1
Operating Instructions
Warnings for the safe use of this compressor are included in this manual.
Des mises en garde pour une utilisation en toute sécurité de ce compresseur
sont incluses dans ce manuel.
En este manual se incluyen avisos para el uso seguro de este compresor.
PC0967 Electric Air Compressor
PC0967 Issued June 25, 2003
Questions? Comments? call SENCO's toll-free Action-line: 1-800-543-4596 or e-mail: [email protected]
Senco Products, Inc.
8485 Broadwell Rd.
Cincinnati, OH 45244
© 2003 by Senco Products, Inc.
2
TABLE OF CONTENTS
INTRODUCTION ................................................................... 3
SAFETY ALER
T..................................................................... 3
INSPECTION .........................................................................
3
SAFETY
WARNINGS ............................................................ 4
ELECTRICAL ................................................................ 4
EXPLOSION OR FIRE.................................................. 5
BURSTING ...................................................................
5
BREATHING .................................................................
6
BURNS .........................................................................
6
FLYING OBJECTS........................................................
6
MOVING PARTS........................................................... 7
NEGLIGENCE ..............................................................
7
AIR COMPRESSOR DAMAGE..................................... 7
COMPRESSOR FEATURES .................................................
8
PREPARATION.................................................................... 10
INITIAL SET-UP ......................................................... 10
LOCATION.................................................................. 10
ELECTRICAL .............................................................. 10
OPERATION ........................................................................ 11
PRE-ST
ART CHECKLIST ........................................... 11
START-UP .................................................................. 11
SHUTDOWN .............................................................. 11
MAINTENANCE................................................................... 11
TROUBLESHOOTING ................................................... 12-14
SPECIFICATIONS ............................................................... 15
WARRANTY ........................................................................ 16
3
INTRODUCTION
Congratulations on the purchase of your new SENCO
®
Air Compressor! You can be assured your SENCO Air
Compressor was constructed with the highest level of precision and accuracy. Each component has been rigorously
tested by technicians to ensure the quality, endurance and performance of this air compressor.
This operator’s manual was compiled for your benefit. By reading and following the simple safety, installation and
operation, and maintenance steps described in this manual, you will receive years of troublefree
operation
from your new SENCO Air Compressor. . The contents of this manual are based on the latest product
information available at the time of publication. The manufacturer reserves the right to make changes in price,
color, materials equipment, specifications or models at any time without notice.
SAFETY ALERT!
A
DANGER, WARNING or CAUTION
safety warning will be surrounded by a ”SAFETY ALERT BOX”.
This box is used to designate and emphasize Safety Warnings that must be followed when operating this
air compressor. Accompanying the safety warnings are “Signal Words” which designate the degree or
level of hazard seriousness. The “Signal
Words” used in this manual are as follows:
DANGER:
Indicates an imminently hazardous situation which, if not avoided,
WILL result in
death or serious injury
.
WARNING:
Indicates a potentially hazardous situation which, if not avoided,
COULD result in
death or serious injury.
CAUTION:
Indicates a potentially hazardous situation which, if not avoided
MAY result in
minor or moderate injury or damage to the air
compressor
.
The symbols set to the left of this paragraph are “Safety Alert Symbols”.
These symbols are used to call attention to items or procedures that could
be dangerous to you or other persons using this equipment.
ALWAYS PROVIDE A COPY OF THIS MANUAL
TO ANYONE USING THIS EQUIPMENT. READ ALL
INSTRUCTIONS IN THIS MANUAL AND ANY INSTRUCTIONS SUPPLIED BY MANUFACTURERS OF
SUPPORTING EQUIPMENT BEFORE OPERATING THIS AIR COMPRESSOR AND ESPECIALLY POINT OUT
THE “SAFETY
WARNINGS” TO PREVENT THE POSSIBILITY OF PERSONAL INJURY TO THE OPERATOR.
INSPECTION
Unbox the air compressor and write in the serial number in the space provided below. Inspect for signs of obvious
or concealed freight damage. Be sure that all damaged parts are replaced and any mechanical problems are
corrected prior to the operation of the air compressor.
SERIAL NUMBER__________________________________________
If you have Questions or Comments call SENCOs
toll-free Action-line: 1-800-543-4596 or, e-mail:
toolprof@Senco.com
Please have the following information available for all service calls:
1. Model Number
2. Serial Number
3. Date and Place of Purchase
Senco, 8485 Broadwell Road, Cincinnati, OH 45244
4
POTENTIAL CONSEQUENCE
Serious injury or death could occur if
the air compressor is not properly
grounded.
Your air compressor is
powered by electricity and may cause
electric shock or electrocution if not
used properly
.
Electrical shock may occur from
electrical cord.
Electrical shock may occur if air
compressor is not operated properly.
Serious injury or death may occur if
electrical repairs are attempted by
unqualified persons.
PREVENTION
Make sure the air compressor is
plugged into a properly grounded
outlet which provides correct
voltage and adequate fuse
protection.
Check power cord for signs of
crushing, cutting or heat damage.
Replace faulty cord before use.
Keep all connections dry and off the
ground. Do not allow electrical
cords to lay in water or in such a
position where water could come in
contact with them. Do not touch
plug with wet hands.
Do not pull on the electrical cord to
disconnect from the outlet.
Never operate air compressor in
wet conditions or outdoors when it
is raining.
Never operate air compressor with
safety guards/covers removed or
damaged.
Any electrical wiring or repairs
performed on this air compressor
should be done by Authorized
Service Personnel in accordance
with National and Local electrical
codes.
Before opening any electrical
enclosure, always shut off the air
compressor, relieve pressure and
unplug the air compressor from the
power source. Allow air compressor
to cool down. Never assume the air
compressor is safe to work on just
because it is not operating. It could
restart at any time!
HAZARD
RISK OF
ELECTRIC SHOCK
OR
ELECTROCUTION
SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR
5
SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR
POTENTIAL CONSEQUENCE
Serious injury or death may occur from
normal electrical sparks in motor and
pressure switch.
Serious injury may occur if any air
compressor ventilation openings are
restricted, causing the air compressor
to overheat and start on fire.
Serious injury or death may occur from
an air tank explosion if air tanks are
not properly maintained.
Serious injury may occur from an air
compressor malfunction or exploding
accessories if incorrect system
components, attachments or
accessories are used.
HAZARD
RISK OF
EXPLOSION OR FIRE
RISK OF
BURSTING
PREVENTION
Always operate air compressor in a
well ventilated area free of
flammable vapors, combustible
dust, gases or other combustible
materials.
If spraying flammable material,
locate the air compressor at least
20 feet away from the spray area.
(An additional hose may be
required.)
Never place objects against or on
top of air compressor. Operate air
compressor at least 12 inches away
from any wall or obstruction that
would restrict proper ventilation.
Drain air tank daily or after each use
to prevent moisture buildup in the
air tank.
If air tank develops a leak, replace
the air tank immediately. Never
repair, weld or make modifications
to the air tank or its attachments.
Never make adjustments to the
factory set pressures.
Never exceed manufacturers
maximum allowable pressure rating
of attachments.
Because of extreme heat, do not
use plastic pipe or lead tin soldered
joints for a discharge line.
Never use air compressor to inflate
small, low pressure objects such as
toys.
6
POTENTIAL CONSEQUENCE
Serious injury or death could occur
from inhaling compressed air. The air
stream may contain carbon monoxide,
toxic vapors or solid particles.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides,
weed killers, etc. contain harmful
vapors and poisons.
Serious injury could occur from
touching exposed metal parts.
These areas can remain hot for some
time after the air compressor is
shutdown.
Soft tissue damage can occur from the
compressed air stream.
Serious injury can occur from loose
debris being propelled at a high speed
from the compressed air stream.
SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR
HAZARD
RISK TO
BREATHING
RISK OF
BURNS
RISK
OF FLYING
OBJECTS
PREVENTION
Never inhale air from the air
compressor either directly or from
a
breathing device connected to the air
compressor
.
Operate air compressor only in a well
ventilated area. Follow all safety
instructions provided with the
materials you are spraying. Use of a
respirator may be required when
working with some materials.
Never allow any part of your body or
other materials to make contact with
any exposed metal parts on the air
compressor
.
Always wear OSHA required “Z87”
safety glasses to shield the eyes
from flying debris.
Never point the air stream at any part
of your body, anyone else or animals.
Never leave pressurized air
compressor unattended. Shut off air
compressor and relieve pressure
before attempting maintenance,
attaching tools or accessories.
Always maintain a safe distance from
people and animals while operating
the air compressor.
Do not move the air compressor
while air tank is under pressure. Do
not attempt to move the air
compressor by pulling on the hose.
7
POTENTIAL CONSEQUENCE
Risk of bodily injury from moving parts.
This air compressor cycles
automatically when the pressure
switch is in the “On/Auto” position.
Risk of injury from negligent use.
Risk of major repair
.
SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR
RISK FROM
NEGLIGENCE
RISK
OF AIR COMPRESSOR
DAMAGE
HAZARD
RISK FROM
MOVING PARTS
PREVENTION
Always turn off air compressor when
not in use. Bleed pressure from the
air hose and unplug from electrical
outlet before performing
maintenance. All repairs to the air
compressor should be made by an
Authorized Service person. Never
assume the air compressor is safe
to work on just because it is not
operating. It could restart at any time!
Do not operate without protective
covers/guards. Replace damaged
covers/guards before using the air
compressor
.
Never allow children or adolescents
to operate this air compressor!
Stay alert-watch what you are doing.
Do not operate the air compressor
when fatigued or under the influence
of alcohol or drugs.
Know how to stop the air
compressor. Be thoroughly familiar
with controls.
Do not operate air compressor
without an air filter.
Do not operate air compressor in a
corrosive environment.
Always operate the air compressor
in a stable, secure position to prevent
air compressor from falling.
Follow all maintenance instructions
listed in this manual.
! SAVE THESE INSTRUCTIONS !
Fill with oil to level marked on
dipstick
8
COMPRESSOR FEATURES
1 Motor/Pressure Switch
2
3
4
Air Compressor Pump
5
Safety Relief
V
alve (lower tank)
6
7 Tank Pressure Gauge
8
Outlet Pressure Gauge
9
Pressure Regulator
Discharge Line
Ventilation Openings / Protective Shroud
Quick Disconnect
1
2
3
6
12
7
8
9
5
4
10
11
10 Air Filter
11 Oil Dipstick
12 Tank Drain
9
COMPRESSOR FEATURES
1) MOTOR/PRESSURE SWITCH: This switch is used to start or stop the air
compressor. Moving the switch to the Auto (On) position will provide automatic
power to the pressure switch which will allow the motor to start when the air tank
pressure is below the factory set cut-in pressure. When in the Start/ Stop Option,
the pressure switch stops the motor when the air tank pressure reaches the factor
set cut-out pressure. For safety purposes, this switch also has a pressure release
valve located on the side of the switch designed to automatically release compressed
air from the air compressor pump head and its discharge line when the air compressor
reaches cut-out pressure or is shut off.
This allows the motor to restart freely. Moving
the switch to the Off position will remove power from the pressure switch and stop
the air compressor.
2)
MOTOR THERMAL OVERLOAD: The electric motor has a thermal
overload protector. If the motor overheats for any reason, the thermal overload will
cut off power, thus preventing the motor from being damaged. Wait until the motor is
cool. Motor also has a magnetic breaker. Reset switch if it is tripped.
3) AIR INTAKE FILTER: This filter is designed to clean air coming into the pump. To
ensure the pump continually receives a clean, cool, dry air supply this filter must
always be clean and ventilation opening free from obstructions. The filter can be
removed for cleaning by using warm, soapy water. Rinse the filter and air dry.
4) AIR COMPRESSOR PUMP: To compress air, the piston moves up and down in
the cylinder. On the downstroke, air is drawn in through the air intake valve while
the exhaust valve remains closed. On the upstroke, air is compressed, the intake
valve closes and compressed air is forced out through the exhaust valve, into the
discharge line, through the check valve and into the air tank.
5) SAFETY RELIEF VA
LVE: This valve is designed to prevent system failures by
relieving pressure from the system when the compressed air reaches a predetermined
level. The valve is preset by the manufacturer and must not be modified in any way
.
To
verify the valve is working properly, pull on the ring. Air pressure should escape.
When the ring is released, it will reseat.
6) AIR TANK DRAIN VALVE: The drain valve is used to remove moisture from the air
tank(s) after the air compressor is shut off.
NEVER attempt to open the drain valve
when more than 10 PSI of air pressure is in the air tank! To open the drain valve,
turn the knob counterclockwise. Tilt tank to ensure that all condensation drains
through valve.
7) AIR TANK PRESSURE GAUGE: The air tank pressure gauge indicates the
reserve air pressure in the air tank (s).
8) OUTLET PRESSURE GAUGE: The outlet pressure gauge indicates the air
pressure available at the outlet side of the regulator. This pressure is controlled
by the regulator and is always less or equal to the air tank pressure.
9) PRESSURE REGULA
TOR: The air pressure coming from the air tank is
controlled by the regulator knob. Turn the pressure regulation knob clockwise to
increase discharge pressure, and counterclockwise to decrease discharge
pressure.
10) DISCHARGE LINE: Please note that the discharge line is very hot.
1
2
10
6
5
7
8
9
11
3
11) DIPSTICK: The dipstick will measure the amount of oil in the
pump. Oil level should be checked on a daily basis to ensure that it is
between the minimum and maximum notch. Air escaping from the vent
is normal.
10
PREPARATION
INITIAL SET-UP:
1.
Read safety warnings before setting-up air compressor
.
LOCATION:
CAUTION
In order to avoid damaging the air compressor, do not incline the air compressor
transversely or longitudinally more than 10°.
1. Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation.
Do not place air compressor in an area:
-where there is evidence of oil or gas leaks.
-where flammable gas vapors or materials may be present.
WARNING
Serious injury or death may occur if electrical sparks from motor and pressure switch
come in contact with flammable vapors, combustible dust, gases or other
combustible materials. When using the air compressor for spray painting, place the
air compressor as far away I from the work area as possible, using extra air hoses instead of
extension cords.
-where air temperatures fall below 32°F or exceed 104°F.
-where extremely dirty air or water could be drawn into the air compressor.
ELECTRICAL:
DANGER
Improper connection of the equipment-grounding conductor can result in a risk
of shock or electrocution. Check with a qualified electrician or service personnel
if you are in doubt as to whether the outlet is properly grounded. Do not use any type of
adapter with this product. If repair or replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade terminal. The wire with insulation having
an outer surface that is green with or without yellow stripes is the grounding wire.
WARNING
This product must be grounded. If there should be a malfunction or breakdown,
grounding
provides a path of least resistance for electric current to reduce the
risk of electric shock. This product is equipped with a cord having an equipment-
grounding conductor and a grounding type plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
1. SENCO® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and
overheating of the motor. Use of an additional air hose is recommended rather than an extension cord. If use of an
extension cord is unavoidable, it should be plugged into a GFCI found in circuit boxes or protected receptacles.
When using an extension cord, observe the following:
Cable Length
Wire Gauge
Up to 25 feet 12 AWG
Up to 100 feet 10 AWG
Up to 150 feet 8 AWG
Up to 250 feet 6 AWG
Use only 3-blade extension cords that have 3-blade grounding-type plugs and 3-slot cord connectors that will
accept the plug from the product. Use only extension cords having an electrical rating not less than the rating of
the product. Do not use damaged extension cords. Examine extension cord before using and replace if damaged.
Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp
edges. Always shut off the air compressor switch before removing the plug from the receptacle.
Ensure the oil level is above the minimum notch and below the maximum notch on the dipstick. If low, add
compressor
pump oil.
3.
2. Add entire contents of oil from enclosed bottle prior to starting compressor
11
OPERATION
PRE-START CHECKLIST:
1. Check oil level. Add if necessary.
2. Remove any moisture in the air compressor air tank. Remove excessive pressure with an air tool, then open
the air tank drain valve in the bottom of the air tank. Close tightly when drained.
WARNING: Risk of bodily injury. NEVER attempt to open the drain valve when
more than 10 PSI of air pressure is
in the air tank!
3. Make sure the air compressor Motor Switch is in the "OFF" position.
4.
Make sure all safety valves are working correctly.
5.
Make sure all guards and covers are in place and securely mounted.
START-UP:
1.
Ensure the lever on the pressure switch box is in the "OFF" position.
2.
Plug the power cord into a grounded outlet.
3. Move the lever on the pressure switch box to the "AUTO" position.
4. START/STOP OPTION:
Turn it completely clockwise to the fully closed position. This will allow the air compressor
to "START" building up pressure in the air tanks and "STOP" when correct pressure is achieved. When pressure
drops with usage, the air compressor will "START" building up pressure again.
5. Set pressure by adjusting the pressure regulator knob counterclockwise for less pressure and clockwise for
more pressure.
6.
If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting".
SHUTDOWN:
1. To
stop the air compressor, move the lever on the pressure switch box to the "OFF" position. NEVER stop the
air compressor by unplugging it from the power source. This could result in risk of electrocution.
2. Drain
air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve rings.
3. Once pressure
in the air tanks register under 10 pounds, open the drain valve under each air tank to drain any
moisture.
4. Allow
the air compressor to cool down.
5. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
Read the instruction manual before performing maintenance. The following procedures must be performed when
stopping the air compressor for maintenance or service.
1. Turn off air compressor.
WARNING: Never assume the air compressor is safe to work on just because it is not
operating. It could restart at any time!
2. Disconnect cord from main power supply.
3. Open
all drains.
4.
Wait for the air compressor to cool before starting service.
MAINTENANCE CHART
PROCEDURE DAILY WEEKLY MONTHLY 200 HOURS
Check pump oil level X
Oil leak inspection X
Drain condensation in air tank(s) X
Check for unusual noise/vibration X
Check for air leaks X
Inspect air filter X
Clean exterior of compressor X
Check safety relief valve X
Change pump oil* X
Replace air filter X
*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever
comes first. Recommended
non-detergent straight weights.
12
TROUBLESHOOTING
Symptom 1. Motor will not run or restart.
Power cord not plugged in.
Motor/Pressure switch in “OFF” position.
Motor thermal overload switch has
tripped.
Fuse blown or circuit breaker has tripped.
Wrong gauge wire or length of extension
cord.
Air tank pressure exceeds motor/
pressure switch “cut-in” pressure.
Pressure release valve on motor/
pressure switch has not unloaded pump
head pressure.
Defective motor, motor capacitor, motor/
pressure switch, or check valve.
Plug
cord into grounded outlet.
Move switch to “ON”
position.
Turn air compressor off, wait until motor is cool, then check
motor circuit breaker.
Replace
fuse or reset circuit breaker.
Check for proper fuse amperage.
Check
for low voltage conditions.
Disconnect any other electrical appliances from circuit or
operate air compressor on its own branch circuit.
Check chart on page #10 for proper gauge wire and cord length.
Motor
will start automatically when air tank pressure drops
below
“cut-in” pressure of motor/pressure switch.
Bleed
the line by moving the switch to the “Off” position.
Contact
Senco Customer Service.
PROBABLE CAUSE
Motor/Pressure switch does not shut off motor when
air compressor reaches “cut-out” pressure and safety
relief valve activates.
Air compressor is incorrectly sized.
PROBABLE CAUSE
Defective pilot valve, the check valve is stuck open.
REMEDY
Move the motor/pressure switch to the “Off” position. If
the motor doesn’t shut off, unplug the air compressor. If
the electrical contacts are welded together, replace the
pressure switch.
Limit the air pressure to the capacity of the air
compressor. Either use a smaller tool or a larger air
compressor
.
REMEDY
Remove, clean or replace.
Symptom 2. When in the Start/Stop option, motor runs continuously.
Symptom 3. Air continues to leak at motor/pressure switch release valve after motor stops.
13
PROBABLE CAUSE
Defective motor/pressure switch.
PROBABLE CAUSE
Possible defective safety relief valve.
Excessive air tank pressure.
PROBABLE CAUSE
Fittings are not tight enough.
PROBABLE CAUSE
Defective or rusted air tank.
PROBABLE CAUSE
Damaged inlet (reed) valve.
TROUBLESHOOTING
REMEDY
Replace.
REMEDY
Operate safety relief valve manually by pulling on ring.
If it still leaks, it should be replaced.
Defective motor/pressure switch. Replace.
REMEDY
Tighten fittings where air can be heard escaping. Check
fittings with soapy water solution. Do not overtighten.
REMEDY
Air tank must be replaced. Do not attempt to repair
air tank!
REMEDY
Contact SENCO Customer Service 888-222-8144.
Symptom 4. Air continues to leak at motor/pressure switch release valve while motor is running.
Symptom 5. Air leaks from safety relief valve.
Symptom 6. Air leaks at fittings.
Symptom 7. Air leak in air tank.
Symptom 8. Air blowing from inlet filter
.
PROBABLE CAUSE
Pressure regulator knob not turned to high enough
pressure or defective pressure regulator.
Restricted air intake filter.
Air leaks.
Air compressor is not large enough for air
requirement.
REMEDY
Adjust pressure regulator knob to proper setting or
replace.
Clean.
Check for leaks and repair.
Check the accessory air requirement. If it is higher than
the CFM or pressure supply of the air compressor, you
need a larger air compressor.
Symptom 9. Insufficient pressure at air tool or accessory.
14
TROUBLESHOOTING
PROBABLE CAUSE
Restricted air intake filter.
Defective (reed) valve.
REMEDY
Clean.
Drain air tank and measure pump up time. Compare to
specifications. If lower, remove pump head and inspect
valve plate, clean or replace.
Symptom 10. Air compressor not making enough air.
Symptom 11. Moisture in discharge air.
PROBABLE CAUSE
Condensation in air tank caused by high level
of atmospheric humidity or air compressor is
not run long enough.
REMEDY
Drain air tank after every use. Drain air tank more often
in humid weather and use an air line filter.
14
TROUBLESHOOTING
PROBABLE CAUSE
Restricted air intake filter.
Defective (reed) valve.
REMEDY
Clean.
Drain air tank and measure pump up time. Compare to
specifications. If lower, remove pump head and inspect
valve plate, clean or replace.
Symptom 10. Air compressor not making enough air.
Symptom 11. Moisture in discharge air.
PROBABLE CAUSE
Condensation in air tank caused by high level
of atmospheric humidity or air compressor is
not run long enough.
REMEDY
Drain air tank after every use. Drain air tank more often
in humid weather and use an air line filter.
15
SPECIFICATIONS
Model # PC0967
Motor
Horsepower 2
Voltage 115
Amperage 14
Hz. 60
Phase Single
RPM 3450
Compressor Pump
Number of Cylinders 1
Compression Stage 1
Lubrication Splash
Oil Type SENCO PC 0344
Crankcase Aluminum
Bearings Ball
Cylinder Aluminum/Steel Sleeve
Valves Reed-Single
Head Aluminum
Filter Canister
Motor/Pressure Switch Setting
Cut-out 125 PSI
Cut-in 95 PSI
Controls On/Off
Air tank
Capacity 4 gallon
Performance
CFM Air Displacement
9.2
CFM @ 90 PSI 4.8
Maximum Pressure 125 PSI
Pump-up Time: 0-125 PSI 46 sec.
Recovery Time: 95-125 PSI 12 seconds
Weight
Net 63 Ibs.
Dimensions
Basic LxWxH 19"x17"x16.5"
16
SENCO COMPRESSOR AND P
ARTS W
ARRANTY
This compressor has been designed and constructed using the highest standards of material and workmanship.
COMPRESSOR
WARRANTY:
The length of this guarantee is one year
from date of purchase by the original retail purchaser. During this period,
Senco Products, Inc., will repair or replace at Sencoís option, any original part or parts for the original retail purchaser. This will
be done free of charge, provided the parts are determined defective in materials or workmanship upon examination by a Senco
Authorized
Warranty Service Center, with the exceptions and exclusions described below. Any replacement part provided will
carry a warranty for the balance of the period of warranty applicable to the part it replaces. When repair or replacement of parts
or compressor is necessary, the original retail purchaser returns the complete compressor or part, with transportation prepaid,
to the nearest Senco Authorized Warranty Service Center, with purchase receipt or other positive proof that the part or compressor
is within the warranty period.
Senco warrants all parts (except those listed below) of your Senco air compressor to be free from defects in materials and
workmanship during the following periods:
1. For 1 year from date of original purchase:
Compressor Pump Pilot
Valve
Tank Assembly Plumbing
Flywheel Throttle Control
Power Cord
2. For 90 days from date of original purchase:
Pressure Gauge Pressure Relief
Valve Draincocks
Defective parts not subject to normal wear and tear will be repaired or replaced, at our (Sencoís) option, during warranty period.
In any event, reimbursement is limited to the purchase price paid.
EXCLUSIONS:
1. Engine/Motor is covered under separate warranty by its respective manufacturer and is subject to the terms set forth
therein.
2. Normal wear parts not covered under warranty:
Isolators Drive Belt
Air Filter
3. This warranty does not cover parts damaged due to normal wear,
misapplication, misuse, accidents, operation at other
than recommended speeds or voltage (electric units only), improper storage, or damages resulting during shipping.
4.
Deviation from operating instructions, specifications, and maintenance schedules.
5. Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by person(s) other than
a Senco Authorized Warranty Service Center.
6. The use of other than genuine Senco Repair Parts will void warranty.
This warranty is contingent upon proper use of the compressor by purchaser and does not cover:
(A) Abnormal conditions, accident, neglect, misuse or improper storage of the unit.
(B) Deviation from operating or maintenance instructions.
(C) Modifications not authorized by Senco.
(D) Repairs or maintenance (other than routine air tank draining and oil filter changes required by your operating
and maintenance manual) made by persons other than Senco or its authorized agents.
(E) Freight damage.
THIS
WARRANTY IS THE ONLY WARRANTY ON THIS COMPRESSOR, AND ALL OTHER WARRANTIES, WHETHER
ORAL, WRITTEN, EXPRESS, OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, THE IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE EXCLUDED. BUYERíS OR USERíS REMEDIES
ARE SOLELY AND EXCLUSIVELY AS STATED ABOVE. SENCO PRODUCTS, INC. SHALL IN NO EVENT BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR SPECIAL DAMAGES. IN NO EVENT, WHETHER AS A RESULT OF A
BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL SENCOíS LIABILITY
EXCEED THE PRICE OF THE COMPRESSOR WHICH HAS GIVEN RISE TO THE CLAIM OR LIABILITY. ANY LIABILITY
CONNECTED WITH THE USE OF THIS COMPRESSOR SHALL TERMINATE UPON THE EXPIRATION OF THE
WARRANTY
PERIOD SPECIFIED ABOVE.
Replacement of Compressor Due to Natural Disaster
Senco will also replace any compressor destroyed by an Act of God such as flood, earthquake, hurricane or other disaster
resulting only from the forces of nature. Such a claim will be honored provided that such original retail purchaser had previously
submitted a completed warranty registration card, and then submits proof of ownership and an acceptable statement describing
such Act of God documented by an insurance carrier, police department, or other official governmental source. To
obtain
instructions for filing a claim call 1-800-543-4596.
SENCO PRODUCTS, INC.
CINCINNATI, OHIO 45244-1611 USA
1
Notice technique d'utilisation
Des mises en garde pour une utilisation en toute sécurité de ce compresseur
sont incluses dans ce manual.
Compresseur d'aire électrique PC0967
PC0967 Issued June 25, 2003
Questions? Commentaires? appel gratuit de SENCO au 1-800-543-4596 ou courriel à [email protected]
Senco Products, Inc.
8485 Broadwell Rd.
Cincinnati, OH 45244
© 2003 by Senco Products, Inc.
2
TABLE DES MATIÈRES
INTRODUCTION ................................................................... 3
ALERTES POUR LA SÉCURITÉ
................................ 3
INSPECTION .........................................................................
3
MISES EN GARDE DE SÉCURITÉ
..............................
4
ÉLECTRICITÉ ...............................................................
4
EXPLOSION OU INCENDIE
.......................................
5
ÉCLATEMENT ...............................................................
5
INHALATION................................................................. 6
BRÛLURES
..................................................................
6
OBJETS PROJETÉS
...................................................
6
PIÈCES EN MOUVEMENT
.........................................
7
NÉGLIGENCE ..............................................................
7
DOMMAGES AU COMPRESSEUR ............................. 7
CARACTÉRISTIQUES DU COMPRESSEUR
........................ 8
PRÉPARATION
.................................................................... 10
MISE EN ŒUVRE INITIALE
.......................................
10
EMPLACEMENT
.........................................................
10
ALIMENTATION ÉLECTRIQUE
..................................
10
FONCTIONNEMENT ............................................................ 11
LISTE DE VÉRIFICATIONS PRÉLIMINAIRES
. ............
11
DÉMARRAGE
.............................................................
11
COUPURE .............................................................. 11
ENTRETIEN
.........................................................................
11
DÉPANNAGE
.................................................................
12-14
SPÉCIFICATIONS ............................................................... 15
GARANTIE
.......................................................................... 16
3
INTRODUCTION
DANGER:
INSPECTION
Félicitations pour votre achat de notre nouveau compresseur d’air SENCO
®
! Vous pouvez
être assuré que votre compresseur d’air SENCO a été construit avec le plus haut niveau de
précision et d’exactitude. Chaque composant a été rigoureusement testé par des techniciens
pour constituer la qualité, l’endurance et la performance de ce compresseur d’air.
Ce manuel d’utilisation a été composé pour vous servir. En lisant puis en appliquant les étapes
simples décrites dans de manuel de sécurisation, installation et fonctionnement, et entretien,
vous aurez des années de service sans souci pour votre nouveau compresseur à air SENCO.
Le contenu de ce manuel est basé sur les dernières informations produit disponibles au moment
de sa publication. Le constructeur se réserve le droit d’opérer des changements sur prix, couleur,
matériel et équipement, spécifications ou modèles, à tout moment et sans préavis.
ALERTES POUR LA SÉCURITÉ !
Une signalisation pour DANGER, AVERTISSEMENT ou ATTENTION pour la sécurité sera entouré d’un
encadrement d’alerte. Ce cadre est utilisé pour montrer et renforcer les mesures de sécurité qui doivent
être respectées pour faire fonctionner ce compresseur d’air. En accompagnement des mises en garde de
sécurité il y a les mots clés d’alerte qui donnent le degré de danger du risque. Les mots utilisés dans ce
manuel sont :
Indique une situation très dangereuse, qui si les mesures ne sont pas
prises ENTRAÎNERA une blessure sérieuse voire mortelle.
AVERTISSEMENT : Indique une situation potentiellement dangereuse, qui si les
mesures ne sont pas prises ENTRAÎNERAIT une blessure sérieuse voire mortelle.
ATTENTION : Indique une situation potentiellement dangereuse, qui si les mesures
ne sont pas prises POURRAIT ENTRAÎNER une blessure légère ou endommager le
compresseur d’air.
Les symboles placés à la gauche de ce paragraphe sont les symboles d’alerte de
sécurité, ils sont utilisés pour attirer l’attention sur des articles ou procédures qui
pourraient présenter un danger pour vous ou d’autres personnes utilisant cet
équipement.
FOURNISSEZ TOUJOURS UNE COPIE DE CE MANUEL À TOUTE PERSONNE QUI VA UTILISER CET ÉQUIPEMENT.
IL FAUT LIRE TOUTES LES INSTRUCTIONS DE CE MANUEL PLUS TOUTES LES INSTRUCTIONS FOURNIES PAR
LES FABRICANTS DES ÉQUIPEMENTS ANNEXES AVANT DE FAIRE FONCTIONNER LE COMPRESSEUR D’AIR, ET
PRÊTER UNE ATTENTION TOUTE PARTICULIÈRE AUX MISES EN GARDE DE SÉCURITÉ POUR ÉVITER LA
POSSIBILITÉ DE BLESSURES CORPORELLES POUR L’OPÉRATEUR.
Déballez le compresseur d’air et écrivez son numéro de série dans l’emplacement fourni plus bas. Inspectez pour
chercher des signes d’éventuels dommages évidents ou cachés venant du transport. Assurez-vous que toutes pièces
endommagées soient remplacées et que tout problème mécanique soit résolu avant de mettre le compresseur d’air en
marche.
NUMÉRO DE SÉRIE __________________________
Si vous avez des questions ou commentaires à transmettre, contactez SENCO par appel sans frais au 1-800-222-8144 ou
en envoyant un message électronique à toolproof@Senco.com
Veuillez avoir sous la main ces informations en cas d’appel pour n’importe quel service
:
1. Référence de modèle
2. Numéro de série
3. Date et lieu d’achat
Senco, 8485 Broadwell Road, Cincinnati, OH 45244, USA
4
CONSEQUENCES POTENTIELLES
PREVENTION
DANGER
RISQUE DE
COMMOTION ÉLECTRIQUE
OU D’ÉLECTROCUTION
LISEZ TOUTES LES MISES EN GARDE DE SÉCURITÉ AVANT D’UTILISER LE
COMPRESSEUR D’AIR
MISES EN GARDE DE SÉCURITÉ
Des blessures graves ou
mortelles peuvent arriver si le
compresseur n’est pas mis à la
terre de façon convenable. Votre
compresseur d’air est alimenté de
l’électricité et cela peut provoquer
une commotion électrique ou une
électrocution si l’utilisation n’est
pas correcte.
Une commotion électrique peut
venir du cordon secteur.
Une commotion électrique peut
arriver si le compresseur n’est
pas utilisé correctement.
Des blessures graves ou
mortelles peuvent arriver si des
réparations électriques sont
tentées par des personnes non
qualifiées.
Assurez-vous que compresseur d’air est
bien branché sur une prise secteur
convenablement reliée à la terre, qui
fournit la tension correcte, et qui est
protégée en amont par fusible ou
disjoncteur.
Vérifiez le cordon secteur pour y déceler
des signes d’écrasement, de coupure ou
de brûlure. Remplacez le cordon s’il est
abîmé avant toute nouvelle utilisation.
Gardez toutes les connexions au sec et
ne reposant pas par terre. Ne laissez pas
le cordon secteur traîner dans l’eau ou
dans une position telle que de l’eau
puisse venir à son contact. Ne touchez
pas la fiche secteur avec des mains
mouillées.
Ne tirez pas sur le cordon secteur pour
débrancher la fiche de la prise murale.
Ne faites jamais fonctionner le
compresseur d’air dans des conditions
d’humidité ou à l’extérieur quand il pleut.
Ne faites jamais fonctionner le
compresseur d’air avec ses couvercles
et protections de sécurité enlevés.
Tout câblage ou dépannage électrique
effectué sur le compresseur d’air doit
être confié à un personnel de dépannage
agréé, en conformité avec les
réglementations électriques locales et
nationales.
Avant d’ouvrir toute partie électrique
fermée, arrêtez toujours le compresseur
d’air, faites chuter la pression et
débranchez l’appareil de sa prise
secteur. Laissez le compresseur d’air
refroidir. Ne présumez jamais que vous
pouvez intervenir en sécurité sur le
compresseur d’air juste parce qu’il ne
tourne pas. Il pourrait redémarrer
inopinément!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Senco Air Compressor PC0967 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
Ce manuel convient également à