Dometic HC302, HC502 (R134a) Mode d'emploi

Taper
Mode d'emploi

Ce manuel convient également à

HC302, HC502
Medication refrigerator
Installation and Operating Manual. . . . . . . . 9
Medikamentenkühlschrank
Montage- und Bedienungsanleitung . . . . .23
Réfrigérateur pour médicaments
Instructions de montage
et de service . . . . . . . . . . . . . . . . . . . . . . . . .38
Medicamentenkoelkast
Montagehandleiding en
gebruiksaanwijzing . . . . . . . . . . . . . . . . . . .53
EN
DE
FR
NL
REFRIGERATION
SILENCIOHC
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 1 Mittwoch, 24. Februar 2021 1:34 13
© 2021 Dometic Group. The visual appearance of the contents of this manual is
protected by copyright and design law. The underlying technical design and the
products contained herein may be protected by design, patent or be patent
pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
All rights are reserved.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 2 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
3
2
1
5
7
8
6
HC302FS
HC502FS
HC302BIU
HC502BIU
3
3
4
1
3
4
21
2
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 3 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
4
1
2
1
1
1
2
2
2
ADCB
3
4
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 4 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
5
5
m
i
n
.
1
0
0
°
6
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 5 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
6
1.
2.
3.
7
4.
1.
1.
3.
2.
8
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 6 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
7
A
C
B
1
2 2 3
4
9
CD
AB
0
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 7 Mittwoch, 24. Februar 2021 1:34 13
HC302, HC502
8
820
422 FS: 450; BIU: 440
540
580
HC302
a
HC502
948
486 FS: 494; BIU: 484
552
592
b
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 8 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Explanation of symbols
9
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure
that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and
agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application
and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli-
cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and
others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and
warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit
dometic.com.
Table of contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6 Installing and connecting the refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . .14
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
8 Cleaning and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
10 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
11 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1 Explanation of symbols
D
!
!
DANGER!
Safety instruction: Indicates a hazardous situation that, if not avoided,
will result in death or serious injury.
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 9 Mittwoch, 24. Februar 2021 1:34 13
EN
Safety instructions HC302, HC502
10
A
I
2 Safety instructions
2.1 General safety
!
WARNING! Failure to obey these warnings could result in death
or serious injury.
Electrocution hazard
Ensure that the refrigerator has been installed by a qualified technician
in accordance with the Dometic installation manual.
Do not operate the refrigerator if it is visibly damaged.
If this refrigerator's power cable is damaged, it must be replaced by
the manufacturer, service agent or a similarly qualified person in order
to prevent safety hazards.
This refrigerator may only be repaired by qualified personnel.
Inadequate repairs may cause serious hazards.
Fire hazard
The refrigerant in the refrigerant circuit is highly flammable.
In the event of any damage to the refrigerant circuit:
Switch off the refrigerator.
Avoid naked flames and sparks.
Air the room well.
Explosion hazard
Do not store any explosive substances, such as spray cans with
propellants, in the refrigerator.
Health hazard
This refrigerator can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the refrigerator in a safe way and
understand the hazards involved.
Children shall not play with the refrigerator.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 10 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Safety instructions
11
Cleaning and user maintenance shall not be made by children without
supervision.
Children aged from 3 to 8 years are allowed to load and unload the
refrigerator.
!
CAUTION! Failure to obey these cautions could result in minor or
moderate injury.
Risk of crushing
Do not put your fingers into the hinge.
A
NOTICE! Damage hazard
Check that the voltage specification on the type plate is the same as
that of the power supply.
The refrigerator is not suitable for storing substances which are caustic
or contain solvents.
Keep the drainage outlet clean at all times.
Do not open the refrigerant circuit under any circumstances.
Only carry the refrigerator upright.
2.2 Operating the refrigerator safely
D
DANGER! Failure to obey these warnings will result in death or
serious injury.
Electrocution hazard
Do not touch exposed cables with your bare hands.
!
CAUTION! Failure to obey these cautions could result in minor or
moderate injury.
Electrocution hazard
Before starting the refrigerator, ensure that the power supply line and
the plug are dry.
Health hazard
The medicine and vaccines may only be stored in their original pack-
aging or in suitable containers.
Check if the required temperature range for the medicine or vaccine
suits with the temperature range of this appliance.
Opening the door for long periods can cause significant increase of
the temperature in the compartments of the refrigerator.
Clean regularly accessible drainage systems.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 11 Mittwoch, 24. Februar 2021 1:34 13
EN
Scope of delivery HC302, HC502
12
If the refrigerator is left empty for long periods:
Switch off the refrigerator.
Defrost the refrigerator.
Clean and dry the refrigerator.
Leave the door open to prevent mold developing within the
refrigerator.
A
NOTICE! Damage hazard
Do not use electrical devices inside the refrigerator unless they are
recommended by the manufacturer for that purpose.
Do not place it near naked flames or other heat sources (heaters, direct
sunlight, gas ovens etc.).
Ensure that the ventilation vents are not covered.
Never immerse the refrigerator in water.
Protect the refrigerator and the cable against heat and moisture.
3Scope of delivery
4 Intended use
The medication refrigeration (also referred to as refrigerator) is designed to keep
heat sensitive medicines according to DIN 58345 between +2 °C and +8 °C in
enclosed buildings, such as:
In hospitals, and health centers
In retirement homes, and nursing homes
The refrigerator is not suitable for installation in caravans or mobile homes.
The refrigerator is intended to be used either as a built-in appliance or as freestand-
ing refrigeration appliance. Refer to the installation instructions.
Quantity Description
1 Refrigerator
1 Handle
1 Battery (CR1632)
1 Installation and operating manual
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 12 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Technical description
13
The refrigerator is designed exclusively for cooling and storing medicines and vac-
cines in closed containers.
It's not suitable for storing any kind of body fluids like e.g. blood or plasma, or any
body parts like e.g. human organs.
It's not suitable for cooling and storing of beverages and foods, storing fresh
foods, or freezing foodstuffs.
This refrigerator is only suitable for the intended purpose and application in accor-
dance with these instructions.
This manual provides information that is necessary for proper installation and/or
operation of the refrigerator. Poor installation and/or improper operating or mainte-
nance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product
resulting from:
Incorrect assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare parts
provided by the manufacturer
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
5 Technical description
5.1 Function description
All materials used in the refrigerator are compatible for use with medicines.
The refrigerant circuit is maintenance-free.
The refrigerator is available as freestanding version (FS) and as built-in version (BIU).
The freestanding version (HC302FS, HC502FS) is intended for freestanding use.
The cooling unit cover protects the warm parts of the cooling units. The foot frame
with ventilation openings ensure sufficient ventilation. By removing the foot frame
and cooling unit cover the refrigerator can be used as a built-in version.
The built-in version (HC302BIU, HC502BIU) is intended to be mounted into furni-
ture. It doesn‘t have a foot frame or cooling unit cover.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 13 Mittwoch, 24. Februar 2021 1:34 13
EN
Installing and connecting the refrigerator HC302, HC502
14
The digital thermometer shows and stores the minimum and maximum inner
temperatures from the last reset so that you can check whether the medicines have
been stored at the appropriate temperatures.
5.2 Control elements
Key to fig. 2, page 3
6 Installing and connecting the
refrigerator
6.1 Unpacking the refrigerator
1. Check that the packaging is not damaged.
2. Remove the cardboard packaging.
3. Check that the refrigerator is not damaged.
No. in
fig. 1,
page 3
Explanation
1Door lock
2Door
3 Digital thermometer (see fig. 2, page 3)
4 Cooling unit cover
5 Drawers
6 Interior light
7Fan
8 Foot frame
No. Explanation
1 Current inner temperature (in °C)
2 Minimum inner temperature (in °C)
3 Maximum inner temperature (in °C)
4 Reset button
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 14 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Installing and connecting the refrigerator
15
If you find damage on the packaging or at the refrigerator resulting from
transport, report it immediately to the transportation firm.
6.2 Installing freestanding version
Observe the following instructions when installing:
1. Install the refrigerator so that the warm air produced can easily flow away, either
upwards or to the sides.
2. Place the refrigerator at the chosen place.
3. Leave the refrigerator to stand for at least four hours before you connect it to the
power supply so that the refrigerant can flow back into the compressor.
6.3 Installing built-in version
!
Observe the following instructions when installing:
Install the refrigerator so that the warm air produced can easily flow away (either
upwards or to the front, see fig. 3, page 4).
Key to fig. 3, page 4
Make sure that the refrigerator door is able to open at least 100°. Otherwise the
drawers cannot be used.
1. Check the dimensions of the refrigerator (fig. a, page 8 or fig. b, page 8).
2. Place the refrigerator according to fig. 4, page 4 or fig. 5, page 5.
3. Mount the refrigerator to the furniture by two screws through the fittings at the
bottom (fig. 6, page 5).
4. Leave the refrigerator to stand for at least four hours before you connect it to the
power supply so that the refrigerant can flow back into the compressor.
CAUTION!
Ensure the shelf is adequate to carry the total weight of the refrigerator
and the contents to be stored.
No. Explanation
1 Cold intake air
2 Hot waste air
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 15 Mittwoch, 24. Februar 2021 1:34 13
EN
Operation HC302, HC502
16
6.4 Connecting the refrigerator to the power supply
A
1. Connect the plug of the connection cable into the AC mains.
2. Insert the battery into the thermometer (see chapter “Replacing the battery of
the thermometer” on page 18).
The display turns on.
For the first two seconds the display will not show temperature values; it shows
--.-”. Then the temperature read from the sensor is shown.
6.5 Mounting and removing the door handle
1. Mount the handle as shown (fig. 7, page 6).
2. Remove the handle as shown (fig. 8, page 6).
7Operation
7.1 Before first use
Before first use, clean the refrigerator inside and outside with a damp cloth for
hygienic reasons (see also chapter “Cleaning and maintenance” on page 19).
7.2 Saving energy
Only open the medication refrigerator as often and for as long as necessary.
For optimal energy consumption, position the shelves and drawers according to
their position on delivery.
On a regularly basis, make sure the door seal still fits properly.
Clean dust and dirt from the condenser at regular intervals.
NOTICE!
Connect the refrigerator to a separate circuit to prevent
malfunctioning due to problems with other electrical equipment.
Never connect the refrigerator to a single socket with other electrical
equipment by means of a multi-socket.
UK only: The refrigerator is supplied with a plug fitted with 3 A fuse.
In case this fuse has to be to changed, a 3 A ASTA approved
(BS 1362) fuse must be used.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 16 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Operation
17
7.3 Switching on
!
A
After the first start, after replacing the battery or after switching off the refrigerator for
a longer time the display of the digital thermometer (fig. 2, page 3) shows the cur-
rent ambient temperature. When the inner temperature reaches the operating range
the thermometer should be reset to avoid showing wrong maximum temperature
value.
Press the reset button (fig. 2 4, page 3) for 5 s.
The thermometer has a blue backlight which makes the temperature values easier to
read.
Press the reset button (fig. 2 4, page 3) briefly.
The blue backlight lights for 2 s.
The thermometer stores the values of the minimum and maximum inner temperature
since the last reset. These values are deleted when the thermometer is reset or the
battery is changed.
7.4 Using the refrigerator
!
A
7.5 Setting the temperature
The refrigerator is equipped with an automatic temperature regulation function. The
temperature cannot be set.
CAUTION!
Do not store medicines and medicinal products before the operating
temperature range has been reached.
CAUTION!
Always leave some space between the refrigerated goods in the refrig-
erator to ensure efficient and even cooling. If the drawers are packed too
tightly there may be unacceptable temperature values.
NOTICE! Damage hazard
Only store heavy objects such as bottles or cans on the bottom of the
refrigerator.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 17 Mittwoch, 24. Februar 2021 1:34 13
EN
Operation HC302, HC502
18
7.6 Replacing the battery of the thermometer
Replace the battery of the thermometer as follows (fig. 9, page 7):
1. Pull the key (1) from the lock.
2. Remove the lock cover rosette using two standard screwdrivers.
3. Remove both screws (2) from front panel.
4. Push the front panel (3) a bit upwards and remove it by slightly pulling.
5. Remove the battery (4).
A
6. Insert the new battery (CR1632) in its holder.
7. Remount the front panel and lock cover rosette in reversed order.
7.7 Defrosting the refrigerator
I
Humidity can cause frost to form in the interior of the refrigerator or on the vaporizer.
A slight layer of frost or water droplets could form in the interior of the refrigerator if
it has been cooling for longer periods. This is normal because the moisture in the air
condenses to water when the temperature in the refrigerator drops. The refrigerator
is not defective.
The condensate flows out through a water drain duct into a water container at the
back of the refrigerator at top of the compressor, where it evaporates.
It is recommended to defrost the refrigerator every three weeks.
Proceed as follows:
1. Switch off the refrigerator: press the button for more than 5 seconds.
2. Disconnect the refrigerator from the mains.
3. Remove the drawers (see chapter “Removing the drawers” on page 19).
4. Leave the door open.
5. After defrosting wipe out the cabinet interior with a clean, damp cloth.
6. Assemble the drawers.
NOTICE!
Make sure the polarity is correct (the “+” must face up).
NOTE
In high ambient temperatures, the refrigerator may operate
continuously, which can lead to excessive formation of frost on the rear
wall of the refrigerator compartment.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 18 Mittwoch, 24. Februar 2021 1:34 13
EN
HC302, HC502 Cleaning and maintenance
19
7.8 Switching off and storing the refrigerator
If you do not intend to use the refrigerator for a long time, proceed as follows:
1. Disconnect the refrigerator from the mains.
2. Clean the refrigerator (see chapter “Cleaning and maintenance” on page 19).
3. Leave the door slightly open.
This prevents smells from building up.
7.9 Removing the drawers
You can remove the drawers, e.g. for cleaning.
Proceed as follows (fig. 0, page 7):
1. Open the door (A).
2. Pull out the drawer (B).
3. Push the fixing pins from the outside to the inside (C).
4. Remove the drawer (D).
5. Assemble the drawers in reverse order.
8 Cleaning and maintenance
!
A
Clean the refrigerator regularly and as soon as it becomes dirty with a damp
cloth.
Make sure that no water drips into the seals. This can damage the electronics.
Wipe the refrigerator dry with a cloth after cleaning.
Check the condensate drain regularly.
WARNING! Electrocution hazard
Always disconnect the refrigerator from the mains before you clean and
service it.
NOTICE! Damage hazard
Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the refrigerator.
Never use hard or sharp tools to remove ice or to free objects frozen
onto the device.
Do not use any mechanical tools or any other tools to speed up the
defrosting process.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 19 Mittwoch, 24. Februar 2021 1:34 13
EN
Troubleshooting HC302, HC502
20
Clean the condensate drain when necessary. If it is blocked, the condensate
collects on the bottom of the refrigerator.
Clean the door seals regularly.
Freestanding version: Clean the grid of the condenser and the compressor on the
back of the refrigerator with a vacuum cleaner regularly.
9 Troubleshooting
Water in or under the refrigerator
Display signals
Fault Possible cause Remedy
Water is leaking into the
inside of the
refrigerator.
The condensate drain duct is
clogged.
Clean the drain.
Medicines are preventing the water
from flowing to the collector.
Make sure that medicines
do not touch the rear
wall.
Water is leaking onto
the floor.
There is too much water in the water
container.
Clean the water
container.
Signal Explanation
General error
The display blinks each
second.
The display shows alternately the current inner temperature and
the active error code (fig. 2 1, page 3) (E1 or E2, see below).
Sensor failure
The display blinks and
shows “E1”.
The minimum and maximum values will be kept as the last known
values.
Low battery
The display blinks and
shows “E2” alternately
with the current tem-
perature.
The minimum and maximum inner temperatures are still visible
and will be updated from the current inner temperature reading.
DometicHC302-HC502_IOM_4445102103_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 20 Mittwoch, 24. Februar 2021 1:34 13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Dometic HC302, HC502 (R134a) Mode d'emploi

Taper
Mode d'emploi
Ce manuel convient également à