Garland 36ER33-88 Owner Instruction Manual

Catégorie
Fours
Taper
Owner Instruction Manual
Part # 4525587 Rev 4 (29 April 14)
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using
genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or
which has been modified or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized
service agents, please refer to the Garland web site at http://www.garland-group.com. The information contained
herein, (including design and parts specifications), may be superseded and is subject to change without notice.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER.
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained by consulting
your local gas supplier.
All 24, 36, 48, & 60-inch wide models.
INSTALLATION AND
OPERATION MANUAL
GARLAND GF SENTRY SERIES
GAS RESTAURANT RANGES
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
Españo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Página 43
Garland Commercial Ranges, Ltd.
1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
General Inquires 1-95-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-4526
Canada or USA Parts/Service 1-800-427-6668
Part # 4525587 Rev 4 (29 April 14)Page 2
IMPORTANT INFORMATION
WARNING:
This product contains chemicals known to the State of California to cause cancer and/or birth de-
fects or other reproductive harm. Installation and servicing of this product could expose you to air-
borne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic
fibers is known to the State of California to cause cancer. Operation of this product could expose
you to carbon monoxide if not adjusted properly. Inhalation of carbon monoxide is known to the
State of California to cause birth defects or other reproductive harm.
Keep appliance area free and clear of combustibles.
Part # 4525587 Rev 4 (29 April 14) Page 3
TABLE OF CONTENTS
IMPORTANT INFORMATION. . . . . . . . . . . . . 2
DIMENSIONS AND SPECIFICATIONS . . . . . 4
Base Model Designations & Total Input Rates . . 5
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Gas Pressure & Individual Burner Input Rates . . 6
North America . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CE & General Export . . . . . . . . . . . . . . . . . . . . . . 6
Reduced Input Rates . . . . . . . . . . . . . . . . . . . . . 6
Note: Manifold pressure is to measured at the
test spigot located on the 3/4” gas manifold
pipe.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Australia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Gas Inlet Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CE Approved Gas Categories . . . . . . . . . . . . . . . . . 7
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . 8
Rating Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . 9
Siting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Appliances Equipped With Casters . . . . . . . . . . . . 9
Appliances Equipped With Legs . . . . . . . . . . . . . . 9
Installing Shelf To Backguard . . . . . . . . . . . . . . . . . 9
Backguard With High Shelf Or Salamander
Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . 9
Ventilation Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Statutory Regulations . . . . . . . . . . . . . . . . . . . . . . . 11
Australia Speci c Clause . . . . . . . . . . . . . . . . . . . . . 11
Electrical Connection Settings
(Where Applicable) . . . . . . . . . . . . . . . . . . . . . . . . . 11
Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Final Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Optional Interconnect Gas Kit . . . . . . . . . . . . . . . 12
TESTING AND ADJUSTMENT . . . . . . . . . . . 13
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Flame Failure Technology . . . . . . . . . . . . . . . . . . . 14
How Flame Failure Technology Works . . . . . . . . 14
Burner Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Open Top burners . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Hot Tops and Front-Fired Target Tops . . . . . . . . 15
Ovens (Standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Convection Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Thermostat Controlled Griddles . . . . . . . . . . . . . 17
Griddle/Broiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Range Shut down . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
PRODUCT APPLICATION INFORMATION 18
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Open Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Hot Tops. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
MAINTENANCE AND CLEANING . . . . . . . . 19
Seasoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Griddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cast Iron top Grates . . . . . . . . . . . . . . . . . . . . . 19
Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Oven Interior (Porcelain Enamel) . . . . . . . . . . . . . 19
Open Top Burners . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cast Iron Top & Grates . . . . . . . . . . . . . . . . . . . . . . .20
Hot Tops and Front-Fired Target Hot Tops . . . .20
Griddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Part # 4525587 Rev 4 (29 April 14)Page 4
DIMENSIONS AND SPECIFICATIONS
Top View
Model widths vary depending on model series.
(See Chart on left)
2-1/4"
[57mm]
27-1/4"
[692mm]34-1/2"
[876mm]
5"
[127mm]
3-1/2"
[89mm]
ELECTRICAL PLUG
(WHERE APPICALBE)
Modular Top Models GF24-_T or GF36-_T Side View
Series Width
GF24 600mm (23-5/8”)*
GF36 900mm (35-2/2”)* Shown
GF48 1200mm (47-1/4”)
GF60 1500mm (59-1/2”)
*Range base or modular top
9-3/8" [238mm]
15-5/8"
[396mm]
GF Series Side View
(Showing convection base where applicable).
13-7/8"
[352mm]
ADD WHEN
DOOR OPEN
39-3/8"
[1000mm]
LOW PROFILE
BACKGUARD
51"
[1290mm]
STD BACKGUARD
W/HIGH SHELF
(OPTIONAL)
3-7/8" [98mm]
ADD FOR
CONVECTION OVEN
12-1/8"
[307mm]
18-3/8"
[466mm]
31-1/8"
[791mm]
GF Series 60” Raised Griddle/Broiler Side View
CLEARANCE FROM TOP OF GRIDDLE PLATE
TO OPTIONAL HIGH SHELF 14-3/4" [374mm]
CLEARANCE FROM TOP OF GRATE
TO OPTIONAL HIGH SHELF 18-3/8" [466mm]
13-7/8"
[352mm]
ADD WHEN
DOOR OPEN
12-1/8"
[307mm]
31-1/8"
[791mm]
3-7/8" [98mm]
ADD FOR
CONVECTION OVEN
41"
[1041mm]
LOW PROFILE
BACKGUARD
1"
[25mm]
GAS
INLET
51"
[1296mm]
STD BACKGUARD
W/HIGH SHELF
Part # 4525587 Rev 4 (29 April 14) Page 5
DIMENSIONS AND SPECIFICATIONS continued
Base Model Designations & Total Input Rates
Model #* Description
Input
Natural Gas Propane Gas
BTU/Hr
CE
Rating
kW
BTU/Hr
CE
Rating
kW
GF/GFE24-4L 24” (600mm) nominal size unit, 4 open burners, space saver oven 136,000 41.50 132,000 39.70
GF24-T 24” (600mm) nominal size unit, 4 open burners, modular top 104,000 30.40 104,000 30.40
GF/GFE36-6R 36” (900mm) nominal size unit, 6 open burners, standard oven 194,000 56.70 188,000 54.90
GFE36-6C 36” (900mm) nominal size unit, 6 open burners, convection oven 194,000 56.70 188,000 54.90
GF36-T 36” (900mm) nominal size unit, 6 open burners, modular top 156,000 45.60 156.000 45.60
GF/GFE36-TTR
36” (900mm) nominal size unit, 2 Front- red Target Hot Top
sections, standard oven
100,000 29.10 94,000 25.50
GFE36-TTC
36” (900mm) nominal size unit, 2 Front- red Target Hot Top
sections, convection oven
100,000 29.10 94,000 25.50
GF/GFE48-LL
48” (1200mm) nominal size unit, 8 open burners,
2 space saver ovens
272,000 79.60 264,000 77.20
GF/GFE60-10RR
60” (1500mm) nominal size unit, 10 open burners,
2 standard ovens
336,000 98.20 324,000 94.60
GFE60-10RC
60” (1500mm) nominal size unit, 10 open burners, 1 standard &
1 convection oven
336,000 98.20 324,000 94.60
GFE60-10CC
60” (1500mm) nominal size unit, 10 open burners,
2 convection ovens
336,000 98.20 324,000 94.60
GF/GFE60-6R24RR
60” (1500mm) nominal size unit, 6 open burner, 24” (610mm),
raised griddle/broiler, 2 standard ovens
265,000 76.80 253,000 73.20
GFE60-6R24RC
60” (1500mm) nominal size unit, 6 open burner, 24” (610mm),
raised griddle/broiler, 1 standard & 1 convection oven
265,000 76.80 253,000 73.20
GFE60-6R24CC
60” (1500mm) nominal size unit, 6 open burner, 24” (610mm),
raised griddle/broiler, 2 convection ovens
265,000 76.80 253,000 73.20
GF/GFE60-6R24RS
60” (1500mm) nominal size unit, 6 open burner, 24” (610mm),
raised griddle/broiler, 1 standard oven & 1 storage section
227,000 65.70 221,000 63.90
GFE60-6R24CS
60” (1500mm) nominal size unit, 6 open burner, 24” (610mm),
raised griddle/broiler, 1 convection oven & 1 storage section
227,000 65.70 221,000 63.90
*Models beginning with GFE pre x have electric spark ignition systems for pilots.
Rates are for installations up to 2000’ (610m) above sea level
Each 12”(305mm) Hot Top section is 5.3kW, replacing 2 Open Burners (7.6kW each)
Clearances
Clearances Applicable For All Models Except Where Noted
Surface Sides Range Sides Modular Top Rear
Combustible Wall Minimum 14” (356mm) 6” (152mm) 6” (152mm)
Non-Combustible Wall Minimum 0” 0” 0”
Part # 4525587 Rev 4 (29 April 14)Page 6
Gas Pressure & Individual Burner Input Rates
North America
Garland GF Series
Nat.,
4.5” wc Manifold
LPG,
10” wc Manifold
BTU/h BTU/h
Open Top (Flame Failure) 26,000 26,000
Target Top 36” models only, per section 3@10,333 3@10,333
Hot Top FF (in lieu of 2 Open Top Burners) 18,000 18,000
Griddle (in lieu of 2 Open Top Burners)(Tstat) 18,000 18,000
Raised Griddle Broiler (3 burners) 3 @11,000 3 @11,000
26” Oven Burner (H-Cast)(Standard or Convection) 38,000 32,000
Space Saver Oven (H-Cast) 32,000 28,000
CE & General Export
Garland GF Series
Nat. (G20),
11.2 mbar Manifold
LPG (G31),
24.9 mbar Manifold
kW kW
Open Top (Flame Failure) 7.6 7.6
Hot Top FF (in lieu of 2 Open Top Burners) 5.3 5.0
Target Top “36” models, only per section [email protected] [email protected]
Griddle (in lieu of 2 Open Top Burners)(Tstat) 5.3 5.3
Raised Griddle Broiler (3 burners) 3 @ 3.0 3 @ 3.0
26” Oven Burner (H-Cast)(Standard or Convection) 11.1 9.3
Space Saver Oven (H-Cast) 9.4 8.2
Reduced Input Rates
Approximate input ratings for adjustable top burners set at LOW:
Garland GF Series
NAT(G20) LPG(G31)
kW m
3
/h kW m
3
/h
Open Top Burner (Flame Failure) 2.0 0.21 4.2 0.17
Hot Top (Flame Failure) 2.75 0.29 4.9 0.20
Griddle (Tstat) 3.0 0.32 2.0 0.08
Raised Griddle Broiler (Total Of 3 Burners) 3.0 0.32 5.9 0.24
Target Top 2.7 0.28 4.0 0.16
Note: Manifold pressure is to measured at the test spigot located on the /” gas manifold pipe.
DIMENSIONS AND SPECIFICATIONS continued
Part # 4525587 Rev 4 (29 April 14) Page 7
DIMENSIONS AND SPECIFICATIONS continued
Australia
Garland GF Series
Nat., 1.0kPa Manifold LPG, 2.49 kPa Manifold
MJ/H Injector MJ/H Injector
Open Top (Flame Failure) 30.6 37 (2.64mm) 28.49 53 (1.51mm)
Hot Top FF (in lieu of 2 Open Top Burners) 19.0 47 (1.99mm) 18.15 1.2mm
Front Fired Hot Top (Target Top) 36.5 52(1.61mm) 36.5 1.0mm
Griddle (in lieu of 2 Open Top Burners)(Tstat) 19.0 47 (1.99mm) 18.15 1.2mm
Raised Griddle Broiler (3 burners) 30.0 47 (1.99mm) 34.82 61 (0.99 mm)
26” Oven Burner (H-Cast)(Standard) 40.09 30 (3.26mm) 33.76 50 (1.78mm)
26” Oven Burner (H-Cast) (Convection) 40.09 30 (3.26mm) 32.18 51 (1.7mm)
Space Saver Oven (H-Cast) 33.7 33 (2.87mm) 27.96 52 (1.61mm)
Gas Inlet Size
Model Width Connection
Connection CE Models
(ISO7-1)
23-5/8” (600mm) &
35-1/2” (900mm)
3/4” NPT
Rear Gas Connection
3/4” (19.1mm) BSPT
47-1/4” (1200mm) &
59-1/2” (1500mm)
1” NPT
Rear Gas Connection
1” (25.4 mm) BSPT
CE Approved Gas Categories
Country Gas Category Gas Type Pressure (mbar)
AT, CH, CY, CZ, DK, EE, ES, FI, GB, GR, HR, IE, IT,
LT, LV, NO, PT, RO, SE, SI, SK, TR
I
2H
G20 20
BE, CH, CZ, ES, FR, GB, GR, HR, IE, IT, LU, PL, PT I
3P
G31 37
AT, BE, CH, CZ, DE, ES, FR, GB, HU, NL I
3P
G31 50
CH, CZ, ES, GB, GR, HR, IE, IT, PT II
2H3P
G20 20
G31 37
CH, CZ, ES, GB, II
2H3P
G20 20
G31 50
Part # 4525587 Rev 4 (29 April 14)Page 8
INTRODUCTION
1. Check crate for possible damage sustained during transit.
Carefully remove unit from crate and again check for
damage. Any damage to the appliance must be reported
to the carrier immediately.
2. The wires for retaining packing material must be
removed from units. Any protective material covering
stainless steel parts must also be removed.
3. All equipment is supplied with 6” (152mm) legs unless
speci ed to be dais for cove base mounting, casters
or deck mount  anged feet. Units 48” (1200mm) and
60” (1500mm) wide have legs factory mounted. Base
mounting is required when range is being installed on a
combustible  oor.
4. The type of gas and supply pressure that the equipment
was set-up for at the factory is noted on the rating plate
and on the packaging. This type of gas supply must be
used.
5. Do not remove permanently a xed labels, warnings or
rating plates from the appliance, for this may invalidate
the manufacturers warranty.
Rating Plate
All burner input rates are shown on the rating plate, which is
located behind the lower front drop down panel under the
oven door.
Safety Information
Warning: Accessible parts may become hot during use.
Young children should be kept away.
This appliance is for professional use and should only be
used by quali ed personnel
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Part # 4525587 Rev 4 (29 April 14) Page 9
INSTALLATION
This product has been certi ed as commercial cooking
equipment and must be installed by professional personnel
as speci ed. THIS APPLIANCE IS NOT RECOMMENDED FOR
RESIDENTIAL INSTALLATION.
Garland suggest installation, maintenance and repairs
should be performed by your local Garland/US Range
authorized service agency, when ever possible.
Siting
The  oor on which the appliance is to be sited must
be capable of adequately supporting the weight of
the appliance and any ancillary equipment. Units with
ovens must be  tted with legs or casters if installed on a
combustible  oor. Adequate clearance must be provided for
servicing and proper operation.
Appliances Equipped With Casters
1. The installation shall be made with a connector that
complies with the Standard for Connectors for Moveable
Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda
Z21.69B-2006/CSA 6.16B-2006 (or latest edition), and a
quick-disconnect device that complies with the Standard
for Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/
CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005
(or latest edition).
2. The front casters of the appliance are equipped with
brakes to limit the movement of the appliance without
placing any strain on the connector or quick disconnect
device or its associated piping.
3. Please be aware that required restraint is attached to a
cut out hole in side panel, and if disconnection of the
restraint is necessary, be sure to reconnect the device
after the appliance has been returned to its original
position.
Appliances Equipped With Legs
1. Raise the front of the appliance and block. Do not lay the
appliance on its back.
2. Legs are threaded to be easily screwed into the holes
provided on the bottom of the range.
3. Once legs have been attached and secured they can
be adjusted to level the appliance and compensate for
uneven  ooring.
Installing Shelf To Backguard
Note: Shelf may be installed before or after installing the
backguard to the range.
1. Loosen 4 bolts on the front of the backguard
approximately 1/4” (6mm).
2. Align the 4 slotted holes on the back of the shelf with the
4 bolts on the backguard.
3. Slide the shelf downward until the 4 bolts are engaged in
the slotted portion of the keyhole.
4. Tighten the 4 bolts to secure the shelf.
5. On 60” units only, install a sheet metal screw though the
hole in the underside of the shelf into the backguard and
tighten.
SHELF
BACKGUARD
MOUNTING
BOLTS
SHEETMETAL
SCREW
Backguard With High Shelf Or Salamander
Mounting Instructions
1. Rear of the range must be easily accessible.
2. Please refer to the installation instructions included with
the salamander for further instructions on these units.
3. Place the backguard or high shelf on the rear of the
range, slipping the support brackets into the openings in
the main body sides.
4. For ranges with griddles, care must be taken when
mounting the backguard or high shelf. The front panel
of the stainless steel backguard or high shelf has an
extruding lip at the bottom. This lip must NOT go over
the griddle back splash, if it does the backguard will not
t properly and the range will not  ue properly. Refer to
illustration for proper installation.
Part # 4525587 Rev 4 (29 April 14)Page 10
DETAIL
AREA
BACKGUARD
SPLASH
GUARD
Correct Installation
CLIP GRIDDLE SPLASH GUARD
ONTO BACK FLANGE OF GRIDDLE
(SHIPPED ON TOP OF GRIDDLE)
BACKGUARD LIP GOES
BEHIND BACK FLANGE
OF GRIDDLE & OVER
ANGLE FLANGE
FLUSH WITH
SIDE PANEL
ANGLE
FLANGE
Incorrect Installation
NOT FLUSH
WITH
SIDE PANEL
BACKGUARD
LIP ON BACK
FLANGE
OF GRIDDLE
5. Securely fasten the support brackets to the burner box
sides with (4sheet metal screws provided).
Upright
Main Body
Side
Sheet Metal
Screws (4 Req'd)
Ventilation Air
The following notes are intended to give general guidance.
For detailed recommendations, refer to the applicable
code(s) in the country of destination. These appliances shall
be installed in a room with su cient ventilation to prevent
the occurrence of hazardous concentrations of combustion
by-products.
The room containing the appliance is required to have a
permanent vent. The minimum e ective area of the vent is
related to the maximum rated heat input of the appliance
and shall be 4.5 cm
2
per kW in excess of 7 kW.
Proper ventilation is critical for optimum performance. The
ideal method of ventilating open-top equipment is the use
of a properly designed canopy that should extend six inches
(152 mm), beyond all sides of the appliance(s) and six feet, six
inches (1981mm) above the  oor.
Air vents should be of such a size as to compensate for the
e ects of any extract fan in the premises. A strong exhaust
will create a vacuum in the room. For an exhaust vent to work
properly, replacement air must be equal to the amount of air
exhausted. An imbalance between exhaust and replacement
air can cause degradation in the appliances performance.
All gas burners and pilots need su cient air to operate. Large
objects should not be placed in front of the appliance(s) that
would obstruct the  ow of air into the front.
INSTALLATION Continued
Part # 4525587 Rev 4 (29 April 14) Page 11
Statutory Regulations
In European countries, installation must be carried out by
a competent person and in accordance with the relevant
regulations, codes of practice and the related publications of
the country of destination.
In the United States, the installation must conform to the
National Fuel Gas Code ANSI Z223.1, or latest edition, NFPA
No.54 - latest edition/or local code to assure safe and e cient
operation. In Canada, the installation must comply with CSA
B149.1 and local codes.
Australia Speci c Clause
This appliance must be installed in accordance with the
manufacturers instructions, local gas  tting regulations
and requirements of AS 5601 installation code. All burner
adjustments and setting should be made by a quali ed gas
technician.
Electrical Connection Settings
(Where Applicable)
IMPORTANT- This appliance must be electrically grounded in
accordance with local codes, or in the absence of local codes
with the National Electrical Code.
220/240 Volt Convection Oven Models
When the appliance is ordered and equipped for 220/240
volt operation, the supply line must be connected to the
wiring terminations located inside the terminal box at the
rear of the appliance.
For ease of attaching the supply line, there is a removable
cover on the terminal box.
Permanent connection to the electrical service must comply
with local codes, or in the absence of local codes, with the
national electrical code.
Gas Connection
The local gas authority should be consulted at the
installation planning stage in order to establish the
availability of an adequate supply of gas and to ensure
that the meter is adequate for the required  ow rate. The
pipe work from the meter to the appliance must be an
appropriate size.
INSTALLATION Continued
All  xed (non-mobile) appliances MUST be  tted with an
accessible upstream gas shut o valve as a means of isolating
the appliance for emergency shut o and for servicing. A
union or similar means of disconnection must be provided
between the gas-cock and the appliance.
A manually operable valve must be  tted to the gas supply
to the kitchen to enable it to be isolated in an emergency.
Wherever practical, this shall be located either outside the
kitchen or near to an exit in a readily accessible position.
Where it is not practical to do this, an automatic isolation
valve system shall be  tted which can be operated from a
readily accessible position near to the exit.
In locations where the manual isolation valve is  tted or the
automatic system can be reset this notice MUST be posted:
ALL DOWNSTREAM BURNER AND PILOT VALVES MUST
BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE
SUPPLY. AFTER EXTENDED SHUT OFF, PURGE BEFORE
RESTORING GAS.
Installation Notes
Before assembly and connection, check gas supply.
A. The type of gas for which the unit is equipped is stamped
on the rating plate located behind the lower front
panel. Connect a unit stamped “NAT only to natural gas;
connect one stamped “PRO” only to propane gas.
B. If it is a new installation have the gas authorities check
meter size and piping to assure that the unit is supplied
with the necessary amount of gas pressure required to
operate the unit.
C. If it is additional or replacement equipment have the gas
authorities check pressure to make certain that existing
meter and piping will supply fuel to the unit with no
more than 0.15 Kpa pressure drop.
D. Make certain new piping and connections have been
made in a clean manner and have been purged so that
piping compound, chips, etc. will not clog pilots, valves or
burners. Use pipe joint compound approved for natural
and lique ed petroleum gases.
NOTE: Gas pressure should be checked when the unit is
installed with all other equipment on the same line turned
on. The operating manifold gas pressure must be the same
as that speci ed on the rating plate. If necessary, pressure
adjustment may be made at the pressure regulator supplied
with the appliance.
Part # 4525587 Rev 4 (29 April 14)Page 12
The appliance pressure regulator provided by the factory
is pre-set to the correct manifold pressure. The manifold
pressure may require veri cation and adjustment at the
installation. Allow at least one burner to be ignited and
operating while checking manifold pressure at the test
spigot located on the appliance manifold, and adjust the
appliance pressure regulator accordingly.
The appliance and its individual shut-o valve must be
disconnected from the gas supply piping system during any
pressure testing of that system where pressures are in excess
of 1/2 PSIG (3.45kPa.)
Final Preparation
NOTE: Your new range has a plastic coating to help protect
the  nish from scratches during shipping. This protective
plastic  lm should be peeled o prior to starting the range.
Optional Interconnect Gas Kit
To interconnect range mount salamanders with range
The GF series Garland range can be equipped with a range
mount gas salamander. Salamanders can be plumbed
independently or be interconnected with the range. See
Drawing for various options for mounting onto a 36”
(900mm) a 48” (1200mm) or a 60” (1500mm) range.
INSTALLATION Continued
MARK HOLE LOCATIONS AND MOUNT
SUPPORT BRACKET (ITEM 6 - 2640700) TO RANGE
BACK WITH (2)#10-16 TEKS SELF-DRILL/TAP
SCREWS (ITEM 11 - F67 - NOT SHOWN) PROVIDED.
ATTACH SUPPORT CLAMP (ITEM 7 - 2640800)
TO SUPPORT BRACKET ( ITEM 6 - 2640700)
WITH (2)#10-24 SELF-TAPPING SCREWS (ITEM 12
F32 - NOT SHOWN) PROVIDED.
15
5
2
9
1
4
10
14
3
8
13
REGULATOR - 4.5" w.c. NATURAL GAS
OR 10.0" w.c. PROPANE GAS
(SUPPLIED WITH RANGE)
REGULATOR - 6.0"w.c. NATURAL GAS
OR 10.0"w.c. PROPANE GAS
(SUPPLIED WITH SALAMANDER/
CHEESEMELTER)
TO INLET OF SALAMANDER/
CHEESEMELTER MANIFOLD
2
2
3
SUPPLIED WITH RANGE
SUPPLIED WITH RANGE
5
CUT TUBING (ITEM 15 - 4531608) TO SIZE AS REQUIRED
TO SUIT SALAMANDER/CHEESEMELTER TOP OR REAR
MANIFOLD INLET CONNECTION
6
7
TO INLET OF RANGE
MANIFOLD
1" NPT GAS SUPPLY
CONNECTION
15 4531608
3/4" X 51" X 33" TUBING
1
14
G01738-11
3/4" NPT X 3.5" PIPE NIPPLE
1
13
2127503/2127500
6.0"wc 3/4"NPT REG. NATURAL GAS/10"wc 3/4" NPT REG. PROPANE GAS - SUPPLIED WITH SALAMANDER/CHEESEMELTER
1
12
F32
SCREW-10-24X1/2" PAN HD SELF-TAP TYPE F (NOT SHOWN)
2
11
F67
SCREW - #10-16 X 1/2" HEX WASHER HEAD TEKS SELF DRILL/TAP (NOT SHOWN)
2
10
G03716-1
3/4" NPT X 3/4" NPT X 1" NPT REDUCING TEE
1
9
G01738-5
3/4" NPT X 6.5" PIPE NIPPLE
1
8
G01474-9
3/4" NPT X 1/2" NPT 90 DEG. REDUCING ELBOW
1
7
2640800
PIPE SUPPORT BRACKET CLAMP
1
6 2640700
PIPE SUPPORT BRACKET
1
5 3013000
3/4" CC X 3/4" NPT STRAIGHT FITTING
2
4
G01963-1
3/4" NPT PIPE UNION
1
3
G01474-5
90 DEGREE ELBOW 3/4" NPT (ONE SUPPLIED WITH RANGE)
2
2
G01738-14
3/4" NPT X 2IN PIPE NIPPLE (ONE SUPPLIED WITH RANGE)
3
1
NAT: 2127502/4525047
PRO: 2127500/4525048
4.5"wc 3/4"NPT/3/4" ISO 7-1 REG. NATURAL GAS OR 10"wc 3/4"NPT/3/4" ISO 7-1 REG. PROPANE GAS - SUPPLIED W/RANGE
1
ITEM NO.
PART NUMBER
DESCRIPTION
QTY
Optional Interconnect Gas Kit
36in (900mm) G/U/X
Part # 4531606
Part # 4525587 Rev 4 (29 April 14) Page 13
INSTALLATION Continued
TESTING AND ADJUSTMENT
Testing
All  ttings and pipe connections must be tested for
leaks. Use approved gas leak detectors, soap solution or
equivalent, checking over and around all the  ttings and
pipe connections. DO NOT USE A FLAME! Accessibility to
all gas lines and  ttings require that valve panel(s) lower
front panel(s), and/or oven rack(s) be removed. It may be
necessary to remove, or at least raise and securely prop
griddle(s), hot top(s), and/or top grate(s). All parts removed,
(including fasteners), should be stored safely for re-
installation.
1. Be sure that all valves and thermostats are in the “OFF”
position.
2. Turn on the main gas supply valve. Light all top section
pilots.
3. Leak test all valves and  ttings as described at the
beginning of this section. Correct any leaks as required
and recheck.
4. Light the oven pilot.
5. Set the oven thermostat to maximum. Leak test all valves
and  ttings as described at the beginning of this section.
Correct any leaks as required and recheck.
6. Shut o all valves and set thermostat dials to “OFF” or
lowest position. All units are tested and adjusted at the
factory, however, burners and pilots should be checked
upon installation and adjusted if necessary.
18
17
7
3
2
4
8
11
15
6
5
16
17
4
9
10
TO INLET OF SALAMANDER/
CHEESEMELTER MANIFOLD
NOTE: CUT TUBING (ITEM 18 - 4531608) TO SIZE AS REQUIRED
TO SUIT SALAMANDER/CHEESEMELTER TOP OR REAR
MANIFOLD INLET CONNECTION
SUPPLIED WITH
RANGE
REGULATOR - 4.5"w.c.
NATURAL GAS OR 10.0"w.c.
PROPANE GAS (SUPPLIED
WITH RANGE)
REGULATOR - 6.0"w.c.
NATURAL GAS OR 10.0"w.c.
PROPANE GAS (SUPPLIED
WITH SALAMANDER/CHEESEMELTER)
MARK HOLE LOCATIONS AND MOUNT
SUPPORT BRACKET (ITEM 9 - 4531602) TO
BACK WITH (2) #10-16 TEKS SELF-DRILL/TAP
SCREWS (ITEM 14 - F67 - NOT SHOWN) PROVIDED.
ATTACH SUPPORT CLAMP (ITEM 10 - 2640800)
TO SUPPORT BRACKET (ITEM 9 - 4531602)
WITH (2) #10-24 SELF-TAPPING SCREWS (ITEM 1
F32 - NOT SHOWN) PROVIDED
SUPPLIED WITH
RANGE
4
TO INLET OF RANGE
MANIFOLD
1" NPT GAS SUPPLY
CONNECTION
12
6
13
6
17
9
10
FOR LEFT-MOUNTED SALAMANDER/CHEESEMELTER
SUBSTITUTE COMPONENTS SHOWN FOR ITEM 17 CIRCLED IN ADJACENT VIEW
TO INTER-CONNECT TUBING ( ITEM 18 - 4531608)
TO OUTLET OF SALAMANDER/
CHEESEMELTER REGULATOR
ATTACH SUPPORT CLAMP (ITEM 10 - 2640800)
TO SUPPORT BRACKET (ITEM 9 - 4531602)
WITH (2) #10-24 SELF-TAPPING SCREWS (ITEM 1
F32 - NOT SHOWN) PROVIDED
MARK HOLE LOCATIONS AND MOUNT
SUPPORT BRACKET (ITEM 9 - 4531602 ) TO RANGE
BACK WITH (2) #10-16 TEKS SELF-DRILL/TAP
SCREWS (ITEM 14 - F67 - NOT SHOWN) PROVIDED.
18 4531608
3/4" X 51" X 33" TUBING
1
17 3013000
3/4" CC X 3/4" NPT STRAIGHT FITTING
2
16
G01474-9
3/4" NPT X 1/2" NPT 90 DEG. REDUCING ELBOW
1
15
G01738-11
3/4" NPT X 3.5" PIPE NIPPLE
1
14
F67
SCREW - #10-16 X 1/2" HEX WASHER HEAD TEKS SELF-DRILL/TAP (NOT SHOWN)
4
13
G01738-14
3/4" NPT X 2.000 PIPE NIPPLE
1
12
G01738-16
3/4" NPT X 22.750 PIPE NIPPLE
1
11 3012800
1" NPT X1" NPT X 3/4" NPT REDUCING TEE
1
10 2640800
PIPE SUPPORT BRACKET CLAMP
2
9 4531602
PIPE SUPPORT BRACKET 48/60
2
8 4530189
1" NPT PIPE UNION
1
7
076029-171
1" NPT 90 DEGREE ELBOW(SUPPLIED WITH RANGE)
1
6
G01474-5
90 DEGREE ELBOW 3/4" NPT
3
5
G01738-5
3/4" NPT X 6.5" PIPE NIPPLE
1
4
076029-204
1" NPT X 2" PIPE NIPPLE (ONE SUPPLIED WITH RANGE)
3
3
2127503/2127500
4.5"wc 3/4"NPT REG. NATURAL GAS/10"wc 3/4"NPT REG. PROPANE GAS - PROVIDED WITH SALAMANDER/CHEESEMELTER
1
2
NAT: 4522421/4525049
PRO: 4522422/4525050
4.5" wc 1" NPT/ 1" ISO 7-1 REG. NATURAL GAS OR 10"wc 1"NPT/1" ISO 7-1 REG. PROPANE GAS - PROVIDED WITH RANGE
1
1
F32
SCREW - #10-24 X 1/2" PAN HD SELF-TAP TYPE F (NOT SHOWN)
4
ITEM NO.
PART NUMBER
DESCRIPTION
QTY
Optional Interconnect Gas Kit
48in (1200mm) & 60in (1500mm) G/U/X
Part # 4531606
Part # 4525587 Rev 4 (29 April 14)Page 14
Flame Failure Technology
The Garland GF series gas range has total  ame failure (also
referred to as  ame safety) technology. It is a simple system
that monitors the existence of a gas  ame. It can be used on
most gas appliances and will turn o the gas supply to any
burner using the system when a pilot ignition  ame is not
present.
Flame failure systems have been available for many years
and it is the “CE” agency standard accepted for European gas
appliance approvals. In North America this technology is
gaining greater acceptance and various levels of government
are making it mandatory in schools and other government
institutions.
How Flame Failure Technology Works
For gas restaurant ranges, there are three principles at
work in a  ame failure system, they are a safety valve, the
thermocouple and the pilot.
Safety Valve
The SIT control used on the new Garland series of restaurant
ranges operates both as the mechanism to control the
oven temperature (thermostat) and the safety valve for the
ame failure system. This valve contains a magnet which
when electrically charged, will hold a check valve in an open
state allowing for gas to  ow through the valve as required
by either the pilot or main burner. The magnet is charged
through an electrical signal sent from the thermocouple
when a  ame is present. When no  ame is present, no signal
is sent and the magnet releases closing the check valve.
Because no gas can  ow through the valve if the pilot is not
burning, no gas can build up, decreasing the risks a of any
safety conditions.
Thermocouple
The thermocouple is positioned so that the tip of the
thermocouple comes into contact with the pilot  ame
when lit. When exposed to a  ame, a properly functioning
thermocouple produces a small electrical signal measured
in millivolts. This signal is transferred through the electrical
wire connecting the thermocouple to the safety valve in
the SIT control, and to the magnet inside the valve thereby
energizing it. Again, when the magnet is energized, it is able
to hold a check valve in an open state allowing gas to  ow
through the valve to the burner(s) and pilot(s). If the pilot
goes out then the generation of millivolts stops and the
magnet in the safety valve releases to close o the supply
gas.
Pilot
The pilot provides the  ame that the thermocouple uses to
generate millivolts. When all three of the above components
are placed together a Flame Failure system is created.
The above principles apply no matter what section of the
range is using  ame failure technology. When operating
open top burners or hot tops the hi-lo valve also acts as a
safety valve in the system. The same SIT thermostat as in the
oven section of the range is used on  at griddle models.
Burner Operation
Caution: In the event that a binding or malfunctioning
valve, or thermostat control is observed DO NOT light the
pilots or continue operation until an authorized service
technician has inspected the appliance. Failure to do so
may result in injury.
Open Top burners
Lighting
1. Push in the valve knob, and turn it counter clockwise to
the ignition
position.
2. While holding the valve knob fully in, light the pilot
burner with a match or BBQ ignition device.
Note: On ranges equipped with electric spark igniters, press
the igniter button and check that the pilot lights. Should
burner ignition fail within 4 seconds, turn the burner valve
o and repeat steps 1 through 2. If ignition continues to fail,
consult the factory authorized service agency.
3. When the pilot is lit continue to hold the valve knob fully
in for at least 30 seconds, then release it. If the pilot goes
out, wait for (5), minutes, then repeat from step 1.
4. When the pilot remains lit, push the valve in again and
turn it counter-clockwise to the desired  ame setting
position, lighting the burner.
OPERATION
Part # 4525587 Rev 4 (29 April 14) Page 15
Shut Down
1. To turn the burner o and still have the pilot remain on,
turn the dial to the ignition position.
2. To turn the burner and pilot o , turn the dial to the
circular “OFF” symbol. The safety device will disengage
within 60 seconds.
Hot Tops and Front-Fired Target Tops
Lighting
1. Push in the valve knob, and turn it counter clockwise to
the ignition position.
2. While holding the valve knob fully in, press the igniter
button and observe if the pilot lights. If it does not light,
repeatedly depress the igniter button until it does.
Note: On ranges equipped with electric spark igniters, press
the igniter button and check if the pilot lights. Should burner
ignition fail within 4 seconds, turn the burner valve o and
repeat steps 1 through 2. If ignition continues to fail, consult
the factory authorized service agency.
3. When the pilot is lit continue to hold the valve knob fully
in for at least 30 seconds, then release it. If the pilot goes
out, wait for (5), minutes, then repeat from step 1.
4. When the pilot remains lit, push the valve in again and
turn it counter-clockwise to the desired  ame setting
position, lighting the burner.
5. For low  ame or simmer push in the valve knob and turn
it counter-clockwise to the low  ame position.
6. Surface plates are capable of reaching very high
temperatures, solid hot tops 380C(716F) front - red
target tops 585C(1085F).
Shut Down
1. To turn the burner o and still have the pilot remain on,
turn the dial to the ignition position.
2. To turn the burner and pilot o , turn the dial to the
circular “OFF” symbol. The safety device will disengage
within 60 seconds.
Ovens (Standard)
Lighting
1. Lower front kick panel below oven door, raise oven
hearth bottom for easy access to oven pilot.
2. Turn oven control knob ( gure 1) to position and
then push in to engage the  ow of gas through the safety
device to the pilot.
Figure 1
3. While holding knob in, light pilot with a match/BBQ
lighter or use the spark ignition (if provided) to spark
ignite pilot.
4. Continue to hold knob in for 15 seconds after ignition,
then release. Pilot should remain lit.
5. If pilot burner fails to light or does not stay lit, wait 5
minutes and repeat steps 2 through 4.
6. Replace hearth or close kick panel, then turn oven
thermostat to desired cooking temperature.
7. To shut down main burner turn control knob ( gure 1) to
position.
Warning: Use caution when opening the oven door while it
is in use. Hot air or steam may cause injury.
Shut Down
If pilot shut down is required push in oven thermostat knob
and turn to symbol. The system will disengage with in 60
seconds.
OPERATION Continued
Part # 4525587 Rev 4 (29 April 14)Page 16
OPERATION Continued
Convection Ovens
The forced air range oven consists of a food preparation
chamber completely sealed from the combustion area.
This eliminates the possibility of contamination from  ue
products and permits an e cient method of circulating the
heated air within the cooking chamber.
During the cooking process in a conventional oven, a vapor
barrier and a layer of cool” air covers the exposed area of
the product. In a forced air oven, the fan pushes the heated
air over and around the product, sweeping away the vapor
barrier and cool air, permitting faster heat penetration. This
action permits the use of lower temperatures and shorter
cooking times.
The rule of thumb for determining the cooking temperature
is to reduce the set temperature by approximately
80°F, (28°C), from that which you would set in a conventional
oven. The product should be checked at a point midway in
the time required in a conventional oven.
Lighting
1. Lower front kick panel below oven door.
2. Push and hold in oven thermostat control valve knob
( gure 1) and turn it counter clockwise to the ignition
position “ ”.
3. While holding knob fully in depress the red igniter button
and observe that the pilot  ame is lit. If it does not light,
repeatedly depress the igniter button until it does.
Note: On ranges equipped with electric spark igniters, press
the igniter button and check if the pilot lights. Should burner
ignition fail within 4 seconds, turn the burner valve o and
repeat steps 1 through 2. If ignition continues to fail, consult
the factory authorized service agency.
4. When the pilot is lit, continue to hold the valve knob fully
in for 15 seconds, then release it. If the pilot goes out, wait
for  ve (5) minutes, then repeat steps 2 to 4.
Start Up
1. Set the power switch to the COOK” position.
2. Turn the thermostat to the desired setting.
Cool down
1. Turn the oven valve knob to the position this will
prevent the main oven burner from cycling on. ( gure 1).
2. Turn the thermostat to its lowest setting.
3. Open the oven door.
Warning: Use caution when opening the oven door while it
is in use. Hot air or steam may cause injury.
4. Set the power switch to the COOL DOWN” position.
5. Once the oven has cooled turn the power switch to o
and close the oven door.
Shut Down
1. If pilot shut down is required push in oven thermostat
knob turn to symbol. The system will disengage with
in 60 seconds.
2. Power switch should be in the o position.
Operating Suggestions
The motor in your range convection oven is maintenance
free since it is constructed with self-lubricating sealed ball
bearings. It is designed to provide durable service when
treated with ordinary care. We have a few suggestions to
follow for the care of your motor.
A. When the motor is operating, it cools itself internally by
air entering the rear of the motor case, provided proper
clearance has been allowed.
B. Since the blower wheel is in the oven cavity it is at the
same temperature as the oven. If the motor is stopped
while the oven is hot, the heat from the blower wheel is
conducted down the shaft and into the armature of the
motor. This action could shorten motor life.
C. We recommend, at the end of the bake or roasting
period, when the oven will be idle for any period of time
or before shutting down completely, that the doors
be left open, and by use of the cool-down position on
the fan switch, the fan continues to run for at least 20
minutes. The “FAN” should never be turned “OFF” when
the oven section is in use.
Part # 4525587 Rev 4 (29 April 14) Page 17
OPERATION Continued
D. All convection oven model units have a controllable
moisture vent. The vent control is a sliding cover inside
the oven cavity. Sliding the vent from left to right will
increase or decrease the amount moisture inside the
oven during cooking. Dryness or moisture of the  nished
product will dictate the setting of the vent. To speed up
pre-heat time close the vent during preheat.
Thermostat Controlled Griddles
See griddle seasoning before use.
1. For general thermostat griddle lighting instructions
please refer to the section entitled “OVEN (STANDARD)”
above. (Steps 2 though 7)
2. Pilots should be lit though the front panel with an extend
match or long BBQ lighter. If necessary the front panel of
the range can be removed to allow the griddle plates to
be raised at the front, block securely.
3. Light pilots located at the front left side of each burner
4. The sensing bulbs must be fully inserted into their
individual holders, which are located on the underside
of the griddle. To check griddle burner  ame set the
thermostat to its maximum setting and then return to
pilot.
5. If the griddle has been raised to light the pilots, lower
carefully into position, being very careful not to leave any
part of the capillary tube in the burner compartment.
Replace the front panel of the range.
6. Surface temperature of solid griddle top is capable of
reaching at least 265C (509 F).
Caution: Only authorized service
technicians should be removing thermostat
control knobs. In the event the thermostat
temperature knob has been removed, the set
screw must line up with the hole on the
thermostat control dial.
Griddle/Broiler
See griddle seasoning before use.
Lighting
1 Push in the valve knob, and turn it counter clockwise to
the ignition position.
2 While holding the valve knob fully in, press the igniter
button and check if the pilot lights. If it does not,
repeatedly depress the igniter button until it does.
Note: On ranges equipped with electric spark igniters, press
the igniter button and check that the pilot lights. Should
burner ignition fail within 4 seconds, turn the burner valve
o and repeat steps 1 through 2. If ignition continues to fail,
consult the factory authorized service agency.
3. When the pilot is lit continue to hold the valve knob fully
in for at least 30 seconds, then release it. If the pilot goes
out, wait for (5), minutes, then repeat from step 1.
4. When the pilot remains lit, push the valve in again and
turn it counter-clockwise to the desired  ame setting
position, lighting the burner.
5. For low  ame or simmer push in the valve knob and turn
it counter-clockwise to the low  ame position.
6. Surface Temperature of solid griddle top is capable of
reaching at least 380C (716 F).
Shut Down
1. To turn the burner o and still have the pilot remain on,
turn the dial to the ignition position.
2. To turn the burner and pilot o , turn the dial to the
circular “OFF” symbol. The safety device will disengage
within 60 seconds.
Range Shut down
1. Turn all valves to the “OFF” position.
2. If the unit is to be shut down for an extended period of
time, close the in-line gas valve.
Part # 4525587 Rev 4 (29 April 14)Page 18
General
The range is the workhorse of the kitchen because of its
versatility. Most frequently used in small applications, such as
cafes, schools, church kitchens,  rehouses, and small nursing
homes where demands are less taxing. As a general rule of
thumb, one four to six burner range with a hot top will be
adequate for a restaurant seating 30 to 35.
The top of the range is designed for  exibility and the
preparation of numerous medium volume types of products.
It may be equipped with two, or even three di erent types
of tops and burners, depending on the menu needs. An
operation that cooks to order, or uses the range primarily
as back-up will  nd that open burners will suit most of their
needs.
Preparation of soups, stocks, or sauces is done on a hot top
where slow, even cooking is desirable.
Heating larger quantities of food can be done more
e ciently than heating small quantities. Pots and pans
should be covered whenever possible to reduce energy
consumption.
High acid sauces, such as tomato should be cooked in
stainless steel rather than aluminum to avoid chemical
reaction. Light colored sauces such as Alfredo may be
discolored by the use of aluminum, especially if stirred with
a metal spoon or whip. Saltwater shell sh may pit aluminum
pots if they are frequently used for this purpose.
Use appropriately sized pots and pans to  t each burner. Do
not allow pots to overhang plate rail.
Crumb Trays
In the event of a grease  re in the crumb tray, call a service
technician to inspect for possible damage to components.
Do not continue to operate unit until inspected by
authorized service agent.
NOTE: Many parts of the commercial range are raw steel.
Hot tops, griddles, springs, door hooks etc., can react with
moisture forming rust. This occurrence is normal and not
considered a defect. Clean with a stainless steel or  ber pad.
A light coating of cooking oil may be applied.
CAUTION: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS
APPLIANCE WHILE IT IS IN OPERATION.
Open Burners
The most traditional uses of open burners are sautéing, pan
frying, and small stock pot work. Short-term cooking is the
most e cient use for the open burner. Pans should cover
as much of the grate as possible to minimize heat loss. The
maximum stock pot size to be used on an open burner is
12 inches, (305mm), diameter. Use a pan size large enough
to contact all of the grate supports (minimum 6 , 150mm).
Open burners should be turned o when not in use to
conserve energy. Leaving a  ame burning is of no advantage
since the heat is instantaneous.
Hot Tops
Use of the solid hot tops is recommended where long-term
stock pot cooking is required for soups, sauces or stock. Pots
can be placed anywhere on the hot tops. Recommended
pre-heat time is 30 minutes. This will ensure that the casting
is thoroughly saturated with heat. Pots have should  at
bottoms for maximum surface contact. Warped or dented
pots will not transfer heat evenly, wasting energy and
resulting uneven cooking patterns. During slow periods, it is
advisable to lower the burner setting to conserve energy.
PRODUCT APPLICATION INFORMATION
Part # 4525587 Rev 4 (29 April 14) Page 19
MAINTENANCE AND CLEANING
Seasoning
Griddle
A. Remove all factory applied protective material by
washing with hot water, mild detergent or soap solution.
B. Apply a thin coat of cooking oil to the griddle surface,
about one ounce per square foot of griddle surface.
Spread over the entire griddle surface with a cloth to
create a thin  lm. Wipe o any excess oil with a cloth.
C. Light all burners, set at the lowest possible setting. Some
discoloration will occur when heat is applied to steel.
D. Heat the griddle slowly for 15 to 20 minutes. Then wipe
away oil. Repeat the procedure 2 to 3 times until the
griddle has a slick, mirror like  nish.
IMPORTANT: Do not set to a high position (on valve control)
or 450° (on thermostat control) during “break-in period.
NOTE: Steel griddle surface will tone (blue discoloration)
from heat. This toning will not diminish function or operation
and it is not a defect.
The griddle will not require reseasoning if it is used properly.
If the griddle is over heated and product begins to stick to
the surface it may be necessary to repeat the seasoning
process again. If the griddle is cleaned with soap and water it
will be necessary to reseason the griddle surface.
Cast Iron top Grates
First, remove the cast iron top grates from the range. Wash
the cast iron top grates thoroughly with a mild soap and
warm water. Dry the cast-iron top grates thoroughly with a
clean cloth. Immediately after drying, season the top grates
lightly with a non-toxic oil, (Liquid vegetable oil or Pam spray
oil) WARNING; DO NOT SEASON THE TOP GRATES WHILE ON
THE RANGE TOP! Seasoning grates on the range top over an
open  ame could cause a  ash re. After seasoning, replace
the top grates onto the range. Turn all the range top sections
“ON LOW. Allow the top sections to burn in this manner
for at least 20 minutes before using pots or pans on the top
grates. SEASONING OF THE TOP GRATES WILL BE REQUIRED
WHENEVER THEY HAVE BEEN CLEANED. FAILURE TO SEASON
GRATES WILL CAUSE RUSTING.
Stainless Steel
For routine cleaning, wash with a hot water and detergent
solution. Wash just a small area at a time or the water will
evaporate leaving the chemicals behind causing streaking.
Rinse the washed area with a clean sponge dipped in a
sanitizing solution and wipe dry with a soft clean cloth
before it can dry.
Use a paste (of water and a mild scouring powder) if you
have to, but never rub against the grain. All stainless steel has
been polished in one direction. Rub with the polish lines to
preserve the original  nish. Then thoroughly rinse as before.
To prevent  ngerprints there are several stainless steel
polishes on the market that leave an oily or waxy  lm. Do not
use on surfaces that will be in contact with food.
Stainless steel may discolor if overheated. These stains can
usually be removed by vigorous rubbing with a scouring
powder paste.
Use only stainless steel, wood or plastic tools if necessary
to scrape o heavy deposits of grease and oil. Do not use
ordinary steel scrapers or knives, as particles of the iron may
become imbedded and rust. NEVER USE STEEL WOOL.
Either a typical bleach solution or hot water can be used to
sanitize stainless steel.
Oven Interior (Porcelain Enamel)
NOTE: Disconnect line cord (if applicable) from power supply
before cleaning or servicing.
1. Before cleaning oven interior, remove all oven racks
and guides (if “RC base). Oven racks and guides can be
cleaned with a mild soap and warm water or run through
dish washer.
2. The porcelain interior can be cleaned with oven cleaners
such as “Easy O , or “Dow Oven Cleaner”.
Follow product manufacturer’s instructions for proper use.
Open Top Burners
Cleaning of the range top burner is a simple procedure, and,
if done at regular intervals will prolong the life of the range
and ensure good  ame characteristics.
1. The most common problem with open burner ranges is
spillage. Once the burner ports are partially plugged with
food, the air-to-gas mixture is disturbed and results in an
ine cient burner.
2. Wipe any spills as they occur.
3. Grids and trays should be removed daily, washed, rinsed
and dried thoroughly.
Part # 4525587 Rev 4 (29 April 14)Page 20
4. Use a wire brush to clean the ports of the burners. Ignite
and check for clogged holes.
5. If any clogged holes are apparent, the burner should be
lifted out and brushed inside and out with a small Venturi
brush. Each port on the burner itself should be cleaned
with a properly sized wire or thumb drill. Wash with soap
and hot water if grease is observed on the burners. Dry
thoroughly.
6. When reinstalling the open top burner head be sure
the burner ports are lined up correctly to the pilot. On
the cast burner head there is a raised indicator arrow to
ensure the burner is installed correctly.
RAISED ARROW INDICATOR
PILOT
7. If an abnormal  ame appears around the edges, it is
usually a sign of grease or dirt in the throat of the burner.
Remove the burner venturi (main body that the burner
heads sit on) to access the air shutter opening. Remove
grease and dirt from the air shutter area carefully. Do
not adjust the shutter setting. The air shutter allows the
proper amount of air to mix with the  ow of gas coming
in from your valve/thermostat ori ce and should not be
adjusted unless by a licensed gas  tter technician.
Cast Iron Top & Grates
Cast iron top and grate(s) can be cleaned with mild soap
and warm water. For baked on material, a wire brush can be
used. Dry thoroughly. Lightly coat with vegetable oil to help
prevent rust from forming.
Hot Tops and Front-Fired Target Hot Tops
While the surface is still slightly warm, wipe down with a
clean burlap cloth. Burnt on spillage should be scraped o . If
necessary, remove the plate and wash in a sink with soap and
hot water. Dry thoroughly. In damp climates, wipe down with
a light coating of oil to prevent rusting. Avoid excessive use
of water as this could damage the surface and the controls
below.
CAUTION: Do not use water on top plates while they are hot
or Do not use ice to cool plates.
NOTE: Hot top and front- red target hot top surface will
“tone (blue/brown discoloration) from heat. This toning will
not diminish function or operation and is not a defect.
Griddle
To produce evenly cooked, browned griddle products, keep
griddle free from carbonized grease. Carbonized grease on
the surface hinders the transfer of heat from the griddle
surface to food product. This results in uneven browning
and loss of cooking e ciency, and worst of all, carbonized
grease tends to cling to grilled foods, giving them a highly
unsatisfactory and unappetizing appearance. To keep the
griddle clean and operating at peak performance, follow
these simple instructions:
A. AFTER EACH USE clean griddle thoroughly with a grill
scraper or spatula. Wipe o any excess debris left from
cooking process.
B. ONCE A DAY clean griddle surface with a grill brick and
grill pad. Remove grease container and clean thoroughly,
in the same manner as any ordinary cooking utensil.
C. ONCE A WEEK clean griddle surface thoroughly. If
necessary, use a grill stone or grill pad over the griddle
surface. Rub with grain of the metal while still warm.
A detergent may be used on the plate surface to help
clean it, but care must be taken to be sure it is thoroughly
removed. After removal of detergent, the surface of the
plate should be covered with a thin  lm of oil to prevent
rusting. To remove discolorations, use a non-abrasive
cleaner. Before re-using, the griddle must be reseasoned.
Keep griddle drain tube to grease container clear at all
times.
CAUTION This griddle plate is steel, but the surface is
relatively soft and can be scored or dented by careless use of
a spatula.
Be careful not to dent, scratch, or gouge the plate surface.
This will cause food to stick in those areas. Also, note, since
this is a steel griddle if a light coating of oil is not always
present rust will develop on exposed and uncoated areas.
MAINTENANCE AND CLEANING Continued
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Garland 36ER33-88 Owner Instruction Manual

Catégorie
Fours
Taper
Owner Instruction Manual

dans d''autres langues