HARVIA HL Series Le manuel du propriétaire

Taper
Le manuel du propriétaire
Owner’s/Operator’s Manual
Manuel de l’utilisateur/opérateur
Sauna heater installation, wiring,
operating instructions, troubleshooting,
maintenance and guarantee.
IMPORTANT! This manual must
be left with owner, manager, or
operator of Sauna after it is used by
electrician!
MODEL
HL(S)6U1S(A) 6,0 kW
HL(S)7U1S(A) 6,8 kW
HL(S)8U1S(A) 8,0 kW
HL(S)9U1S(A) 9,0 kW
HL(S)11U1S(A) 10,5 kW
HL(S)11U3S(A) 10,5 kW
Instructions d’installation, de câblage
et d’utilisation, dépannage, entretien
et garantie du poêle de sauna.
IMPORTANT ! Ce manuel doit être
remis au propriétaire, au gérant ou à
l’opérateur du sauna après avoir été
utilisé par l’électricien !
Sauna Specialiste Inc.
Dessere Nord Autoroute 440 O
Laval, Quebec, H7L 3W3
Toll free: 1 855-689-2422
Harvia US Inc.
3567 Jefferson St. N,
Lewisburg, WV 24901
+1 304-497-3991
15122022 / Y05-0898
FI SV
2
!
!
< 0°C / < 32 °F
18-25
°C / +64-77°F
~8h
!Overheat protector of the device can go off
also at temperatures below -5˚C / 23˚F
(storage, transport, environment). Before
installation take the device to the warm environ-
ment. The overheat protector can be reset when the
temperature of the device is approx 18˚C / 64˚F.
The overheat protector must be reset before using
the device. See the user manual > Resetting the
Overheat Protector.
!La sécurité-surchauffe de l’appareil peut
également se déclencher à des températures
inférieures à -5 ˚C / 23 ˚F (stockage, tran-
sport, environnement). Avant l’installation, placez
l’appareil dans un endroit chaud. La sécurité-sur-
chauffe peut être réinitialisée quand la température
de l’appareil se situe à env. 18 ˚C / 64 ˚F. La -
curité-surchauffe doit être réinitialisée avant
d’utiliser cet appareil. Reportez-vous au manuel >
Réinitialisation de la sécurité-surchauffe.
CONTENTS
WARNINGS ............................................................. 3
1. INSTRUCTIONS FOR USE ........................................... 4
1.1. Piling of the Sauna Stones ..................................4
1.1.1. Maintenance ............................................4
1.2. Heating of the Sauna .........................................4
1.2.1. Using the Heater .......................................4
1.2.2. Throwing Water on Heated Stones ..............4
1.3. Heating of the Sauna Using the Steamer ..............5
1.3.1. Filling the Water Reservoir ..........................5
1.3.2. Draining the Water Reservoir ......................5
1.3.3. Combi Heaters with an Automatic
Water Filling System ...........................................5
1.4. The Use of Fragrances .......................................5
1.5. Drying the Sauna Room .....................................6
1.6. Cleaning the Steamer.........................................6
1.7. Instructions for Bathing ..................................... 6
1.8. Troubleshooting ................................................6
2. THE SAUNA ROOM ...................................................7
2.1. Insulation and Wall Materials of the Sauna Room ..7
2.1.1. Room construction –
general information ...............................................7
2.1.2. Darkening of the Sauna Walls .....................7
2.2. Sauna Room Floor .............................................7
2.3. Heater Output ...................................................7
2.4. Sauna Room Ventilation .....................................7
2.5. Hygienic Conditions of the Sauna Room ................8
3. INSTRUCTIONS FOR INSTALLATION ...........................9
3.1. Prior to Installation ............................................9
3.2. Place and Safety Distances ................................9
3.3. Heater fence .....................................................9
3.4. Installation of the Control Unit and Sensors ........10
3.4.1. Suitable control units ...............................10
3.5. Electrical Connections ......................................12
3.6. Automatic filling ..............................................12
3.7. Installing the Heater ........................................12
3.8. Electric heater insulation resistance ...................12
3.9. Replacing the Heating Elements ........................12
3.10. Resetting the Overheat Protectors of
the Heater and the Water Reservoir .......................... 13
4. SPARE PARTS ........................................................14
GUARANTEE .........................................................27
MAINTENANCE INSTRUCTIONS ...................................28
TABLE DES MATIÉRS
Avertissements ......................................................15
1. MODE D’EMPLOI .....................................................16
1.1. Mise en place des pierres du poêle ....................16
1.1.1. Maintenance ..........................................16
1.2. Chauffage du sauna.........................................16
1.2.1. Utilisation du poêle ..................................16
1.2.2. Projection de l’eau sur les pierres ..............16
1.3. Chauffage du sauna, avec vaporisateur ..............17
1.3.1. Remplissage du réservoir d´eau ................17
1.3.2. Vidange du réservoir d’eau ....................... 17
1.3.3. Poêles Combi équipés d’un système
automatique de remplissage d’eau ......................17
1.4. Emploi de parfums ..........................................17
1.5. Séchage du sauna ..........................................18
1.6. Nettoyage du vaporisateur ................................18
1.7. Conseils pour la séance de sauna ......................18
1.8. Dépannage .....................................................18
2. LE SAUNA ..............................................................19
2.1. Isolation du sauna et matériaux muraux ............19
2.1.1. Structure du sauna -
informations d’ordre général ...............................19
2.1.2. Noircissement des murs du sauna .............19
2.2. Revêtement de sol du sauna ............................19
2.3. Puissance du poêle ......................................... 19
2.4. Ventilation de la cabine de sauna ......................19
2.5. Hygiène du sauna ...........................................20
3. INSTRUCTIONS D’INSTALLATION .............................21
3.1. Avant l’installation .........................................21
3.2. Emplacement et distances de sécurité ................ 21
3.3. Ceinture de protection du poêle .........................21
3.4. Installation du centre de contrôle et du capteur ...21
3.4.1. Centres de contrôle adaptés .....................22
3.5. Raccordement électrique ..................................22
3.6. Système automatique de remplissage d’eau ........ 23
3.7. Installation du poêle.........................................23
3.8. Résistance d’isolation du poêle électrique ...........23
3.9. Remplacement des éléments de résistance .........23
3.10. Réinitialisation du fusible de surchauffe
du poêle et du réservoir d’eau ..................................23
4. PIÈCES DÉTACHÉES ................................................ 26
GARANTIE ............................................................27
INSTRUCTIONS D’ENTRETIEN ......................................28
EN
4
PLEASE READ THE INSTRUCTIONS FOR USE CAREFULLY BEFORE USING THE HEATER.
WARNINGS
Keep away from the heater when it is hot. The stones and outer surface of the heater may burn
your skin.
Do not throw too much water on the stones. The evaporating water is boiling hot.
Do not let young, handicapped or ill people bathe in the sauna on their own.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
Consult your doctor about any health-related limitations to bathing.
Parents should keep children away from the hot heater.
Consult your child welfare clinic about taking little babies to the sauna.
- age?
- temperature of the sauna?
- time spent in the warm sauna?
Be very careful when moving in the sauna, as the platform and floors may be slippery.
Do not smoke, use alcohol, or exercise in the sauna.
Do not exceed 30 min. in the sauna at one time, as excessive exposure can be harmful to health. The
sauna should not be used as an endurance test.
Persons with poor health should consult their physicians before using the sauna.
Do not place any combustible material over the sauna heater (towels, bathing suits, wooden bucket or
ladle)!
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the normal body temperature of 98,6 ºF. The symptoms of hyperthermia include an increase in the
internal temperature of the body, dizziness, lethargy, drowsiness, and fainting.
The effects of hyperthermia include:
A. Failure to perceive heat
B. Failure to recognize the need to exit the room
C. Unawareness of impending hazard
D. Fetal damage in pregnant women
E. Physical inability to exit the room
F. Unconsciousness
WARNING – the use of alcohol, drugs, or
medication is capable of greatly increasing the
risk of fatal hyperthermia.
Use only clean tap water on the stones – do
not use pool or spa water, as chlorine gas can
be produced and the heating elements can be
damaged!
Sea air and a humid climate may corrode the
metal surfaces of the heater.
Do not empty the water reservoir until the
device has been unused for at least an hour.
Be careful, because the hot steam may cause
burns.
No such objects or devices should be placed
inside the heater rock space or near the heater
that could change the amount or direction of
the air flowing through the heater, thus causing
the resistance temperature to rise too high,
which may set the wall surfaces on fire!
Purpose of the electric heater:
The HL electric heater is intended for use in a well heat-insulated family sauna. It is forbidden to use the
heater for any other purposes.
The guarantee period of an HL electric heater in family use is one year and in communal use, 3 months.
Please read the user’s instructions carefully before using the heater.
NOTE!
These instructions for installation and use are intended for the owner or the person in charge of the sauna,
as well as for the electrician in charge of the electrical installation of the heater.
Watch out for the hot surface!
Do not operate heater without stones or if the
stones has been piled incorrectly. Inadequately
filled stone space causes fire risk.
Always fill the water reservoir before use!
Do not operate heater without the service
hatch.
EN
5
1. INSTRUCTIONS FOR USE
1.1. Piling of the Sauna Stones
The piling of the sauna stones has a great effect on
the functioning of the heater (figure 1).
Important information on sauna stones:
The stones should be 2–4’’ (5–10 cm) in
diameter.
Use solely angular split-face sauna stones that
are intended for use in a heater. Peridotite,
olivine-dolerite and olivine are suitable stone
types.
Neither light, porous ceramic “stones“ nor soft
soapstones should be used in the heater. They
do not absorb enough heat when warmed up.
This can result in damage to heating elements.
Wash off dust from the stones before piling
them into the heater.
Please note when placing the stones:
Do not drop stones into the heater.
Place the stones sparsely to ensure that air can
circulate between them.
Do not form a high pile of stones on top of the
heater.
No such objects or devices should be placed
inside the heater stone space or near the
heater that could change the amount or
direction of the air flowing through the heater.
1.1.1. Maintenance
Due to large variation in temperature, the sauna
stones disintegrate in use. Rearrange the stones at
least once a year or even more often if the sauna is
in frequent use. At the same time, remove any piec-
es of stones from the bottom of the heater and re-
place any disintegrated stones with new ones. By
doing this, the heating capability of the heater stays
optimal and the risk of overheating is avoided.
Pay attention especially to the gradual settling
of the stones. Be sure that the heating ele-
ments do not appear with time. The stones settle
most rapidly within the first two months of piling.
1.2. Heating of the Sauna
When operating the heater for the first time, both the
heater and the stones emit smell. To remove the smell,
the sauna room needs to be efficiently ventilated.
If the heater output is suitable for the sauna room,
it will take about an hour for a properly insulated
sauna to reach the required bathing temperature (
2.3.). The sauna stones normally reach the bathing
temperature at the same time as the sauna room. A
suitable temperature for the sauna room is about
149–167 °F (65–75 °C).
Before switching the heater on always check
that there isn’t anything on top of the heater
or inside the given safety distance.
1.2.1. Using the Heater
Heater is controlled from a separate control unit.
See the instructions for use of the selected control
unit model.
1.2.2. Throwing Water on Heated Stones
The air in the sauna room becomes dry when
warmed up. Therefore, it is necessary to throw
water on the heated stones to reach a suitable level
of humidity in the sauna. The effect of heat and
steam on people varies – by experimenting, you
can find the levels of temperature and humidity
that suit you best.
The maximum volume of the ladle is 0,05 gal
(0.2 litres). If an excessive amount of water is
poured on the stones, only part of it will evaporate and
the rest may splash as boiling hot water on the bathers.
Never throw water on the stones when there are
people near the heater, because hot steam may burn
their skin.
The water to be thrown on the heated stones
should meet the requirements of clean household
water (table 1). Only special aromas designed for
sauna water may be used. Follow the instructions
given on the package.
Figure 1. Piling of the sauna stones
EN
6
1.3. Heating of the Sauna Using the Steamer
With the Combi heater, the sauna can be heated
either in the usual way or by using its evaporator.
Always fill the water reservoir before use!
The evaporator has a 1,3 gal (5 l) water tank
so it can be on continuously for approximately
2 hours. The tank should be filled when the
heater is cold.
1.3.1. Filling the Water Reservoir
Fill the reservoir with clean household water always
before use. The maximum capacity of the reservoir
is approximately 1,3 gal (5 litres). Figure 2.
Switch the device off before adding the water to
the hot steamer.
Be careful, because the hot steam may
cause burns.
1.3.2. Draining the Water Reservoir
Drain the water from the reservoir always after use
when the water has cooled down. This procedure
removes impurities condensed in the reservoir as
result of evaporation.
1.3.3. Combi Heaters with an Automatic Water
Filling System
Combi heaters that have an automatic water filling
system fill the tank automatically if the evaporator
is in the ON-position.
1.4. The Use of Fragrances
Liquid fragrances and fragrance bags can be used
in the steamer. Liquid fragrances are poured into
the stone cups in the steamer. Fragrance bags are
placed on top of the steam grating.
When using fragrances, mind the hot steam
1
2
Draining the water reservoir
Filling the water reservoir
max.
5 l
min.
Always fill the water reservoir before use!
Caution Very
hot Water!
Figure 2. Filling and draining the water reservoir
Table 1. Water quality requirements
Water properties Effect Recommendation
Humus concentration Colour, taste, precipitates <12 mg/l
Iron concentration Colour, odour, taste, precipitates <0,2 mg/l
Manganese (Mn) concentration Colour, odour, taste, precipitates <0,10 mg/l
Hardness: most important substances are
magnesium (Mg) and lime, i.e. calcium (Ca)
Precipitates Mg: <100 mg/l
Ca: <100 mg/l
Chloride-containing water Corrosion Cl: <100 mg/l
Chlorinated water Health risk Forbidden to use
Seawater Rapid corrosion Forbidden to use
Arsenic and radon concentration Health risk Forbidden to use
EN
7
evaporating from the steamer as it may burn. Avoid
adding of water and placing of fragrances to a hot
steamer.
The stone cups must be washed with running
water as often as necessary.
1.5. Drying the Sauna Room
The sauna room must always be allowed to dry
thoroughly after the steamer has been used. In
order to speed up the drying process, the heater
can be left on with the sauna ventilation also on to
the maximum.
If the heater is used to help dry out the sauna
room, remember to switch it off after the given
period of time.
1.6. Cleaning the Steamer
Impurities from water, e.g. lime, will accumulate
on the walls of the steamer’s water reservoir.
For decalcification we recommend decalcifying
agents intended for household appliances, e.g.
coffeemakers and water kettles. These agents are
to be used as instructed by the manufacturer. The
outside of the steamer can be cleaned with the
damp cloth. When cleaning the outside, ensure that
the steamer’s operating switch is OFF.
1.7. Instructions for Bathing
Begin by washing yourself.
Stay in the sauna for as long as you feel
comfortable.
Forget all your troubles and relax.
According to established sauna conventions,
you must not disturb other bathers by
speaking in a loud voice.
Do not force other bathers from the sauna by
throwing excessive amounts of water on the
stones.
Cool your skin down as necessary. If you
are in good health, you can have a swim if a
swimming place or pool is available.
Wash yourself after bathing.
Rest for a while and let your pulse go back to
normal. Have a drink of fresh water or a soft
drink to bring your fluid balance back to normal.
1.8. Troubleshooting
All service operations must be done by
professional licensed maintenance personnel.
If the steamer does not work, check the following:
Is the water level in the reservoir sufficient?
(see section 1.3.).
Has the overheat protector engaged? (reset
button on bottom of steamer 3.10.).
Is the humidity in the sauna too high?
Is the steamer thermostat set at maximum?
Check that thermostat sensor of the water res-
ervoir is over the heating element and overheat
protection sensor is under the heating element
(see the installation instructions for control
unit).
The heater does not heat.
Check that the breakers to the heater are in
good condition.
Check that the connection cable is connected.
Check that the control panel shows a higher
figure than the temperature of the sauna.
Check that the overheat protectors have not
gone off. Figure 11.
Check that the breaker is switched on. Also,
breaker should be correct size.
The sauna room heats slowly. The water thrown
on the sauna stones cools down the stones
quickly.
Check that the breakers to the heater are in
good condition.
Check that all heating elements glow when the
heater is on.
Turn the temperature to a higher setting.
Check that the heater output is sufficient
(2.3.).
Check that the sauna room ventilation has been
arranged correctly ( 2.4.).
The sauna room heats quickly, but the
temperature of the stones remain insufficient.
Water thrown on the stones runs through.
Check that the heater output is not too high
(2.3.).
Check that the sauna room ventilation has been
arranged correctly ( 2.4.).
Panel or other material near the heater darkens
quickly.
Check that the requirements for safety
distances are fulfilled ( 3.2.).
Check that no heating elements can be seen
behind the stones. If heating elements can be
seen, rearrange the stones so that the heating
elements are covered completely ( 1.1.).
Also see section 2.1.1.
The heater emits smell.
See section 1.2.
The hot heater may emphasize odours mixed
in the air that are not, however, caused by the
sauna or the heater. Examples: paint, glue, oil,
seasoning.
The heater makes noise.
Occasional bangs are most likely caused by
stones cracking due to heat.
The thermal expansion of heater parts can
cause noises when the heater warms up.
x 2
Figure 3. Installing the safety grid
EN
8
2.1. Insulation and Wall Materials of the
Sauna Room
In an electrically heated sauna, all the massive wall
surfaces which store plenty of heat (such as bricks,
glass blocks, plaster etc.), must be sufficiently insu-
lated in order to keep the heater output at a reasonably
low level.
A wall and ceiling construction can be considered
to have efficient thermal insulation if:
the thickness of carefully fitted insulating wool
inside the structure is 4” (100 mm) minimum
2” (50 mm).
the moisture protection consists of e.g.
aluminium paper with tightly taped edges. The
paper must be fitted so that the glossy side is
towards the inside of the sauna.
there is a 1/4” (10 mm) vent gap between
the moisture protection and panel boards
(recommendation).
the inside is covered by 1/2” – 5/8” (12–16
mm) thick panelling.
there is a vent gap of a few millimetres at the
top of the wall covering at the edge of the ceiling
panelling.
When aiming at a reasonable heater output, it may be
advisable to lower the ceiling of the sauna, (minimum
height 75” (1900 mm)). As a result, the volume of the
sauna is decreased, and a smaller heater output may
be sufficient. The ceiling can be lowered so that the
ceiling joists are fixed at a suitable height. The spaces
between the joists are insulated (minimum insulation
4” (100 mm)) and surfaced as described above.
Because heat goes up wards, a maximum distance
of 47” (1200 mm) is recom mended between the
bench and ceiling.
NOTE! The protection of the walls or ceiling with
heat protection, such as mineral board fitted directly
on the wall or ceiling, may cause the temperature of
the wall and ceiling materials to rise dangerously high.
2.1.1. Room construction general information
FRAMING
2” x 4” (50 x 100 mm) any suitable wood material,
16” (406 mm) o.c.
CEILING HEIGHT
No higher than 7’ 6” (2300 mm).
INSULATION
R11 Fiberglas with foil back in walls and ceiling, foil
facing into room.
DRYWALL
See local codes. Is not required in most residences.
See local codes for commercial. If drywall is used
apply 1” x 2” (25 x 50 mm) nailers so that wall and
ceiling boards can be attached to solid wood.
PANELING
Use kiln-dried softwood (with moisture content not
exceeding 11 %).
BENCHES
Use matching softwood. Fasten from bottom to
prevent burning of bathers.
DOOR
Must open out and should not have a lock. Types
of door fastenings that may be used are magnetic
catches, friction catches, spring-loaded or gravity
loaded door closers, and the like.
ROOM LIGHT
Should be a vapor proof, wall mounted type, with
rough-in box mounted flush with inside paneling.
It should be mounted 6’’ (150 mm) from ceiling, not
directly over the sauna heater, and not over upper
benches. It could be installed under benches. Light
bulb should not exceed recommended watts of the
light manufacturer.
Note! Receptacles OR PLUGS are not allowed in
a Sauna room. If a speaker is installed in a Sauna
room, it should not be installed higher than 3’ (914
mm) from floor, away from the Sauna heater (con-
sult manufacturer for ratings).
2.1.2. Darkening of the Sauna Walls
It is perfectly normal for the wooden surfaces of the
sauna room to darken in time. The darkening may
be accelerated by
sunlight
heat from the heater
protective agents on the walls (protective
agents have a poor heat resistance level)
2.2. Sauna Room Floor
Due to a large variation in temperature, the sauna
stones disintegrate in use.
Small pieces of stone are washed down on the
sauna room floor along with the water thrown on
the rocks.
To prevent aesthetic damage only dark joint
grouts and floor coverings made of rock materials
should be used underneath and near the heater.
2.3. Heater Output
When the walls and ceiling are covered with panels,
and the insulation behind the panels is sufficient to
prevent thermal flow into the wall materials, the
heater output is defined according to the cubic vol-
ume of the sauna. See table 2.
Because log walls are heated slowly, the cubic
volume of a log sauna should be multiplied by 1.5,
and the heater output should then be selected on
the basis of this information.
2.4. Sauna Room Ventilation
Should be provided by lower vent close to heater,
4” (100 mm) from floor, and upper vent on opposite
wall (if possible) 6” (150 mm) from ceiling or as
low as 24” (600 mm) from floor. Vents should be
adjustable and should allow air to change 5 times
per hour. Sauna shall be provieded with intended
ventilation as required per the local code authori-
ties. See figure 3.
2. THE SAUNA ROOM
EN
9
2.5. Hygienic Conditions of the Sauna Room
Good hygienic standards of the sauna room will
make bathing a pleasant experience.
The use of sauna seat towels is recommended to
prevent sweat from flowing onto the platforms. The
towels should be washed after each use. Separate
towels should be provided for guests.
It is advisable to vacuum or sweep the floor of
the sauna room in connection with cleaning. In ad-
Figure 4. Ventilation of the sauna room and min. clearances from wall and fence
TILE
CARRELAGE
AIR IN
ARRIVÉE
D’AIR
CONCRETE
BÉTON
AIR OUT
ÉVACUATION
D’AIR
6"
4"
FENCE
CEINTURE DE
PROTECTION
min. 1’
min.
2’’
min.
2’’ min. 28’
360° 180°
>40”/1000 mm
>20”/500 mm
Figure 5. Sensor’s minimum distance from an air vent
dition, the floor may be wiped with a damp cloth.
The sauna room should be thoroughly washed at
least every six months. Brush the walls, platforms
and floor by using a scrubbing-brush and sauna
cleanser. Then rinse the saunaroom by using clean
household water. Remove lime stains from the heat-
er using a 10% citric acid solution and rinse.
Wipe dust and dirt from the heater with a damp
cloth.
WOOD FENCE
CEINTURE DE
PROTECTION
EN BOIS
min. 2’ min. 2’
min. 2’
min. 2’
EN
10
3. INSTRUCTIONS FOR INSTALLATION
3.1. Prior to Installation
Prior to installing the heater, read all the instructions
for installation (figure 9), as well as checking the fol-
lowing points:
The heater volume should be suitable for the
sauna room volume. Table 2 shows the mini-
mum and maximum volumes for each heater
output. A precondition for the given values is
that the sauna room is well heatinsulated.
Walls and ceiling are covered with wood panel.
Check that supply voltage and amperages are
available for the heater.
The breakers and the connection cables con-
form with valid regulations and their dimen-
sions are in accordance with table 3.
The location is suitable for the heater (3.2.).
3.10. Resetting the Overheat Protector
Note! Only one electrical heater may be in-
stalled in the sauna room.
3.2. Place and Safety Distances
The minimum safety distances are described in
figure 4 and 6.
It is absolutely necessary to install the heater
according to these values. Neglecting them
causes a risk of fire. ( 3.7.)
Hot pieces of stone can damage floor coverings
and cause a risk of fire. The floor coverings of
the installation place should be heat-resistant.
3.3. Heater fence
It is necessary for safety and should be constructed
of softwood to match sauna interior. See figures
4 and 6 for clearances from sauna heater. Fence
should be attached to wall and should not be placed
higher than top of heater below rock line.
Heater Output Vaporizer Dimensions Stones Sauna room
Out-
put Max. va-
porisation
efficiency
Width/Depth/
Height
Weight Cubic vol. Floor Area Height
kW kW kg/h
inch
mm lb/kg
max.
lb/kg
2.3.!
min.
CuFt/m³
max.
CuFt/m³
min
sqft
max
sqft
min.
inch/mm
HL(S)6U1S(A) 6,0 2,1 2,5 16/16/33 63,9 29 110 50 177 5 294 8 28 47 75 1900
415/410/840
HL(S)7U1S(A) 6,8 2,1 2,5 16/16/33 63,9 29 110 50 177 5 354 10 28 57 75 1900
415/410/840
HL(S)8U1S(A) 8,0 2,1 2,5 16/16/33 63,9 29 110 50 177 5 431 12 28 69 75 1900
415/410/840
HL(S)9U1S(A) 9,0 2,1 2,5 16/16/33 63,9 29 110 50 177 5 494 14 28 79 75 1900
415/410/840
HL(S)11U1S(A)
HL(S)11U3S(A) 10,5 2,1 2,5 16/19/33 70,5 32 154 70 177 5 635 18 28 102 75 1900
415/485/840
Table 2. Installation details of the heater
4"
100mm 4"
100mm
min.
2,8’’/70mm
A
BB
AA
A
A A
Note: Control panel and power unit must be installed in a dry
place; away from spa, pool or shower; not outdoors. A
receptacle shall not be installed inside the sauna room.
Load Center
Control Panel
Power Unit
Sensor
SEAL TIGHT CONDUIT
90°C WIRE
Load center shall be supplied
by electrical contactor during
field wiring. Load center can
be located in other serviceable
places, as well as location
shown on this diagram.
Main Electrical Panel
inch mm
A2 50
B 42 1060
Figure 6. Sauna control / Minimum safety distances / Installing the temperature sensor
EN
11
Figure 7. Automatic filling
Shut-off valve
Vacuum breaker
Connection hose
Cold water
150–400 kPa
(1,5–4,0 bar)
Table 3. Supply wires (from the power unit to the heater)
Table 4. Heater grade setting of the control unit
Heater model Input
kW
Voltage Phase Amperage Min. 90 °C
Copper supply
wire AWG No.
Suitable control
units
HL(S)6U1S(A) 6,0 + 2,1 240 1 (2 Groups) 17,1 (2 Groups) 14 CX30C-U1
HL(S)7U1S(A) 6,8 + 2,1 240 1 (2 Groups) 18,8 (2 Groups) 12 CX30C-U1
HL(S)8U1S(A) 8,0 + 2,1 240 1 (2 Groups) 22,1 (2 Groups) 12 CX30C-U1
HL(S)9U1S(A) 9,0 + 2,1 240 1 (2 Groups) 25 (2 Groups) 10 CX30C-U1
HL(S)11U1S(A) 10,5 + 2,1 240 1 (2 Groups) 29,2 (2 Groups) 10 CX30C-U1
HL(S)11U3S(A) 10,5 208 3 29,2 10 CX30C-U3
Heater model Heater grade setting of the
control units
HL(S)6U1S(A) d4
HL(S)7U1S(A) d4
HL(S)8U1S(A) d4
HL(S)9U1S(A) d4
HL(S)11U1S(A) d2
HL(S)11U3S(A) d2
EN
12
3.4. Installation of the Control Unit and Sensors
The control unit includes detailed instructions
for fastening the unit on the wall and installing
the humidity sensor.
Install the sensor (WX248), which comes with
the heater, as shown in figure 6.
Do not place the supply air vent so that the air
flow cools the temperature sensor. Figure 5.
3.4.1. Suitable control units
Harvia CX30C-U1
Harvia CX30C-U3
See more detailed information from table 3.
Heater grade setting of the control unit: See table 4.
Please read the instructions of the control unit.
3.5. Electrical Connections
The heater may only be connected to the electrical
network in accordance with the current regulations
by an authorised, licensed professional electrician.
The wiring diagrams are included in the control
unit’s installation instruction.
Further instructions concerning exceptional installa-
tions can be obtained from local electrical authorities.
1. Remove heater from carton and place in
proper location in sauna room. Observe proper
clearances as per figures 4 and 6.
2. See applicable wiring diagram for heater model
(figure 8, see control unit manual for detailed
instructions how to connect the heater and
the control unit). Heater must be permanently
installed by using seal tight conduit between
the heater and the wall of the sauna room
(pigtails or plugs are not allowed in the sauna
room). Wiring must be done by a licensed
electrician, who must follow wiring diagram
provided and adhere to local codes. Use proper
AWG rated wire size and use copper wire
suitable for 194 °F (90 °C) within sauna walls.
Use grounding terminals provided in sauna
heater and control unit to properly ground the
equipment as per NEC and local codes.
3. Inside the heater box there are two signs.
Please place the metal ”CAUTION” sign on
the interior wall of the sauna room directly
above the heater in a visible place (screws and
nails included). Place the metal ”WARNING”
sign outside, on the door of the sauna room.
”MAINTENANCE INSTRUCTIONS” are at the
end of this manual.
3.6. Automatic filling
Connect the heater to cold water mains using a
flexible hose. Make sure that the connection has a
shut-off valve and vacuum breaker. See figure 7.
The sauna and/or washing facilities should have a
floor drain in case of hose damage or leaks. Follow
the local installation regulations.
!Overheat protector of the device can go off
also at temperatures below -5˚C / 23˚F
(storage, transport, environment). Before
installation take the device to the warm environ-
ment. The overheat protector can be reset when the
temperature of the device is approx 18˚C / 64˚F.
The overheat protector must be reset before using
the device.
3.7. Installing the Heater
See figure 9.
Connect cables to the heater.
Connect the heater to cold water mains using a
flexible hose (automatic filling).
Place the heater and adjust the heater vertically
straight using the adjustable legs.
3.8. Electric heater insulation resistance
When performing the final inspection of the electrical
installations, a “leakage” may be detected when meas-
uring the heater’s insulation resistance. The reason
for this is that the insulating material of the heating
resistors has absorbed moisture from the air (storage
transport). After operating the heater for a few times,
the moisture will be removed from the resistors.
Do not connect the power feed for the heater
through the RCD (residual current device)/GFI
(Ground Fault Interrupter)!
3.9. Replacing the Heating Elements
See figure 10.
3.10. Resetting the Overheat Protectors of
the Heater and the Water Reservoir
See figure 11. If the temperature of the sauna room
becomes dangerously high, the overheat protector
(1) will permanently cut off the supply of the heater.
The overheating protector (1) can be reset after
the heater has cooled down. Please check that the
stones are piled properly and the sensor is installed
according the installation instructions. See also the
installation instructions for control unit.
If water reservoir empties during the use, the
overheat protector (2) cuts off the steamer power.
The overheating protector (2) can be reset after the
steamer has cooled down.
The reset button is located under the heater.
EN
13
Figure 8. Electrical connections of heater
HL(S)6U1SA, HL(S)8U1SA
HL(S)9U1SA, HL(S)11U1SA
HL(S)11U3SA
10 A
10 A
P
auto
P
man
A1
K
W1
L2
GND
L1
L1
L2
10 A
10 A
Pauto
Pman
A1
K
W1
L3
GND
L1
L3a
L2
* *
** **
240V 1-Phase Combi heater
(Automatic and manual water filling)
208V 3-Phase Combi heater
(Automatic and manual water filling)
* Remove copper jumper when using manual water filling
** P auto = Automatic water filling
P man = Manual water filling
W1
GND
L1 L1L2 L2
A1
K
P
10 A
HL(S)7U1S
HL(S)9U1S
HL(S)11U1S
240V 1-Phase Combi heater
(Manual water filling)
EN
14
Figure 10. Replacing the Heating Elements
Figure 11. Resetting the Overheat Protectors of the Heater and the Water Reservoir
Figure 9. Opening the cover of the service hatch. Connections of the heater
A. Connection box
B. Connection cable
A
B
1
34
2
1
2
Exemple d'installation,
pièces non fournies
1
1
2
EN
15
4. SPARE PARTS
1Heating element 2000 W/240 V
Heating element 2250 W/240 V
Heating element 2650 W/240 V
Heating element 3000 W/240 V
Heating element 3500 W/240 V
Heating element 3500 W/208 V
Y10-0021
Y10-0010
Y10-0020
Y10-0009
Y10-0007
Y10-0006
HL(S)6U1S(A)
HL(S)7U1S(A)
HL(S)8U1S(A)
HL(S)9U1S(A)
HL(S)11U1S(A)
HL(S)11U3S(A)
3
3
3
3
3
3
2 Evaporator heating element, assembled 2100 W/240 V
Evaporator heating element, assembled 2100 W/208 V
ZH-104
Y10-0013
1
1
3 Water reservoir, assembled ZCU-115 1
4 Solenoid valve ZSS-610
HL(S)6U1S(A)
HL(S)7U1S(A)
HL(S)8U1S(A)
HL(S)9U1S(A)
HL(S)11U1S(A)
HL(S)11U3S(A)
1
5 Overheating protector 140oC ZSK-764 1
6 Thermostat 110oC ZSN-250 1
7 Soapstone cup ZH-205 1
8 Silicon hose 7/10 ZCU-350 / ZH-170 1
9 Silicon hose 12/16 ZCU-352 / ZH-175 1
10 Bracket for thermostat ZH-128 1
11 Steam control ZCU-614 1
12 Temperature sensor WX248 1
13 Contactor ZSK-778 1
4
6
1
11
7
12
13
3
9
8
5
5
6
5
10
2
ZSN-250
Thermostat
Silicon rubber
ZSK-764
Overheating
protector
Use only parts approved by the manufacturer!
FR
16
LIRE ATTENTIVEMENT LES CONSIGNES D’UTILISATION AVANT LA MISE EN SERVICE DE L’APPAREIL.
Avertissements
Ne pas utiliser le sauna pour y faire sécher du linge sous peine de provoquer un incendie ou d’en-
dommager les pièces électriques en raison de l’humidité excessive.
Se tenir éloigné des pierres et des parties métalliques du poêle. Elles risquent de provoquer des brûlures.
Ne pas projeter trop d’eau à la fois sur les pierres: la vapeur produite au contact des pierres est brû-
lante.
Cet appareil n’est pas destiné à être utilisé par des personnes (y compris les enfants) ayant des
handicaps physiques, sensoriels ou mentaux, ou un manque d’expérience, à moins qu’ils n’aient été
informés de la manière d’utiliser l’appareil par une personne responsable de leur sécurité. Les enfants
doivent être surveillés afin de s’assurer qu’ils ne jouent pas avec l’appareil.
Les enfants, les handicapés et les personnes affaiblies ou en mauvaise santé doivent être accompagnés
lors des séances de sauna.
Les parents doivent veiller à ce que les enfants ne s’approchent pas trop près du poêle.
Discuter avec un pédiatre de la participation éventuelle d’enfants en bas âge aux séances de sauna
(âge, température du sauna, durée des séances ?)
Toujours se déplacer avec la plus grande prudence, les bancs et le sol pouvant être glissants.
Ne pas fumer, consommer d’alcool ou faire de l’exercice dans le sauna.
Ne pas passer plus de 30 min de suite dans le sauna car une exposition excessive peut nuire à la
santé. Le sauna ne doit pas être utilisé comme test d’endurance !
Les personnes en mauvaise santé doivent consulter leur médecin avant d’utiliser le sauna !
Ne pas placer de matériau combustible au-dessus du poêle (serviettes, maillots de bain, seau ou louche
en bois) !
L’hyperthermie se produit lorsque la température interne du corps dépasse de plusieurs degrés la
température normale du corps (98,6 °F). Les symptômes d’hyperthermie incluent une hausse de la
température interne du corps, des vertiges, la léthargie, la somnolence et l’évanouissement.
Les effets de l’hyperthermie incluent :
A) l’insensibilité à la chaleur ;
B) l’indifférence au besoin de sortir de la cabine ;
C) l’inconscience du danger imminent ;
D) des lésions fatales chez les femmes enceintes ;
E) l’incapacité physique à sortir de la cabine ;
F) la perte de connaissance.
AVERTISSEMENT : La consommation d’alcool, de
drogues ou de médicaments peut augmenter
considérablement le risque d’hyperthermie mortelle.
Utiliser uniquement de l’eau propre du robinet
sur les pierres. Ne pas utiliser d’eau de piscine
ou de spa car cela risquerait de dégager du
chlore et d’endommager les résistances !
L’air marin et humide est susceptible d’avoir une
action corrosive sur les surfaces métalliques.
Ne videz pas le réservoir d'eau avant d'avoir
laissé le dispositif au repos pendant au moins
une heure.
Prenez garde, car la vapeur chaude peut
provoquer des brûlures.
En aucun cas ne placer dans le compartiment
réservé aux pierres ou même à proximité immé-
diate, des objets et des appareils qui pourraient
modifier la quantité et la direction de l’air circu-
lant à travers le poêle, ceci pourrait causer un
échauffement excessif des résistances et entraî-
ner un risque d’incendie sur les parois du sauna!
Fonction du poêle électrique :
Le poêle électrique HL est destiné à être utilisé dans un sauna familial bien isolé contre la chaleur. Il est
interdit d’utiliser le poêle à toute autre fin.
La période de garantie d’un poêle électrique HL est d’un an pour une utilisation familiale et de 3 mois pour
une utilisation communautaire. Veuillez lire attentivement les instructions avant d’utiliser le poêle.
IMPORTANT !
Ces instructions d’installation et d’utilisation sont destinées au propriétaire du sauna ou à la personne
répondant de l’entretien ainsi qu’à l’électricien réalisant l’installation du poêle.
Attention aux surfaces chaudes !
Ne pas utiliser le poêle sans pierres ou si les
pierres ont été empilées de façon incorrecte.
S’il est mal rempli, le compartiment à pierres
risque de provoquer des incendies.
Remplissez toujours le réservoir d'eau
avant utilisation !
Ne pas utiliser le poêle sans la trappe
d’entretien.
17
FR
1. MODE D’EMPLOI
1.1. Mise en place des pierres du poêle
L’empilement des pierres du poêle a un impact im-
portant sur le fonctionnement du poêle (figure 1).
Informations importantes concernant les pierres du
poêle :
Le diamètre des pierres doit se situer entre 2 et
4’’ (5 et 10 cm).
Utiliser uniquement des pierres angulaires
fendues prévues pour être utilisées dans un
poêle. La péridotite, l’olivine et la dolérite oli-
vine sont des pierres adaptées.
Ne jamais utiliser de « pierres » légères en
céramique poreuse ou en stéatite molle dans
le poêle. Elles n’absorbent pas suffisamment la
chaleur et peuvent endommager les résistances.
Dépoussiérer les pierres avant de les empiler
dans le poêle.
Lors de la mise en place des pierres :
Ne pas faire tomber de pierres dans le poêle.
Placer les pierres de manière éparse pour
veiller à ce que l’air puisse circuler entre elles.
Ne pas former de haute pile de pierres sur le poêle.
Aucun objet susceptible de modifier la quantité
ou la direction du flux d’air qui traverse le poêle
ne doit être placé à l’intérieur du compartiment
à pierres du poêle ni à proximité de ce dernier.
1.1.1. Maintenance
Étant données les variations importantes de tempé-
rature, les pierres du poêle se désintègrent au fur et
à mesure de leur utilisation.
Remettre les pierres en place au moins une fois par
an, voire plus si le sauna est utilisé fréquemment.
Dans le même temps, retirer tous les morceaux de
pierre de la partie inférieure du poêle et remplacer
toutes les pierres désintégrées par des neuves. Ain-
si, la capacité de chauffage du poêle reste optimale
et le risque de surchauffe est évité.
Prêter une attention particulière au tassement
progressif des pierres. S’assurer que les résis-
tances n’apparaissent pas avec le temps. Les pierres
se tassent plus rapidement deux mois après leur
empilement.
1.2. Chauffage du sauna
Pour éliminer les odeurs dégagées par le poêle et
les pierres lors de la première utilisation, veiller à
une bonne ventilation de la pièce du sauna.
Si la puissance du poêle est adaptée à la cabine
de sauna, un sauna correctement isolé atteint la
température adéquate en une heure environ (
2.3.). Les pierres du poêle chauffent généralement
à bonne température en même temps que le sau-
na. La température appropriée pour les séances de
sauna se situe entre 149–176 °F (65–80 °C).
Avant la mise en marche du poêle, vérifier
qu’aucun objet n’est posé dessus ou à
proximité.
1.2.1. Utilisation du poêle
Ce modèle fonctionne avec le centre de contrôle
séparé. Voir les instructions d’installation et mode
d’emploi du centre de contrôle.
1.2.2. Projection de l’eau sur les pierres
L’air du sauna devient sec en chauffant. Pour obtenir
une humidité convenable, il faut projeter de l’eau sur
les pierres brûlantes du poêle. La chaleur et la vapeur
produisent un effet différent d’une personne à l’autre
– en procédant à des essais, on peut trouver le niveau
de température et d’humidité qui convient le mieux.
Il est possible de générer une chaleur d’une na-
ture douce ou intense, selon ses souhaits, en choi-
sissant de verser de l’eau sur le devant du poêle ou
directement au-dessus des pierres.
La contenance de la louche utilisée ne doit
pas excéder 0,05 gal (0.2 litres). Ne pas pro-
jeter ou verser une quantité d’eau plus importante
en une seule fois. En effet, lors de l’évaporation,
l’excédent d’eau bouillante pourrait éclabousser les
personnes présentes dans le sauna. Veiller aussi à
ne pas projeter d’eau sur les pierres lorsque
quelqu’un se trouve à proximité du poêle, la vapeur
bouillante risquant de causer des brûlures.
Figure 1. Mise en place des pierres du poêle
FR
18
N’utiliser que de l’eau remplissant les exigences
de qualité de l’eau domestique (tableau 1). Pour aro-
matiser la vapeur d’eau, n’utiliser que des essences
prévues à cet effet. Suivre les consignes figurant
sur l’emballage.
1.3. Chauffage du sauna, avec vaporisateur
Avec le poêle Combi on peut chauffer le sauna
comme avec un poêle classique ou compléter cette
action par le dispositif de vaporisation du poêle.
Toujours remplir le réservoir d’eau avant l’usage!
La capacité d’eau du dispositif vaporisateur
est d’environ 5 l, ce qui suffit pour 2 heures
de fonctionnement continu du vaporisateur.
Le réservoir du vaporisateur ne doit être rempli
que lorsque le poêle est froid.
1.3.1. Remplissage du réservoir d´eau
Remplir le réservoir avec de l’eau domestique pure.
La capacité maximale du réservoir est d’environ 1,3
gal (5 litres). Figure 2.
Éteindre l’appareil avant d’ajouter de l’eau dans
l’évaporateur chaud.
Prenez garde, car la vapeur chaude peut
provoquer des brûlures.
1.3.2. Vidange du réservoir d’eau
Toujours vider l’eau du réservoir après utilisation
lorsque l’eau a refroidi. Cette mesure permet d’éli-
miner les impuretés qui se forment dans le réser-
voir par la suite de l’évaporation de l’eau.
1.3.3. Poêles Combi équipés d’un système
automatique de remplissage d’eau
Le réservoir d’eau des poêles Combi, qui sont équipés
d’un système automatique de remplissage d’eau, se
remplit automatiquement dès que le commutateur
(2) du générateur de vapeur est en position marche.
1.4. Emploi de parfums
Il est possible de parfumer l’eau du vaporisateur
à l’aide d’essences liquides ou en sachets. Les
essences liquides sont versées dans les bols en
pierre du vaporisateur. Placer les essences en
sachets sur la grille à vapeur.
Lors de l’utilisation d’essences, faire attention à
la vapeur chaude sortant du vaporisateur. Eviter
de rajouter de l’eau et des essences dans un
vaporisateur chaud.
Laver les bols en pierre à l’eau courante
relativement fréquemment.
1
2
Vidange du réservoir d’eau
Remplissage du réservoir d´eau
max.
min.
Remplissez toujours le réservoir d'eau avant utilisation !
Attention : l'eau
est très chaude !
Figure 2. Remplissage et vidange du réservoir d’eau
Tableau 1. Exigences en matière de qualité de l’eau
Propriétés de l’eau Effets Recommandations
Concentration d’humus Couleur, goût, précipités < 12 mg/l
Concentration en fer Couleur, odeur, goût, précipités < 0,2 mg/l
Concentration de manganèse (Mn) Couleur, goût, précipités <0,10 mg/l
Dureté : les substances les plus importantes sont
magnésium (Mg) et chaux, cest-à-dire calcium (Ca)
Précipité Mg: < 100 mg/l
Ca: < 100 mg/l
Eau contenant du chlorure Corrosion Cl: <100 mg/l
Eau chlorée Risque pour la santé Zakazana
Eau de mer Corrosion rapide Zakazana
Concentration d’arsenic et de radon Risque pour la santé Zakazana
19
FR
1.5. Séchage du sauna
Après l’utilisation du vaporisateur, il faut toujours
soigneusement sécher la pièce du sauna. Afin
d’accélerer le séchage, on peut laisser le poêle
branché et régler la ventilation du sauna au
maximum.
Si le poêle est utilisé pour le séchage, s’assurer
qu’il s’éteint effectivement après le délai préréglé.
1.6. Nettoyage du vaporisateur
Les impuretés comme le calcaire contenu dans l’eau
s’accumulent sur les parois du poêle. Pour enlever
le calcaire, utiliser un produit detartrant domestique
pour cafetières et se conformer aux instructions
d’utilisation du produit. Pour le nettoyage des parois
extérieures, se servir d’un chiffon humide. Lors du
nettoyage extérieur, l’interrupteur du vaporisateur
doit impérativement être en position OFF (éteint).
1.7. Conseils pour la séance de sauna
Commencer la séance de sauna en se lavant.
S’asseoir dans le sauna et profiter de la vapeur
aussi longtemps que cela reste agréable.
Oublier le stress et se détendre !
Le code des bonnes manières dans un sauna
préconise de ne pas déranger les autres par un
comportement bruyant.
Ne pas faire fuir les autres occupants en pro-
jetant une quantité excessive d’eau sur les
pierres.
Se rafraîchir la peau afin de la refroidir. Les
personnes en bonne santé peuvent profiter
d’une baignade rafraîchissante si cela est pos-
sible.
Après la séance de sauna, se laver.
1.8. Dépannage
Toutes les opérations d’entretien doivent
êtres réalisées par professionnel de la mainte-
nance agréé.
Si le vaporisateur ne fonctionne pas, vérifier les
points suivants:
le réservoir d’eau est suffisamment rempli
(voir le paragraphe 1.3.)
la sécurité-surchauffe ne s’est pas déclenchée
(le bouton de réinitialisation est au fond du
vaporisateur 3.10.)
l’humidité excessive du sauna
le thermostat est réglé sur la valeur maximale
de température
Vérifier que le capteur de thermostat du réser-
voir d’eau se trouve sur la résistance et que le
capteur de protection contre la surchauffe se
trouve sous la résistance (voir les instructions
d’installation relatives au centre de contrôle).
Le poêle ne chauffe pas.
Vérifier que les fusibles du poêle sont en bon état.
Vérifier que le câble de raccordement est
branché.
Vérifier que le centre de contrôle indique un
chiffre supérieur à la température du sauna.
S’assurer que les sécurités surchauffe soient
toujours en place. Figure 11.
Vérifier que le circuit électrique est fermé au
niveau du coupe-circuit. Le coupe-circuit doit
aussi être de la bonne taille.
La cabine de sauna chauffe doucement. L’eau
versée sur les pierres du poêle refroidit trop
rapidement.
Vérifier que les fusibles du poêle sont en bon
état.
Vérifier que toutes les résistances s’allument
lorsque le poêle est allumé.
Augmenter le réglage du thermostat.
Vérifier que le poêle est suffisamment puissant
( 2.3.).
Vérifier que la ventilation de la cabine de sauna
est adaptée ( 2.4.).
La cabine de sauna chauffe rapidement, mais la
température des pierres reste insuffisante. L’eau
versée sur les pierres passe à travers.
Vérifier que le poêle n’est pas trop puissant
(2.3.).
Vérifier que la ventilation de la cabine de sauna
est adaptée ( 2.4.).
Le panneau ou les autres matériaux proches du
poêle noircissent rapidement.
Vérifier que les distances de sécurité sont
respectées ( 3.2.).
Vérifier qu’aucune résistance n’est visible
derrière les pierres. Si les résistances sont
visibles, remettre les pierres en place de
manière à ce que les résistances soient
totalement couvertes ( 1.1.).
Voir également le paragraphe 2.1.2.
Une odeur se dégage du poêle.
Voir le paragraphe 1.2.
Lorsqu’il est chaud, le poêle peut accentuer
les odeurs présentes dans l’air mais qui ne
sont pas liées au sauna ni au poêle. Exemples :
peinture, colle, graisse, assaisonnements..
Le poêle émet du bruit.
Des détonations peuvent parfois se faire
entendre ; elles sont vraisemblablement dues
au craquement des pierres sous l’effet de la
chaleur.
La dilatation thermique des composants du
poêle peut entraîner l’émission de bruits lorsque
le poêle chauffe.
x 2
Figure 3. Installation de la grille de sécurité
FR
20
2.1. Isolation du sauna et matériaux muraux
Dans un sauna chauffé électriquement, les surfaces
murales massives qui accumulent la chaleur (brique,
émail, crépi ou équivalent) doivent être suffisamment
isolées pour permettre l’utilisation d’un poêle de puis-
sance raisonnable.
Un sauna est considéré bien isolé si la structure
des murs et du plafond comporte :
Une couche de laine isolante soigneusement
appliquée d’une épaisseur de 4’’ (100 mm)
minimum 2’’ (50 mm).
Un matériau pare-vapeur, par exemple un papier
aluminium, dont les joints sont soigneusement
rendus étanches, apposé de façon que la surface
brillante soit du côté intérieur du sauna.
Un espace de ventilation entre le revêtement
en lambris et le pare-vapeur de 0/4’’ (10 mm)
(recommandation).
Comme revêtement mural, un lambris d’une
épaisseur de 1/2’’ – 5/8’’ (12–16 mm) environ.
Un espace de ventilation de quelques millimètres
entre la partie supérieure du lambris mural et
celui du plafond.
Pour pouvoir utiliser un poêle de puissance rai-
sonnable, il peut être judicieux d’abaisser le pla-
fond, (hauteur minimale 75” (1900 mm)). Cela dimi-
nue le volume du sauna et permet de choisir un
poêle de puissance plus faible. L’abaissement du
plafond se fait en ajustant la charpente à la hauteur
désirée. L’espace vide formé par la charpente est
isolé (épaisseur de l’isolant : min. 4’’ (100 mm)) et
revêtu comme indiqué ci-dessus.
La chaleur ayant tendance à monter, la hauteur
recommandée entre le banc et le plafond est de
47’’ (1200 mm).
IMPORTANT ! La protection des murs ou du pla-
fond (par exemple au moyen d’un panneau agglo-
méré avec liant minéral directement installé) peut
provoquer une augmentation dangereuse de la tem-
pérature des murs ou du plafond.
2.1.1. Structure du sauna -
informations d’ordre général
CADRE
2” x 4” (50 x 100 mm), 16” (406 mm) o.c.
HAUTEUR DU PLAFOND
Hauteur max. 7’6” (2300 mm)
ISOLATION
Fibre de verre R11avec le pare-vapeur papier alu-
minium sur les murs et le plafond avec la surface
brillante du papier soit vers l’intérieur du sauna.
PANNEAU DE PLACOPLÂTRE
Se reporter à la réglementation locale. N’est géné-
ralement pas exigée dans le cadre d’une utilisation
domestique. Se reporter à la réglementation locale
en cas d’utilisation commerciale. Si un panneau de
Placoplâtre est installé, utiliser un fond de clouage
de 1’’ x 2’’ (25 x 50 mm) afin de faciliter la fixation
des planches des murs et du plafond.
REVÊTEMENT MURAL
Utilisez du bois séché au séchoir (avec une teneur en
humidité inférieure à 11 %).
BANCS
Utilisez du bois assorti. Placez les fixations en des-
sous afin d’éviter que les utilisateurs du sauna se
brûle.
PORTE
Doit s’ouvrir vers l’extérieur et être dépourvue de
serrure. Les types de fixations de porte pouvant être
utilisés sont les loquets magnétiques, les loquets
à friction, les ferme-portes à ressort ou à gravité
et autres.
LAMPE
Doit être étanche à la vapeur, montée au mur avec
un boîtier de retenue monté dans l’alignement du
revêtement mural intérieur. Elle doit être située à
6’’ (150 mm) du plafond au minimum et ne sur-
plomber ni les bancs ni le poêle. L’ampoule ne
devrait pas excéder les watts recommandés par le
fabricant de la lampe.
Important ! Aucune prise électrique n’est autorisée
dans le sauna. Si un haut-parleur est installé dans
le sauna, il ne doit pas être monté à plus de 3’’
(914 mm) du plancher et doit être éloigné du poêle
(consulter le fabricant pour tous renseignements sur
le calibrage).
2.1.2. Noircissement des murs du sauna
Avec le temps, il est tout à fait normal que les
surfaces en bois de la cabine de sauna noircissent.
Ce noircissement peut être accéléré par
la lumière du soleil
la chaleur du poêle
les agents de protection appliqués sur les
murs (les agents de protection présentent un
faible niveau de résistance à la chaleur)
2.2. Revêtement de sol du sauna
Du fait des importants changements de tempé-
rature, les pierres du poêle se détériorent et s’ef-
fritent avec le temps.
La vapeur d’eau débarrasse les pierres des par-
ticules et débris détachés en les entraînant vers
le sol. Afin d’éviter les inconvénients esthétiques
résultant de ces faits, il est conseillé d’utiliser au-
dessous et tout autour du poêle un revêtement de
sol de type minéral et des joints foncés.
2.3. Puissance du poêle
Lorsque le revêtement des murs et du plafond est
en lambris et que l’isolation se trouvant derrière est
suffisante pour éviter les pertes de chaleur vers les
matériaux des murs, la détermination de la puis-
sance du poêle se fait d’après le volume du sauna.
Se reporter au tableau 2.
Les murs d’un sauna en bois rond ou madriers
chauffent lentement ;
il faut donc, lors de la détermination de la puis-
sance du poêle, multiplier le volume par 1,5 et choi-
sir la puissance correspondant à ce volume corrigé.
2. LE SAUNA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

HARVIA HL Series Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues