glass of the correct size and
thickness may be used. DO NOT substitute alternative materials for the glass. Contact your authorized dealer to
obtain this glass. Re-install the new glass by re-attaching the retainers and screws, careful not to overtighten the
screws for this could damage the glass.
DO NOT abuse the door glass by striking, slamming or similar trauma. Do not operate the stove with the glass
removed, cracked or broken.
FALL START UP
Prior to starting the rst re of the heating season, check the outside area around the exhaust and air intake
systems for obstructions. Clean and remove any y ash from the exhaust venting system. Clean any screens on
the exhaust system and on the outside air intake pipe. Turn all of the controls on and make sure that they are
working properly. This is also a good time to give the entire stove a good cleaning throughout.
SPRING SHUTDOWN
After the last burn in the spring, remove any remaining pellets from the hopper and the auger feed system. Scoop out the
pellets and then run the auger until the hopper is empty and pellets stop owing (this can be done by pressing the “ON”
button with the viewing door open). Vacuum out the hopper. Thoroughly clean the burn pot, and rebox. It may be desirable
to spray the inside of the cleaned hopper with an aerosol silicone spray if your stove is in a high humidity area. The exhaust
system should be thoroughly cleaned.
MAINTENANCE SCHEDULE
Use the following as a guide under average use conditions.
Gaskets around door and door glass should be inspected and repaired or replaced when necessary.
Daily Weekly Monthly or as needed
Burn Pot Stirred Empty
Combustion Chamber Brushed
Ashes Check Empty
Interior Chambers Vacuumed
Combustion Blower Blades Vacuumed / Brushed
Convection Blower Impeller Vacuumed / Brushed
Vent System Cleaned
Gaskets Inspected
Glass Wiped Cleaned
Hopper (end of season) Emptied and vacuumed
CAUTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
Maintenance
-17-
When your stove acts out of the ordinary, the rst reaction is to call for help. This guide may save time and money
by enabling you to solve simple problems yourself. Problems encountered are often the result of only ve factors:
1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You
can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer
to the diagrams to help locate indicated parts.
For the sake of troubleshooting and using this guide to assist you. You should look at your heat level setting to
see which light is ashing.
Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to “OFF”
does not disconnect all power to the electrical components of the stove.
Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Trouble Shooting Guide
STOVE SHUTS OFF AND THE #2 LIGHT FLASHES
Possible Causes: Possible Remedies: (Unplug stove rst when possible)
1. Airow switch hose or stove attachment pipes for
hose are blocked.
Unhook air hose from the air switch and blow through it. If
air ows freely, the hose and tube are ne. If air will not
ow throw the hose, use a wire coat hanger to clear the
blockage.
2. The air inlet, burnpot, interior combustion air
chambers, combustion blower, or exhaust pipe are
blocked with ash or foreign material.
Follow all cleaning procedures in the maintenance section of
the owner’s manual.
3. The rebox is not properly sealed.
Make sure the door is closed and that the gasket is in good
shape. If the ash door has a latch, make sure the ash door is
properly latched and the gasket is sealing good. If the stove
has just a small hole for the ashes to fall through under the
burnpot, make sure the slider plate is in place to seal off the
rebox oor.
4. Vent pipe is incorrectly installed.
Check to make sure vent pipe installation meets criteria in
owner’s manual.
5. The airow switch wire connections are bad.
Check the connectors that attach the gray wires to the air
switch.
6. The gray wires are pulled loose at the Molex
connector on the wiring harness.
Check to see if the gray wires are loose at the Molex
connector.
7. Combustion blower failure.
With the stove on, check to see if the combustion blower is
running. If it is not, you will need to check for power going to
the combustion blower. It should be a full current. If there is
power, the blower is bad. If there is not, see #8.
8. Control board not sending power to combustion
blower.
If there is no current going to the combustion blower, check
all wire connections. If all wires are properly connected, you
have a bad control board.
9. Control board not sending power to air switch.
There should be a 5-volt current (approximately) going to the
air switch after the stove has been on for 30 seconds.
10. Air switch has failed (very rare).
To test the air switch, you will need to disconnect the air hose
from the body of the stove. With the other end still attached
to the air switch, very gently suck on the loose end of the
hose (you may want to remove the hose entirely off the stove
and the air switch rst and make sure it is clear). If you hear
a click, the air switch is working. BE CAREFUL TOO MUCH
VACUUM CAN DAMAGE THE AIR SWITCH.
-18-
STOVE SHUTS OFF AND THE #3 LIGHT FLASHES
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. The hopper is out of pellets. Rell the hopper.
2. The air damper is too far open for a low feed setting.
If burning on the low setting, you may need to close the
damper all the way (push the knob in so it touches the side of
the stove).
3. The burnpot is not pushed completely to the rear of
the rebox.
Make sure that the air intake collar on the burnpot is touching
the rear wall of the rebox.
4. The burnpot holes are blocked. Remove the burnpot and thoroughly clean it.
5. The air inlet, the interior chambers, or exhaust system
has a partial blockage.
Follow all cleaning procedures in the maintenance section of
the owner’s manual.
6. The hopper safety switch has failed or hopper is open.
When operating the unit, be sure the hopper lid is closed so
that the hopper safety switch will activate. Check the wires
leading from the hopper safety switch to the control panel
and auger motor for secure connections. Use a continuity
tester to test the hopper safety switch; replace if necessary.
7. The auger shaft is jammed.
Start by emptying the hopper. Then remove the auger
motor by removing the auger pin. Remove the auger shaft
inspection plate in the hopper so that you can see the auger
shaft. Gently lift the auger shaft straight up so that the end of
the auger shaft comes up out of the bottom auger bushing.
Next, remove the two nuts that hold the top auger biscuit in.
Then rotate the bottom end of the auger shaft up towards
you until you can lift the shaft out of the stove. After you have
removed the shaft, inspect it for bent ights, burrs, or broken
welds. Remove any foreign material that might have caused
the jam. Also, check the auger tube for signs of damage
such as burrs, rough spots, or grooves cut into the metal that
could have caused a jam.
8. The auger motor has failed.
Remove the auger motor from the auger shaft and try to
run the unit. If the motor will turn the shaft is jammed on
something. If the motor will not turn, the motor is bad.
9. The Proof of Fire (POF) thermodisc has malfunctioned.
Temporarily bypass the POF thermodisc by disconnecting the
two brown wires and connecting them with a short piece
of wire. Then plug the stove back in. If the stove comes on
and works, you need to replace the POF thermodisc. This is
for testing only. DO NOT LEAVE THE THERMODISC BYPASSED.
Your blowers will never shut off and if the re went out, the
auger will continue to feed pellets until the hopper is empty if
you leave the POF thermodisc bypassed.
10. The high limit thermodisc has tripped or is defective.
Wait for the stove to cool for about 30 - 45 minutes. Locate
the High Limit thermodisc and press the reset button on the
back of it. If the heater will not restart, check the thermodisc
to see if it’s bad. To test if the thermodisc is bad, you can
bypass it as described previously for the POF thermodisc.
11. The fuse on the control board has blown.
Remove the control board. On the back there is one fuse. If
it appears to be bad, replace it with a 5 Amp, 125 Volt fuse.
Plug the stove back in and try to run the unit.
12. The control board is not sending power to the POF
thermodisc or other auger system components.
There should be a 5-volt (approximately) current going to the
POF thermodisc after the stove has been on for 10 minutes.
Trouble Shooting Guide
-19-
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. Air damper open too far for ignition.
Push the air damper in closer to the side of the stove for
startup. In some situations it may be necessary to have the
damper completely closed for ignition to take place. After
there is a ame, the damper can then be adjusted for the
desired feed setting.
2. Blockage in igniter tube or inlet for igniter tube.
Find the igniter housing on the backside of the rewall. The
air intake hole is a small hole located on bottom side of the
housing. Make sure it is clear. Also, look from the front of the
stove to make sure there is not any debris around the igniter
element inside of the igniter housing.
3. The burnpot is not pushed completely to the rear of
the rebox.
Make sure that the air intake collar on the burnpot is touching
the rear wall of the rebox.
4. Bad igniter element.
Put power directly to the igniter element. Watch the tip of
the igniter from the front of the stove. After about 2 minutes
the tip should glow. If it does not, the element is bad.
5. The control board is not sending power to the igniter.
Check the voltage going to the igniter during startup. It
should be a full current. If the voltage is lower than full
current, check the wiring. If the wiring checks out good, the
board is bad.
SMOKE SMELL COMING BACK INTO THE HOME
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. There is a leak in the vent pipe system.
Inspect all vent pipe connections. Make sure they are sealed
with RTV silicone that has a temperature rating on 500 degree
F or higher. Also, seal joints with UL-181-AP foil tape. Make
sure the square to round adapter piece on the combustion
blower has been properly sealed with the same RTV.
2. The gasket on the combustion blower has gone bad.
Inspect both gaskets on the combustion blower to make sure
they are in good shape.
Because it is a wood-burning device, your pellet heater may emit a faint wood-burning odor. If this increases beyond
normal, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. All
joints should be properly sealed. Also clean your stove, following instructions in “MAINTENANCE”. If problem persists,
contact your dealer.
CONVECTION BLOWER SHUTS OFF AND COMES BACK ON
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. The convection blower is overheating and tripping
the internal temperature shutoff.
Clean any dust off of the windings and fan blades. If
cleaning the blower does not help, the blower may be bad.
2. Circuit board malfunction.
Test the current going to the convection blower. If there is
power being sent to the blower when it is shut off, then the
control board is ne. If there is NOT power being sent to the
blower when it shuts off during operation, then you have a
bad control board.
Trouble Shooting Guide
-20-
STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. Fuse on control board blew.
Remove the control board. On the back there is one fuse. If
it appears to be bad, replace it with a 5 Amp 125 Volt fuse.
Plug the stove back in and try to run the unit.
2. High limit switch has tripped or is defective.
Wait for the stove to cool for about 30 - 45 minutes. Locate
the High Limit thermodisc and press the reset button on the
back of it. If the heater will not restart, check the thermodisc
to see if it’s bad. To test if the thermodisc is bad, you can
bypass it as described previously for the POF thermodisc.
3. Bad Auger Motor.
Remove the auger motor from the auger shaft and try to
run the unit. If the motor will turn, the shaft is jammed on
something. If the motor will not turn, the motor is bad.
4. Auger Jam.
Start by emptying the hopper. Then remove the auger
motor by removing the auger pin. Remove the auger shaft
inspection plate in the hopper so that you can see the auger
shaft. Gently lift the auger shaft straight up so that the end of
the auger shaft comes up out of the bottom auger bushing.
Next, remove the two nuts that hold the top auger biscuit in.
Then rotate the bottom end of the auger shaft up towards
you until you can lift the shaft out of the stove. After you have
removed the shaft, inspect it for bent ights, burrs, or broken
welds. Remove any foreign material that might have caused
the jam. Also, check the auger tube for signs of damage
such as burrs, rough spots, or grooves cut into the metal that
could have caused a jam.
5. Loose wire or connector.
Check all wires and connectors that connector to the auger
motor, high limit switch, and the Molex connector.
6. Bad control board.
If the fuse is good, the wires and connectors check out good,
and the high limit switch did not trip, test for power going
to the auger motor. If there is not a full current going to the
auger motor when the fuel feed light is on, you have a bad
control board.
HIGH LIMIT SWITCH KEEPS TRIPPING
Possible Causes Possible Remedies: (Unplug stove rst when possible)
1. The convection blower is overheating and tripping
the internal temperature shutoff.
Clean any dust off of the windings and fan blades. If oiling
the blower does not help, the blower may be bad.
2. The stove is being left on the highest setting for
extended periods of time.
If operating the heater on the highest heat setting, the room
temperature could increase enough and lead to potential
overheating situations. If this happens, try operating at a
lower heat setting.
3. Fuel other than wood pellets is being burned in the
stove.
This pellet stove is designed and tested to use wood pellets.
Check for signs of fuel other than wood pellets. No other
types of fuel have been approved for this pellet stove. If
there are signs of other types of fuel being used, stop using
them immediately.
4. Power surge or brown out situation.
A power surge, spike, or voltage drop could cause the high
limit switch to trip. Check to see if a surge protector is being
used on the stove. A battery backup may be used if rated at
least 1000W.
5. High limit switch is malfunctioning. If the other items check out OK, replace the high limit switch.
Trouble Shooting Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

US Stove Company 5520 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

dans d''autres langues