Hormann Speed-Guardian™ 5000 42 Guide d'installation

Catégorie
Porte de garage
Taper
Guide d'installation
EN Instructions for Fitting, Operating and Maintenance
High-Speed Door SG5000U42
2091709 / SG 5000U42 RE / Stand: 11.2023 / Druck: 11.2023
Scan QR Code
for Supplemental
Video Instructions
22091709 / SG 5000U42 RE / 11.2023
T20; T30; T40
#2
7; 8; 13; 15; 17; 19
2.5; 3; 4;
5;
6
7; 8; 10; 13; 17
2091709 / SG 5000U42 RE / 11.2023 3
=
=
DW > 3500 (137-13/16)
DW > 5000 (196-7/8)
Optional Accessory:
thermal break for wall
Optional accessory:
Supplied only if hood is
ordered
ENGLISH / FRANÇAIS / ESPAÑOL
Important Installation Instructions
WARNING
To reduce the risk of severe injury or death
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS
2. Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury.
Have qualified service personnel make repairs to cables, spring, assemblies, and other hardware before installing the
operator.
3. Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to
the power unit) connected to the door before installing the operator.
4. A commercial/industrial door operator that has exposed moving parts capable of causing injury to persons or employs a
motor deemed indirectly accessible by UL325 10.6 by virtue of its location above the floor shall include:
Install the door operator at least 2.44m (8ft) or more above the floor;
or
if the operator must be installed less than 2.44m (8ft) above the floor, then exposed moving moving parts must be
protected by covers or guarding, provided by the manufacturer;
or
both (a) and (b)
5. Do not connect the door operator to the source of power until instructed to do so.
6. Locate the control station: (a) within sight of the door, and (b) at a minimum height of 1.53m (5ft) above floors, landings,
steps, or any other adjacent walking surface and (c) away from all moving parts of the door.
7. Ensure that the track attached Entrapment Warning Label is visible.
8. For products having a manual release, instruct the end user on the operator of the manual release.
Instructions de montage importantes
AVERTISSEMENT
Pour réduire le risque de blessures graves ou de décès
1. LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS DE MONTAGE
2. N’installez que sur une porte en bon état de fonctionnement et équilibrée. Une porte qui ne fonctionne pas correctement
risque de causer des blessures graves. Avant d’installer la motorisation, demandez au personnel qualifié de réparer les
câbles, ressorts, assemblages et tout autre outil.
3. Avant d’installer la motorisation, enlevez toutes les cordes de traction et retirez, ou rendez inopérants, tous les
mécanismes de verrouillage (sauf s’ils sont verrouillés mécaniquement et/ou électriquement à la source d’énergie) reliés à
la porte.
4. Une motorisation de porte commerciale/industrielle à pièces mobiles exposées susceptibles de causer des blessures aux
personnes ou utilisant un moteur considéré indirectement accessible par la norme UL325 10.6 en raison de son
emplacement au-dessus du sol, doit inclure :
une installation à au moins 2,44 m (8 pieds) ou plus au-dessus du sol;
ou
des caches ou un capot fournis par le fabricant pour les pièces mobiles exposées, si la motorisation doit être installée
à moins de 2,44 m (8 pieds) au-dessus du sol;
ou
à la fois (a) et (b)
5. Ne connectez pas la motorisation de porte à la source d’alimentation avant d’avoir reçu l’instruction de le faire.
6. Localisez le poste de commande : (a) à portée de vue depuis la porte, et (b) à une hauteur minimum de 1,53 m (5 pieds)
au-dessus des étages, paliers, marches ou toute autre surface de marche adjacente et (c) loin de toute les parties mobiles
de la porte.
7. Assurez-vous que l’étiquette d’avertissement de piégeage attachée à la voie est visible.
8. Pour les produits à déverrouillage manuel, indiquez à l’utilisateur final le nom de la motorisation pour le déverrouillage
manuel.
42091709 / SG 5000U42 RE / 11.2023
ENGLISH / FRANÇAIS / ESPAÑOL
Instrucciones importantes de instalación
ADVERTENCIA
Para reducir el riesgo de lesiones grave y muerte
1. LEA Y SIGA TODAS LAS INSTRUCCIONES DE INSTALACIÓN
2. Instale solo en una puerta que funcione correctamente y esté balanceada. Una puerta que funciona incorrectamente
podría causar lesiones graves. Haga que personal de servicio calificado repare los cables, resortes, ensambles y
cualquier otro accesorio antes de instalar el operador.
3. Retire todas las cuerdas de tracción y quite, o mantenga inoperantes, todas las cerraduras conectadas a la puerta antes
de instalar el operador (a menos que estén trabadas mecánica y/o eléctricamente a la unidad de potencia).
4. Si un operador de puerta comercial / industrial tiene expuestas partes móviles capaces de causar lesiones a personas o
emplea un motor al que la norma UL325 10.6 considere indirectamente accesible como resultado de su ubicación sobre
el piso, se deberá realizar lo siguiente:
Instale el operador de la puerta al menos a 2.44 m (8 pies) o más sobre el piso;
o
si el operador debe instalarse a menos de 2.44 m (8 pies) sobre el piso, las partes móviles expuestas deben
protegerse con cubiertas o protecciones, suministradas por el fabricante;
o
tanto (a) como (b).
5. No conecte el operador de la puerta a la fuente de energía hasta que se le indique.
6. Ubique la estación de control: (a) a la vista de la puerta, y (b) a una altura mínima de 1.53 m (5 pies) sobre los pisos,
descansos, escalones o cualquier otra superficie adyacente para caminar y (c) lejos de todas las partes móviles de la
puerta.
7. Asegúrese de que la etiqueta de advertencia de atrapamiento adjunta a la vía esté visible.
8. Para los productos que tienen una liberación manual, indique al usuario final sobre el operador de liberación manual.
2091709 / SG 5000U42 RE / 11.2023 5
Dissemination as well as duplication of this document and the use and
communication of its content are prohibited unless explicitly permitted.
Noncompliance will result in damage compensation obligations. All rights
reserved in the event of patent, utility model or design model registration.
Contents Dear Customer,
We are delighted that you have decided to choose a high-
quality product from our company.
1 About These Instructions
These instructions are divided into a text section and an illus-
trated section. The illustrated section can be found after the
text section.
These instructions are original instructions as outlined in
the EC Directive2006 / 42 / EC. Read through all of the inst-
ructions carefully: they contain important information about
the product. Pay attention to and follow the instructions pro-
vided, particularly the safety instructions and warnings.
Please keep these instructions in a safe place and make sure
that they are available to all users at all times.
The manufacturer is not liable for any damage caused as a
result of non-compliance with the operating instructions and
the information contained therein or due to non-customary
use of the industrial door.
Competent operation and proper maintenance influence the
performance and availability of your industrial door to a con-
siderable degree. Operating errors and inadequate mainte-
nance lead to avoidable failures. Only competent operation
and proper maintenance will guarantee satisfactory, long-
term operational safety.
Our customer service department will be happy to assist you.
Please contact them if you have any questions after working
through these operating instructions.
1.1 Further applicable documents
Depending on the ordered accessories, the delivery includes
further instructions, e.g. instructions on how to control the
door. Also read these instructions carefully and thoroughly.
Pay attention to and follow the instructions provided herein,
particularly the safety instructions and warnings.
1.2 Warnings used
The general warning symbol indicates a danger that
can lead to injury or death. In the text, the general warning
symbol will be used in connection with the caution levels
described below. In the illustrated section, an additional
instruction refers back to the explanation in the text.
DANGER
Indicates a danger that leads directly to death or serious
injuries.
WARNING
Indicates a danger that can lead to death or serious injuries.
CAUTION
Indicates a danger that can lead to minor or moderate
injuries.
ATTENTION
Indicates a danger that can lead to damage or destruction
of the product.
1 About These Instructions .....................................6
1.1 Further applicable documents ................................6
1.2 Warnings used ........................................................6
1.3 Symbols used ......................................................... 7
1.4 Abbreviations used ................................................. 7
2 Safety Instructions ........................................ 7
2.1 Intended use ...........................................................7
2.2 Qualification of personnel .......................................8
2.3 Standards and regulations .....................................8
2.4 General safety instructions ..................................... 8
2.5 Safety instructions for operation ............................8
2.6 Safety instructions for maintenance and
troubleshooting .......................................................8
3 Fitting ..................................................................... 9
4 Putting into Service .............................................. 9
4.1 Setting the end-of-travel positions ......................... 9
4.2 Test run ................................................................. 10
5 Operation .............................................................10
5.1 Instructed personnel .............................................10
5.2 Normal wear .........................................................10
5.3 Emergency-OFF ...................................................10
6 Inspection and Maintenance .............................10
6.1 Maintenance intervals ...........................................11
6.2 Wearing parts .......................................................11
7 Control .................................................................11
8 Malfunctions and Troubleshooting ...................12
9 Cleaning and Care ..............................................12
10 Extension and Conversion ................................. 12
11 Dismantling and Disposal ..................................12
...................................................................13
62091709 / SG 5000U42 RE / 11.2023
ENGLISH
1.3 Symbols used
Important advice to prevent injury to persons or
damage to property
Warning of dangerous electrical voltage
Tighten the screws firmly
Tighten the screws by hand
Optional or door size dependent components
Drilling in steel
Drilling in concrete
Use suitable lifting devices (e.g.forklift,crane)
Remove residue
Inspect
Danger of crushing
Risk of shearing
Risk of impact
Risk of trapping during door travel
Grease
Thread lock
Correct arrangement or activity
Non-permissible arrangement or activity
Remove and dispose of component or
packaging
See text section
See illustrated section
See separate Fitting Instructions for the control
or for the additional electrical control elements
1.4 Abbreviations used
EN European Standard
FFL Top edge of finished floor line
DW Door opening width
DH Door opening height
Units mm and (inches)
NM and (Ft-Lbs)
mm ² and (FT ²)
2 Safety Instructions
When used properly and for the intended purpose, industrial
doors are reliable and safe to operate. Nevertheless, when
used incorrectly or for purposes other than those intended,
they can pose a risk. We therefore expressly draw your atten-
tion to the safety instructions contained in the individual
chapters.
2.1 Intended use
Industrial doors are used to close passage openings, to
safely shut off rooms, to make machines safe and secure, to
save energy costs, to improve the room air conditions and to
accelerate the flow of materials.
2091709 / SG 5000U42 RE / 11.2023 7
ENGLISH
Intended use also includes paying attention to these instruc-
tions and observing inspection and maintenance conditions.
Any other or further use is regarded as non-intended use.
The manufacturer / supplier is not liable for any damage
resulting from this. The risk is borne solely by the user.
2.2 Qualification of personnel
Only qualified and instructed personnel may fit, operate and
maintain the industrial door.
Before commencing work the assigned personnel must read
these instructions, particularly chapter2.
For safety reasons, specify distinct responsibilities for opera-
tion, maintenance and repairs to ensure that there are no
unclear assignments.
2.3 Standards and regulations
At the least, observe the following European standards and
directives, as well as country-specific safety requirements,
standards and regulations.
Standards
ANSI/DASMA
108-2017
Standard Method for Testing Sectional
Garage Doors, Rolling Doors and Flexible
Doors: Determination of Structural Perfor-
mance Under Uniform Static Air Pressure
Difference
UL325 Standard for safety: Door, drape, gate,
louver, and window operators and systems
Electrical regulations
NFPA70 Electrical installations with electronic equip-
ment
**Note that local regulations must be consi-
dered but are not listed**
Accident prevention regulations
NFPA70 Electrical installations and equipment
OSHA1910 Technical Rules for Workplaces
2.4 General safety instructions
• In addition, also observe the generally applicable
statutory regulations and other binding regulations for
accident prevention and environmental protection,
country-specific regulations, and the recognized
specialist technical rules for safe and competent
working. Before beginning work, instruct personnel in
accordance with these rules and regulations.
• Always keep these instructions ready to hand at the
location where the industrial door is used.
• Without the supplier‘s prior approval, do not carry out
any modification, attachment or conversion work on the
industrial door which might compromise safety.
• Do not make any modifications to the software on
programmable control systems.
• The location and operation of fire extinguishers must be
indicated by appropriate information signs. Observe the
statutory fire alarm and fire-fighting regulations.
• All work on the industrial door (such as maintenance,
cleaning work and inspections) may only be performed
during an operational shutdown.
• Only qualified electricians may perform work on the
mains supply.
• Before undertaking any work, disconnect the system
from the mains supply and ensure that it cannot be
inadvertently turned on. If available, deactivate the
emergency opening lever.
2.5 Safety instructions for operation
• Before actuating the door, make sure that no persons or
objects are located in the door‘s area of travel.
• Do not reach into the guide or guide area while the door
is in operation.
• Only actuate the industrial door if it is safe and
functional. All protective devices and safety-related
devices (e.g. detachable protective devices and
emergency-OFF devices) must be present and
functioning.
• Do not modify or put the safety devices out of operation.
2.6 Safety instructions for maintenance and
troubleshooting
• Perform inspection and maintenance work as described
in chapter6. Comply with the maintenance intervals and
note the information on the replacement of parts / partial
equipment.
• Maintenance and troubleshooting may only be carried
out by specialist personnel.
• Only use spare parts that comply with the technical
requirements specified by the manufacturer. This is
always guaranteed when original spare parts are used.
• Only carry out welding, burning and grinding work on the
industrial door if this work has been expressly approved.
Forexample, there may be a risk of fire and explosion!
Prior to welding, burning and grinding, remove dust and
combustible materials from the industrial door and its
surroundings and ensure that there is adequate
ventilation (risk of explosion)!
• Before disassembling the operator, fix the shaft on the
operator side (e.g. with a forklift).
82091709 / SG 5000U42 RE / 11.2023
ENGLISH
3 Fitting
DANGER
Mains voltage!
Contact with the mains voltage presents the danger of a
deadly electric shock. For that reason, observe the fol-
lowing warnings under all circumstances:
Only qualified electricians may perform work on the
mains supply.
Make sure that the on-site electrical installation
complies with the applicable safety requirements.
Ensure that the national regulations governing the
operation of electrical equipment are complied with.
Install the control unit for the industrial door operator
within sight of the door.
Before undertaking any electrical work, disconnect the
system from the mains supply and ensure that it
cannot be inadvertently turned on.
ATTENTION
External voltage
External voltage on the connecting terminals of the control
will destroy the electronics.
Do not apply any external voltage (e.g. mains voltage)
to the connecting terminals of the control unit.
ATTENTION
Pull forces on electric cables
Pull forces on electric cables will destroy the electronics.
Never pull on the connecting leads of the electrical
components.
NOTE:
The included fixing material is approved for the following
subsurfaces.
Concrete screws: Fitting subsurface cracked concrete
C20 / 25, uncracked concrete C20 / 25
and brickwork.
Long shaft plug: Fitting subsurface concrete C12 / 15,
gas concrete, sand-lime solid brick
and solid brick.
Metric screws: Fitting subsurface steel, a suitable
material thickness and strength must
be observed.
For deviating subsurfaces, suitable fixing material must
beselected (not in scope of delivery).
NOTE:
Also follow the other enclosed instructions for installation of
electrical connections and fitting additional electrical control
elements.
To fit the door:
1. Take precautionary measures to make the site safe.
2. Check the on-site fitting conditions for the door (check
measurements).
3. Check the quality of the structure for its strength.
4. Choose suitable fastenings.
5. Unpack the door and check for damage.
6. If delivered by a freight forwarder: Report any damage
immediately.
7. Check that the delivery is complete.
8. Dispose of the packaging material.
9. Fit the door as shown in the illustrated section.
4 Putting into Service
WARNING
Faulty door
A faulty door may injure persons or damage objects.
Only put the door into service if it is in perfect
condition.
WARNING
Door movements
Door travel may injure persons or damage
objects.
Make sure that no persons or objects are
in the door's closing area during operation.
Never use the door to lift objects or
persons.
Never reach into the guide, guide area,
chain, toothed wheel or return pulley
during door operation.
4.1 Setting the end-of-travel positions
The end-of-travel positions of the door are set on the control
cabinet.
NOTE:
Please follow the instructions supplied with the operator and
control unit.
4.1.1 CLOSE end-of-travel position
ATTENTION
Exceeding the CLOSE end-of-travel position
If the door travels beyond the Close end-of-travel position,
the bottom profile may be compressed. This could disrupt
the diode deactivation of the light grille.
Never exceed the CLOSE end-of-travel position.
2091709 / SG 5000U42 RE / 11.2023 9
ENGLISH
Set the CLOSE end-of-travel position so that the bottom
profile makes full contact with the floor. If the guide is
supported or the floor uneven, select the bottom edge of
the side element as the end-of-travel position.
4.1.2 OPEN end-of-travel position
ATTENTION
Exceeding the OPEN end-of-travel position
If the door travels beyond the OPEN end-of-travel position,
there is a risk of the door curtain slipping out of the side
guides and sustaining damage.
Never exceed the OPEN end-of-travel position.
Set the OPEN end-of-travel position so that the lower
edge of the bottom profile corresponds to the dimension
for the door height.
4.2 Test run
1. After fitting the door, test the functional safety according
to the acceptance / handing-over report.
2. Verify in the test log book (dated and signed) that a test
run has been successfully completed.
3. Hand the entire door documentation over to the owner or
operator of the door.
5 Operation
WARNING
Door movements
Door travel may injure persons or damage
objects.
Make sure that no persons or objects are
in the door's closing area during operation.
Make sure that the door has opened
completely before driving in or out! Never
drive or walk through doorways unless the
door has reached the OPEN end-of-travel
position.
Whenever driving in or out of the opening,
always check that the door curtain has
traveled up far enough to provide the
necessary passage height.
Never use the door to lift objects or
persons.
Do not reach into the guide or guide area
while the door is in operation.
ATTENTION
Emergency operation devices
Too frequent use of the emergency operation devices may
damage them. This will also void the warranty for the door.
Only use the emergency operation devices in the case
of a power failure or during repair work.
ATTENTION
Aggressive media, wind and heat
Aggressive media, wind and heat may damage the door.
Protect the door from aggressive media:
Saltpeter from stone or concrete
Cement
Plaster
Acids
Alkali
Road salt
Aggressive paints or sealants
Aggressive sealants
Do not open or close the door if it is windy (no outside
door).
Avoid temperatures greater than 50°C near the door.
5.1 Instructed personnel
The door may only be operated by persons who have been
instructed in its proper use. A person is considered to be ins-
tructed (EN12453), if they have received instruction as to
how to operate the door safely and has received permission
from the owner to use the door system.
5.2 Normal wear
The design of the door represents state-of-the-art techno-
logy. Pressure marks and abrasive wear are design-related
and cannot be avoided.
5.3 Emergency-OFF
In emergency situations, deenergize the control by
actuating the main switch, pulling the mains plug or, if
available, actuating the red emergency-OFF button.
6 Inspection and Maintenance
WARNING
Unmaintained doors
There is a danger of injury and damage if the door is not
regularly maintained. This will also void the warranty.
Inspect and maintain the door regularly as described in
these instructions or entrust this work to the
manufacturer's service department.
DANGER
Mains voltage!
Contact with the mains voltage presents the danger of a
deadly electric shock.
Before undertaking any electrical work, disconnect the
system from the mains supply and ensure that it
cannot be inadvertently turned on.
10 2091709 / SG 5000U42 RE / 11.2023
ENGLISH
WARNING
Door movements
There is a danger of injury and damage if the
door is actuated during inspection or mainte-
nance work.
Before undertaking any work, disconnect
the system from the mains supply and
ensure that it cannot be inadvertently
turned on.
If available, deactivate the emergency
opening lever / handle.
WARNING
Falling parts
During dismantling, parts may fall and injure
persons or damage property.
Cladding (option)
Fix the cladding (e.g. with a forklift) before
dismantling.
Shaft
Fix the shaft (e.g. with a forklift) before
dismantling the operator.
Only inspect and maintain the door yourself if you are a
qualified specialist (competent person according to
EN12635). In other words, you have the suitable training,
specialist knowledge and practical experience to allow you
to carry out inspection and maintenance correctly and safely.
Observe all the applicable regulations governing work safety.
In general, we recommend entrusting maintenance / inspec-
tion to the manufacturer‘s service department.
The high-speed door is low-maintenance. In normal opera-
ting conditions, all the bearings, including the gears, are lub-
ricated for life and are maintenance-free.
6.1 Maintenance intervals
In compliance with the guidelines for power-operated win-
dows, doors and gates, testing and maintenance of the door
must be carried out once a year, and as far as possible at the
same intervals.
Depending on the size of the door and the annual number of
door cycles, we recommend the following maintenance inter-
vals:
In the case of a high number of door cycles
(>50000peryear):
Servicing of the functional elements every six months:
• Electric operator and brake
• All screw connections
• Travel limit cut-off / creep speed switch-over
• Control / impulse generator
In the case of a smaller number of door cycles:
Annual servicing in conjunction with the stipulated test pro-
cedures.
Check the function of the “D” devices (photocell / light
grille) every six months.
ATTENTION
Maintenance will be
necessary, service
counter expires soon
Malfunction, maintenance
required
NOTE:
It is mandatory to replace the elements
marked with (✱) within the next 5,000 door
cycles.
6.2 Wearing parts
If provided, the indicated maximum assumable cycles
ordoor cycles apply to the following wearing parts:
Wearing parts Cycles Period
Operator (60% ON time) 500,000 2 years
Operator (tubular drive;
60%ON time) 1) 700,000 2 years
Brake 250,000 2 years
Radio crash switch battery – / – 2 years
Energy chain with cable 250,000 2 years
Springs 100,000 2 years
Fabric belts 100,000 2 years
Flat belts (counter
weight,sections) 500,000 2 years
Rollers / slider 100,000 2 years
UPS battery – / – 1.5 years
UPS battery (RW doors) – / – 1 years
Hinges 100,000 2 years
Seals / sealing strip 150,000 2 years
Light grille / photocell – / – 2 years
1) It is compulsory that components are replaced at the above-
mentioned cycles.
7 Control
The control system is manufactured individually for each
door ordered. The respectively applicable wiring diagram is
included in the operator instructions.
Add the wiring diagram and software description to
these instructions.
Each control cabinet has its own identification number.
Always quote this number in the case of queries.
2091709 / SG 5000U42 RE / 11.2023 11
ENGLISH
8 Malfunctions and Troubleshooting
In the case of malfunctions, contact the Customer Service.
Operator power
The operating voltage must be 230V±5%or 460V ±5%. If
the voltage deviates greatly from this, there may be problems
with the operator power. Verify with factory.
9 Cleaning and Care
Use warm water together with a neutral, non-abrasive
cleaning agent (household detergent, pH value7, Isopro-
panol 99.9%).
To clean the surface, use only a soft cloth or window leather.
Rinse off any dirt and dust particles with clear water.
10 Extension and Conversion
WARNING
Unsuitable components
Unsuitable components could overload the door construc-
tion. This could lead to serious injury.
Only use components approved by the manufacturer.
Only extend or convert this door system with the
manufacturer‘s permission.
Carrying out any structural alterations to the product without
the manufacturer‘s permission renders the warranty and
product liability null and void.
11 Dismantling and Disposal
WARNING
Falling parts
During dismantling, parts may fall and injure
persons or damage property
Cladding (option)
Fix the cladding (e.g. with a forklift) before
dismantling.
Shaft
Fix the shaft (e.g. with a forklift) before
dismantling the operator.
Only dismantle this door if you are qualified to do so. In other
words, you have the suitable training, specialist knowledge
and practical experience to allow you to dismantle the door
correctly and safely.
Observe all the applicable regulations governing work safety
when dismantling the door.
To dismantle and dispose of the door:
1. Open the door fully.
2. Carefully roll up the door manually (emergency manual
operation).
3. Tape round the door curtain several times with strong
adhesive tape (e.g.packing tape) to prevent it from
unrolling.
4. Drive a forklift truck with suitable pallet or supporting
frame underneath the shaft, so that the shaft rests on the
pallet or supporting frame.
5. Release the fastenings securing the bearing and the
operator.
6. Lift the shaft or top part together with the operator off
the support brackets.
CAUTION
The operator may slide off the barrel journal
When letting the shaft or top part down, take care to
keep it level.
7. Dismantle the side guides or side elements and support
brackets.
8. Disassemble the door into component parts and dispose
of them properly.
12 2091709 / SG 5000U42 RE / 11.2023
ENGLISH
2091709 / SG 5000U42 RE / 11.2023 13
1.2
1.1
1.1
1.2
1
T30 #2
Unpacking side tracks
Attention: Leave fasteners in place until
the tracks are installed against the wall.
See step 2.1
Attention: Do not discard
metal bracket!
14 2091709 / SG 5000U42 RE / 11.2023
2.4
CheckDim
2.1
2.2
2.3
2.4
2.1
2.2
2.3
CheckDim
2
2.1
15
Installing side
tracks Attention: Tracks must be installed
using CheckDim as outlined below!
Measurement taken from backs of
aluminum wheel guides
Do not remove fasteners until the
tracks are vertical and ready to be
fastened to the wall
2091709 / SG 5000U42 RE / 11.2023 15
70 Nm
(51.5 ft-lb)
60 Nm
(44.5 ft-lb)
2.3
60 Nm
(44.5 ft-lb)
2.4
2.2
3.3
Skip to step 2.3 if optional
component was not ordered
Hardware by others
16 2091709 / SG 5000U42 RE / 11.2023
3.1
3.2
3.3
3.4
X
≈150
(5-7/8) ≈150
(5-7/8)
≈400
(15-3/4)
≈400
(15-3/4)
≈400
(15-3/4)
X
3.4b
3.3
60 Nm
(44.5 ft-lb)
3.4a
3.2b3.2a
3
3.1
X
4
Installation position of lintel
seal is included on the yellow
label at the top of the tracks
Installing lintel seal
Hardware by others Hardware by others
Hardware by othersHardware by others
2091709 / SG 5000U42 RE / 11.2023 17
=
=
4.1
4.2
4.1
4.2
4.1
4.2
70 Nm
(51.5 ft-lb)
4
2.5; 3
19
Rest spiral on installation
support bolts to aide in
alignment of post bolts
Loosen wheel guide
support fasteners
Ensure that everything is aligned;
up-down and left-right
Align aluminum wheel guides.
Slide the splice bracket up and
center over the splice
Move the aluminum wheel
guide up until it butts against
the spiral guide. Re-tighten
the fasteners
Attention: Do not fully torque as
adjustments may be needed in the
next steps
Installing Spirals
18 2091709 / SG 5000U42 RE / 11.2023
5.1
5.2
5.3
5.1
5.2
5.3
5.4
5
5.1
5.2
185 (7-5/16)
340 (13-3/8)
17
3; 5
17
Drive axle installation
Do not torque completely to
allow adjustment in next steps
2091709 / SG 5000U42 RE / 11.2023 19
10 Nm
(7.5 ft-lb)
10 Nm
(7.5 ft-lb)
5.3
50 (1-15/16)50 (1-15/16)
105 (4-1/8)
50 (1-15/16) 50 (1-15/16)
50
(1-15/16) 50
(1-15/16)
105 (4-1/8) 105 (4-1/8)
The quantity of springs
depends on door size
Ensure pulley clamp is in the correct position
Ensure pulley clamp is in the correct position
20 2091709 / SG 5000U42 RE / 11.2023
20 Nm
(15 ft-lb)
20 Nm
(15 ft-lb)
DW
5.4
DW > 3500
(137-3/4)
DW > 5000
(196-7/8)
= =
Lift the shaft support until the shaft is level.
Tighten fasteners and add grease to shaft / support
Attention: Ensure shaft support is centered to avoid installation issues
for optional accessories.
There is no shaft support DW ≤ 3500 (11'-6")
Hardware by others Hardware by others
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Hormann Speed-Guardian™ 5000 42 Guide d'installation

Catégorie
Porte de garage
Taper
Guide d'installation