HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
OTL Report No. 116-F-36-5
B-VENT
MPB-33/35/40/45 SERIES
MODELS
A French manual is available upon request. Order P/N 875,031CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 875,031CF.
Millivolt Models
P/N 875,031M REV. A 02/2006
B-VENT GAS FIREPLACES
MPB3328CNM
MPB3328CPM
MPB3530CNM
MPB3530CPM
MPB4035CNM
MPB4540CNM
MPB3328CNE
MPB3530CNE MPB4035CNE
MPB4540CNE
Electronic Models
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
infl ammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bati-
ment où vous vous trouvez.
Evacuez la piéce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournis-
seur de gaz.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell
gas:
DO NOT light any appliance.
DO NOT touch any electrical switches.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by a
qualifi ed installer, service agency or gas supplier.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
WARNINGS
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
If small children are present in the home, it is
recommended that this appliance be fi tted with
a screen door or screen panel kit. See Page 17
for ordering information.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
2NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CONGRATULATIONS!
In selecting this Lennox B-Vent Gas Appliance you have chosen the fi nest and most
dependable fi replace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fi replace. Welcome to a Family of tens of thousands of satisfi ed Lennox
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your Lennox product.
INTRODUCTION
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas Code,
ANSI Z223.1 (NFPA 54). (In Canada, the current
CAN/CGA B149 installation code). Electrical
wiring must comply with local codes. In the
absence of local codes, installation must be in
accordance with the National Electrical Code,
NFPA 70 - (latest edition). (In Canada, the current
CSA C22.1 Canadian Electric Code).
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
TABLE OF CONTENTS
Introduction ......................................Page 2
General Information ..........................Page 2
Operation/Care of Your Appliance .....Page 3
Variable Flame Adjustment ................Page 4
Outside Combustion Air Control .......Page 5
Manual Limit Switch .........................Page 5
Maintenance Schedule ......................Page 6
Maintenance ......................................Page 7
Front Glass Enclosure Panel,
Removal and Installation ...............Page 7
Burner Adjustments ..........................Page 8
Millivolt Appliance Checkout .............Page 8
Electronic Appliance Checkout ..........Page 8
Logs, Rockwool, Vermiculite &
Volcanic Stone Placement .............Page 9
Wiring Diagrams ...............................Page 14
Warranty ...........................................Page 14
Replacement Parts ............................Page 14
Product Reference Information .........Page 14
Accessory Components ....................Page 15
Lighting Instructions – Millivolt ........Page 18
Lighting Instructions – Electronic .....Page 20
Troubleshooting Guide – Millivolt .....Page 22
Troubleshooting Guide – Electronic ..Page 22
Replacement Parts List .....................Page 24
The millivolt appliances are designed to operate
on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, effi cient operation. External
electrical power is required to operate the
optional electrically powered components, if
installed. Electrical power must be wired during
appliance installation.
The electronic appliances are designed to
operate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, effi cient operation. External electrical
power is required to operate these units.
These appliances comply with National Safety
Standards and are tested and listed by OMNI-
Test Laboratories, Inc. (Report No. 116-F-__-__)
to ANSI Z21.50 (in Canada, CSA 2.22), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fi replaces.
GENERAL INFORMATION
Note: Installation and repair should be
performed by a qualifi ed service person. The
appliance should be inspected annually by a
qualifi ed professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating air
passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instructions
d'installation et d'utilisation qui accompagnent
l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffi c and away from furniture
and draperies. Locate furniture and window
coverings accordingly.
Millivolt Models with
Manually-Modulated Gas Valve
Natural Gas Propane Gas
Model Input Rate
(BTU/HR) Input Rate
(BTU/HR)
MPB3328 13,500 to 17,500 13,500 to 17,500
MPB3530 16,000 to 20,000 16,500 to 20,000
MPB4035 24,000 to 30,000 22,300 to 28,000
MPB4540 24,750 to 31,000 23,000 to 29,000
Table 1
Electronic Models -
Electronic models have a fi xed rate gas valve.
Input of electronic models is shown in Table 2:
Electronic Models with
Fixed-Rate Gas Valve
Natural Gas Propane Gas
Model Input Rate
(BTU/HR) Input Rate
(BTU/HR)
MPB3328 17,500 17,500
MPB3530 20,000 20,000
MPB4035 30,000 28,000
MPB4540 31,000 29,000
Table 2
These appliances are designed to operate on
natural or propane gas only.
Input of millivolt models is variable. These rates
are shown in Table 1:
Maximum manifold pressure is 3.5 in. w.c. (0.87
kPa) for natural gas and 10 in. w.c. (2.49 kPa)
for LP/Propane gas.
Do not use these appliances if any part has been
under water. Immediately call a qualifi ed, profes-
sional service technician to inspect the appliance
and to replace any parts of the control system and
any gas control which have been under water.
Table 3 shows the units' orifi ce size for the
elevations indicated.
Burner Orifi ce Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Models NaturalGas
drill size (inches) Propane Gas
drill size (inches)
MPB-3328 #47 (.0785") 1.2mm (.048")
MPB-3530 #44 (.086") #55 (.052")
MPB-4035 #37 (.104") 1/16"
(.0625")
MPB-4540 #36 (.1065") #52
(.0635")
Table 3
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage. Refer to this manual. For
assistance or additional information
consult a qualifi ed installer, service
agency or the gas supplier.
WARNING
These fi replaces are vented deco-
rative gas appliances. Do not burn
wood or other material in these
appliances.
3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifi é pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'leau.
Test gauge connections are provided on the front
of the millivolt gas control valve (identifi ed OUT
for the manifold side and IN for inlet pressure. A
1/8" NPT test gauge connection is provided on the
electronic gas control valve adjacent to the outlet
to the main burner.
Minimum inlet gas pressure to these appliances is
5.0 inches water column (1.24 kPa) for natural gas
and 11 inches water column (2.74 kPa) for propane
for the purpose of input adjustment.
Maximum inlet gas supply pressure to these appli-
ances is 10.5 inches water column (2.61 kPa) for
natural gas and 13.0 inches water column (3.23
kPa) for propane.
The appliance must be isolated from the gas supply
piping system (by closing its individual manual
shut-off valve) during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at pressures in excess of 1/2 psig (3.5 kPa).
These appliances must not be connected to a
chimney or fl ue serving a separate solid fuel
burning appliance.
Any safety guard or screen removed for servicing
the appliance must be replaced prior to operating
the appliance.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the fl u
with headaches, dizziness and/or nausea. If you
have these signs, obtain fresh air immediately.
Turn off the gas supply to the appliance and have
it serviced by a qualifi ed professional, as it may
not be operating correctly.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled through a
remotely located optional wall switch. Separate
switches may provide independent control for
the remote controlled fi replace operation (op-
tional equipment).
In lieu of remote or remote wall switch operation,
the appliance must be operated directly through
the controls located on the front of the valve
located within the control compartment which is
located behind the control compartment access
panel below the appliance front glass enclosure
panel. See Figure 1.
Gas Controls/Control Compartment
Access
The gas controls can be found behind the control
compartment access panel. To open the control
compartment access panel, actuate the spring
loaded magnetic catches securing the panel.
First, gently depress the upper right top corner
of the panel until the magnet catch "pops" the
door free. Then, gently pulling the panel forward,
disengage the left magnet catch and allow the
panel to swing down to open.
Operation of millivolt and electronic gas control
systems are different. Before lighting and op-
erating your appliance determine if you have a
millivolt or electronic appliance. See Figure 1
for access to the control compartment.
Millivolt appliances will be fi tted with the gas
control valve shown in Figure 3 on Page 4.
Appliances with electronic systems will be fi t-
ted with the electronic valve shown in Figure
2 on Page 4.
Familiarize yourself with the gas control valve
that your appliance uses.
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found on Page 18 (English)
and Page 19 (French). Millivolt appliance
lighting instructions may also be found on the
pull-out lighting instruction labels attached to
the gas control valve. Refer to Figure 3 on Page
4 for the location of the piezo Igniter.
Millivolt appliances may be fi tted with an optional
burner ON/OFF Rocker Switch. The optional ON/
OFF Rocker switch will be installed in the bracket
just beneath the gas control valve. Once the pilot
is lit, the ON/OFF rocker switch will control the
appliance ON/OFF operation. To operate: Toggle
the switch between its ON and OFF positions.
Figure 1
Piezo Igniter
Millivolt
Gas Valve
Control
Compartment
Access Panel
WARNING
B-Vent appliances are not designed
to operate in negatively pressured
environments (pressure within the
home is less than pressures outside).
Significant negatively pressured
environments caused by weather,
home design, or other devices may
impact the operation of these appli-
ances. Negative pressures may result
in poor fl ame appearance, sooting,
damage to property and/or severe
personal injury. Do not operate these
appliances in negatively pressured
environments.
WARNING
Failure to comply with the installa-
tion and operating instructions pro-
vided in this document will result in
an improperly installed and operat-
ing appliance, voiding its warranty.
Any change to this appliance and/or
its operating controls is dangerous.
Improper installation or use of this
appliance can cause serious injury
or death form fi re, burns, explosion
or carbon monoxide poisoning.
WARNING
Children and adults should be
alerted to the hazards of high sur-
face temperatures. Use caution
around the appliance to avoid burns
or clothing ignition. Young children
should be carefully supervised
when they are in the same room
as the appliance.
AVERTISSEMENT
Surveiller les enfants. Garder les
vêtements, les meubles, l'essence
ou autres liquides à vapeur infl am-
mables lin de l'appareil.
WARNING
Do not place clothing or other fl am-
mable materials on or near this
appliance.
4NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Variable Flame Height Adjustment
( Millivolt Appliances only)
1. All Millivolt appliances are equipped with
a variable gas control valve. Flame height for
these models may be adjusted through a range
between fi xed low and high settings, alternately,
while the appliance is in operation. Adjust
the fl ame height as desired after lighting the
appliance by rotating the variable adjustment
control knob located on the front of the valve
(refer to Figure 3).
2. When lit for the fi rst time, this appliance will
emit a slight odor for an hour or two. This is due
to the “burn-in” of internal paints and lubricants
used in the manufacturing process.
Electronic Appliances -
To light electronic appliances refer to the detailed
lighting instructions found in both English and
French on Pages 20 and 21 of these instruc-
tions respectively. Electronic appliance lighting
instructions may also be found on the pull out
lighting instruction labels attached to the gas
control valve. If your electronic appliance is
equipped with an optional remote wall switch
or remote control kit the appliance main burner
may be turned on and off with the wall switch
or remote control.
If your electronic appliance is not equipped
with a wall switch or remote control, the main
burner must be turned off and on with the gas
control switch. Toggle the switch from ON to
OFF to operate the main burner .
Honeywell Electronic Gas Valve
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
etc. It is important that control compartments,
burners and circulating air passageways of the
appliance be kept clean.
4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-lighting,
refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel
located on the fl oor of the appliance.
5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other fl ammable liquids.
Figure 2
Figure 3
6. Remember, Millivolt appliances have a
continuous burning pilot fl ame. Exercise cau-
tion when using products with combustible
vapors.
7. Clean the front glass enclosure only when
necessary. Wipe surface with clean, dampened,
soft cloth. Follow with dry, soft towel as desired.
Take care not to scratch the glass surface.
SIT Millivolt Gas Valve
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall switch
or remote control.
H
I
L
O
W
HTPT
HT
P
T
P
I
L
O
T
P
I
L
O
T
O
N
t
i
O
F
F
Variable Flame Height Adjustment
Manifold Pressure Port
Inlet Pressure Port
Main Gas
Control Knob
Piezo Igniter
IN OUT
Piezo Igniter
Optional Burner ON/OFF Rocker Switch Location
(One of Two Places)
ON/OFF Switch
Electronic
Gas Control
Valve
Inlet
Pressure
Port
Manifold Pressure Port
F
FO
NI
I
S
P
N
O
L
OR
TN
O
C
GI NT
IER
WARNING
Do not use abrasive cleaners. Never
clean the glass when it is hot.
CAUTION
Do not attempt to touch the front
enclosure glass with your hands
while the fi replace is in use.
5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Outside Combustion Air Controls
Many appliances are equipped, when installed,
with an outside (make-up air) vent system that
is designed to provide the appliance with outside
make-up air for combustion when in operation.
The combustion air control lever for the outside
air system is standard on all appliances but
should not be operated if the complete system
is not installed. Refer to Figure 4. When the
complete outside air vent system is installed,
the installer will remove the securing screw from
the combustion air control lever located on the
left side of the fi replace bottom opening.
If the securing screw has not been removed
and you have reason to believe that you have
a complete outside air system, contact your
distributor to have your appliance inspected for
the presence of the complete system. DO NOT
assume that you have this system in place.
Combustion Air Control Lever
and Securing Screw Location
Figure 4
To open the outside air shutter, open the bottom
control access panel, reach into control com-
partment and pull the combustion air control
lever all the way out. The outside air shutter
should be fully open when the fi replace is in
use and completely closed when the fi replace
is not being used. Closing it when not in use
will prevent outside cold air from entering the
dwelling.
Step 13. Spillage Test and Safety Limit
Switch Operation
Spillage Test
After appliance installation, perform this spill-
age test to verify that proper venting conditions
exist:
1 - Place unit in its normally-operated condi-
tion, that is, with the glass enclosure panel
in place.
2 - Close all doors and windows in the room.
Turn on all exhaust fans in the house.
3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by holding
a smoke producing device within an inch
of one edge (side edge, not top or bottom
edge) of the glass enclosure panel. The
smoke should be drawn toward the edge
of the glass enclosure panel. Continue the
test by moving the smoke producing device
along the entire length of both side-edges
of the glass door.
6 - If the smoke is not drawn towards the
edges of the glass door turn off the
appliance and call a qualifi ed service
technican.
Manually-Reset Safety Limit Switch
This appliance is equipped with a manually-reset
blocked fl ue safety limit switch. Refer to Figure
5 on Page 7 for its location. If, during appliance
operation, the fl ame goes out (independently of
the burner on/off wall switch), it may be due to
the operation of this safety limit switch. First
allow the appliance to cool. Remove top louver
panel. Then reset the safety limit switch by
pushing the red reset button, located between
the wire terminals, on the back of the switch.
See Detail A of Figure 5 for location.
The appliance should then relight and remain
lit. Reinstall top louver panel. If the appliance
does not relight, turn off the appliance and call
for a qualifi ed service technician.
To replace the blocked fl ue safety limit
switch refer to Figure 5 on Page 7 (Details
B and C):
NOTE - This procedure should only be performed
by a qualifi ed service technician.
Important - Turn electrical power off before
beginning this procedure.
1 - Lower the bottom control compartment
access panel. Remove the glass enclosure
panel: open the latch (located in the center
of the unit front opening, under the fi rebox
oor) securing the glass enclosure panel.
Remove the panel by tilting it outward at
the bottom and lifting it up. Set the door
aside protecting it from inadvertent dam-
age. See Figure 6 on Page 7.
2 - Remove the lintel securing screws (3) and
then remove the lintel. One of the lintel
cabinet top holes is shown in Figure 5
(Detail B).
3 - Remove the scoop securing screws (3)
and then remove the scoop. See Figure
5 (Detail B).
4 - Remove the safety switch bracket securing
screws (2), and pull the switch/bracket
assembly, with low voltage wires attached,
through the side panel slot into the fi rebox.
See Figure 5 (Detail C).
5 - Replace the switch.
6 - Reinstall the switch/bracket assembly.
7 - Reinstall the scoop and lintel.
8 - Reinstall the glass enclosure panel.
9 - Raise the bottom control compartment
access panel.
10 - The appliance should then relight and
remain lit. If this does not occur, check
unit for a blocked fl ue condition.
Outside Air Control Lever
Outside Air Control Lever
Securing Screw
Air Shutter in Closed Position
Outside Air Control Lever
Securing Screw Removed
Air Shutter in Open Position
Outside Air Control Lever
WARNING
Do not operate the shutoff lever
unless a complete outside combus-
tion air system has been installed
with your appliance.
6NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Inspecting/Cleaning Burner, Logs
and Controls
Qualifi ed Service Technician Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fi replace logs and
burner area.
Check Flame Patterns and Flame
Height
Qualifi ed Service Technician Refer to Figure 10 (MPB-3328), Figure 11 (MPB-3530) or Figure
12 (MPB-4035 & MPB-4540) on Page 9 and verify the fl ame
pattern and height displayed by the appliance conforms to the
picture. Flames must not impinge on the logs.
Inspecting/Cleaning Pilot and Burner Qualifi ed Service Technician Refer to Figures8 or 9 on Page 8. Remove any surface build-up
on pilot and burner assembly. Wipe the pilot nozzles, igniter/
ame rod and hood. Ensure the pilot fl ame engulfs the fl ame
sensor as shown.
Checking Vent System Qualifi ed Service Technician Inspect the vent system at the top and at the base (within the
rebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components.
Appliance Checkout Qualifi ed Service Technician Perform the appropriate appliance checkout procedure detailed
in this manual.
Replacing Rockwool Ember Materials Homeowner/Qualifi ed Service
Technician
Remove old ember materials (rockwool) and vacuum the
ember placement area. Place new embers as described on
Pages 9-13.
MAINTENANCE SCHEDULE - Annually (Before the onset of the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Cleaning Firebox Interior Homeowner Carefully remove logs, embers (rockwool), and volcanic stone.
Vacuum out interior of the fi rebox. Clean fi rebox walls. Replace
logs, embers (rockwool) and volcanic stone as detailed in this
manual (see Pages 9-13 ).
Check Flame Patterns and Flame
Height
Homeowner Refer to Figure 10 (MPB-3328), Figure 11 (MPB-3530) or Figure
12 (MPB-4035 & MPB-4540) on Page 9 and verify the fl ame
pattern and height displayed by the appliance conforms to the
picture. Flames must not impinge on the logs.
Checking Vent System Homeowner Inspect the vent system at the top and at the base (within the
rebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.
Cleaning Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS
WHILE HOT.
MAINTENANCE SCHEDULE - Periodically (After the Burning Season)
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
To install the front glass enclosure panel,
proceed as follows:
1. Retrieve the glass door frame. Visually
inspect the gasket on the backside of the
panel. The gasket surface must be clean,
free of irregularities and seated fi rmly.
2. Position the door frame in front of the fi rebox
opening and engage the top fl ange over the
lip at the top of the fi rebox opening.
3. Swing the door down and back. Ensure the
gasket seats evenly as the door draws shut.
Engage the Vee-fl ange at the bottom of the
door with the latch and close the latch to
secure the door.
4. Reinstall the top louver assembly or radiant
panel.
These appliances are designed to operate only
with the front glass enclosure panel properly
installed. Generally, the glass enclosure panel
should not be removed except to gain access
to the components within the fi rebox, and the
appliance may only be operated without the
front glass enclosure panel in place for very
brief periods of time during initial appliance
checkout and adjustment.
During this appliance checkout and adjust-
ment period, a potential safety hazard exists
- EXERCISE EXTREME CAUTION to prevent
the occurrence of any burn injuries from the
exposed fl ames or hot surfaces. Also note,
that while the front glass enclosure panel is
removed, the fl ame appearance will appear to
be smaller than normal.
Refer to Figure 6 and remove the front glass
enclosure panel as follows:
1. Remove the top louver assembly or radiant
panel.
2. Open the hinged drop-down control compart-
ment access panel.
3. Locate the latch at the top of the control
compartment and disengage it from the door
frame bottom Vee-fl ange, pulling down on its
handle to open it.
4. Swing the bottom of the door out and raise
it slightly to lift the top fl ange of the door frame
away from the appliance.
Figure 6
Maintenance
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualifi ed service technician.
However, more frequent periodic inspections
and cleanings should be performed by the ho-
meowner. Homeowner must contact a qualifi ed
service technician at once if any abnormal
condition is observed.
Refer to the maintenance schedule for main-
tenance tasks, procedures, periodicity and
by whom they should be performed. Always
verify proper operation of the appliance after
servicing.
IMPORTANT: TURN OFF GAS AND ANY
ELECTRICAL POWER BEFORE SERVICING
THE APPLIANCE.
Front Glass Enclosure Panel, Removal
and Installation.
Figure 5
Blocked Flue Safety Limit Location
Inside View of Firebox -
Top/Right Side Intersection
Detail A
Detail C
Detail B
Scoop
Scoop Securing Screws
Fire Box Top
Lintel Securing Screw
Hole in Cabinet Top
Fire Box Top
Limit
Limit/Bracket
Securing Screws
Lintel Securing-Scre
w
Hole in Cabinet Top
Wire
Termianls
Back Of
Limit
Switch
Cabinet
Corner
Door
Frame
Latch Glass Door
Firebox Floor
Bottom Vee-flange
Door Frame
Top Flange
Door Frame
IMPORTANT
The glass door of this appliance must
only be replaced as a complete unit as
provided by the manufacturer. Do not
attempt to replace broken, cracked
or chipped glass separately.
WARNING
Never operate the appliance with-
out the glass enclosure panel in
place and secure. Do not operate
appliance with the FRONT glass
panel cracked, broken or missing.
Replacement panels are available
through your local LENNOX Dealer
and must be installed by a licensed
or qualifi ed service technician.
WARNING
Handle the glass with extreme care!
Tempered glass is susceptible to
damage (scratches, for example)
Handle glass door (glass enclosure
panel) gently while reinstalling it.
WARNING
Do not attempt to substitute the mate-
rials used on this door, or replace
cracked or broken glass with any
materials other than those provided
by the appliance manufacturer.
WARNING
Turn off gas and electrical power
before servicing the appliance.
8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Electronic Appliance Checkout
To light the burner, refer to the lighting instruc-
tions on Pages20 and 21. Ensure the igniter
lights the pilot. The pilot fl ame should engulf
the fl ame sensor as shown in Figure 9.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, fi rst refer
to the trouble shooting guide in this manual.
If problem persists, contact your Lennox
distributor.
SIT Millivolt Appliance Checkout
The pilot fl ame should be steady, not lifting
or fl oating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" min (tip) of the
quick drop out thermocouple should be engulfed
in the pilot fl ame. The fl ame should project 1"
(25 mm) beyond the hood at all three ports
(Figure 8).
To light the burner, refer to the lighting instruc-
tions on Pages 18 and 19.
Figure 9
Burner Adjustments
Note - The air shutter for the burner primary
air opening is factory-set. Do not adjust the
factory-set position. The factory-set position
is shown in Figure 7.
Figure 7
Burner Air Shutter Adjustment
3/8" to 1/2"
(9 -13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
Proper Flame
Adjustment
Pilot
Nozzels
ELECTRONIC PILOT ASSEMBLY
Proper Pilot Flame Appearance
Figure 8
Thermocouple
Thermopile
Pilot
Nozzels
SIT MILLIVOLT PILOT ASSEMBLY
3/8" Min.
(9 mm)
Igniter Rod
Hood
Proper Pilot Flame Appearance
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model Natural
Gas
Propane
Gas
MPB-3328 Fully Closed 3/16"
(4.76 mm)
MPB-3530 Fully Closed 3/16"
(4.76 mm)
MPB-4035 Fully Closed 3/16"
(4.76 mm)
MPB-4540 Fully Closed 3/16"
(4.76 mm)
Air Shutter
Venturi
Setscrew - Factory Located in the
Natural Gas Position; Relocate Set
Screw for LP/Propane Gas in the
Alternate Position. See Table for
Air Shutter Openings for these
Setscrew Locations.
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 10
Figure 11
Figure 12
Burner Flame Appearance - Model MPB-3328
Burner Flame Appearance - Model MPB-3530
Burner Flame Appearance - Model MPB-4035 & MPB-4540
Initial Installation Considerations
The packaged logs are located within the fi rebox.
The decorative volcanic stone and glowing
embers are packaged separately in plastic bags
located in the control area of the fi replace.
If the logs are being installed for the fi rst time,
the following paragraphs apply:
DO NOT attempt to install the logs until the ap-
pliance installation has been completed, the gas
line connected and tested for leaks and the initial
burner operation has been checked out.
Proper twig placement is critical to prevent soot-
ing. Twigs should be placed in the gaps between
the fl ame peaks and should be positioned so
that at no time they impinge the fl ames.
Step 1. Remove the appliance front door.
Step 2. Remove the log set from the interior
of the fi replace.
Step 3. Remove the logs from their packaging.
Handle logs carefully to prevent breakage.
Step 4. MPB-4035 & MPB-4540 Models
- Remove the restraining strap from the grate
tines. Ensure the grate is fully inserted into
the holes on the fi rebox rear panel and over
the indents on the fi rebox fl oor.
Log Placement
WARNING
This appliance is not meant to burn
wood. Any attempt to do so could
cause irreparable damage to your
appliance and prove hazardous to
your safety.
WARNING
Logs get very hot and will remain
hot up to one hour after gas supply
is turned off. Handle only when
logs are cool. Turn off all electricity
to the appliance before you install
grate and logs.
WARNING
The size and position on the log set
IS Critical to give your appliance a
safe, reliable and attractive fl ame
pattern. Any attempt to use a dif-
ferent log set in the fi replace will
void the Warranty and will result in
incomplete combustion, sooting,
and poor fl ame quality.
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Glowing Embers, Vermiculite, Decorative Volcanic Stone And Log
Placement Instructions:
Step 1. Separate the Glowing Embers (Rockwool) into pieces about
the size of a quarter (see Figure 13). Keep the pieces fl uffed up, not
matted.
MPB-3328 & MPB-3530 Models -
Distribute these pieces over the burner as shown in Figure 14. Do not use
more than is shown. The glowing embers should not be placed directly
over the large burner slots as shown in Figure 14.
MPB-4035 & MPB-4540 Models -
Place the center log (Log No. 1) on the burner as shown on Page 12.
Distribute the glowing ember pieces at the front of the burner as shown
in Figure 15. Do not use more than is shown. The glowing embers
should not be placed directly over the large burner slots as shown in
Figure 15.
Note: This appliance is provided with enough Glowing Embers for
several applications; do not feel compelled to use all that is in a
new bag. For best glowing effect, replace the ember material annu-
ally. Replacement Glowing Embers are available (Catalogue Number
88L53).
Step 2. Mound up a portion of the vermiculite (light colored material) in
front of the burner and grate. Sprinkle the dark colored decorative volcanic
stone on top of the vermiculite in a pleasing pattern. For best results,
spread in a non-uniform manner while ensuring complete coverage of
the black sheetmetal surface.
See Figure 14 - MPB-3328 or MPB-3530, or Figure 15 - MPB-4035 or
MPB-4540 models.
Note: Do Not place vermiculite or decorative volcanic stone on top of
the gas burner where it will block the burner ports.
Step 3. Position the individual logs as described on Pages 11 (MPB-
3328), 12 (MPB-3530) or 13 (MPB-4035 and MPB-4540).
Figure 14
Figure 13
Figure 15
Note: Your application may not require the use of all of the provided
vermiculite, or decorative volcanic stone. Replacement vermiculite,
volcanic stone and glowing embers is available (see below for ordering
information).
Do Not Place Glowing Embers Over Large Burner Ports
Glowing EmbersVermiculite
(light colored material) Decorative Volcanic stone
(dark colored material)
Do Not Place Glowing Embers Over Large Burner Ports
Glowing EmbersVermiculite
(light colored material) Decorative Volcanic stone
(dark colored material)
MPB-3328 and MPB-3530
REFERENCE
Firebox Accessories / Parts
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers
(1 oz. rockwool)
42363 Vermiculite, Bag (2 liters)
80L42 FDVS Bag of Decorative
Volcanic Stone
Table 4
Glowing Embers
Bag of Glowing
Embers (rockwool)
Separate into Quarter
Size (separate) Pieces
MPB-4035 and MPB-4540
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MPB-3328 LOG PLACEMENT
1
Position the individual logs as shown below. Logs should be placed
in the order shown. Position the rear log on the brackets at the
rear of the fi rebox with the log's notches directly over the brackets.
Position the right log (log no. 3) by inserting the pin from the rear
log into the hole on its upper end. Place the left log and then the
smaller left and right top logs. All logs that have notches to fi t over
the grate tines should be positioned with these notches directly
against the grate. All top logs that rest on lower logs, do so over
attened mounting faces in the bottom logs.
Proper log and twig placement is critical to encourage outstanding
ame appearance and prevent sooting.
3
2
4
56
1
2
3
4
6
5
Figure 16
LOG SET
Catalog Number
24M1501
* Item
Description (stamped #)
1
Log, Rear (39-12)
2
Log, Left (39-1)
3
Log, Right (39-2)
4
Log, Top Center (39-13)
5
Log, Top/Left (39-3)
6
Log, Top/Right (39-4)
* Item numbers above correspond to photos
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MPB-3530 LOG PLACEMENT
1
Position the individual logs as shown below. Logs should be placed
in the order shown. Position the rear log on the brackets at the
rear of the fi rebox with the log's notches directly over the brackets.
Position the right log (log no. 3) by inserting the pin from the rear
log into the hole on its upper end. Place the left log and then the
smaller left and right top logs. All logs that have notches to fi t over
the grate tines should be positioned with these notches directly
against the grate. All top logs that rest on lower logs, do so over
attened mounting faces in the bottom logs.
Proper log and twig placement is critical to encourage outstanding
ame appearance and prevent sooting.
56
2
4
3
1
2
43
6
5
LOG SET
Catalog Number
24M2201
* Item
Description (stamped #)
1
Log, Rear (39-5)
2
Log, Left (39-1)
3
Log, Right (39-2)
4
Log, Top Center (39-6)
5
Log, Top/Left (39-3)
6
Log, Top/Right (39-4)
* Item numbers above correspond to photos
Figure 17
13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MPB-4035 & MPB-4540 LOG PLACEMENT
1
Position the individual logs as shown below. Logs should
be placed in the order shown. Position the center log on the
burner fi rst, then place the glowing embers as shown in Fig-
ure 15. Place the rear log, both the right and left, and then the
smaller left and right top logs. All logs that have notches to fi t
over the grate tines should be positioned with these notches
directly against the grate. All top logs that rest on lower logs,
do so over fl attened mounting faces in the bottom logs.
Proper log and twig placement is critical to encourage out-
standing fl ame appearance and prevent sooting.
23
4
56
1
2
3
4
6
5
LOG SET
Catalog Number
24M2501
* Item
Description (stamped #)
1
Log, Center (39-8)
2
Log, Rear (138)
3
Log, Right (39-10)
4
Log, Left (39-9)
5
Log, Top/Left (39-11)
6
Log, Top/Right (39-11)
* Item numbers above correspond to photos
Figure 18
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WIRING DIAGRAMS
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance
on a pullout panel located within the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN-
GEROUS APPLIANCE OPERATION.
WARRANTY
Your gas appliance is covered by a limited twenty
year warranty. You will fi nd a copy of the war-
ranty accompanying this manual. Please read
the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu-
ments for future reference.
REPLACEMENT PARTS
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
When ordering repair parts, always give the
following information:
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fi replace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 1-800-9-LENNOX or visit our website at www.lennox.com.
Your Fireplace's Model Number ________________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed ___________________________
The Type of Gas Your Fireplace Uses ____________________________________
Your Dealer's Name ________________________________________________
If you encounter any problems or have any ques-
tions concerning the installation or application
of this system, please contact your distributor,
or Lennox directly:
LHP
1110 West Taft Avenue • Orange, CA 92865
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
SIT Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM105°C – 18 GA. wire.
Thermopile
H
TP
TH
T
P
T
*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT
SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;
OR CONNECT WIRES TO OPTIONAL ON/OFF SWITCH OR WALL
SWITCH OR THERMOSTAT OR REMOTE CONTROL RECEIVER
TO OPERATE UNIT.
*OPTIONAL ON/OFF SWITCH,
WALL SWITCH, THERMOSTAT
OR REMOTE CONTROL RECEIVER
AB
HCTIW
S
T
IMI
L
WT
BK
BK
BK
Schematic Representation Only
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
BK
Junction Box
Transf.
120 V.
24 V
Factory Wired Field Wired
BL
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-100 and FBK-200 Kits
R
W
BL
OPT
BLOWER
G
W
*OPTIONAL
ACCESSORY
SWITCH
120
VAC.
BK
W
Gas Valve
B
R
IGNITER
PILOT
ASSEMBLY
Break Off
Tab
BK
G
*Blower speed control switch is provided in FBK200 blower kit.
Outlet Box
Green Ground
Screw
Hot side of Outlet
Schematic Representation Only
**ON/OFF Switch (Integral
with Gas Valve)
**Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
Red
pigtail
Black
pigtail
White Wire
to Opposite
Side
G
LIMIT SWITCH
OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT OR
OPTIONAL REMOTE RECEIVER
BK BK
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
BK
Junction Box
Transf.
120 V.
24 V
Factory Wired Field Wired
BL
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-250 Kits
R
BL
OPT
BLOWER
G
W
120
VAC.
BK
W
Gas Valve
B
R
IGNITER
PILOT
ASSEMBLY
BK
Outlet Box Green
Ground Screw
Hot side of Outlet
Schematic Representation Only
*ON/OFF Switch (Integral
with Gas Valve)
White Wire
To Opposite
Side
Optional FBK-250
Module
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
OPTIONAL ON/OFF SWITCH,
WALL SWITCH, THERMOSTAT
OR REMOTE CONTROL RECEIVER
G
W
LIMIT SWITCH
BK BK
Figure 19
Figure 20 Figure 21
15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Remote Control Kit, Standard
Cat. No. Model No. Description
H0249 RCL Remote Control System
(Standard)
Rocker Switch Kit
Cat. No. Model No. Description
80L41 FRS Rocker Switch Kit
Forced Air Blower Kits
Cat.
No.
Model No. Description
80L84 FBK-100 Blower, Standard
(single speed)
80L85 FBK-200 Blower, Variable Speed
(w/wall-mounted switch)
80L86 FBK-250 Blower, Variable Speed
(w/unit-mounted switch)
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control
the operation of the fi replace burner. Install the
OFF/ON wall switch in a convenient location near
the fi replace.
White Wall Switch Kit
Cat. No. Model No. Description
85L87 FWSK OFF/ON Wall Switch Kit
Unit-Mountable Rocker Switch
This rocker switch kit can be installed directly in
the gas valve mounting bracket (millivolt gas valve
equipped fi replaces) to provide On/Off operation in
lieu of a wall switch.
ACCESSORY COMPONENTS
Standard Remote Control System
The Model RCL (Standard) Remote Control System,
features a simple On/Off control function for the fi re-
place. This model includes a hand-held transmitter,
a remote receiver with wall-mount coverplate and
all hardware required to install the unit. The remote
receiver can be wall or hearth mounted. Forced Air Kit
The FBK-100 blower provides constant velocity forced
air circulation. The FBK-200 assembly with variable
speed, wall-mountable switch provides variable speed
forced air circulation. The FBK-250 assembly with
variable speed wall- or unit-mountable switch, also
provides variable speed forced air circulation.
Touch-Up Paint Kit
Repair of minor scratches and discoloration of
the appliance charcoal painted surfaces may be
accomplished with the touch-up paint kit.
P
A
I
N
T
Touch-Up Paint Kits
(all models)
Cat. No. Model No. Description
H4354 TPK-C Touch-Up Paint (Charcoal)
98K67 Touch-Up Paint (Tan)
Bag of Glowing Embers
Bag of Volcanic Stone
Replacement ember materials or volcanic stone are
available for use with these appliances. Order kits as
part of the periodic maintenance of the appliance.
Decorative Firebox Accessories
(all models)
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers
(1 oz. rockwool)
80L42 FDVS Bag of Decorative
Volcanic Stone
Outside Combustion Air Kits
Cat. No. Model No. Description
81L87 FOAK-4 Combustion Air Kit (with
duct)
81L88 FOAK-4LD Combustion Air Kit
(without duct)
Outside Combustion Air Kits
This kit includes 4" diameter duct, collar and hood for
delivering outside combustion air to the fi replace.
* Assembled 8-Piece Louver Kits
Polished
Brass
Brushed
Stainless
Models
Where
Used
Cat. # Model Cat. # Model
H1522 LK-400B H1523 LK-400BS MPB-3328
H1524 LK-500B H1525 LK-500BS MPB-3530
H1526 LK-600B H1527 LK-600BS MPB-4035
H1528 LK-800B H1529 LK-800BS MPB-4540
Polished Brass & Brushed Stainless Louvers Kits
These kits include a top 4-louver assembly and a
bottom 4-louver assembly. They provide a touch of
elegance. These kits can be retrofi tted to previously
installed appliances.
* Lennox Nameplate Logo, 12L15, is sold separately.
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Arch Door Kit - Polished Brass
Cat. No. Model Models-Where Used
98L05 ADK33CPB MPB-3328
26M43 ADK35CMPB MPB-3530
81L35 ADK40CPB MPB-4035
81L36 ADK45CPB MPB-4540
Arch Door Kit - Brushed Stainless Steel
Cat. No. Model Models-Where Used
98L62 ADK33CBS MPB-3328
26M44 ADK35CMBS MPB-3530
98L69 ADK40CBS MPB-4035
98L70 ADK45CBS MPB-4540
Arch Door Kits
The arch door kits are easy to install and do not re-
quire hardware to attach them to the standard door
frame. The decorative arch kits can not be used in
conjunction with the screen panel kit.
ACCESSORY COMPONENTS
Polished Brass & Brushed Stainless Hood Kits
Attractive hoods are available in two styles. These hoods are designed to be fi tted to the glass viewing sides
of the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation,
the hood reduces heat effects to decorative mantles and fi nish materials located above the fi replace opening.
The hood kit replaces the standard hood that comes with these appliances and snaps into place. These kits
can be retrofi tted to previously installed appliances.
Eyebrow Hood Kits
Polished Brass Brushed Stainless Models
Where Used
Cat. # Model Cat. # Model
98L10 EB33PB 98L11 EB33BS MPB-3328
MPB-3328
96K67 EB35PB 88L49 EB35BS MPB-4035
96K68 EB40PB 88L50 EB40BS MPB-4035
96K69 EB45PB 88L51 EB45BS MPB-4540
* These hood kits replace the standard hood that comes
with these fi replaces.
Polished Brass & Brushed Stainless 2-Piece Door Frame Kits
These kits are designed to attach directly to the front face of the appliance at the glass enclosure panel's top
and bottom edges.
2- Piece Door Frame Kits
Polished Brass Brushed Stainless Models
Where Used
Cat. # Model Cat. # Model
98L18 2DFK33PB 98L19 2DFK33BS MPB-3328
26M88 2DFK35PB 26M91 2DFK35BS MPB-4035
26M89 2DFK40PB 26M92 2DFK40BS MPB-4035
26M90 2DFK45PB 26M93 2DFK45BS MPB-4540
Door Frame Kits
A decorative door frame kit is available for use with these appliances. It is designed to attach directly to the front face
of the appliance at the four edges of the glass enclosure panel resulting in the appearance of a picture frame.
4 Piece Door Trim Kits
Polished Brass Brushed Stainless Models
Where
Used
Cat. # Model Cat. # Model
98L22 4DFK33PB 98L23 4DFK33BS MPB-3328
26M82 4DFK35PB 26M85 4DFK35BS MPB-3530
26M83 4DFK40PB 26M86 4DFK40BS MPB-4035
26M84 4DFK45PB 26M87 4DFK45BS MPB-4540
Brickaded Wall Liner Kits
Cat. No. Model No. Description
H4683 MBLK-33B Brick Liner Kit, MPB-3328
H4684 MBLK-35B Brick Liner Kit, MPB-3530
H4685 MBLK-40B Brick Liner Kit, MPB-4035
H4686 MBLK-45B Brick Liner Kit, MPB-4540
Brickaded Panel Liner Kit
The brickaded liner kits include ceramic panels as
shown here. The panels have brick-like features in relief.
2-PIECE LOUVER SET KITS
Polished Brass Brushed Stainless Models
Where Used
Cat. # Model Cat. # Model
98L09 2LVR33PB 98L08 2LVR33BS MPB-3328
96L05 2LVR35PB 96L09 2LVR35BS MPB-3530
96L06 2LVR40PB 96L10 2LVR40BS MPB-4035
96L07 2LVR45PB 96L11 2LVR45BS MPB-4540
2-Piece Polished Brass and Brushed Stainless Louvers Kits
These louvers are designed to replace either the middle charcoal louver of each set or the charcoal louver in
each set closest to the glass door. These kits include two narrow louvers. They provide a touch of elegance
to these appliances. These kits can be retrofi tted to previously installed appliances.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 17
ARCH DESIGN SCREEN DOOR KITS
Cat. No. Model Description Where Used
H0858 AD35C 35” Arch Doors, Charcoal
MPB3530
H0859 AD35TI 35” Arch Doors, Textured Iron
H0860 AD35SP 35” Arch Doors, Satin Pewter
H0861 AD35AB 35” Arch Doors, Antique Brass
H0862 AD40C 40” Arch Doors, Charcoal
MPB4035
H0863 AD40TI 40” Arch Doors, Textured Iron
H0864 AD40SP 40” Arch Doors, Satin Pewter
H0865 AD40AB 40” Arch Doors, Antique Brass
H0866 AD45C 45” Arch Doors, Charcoal
MPB4540
H0867 AD45TI 45” Arch Doors, Textured Iron
H0868 AD45SP 45” Arch Doors, Satin Pewter
H0869 AD45AB 45” Arch Doors, Antique Brass
ARCH PANE DESIGN KITS
H0930 APD35C 35” Arch Pane Doors, Charcoal
MPB3530
H0931 APD35TI 35” Arch Pane Doors, Textured Iron
H0932 APD35SP 35” Arch Pane Doors, Satin Pewter
H0933 APD35AB 35” Arch Pane Doors, Antique Brass
H0934 APD40C 40” Arch Pane Doors, Charcoal
MPB4035
H0935 APD40TI 40” Arch Pane Doors, Textured Iron
H0936 APD40SP 40” Arch Pane Doors, Satin Pewter
H0937 APD40AB 40” Arch Pane Doors, Antique Brass
H0938 APD45C 45” Arch Pane Doors, Charcoal
MPB4540
H0939 APD45TI 45” Arch Pane Doors, Textured Iron
H0940 APD45SP 45” Arch Pane Doors, Satin Pewter
H0941 APD45AB 45” Arch Pane Doors, Antique Brass
H0950 SD40C 40” Sq. Doors, Charcoal
MPB-4035
H0951 SD40TI 40” Sq. Doors, Textured Iron
H0952 SD40SP 40” Sq. Doors, Satin Pewter
H0953 SD40AB 40” Sq. Doors, Antique Brass
H0954 SD45C 45” Sq. Doors, Charcoal
MPB4540
H0955 SD45TI 45” Sq. Doors, Textured Iron
H0956 SD45SP 45” Sq. Doors, Satin Pewter
H0957 SD45AB 45” Sq. Doors, Antique Brass
SQUARE PANE DESIGN KITS
H0962 SPD35C 35” Sq. Pane Doors, Charcoal
MPB3530
H0963 SPD35TI 35” Sq. Pane Doors, Textured Iron
H0964 SPD35SP 35” Sq. Pane Doors, Satin Pewter
H0965 SPD35AB 35” Sq. Pane Doors, Antique Brass
H0966 SPD40C 40” Sq. Pane Doors, Charcoal
MPB-4035
H0967 SPD40TI 40” Sq. Pane Doors, Textured Iron
H0968 SPD40SP 40” Sq. Pane Doors, Satin Pewter
H0969 SPD40AB 40” Sq. Pane Doors, Antique Brass
H0970 SPD45C 45” Sq. Pane Doors, Charcoal
MPB4540
H0971 SPD45TI 45” Sq. Pane Doors, Textured Iron
H0972 SPD45SP 45” Sq. Pane Doors, Satin Pewter
H0973 SPD45AB 45” Sq. Pane Doors, Antique Brass
SQUARE DESIGN SCREEN DOOR KITS
Cat. No. Model Description Where Used
H0946 SD35C 35” Sq. Doors, Charcoal
MPB3530
H0947 SD35TI 35” Sq. Doors, Textured Iron
H0948 SD35SP 35” Sq. Doors, Satin Pewter
H0949 SD35AB 35” Sq. Doors, Antique Brass
Arch Design Arch Pane Design Square Pane Design
Square Design
ACCESSORY COMPONENTS
3 Piece Trim Kit
Cat. No. Model No. Description
H0453 TK33PB3 33” Polished Brass,
MPB-3328
96K21 TK35PB3 35” Polished Brass,
MPB-3530
96K22 TK40PB3 40", Polished Brass,
MPB-4035
96K23 TK45PB3 45", Polished Brass,
MPB-4035
H1813 TK33BS3 33” Brushed Stainless,
MPB-3328
H1815 TK35BS3 35” Brushed Stainless,
MPB-3530
H1816 TK40BS3 40", Brushed Stainless,
MPB-4035
H1817 TK45BS3 45", Brushed Stainless,
MPB-4540
4 Piece Trim Kit
Cat. No. Model No. Description
96K17 TK35PB4 35” 4 Piece Finish Trim Kit,
Polished Brass, MPB-3530
96K18 TK40PB4 40” 4 Piece Finish Trim Kit,
Polished Brass, MPB-4035
96K19 TK45PB4 45” 4 Piece Finish Trim Kit,
Polished Brass, MPB-4540
3 and 4-Piece Trim Kits
This kit contains brass trim pieces used to fi nish
the gaps between the wall board and the fi replace,
providing the appliance a brass perimeter highlight.
This kit contains the trim pieces and instructions.
4-Piece
Trim Kit 3-Piece
Trim Kit
Screen Panel Kit
This easy to install optional Screen Panel installs over
the standard glass enclosure panel to prevent inadvertant
direct contact with the hot glass surface. These Screen
Panels cannot be used in conjunction with the arch door
kits or door frame kits.
Screen Panel Kits
Cat. No. Model No. Models Where Used
98L04 HG33 MPB-3328
26M48 HG35M MPB-3530
26M49 HG40M MPB-4035
26M50 HG45M MPB-4540
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Decorative Arch Screen Panel Kit
Cat. No. Model Model
H3593 DASPK35TI 35” Dec. Arch Screen Panel
Decorative Arch Screen Panel Kit
This easy to install optional screen installs over the
standard glass enclosure panel to provide protection
from inadvertant direct contact with the hot glass
surface. These screen panels cannot be used in con-
junction with the arch door kits or door frame kits.
H3541 CUGK35C 35” Charcoal
UPPER GRILLE KITS
CRESCENTS
H3542 CUGK35TI 35” Textured Iron
H3543 CUGK35SP 35” Satin Pewter
H3544 CUGK35AB 35” Ant. Brass
H3569 SLGK35C 35” Charcoal
LOWER GRILLE KITS
SUNRISE
H3570 SLGK35TI 35” Textured Iron
H3571 SLGK35SP 35” Satin Pewter
H3572 SLGK35AB 35” Antique Brass
Cat. No.#Model Description Model Series
H3565 SUGK35C 35” Charcoal
UPPER GRILLE KITS
SUNRISE
H3566 SUGK35TI 35” Textured Iron
H3567 SUGK35SP 35” Satin Pewter
H3568 SUGK35AB 35” Antique Brass
H3545 CLGK35C 35” Charcoal
LOWER GRILLE KITS
CRESCENTS
H3546 CLGK35TI 35” Textured Iron
H3547 CLGK35SP 35” Satin Pewter
H3548 CLGK35AB 35” Antique Brass
Sunrise Style (upper grille shown)
Crescent Style (lower grille shown)
19
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVE
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot which must be lighted with a piezo
igniter. When lighting the pilot, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the fl oor because some gas is
heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open fl ame.
• Open windows.
Do not light any appliance.
Do not touch any electrical switches.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the lower control compartment.
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close lower control compartment.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this Page.
2. Access the lower control compartment.
3. Turn remote wall switch to “OFF.”
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone.
If your gas supplier cannot be reached, call the fi re depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualifi ed service technician. Force
or attempted repair may result in a fi re or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Note: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.
SIT
MILLIVOLT
GAS VALVE
SIT
MILLIVOLT PILOT
O
N
O
F
F
P
I
L
O
T
L
O
H
I
H
I
L
O
W
H
TP
T
HT
P
T
P
I
L
O
T
P
I
L
O
T
O
N
ti
O
F
F
OUT
IN
IGNITER
6. Wait fi ve (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this Page. If you
do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
8. Push in control knob all the way and hold in.
Immediately light the pilot by triggering the
spark igniter (pushing the button) until pilot
lights. Continue to hold the control knob in
for about 1 minutes after the pilot is lit.
Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat
steps 5 through 8.
If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.
If pilot will not stay lit after several
tries, turn the control knob to “OFF”
and call your service technician or gas
supplier.
9. Turn gas control knob counterclockwise
to “ON.”
10. Close lower control compartment.
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT
INSTRUCTIONS D'ALLUMAGE
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à
étincelle (en poussant le bouton) jusqu’à ce que la veilleuse
s’enflamme. Continuez de tenir le bouton de réglage enfoncé
pendant environ 90 secondes après l’allumage de la veilleuse.
Relâchez le bouton et il sortira
subitement. La veilleuse devrait rester
allumée. Si elle s’éteint, répétez les
étapes 5 à 8 inclusivement.
Si le bouton ne sort pas
automatiquement après avoir été
relâché, arrêtez immédiatement et
téléphonez à votre technicien de
service ou à votre fournisseur de gaz.
Si la veilleuse refuse de rester allumée
après plusieurs tentatives, tournez le
bouton de réglage jusqu’à sa position
d’arrêt “OFF” et téléphonez à votre
technicien de service ou à votre
fournisseur de gaz.
9. Tournez le bouton de réglage du gaz en
sens inverse des aiguilles d’une
montre jusqu’à sa position
de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Au besoin, rebrancher l’appareil au courant électrique et remettre
l’interrupteur du brûleur principal à la position “ON” ou régler le
thermostat à la température désirée.
12. Si l’appareil ne fonctionne pas, suivre les instructions intitulées
“Pour fermer le gaz qui alimente l’appareil” et appeler un
technicien ou le fournisseur de gaz.
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre
exactement ces instructions.
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune
odeur de gaz autour de l’apareil ainsi que près du sol; certains gaz, étant
plus lourds que l’air, descendent au niveau du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR
DE GAZ:
Éteignez toute flamme visible.
Ouvrez les fenêtres.
N’allumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez d’aucun téléphone dans votre édifice.
Appelez immédiatement votre compagnie de gaz en utilisant le téléphone
du voisin.
S’il vous est impossible de contacter votre compagnie de gaz, appelez
le service des incendies.
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,
n’essayez pas de le réparer. Communiquez immédiatement avec un
technicien de service qualifié. Toute tentative pour le forcer ou le
réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien compétent
pour faire inspecter l’appareil et remplacer toute pièce du système de
réglage ou commande du gaz qui a été sous l’eau.
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4. Assurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”.
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes
de sécurité au verso de cette plaque. Si vous ne remarquez aucune
odeur de gaz, passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
sens inverse des aiguilles d’une montre jusqu’à la position de
veilleuse “PILOT”.
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
restera allumée jusqu’au retour du service normal.
2. Pour une fermeture complète, tournez l’interrupteur mural à la
position d’arrêt “OFF”.
3. Ouvrez le compartiment de contrôle du bas.
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”. Ne forcez pas le bouton.
5. Fermez le compartiment de contrôle du bas.
VANNE GAZ
MILLIVOLT SIT
SIT
MILLIVOLT PILOT
H
I
L
O
W
H
TP
TH
T
P
T
P
I
L
O
T
P
I
L
O
T
O
N
t
i
O
F
F
OUT
IN
PIEZO-ELECTRIQUE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Lennox Hearth Products LENNOX MPB3328CNE Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur
Ce manuel convient également à