Daintree Networked WMZ10 People Counting Sensor Guide d'installation

Taper
Guide d'installation
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 1 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
Installation Guide
WMZ10 | DT050
Daintree® Wireless
People Counting Sensor
(WMZ10)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
WARNING / AVERTISSEMENT
RISK OF ELECTRICAL SHOCK
• Turn power off before inspection, installation or removal.
• Follow all NEC and local codes.
• Do not make or alter any open holes in an enclosure of wiring
or electrical components during kit installation.
• Wear safety glasses and proper aid during installation and
maintenance.
• Install this kit only in the luminaires that has the construction
features and dimensions shown in the photographs and/or drawings.
• Above ceiling access required.
• While the sensor is designed to withstand Electrostatic Discharge
(ESD), it is always advisable to touch a grounded metal object
before handling the sensor, particularly in an operating xture.
RISQUES D’INCENDIE OU DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Respectez tous les codes NEC et codes locaux.
• Ne pas percer ou altérer les trous d’un boitier contenant lou composant électrique
durant l’installation.
• Porter des lunettes de sécurité et les aides appropriéeslors de l’installation et de
l’entretien.
• Installez ce kit uniquement dans les appareils d’éclairagequi a les caractéristiques
de la construction et les dimensions indiquées dans les photographies et/ou dessins.
• Accès requis au-dessus du plafond.
• Bien que le capteur soit conçu pour résister aux décharges électrostatiques (ESD),
il est toujours conseillé de toucher un objet métallique mis à la terre avant de
manipuler le capteur, en particulier dans une installation en fonctionnement.
The WMZ10 is part of the Daintree Networked product portfolio,
an open networked wireless controls solution to address evolving
environmental regulations and transform spaces into intelligent
environments for buildings of all sizes. The WMZ10 utilizes the
Daintree Networked for dimmable light luminaire control, daylight
harvesting, occupancy detection and non-camera based people
counting. The WMZ10 is capable of advertising BLE beacons in
the iBeacon format for enabling Indoor Positioning Solutions.
WARNING
RISK OF ELECTRIAL SHOCK. Disconnect power before service,
installation or maintenance of the product.
WARNING
RISK OF INJURY. Wear safety glasses and gloves during installation
and servicing.
WARNING
RISK OF FIRE. Follow all relevant IEC or UL instructions and local
building codes
Save These Instructions
These instructions do not purport to cover all details or variations in
components nor to provide for every possible contingency to be met
in further information be desired or should particular problems arise
which are not covered sufciently for the purchasers purpose, the
matter should be referred to Current. Current does not claim liability
for any installation not performed according to this guide or not by a
qualied electrician.
CONTACT FACTORY for details and limitations when seeking to
add this device to a luminaire being used with an emergency
system other than Battery Backup.
Electrical Requirements
In case of power supply miswiring, mains can be
present on the device. Make sure all electricity is
switch off before inspection.
Grounding Requirements
In case of power supply miswiring, mains can be
present on the device. Make sure all electricity is
switch off before inspection.
Avoidance of Electrostatic Discharge
While the sensor is designed to withstand Elec-
trostatic Discharge (ESD), it is always advisable to
touch a grounded metal object before handling
the sensor, particularly in an operating xture.
Preparing Electrical Wiring
1
ESD
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
FCC/ IC Compliance Statements
2
Installation/Mounting
3
IMPORTANT
To ensure the product warranty is valid, please ensure all
installation instructions and environmental conditions for storage
and operation are complied with. Only Current trained contractors
can install the product.
This device complies with the part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operations.
This device contains license-exempt transmitter(s)/receivers(s)
that comply with Innovation, Science and Economic Development
Canada’s license-exempt RSS(s). Operation is subject to the
following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference
that may cause undesired operations of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent
appareil est conforme aux CNR d´Innovation, Sciences et
Développement économique Canada applicables aux appareils
radio exempts de licence. L´exploitations est autorisée aux deux
conditions suivantes:
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le
fonctionnement.
To satisfy FCC-ISED RF exposure requirements a separation
distance of 20 cm or more must be maintained between the
antenna of this device and persons during operation.
Operation at closer than 20 cm is not permitted.
Pour être conforme aux limites d’expositon aux ondes RF des
normes FCC/ISED, une distance de séparation d’au moins 20 cm
doe être maintenue entre l’antenne de cet appareil et toute
personne pendant son operation. Mettre en operation ced
appareil a une distance plus rapprochée que 20 cm n’est pas
permis.
• WMZ10 Can be mounted into a 7/8” hole directly in a drywall
ceiling, or drop ceiling tile.
• Ribbed wings hold the sensor in place to the ceiling.
• Recommended Mounting Height is 9’-11’
NOTE:
• All cables are CMP
(Plenum) rated.
• Identication sticker labels are to be placed on or near luminaire
and on a oor plan for mapping
Installation/Mounting
4
The sensor shall be installed and commissioned by a trained
individual.
• Please note, that the sensor shall be installed with the arrow
(on lens) facing North.
• It is important that the sensors are all oriented in the same
direction to ensure optimal performance.
Mounting Height Max. Coverage (sq. ft.)
964 (8 ft. x 8 ft. Square)
10 81 (9 ft. x 9 ft. Square)
11 100 (10 ft. x 10 ft. Square)
Wireless People
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
Installation/Spacing
5
Installation/Orientation
6
Reporting
7
In order to effectively count occupants in the room, the sensors
must be spaced uniformly in a grid pattern.
If working in a room with drop ceilings, the grid must correspond
with the ceiling tiles.
Each sensor has a 4’ max eld of view on each side. Distances
between sensors and IEEE numbers must be recorded.
Ex. 2’x4’ Ceiling Tiles
• People Counting Reporting is provided in the Insights > Zones
section of Daintree Controls Software (DCS) in the Daintree
Networked Wireless Controls platform. For more information
on DCS or Daintree Networked, visit LED.com.
Wiring
8
• Each WMZ10 sensor has an arrow embossed on the sensors
face. This Arrow must be oriented in a known direction.
• We recommend the arrow on each sensor in a room be pointed
AWAY from the wall with the door or entryway.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 4 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
SENSOR ACCESSORY INSTALLATION STANDALONE UNIT (NO LED FIXTURE)
FOLLOW OPTION A OR B FOR NON ENCLOSED OR ENCLOSED INSTALLATION
9
A
DISCONNECT POWER
B
VERIFY POWER SUPPLY AND SENSOR
ARE COMPATIBLE
C
MAKE ELECTRICAL CONNECTIONS
D
CEILING INSTALLATION (SEE OPTION A OR B)
E
TM MULTI-SENSOR ORIENTATION MARK
F
TM MULTI-SENSOR ORIENTATION REQUIREMENT
Remove power by switching circuit breaker to the off position.
Current Lighting Solutions, LLC LED
COMPATIBLE
POWER
SUPPLY
(WMZ10 only)
OR LCA KIT
COMPATIBLE
POWER SUPPLY
(WMZ10 only)
OR LCA KIT
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 5 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
10
A
Identify sensor model
installed
B
Remove sensor from ceiling or LED
SENSOR PLACEMENT
IDENTIFY SENSOR MODEL INSTALLED
C
Install replacement sensor xture
11
TROUBLESHOOTING - Planning Deployment
Obstacles to Avoid
Sprinkler heads, lighting, re alarms, and HVAC registers must be
designed around.
Note:
* Identication sticker labels are to be placed on or near luminaire and on a oor plan for mapping.
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 6 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
12
TROUBLESHOOTING - What to Document
15
PRODUCT CERTIFICATIONS
13
TECHNICAL DATA
14
PRODUCT AVAILABILITY
SKU Descriptions Model
93106832 Wireless People Counting Sensor WMZ10
Product Specictions:Product Specictions:
Sensor Type People counting, occupancy
Dimensions See dimensioned diagram
Weight 0.016 kg
Voltage Rating 9.5-24 VDC, Class 2 (See note below)
Current
Consumption 50mA
Operating Ambient
Temperature Range 0-50°C (Indoor)
Status Indicator LED pattern indicates network join status
Connections See connection diagram
Mounting Hole Installs within a 22mm (0.87”) hole
Recommended
Mounting Height
9-11 ft; Recommended to be spaced 8 ft
apart on the x,y grid
Warranty 5 years
Additional Information:Additional Information:
Purpose of the
Control Operating Control
Method of
Mounting
Control
Independently Mounted Control. Model
WMZ10 intended for ush mounting into
a recessed cavity.
Type of Action and
Additional Features Type 1
Control Pollution
Degree 2
Function/Software
Class and Structure Class A
ORated Impulse
Voltage 330V
Note: I Connect WMZ10 to Current LED drivers or control modules
capable of providing greater than 15VA power, including but not to
models listed in the Power Supply Compatibility List (see page 7).
Note: Any external cables connected to devices not to exceed 30
meters length.
FCC ID: 2AS3F-WMZ10
IC: 25008-WMZ10
• Locations and relative distance of sensors
• Orientation of sensors
• IEEE number of sensors
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 7 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
16
PRODUCT DIMENSIONS
18
POWER SUPPLY COMPATIBILITY LIST
Connect the WMZ10 Sensor to a compatible power supply
using the provided connector.
While the sensor is designed to withstand Electrostatic Discharge
(ESD), it is always advisable to touch a grounded metal object
before handling the sensor, particularly in a operating xture.
Note: Refer to power supply amperage rating to ensure the quantity of WMZ sensors does not exceed power supply amperage.
Manufacturer Manufacturer
P/N
Input Voltage
(VAC)
Output Voltage
(VDC) WMZ10
Current WA100 120-277 VAC 24 VDC Compatible
Current WGA100 120-277 VAC 24 VDC Compatible
Wattstopper BZ-50 120-277 VAC 24 VDC Compatible
Current LCACBA0TWUNGALV 120-277 VAC 12-20 VDC Compatible
Current GEMOD/DB010 120-277 VAC DA Output 16 VDC Compatible
Current GED22MCRP500 120-277 VAC DA Output 16 VDC Compatible
Current GED90MCRP1750 120-277 VAC DA Output 16 VDC Compatible
Current GED100MCC2P480 120-277 VAC DA Output 16 VDC Compatible
Note: Dimensions shown in mm.
17
WIRING DIAGRAM
Daintree® Wireless People Counting Sensor (WMZ10) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 8 of 8
(Rev 6/19/23)
DT050-Daintree-WMZ10-People-Counting-Install-Instructions_R01
CAUTION
The user is cautioned that changes or modications not expressly approved by the party responsible for compliance could
void the users authority to operate the equipment.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met in connection with installation, operation
or maintenance. Should further information be desired or should particular problems arise which are not covered sufciently for the purchaser’s purposes, the matter should
be referred to Current.
FOR STANDALONE SENSOR ACCESSORIES THE FOLLOWING STATEMENTS APPLY
Any changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains license-exempt
transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the
following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. Lexploitation est autorisée aux deux conditions suivantes:
1. Lappareil ne doit pas produire de brouillage;
2. Lappareil doit accepter tout brouillage radio électrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to a part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to a radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced ratio/TV technician for help.
To satisfy FCC/ISED RF exposure requirements a separation distance of 20 cm or more must be maintained between the antenna of this device and persons
during operation. Operation at closer than 20cm is not permitted.
Pour satisfaire aux exigences d’exposition RF FCC/ISED, une distance de séparation de 20 cm ou plus doit être maintenue entre l’antenne de cet appareil et
les personnes pendant le fonctionnement. Une opération à moins de 20 cm n’est pas autorisée.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Daintree Networked WMZ10 People Counting Sensor Guide d'installation