Cumberland Smart Climate 32 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Please scan the QR Code to access the complete
manual or visit the website.
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
WIRING DIAGRAM
SMART CLIMATE 32
#891-00500 REV 02
REV 05
EN
STAGE 5 STAGE 4 IN2 V1 IN1`
L2/N
L
{
GND
L1
L2 ( N )
ON-OFF
{
GND
L1
L2 ( N )
ON-OFF
V2V3
VARIABLE
VARIABLE
CLO OPN IN WINCH
RETURN
45 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K LM N O P
1
A
2
B
3
C
PC1
PC2
OUT +
OUT -
PMV-1
G 1
PMV-2
1 2 3 4G
HUMIDITY
SENSOR (Old model)
STATIC
PRESSURE
SENSOR
DWYER GAUGE
{
ALARM
NC
C
NO
{
0-10V +
0-10V -
0-10V +
0-10V -
WATER METER
(OPTIONAL)
(NOT INCLUDED)
(stage 2) (stages 1&3)
(OPTIONAL)
CONTROLLER
POWER SUPPLY
230 VAC (115 VAC)
STAGE 4
POWER SUPPLY
230 VAC (115 VAC)
STAGE 2
POWER SUPPLY
230 VAC (115 VAC)
STAGE 1 & 3
POWER SUPPLY
230 VAC (115 VAC)
STAGE 5
POWER SUPPLY
230 VAC (115 VAC)
FAN STAGE 2 MAX. OUTPUT 10 AMP.
FAN STAGE 1 MAX. OUTPUT 10 AMP.
THERMOSTAT
BACKUP*
FAN/HEATER/MIST STAGE 4 MAX. OUTPUT 10 AMP.
FAN/HEATER/MIST STAGE 5 MAX. OUTPUT 10 AMP.
FAN STAGE 3 MAX. OUTPUT 10 AMP.
VARIABLE
{
GND
L1
L2 (N)
{
GND
L1
L2 (N)
{
GND
L1
L2 (N)
ON/OFF Ouput Capacity:
115VAC 1/4HP (187W), 230VAC 1/2HP
(373W), 7.5 Amp Res. Max.
We recommend installing external relays
on "on/off" stages hooked to motors.
Fuse Box:
We recommend installing a
fuse box on each stage.
Cable Entry:
Punch holes at the bottom
of the enclosure to allow
wires to be introduced in the
controller. Do not drill the
top or side panels of the
enclosure.
The water meter output
should be a dry contact and
should not pulse faster than
60 times a second (60 Hz).
A 22/12 AWG gauge cable
no longer than 2000 feet
(0.6 km) can be used to
connect the water meter.
Do not use a cable longer
than 2000 feet even if a
larger cable is used.
Do not run the meter
cable outside the building !
*Backup Thermostats:
The backup thermostats are
shown for illustration
purposes only. Sufficient
backup thermostats must
be used to ensure
ventilation if the controller
loses power.
Water Meter:
Notes:
1. Installation of a good
quality alarm system is
strongly suggested to warn
of power failures and
high/low temperatures.
2. Provide a surge
protection (including
lightning protection) from
the power supply to the
controller and from the
control to the sensors.
Consult a certified
electrician if required.
3. Same phases must be
used to power the variable
fans and the controls on 3
phases power.
Coil
N.O.
N.O.
COM
COM
{
{
Coil power source
Stage output
from control
to distribution panel
stage input
Variable Output Capacity:
115VAC 1/2HP (373W),
230VAC 1.5HP (1120W), 10 Amp Max.
Actuator (winch): Open/Close output,
120VAC(0.17HP 124W), 240VAC
(0.5HP 373W), 30 VDC 5A Ind.
12"
Mounting the Enclosure
on the Wall:
230 V
115/230 VAC
VOLTAGE SELECTOR
0-10V
output
#2
0-10V
output
#1
PC Communication
port. Insert a
Comlink-1 or
Enabler card
(see next page).
J2 Connector Connection
for top board
To communication system
(see next page)
Sensors (see overleaf)
Potentiometer
(see overleaf)
Actuator (see overleaf)
Relative humidity
sensor HS-1
(Optional)
1 2 3 4
Leave a clearance of at least 12”
above controller to allow the cover
to be removed for maintenance.
WIRING DIAGRAM
SMART CLIMATE 32
#891-00500 REV 02
EN
N - + GL FILTER
CLO OPN IN WINCH
RETURN
{
L1
GND
N
+18VAC
-18VAC
POTENTIOMETER
(1, 5 or 10 Kohms, 10 Turns)
ACTUATOR
ACTUATOR
POWER SUPPLY
230 VAC (115 VAC)
CLO OPN IN WINCH
RETURN
L1
{
GND
L2
( N )
T
T
T
T
CLOSE
OPEN
MOVING GND (WIPER)
OUTSIDE
CLOSE
OPEN
ACTUATOR
POWER
SUPPLY
115 VAC
18 TO 36 VDC
TRANSFORMER
ACTUATOR
{
CLO OPN IN WINCH
RETURN
L1
{
GND
N
T
T
T
T
POTENTIOMETER
BLACK
RED
YELLOW
18AWG
SHIELDED
CABLES
ACTUATOR
POWER SUPPLY
115 VAC
CLOSE
OPEN
Von Weise Actuator V-76-115
115 VAC Motor with potentiometer
(1, 5 OR 10 Kohms, 10 Turns)
OUTSIDE
WHITE *
BLUE (MOVING GND WIPER) *
ORANGE
INSIDE T∞ SENSOR #1
INSIDE T∞ SENSOR #2 (OPT.)
INSIDE T∞ SENSOR #3 (OPT.)
INSIDE T∞ SENSOR #4 (OPT.)
OUTSIDE T∞ SENSOR (OPT.)
INSIDE T∞ SENSOR #1
INSIDE T∞ SENSOR #2 (OPT.)
INSIDE T∞ SENSOR #3 (OPT.)
INSIDE T∞ SENSOR #4 (OPT.)
OUTSIDE T∞ SENSOR (OPT.)
THE RESISTANCE
INCREASES
ON 13 & 14
WHEN OPENING
CLO OPN IN WINCH
RETURN
T
T
T
T
OUTSIDE
RED
BLACK
INSIDE T∞ SENSOR #1
INSIDE T∞ SENSOR #2 (OPT.)
INSIDE T∞ SENSOR #3 (OPT.)
INSIDE T∞ SENSOR #4 (OPT.)
OUTSIDE T∞ SENSOR (OPT.)
L1
{
GND
( N )
ACTUATOR
POWER SUPPLY
115 VAC
WHITE
GREEN
with potentiometer (1, 5 OR 10 Kohms, 10 Turns)
YELLOW (POT. WIPER)
18AWG
SHIELDED
CABLES
THE RESISTANCE
INCREASES
ON 13 & 14
WHEN OPENING
*
IT IS IMPORTANT TO
CONNECT THE
TERMINAL
WITH THE ACTUATOR
WINCH
RETURN
IT IS IMPORTANT TO
CONNECT THE
TERMINAL
WITH THE ACTUATOR
WINCH
RETURN
BLACK
RED
IT IS IMPORTANT TO
CONNECT THE
TERMINAL
WITH THE ACTUATOR
WINCH
RETURN
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K LM N O P
POTENTIOMETER
(1, 5 or 10 Kohms, 10 Turns)
T
T
T
T
MOVING GND (WIPER)
OUTSIDE
INSIDE T∞ SENSOR #1
INSIDE T∞ SENSOR #2 (OPT.)
INSIDE T∞ SENSOR #3 (OPT.)
INSIDE T∞ SENSOR #4 (OPT.)
OUTSIDE T∞ SENSOR (OPT.)
18AWG
SHIELDED
CABLES
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K LM N O P
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
VIC JACK ACTUATOR- AC MOTOR
VIC JACK ACTUATOR
18AWG
SHIELDED
CABLES
WIRING DIAGRAM
SMART CLIMATE 32
#891-00500 REV 02
EN
A B GND
A B GND
1 2 3
A B GND
A B GND
1 2 3
EOL = no*
[PC line]
Red
Black
Shield
Connector A
SURELINK MODULE
A-BOX Communication
System Hook-up (Optional)
AgNet Communication
System Hook-up (Optional)
* Refer to the
Surelink manual to
set the end of line
jumpers (EOL) of
the PC
communication line
properly
EOL = Yes
[PC line]
NO YES
END OF LINE
1 2 3 4 Tx Rx G L N G
7654321
Modem or
computer
Red
Green
White
Computer or modem
BRIDGE-A
1
END OF LINE
2 3
EOL = Yes
[PC line]
EOL = yes*
[PC line]
PC
I J
PC1
PC2
HG
OUT-
MAIN CONTROLLER
ENABLER CARD
PC
I J
PC1
PC2
HG
MAIN CONTROLLER
COMLINK-1 CARD
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
SCHÉMA DE BRANCHEMENT
SMART CLIMATE 32
#891-00500 REV 02
REV 05
FR
Veuillez scanner le code QR pour accéder aux
manuels complets ou visiter le site Web.
1 2 3 4
STAGE 5 STAGE 4 IN2 V1 IN1`
L2/N
L
{
GND
L1
L2 ( N )
ALIMENTATION
STAGE 4
230 VAC (115 VAC)
ON-OFF
{
GND
L1
L2 ( N )
ALIMENTATION
STAGE 5
230 VAC (115 VAC)
ON-OFF
VENT./ARRO./CHAUFF. STAGE 5 SORTIE 10 AMP. MAX.
VENT./ARRO./CHAUFF. STAGE 4 SORTIE 10 AMP. MAX.
V2V3
CLO OPN IN WINCH
RETURN
45 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K LM N O P
1
A
2
B
3
C
PC1
PC2
OUT +
OUT -
PMV-1
G 1
PMV-2
1 2 3 4G
SONDE
D’HUMIDITÉ (Ancien modèle)
SONDE
PRESSION
STATIQUE
DWYER GAUGE
{
ALARME
NC
C
NO
{
0-10V +
0-10V -
0-10V +
0-10V -
COMPTEUR D’EAU
(OPTIONNEL)
DE SECOURS*
(NON-INCLUS)
THERMOSTAT
(stage 2) (stages 1&3)
(OPTIONNEL)
VARIABLE
VARIABLE
ALIMENTATION
CONTRÔLEUR
230 VAC (115 VAC)
ALIMENTATION
STAGE 2
230 VAC (115 VAC)
ALIMENTATION
STAGE 1 & 3
230 VAC (115 VAC)
VENT. STAGE 2. SORTIE 10 AMP. MAX
VENT. STAGE 1. SORTIE 10 AMP. MAX
VENT. STAGE 3. SORTIE 10 AMP. MAX
VARIABLE
{
GND
L1
L2 (N)
{
GND
L1
L2 (N)
{
GND
L1
L2 (N)
12"
Fixation du contrôleur au mur :
Coil
N.O.
N.O.
COM
COM
{
{
Alimentation bobine
Stage sortie
du contrôle
au panneau de distibution électrique
stage entrée
Capacité des sorties marche-arrêt :
115VAC 1/4HP (187W), 230VAC 1/2HP
(373W), 7.5 Amp Res. Max.
Il est reommandé d’installer des relais
externes sur les stages marche-arrêt reliés
aux moteurs
Disjoncteurs :
Il est recommandé de
raccorder chaque sortie de
stage à un disjoncteur séparé.
Entrée des câbles :
Passer tous les câbles sous le
boîtier. Ne pas percer de
trous sur les côtés ou sur le
dessus du boîtier pour éviter
les infiltrations d'eau.
Ne pas faire courir le câble
du compteur d’eau à
l’extérieur du bâtiment !
*Thermostats de secours :
Les thermostats de secours
sont montrés à titre
d’exemple. Utilisez
suffisamment de thermostats
de secours pour assurer la
ventilation en cas de
défaillance du contrôleur.
Compteur d’eau :
La sortie du compteur d’eau
doit être un contact sec et ne
doit pas pulser plus
rapidement que 60 fois la
seconde (60 Hz).
Un câble de calibre 22/12
AWG ne dépassant pas 2000
pieds (0,6 km) peut être utilisé
pour raccorder le compteur
d’eau.Ne pas utiliser un câble
plus long que 2000 pieds
même si le câble utilisé est
plus gros.
Notes :
1. L’installation d’un système
d’alarme est fortement
recommandée afin de
détecter les pertes de courant
et les hautes/ basses
températures.
2. Des protecteurs de
surtension sont recommandés
entre l’alimentation, le
contrôleur et les sondes.
Consulter un électricien au
besoin.
3. Lors d’une alimentation 3
phases, les mêmes phases
doivent être utilisées pour
alimenter les ventilateurs
variables et le contrôleur.
Capacité des sorties variables :
115VAC 1/2HP (373W), 230VAC 1.5HP
(1120W), 10 Amp Max.
Actuateur (treuil) : sortie d’ouverture et de
fermeture, 120VAC(0.17HP 124W), 240VAC
(0.5HP 373W), 30 VDC 5A Ind.
CONNECTEUR J2
Port de
communication PC.
Insérer une carte
“Comlink-1” ou une
carte “Enabler”
(voir page suivante)
Connecteur
du couvercle
Branchement des
sondes : voir au verso
Branchement du
potentiomètre :
voir au verso
Branchement de
l’actuateur:
voir au verso
115/230 VAC
Sélecteur de
tension
Vers système de communication
(voir page suivante)
230 V
Charge
0-10V
n°2
Charge
0-10V
n°1
Sonde d’humidité
relative HS-1
(Optionnel)
Laisser un espace libre d’au moins
12 pouces au-dessus du contrôleur
pour permettre de soulever le
couvercle et d’effectuer un entretien.
SCHÉMA DE BRANCHEMENT
SMART CLIMATE 32
#891-00500 REV 02
FR
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
JAUNE
NOIR
ROUGE
POTENTIOMÉTRE
{
Actuateur Von Weise V-76-115
Moteur 115 VAC avec potentiomètre
(1, 5 ou 10 Kohms, 10 tours)
BLANC
BLEU (CONTACT MOBILE)
ORANGE
N - + GL FILTRE
TRANSFORMATEUR
18 Â 36 VDC
ACTUATEUR
CLO OPN IN WINCH
RETURN
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
ACTUATEUR
L1
{
GND
L2
( N )
ALIMENATION DE
L'ACTUATEUR
230 VAC (115VAC)
POTENTIOMÉTRE
(1, 5 ou 10 Kohms, 10 tours)
CÂBLES
BLINDÉS
18AWG
CLO OPN IN WINCH
RETURN
CLO OPN IN WINCH
RETURN
L1
{
GND
N
ALIMENTATION
ACTUATEUR
115 VAC
FERMER
OUVRIR
ALIMENTATION
ACTUATEUR
115 VAC
{
L1
GND
N
T
T
T
T
T°EXT
T
T
T
T
T°EXT
+18VAC
-18VAC
FERMER
OUVRIR
FERMER
OUVRIR
POTENTIOMÉTRE
(1, 5 ou 10 Kohms, 10 tours)
CÂBLES
BLINDÉS
18AWG
T
T
T
T
T°EXT
CÂBLES
BLINDÉS
18AWG
ACTUATEUR VIC JACK : MOTEUR AC
LA RÉSISTANCE
AUGEMENTE
SUR 13 ET 14
EN OUVERTURE
CLO OPN IN WINCH
RETURN
ROUGE
NOIR
L1
{
GND
( N )
BLANC
VERT
T
T
T
T
T°EXT
JAUNE (CONTACT MOBILE)
NOIR
ROUGE
ALIMENTATION
ACTUATEUR
115 VAC
ACTUATEUR VIC JACK
avec potentiomËtre (1, 5 OU 10 Kohms, 10 Tours)
IMPORTANT :
BRANCHER CORRECTEMENT
LE BORNIER
À L’ACTUATEUR
WINCH
RETURN
IMPORTANT :
BRANCHER
CORRECTEMENT
LE BORNIER
À L’ACTUATEUR
WINCH
RETURN
IMPORTANT :
BRANCHER
CORRECTEMENT
LE BORNIER
À L’ACTUATEUR
WINCH
RETURN
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
4 5 6 7 8 9 10 11 12 13 14 15 16
D E F G H I J K L M N O P
CÂBLES
BLINDÉS
18AWG
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SMART CLIMATE 32
#891-00500 REV 02
FR
SCHÉMA DE BRANCHEMENT
A B GND
A B GND
1 2 3
A B GND
A B GND
1 2 3
EOL = non*
[Ligne PC]
Rouge
Noir
Blindage
Connecteur A
MODULE SURELINK
* Se référer au
manuel
díutilisation du
module Surelink
pour régler les
cavaliers de fin de
ligne (EOL)
NON OUI
FIN DE LIGNE (EOL)
1 2 3 4 Tx Rx G L N G
7654321
Ordinateur
ou modem
Rouge
Vert
Blanc
Ordinateur ou modem
BRIDGE-A
1 2 3
EOL = oui*
[Ligne PC]
PC
I J
PC1
PC2
HG
OUT-
CONTRÔLEUR
PRINCIPAL
CARTE “ENABLER”
PC
I J
PC1
PC2
HG
CARTE “COMLINK-1”
Branchement de la communication
pour A-BOX (optionnel)
Branchement de la communication
pour AgNet (optionnel)
EOL = oui
[Ligne PC]
CONTRÔLEUR
PRINCIPAL
EOL = oui
[Ligne PC]
FIN DE LIGNE (EOL)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Cumberland Smart Climate 32 Le manuel du propriétaire

Taper
Le manuel du propriétaire