STI 1210 Sounder Strobe Manuel utilisateur

Taper
Manuel utilisateur
STI-1210E SPEAKER HORN/STROBE DAMAGE STOPPER®
All specications and information shown were current as of publication and are subject to change without notice.
INSTALLATION NOTES
1. To minimize strobe light loss, regardless of the type of horn/
strobe appliance used, the clear section (not the section
containing the cutout slots) must be centered over the strobe
light lens. Failure to follow these instruction may lead to light
loss transmission.
2. Damage Stopper must be installed to comply with applicable
NEC, NFPA and local codes.
3. In applications where wash downs, rainfall or condensation
occur, it is recommended that a drain or weep hole be
provided. Refer to weep hole installation diagram.
4. Damage Stopper may be installed outdoors when appliance
carries an outdoor rating.
1210EIS APRIL2006
CLEANING INSTRUCTIONS
Rinse with water to remove abrasive dust and dirt. Wash with soap or mild
detergent, using a soft cloth (do not scrub). Rinse once more then dry with
a soft cloth or chamois. To remove grease or wet paint, rub gently with a
cloth wetted with naphtha. Then wash and rinse. DO NOT USE RAZOR
BLADES.
INSTALLATION INSTRUCTIONS - REFER TO EXPLODED VIEW
1. Using enclosure assembly as a template, place against mounting surface at proper location
according to NFPA 72.
2. Mark and drill (4) holes 1/4 in. (6.3mm) diameter, 1 in. (25mm) deep.
3. Insert the (4) anchors into the wall.
4. Mount frame assembly to wall with screws.
5. Install electrical ttings as needed.
6. Install horn/strobe appliance (except for retrot applications).
7. Install cover with clips and screws.
8. Test appliance according to appliance manufacturer’s instructions.
INTERNAL DIMENSIONS
H629764 CLAMP
(4) PROVIDED
SCREW #10 x 1 1/2 in.
(4) PROVIDED
ANCHOR
(4) PROVIDED
APPROX
CENTER LINE
OF UNDERSIDE OF
COVER
1 in.(25mm)
HEIGHT
8.5 in.(216mm)
DEPTH
4 in.(102mm)
WIDTH
6.5 in.(165mm)
12
IF ADDED PROTECTION IS
NEEDED DUE TO ENVIROMENTAL
CONDITIONS ORDER KIT-121
ENVIRO KIT
EXISTING
FLUSH MOUNT
HORN/ STROBE
APPLIANCE
!
LOCATED IN THIS AREA
DRILL A 1/4 in.(6.3mm) DI A. HOLE
#8-32 x 3/8 in.
SOCKET HEAD CAP SCREW
(4) PROVIDED
KIT-06297E FRAME ASSY.
CLEAR
SECTION
M01210 COVER ONLY
M01210 COUVERCLE SEULEMENT
INSTALL CLAMP IN 2nd. NOTCH AS SHOWN
H629764 CLAMP
(4) PROVIDED
SCREW #10 x 1 1/2 in.
(4) PROVIDED
ANCHOR
(4) PROVIDED
APPROX
CENTER LINE
OF UNDERSIDE OF
COVER
1 in.(25mm)
HEIGHT
8.5 in.(216mm)
DEPTH
4 in.(102mm)
WIDTH
6.5 in.(165mm)
12
IF ADDED PROTECTION IS
NEEDED DUE TO ENVIROMENTAL
CONDITIONS ORDER KIT-121
ENVIRO KIT
EXISTING
FLUSH MOUNT
HORN/ STROBE
APPLIANCE
!
LOCATED IN THIS AREA
DRILL A 1/4 in.(6.3mm) DI A. HOLE
#8-32 x 3/8 in.
SOCKET HEAD CAP SCREW
(4) PROVIDED
KIT-06297E FRAME ASSY.
CLEAR
SECTION
M01210 COVER ONLY
M01210 COUVERCLE SEULEMENT
INSTALL CLAMP IN 2nd. NOTCH AS SHOWN
H629764 CLAMP
(4) PROVIDED
SCREW #10 x 1 1/2 in.
(4) PROVIDED
ANCHOR
(4) PROVIDED
APPROX
CENTER LINE
OF UNDERSIDE OF
COVER
1 in.(25mm)
HEIGHT
8.5 in.(216mm)
DEPTH
4 in.(102mm)
WIDTH
6.5 in.(165mm)
12
IF ADDED PROTECTION IS
NEEDED DUE TO ENVIROMENTAL
CONDITIONS ORDER KIT-121
ENVIRO KIT
EXISTING
FLUSH MOUNT
HORN/ STROBE
APPLIANCE
!
LOCATED IN THIS AREA
DRILL A 1/4 in.(6.3mm) DI A. HOLE
#8-32 x 3/8 in.
SOCKET HEAD CAP SCREW
(4) PROVIDED
KIT-06297E FRAME ASSY.
CLEAR
SECTION
M01210 COVER ONLY
M01210 COUVERCLE SEULEMENT
INSTALL CLAMP IN 2nd. NOTCH AS SHOWN
H629764 CLAMP
(4) PROVIDED
SCREW #10 x 1 1/2 in.
(4) PROVIDED
ANCHOR
(4) PROVIDED
APPROX
CENTER LINE
OF UNDERSIDE OF
COVER
1 in.(25mm)
HEIGHT
8.5 in.(216mm)
DEPTH
4 in.(102mm)
WIDTH
6.5 in.(165mm)
12
IF ADDED PROTECTION IS
NEEDED DUE TO ENVIROMENTAL
CONDITIONS ORDER KIT-121
ENVIRO KIT
EXISTING
FLUSH MOUNT
HORN/ STROBE
APPLIANCE
!
LOCATED IN THIS AREA
DRILL A 1/4 in.(6.3mm) DI A. HOLE
#8-32 x 3/8 in.
SOCKET HEAD CAP SCREW
(4) PROVIDED
KIT-06297E FRAME ASSY.
CLEAR
SECTION
M01210 COVER ONLY
M01210 COUVERCLE SEULEMENT
INSTALL CLAMP IN 2nd. NOTCH AS SHOWN
WEEP HOLE INSTALLATION
REMARQUES SUR L’INSTALLATION
1. An de minimiser la perte de lumière stroboscopique, quel que soit le type d’alarme sonore/de stroboscope utilisé, la section dégagée (et NON
la section contenant les fentes de découpe), doit être centrée sur l’objectif stroboscopique. Le fait d’omettre ces instructions risque d’entraîner
la perte de diffusion de la lumière.
2. Le Stopper de dégâts doit être installé de sorte à être conforme avec les normes NEC, NFPA applicables et les codes locaux.
3. Dans les applications où des jets d’eau, des précipitations ou de la condensation se produisent, il est recommandé de prévoir un trou de
vidange ou une barbacane. Reportez-vous à schéma d’installation d’une barbacane.
4. Il est possible d’installer un Stopper de dégâts à l’extérieur lorsque l’appareil est homologué pour utilisation à l’extérieur.
WARNING: This product can expose you to chemicals including Dichloromethane,
which is known to the State of California to cause cancer, and Bisphenol A (BPA),
which is known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
Three year warranty or a one year limited warranty (from date of purchase) on most products.
See website for details. Electronic warranty form at www.sti-usa.com/wc14.
INSTALL CLAMP IN 2nd. NOTCH AS SHOWN
USA EMEA
This enclosure is rated to protect signaling appliances indoors and in areas of indirect weather
exposure. The cover may be used outdoors only with devices also suitable for outdoor use.
When covering fire-signaling appliances with this enclosure, some light and sound loss occurs.
Please follow these guidelines listed during installation.
Voice speaker appliance: No spacing adjustment is required for 0.5W, 1.0W and 2.0W appliances.
Refer to the appliance manufacturer's candela rating. Multiply this number by the light loss value
from the chart below to determine the new candela rating. Use this number and refer to the
notification layout table of NFPA 72 for proper device locations.
The use of this cover on audible devices decreases the sound output by 6dB(A). Actual sound level
output should be checked after installation to determine if adequate sound levels exist. Refer to the
notification layout table of NFPA 72 for proper device locations.
Performance Review - LIGHT DERATING FACTOR
MANUFACTURER SERIES STI-1210 STI-1221/1221A4X MANUFACTURER SERIES STI-1210 STI-1221/1221A4X
UL INSTALLATION REQUIREMENTS
STI-1210 / STI-1221 SERIES
04/2006
CAUTION
Ce boîtier est homologué pour protéger les appareils de signalisation d’incendie à l’intérieur et dans les
zones d’exposition indirecte aux intempéries. Le couvercle ne peut être utilisé à l’extérieur qu’avec les
appareils appropriés pour une utilisation à l’extérieur aussi.
Le fait de couvrir les appareils de signalisation d’incendie au moyen de ce boîtier risque d’entraîner une
certaine perte lumineuse et sonore. Veuillez vous conformer à ces directives lors de l’installation.
Haut-parleur: Aucun ajustement de distance n’est nécessaire pour les appareils à tension de 0,5 W, 1,0 W et
2,0 W.
• Reportez-vous à la cote candéla du fabricant de l’appareil. Multipliez cette valeur par la valeur de la perte
de lumière du tableau ci-dessous pour déterminer la nouvelle cote candéla. Utilisez cette nouvelle valeur
et reportez-vous au tableau de disposition des alertes de la norme NFPA 72 pour les emplacements
appropriés de l’appareil.
L’utilisation de ce couvercle sur les dispositifs sonores diminue la puissance sonore de 6 dB(A). Le niveau
réel de la sortie sonore doit être vérifié après l’installation pour déterminer le maintien de niveaux sonores
adéquats. Reportez-vous au tableau de disposition des alertes de la norme NFPA 72 pour les
emplacements appropriés de l’appareil.
Attention
STI-1210 Series Sound Derating Factor: System Sensor P2, PC2, P4, PC4, SX, SC series models: 6.7 dBA, General: 6 dBA
STI Generic Light Loss Value: STI-1210 Series: 53%; STI-1221 Series: 61%
SAFETY TECHNOLOGY INTERNATIONAL • www.sti-usa.com • www.sti-emea.com
HONEYWELL XLS202 SERIES 43% 45%
HONEYWELL XLSG1-HV SERIES 40% 34%
HONEYWELL XLSG1-HOV SERIES 40% 34%
MIRCOM FS-240 47% 26%
MIRCOM MS SERIES 43% 45%
MIRCOM MG1-V SERIES 40% 34%
MIRCOM MG1-HV SERIES 40% 34%
MIRCOM MG1-HOV SERIES 40% 34%
MIRTONE MG1-V SERIES 40% 34%
NATIONAL TIME & SIGNAL GES24 SERIES 31%
POTTER ELECTRIC AS-24-153075R 47% 26%
POTTER ELECTRIC AS-24-153075W 47% 26%
SECUTRON GES24 SERIES 31%
SIEMENS 202- SERIES 43% 45%
SIEMENS G1-V SERIES 40% 34%
GENTEX GES24 SERIES 31%
SYSTEM SENSOR SS24110ADA 47% 37%
SYSTEM SENSOR P2, PC2, P4, PC4, SX, SC 53% 61%
ZITON PTY LTD ZG1-V SERIES 40% 34%
ADT SECURITY ADTG1-V SERIES 40% 34%
AMSECO SL24W-153075 47% 26%
AMSECO - COLORED LENSES SL24W-153075 A, B, G, OR R 47% 26%
AMSECO - COLORED LENSES SL24C-3075110 A, B, G, OR R 47% 26%
AMSECO - COLORED LENSES CSL24W-A, B, G, OR R 47% 26%
AMSECO - COLORED LENSES CSL24C-A, B, G, OR R 47% 26%
DETECTION SYSTEMS GES24 SERIES 31%
EST/EDWARDS 2440S SERIES 43% 45%
EST/EDWARDS 202 SERIES 43% 45%
EST/EDWARDS G1-V SERIES 40% 34%
EST/EDWARDS G1-HV SERIES 40% 34%
EST/EDWARDS G1-HOV SERIES 40% 34%
EST/EDWARDS EG1-V SERIES 40% 34%
EST/EDWARDS EG1-HV SERIES 40% 34%
EST/EDWARDS EG1-HOV SERIES 40% 34%
FARADAY LLC 2700 57%
GENTEX GES24 SERIES 31%
HARRINGTON SIGNAL GES24 SERIES 31%
HONEYWELL XLSG1-V SERIES 40% 34%
  • Page 1 1
  • Page 2 2

STI 1210 Sounder Strobe Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues